Sterilization pouches. Instructions for Use

Similar documents
OMAN November 2nd 2006 Middle East WFHSS Workshop

ESTEEM AUTOCLAVE SLIDING SINGLE DOOR:-

Best Practice Guidelines For Cleaning, Disinfection and Sterilization of Critical and Semi-critical Medical Devices

SterilContainer S for use in the Steris V-PRO 60 Low Temperature Sterilization System

AMSCO STERILIZATION CONTAINER SYSTEM User s Guide

CLEANING AND HANDLING OF WRIGHT INSTRUMENTS

SBS Design Considerations for Autoclave Sterilization

Packing. Euronda Spa t (+39) m euronda.com

Key Operator Test Study Guide

When you successfully complete the test, you will receive a certificate and a registered key ring. We look forward to hearing from you.

KEY OPERATOR STUDY GUIDE

KEY OPERATOR STUDY GUIDE

AZTECA A LITRE STERILISER

Features. QuickStart. V1505/GameSaver Pro. Features of Your FoodSaver Appliance. Accessory Hose Storage. Accessory Hose.

STERITITE INSTRUCTIONS FOR USE

Presentation Purpose

Purpose. Team Roles and Responsibilities. System Requirements. Instrument Processing Training

KEY OPERATOR. Study guide TRAINING SERIES ANDERSEN PRODUCTS, LTD. Key Operator Training Kit The power of knowledge. the future of gas sterilisation

KEY OPERATOR. Study guide TRAINING SERIES ANDERSEN PRODUCTS, LTD. Key Operator Training Kit. The power of knowledge. the future of gas sterilisation

Features. QuickStart. Professional III/GameSaver Turbo. Features of Your FoodSaver Appliance. Accessory Hose Storage (under lid) Manual Seal Button

VACUUM TECHNOLOGY ENGINEERING

Cardinal Health Ultra-Low Freezers. Protecting your samples requiring ultra-low storage

Healthmark Steriking Price List Fax:

SELF-ADHESIVE FILM INSTALLATION GUIDE

FLASH PAK STERILIZATION CONTAINER SYSTEM

SteelcoSure Independent performance verification of your equipment and processes

Accessories. Maybachstraße. Symmetry Fax: Revised 10/15

Horsehead Holding Corporation Relies on XR-5

BASELINE P 100. Chamber machine. 290 x 205 x 90 mm

2. Occupational safety / Security Waste disposal/waste, disposal bags

3 AND 4-SIDED POUCHES

Washer Test Kits User Guide

One-Side Clear Active Barrier Packaging for Moisture Sensitive Medical Devices:

Vacuum Bonding of Safety and Architectural Glass Laminates

Advance Autoclave. Designed to give you more for your money with a high capacity for faster throughput: More features and benefits...

SPECIAL SPECIFICATION 3687 Impermeable Liner

RG1,5SA Self Adhesive

Current Sterilisation Process Content of the Presentation. Content of the Presentation. Prof (Col) Dr RN Basu. Content

Tips. Tips for Successful Vacuum Packaging. Tips on Sealing a Bag. Tips on Removing Air from a Bag. Tips on Storage

Device Reprocessing Checklist Scoring Matrix 1=low 5=high

OPERATION & MAINTENANCE MANUAL

Advance Autoclave. Designed to give you more for your money with a high capacity for faster throughput: More features and benefits...

Introduction of American Fuji Seal. Shutaro Kurosawa American Fuji Seal, Inc. 4/24/2014

Pouch Cell Li-ion Batteries Pilot Line

LabClave.Com OPERATION & MAINTENANCE MANUAL. Horizontal Autoclave Model: Z-LABCLAVE-01-1 S/N

Policy # MI_WASH Department of Microbiology. Page Quality Manual TABLE OF CONTENTS APPENDIX I STERILIZATION AND GLASS WASHING TECHNICAL MANUAL...

FLANGED CORR/GUARD CORR/GUARD INSTALLATION INSTRUCTIONS

V-PRO LOW TEMPERATURE STERILIZATION SYSTEMS

Medical Silicone & TPE Tubing

INSTALLATION INSTRUCTIONS FOR. 230/240 VAC, 1ø, 50Hz 473X3 SERIES RV ROOF TOP AIR CONDITIONER

Enthermics. Blanket Fluid Warmers TO-B-WARM ISO 13485:2003 Certified MEDICAL SYSTEMS

ESFR PENDENT SPRINKLER VK500 (K14.0) TECHNICAL DATA

HEDMAN The HEDMAN Company 189 Gordon St. Elk Grove Village, IL

SERRES SUCTION BAG SYSTEM MANUAL

TECHNICAL DATA NOTICE

Model KBF 1020 Constant climate chambers with large temperature / humidity range

User Manual for AirFlow Convection Oven

CXD Vacuum Sealing Machines, Oxygen & Moisture Barrier Films, Pouches & Related Products and Equipment.

CLEANING INSTRUCTIONS

For the sterilization of pharmaceutical products using the hot water cascade system.

Series 3 + Thank you for using the EOGas 3 sterilization system.

It s all about choices. High volume High production High consistency Increased efficiency Innovation

Application note. LCD Module. Precautions for LCM handling. LCM handling V 1.1

METHODOLOGY FOR TESTING PERSONAL

Manuel Guide Lighting Fixtures

SPIDER P SPIDER P mineral

Aesculap Implant Systems

RELIABLE. The Midmark M9 and M11 UltraClave Automatic Sterilizers - make sterilization reliable and efficient.

Model KMF 720 Constant climate chambers with expanded temperature / humidity range

TECK-40 Series 1000V Class Splice for 4/C Armored Teck Power Cables

Model KBF 240 Constant climate chambers with large temperature / humidity range

GEOSYNTHETICS ENGINEERING: IN THEORY AND PRACTICE

O-PEP Hygiene-Beileger

Biological Incubators Biotech Ovens

Hand Operated Sealers and Foot sealers, impulse and hot bar series.

INSTALLATION GUIDE Induction Cooktops

Aesculap Implant Systems

Syllabus Structure for Certificate Course in

SmartPower Solutions. SmartPower Solutions. Product Data Sheet , Rev AC January Contents

INTRODUCTION. Model ESGO by Evacusled Inc.

Section 714. GEOTEXTILE AND GEOCOMPOSITE DRAIN MATERIAL

* The Cryolock vial and the T310-10A Cryovial have a polyethylene cap.

VACUUM PUMP Micro Cartridge Pump

Note: Make sure you remove all loose fibers and particles since they would generate holes in the image.

The Professional Choice

Vacuum packing From Wikipedia, the free encyclopedia

IMPORTANT NOTICES INSTALLATION INSTRUCTIONS KAWASAKI MULE SX FULL VENT WINDSHIELD (WITH FOLDING UNDER HOOD STORAGE ACCESS) PART #

SMALL DIAMETER CORR/GUARD & SLEEVED CORR/GUARD

Cleaning and Sterilization for Instruments & Posts

KE-Series Constant-Wattage Heating Cable

Model WP-32 Pouch Machine

Operator s Manual CAYENNE HEAT N SERVE 4/3 RECTANGULAR RETHERMALIZER ENGLISH

Proweld Equipment Owner & Maintenance Manual

PACKAGING MACHINES. a General information a Options. a Vertical vacuum chamber a Specification overview. a Band sealers a Diptanks

Low Temperature Sterilisation ISO 14937

Cleaning & Sterilization

FINISHER OR PULPING MACHINE

ESFR PENDENT SPRINKLER VK510 (K25.2) TECHNICAL DATA

00% 100%3HealthCare 00%

esfr dry pendent sprinkler Vk502 (k14.0)

Transcription:

pouches Instructions for Use

Type I: Self-Sealing sterilization pouch Cat. no. Material description Packaging Raw material 92028 Pouch Paper Self Seal 10.5in. x 28in. 100ea/bx; 6bx/cs 92114 Pouch Paper Self Seal 4in. x 11in. 200ea/bx; 4bx/cs 92152 Pouch Paper Self Seal 12in. x 15in. 100ea/bx; 4bx/cs 92168 Pouch Paper Self Seal 8in. x 16in. 200ea/bx; 4bx/cs 92308 Pouch Paper Self Seal 3.5in. x 8.75in. 200ea/bx; 4bx/cs 92309 Pouch Paper Self Seal 3.5in. x 9.875in. 200ea/bx; 4bx/cs 92318 Pouch Paper Self Seal 13in. x 18in. 100ea/bx; 4bx/cs 92322 Pouch Paper Self Seal 3.5in. x 22in. 200ea/bx; 4bx/cs 92510 Pouch Paper Self Seal 5.5in. x 10in. 200ea/bx; 4bx/cs 92515 Pouch Paper Self Seal 5in. x 15in. 200ea/bx; 4bx/cs 92713 Pouch Paper Self Seal 7.5in. x 13in. 200ea/bx; 4bx/cs 92923 Pouch Paper Self Seal 9.125in. x 25.5in. 100ea/bx; 6bx/cs 32115 Pouch Tyvek Self Seal 10in. x 15in. 100ea/bx; 5bx/cs 32218 Pouch Tyvek Self Seal 12in. x 18in. 100ea/bx; 4bx/cs 32307 Pouch Tyvek Self Seal 3in. x 7in. 100ea/bx; 8bx/cs 32409 Pouch Tyvek Self Seal 4in. x 9in. 100ea/bx; 8bx/cs 32412 Pouch Tyvek Self Seal 4in. x 12in. 100ea/bx; 8bx/cs 32422 Pouch Tyvek Self Seal 4in. x 22in. 100ea/bx; 8bx/cs 32610 Pouch Tyvek Self Seal 6in. x 10in. 100ea/bx; 8bx/cs 32812 Pouch Tyvek Self Seal 8in. x 12in. 100ea/bx; 8bx/cs High Performance White Medical Grade Paper Blue Complex Film White High Density Polyethylene (HDPE) Tyvek Transparent Film Steam or ETO 1. Packaging Place items to be sterilized into an appropriate sized pouch. The pouch should only be filled 3/4 of the packing volume to allow proper air evacuation and sterilant penetration. Carefully press the exess air out of the pouch and ensure there is at least one (1) inch between the adhesive strip and items. ETO After removing the protective strip, seal the pouch by folding the adhesive strip onto the pouch. Apply pressure from the center of the adhesive, towards the edges. Repeat this motion an additional time for extra security. If you are using a double pouching, the pouch sizes should be selected so the inner pouch can be placed inside the outer pouch without folding. The inner pouch must also be sealed. The paper side of both pouches should face the same way. For example, paper towards paper and film towards film. 2

2. Loading the sterilizer If you are using several pouches at once, when placing pouches in the sterilizer make sure plastic side of sterilization pouch always faces paper side of adjacent pouch to allow proper air evacuation and sterilant penetration. If possible use a pouch rack to eliminate stacking of the sterilization pouches. Check that pouches are dry upon removal. 3. instructions Please refer to the following recommendations for Steam and ETO sterilization cycles. Parameter Temperature setting Time setting Pressure setting Steam 250ºF (121ºC) 20 minutes 1.2bar 273ºF (134ºC) 4 minutes 2.1bar ETO 129-133ºF (54-56ºC), 50%PH 105 minutes -70KPA 4. Storage Ensure the sterile storage area is well-ventilated and provides protection against dust, moisture, insects and extreme temperature and humidty. pouches should be stored in a cool and dry environment (temperature 59-85ºF; humidity 40-70%). The items should be positioned so that packaging is not crushed, bent, compressed, or punctured so the package integrity is not otherwise compromised. 5. Shelf life Our Pouch and Tubing products have been tested and passed five year accelerated aging testing post sterilization. They were found to have no leaks, and showed no physical damage while stored under controlled storage conditions. 6. Aseptic presentation The sterilized pouch should be peeled off gently and opened slowly from the chevron end. 3

Type II: Heat-Sealing sterilization pouch Cat. no. Material description Packaging Raw material 90168 Pouch Paper Heat Seal 8in. x 16in. 100ea/bx; 9bx/cs 90308 Pouch Paper Heat Seal 3in. x 8in. 200ea/bx; 5bx/cs 90408 Pouch Paper Heat Seal 4in. x 8in. 200ea/bx; 5bx/cs 90411 Pouch Paper Heat Seal 4.5in. x 11in. 200ea/bx; 5bx/cs 90422 Pouch Paper Heat Seal 4in. x 22in. 200ea/bx; 5bx/cs 90515 Pouch Paper Heat Seal 5in. x 15in. 200ea/bx; 5bx/cs 90610 Pouch Paper Heat Seal 6in. x 10in. 200ea/bx; 5bx/cs 90713 Pouch Paper Heat Seal 7.5in. x 13in. 200ea/bx; 5bx/cs 90810 Pouch Paper Heat Seal 8in. x 10in. 200ea/bx; 5bx/cs 91015 Pouch Paper Heat Seal 10in. x 15in. 100ea/bx; 5bx/cs 91218 Pouch Paper Heat Seal 12in. x 18in. 100ea/bx; 5bx/cs 91315 Pouch Paper Heat Seal 13in. x 15in. 100ea/bx; 5bx/cs 91616 Pouch Paper Heat Seal 16in. x 16in. 100ea/bx; 5bx/cs 91822 Pouch Paper Heat Seal 18in. x 22in. 100ea/bx; 5bx/cs 37115 Pouch Tyvek Heat Seal 10in. x 15in. 100ea/bx; 5bx/cs 37218 Pouch Tyvek Heat Seal 12in. x 18in. 100ea/bx; 4bx/cs 37307 Pouch Tyvek Heat Seal 3in. x 7in. 100ea/bx; 10bx/cs 37409 Pouch Tyvek Heat Seal 4in. x 9in. 100ea/bx; 10bx/cs 37412 Pouch Tyvek Heat Seal 4in. x 12in. 100ea/bx; 10bx/cs 37422 Pouch Tyvek Heat Seal 4in. x 22in. 100ea/bx; 10bx/cs 37610 Pouch Tyvek Heat Seal 6in. x 10in. 100ea/bx; 10bx/cs 37812 Pouch Tyvek Heat Seal 8in. x 12in. 100ea/bx; 10bx/cs High Performance White Medical Grade Paper Blue Complex Film White High Density Polyethylene (HDPE) Tyvek Transparent Film Steam or ETO ETO Sealing parameter Sealing temperature is: 334-370ºF (168-188ºC); Sealing pressure is: 0.441-0.637K PA; Sealing time is: 0.8-1.5s Sealing temperature is: 257-266ºF (125-130ºC); Sealing pressure is: 0.343-0.49KP A; Sealing time is: 0.8-1.5s 1. Packaging Place items to be sterilized into an appropriate sized pouch. The pouch should only be filled 3/4 of the packing volume to allow proper air evacuation and sterilant penetration. Carefully press the exess air out of the pouch and ensure there is at least one (1) inch of area available around all four (4) sides of the enclosed items. Seal the pouch with the heat-seal machine according to the appropriate sealing parameters listed in the above chart. All parameters should be validated before using. If you are using a double pouching, the pouch sizes should be selected so the inner pouch can be placed inside the outer pouch without folding. The inner pouch must also be sealed. The paper side of both pouches should face the same way. For example, paper towards paper and film towards film. 4

2. Loading the sterilizer If you are using several pouches at once, when placing pouches in the sterilizer make sure plastic side of sterilization pouch always faces paper side of adjacent pouch to allow proper air evacuation and sterilant penetration. If possible use a pouch rack to eliminate stacking of the sterilization pouches. Check that pouches are dry upon removal. 3. instructions Please refer to the following recommendations for Steam and ETO sterilization cycles. Parameter Temperature setting Time setting Pressure setting Steam 250ºF (121ºC) 20 minutes 1.2bar 273ºF (134ºC) 4 minutes 2.1bar ETO 129-133ºF (54-56ºC), 50%PH 105 minutes -70KPA 4. Storage Ensure the sterile storage area is well-ventilated and provides protection against dust, moisture, insects and extreme temperature and humidty. pouches should be stored in a cool and dry environment (temperature 59-85ºF; humidity 40-70%). The items should be positioned so that packaging is not crushed, bent, compressed, or punctured so the package integrity is not otherwise compromised. 5. Shelf life Our Pouch and Tubing products have been tested and passed five year accelerated aging testing post sterilization. They were found to have no leaks, and showed no physical damage while stored under controlled storage conditions. 6. Aseptic presentation The sterilized pouch should be peeled off gently and opened slowly from the chevron end. 5

Type III: Paper and Tyvek sterilization tubing Cat. no. Material description Packaging Raw material T90002 Tubing Paper 2in. width; 100ft. roll 100ft/roll; 10rolls/cs T90003 Tubing Paper 3in. width; 100ft. roll 100ft/roll; 10rolls/cs T90004 Tubing Paper 4in. width; 100ft. roll 100ft/roll; 10rolls/cs T90006 Tubing Paper 6in. width; 100ft. roll 100ft/roll; 10rolls/cs T90009 Tubing Paper 9in. width; 100ft. roll 100ft/roll; 6rolls/cs T90012 Tubing Paper 12in. width; 100ft. roll 100ft/roll; 6rolls/cs High Performance White Medical Grade Paper Blue Complex Film T37003 Tubing Tyvek 3in. width; 75ft. roll 75ft/roll; 10rolls/cs White High Density T37004 Tubing Tyvek 4in. width; 75ft. roll 75ft/roll; 10rolls/cs Polyethylene (HDPE) Tyvek T37006 Tubing Tyvek 6in. width; 75ft. roll 75ft/roll; 10rolls/cs T37009 Tubing Tyvek 9in. width; 75ft. roll 75ft/roll; 6rolls/cs Transparent Film Steam or ETO 1. Packaging Place items to be sterilized into an appropriate sized pouch. The pouch should only be filled 3/4 of the packing volume to allow proper air evacuation and sterilant penetration. Carefully press the exess air out of the pouch and ensure there is at least one (1) inch of area available around all four (4) sides of the enclosed items. ETO Seal the pouch with the heat-seal machine according to the appropriate sealing parameters listed in the above chart. All parameters should be validated before using. If you are using a double pouching, the pouch sizes should be selected so the inner pouch can be placed inside the outer pouch without folding. The inner pouch must also be sealed. The paper side of both pouches should face the same way. For example, paper towards paper and film towards film. 6

2. Loading the sterilizer If you are using several pouches at once, when placing pouches in the sterilizer make sure plastic side of sterilization pouch always faces paper side of adjacent pouch to allow proper air evacuation and sterilant penetration. If possible use a pouch rack to eliminate stacking of the sterilization pouches. Check that pouches are dry upon removal. 3. instructions Please refer to the following recommendations for Steam and ETO sterilization cycles. Parameter Temperature setting Time setting Pressure setting Steam 250ºF (121ºC) 20 minutes 1.2bar 273ºF (134ºC) 4 minutes 2.1bar EO 129-133ºF (54-56ºC), 50%PH 105 minutes -70KPA 4. Storage Ensure the sterile storage area is well-ventilated and provides protection against dust, moisture, insects and extreme temperature and humidty. pouches should be stored in a cool and dry environment (temperature 59-85ºF; humidity 40-70%). The items should be positioned so that packaging is not crushed, bent, compressed, or punctured so that the package integrity is not otherwise compromised. 5. Shelf life Our Pouch and Tubing products have been tested and passed five year accelerated aging testing post sterilization. They were found to have no leaks, and showed no physical damage while stored under controlled storage conditions. 6. Aseptic presentation The sterilized pouch should be peeled off gently and opened slowly. 7

Type IV: Multiple inner pouch Material no. Material description Packaging Raw material 96004 96008 Pouch multiple inner 4 pouches sheet; 4 inner pouches, 8.9cm width per pouch Pouch multiple inner 8 pouches sheet; 8 inner pouches, 3.8cm width per pouch 100ea/bx; 2bx/cs 100ea/bx; 2bx/cs High Performance White Medical Grade Paper Blue Complex Film Steam or ETO 1. Packaging Place items to be sterilized into an appropriate sized multiple inner pouches. The pouch should only be filled 3/4 of the packing volume to allow proper air evacuation and sterilant penetration. Choose the appropriate pouch or tubing and put the multiple inner pouch within it. The sterilization pouch sizes should be selected so the multiple inner pouch can be placed inside the outer pouch without folding. The paper side of both pouches should face the same way. For example, paper towards paper and film towards film. 2. Loading the sterilizer Please refer to the packaging process for the outer pouch you have selected (e.g. refer to Paper Heat-Seal instructions if using Paper Heat-Seal outer pouch). Make sure plastic side of sterilization pouch always faces paper side of adjacent pouch. If possible, use a pouch rack to eliminate stacking of the sterilization pouches. Check that pouches are dry upon removal. 3. instructions Please refer to the following recommendations for Steam and ETO sterilization cycle. Parameter Temperature setting Time setting Pressure setting Steam 250ºF (121ºC) 20 minutes 1.2bar 273ºF (134ºC) 4 minutes 2.1bar ETO 129-133ºF (54-56ºC), 50%PH 105 minutes -70KPA 4. Storage Ensure the sterile storage area is well-ventilated and provides protection against dust, moisture, insects and extreme temperature and humidty. pouches should be stored in a cool and dry environment (temperature 59-85ºF; humidity 40-70%). The items should be positioned so that packaging is not crushed, bent, compressed, or punctured so the packaging integrity is not otherwise compromised. 5. Shelf life Our Pouch and Tubing products have been tested and passed five year accelerated aging testing post sterilization. They were found to have no leaks, and showed no physical damage while stored under controlled storage conditions. 6. Aseptic presentation The sterilized pouch should be peeled off gently and opened slowly from the chevron end. Distributed by: Cardinal Health Waukegan, IL 60085 USA Rev. D 5/13 cardinalhealth.com Made in China 2013 Cardinal Health. All rights reserved. CARDINAL HEALTH and the Cardinal Health LOGO are trademarks or registered trademarks of Cardinal Health. All other marks are the property of their respective owners.