"ETI-Z, GART-ZE/ZEI" Centrifugal Chillers using Low-GWP Refrigerants for Full Capacity Range

Similar documents
ETI-Z Series Centrifugal Chiller Applied Low GWP Refrigerant to Contribute to the Prevention of Global Warming

Development of centrifugal chiller and heat pump using low GWP refrigerant

Development of centrifugal chiller and heat pump using low GWP refrigerant

Current status of Japan s legislation on F-gases and RACHP using Low-GWP Refrigerants

High-efficiency Turbo Chiller (NART Series)

Update on Next Generation Low GWP Refrigerants for Chillers Products. Steve Kujak Director, Next Generation Refrigerant Research

CHAPTER 1 INTRODUCTION

Daikin s Policy. and Comprehensive Actions on the Environmental Impact of

Transitioning to Alternatives and Challenges in Japan

Challenges and responses in refrigerant conversion

Transitioning to Alternatives and Challenges in Japan

Featuring Ozone-safe HFC134a. Hitachi Centrifugal Chillers NEW. GXG-S Series GSG-S Series. Debut

Current use of HFCs and HCFCs. Trends, alternatives and climate impact. YEREVAN, Armenia, May 18-19, International Institute of Refrigeration

Member Briefing JAPAN

FACT SHEET 9 Large Air-Conditioning (air-to-air)

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

FACT SHEET 9 Large Air-Conditioning (air-to-air)

Main Anthropogenic Sources of Greenhouse Gases Refrigerants

Refrigerants & Cooling in renovation buildings

NATURAL REFRIGERANTS FOR HEAT PUMPS AND AIR-CONDITIONING SYSTEMS. Bernard Thonon Greth

Chillers and Refrigerants. Purpose of Today s Presentation. Agenda. GLHN Architects & Engineers, Inc. APPA Institute Session 322 EU

Policies and Measures for HCFCs in Japan

Featuring Ozone-safe HFC134a. Hitachi Centrifugal Chillers. NEW GXG-S Series GSG-S Series Debut

A Comparison Between Refrigerants Used In Air Conditioning

Industry co-operation on Natural Refrigerant technology development Kenji Matsuda

Centrifugal Chiller. GFG-S/SIT Series GXG-S/SIT Series GSG-S/SIT Series

EVALUATION OF REFRIGERANT R290 AS A REPLACEMENT TO R22

Experimental Study on Compact Heat Pump System for Clothes Drying Using CO 2 as a Refrigerant. Abstract

Brazed Plate Heat Exchanger for CO Applications

The Current Path of Refrigerants

Evaluation and Development of Air-conditioners using Low GWP Refrigerant

Actions to Control Emission of HFCs in Japan

Midea VFD Centrifugal Chiller Technology

Making equipment decisions

CHAPTER 1 INTRODUCTION

Q. Which hydrocarbons can be used as a refrigerant? The following hydrocarbons can be used as a refrigerant in cooling & heating applications:

HFCs or the Old Refrigerants - what is the best Choice?

Flammability and New Refrigerant Options

Large AC units using a variety of low-gwp options

Technical Development Program

HFO-1234yf Performance in a Beverage Cooler

A Primer on HFOs. Hydrofluoro-olefins Low-GWP Refrigerants. Brett Van Horn, PhD Arkema Inc.

WATE R -C OOLE D WATE R C H ILLE R S

η second law = Second law efficiency

Low GWP Refrigerants for Air Conditioning Applications

Hitachi Centrifugal Chillers

Oct. Newly Developed Refrigerants for Refrigeration, meeting Global Warming Regulations. Hitomi ARIMOTO / Product R&D Department, Chemicals Division

Alternatives in the AC & Chiller Sectors. Sukumar Devotta and Lambert Kuijpers OORG Refrigeration

RS-70 is suitable as a direct replacement for R-22 in low, medium and high temperatures in a great number of applications:

APS Chiller Seminar. Don Brandt, CEM-AEE, BEAP-ASHRAE ASHRAE and IEEE Life Member 3/16/2017

High Efficiency Technologies for Small and Medium-Sized Air Conditioning Equipment Using R410A. Hitachi Appliances, Inc.

The Development of Heat Pump Water Heaters Using CO 2 Refrigerant

Study of R161 Refrigerant for Residential Airconditioning

CO 2. ECO Water Heaters. Energy efficient and environmentally friendly water and space heating. SANYO Air Conditioners. The natural choice.

Low GWP alternative refrigerants to R404A

ANALYSIS OF LGWP ALTERNATIVES FOR SMALL REFRIGERATION (PLUGIN) APPLICATIONS

Development of R744 Two Stage Compressor for Commercial Heat Pump Water Heater

DEVELOPMENT AND EVALUATION OF HIGH PERFORMANCE, LOW GWP REFRIGERANTS FOR STATIONARY AC AND REFRIGERATION

Chillers for High Ambient Conditions: What Technologies and Fluids?

New F-Gas Regulation (2014): Guidance for Food and Drink Manufacturers. REI Guide 4a. The 2014 EU F-Gas Regulation

Volume 3, Issue 4 (2015) ISSN International Journal of Advance Research and Innovation

GEA Blu chillers. GEA BluAstrum, GEA BluGenium, GEA BluAir: A new generation of compact ammonia chillers

Comparative assessment for drop in replacement of R134a in domestic refrigerator.

Be sustainable while protecting your business

Due to its low temperature glide about 1.5 approx. (75% less than R-407C and R-427A), it is suitable for a wide range of applications.

PACKAGED REFRIGERATION EQUIPMENT

New Case studies on Low GWP alternative refrigerants for HFCs. ABHIJEET KUDVA

March 2014 AHRI Presents Research Findings at Low-GWP AREP Conference

Kawasaki centrifugal chiller using water as a refrigerant. Sep 26 th 2017 Kawasaki Heavy Industries, Ltd. Machinery Division Hayato Sakamoto

The analysis proceeded by adopting the ASHRAE guideline for conventional HVAC chiller applications. This guideline is summarized in Table II.

System Drop-in Tests of R-134a Alternative Refrigerants ARM-42a and R-1234ze(E) in an Air- Cooled Screw Chiller and a Water-cooled Centrifugal Chiller

Japanese market and issue of Heat Pump Kenji Matsuda

Chapter 10. Refrigeration and Heat Pump Systems

R-407A R-448A R-449A

Assessment of Alternatives to Refrigerant R134a in Automotive Air Conditioning System

Chapter 2. Alternatives to HCFCs and their Characteristics

2017 Climate & Refrigerants Outlook. Stephen Yurek President & CEO

Industrial Heat Pumps and Their Application Examples in Japan

Global Solutions for Ammonia Industrial Refrigeration

Evaluation and Optimization of System Performance using HFO-mix Refrigerants for VRF and Mini-split Air-Conditioner

Overview of the Refrigeration Safety Ordinance

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

Effectively Managing the Transition to Lower GWP Refrigerants

Requirements for the Collection, Transportation, Storage and Treatment of Cooling and Freezing Appliances containing Hydrocarbons (HC)

Stay in business: STOP installing R-404A / R-507A! R-404A R-507A

International Journal of Research in Engineering and Innovation Vol-1, Issue-5 (2017), 68-72

Use of fourth generation ecofriendly refrigerants in two and three cascade refrigeration systems for reducing global warming and ozone depletion

Energy Performance of Low Charge NH3 Systems in Practice. Stefan S. Jensen

R-404A Alternative with Low Compressor Discharge Temperature

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

NATIONAL HALON MANAGEMENT STRATEGY

A2L Refrigerants. Objectives 14/09/2017

FACT SHEET 6 Transport Refrigeration

Ammonia. Background on ammonia as a refrigerant

Eco Compact Series GAS HEAT PUMP

Overview of Alternatives and Climate Impact Scenarios Report of Decision XXV/5 Montreal Protocol

Seminar 34 Refrigerants Today, Tomorrow, and Beyond

Campbell Soup Company Extends Use of CO2 Systems Into Their Operations

Scroll Chillers Transition from HCFC-22 to HFCs

CH2351 Chemical Engineering Thermodynamics II Unit V Refrigeration. Dr. M. Subramanian

Transcription:

3 "ETI-Z, GART-ZE/ZEI" Centrifugal Chillers using Low-GWP Refrigerants for Full Capacity Range YOSHIE TOGANO *1 JUN MIYAMOTO *1 YOSHIE KANKI *1 KAZUMI SHIMIZU *1 TAKAAKI MIURA *2 YASUSHI HASEGAWA *3 In October 2016, the Kigali Amendment to the Montreal Protocol was adopted. It states that it is obligatory to phase down the production and consumption of hydrofluorocarbons (HFCs), which has set an important global trend in refrigerants. In developed countries, the target is an 85% reduction by 2036 from the respective reference years (2011-2013). As further enforcement of tougher regulations for HFC reduction can be expected, there is an urgent need to start using low global warming potential (GWP) refrigerants. From the viewpoint of product life cycle, it will become increasingly unlikely for centrifugal chillers using HFC refrigerants to be introduced. Under such circumstances, Mitsubishi Heavy Industries Thermal Systems, Ltd. launched the ETI-Z series in September 2015 using HFO-1233zd(E) with a GWP of 1, and the GART-ZE/ZEI series in April 2017 using HFO-1234ze(E) with a GWP of <1. Thus, low GWP refrigerants are used in all our centrifugal chiller models with cooling capacities ranging from 150 refrigeration tons (RT) to 5000 RT. 1. Introduction The 28th Meeting of the Parties to the Montreal Protocol (MOP28) was held in October 2016, and the Kigali Amendment to the Protocol was adopted to prescribe the obligatory gradual reduction of HFC production and consumption, etc., thus clearly setting the course towards terminating the use of HFCs. In the fields of heating, ventilation and air conditioning (HVAC) and refrigeration, although measures to mitigate global warming such as the F-gas Regulation in Europe and the Fluorocarbon Emission Control Law in Japan have been enacted, even more effort will be required. Centrifugal chillers are used as the cold source in district heating and cooling systems, HVAC systems in buildings and plants, and process cooling systems in chemical and food factories. With the use of centrifugal compressors, centrifugal chillers produce chilled water with cooling capacities ranging from 150 RT to 5000 RT. Their global warming impact factors include indirect CO 2 emissions due to electricity consumption during operation, and direct greenhouse gas emissions to the atmosphere in unexpected incidents such as refrigerant leakage. We have always taken on the challenge to reduce CO 2 emissions from chillers, by dedicating itself toward the realization of optimal control and improved efficiency of compressors and heat exchangers for reduced power consumption during operation, as well as enhancing maintenance services such as regular leak inspections to minimize the release of refrigerant to the air. However, it has been a concern that the impact of only a very small leak of HFC refrigerant would be significant because of its high GWP. In response to the market s fundamental need to terminate the use of substances that can contribute to global warming, we have used low GWP refrigerants in all centrifugal chiller series models throughout the capacity range, which is a first among our domestic competitors. None of the models of these series are subject to the Fluorocarbon Emission Control Law. This report introduces the features and specifications of these centrifugal chiller series using low GWP refrigerants. *1 Chiller & Heat Pump Engineering Department, Mitsubishi Heavy Industries Thermal Systems, Ltd. *2 Manager, Chiller & Heat Pump Engineering Department, Mitsubishi Heavy Industries Thermal Systems, Ltd. *3 Chief Staff Manager, Chiller & Heat Pump Engineering Department, Mitsubishi Heavy Industries Thermal Systems, Ltd.

4 2. Selection of low GWP refrigerants The following issues were considered when selecting suitable low GWP refrigerants for centrifugal chillers. (1) Environmental soundness The refrigerant to be selected should not be destructive to the ozone layer and should have a GWP of 150 or lower. (2) Physical properties It is important to have a refrigeration cycle efficiency as good as that of HFC-134a and not to require extremely high design pressure in any chiller components. Refrigerant physical properties determine energy consumption, CO 2 emissions, and working pressure ranges. High working pressure increases the wall thickness of chiller components to produce sufficient strength, consequently increasing the cost as well. (3) Availability There should be applications other than centrifugal chiller refrigerants, to ensure a certain level of production. When compared with multi-split building air conditioners, centrifugal chillers require a smaller amount of refrigerant per unit of cooling capacity and are manufactured in smaller quantities. The amount of refrigerant used is smaller than other types of air conditioning systems (such as multi-split building air conditioners, and automobile air conditioners). Therefore, from the viewpoint of constant availability and prices, it is important that the refrigerant is also used as a foaming agent or in other air conditioning systems as well. (4) Safety The refrigerant to be selected should be able to be handled as non-flammable and have low toxicity as per the High Pressure Gas Safety Act of Japan. Table 1 Refrigerant comparison Conventional refrigerant New refrigerant (low GWP) HFC-245fa HFC-134a HFC-32 HFO-1234yf HFO-1234ze(E) HFO-1233zd(E) Global warming potential (GWP) *1 858 1300 677 <1 <1 1 Ozone depletion potential (ODP) 0 0 0 0 0 0 Classification (High Pressure Gas Safety Act, NA *2 Inert gas Inert gas *3 Inert gas *3 Inert gas *3 *2 Refrigeration Safety Regulation) Atmospheric lifetime 7.7 years 13.4 years 5.2 years 10.5 days 16.4 days 26 days Long-term exposure toxicity [ppm] (allowable concentration) 300 1000 1000 500 800 800 Boiling point [ C] (at atmospheric pressure) 15.1-26.1-51.7-29.4-19.0 18.3 Saturation pressure (at 6 C) [kpag] *4-32.1 260.7 879.8 23.9 167.3-39.1 Saturation pressure (at 38 C) [kpag] *4 133.1 861.9 2258 866.4 624.3 100.8 Specific volume of saturated gas [m 3 /kg] *4 (at 6 C) 0.241 0.056 0.037 0.047 0.069 0.277 Specific volume of saturated gas [m 3 /kg] *4 (at 38 C) 0.075 0.021 0.014 0.018 0.026 0.091 Theoretical COP *5 6.86 6.58 6.38 6.31 6.56 6.93 Availability Medium High High Low Low Low Overall rating *6 *1 Intergovernmental Panel on Climate Change (IPCC) Fifth Assessment Report *2 The High Pressure Safety Act is not applicable to R-245fa and R-1233zd(E), when used for chillers under the specified conditions. *3 Designated inert gas It is necessary to install a mechanical ventilation system (interlocking mechanism between the chiller and the ventilator) with a prescribed ventilation capacity, as well as a refrigerant leak detection and alarm system. *4 NIST Reference Fluid Thermodynamic and Transport Properties Database (REFPROP) Version 9.1 *5 Two-stage compression/two-stage expansion sub-cooler cycle. Refrigeration cycle efficiency at evaporation temperature of 6 C, condensation temperature of 38 C, and adiabatic efficiency of 90%. *6 : Low GWP and high theoretical COP, : Low GWP, but theoretical COP not as good as HFO-1234ze(E) or HFO-1233zd(E), : High GWP In selecting low GWP refrigerants for centrifugal chillers, we have examined those listed in Table 1. HFO-1234yf and HFO-1234ze(E) exhibit physical properties that are relatively similar to those of HFC-134a, and are classified as designated inert gases according to the High Pressure Gas Safety Act. On the other hand, the physical properties of HFO-1233zd(E) are close to HFC-245fa rather than HCF-134a. When used in air conditioning systems, it yields only a refrigerant pressure

Mitsubishi Heavy Industries Technical Review Vol. 54 No. 2 (June 2017) 5 of less than 0.2 MPaG, and therefore the above Act is not applicable. Because the GWPs of these substances are all below 1, none of them are bound by the Fluorocarbon Emission Control Law. Based on the detailed examination regarding (1) to (4) and other considerations such as risk assessment results, we decided to use HFO-1233zd(E) for chillers with small capacities and HFO-1234ze(E) for chillers with large capacities, respectively. 3. Series line-up Our centrifugal chillers with low GWP refrigerants are commercially available in the ETI-Z series (small capacity range) and the GART-ZE/ZEI series (large capacity range). The combined capacity of refrigeration in these series ranges from 150 RT to 5000 RT. Figure 1 shows the capacity range of each series, together with that of the earlier series using the conventional HFC-134a refrigerant. Figure 1 (1) ETI-Z series Using HFO-1233zd(E) with a GWP of 1, this series covers the capacity range of 150 RT to 350 RT by single model units with a single compressor, and can also achieve a maximum of 700 RT using parallel model units with two compressors. The series is equipped with the 400 V class inverter as standard. The exterior view is shown in Figure 2. Figure 2 (2) Product line-up of our centrifugal chillers Exterior view of the ETI-Z series GART-ZE/ZEI series The refrigerant in this series is HFO-1234ze(E) with a GWP of less than 1. This series can offer a capacity range of 300 RT to 2500 RT using single model units with a single compressor, and a maximum of 5000 RT using parallel model units with two compressors.

With constant speed models (GART-ZE) as standard, the series also includes variable speed models (GART-ZEI). The exterior view is shown in Figure 3. 6 Figure 3 The exterior view of GART-ZE/ZEI series 4. Applied technologies The specific volume of gaseous HFO-1233zd(E) in the ETI-Z series is about 5 times as large as that of HFC-134a. In the case of HFO-1234ze(E) in the CART-ZE/ZEI series, the factor becomes nearly 1.3. Therefore, it is normally necessary to increase the volume of components such as the compressor, evaporator, condenser, and gas pipes through which gaseous refrigerant passes. If this were the case, however, it would be impossible to replace the earlier models, making them useless as alternative new models. To enable the new models to be widely accepted, we have employed the following component designs to realize efficiency and compactness equivalent to or surpassing existing models. (1) Improved performance and compactness of the compressor [i] Aerodynamic design To deal with an increased specific volume of gaseous refrigerant, we have adopted an aerodynamic design that can withstand a larger gas flow than the existing compressors. However, because of the tendency for the increased design gas flow to impair the adiabatic efficiency, the blade shape of the impeller and the shape of the inlet guide vanes have been optimized using computational fluid dynamics (CFD) analysis. As a result, we have successfully increased the gas flow by 60% while improving the adiabatic efficiency by 3% with the same impeller radius as the existing compressors. The volume of the compressor has thus been reduced. [ii] Direct coupling of compressor and motor (ETI-Z series only) When the cooling capacity remains the same but the refrigerant has a higher specific volume, the impeller radius needs to be increased. An increased peripheral velocity of the impeller decreases the number of impeller rotations. For these reasons, we coupled the impeller directly with the motor. Consequently, the motor has been downsized and provides an increased rotational speed. Direct coupling of the compressor and the motor with no increasing gears in between has enabled the downsizing and improved performance of the compressor. The decreased number of bearings in the compressor has reduced the loss and improved the reliability. (2) Improved performance and compactness of the heat exchanger For the heat exchanger, the shell and tube type is used. Since the specific volume of refrigerant is larger and the pressure difference between the condenser and the evaporator is smaller than the existing chillers, we have designed the heat exchanger to minimize the pressure loss owing to the flow of refrigerant. Of particular focus are the prevention of drying, which makes it difficult for heat to be exchanged in heat exchanger tubes (owing to the locally

enlarged volume of gaseous refrigerant in the evaporator), the prevention of refrigerant liquid droplets being carried with gaseous refrigerant into the compressor because of the large flow rate of gaseous refrigerant bursting from the outlet above the tube bundle, and the prevention of a large pressure loss In the ETI-Z series, because some components such as the evaporator operate under working pressure conditions below atmospheric pressure, irregularities such as insufficient air-tightness can cause air (non-condensable gas) to enter the centrifugal chillers. Therefore, we have identified where such gases can collect and accordingly have installed tubes to extract them effectively when needed. (3) Small control panel with improved performance The control panel contains the microcontroller board with a CPU with an increased processing speed, thus enabling the control with higher accuracy. Moreover, the operability of the touchscreen and the visibility of the control panel have been improved, along with an increase in the size of the liquid crystal display compared with the previous models (Figure 4). The functionality has also been improved. In the case of irregular shutdowns due to chiller malfunctions, the procedure to be taken is shown on the screen as an operational support guide. It also gives automatic notifications such as regular maintenance schedules. In the large-capacity GART-ZE/ZEI series, the touchscreen display is placed separately from the electric device cabinet, thus providing even better operability. 7 Figure 4 Control panel screen (ETI-Z series) 5. Comparison with earlier models As examples, the ETI-Z series using HFO-1233zd(E) are compared with the previous models of the ETI series using HFC-134a (Figure 2). These two refrigerants have considerably different physical properties from each other. Table 2 Rated specifications and performance comparison ETI series ETI-Z series Chiller model ETI-20 ETI-Z20 Refrigerant HFC-134a HFO-1233zd(E) Cooling capacity 200 RT(703 kw) Chilled water temperature 12.0 C 7.0 C Chilled water flow rate 120.7 m 3 /h Cooling water temperature 32.0 C 37.0 C Cooling water flow rate 141.5 m 3 /h 139.6 m 3 /h Power consumption 115.0 kw 111.3 kw COP 6.1 6.3 L W H 3.7m 1.5m 1.8m 3.8m 1.6m 1.8m Space for installation 5.55 m 2 5.80 m 2 Shipping weight 3.9 ton 4.3 ton

(1) Performance While the ETI series (ETI-20) has a COP of 6.1, the COP of the ETI-Z series (ETI-Z20) is 6.3 (an increase of about 3%). The rated performance has thus improved. (2) Installation space In addition to the downsizing of the compressor and heat exchanger (as described in Section 4), a compact design has also been achieved by arranging the auxiliary devices and small containers beneath the condenser. Compared with the ETI series, the specific volume of gaseous refrigerant in the ETI-Z series is increased by nearly a factor of 5, but the required space for installation is increased by only about 5%. On the other hand, the GART-ZE/ZEI series successfully retains the compactness of the GART series. In both the ETI-Z and GART-ZE/ZEI series, a reduction of approximately 35% in installation space has been realized compared with our old models released 15 or more years ago, which are ready for to be replaced. 6. Maintenance and management It is essential to carry out daily maintenance and management for the safe and effective operation of centrifugal chillers. The following are the characteristics of the ETI-Z series (using HFO-1233zd(E)) and the GART-ZE/ZEI series (using HFO-1234ze(E)). (1) ETI-Z series As HFO-1233zd(E) has a low design pressure (saturation pressure of less than 0.2 MPaG when used for air conditioning) and is not subject to the High Pressure Gas Safety Act, there is no need for users to be trained for safety and emergency procedures, to conduct regular voluntary examinations and legally required inspections, or appoint someone as a safety superintendent for centrifugal chiller operation. Even if there are no such requirements, it is necessary to properly manage maintenance for the realization of the safe operation and stable performance of chillers (e.g., water quality control for chilled water and cooling water, and electrical parts replacement). We will proactively support users by providing regular inspections and listing the examination items. (2) GART-ZE/ZEI series Since HFO-1234ze(E) is subject to the High Pressure Gas Safety Act, this series should be managed as with the earlier models with HFC-134a. According to the above Act, HFO-1234ze(E) is classified as a designated inert gas, which necessitates the installation of a mechanical ventilation system (interlocking mechanism between the chiller and the ventilator) with a prescribed ventilation capacity, as well as a refrigerant leak detection and alarm system. 7. Conclusion HFO-1233zd(E) and HFO-1234ze(E) have a very low GWP of 1 or less (the GWP of CO 2 is 1). By applying these refrigerants to the new centrifugal chillers, all our centrifugal chiller models are now available with low GWP refrigerants. At present, there is no heat source or heatsink equipment with the use of a low GWP refrigerant in multi-split building air conditioners, which operate in a large-scale unit air-conditioning system. In the centralized air conditioning system, our centrifugal chillers with these refrigerants are the only products available among our domestic competitors. We will promote these new refrigerants to be widely recognized and continue to provide chillers that can satisfy our customers. 8 References 1. Naoya Miyoshi, Centrifugal Chiller Using HFO-1233zd(E), JRAIA The International Symposium on New Refrigerants and Enviromental Technology 2016