INSTALLATION, CARE & USE MANUAL

Similar documents
INSTALLATION and USE MANUAL Models (L)VRC8WS, (L)VRC8WSJO Factory Prep ezh2o Bottle Filling Station and Cooler

Installation/Care/Use Manual EZH20 In Wall Bottle Filling Station

Installation/Care/Use Manual EZH20 In Wall Bottle Filling Station

Installation/Care/Use Manual

LZWSRK -EZH2O IMPORTANT

Installation and Use Manual

Installation and Use Manual

EZWSRK -EZH2O IMPORTANT

Halsey Taylor Owners Manual

LZWSRK -EZH2O IMPORTANT

EZ & LZ Series Bottle Filling Stations & Coolers

EZWSRK -EZH2O LZWSRK -EZH2O

Installation/Care/Use Manual

Installation/Care/Use Manual

INSTALLATION, CARE & USE MANUAL VRC8WS, VRC8WSJO, VRCTL8WS, VRCTLR8WS Factory Prep EZH2O Bottle Filling Station and Cooler

Series Barrier-Free Water Coolers

Series Barrier-Free Water Coolers

Cooler Mounted Bottle Fillers

A112408B/S-VR-UBL TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER: Technical Assistance Fax:

VERSAFILLER Model PWEBF (retro fit) and P*EBF Family of Drinking Fountains/VersaFiller. combo Installation Instructions

VERSAFILLER Model PWSBF (retro fit) and P*SBF Family of Drinking Fountains/VersaFiller. combo Installation Instructions

INSTALLATION, OPERATIONS & MAINTENANCE MANUAL A171.8 Series Barrier Free, Wall Mounted Water Cooler

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS Refrigerated Bi-Level, Sensor Operated, AquaAccess Barrier Free, Wall Mounted Water Cooler

Model H1011.8/H1011.8HPS Water Cooler

A172108F-UBL / A172408F-UBL / A172108F-SO / A172408F-SO TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER:

A132.8 Series Barrier Free, Wall Mounted Electric Drinking Fountain

Advanced Two-Stage Drinking Water Filter

Installation & Operation Manual

A171.8 Series Barrier Free, Wall Mounted Water Cooler

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS Sensor Operated AquaAccess Barrier Free, Wall Mounted Water Cooler

C-IV 60 CEILING FAN READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 120V. 60Hz

Retrofit Instructions CLEARVIEW DAY COVER CAUTION: Please read this manual completely before attempting to install, operate or service this equipment

Installation. Leveling

Hanson LED C e i l i n g F a n

Undercounter Refrigeration

A152.8 Series Barrier Free, Bi-Level, Wall Mounted Drinking Fountain

GE Monogram. Installation. Instructions. Stainless Steel Bottom Mount Built-In Refrigerators. Models ZICS36N RH ZICS36N LH

Cooler Mounted Bottle Fillers

SS1095 Ice Maker.

INSTALLATION. Glass Panel Doors (select models) CAUTION

52 CEILING FAN READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V.


GE Monogram. Automatic. Icemaker. Installation Instructions. Models ZDI15 ZDIS15. monogram.com

A171.8-VR & VRB Series Barrier Free, Vandal Resistant & Resistance Button, Wall Mounted Water Cooler

A910.8A Remote Water Chiller, 8 GPH A A / A A-220V TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER:

Installation Instructions

Installation Instructions

Installation Instructions

Installation & Operation Manual

Installation Instructions

Installation Instructions If you have questions, call or visit our website at:

OUTDOOR DRINKING FOUNTAINS OPERATIONS MANUAL

Installation / Care / Use Manual Original Instructions Models: LZSTL8WSL2K, LZSTL8WSS2K, LZSTL8WSVRL2K, LZSTL8WSVRS2K

Electrical cable Water supply tube Fittings for tube Coupler Teflon tape. Hole saw min. 2½" bit

CEILING FAN OWNER'S MANUAL

CEILING FAN OWNER'S MANUAL

Installation Instructions

Vintage Whirlpool Baths: K-702-AC K-702-H-AC CA (9427) Copyright 1994 Kohler Co.

Acrylic Claw Foot Tub

CEILING FAN OWNER'S MANUAL

Water Runs Continuously out of the Bubbler. Water Quality Problem (taste and odor) Water Flow is Intermittent or Erratic

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

Installation. Built-in Full Height Wine Cellar VCWB301

52 Lacey LED. Instruction Manual. 6 Speed DC Wall Control System

INSTALLATION INSTRUCTIONS

Viking Installation Guide

WARNING. Tighten strain relief screws to secure cable. Make sure screw heads are facing up when tightening conduit nut.

Installation. S19-320A (6' cable) S19-320D (12' cable) Flow Switch Alarm System. Table of Contents

DISCONTINUED. Installation. S19-320A (6' cable) S19-320D (12' cable) Flow Switch Alarm System. Table of Contents

READ AND SAVE THESE INSTRUCTIONS

Hourglass Whirlpool Bath: K-1506-H-AB Hourglass Optional Apron: K-1507-AA

1. SAFETY RULES. 8. Avoid placing objects in the path of the blades.

Fountain Classic. Installation and Owner s Manual. Page 16

Stack Kit Installation Instructions For use only with front load washers and dryers

Installation & Operation Manual

FIREPLACE INSTALLATION

CEILING FAN OWNER'S MANUAL

CEILING FAN OWNER'S MANUAL

HE120, HE160 Humidifier Installation Kit

CEILING FAN OWNER'S MANUAL

Infinity Whirlpool Bath: K-1477-V-AB K-1487-V-AB K-1482-V1-AB K-1484-V1-AB

60" Lyndon Patio. Instruction Manual Customer Service :30 AM to 5:00 PM EST, Monday - Friday A Kichler Decor ceiling fan

3MNLR72XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3MNLR72

CEILING FAN OWNER'S MANUAL

CEILING FAN OWNER S MANUAL

WATT R TWIN Energy-Efficient Home Water System

Installation and Operation Manual CLEARVIEW DAY COVER CAUTION: To view a video scan the QR code above

installation and start-up instructions HUMIDIFIERS AND HUMIDISTAT

Installation Instructions

ValkyrieTM. Instruction Manual. Includes our new CoolTouch TM 6 Speed DC Control System Looks permanent, but goes wherever you go! U.S.

PRO 48 INSTALLATION INSTRUCTIONS

Installation Instructions

ESS-2200 Double Station Scrub Sink. with Two Sensor Operated Gooseneck Spout. ESS-3200 Deluxe Double Station Scrub Sink

Bottle Filling Station

MODEL 6430T, 6460 & 6460T POTATO PEELER

Installation Instructions

CEILING FAN OWNER'S MANUAL

DISHWASHER INSTALLATION GUIDE SPECIFICATIONS, INSTALLATION, AND MORE

HE360 Humidifier Installation Kit

LIVIN THE DOG LIFE DRINKING FOUNTAINS INSTALLATION & OPERATION MANUAL

Transcription:

INSTALLATION, CARE & USE MANUAL LVRC8WS, LVRC8WSJO, LVRCTL8WS, LVRCTL8WSJO, Factory Prep EZH2O Bottle Filling Station and Cooler Model LVRC8WS IMPORTANT THIS IS AN INDOOR APPLICATION ONLY. ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON. Model LVRCTL8WS Page 1 98980C (Rev. G - 01/15)

TOOLS REQUIRED BUT NOT PROVIDED: SAFETY GLASSES GLOVES ELECTRIC DRILL 3/4 WRENCH OR CRECENT WRENCH UTILITY KNIFE TAPE MEASURE PENCIL CENTER PUNCH 1/2 SOCKET & RATCHET WRENCH 5/32 ALLEN WRENCH IMPORTANT! INSTALLER PLEASE NOTE. THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO WATER LINES IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM THE BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN, CREATING AN ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE IN THE METAL CONTENT OF THE WATER. THIS CONDITION IS AVOIDABLE BY USING THE PROPER MATERIALS AS INDICATED. ANY DRAIN FITTINGS PROVIDED BY THE INSTALLER SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN FROM THE BUILDING PLUMBING SYSTEM. WE SUGGEST THAT THE BOTTLE FILLING STATION AND WATER COOLER BE PROTECTED BY A GROUND FAULT CIRCUIT INTERRUPTER (GFCI). LVRC8WS Bottle Fillers are among the easiest to install on the market today. To insure you install these models easily and correctly, PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK YOUR INSTALLATION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL, AND OTHER APPLICABLE CODES. After installation, leave these instructions with the Fountain for future reference. 98980C (Rev. G- 01/15) Page 2

49-1/2" 1257mm O 5/16" 8mm MOUNTING HOLES (3 PL) 7" 178mm 16-5/16" 414mm 7" 178mm LVRC8WS 1/4" X 1/2" (6mm X 13mm) OBROUND HOLE (5 PL) 1-1/4" 32mm 1-1/4" 32mm 18-1/2" 470mm 51-1/8" 1298mm 48" 1219mm 2-5/8" 66mm 18-9/16" 472mm HANGER BRACKET E B 4-9/16" 116mm E 33-1/16" 840mm ORIFICE HEIGHT 8" 203mm 31" 788mm 25" 635mm D A 11/16" 18mm 2-1/2" 63mm F 7-1/4" 185mm 2-9/16" 65mm 31-15/16" 811mm RIM HEIGHT C 21-3/8" 543mm 18-3/8" 467mm 5" 127mm 10" 254mm 2-7/16" 63mm 3-1/2" 89mm 4-1/2" 114mm 13-7/8" 352mm * 27" 686mm 12-5/16" 312mm FINISHED FLOOR * REDUCE HEIGHT BY 3 FOR INSTALLATION OF CHILDRENS ADA COOLER LEGEND: A = RECOMMENDED WATER SUPPLY LOCATION 3/8 O.D. UNPLATED COPPER TUBE CONNECT STUB 1-1/2 (38mm) OUT FROM WALL. SHUT OFF VALVE NOT FURNISHED. B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/4 O.D. DRAIN. C = 1-1/4 TRAP NOT FURNISHED. D = ELECTRICAL SUPPLY (3) WIRE RECESSED BOX, DUPLEX OUTLET REQUIRED. E = INSURE PROPER VENTILATION BY MAINTAINING 6 (152mm) MIN. CLEARANCE FROM CABINET LOUVER TO WALL. F = 7/16 BOLT HOLES FOR FASTENING UNITS TO WALL. 5-1/8" 131mm 6-1/4" 159mm 1-1/2" 38mm 6-3/4" 171mm Single Rough-In Fig. 1 Page 3 98980C (Rev. G - 01/15)

1-3/8" 35mm O 5/16" 8mm HOLES (5 PL) 6-1/2" 165mm E 7-1/4" 185mm F 37-1/2" 952mm 5" 127mm 2-9/16" 65mm 20-3/8" 518mm LVRCTL8WS 18-1/16" 459mm 7" 178mm 16-5/16" 414mm 7" 178mm 5-3/4" 146mm 1-3/8" 35mm 5-3/4" 146mm C L 18-1/2" 470mm O 5/16" 8mm HOLES (3 PL) 51-1/8" 1298mm 4-9/16" 116mm C L 10" 254mm 11/16" 18mm 2-7/16" 63mm B 1-1/4" 32mm 6-1/4" 159mm D 3-1/2" 89mm 4-1/2" 114mm 1-1/4" 32mm F A E 13-7/8" 352mm 1/4" X 1/2" (6mm X 13mm) OBROUND HOLE (5 PL) 18-3/4" 476mm 20-1/8" 511mm 25-1/8" 638mm 48" 1219mm 39-9/16" 1005mm ORIFICE HEIGHT 33-1/16" 840mm ORIFICE HEIGHT 31-15/16" 811mm RIM HEIGHT * 27" 686mm FINISHED FLOOR * REDUCE HEIGHT BY 3 FOR INSTALLATION OF CHILDRENS ADA COOLER LEGEND: A = RECOMMENDED WATER SUPPLY LOCATION 3/8 O.D. UNPLATED COPPER TUBE CONNECT STUB 1-1/2 (38mm) OUT FROM WALL. SHUT OFF VALVE NOT FURNISHED. B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/2 O.D. DRAIN. C = 1-1/2 TRAP NOT FURNISHED. D = ELECTRICAL SUPPLY (3) WIRE RECESSED BOX, DUPLEX OUTLET REQUIRED. E = INSURE PROPER VENTILATION BY MAINTAINING 6 (152mm) MIN. CLEARANCE FROM CABINET LOUVER TO WALL. F = 7/16 BOLT HOLES FOR FASTENING UNITS TO WALL. 18-9/16" 472mm 2-5/8" 67mm HANGER BRACKET 8" 203mm C 4-1/8" 105mm 12-5/16" 313mm 5-1/8" 131mm 6-3/4" 171mm Single Rough-In Fig. 1 98980C (Rev. G- 01/15) Page 4

TOP COVER MOUNTING SCREWS BOTTLE FILLER MOUNTING SCREWS DO NOT REMOVE MOUNTING SCREWS DO NOT REMOVE MOUNTING BRACKET FOR FASTENING UNIT TO WALL NOTE: TRIM PLATES MUST BE INSTALLED ON THE INSIDE OF THE BOTTLE FILLER SIDE PANEL SLOTS. WATER COOLER Fig. 3 BOTTLE FILLER INSTALLATION 1) Remove wall mounting plate(s) from Cooler(s). Install Wall Mounting Plate(s) as per rough-in diagrams on sheet 2 or 3 of this instruction. NOTE: Mounting plate(s) MUST be supported securely. Add fixture support carrier if wall will not provide adequate support. 2) For Single Model Installations: Install water cooler onto wall bracket and secure to wall. Connect drain and water inlet to cooler as required (See roughin on page 2). DO NOT connect power to cooler at this time or turn water supply on. 2a) For Two Level Model Installations: Install lower water cooler only at this time onto bracket as per rough-in diagram on sheet 3. 3) Remove VRC Bottle Filler from carton. Remove 3/8 to 1/4 reducing union from end of waterline, (do not throw away it will be needed later). Lay Bottle Filler on water cooler basin and cut insulation from tube even with bottom of unit, remove this insulation from the 3/8 tube, but do not discard. Fish the power cord, and waterline through the hole on top of water cooler. Fish the Reset Button wire from circuit board down through the hole in the basin. NOTE: To prevent scratching the basin place a towel or soft cloth over the entire basin when working above it. 4) With the power cord, waterline and reset button wires through the hole on top of water cooler place Bottle Filler on to mounting bracket on basin. (See Fig. 3). Make sure bottle filler is installed properly on the basin gasket. 5) Once Bottle Filler is installed on basin mounting bracket, tighten the two screws (supplied) one on each side of the bottle filler. Install Top Cover on Bottle Filler (See FIG. 3) with two mounting screws (supplied). Caution do not over tighten screws. 6) For Two Level Model Installations: Secure non-refrigerated unit to wall, connect drains and water inlet. Connect black reset button wires from non-refrigerated unit to the black wires on the refrigerated unit (see step 4). 7) For Single Model Installations: Install remaining tube insulation to the water line from bottle filler, connect Bottle Filler waterline inside of the water cooler by connecting the 3/8 water line with the 3/8 to 1/4 union and short piece of poly tube that was previously installed to the tee at the evaporator outlet. 7a) For Two Level Model Installations: Install the 1/4 poly tubing and insulation from the outlet of the filter to the union on top of the evaporator. Install the 1/4 poly tubing and insulation from the regulator in the non-refrigerated cooler to one of the tees at the evaporator outlet. Install remaining tube insulation to the water line from bottle filler, connect Bottle Filler waterline inside of the water cooler by connecting the 3/8 water line with the 3/8 to 1/4 union and short piece of poly tube that was previously installed to the tee at the evaporator of the refrigerated cooler. 8) Install filter cartridge, remove filter from carton, remove protective cap, attach filter to filter head by firmly inserting into head and rotating filter clockwise. NOTE: If existing plumbing rough-in locations (Drain, Water In, Electric Supply) do not allow the filter to be mounted inside the cooler cabinet the filter can be installed horizontally below the unit. A retrofit kit is available to mount the filter beneath the cooler. 9) Turn water supply on and inspect for leaks. Fix all leaks before continuing. 10) Once unit has been inspected for leaks and any leaks found corrected, plug Bottle Filler and LVRC unit into wall. Be sure to reinstall fuse to the circuit or switch the circuit breaker back to the ON position. 11) Once power is applied to Bottle Filler, the GREEN LED light should illuminate showing good filter status along with the LCD Bottle Counter. 12) Verify proper dispensing by depressing the button at the top of the Bottle Filler and verify water dispenses. Note: the first initial dispenses might have air in line which may cause a sputter. This will be eliminated once all air is purged from the line. 14) Once unit tests out, install Lower Panel back on LVRC water cooler(s). Units are now ready for use. OPERATION OF QUICK CONNECT FITTINGS SIMPLY PUSH IN IN TUBE TO ATTACH TUBE IS SECURED IN IN POSITION PUSH IN COLLET TO RELEASE TUBE Note: Screw the locknut hand tight to seal Fig. 4 A B C PUSHING TUBE IN BEFORE PULLING IT OUT HELPS TO RELEASE TUBE Fig. 5 Page 5 98980C (Rev. G - 01/15)

REMOVAL OF BOTTLE FILLER FOR SERVICING 1) Turn off the water supply to the Water Cooler(s). Unplug and/or turn off Circuit Breaker to Cooler(s) and Bottle Filler. NOTE: the Lower Front Panel of the cooler(s) may need to be removed. To prevent scratching the basin place a towel or soft cloth over the entire basin when working above it. 2) For Single Model Installations: Loosen but DO NOT remove the two (2) Pinned Torx Head Screws from the sides of the Bottle Filler. Remove the two (2) Pinned Torx Head Screws from the Top Cover & remove the Top Cover. The Bottle Filler may then be lifted up and off the Water Cooler (The water line and Remote Reset Button Wires will still be connected from the Water Cooler to the Bottle Filler.). 3) For Two Level Model Installations: Loosen but DO NOT remove the Pinned Torx Head Screw from the outer side of the Bottle Filler and loosen but DO NOT remove the 1/4 hex. head bolt from between the two cooler (See Figs 6 or 7). Remove the two (2) Pinned Torx Head Screws from the Top Cover & remove the Top Cover. The Bottle Filler may then be lifted up and off the Water Cooler (The water line and Remote Reset Button Wires will still be connected from the Water Cooler to the Bottle Filler.). 1/4 HEX. HEAD BOLT THIS LOCATION ONLY STANDARD TWO-LEVEL CONFIGURATION Fig. 6 1/4 HEX. HEAD BOLT THIS LOCATION ONLY STANDARD TWO-LEVEL REVERSED CONFIGURATION Fig. 7 98980C (Rev. G- 01/15) Page 6

VERIFY CONTROL BOARD SOFTWARE 1) To verify the software program of the control board the unit will need to be shut down and restarted. The chiller (if present) does not need to be shut down and restarted. 2) The units lower panel must be open to access the power cord and wall outlet. 3) Shut down the unit by unplugging the power cord from the wall outlet. 4) Restart the unit by plugging the power cord back into the wall outlet. 5) Upon start up the bottle count display will show the software designation of BF9 or BF11. ACCESSING THE PROGRAMMING BUTTON 1) To access the program button remove the bottom cover of the water cooler. The reset button is located on the left side of the cooler near the cold control. Replace the bottom cover after programming operations are completed. NOTE: There is a reset button located under the top cover on the left hand side of the bottle filler also. RESET THE FILTER MONITOR 1) Instructions apply to filtered units only. 2) Depress the program button for approximately 2 seconds until the display changes then release. The display will change and scroll through two messages: RST FLTR Reset Filter Monitor If the program button is not pushed again the display will scroll through the two messages above for three cycles and then default back to bottle count and be back in run mode. 3) When the display changes to RST FLTR, depress the button again. The display will change to show FLT =. Depress the button again and the display will show FLTR =0 4) The Green LED should be illuminated indicating that the visual filter monitor has been reset. BF9 PROGRAM SETTING THE CONTROL BOARD SETTING UNIT TYPE 1) Depress the program button for approximately 2 seconds until the display changes then release. The display will change and scroll through two messages: If the program button is not pushed again the display will scroll through the two messages above for three cycles and then default back to bottle count and be back in run mode. 2) When the display changes to SETTINGS, depress the button again. The display will change to show RNG SET - Range set for IR sensor. UNIT TYP - Type of unit (REFRIG or NON-REFRIG) RST BCNT - Reset bottle count 3) When display shows UNIT TYPE push program button once the display will show current value Can be REFRIG or NON-REFRIG 4) Push button once to change value. Once value is selected the display will show the new value. (Can be REFRIG or NON-REFRIG) REFRIG - stands for refrigerated product. In this setting the flow rate is estimated at 1.0 gallon per minute. NON-REFRIG - stands for non-refrigerated product. In this setting the flow rate is estimated at 1.5 gallons per minute. Both REFRIG and NON-REFRIG simulated 1 bottle equal to 20 oz. 5) Allow approximately 4 seconds to pass and the display will return to bottle counter and be in run mode. RESETTING BOTTLE COUNT 1) Depress the program button for approximately 2 seconds until the display changes then release. The display will change and scroll through two messages: If the program button is not pushed again the display will scroll through the two messages above for three cycles and then default back to bottle count and be back in run mode. 2) When the display changes to SETTINGS, depress the button again. The display will change to show RNG SET - Range set for IR sensor. UNIT TYP - Type of unit (REFRIG or NON-REFRIG) RST BCNT - Reset bottle count If the button is not pushed again the display will scroll through the three messages above for three cycles and return to run mode. 3) When display shows RST BCNT push program button once the display will show current value e.g. 00033183. 4) Once display shows current value push the program button once more to reset back to 0. The display will show BTLCT = 0 for approximately 2 seconds and then return to run mode showing 00000000 bottles. 5) To test bottle counter: REFRIG units: Push and hold Bottle Filler Button for 9.4 seconds to see bottle counter count 00000001. (This is based on filling a 20 oz. bottle). NON-REFRIG units: Push and hold Bottle Filler Button for 6.25 seconds to see bottle counter count 00000001. (This is based on filling a 20 oz. bottle) Page 7 98980C (Rev. G - 01/15)

98980C (Rev. G- 01/15) BF11 PROGRAM SETTING THE CONTROL BOARD VERIFY CONTROL BOARD SOFTWARE 1) To verify the software program of the control board the unit will need to be shut down and restarted. The chiller (if present) does not need to be shut down and restarted. 2) The units lower panel must be open to access the power cord and wall outlet. 3) Shut down the unit by unplugging the power cord from the wall outlet. 4) Restart the unit by plugging the power cord back into the wall outlet. 5) Upon start up, the bottle count display will show the software designation of BF11. 6) Reference the BF11 instructions for setting the control board. ACCESSING THE PROGRAMMING BUTTON 1) To access the program button remove the top cover of the bottlefiller. Remove the two (2) screws holding top cover to bottlefiller with a 5/32 allen wrench. Remove top cover. Do not discard mounting screws, they will be needed to reinstall the top cove after programming operations are completed. The programming button is located at the top right side of the unit on the control board. RESET THE FILTER MONITOR 1) Instructions apply to filtered units only. 2) Depress the program button for approximately 2 seconds until the display changes then release. The display will change and scroll through two messages: RST FLTR Reset Filter Monitor If the program button is not pushed again the display will scroll through the two messages above for three cycles and then default back to bottle count and be back in run mode. 3) When the display changes to RST FLTR, depress the button again. The display will change to show FLTR =. Depress the button again and the display will show FLTR =0 4) The Green LED should be illuminated indicating that the visual filter monitor has been reset. SETTING RANGE OF THE IR SENSOR 1) Depress the program button for approximately 2 seconds until the display changes then release. The display will change and scroll through two messages: If the program button is not pushed again the display will scroll through the two messages above for three cycles and then default back to bottle count and be back in run mode. 2) When the display changes to SETTINGS, depress the button again. The display will change to show RNG SET - Range set for IR sensor. UNIT TYP - Type of unit (REFRIG or NON-RFRG) FLT SIZE - Select filter capacity RST BCNT - Reset bottle count 3) When display shows RNG SET push program button once the display will show current value (can be 1 10) e.g. RNG = 3. 4) Once display shows current value push the program button to scroll through value of 1 10. Select the desired range setting. 5) Once range is selected allow approximately 4 seconds to pass and then the display will go back to bottle counter and be in run mode. 6) Test bottle filler by placing bottle or hand in front of sensor to make sure water is dispensed. SETTING UNIT TYPE 1) Depress the program button for approximately 2 seconds until the display changes then release. The display will change and scroll through two messages: If the program button is not pushed again the display will scroll through the two messages above for three cycles and then default back to bottle count and be back in run mode. Continued from below: 2) When the display changes to SETTINGS, depress the button again. The display will change to show RNG SET - Range set for IR sensor. UNIT TYP - Type of unit (REFRIG or NON-RFRG) FLT SIZE - Select filter capacity RST BCNT - Reset bottle count 3) When display shows UNIT TYPE push program button once the display will show current value. Can be REFRIG or NON-RFRG 4) Push button once to change value. Once value is selected the display will show the new value. (Can be REFRIG or NON-RFRG) REFRIG - stands for refrigerated product. In this setting the flow rate is estimated at 1.0 gallon per minute. NON-RFRG - stands for nonrefrigerated product. In this setting the flow rate is estimated at 1.5 gallons per minute. Both REFRIG and NON-RFRG simulate 1 bottle equal to 20 oz. 5) Allow approximately 4 seconds to pass and the display will return to bottle counter and be in run mode. RESETTING BOTTLE COUNT 1) Depress the program button for approximately 2 seconds until the display changes then release. The display will change and scroll through two messages: If the program button is not pushed again the display will scroll through the two messages above for three cycles and then default back to bottle count and be back in run mode. 2) When the display changes to SETTINGS, depress the button again. The display will change to show: RNG SET - Range set for IR sensor. UNIT TYP - Type of unit (REFRIG or NON-RFRG) FLT SIZE - Select filter capacity RST BCNT - Reset bottle count If the button is not pushed again the display will scroll through the four messages above for three cycles and return to run mode. 3) When display shows RST BCNT push program button once the display will show current value e.g. 00033183. 4) Once display shows current value push the program button once more to reset back to 0. The display will show BTLCT = 0 for approximately 2 seconds and then return to run mode showing 00000000 bottles. 5) Testing the bottle counter: REFRIG units: Place bottle or hand in front of sensor for 9.4 seconds to see bottle counter count 00000001, (This is based on filling a 20 oz. bottle). NON-RFRG units: Place bottle or hand in front of sensor for 6.25 seconds to see bottle counter count 00000001, (This is based on filling a 20 oz bottle). SETTING FILTER CAPACITY 1) Depress the program button for approximately 2 seconds until the display changes then release. The display will change and scroll through two messages: If the program button is not pushed again the display will scroll through the two messages above for three cycles and then default back to bottle count and be back in run mode. 2) When the display changes to SETTINGS, depress the button again. The display will change to show: RNG SET - Range set for IR sensor. UNIT TYP - Type of unit (REFRIG or NON-RFRG) FLT SIZE - Select filter capacity RST BCNT - Reset bottle count If the button is not pushed again the display will scroll through the four messages above for three cycles and return to run mode. 3) When display shows FLT SIZE push program button once. The display will show current value. Can be 3000GAL or 6000GAL. 4) Push program button again to display the desired FLT SIZE. 5) Allow approximately 4 seconds to pass and the display will return to bottle counter and be in run mode. Page 8

PART NO. 51300C 51300C_3PK 51300C_12PK 51300C_24PK 51300C_48PK 98543C 98545C 98546C 98549C 98552C 98631C 98632C 98668C 98999C 99000C 1000001907 99002C 99003C 99004C REPLACEMENT PART KITS DESCRIPTION Filter - WaterSentry Plus Filter - WaterSentry Plus (3 Pack) Filter - WaterSentry Plus (12 Pack) Filter - WaterSentry Plus (24 Pack) Filter - WaterSentry Plus (48 Pack) Kit - Electrical Package Kit - Solenoid Valve Replacement Kit - Aerator Replacement Kit - Hardware & Waterway Parts Kit - Retro Filter Mounting Kit - Electrical Package 220V Kit - Solenoid Valve Replacement 220V Kit - Filter Mounting Cover Kit - Drain Pad Kit - Button Assembly Kit - Top Cover Replacement Kit - Gasket VR BF Tower/Basin Kit - Reset Switch Kit - Micro Switch WATERSENTRY FILTER PARTS LIST (See Fig. 7) LISTA DE PIEZAS DEL FILTRO (Vea la Fig. 7) LISTE DES PIÈCES DU FILTRE (Voir Fig. 7) ITEM NO. PART NO. DESCRIPTION DESCRIPCIÓN DESCRIPTION 1 2 3 51299C 98926C 51469C Filter Assy-1500 Gal. Kit-Filter Head Fitting Includes John Guest Fitting & 3/8 Elbow Fitting Assy-Filter & Bracket includes Fltr Head/Mtg Bkt/ John Guest Ftgs/Screws Ensamblado del Filtro-1500 Galón Montaje Cabeza Kit Filtro-Incluye John Guest Montaje y 3/8 Codo Conjunto del Filtro y Soporte, Incluye Filtro Soporte/John Guest Guarniciones/ Tornillos de Montaje de Cabeza Ens. filtre-1500 Gallon Raccord Tête de Filtre Kit-InclutJohn Guest Montage et 3/8 Raccord en Coude Assemblêe-Filtre et Support Inclut Filtre/Montage Support/John Guest/ Vis à Têtê 3 2 2 1 WATER FILTER EXPLODED VIEW Fig. 7 REPAIR SERVICE INFORMATION TOLL FREE NUMBER 1.800.260.6640 NÚMERO GRATIS DE SERVICIO 1.800.260.6640 INFORMATIONS POUR LE SERVICE PAR NUMERO SANS FRAIS 1.800.260.6640 FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.834.4816 PARA PIEZAS, CONTACTE A SU DISTRIBUIDOR LOCAL O LLAME AL 1.800.834.4816 POUR OBTENIR DES PIÈCES, CONTACTEZ VOTRE DISTRIBUTEUR LOCAL OU COMPOSEZ LE 1.800.834.4816 ELKAY MANUFACTURING COMPANY 2222 CAMDEN COURT OAK BROOK, IL 60523 630.574.8484 PRINTED IN U.S.A. IMPRESO EN LOS E.E.U.U. IMPRIMÉ AUX É.-U. Page 9 98980C (Rev. G - 01/15)