Refrigerated Compressed Air Dryer

Similar documents
Instruction Manual. Refrigerated Air Dryer

Operation regulations must be strictly obeyed.

Split Air Conditioner

- 1 - Updated on 18 March, 2010

TABLE OF CONTENTS FOR YOUR SAFETY

NEWGATE TECHNOLOGIES, INC.

NON-CYCLING REFRIGERATED AIR/GAS DRYERS QPNC 75 to QPNC 250 OPERATOR S MANUAL

- 1 - Updated on 18 March, 2010

HORIZONTAL MULTISTAGE CENTRIFUGAL PUMP

EBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

COMPANY INTRODUCTION

OIL COOLER INSTRUCTION HANDBOOK

Refrigeration air dryer

High Inlet Temperature Air Dryer. Desiccant Air Dryer. Membrane Air Dryer After-Clooler. Air Filter. Oil-Water Separator Automatic Drain Value

Energy Impacts of Compressed Air

Landfill & Digester Gas Dryers. Features and Benefits

Contour TM Screw Compressors

Owner s Manual Refrigerated Compressed Air Dryer Model F-50

.2 Section Waste Management and Disposal.

Owners Manual Refrigerated Air Dryer MHT SERIES

WINDOW TYPE ROOM AIR CONDITIONER OPERATION AND INSTALLATION MANUAL

REFRIGERANT ON-VEHICLE INSPECTION AC 14

TROUBLESHOOTING GENERAL TROUBLESHOOTING PROBLEM PROBABLE CAUSE CORRECTIVE ACTION

The breaker trips at once when it is set to ON. The breaker trips in few minutes when it is set to ON.

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features.

Owners Manual UA75 TO UA1200 SERIES Refrigerated Air Dryer

Trouble Shooting Guide PWA, 3-phase (D10571)

120D, 150D, 190D, 240D, 370B. How to Order 220V 240V 400V 440V. Note 1) Select one applicable voltage. Voltage. Voltage. Symbol. Model 370B 220V 240V

The Highest Quality Compressed air treatment Refrigerant dryers CFM 0.33 to 91.1 M/min

Double Door Over 70. Service Manual. Models: F NMTZH 821 F T F NMTZH 822 F T

EBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

HNC-120BE-L/R-B HNC-150BE-L/R-B HNC-180BE-L/R-B HNC-210BE-L/R-B COUNTER SHOWCASE MODEL SERVICE MANUAL HOSHIZAKI

RHP & FHP Series. High Pressure Air Treatment Global Air Treatment

CKD refrigerating type dryer

Installation/Instruction Manual

Electrical Problems. Fuse(s) blow or circuit breaker trips. Does the unit use circuit breakers or fuses? Replace with correct fuse(s)

Chapter 9: The basics of air preparation

40KMC KMQ

Dehumidifier. Model: GDN20AX-K4EBA1A GDN20AX-K4EBA1B

Service Manual For electronic dual temperature zone wine cellar Includes DWC282 / 283

INSTRUCTION AND MAINTENANCE MANUAL

Owner s Manual Refrigerated Compressed Air Dryers Model F-100

WILKERSON MODELS DE3, DE4 AND DE5 COMPACT HEATLESS AIR DRYERS

Full Range Systems. Mokon Troubleshooting Guide Model 311. Process/Water Loop. Problem Possible Cause Corrective Measure. Process pump will not start

Tel: Fax: Website:

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

MDX. Non-Cycling Refrigerated Compressed Air Dryers with zero-loss Intellidrain Drain Trap. Operation & Maintenance Manual MDX MODELS 18 THRU 250

Treatment. Compressed Air. Equipment CONTENTS

INSTRUCTION AND MAINTENANCE MANUAL DRYERS A 11 - A 12 - A 13 - A 14 (R410A)

Owner s Manual Refrigerated Compressed Air Dryers Models F-200, 250, 300 & F350

HTD. High Temperature Non-Cycling Refrigerated Compressed Air Dryers. Operation & Maintenance Manual. MODELS HTD 21 thru HTD 100

π H-6621 INDUSTRIAL DEHUMIDIFIER WARNINGS SPECIFICATIONS uline.com WATER REMOVAL ELECTRICAL REQUIREMENTS BUILT-IN ELECTRICAL SAFETY

INSTRUCTION AND MAINTENANCE MANUAL DRYERS A5 - A6 - A7 - A7,5 - A8 - A9 - A10

PORTABLE AIR-CONDITIONER MODEL: EPAC-A4010D(WH) Owner s Manual Please read this manual carefully before operating your set.

ZLA Series Double-stages Vacuum Transformer Oil Purifier Transformer Oil Purification

EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

PETECO VIETNAM EQUIPMENT JOIN STOCK COMPANY TYA VACUUM LUBRICATING/HYDRAULIC OIL PURIFIER

FUTURE AIR SOLUTIONS OIL FREE SCROLL COMPRESSORS

Trouble Shooting Guide RAA, 1-phase (D3627)

Digital Refrigerant System Analyzer. MAXMIN Psi kpa Bar MPa C F R TIME P T UNITS

NO FROST MODEL: RD-44WC*

Auto Service Test Review. For the Most Effective Personal Review, Match the Following Questions to the On Line Study Guide Multimedia

Trouble Shooting Guide PAA, 1-phase (D3731)

EBAC MODEL K100 DEHUMIDIFIER OWNER S MANUAL

DTW Works Master Specification Version 2006 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5

Parts introduction FRONT BACK

REFRIGERATED AIR DRYERS

Refrigerated Air Dryers. Catalogue

OPERATING & MAINTENANCE MANUAL HORIZONTAL WATER SOURCE HEAT PUMP. World class comfort.

SECTION AIR COMPRESSORS AND ACCESSORIES

HMT-D30-A HMT-D45E-A HMT-D70E-A. Model Numbers: HMT-D30-A HMT-D45E-A HMT-D70E-A. Portable Dehumidifier Operating Instructions V.

INVERTER ONE-TWO/ONE-THREE/ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER

Technical Specification

Trouble Shooting Guide FAA, 3-phase (D3631)

Service Step by Step Trouble-Shooting Check-List

Residential Gas Hybrid Water Heater

WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS

Owner s Manual. Middle Static Pressure Duct Type MEU-18MPH2 MEU-24MPH2 MEU-36MPL2 MEU-48MPL2 MIDDLE STATIC PRESSURE DUCT TYPE AIR CONDITIONER

SCFM REFRIGERATED COMPRESSED AIR DRYERS. CRN Series

RNC Series SCFM Global Air Treatment

NON-CYCLING REFRIGERATED AIR DRYERS. RNC Series

Air Conditioning Operation and Troubleshooting Matt Dunham

INSTRUCTION MANUAL Wall mounted Cooker hood Nebel INOX 90

PUGMILL/MIXER. Instruction Manual NVS-07

Hot Water Circulator Pump LRP

LABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS

Owner s Manual INVERTER ONE-TWO/ONE-THREE /ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER

INDEX. Air flow capacity SCFM (m 3 /h [ANR]) Model Outlet air pressure dew point Note) 37 F (2.8 C) 45 F (7.2 C) 50 F (10 C)

EURO APPLIANCES BY EUROSTYLE GROUP

WALLACE MAXIPUMP 3000, 5000, 6000 and HYDROJET 30P, 30C, 140 AND HJ400 INSTALLATION AND MAINTENANCE INSTRUCTIONS

Rust, corrosion and leakages threaten even the best network. Only Quality Air Solutions. in optimal shape. air distribution

RNC Series SCFM Global Air Treatment

MODEL MW200 MODEL MW600 AIR DRYER

WineZone Ceiling Mount Ductless Split 15

Owner s Manual INVERTER ONE-TWO/ONE-THREE /ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER

Operation Manual R205BV, R209BV

SECTION air supply system + WARNING: + NOTE: GENERAL DESCRIPTION COMPRESSED AIR RESERVOIRS / 1.

Technical specifications GX

AIR COOLED PACKAGED CHILLER

Port-A-Cool unit. Pneumatic Owner s Manual. series manufactured by port-a-cool, llc FOR PNEUMATIC MODELS PAC2K36AD, PAC2K24AD, PAC2K16AD

Transcription:

Manual Instruction for Refrigerated Compressed Air Dryer Warning: Place the dryer machine horizontal. Never upside down Dino-power Industry & Trade Co., Ltd www.aircompressorschina.com Dino-power 1

PREPARED Thank you for using DINO-POWER air dryer products! Before using the equipments, please read this book carefully and make sure you are strictly following the requirements below. 1. The pressure of compressed air dryer should not exceed the maximum pressure allowed. (labeled Nameplate). 2. Before repairing or removal, make sure the system is without pressure. 3. Power must be consistent with the nameplate labeled on the machine. 4. While repairing, be sure of cutting off the power to ensure security. 5. While repairing, you should comply with the public safety codes of producer. If you do not follow this method of operation and general maintenance, we are not responsible for the danger. 1 Product Overview Our Dino-power brand refrigerated compressed air dryers is a kind of compressed air purification and drying equipment. Our dryer is improved product based on the model of advanced international level. Under the action of the machine, the pressure dew point of compressed air can reach 2-10 (0.7 MPa) equivalent to usual dew point about -23-17. In addition to, the rate of dewater up to 93 percent, containing oil no more than 5 PPM. It can filter all the impurities which are bigger than 0.01 μm, with 99.999 percent of de-oiling (see compressed air filters manual) if you equip with our high-precision filter. Then there are water-free, oil-free, dust-free high purified compressed air to meet the demands of aerodynamic control drive, precision instruments, spray painting and plastic, food, medicine, electronic components, metallurgical ships, diver breathing and so on. We adopt advanced refrigeration technology, and lower the temperature forcibly, so that the large number of water vapor, fuel-air can turn into condensation droplets, which will be drained. Dino-power dryers equip with international famous brands refrigerant compressor, and other high-quality imported components for key components. Our products play a smooth and reliable performance, with low noise, but long life. What s more, the products have an average continuing working time of more than 10,000 hours. 2 Usage requirements 1. Choose proper rearward compressed air cooler, tank, filter, cold and dryer machine. The rearward compressed air cooler and tank are necessary, which must be to be installed in between the air compressors. Grade C filter should be equipped, while others can be decided by operator. 2. Using conditions: Ambient temperature: 42 (water-cooled type are unrestricted) Inlet temperature: general products 45 ; high temperature type 80 Inlet pressure: 0.2 MPa ~ 1.0MPa (Over 1.0 MPa can be ordered also) Cooled water amount: calculate by 1 Nm3/min to 0.18 t / H Cooled water temperature: inlet temperature 35 Cooled water pressure: 0.2 ~ 0.4 MPa Installation environment: a well-ventilated and dust-free place Dino-power 2

3 install the dryer 1. Horizontal place the machine. Never upside down, otherwise the compressor will be broken. 2. From the outlet of air compressor to the inlet of the dryer machine, the pipe should be kept rust-free, and do not make the water pipe bend. 3. Keep at least one meter away from wall / surroundings for better operation, daily maintenance and repair. Be sure of air-cooled type machines are ventilation. About water-cooled type machines, inlet pressure shall be at least 0.2 MPa higher than outlet pressure; the flow must match up to the diameter of pipe line; inlet water temperature cannot exceed 35 filtered at the entrance). Dino-power 3 without impurities (can be 4. Dryer machine is refrigeration equipment, while loading, unloading; transportation and installation should avoid strong shock and with less tilt. And Never Upside Down. 5. At the inlet and outlet pipeline of the dryer should install repair valve and bypass valve. See the picture of illustration. 6. If it s installed for the piston compressor. the air tank can be installed in the front so as to prevent vibration and pulse. 7. For Water-Cooled type machines, cooling water pipes should be a separate installed. It s better not use one pipe both for cooling water and other cooling equipment. 8. While installation of automatic drainage, be careful of breaking the small screw. 9. Electrical installation A. Private wire--make a specific mains switch, do not share with other electrical equipment. B. Voltage fluctuations within ± 5%. C. Besides electrical power set a series devices, such as electromagnetic starter, air switch (or valve switch), fuse and so on. D. Correct grounding. 4 Analysis of the machine problem and the resolution Faults caused by both internal and external generally are six factors, as following: 1. Too much pressure drop Piping system error Air handling capacity is more than ratings Water in the Evaporator freeze Pipe valve is not fully opened Diameter is too small Pipe-Line is too long, elbow, too many joints Two or more air compressors parallel operation with non-performing district Pipeline filter blocked Open the Valves fully Increase the pipe diameter Pipeline system re-design Pipeline system re-design Filter cleaning or replacement Pipeline leakage Elbow joint inspection and Rated over air compressor to reduce traffic pressure on the natural Temperature switch or pressure switch broken. Expansion valve, air bypass valve failure Air handling capacity is too small change it 1, replace of the large capacity air compressor 2, to reduce air displacement, inspection lines, switching correction, check whether the pipeline obstruction, correction switch Increase the air volume

2. Dewater not effective Bypass valve does not close totally Close bypass valve Piping system Air Not pass the air dryer Open all the dryer inlet valve abnormalities No tank, or the tank equipped Re-Storage devices, as required after the dryer machine Dryer-not horizontal Set it horizontally Auto-drainage tilt Set it horizontally Drainage pipes above the automatic Redesign the drain devices drainage The air displacement is too much pressure dropped too much Pneumatic source system re-equipped Abnormal drainage Drainage is not good, or Cleaning or replacement system electromagnetic valve failure Drainage s front valve is not open Make sure the valve position to be full open Dew point and humidity is too low or too high Adjust the pressure switch, water-flow switches, expansion valve, air bypass Evaporative cooling valve temperature anomalies instructions Ambient temperature and the inlet temperature is too low It does not matter, can continue to use the dryer Inlet temperature too high Additional attach rear cooler The surrounding environment Choose a more appropriate location or polluted, air ventilation bad improve ventilation Refrigerant coolant leakage, low Mending leakage, and irrigation frozen efficiency refrigerant 3. Do not work properly Whether the normal power supply Fuse or a switch melting trip Make sure the power is not in short-circuit, grounding phenomenon, no fuse switch and check whether the damage Disconnection Identify break, to overhaul Abnormal voltage Please follow the instructions nameplate on the rated voltage of 5 percent to allow Switching bad Contacts with non-performing Over-current relay bad Have power but can High/low pressure switch bad not start Bad electrical on-off switch Bad capacitors Bad Temperature switch, bad delivery switch, oil compression Compressor bad All normal switches No return back after Find out the reasons for replacement trip, and are good, but could over-loading limit. then reset not be activated Compressor bad Wire-off Find it, and make it tighten. Dino-power 4

4. Proplems after started Abnormal voltage electrical short circuit quickly, and smells burned. Identify the reason of abnormal voltage, and re-configuration, Could not be activated even though the over Pressure switch or temperature switch bad, fans stop Switch replacement loaded high-pressure Fan bad switch returned. Overload trip Check Relays Condenser fouling too much Cleaning the condenser Over-current trip relay Relays bad start Bad capacitors Pressure switch or temperature switch bad, fans stop. Adverse hydraulic switch Row start Each time you start to be separated from more than three minutes Compressor overloading Dryer overload, reduce air handling capacity Drying the entrance to the ambient Additional coolers or improve temperature is too high or the temperature ventilation Relays set current value is too low Current value adjustments Relays connection is bad Clean-up or replacement Power is owed Fuse or off the power switch connection is bad Contacts with non-performing Clean-up or replacement contact bad No cooling water cycle Check the cooling water 5. Work fine, but not so effective temperature refrigerant evaporation indicates low Refrigerant instructions excessive evaporation temperature of too Thermometer different evaporation Heat expansion valve or bypass valve failure Refrigerant leakage Refrigerant obstruction Temperature or pressure switch switches set too low fan running continuously Entrance temperature is too high (over 45 more) The ambient temperature too high Heat expansion valve or bypass valve failure Condenser obstruction, poor ventilation Cooling water temperature too high, or bad cycle Dino-power 5 Mending leakage reperfusion refrigerant charge Replacing the desiccant, re-vacuum, Filling refrigerant Set temperature adjustment switch or pressure control switch Attach with extra cooler, or replace to the larger capacity dryer Additional ventilation equipment Cleansing, improving the ventilation equipment Improve the cooling water

Overload operation Air-handling capacity, but low pressure Refrigerant compressor into the exhaust valve-wear Entrance temperature is too high (over 45 more) Air handling, but low pressure Refrigerant leakage Parallel to install dryer Additional cooler Parallel to install dryer Filling mending leakage reperfusion 6. Automatic bad drainage system The use of pressure in the 1.5 Kg / cm below Automatic drainage for the normal operating pressure in the 2-10 Kg / cm Festival part of obstruction Cleaning Drainage valve damage or full or open valves Drainage is tilted or damaged Correction fixed or replacement Some filters for blocking drainage Cleaning The use of high pressure According to the automatic use of drainage-rated pressure Blocked drains Cleaning Evaporator, rusty or Pipeline dirt obstruction Life over, replacement 5 Notice and warning 1. Check the third step whether meet the requirement. 2. Check the power whether the voltage/phase is correct. The electrical wiring whether correct. 3. Make sure Air-cooled dryer are ventilation. And Water-cooled type machine whether smooth enough. And pay attention to water pressure, water quality, water temperature. 4. Make sure the front and back filter are installed correctly. 5. Bypass and repair valve are closed or not. Repair valve at outlet is open or not. 6. Automatic drainage-ball valve is open or not. 7. Machine with pressure gauge of Freon, check the status of static observation table is normal or not. Usually, the two table static instructions of the machine with high and low pressure gauge should with similar status. 8. Models have a relay, make sure that it has set up start-up delay time (generally, delay about 2-3 minutes). 9. Entrapped air whether cleared or not. After checking all above steps, you can start the machine; pay more attention to whether there is noise from the compressor, compressor running smoothly or not. What s more, inspecting high-pressure refrigerant gauge rise or not, low-pressure refrigerant whether decrease (If no tables, touch the refrigerant compressor to feel the temperature of vent-pipe is higher or lower than it of suction pipe). For air-cooled type, Make sure fans of the air-cooled machine can be started and stopped automatically. Condensing fan: Fan worked (Low pressure: 0.44 MPa or high-pressure 1.6 MPa). Fan stopped (Low pressure: 0.4 MPa high-pressure or 1.4 MPa) For water-cooled type, Low-pressure refrigerant gauge should show a certain value between 0.4 ~ 0.45 MPa; and the high-pressure one shall be a data between 1.4 ~ 1.6 MPa. In this case, it works normally. Then, switch on air compressors. After the tank pressure reach 0.7 MPa, gradually open Dino-power 6

the inlet repair-valve, and let the compressed air enter into the dryer machine slowly. Do not open the valve fully and suddenly, in order to prevent the evaporators and other components damaged by shock wave. In addition, frequently switch on / off refrigerant compressor is prohibited, otherwise compressor motor will be broken. 6 Dryer installation drawing 1, heat exchangers 2, evaporator 3, air and water separator 4, drainage anti-block filter 5, automatic drainage valve 6, refrigerant compressors 7, suction filter 8, carburetor 9, sub-line 10, the first air-liquid mixture 11, thermal expansion valve 12, endoscopic 13, dry filter 14, reservoir 15, hot air bypass valve 16, water control valve 17, water filter 18, the condenser (air-cooled) 19, the condenser (water) 20, pre-cooling (water) 21, pre-cooling (air-cooled) Thanks for chosing Dino-power compressed air dryer machine. If you have any other question, or problem with our product, please kindly contact your local distributor, or contact us freely thanks Dino-power 7