Environmental Chambers

Similar documents
Environmental Chambers

& Freezers. Selection Guide. Laboratory Refrigerators & Freezers. Accessories & Options

Elmatik AS, Türi 9, Tallinn Estonia tel tel fax

Compact design for personal use Ready to network with your computer.

Utility. Small size & light weight. Compact design with high performance SH-661. Select your optimum chamber from a full variation

Ovens. General Applications. Forced Convection Ovens. Natural Convection Ovens. Vacuum Ovens. Clean Ovens, Class 100

OVENS Forced Convection Ovens. Economy Forced Convection Ovens. Vacuum Ovens.

Faster Temperature (& Humidity) Chamber

External and internal circulation with powerful pumping capability

Natural convection, Film type heater. Amb. +3 to 60 / Amb to , 0.3, 0.1 at 37 / 0.36, 0.54, 0.18 at 98.6

Recirculating Coolers

Digital incubating/ refrigerating benchtop shakers

Constant climate chambers

Performance. TCC-150 provides uniform temperature load, and highlyrepeatable temperature change rate. Conformity to JEDEC JESD22-A104-B standard test

Constant climate chambers

Natural convection, Film type heater. Amb. +3 to 60 / Amb to , 0.3, 0.1 at 37 / 0.36, 0.54, 0.18 at 98.6

KMF Environmental test chamber for constant climate

Plant growth chambers

Environmental Stress Chamber AR series

Constant climate chambers. KBF 240 (E5.2) - Constant climate chamber. Performance features and equipment:

Thermal Shock Chamber TSE 11

Bench-Top Type Temperature (& Humidity) Chamber

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

Constant climate chambers

Constant climate chambers

Constant climate chambers

Faster Temperature (& Humidity) Chamber

TESTING FITOTERM FITOCLIMA TEMPERATURE / HUMIDITY CONTROL REACH-IN ENVIRONMENTAL CHAMBERS FOR CLIMATE AND TEMPERATURE TESTING

Environmental simulation chamber for complex alternating climate profiles

Compact Ultra Low Temperature Chamber

FITOCLIMA ECV45 / ECV75 TEMPERATURE & HUMIDITY TEST CHAMBER INTEGRATION WITH ELECTRO-DYNAMIC SHAKER

Platinous. temperature. and humidity. chambers. Top Quality Design. With an Easy-to-use. Touch-Screen. Programmer

Constant climate chamber with humidity

TEMPERATURE AND HUMIDITY TEST CHAMBER LTHC-A1 SERIES

Constant climate chamber with ICH-compliant illumination

New Generation KBF 240 series

Series of all-purpose physical and chemical environmental cabinets meeting the diverse needs of laboratories and research facilities.

Constant climate chambers

HOT AIR OVEN. NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

CLIMATIC TEST CHAMBER CTC / TEMPERATURE TEST CHAMBER TTC 100 % AtmoSAFE: In Memmert environmental

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

TESTING FITOTERM FITOCLIMA TEMPERATURE / HUMIDITY REACH-IN CHAMBERS FOR ENVIRONMENTAL TESTING

Walk in Steam Curing Chamber for Concrete Application. Detailed Working Specifications


Liquid to Liquid Thermal Shock Chamber TSB 21 TSB 51

OPERATION MANUAL. StableTemp Economy Mechanical Convection Oven. Model : ,-90,-91,-92,-93,-94

Constant climate chambers

Elmatik AS, Türi 9, Tallinn Estonia tel tel fax

Temperature Control Systems

Elmatik AS, Türi 9, Tallinn Estonia tel tel fax

Industrial Freezer Sales A division of IDS 5311 Derry Avenue Building D Agoura Hills CA Phone (818) Fax (818)

Model CB 220 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

Refrigerated Incubators / Environmental Testing Chambers

OVENS. All our ovens are tested to meet electrical safety standard IEC EN , this standard provides additional security for laboratories.

Utility. High performance by special glass. Supports high-temperature, high-humidity testing

EC 160 CO 2. Incubator

UMWELTSIMULATION TEMPERATUR VARIO. Walk-in chambers in modular design for multifunctional applications in different industrial fields

Climate chambers with illumination and humidity The BINDER KBWF series shines with its

Plant Growth Humidity Chamber

FITOCLIMA 600 & 1200 STABILITY

FROILABO offers a full range of incubators with natural convection, air forced or forced cooling to cover most laboratory applications.

Technical Specification of High and Low Temperature Altitude Test Chamber

FitoClima / FitoTerm SOL chambers

STABILITY. Stability Storage Chambers & Environmental Stability Rooms

STABILITY ICH. ICH Stability Tests

FITOCLIMA 600 & 1200 STABILITY

FITOCLIMA 600 & 1200 PHARMA

Model KBF 240 Constant climate chambers with large temperature / humidity range

Laboratory refrigerators and freezers

Temperature Controllers

Model KBWF 720 Growth chambers with light and humidity

Laboratory thermostatic chambers

NEW! Thermo Scientific Revco PLUS -86 C Freezers. Protecting Your Life s Work

Model C 170 CO 2 incubators with hot air sterilization

Auto Technology Company Cyclic Corrosion Test Chamber

VD 53 - Vacuum drying oven for non-flammable solvents

VWR symphony CO 2 INCUBATORS

Sterilizer. Yamato Scientific America. Contents. Innovating Science for Over 125 Years. Sterilizer Overview. Page

FITOCLIMA 600 & 1200 BIO

Ultra Deep Freezers -86 C. Biomedical Refrigeration I UF. Technology for life _8pages_dometic_UF.indd 1 10/09/08 11:17:32

ENVIRONMENT FRIENDLY CLIMATIC CHAMBER

CO 2. Incubators. Incubator, the first microprocessor-based system, and the first menu-driven control system, but we offer the

SX65 and SX75. Electronic process controllers

FitoClima 600 PDH. Climatic Chamber specially developed for reaching low humidity levels DC013EN/03

Smart Oven (SWOF / SWON model) Oven (WOF / WON model) Precise Vacuum Oven (WOV model)

Reproducible Climate...

The best test chambers...

Model KBF 1020 Constant climate chambers with large temperature / humidity range

Sunrise the beginning of a brand new day

Model KBWF 240 Growth chambers with light and humidity

Incubators, cooled incubators, drying ovens, sterilizers, climatic chambers

Benchtop Test Chambers Temperature and Humidity

The best test chambers...

Stability & Shelf Life

Stability Chambers & Rooms

CONTENTS >> VACUUM OVEN. General Description. Shelves Detail. Vacuum Drying Oven. -Feature. -Specification. 350 Vacuum Drying Oven.

Model KMF 115 Constant climate chambers with expanded temperature / humidity range

Heated and Refrigerated Incubators

Technical Description. Laboratory Climate Test Chamber. System Weiss. Mat. No.: Type WKL 34/40

ULTRA.GUARD ultra low temperature freezer

Transcription:

Temperature (& ) Chambers Dimensions (TH-G / TH-I / TC-G series) 115 Models Capacity W D H A B TH-G TH-I TC-G TH-G TC-G 180L (6.4cu ft) 1025mm (40.4 ) 1035mm (40.7 ) 1530mm (60.2 ) 450mm (17.7 ) 1230mm (48.4 ) 300L (10.6cu ft) 1120mm (44.1 ) 1070mm (42.1 ) 1730mm (68.1 ) 450mm (17.7 ) 1230mm (48.4 ) 408L (14.4cu ft) 1120mm (44.1 ) 1240mm (48.8 ) 1730mm (68.1 ) 520mm (20.5 ) 1230mm (48.4 ) 800L (28.3cu ft) 1570mm (61.8 ) 1245mm (48.8 ) 2060mm (81.1 ) 490mm (19.3 ) 1260mm (49.6 ) 1000L (35.3cu ft) 1570mm (61.8 ) 1445mm (56.9 ) 2060mm (81.1 ) 560mm (22.0 ) 1260mm (49.6 ) 1500L (53.0 cu ft) 1570mm (61.8 ) 2045mm (80.5 ) 2050mm (80.7 ) 560mm (22.0 ) 800mm (31.5 ) Temperature & control range (TH series only) Relative % RH 98%RH 95%RH TH-G type (180, 300, 408L) TH-GU-300 40 ~ 85% RH at 15 25 ~ 98% RH at 25 ~ 80 25 ~ 80% RH at 90 TH-G-800/1000/1500 TH-G-180/300/408, TH-GU-300 TH-I-180/300/408 TH-G type (800, 1000, 1500L) 50 ~ 90% RH at 20 45 ~ 95% RH at 25 40 ~ 95% RH at 30 ~ 80 40 ~ 80% RH at 90 TH-I type (180, 300, 408L) Temperature 30 ~ 80% RH at 10 20 ~ 90% RH at 20 20 ~ 98% RH at 25 ~ 80 20 ~ 80% RH at 90

Temperature (& ) Chambers 116 Operating & Constructional features Door Catch & Trim Color LCD Controller User-friendly design Standard environmental test chambers. High quality #304 stainless steel exterior and interior. Casters for easy mobility when installing or moving environmental test chamber. Convenient maintenance-available to view total operating time. Spacious chamber volume maximum capacity of 1500L. Choose from 15 different model chambers based on size and temperature preference. - The series comes in 3 different model types based on temperature (&humidity) ranges ranging in -35 to 150, -35 to 120, -60 to 150 / upmost 20 to 98% RH and five different volume capacities of 180L, 300L, 408L, 800L, 1000L and 1500L. Unique door lock & trim. - Vice lock type door and foam silicone packing to ensure a perfect seal. - Door open warning alarm. Inner door. - Optional inner glass door comes with four holes to handle samples inside the chamber. (Excludes chambers with volume capacities of 800L or 1500L) Ventilation. - Ventilation vent is located at the upper right side of the unit. Chart recorder. (optional) - 6-point dot type recorder with a digital display. Container type tank for easy adding and changing of water. - Maintenance of the water tank can be easily performed from the front side. - Checking of the water level and the amount of water remaining in the tank can be performed by looking through the center viewing window. Viewing window for observation. - Tempered glass window provides a clear view of samples in the chamber, beneficial during testing. - Fluorescent lighting source included. Cable port for external probes or wires. - 50mm diameter cable port comes standard on the left side of the unit. Additional 50mm or 80mm diameter cable ports can be custom ordered. (Optional) Easy cleaning of condenser air-filter. - To prevent deterioration of refrigeration system and keep filter dust free by periodically cleaning the filter. Safety functions Digital Recorder (optional) Leakage breaker for power supply. Over current protection. Overheat / overcool protection. Switch-off after alarm for over heating. Water empty alarm. (TH-G / TH-GU / TH-I only) Door open alarm. Vice lock door type locking mechanism.

Temperature (& ) Chambers Control operation Microprocess PID control / Auto-tuning / Calibration. Chamber supports three different languages : English, Chinese, and Korean. Optimize CPU logic control system. - Optimum control of temperature / humidity with economical power consumption. Touch screen type display. - 5.7-inch Color LCD display with interactive input system. : Easily visible set value: set point (SP) /present value (PV) are also added on the colorful LCD controller. - Temperature & humidity / timer settings and operation condition. - Temperature, humidity, and other operating parameters can be recorded using a chart recorder. Programming operation. 117 Description TH-G, I, GU / TC-G, GU series Programmable pattern capacity 120 Pattern repeat time 999 Max. segments per a pattern 100 Available max. segments* 1200 Programmable process time per a segment 0 to 99 hr 59 min * Even though the max. segments per a pattern are 100, available total segments are up to 1200 not 12000, so you need to arrange the number of segment an patterns properly. Water Tank Computer interface. - Save data in excel format. - Software provided. - Storage of program information, backup of value settings / recovery, and temperature / humidity values. - RS-232C port as standard offer. RS-485 communication port offers connection of a maximum of 9 temperature & humidity chamber units to one PC. (optional) Air filter Multi-control Display Single-control Display Program setting Display Graph Display Ventilation

Temperature & Chambers 118 Specifications & Ordering Informations Model TH-G-180 TH-G-300 TH-G-408 TH-G-800 TH-G-1000 TH-G-1500 Chamber volume (L / cu ft) 180 / 6.4 300 / 10.6 408 / 14.4 800 / 28.3 1000 / 35.3 1500 / 53.0 Control system BDBC2 system - Balanced Dehumidifying & Bath Cooling control Controller Programmable, Touch screen type controller (5.7 Color monitor) Temperature Time Refrigeration Cooler Range (± / ) - without humidity Fluctuation 1) (± / ) at 55 / 60%RH Variation 1) (± / ) at 55 / 60%RH Heating - without humidity (Min.) Cooling - without humidity (Min.) Range (%RH) Fluctuation 1) (±%RH) at 60%RH / 55 Variation 1) (±%RH) at 60%RH / 55 System -35 to 150 / -31 to 302 * best programmable control range : -30 to 140 / -22 to 284-35 to 150 / -31 to 302 0.1 / 0.18 0.2 / 0.36 0.2 / 0.36 0.3 / 0.55 0.3 / 0.55 0.3 / 0.55 0.6 / 1.08 0.5 / 0.9 0.5 / 0.9 0.5 / 0.9 0.5 / 0.9 0.5 / 0.9 50 From -35 to 120 (-31 to 248 ) 60 From -35 to 120 (-31 to 248 ) 60 From 20 to -35 (68 to -31 ) On singe point control * 40 to 85 at 15 (59 ) 50 to 90 at 20 (68 ) 25 to 98 at 25 to 80 (77 to 176 ) 45 to 95 at 30 to 80 (86 to 176 ) 25 to 80 at 90 (194 ) 40 to 80 at 30 to 90 (86 to 194 ) 0.3 0.4 0.3 0.5 0.6 3 Mechanical single stage refrigerator system (air-cooled condenser) 3.0 3.5 Mechanical dual stage refrigerator system (air-cooled condenser) Certification only for the TH-G-180. 300. 408 85 From 20 to -35 (68 to -31 ) Refrigerant R-404A R-404A (1st step), R-23 (2nd step) Capacity (W) 1500 4250 6000 Plate fin cooler Ni-Cr Wire Heater / SUS sheath Heater SUS Tube heater Heater Drying bulb (W) 2000 3000 5000 bulb (W) 1500 2000 3500 Sensor Temperature Pt 100 Electronic sensor - Free of drying a wet pack and good reaction time Interior Stainless steel #304 Exterior Stainless steel #304 Insulation Polyurethane foam 100mm (3.94 ) Door Glass wool Air flow Tangent blower (90W) 4 sets of sirocco fan (4 90W) Water supply Capacity 15L (0.53cu ft) - Cartridge type Direct water supplying system Water quality ph6.2 to 7.2 / Electrical conductivity 20 /cm to below Dimensions (W D H) Cable Port Interface Port Interior (mm / inch) Exterior (mm / inch) 500 630 600 / 19.7 24.8 23.6 1025 1035 1530 / 40.4 40.7 60.2 600 630 800 / 23.6 24.8 31.5 1120 1070 1730 / 44.1 42.1 68.1 600 850 800 / 23.6 33.5 31.5 1120 1240 1730 / 44.1 44.8 68.1 1000 800 1000 / 39.4 31.5 39.4 1570 1245 2060 / 61.8 49.0 81.1 1000 1000 1000 / 39.4 39.4 39.4 1570 1445 2060 / 61.8 56.9 81.1 1000 1000 1500 / 39.4 39.4 59.1 1570 2045 2050 / 61.8 80.5 80.7 Viewing windows (mm / inch) 200 330 / 7.9 13.0 270 330 / 10.6 13.0 Net weight (kg / lbs) 310±10 / 683.4±22.0 375±10 / 826.7±22.0 400±10 / 881.8±22.0 610±10 / 1345±22.0 670±10 / 1477±22.0 750±10 / 1653.5±22.0 Basically one hole provided / Ø50mm (2.0 ) Optionally max. two holes available / Ø50 or 80mm (2.0 or 3.2 ) Basically RS-232C [RS-485(Maximum 9 Units Control)-Optional] Electrical Requirements (230V, 60Hz) 1ph / 23.0A - - AAH80011 AAH80021 AAH80031 - - - Electrical Requirements (230V, 50Hz) 1ph / 23A 50Hz / 3ph / 22.5A 50Hz / 3ph / 37.7A AAH80012 AAH80022 AAH80032 AAH80042 AAH80052 AAH80072K Electrical Requirements (380V, 50Hz) 3ph / 7.7A 50Hz / 3ph / 13.0A 50Hz / 3ph / 20.6A AAH80018 AAH80028 AAH80038 AAH80048 AAH80058 AAH80078 1) Technical data. (according to DIN 12880, IEC 60068) Certification only for the TH-G-180 300 408 Permissible ambient Condition: Temperature 18 to 30 (64.4 to 86 ), Maximum relative humidity 85%. All specifications are under ambient temperature 20 (68 ), no load.

Temperature & Chambers Specifications & Ordering Informations Model TH-I-180 TH-I-300 TH-I-408 Chamber volume (L / cu ft) 180 / 6.4 300 / 10.6 408 / 14.4 Control system Controller Temperature Time Refrigeration Cooler Heater Sensor Air flow Water supply Dimensions (W D H) Range ( / ) Fluctuation 1) (± / ) at 55 / 60%RH Variation 1) (± / ) at 55 / 60% Heating - without humidity (Min.) BDBC2 system - Balanced Dehumidifying & Bath Cooling control Programmable, Touch screen type controller (5.7 Color monitor) -35 to 150 / -31 to 302 without humidity * best programmable control range : -30 to 140 / -22 to 284 0.1 / 0.18 0.2 / 0.36 0.2 / 0.36 0.6 / 1.08 0.5 / 0.9 0.5 / 0.9 50 From -35 to 120 (-31 to 248 ) Cooling - without humidity (Min.) 60 From 20 to -35 (68 to -31 ) on singe point control * Range (%RH) Fluctuation 1) (±%RH) at 60%RH / 55 Variation 1) (±%RH) at 60%RH / 55 System Refrigerant 30 to 80 at 10 (50 ) 20 to 98 at 20 to 80 (68 to 176 ) 20 to 80 at 90 (194 ) 0.3 0.4 0.3 3 3 3 Mechanical single stage refrigerator system (air-cooled condenser) R-404A Capacity (W) 1500 Plate fin cooler Ni-Cr Wire Heater / SUS sheath Heater Drying bulb (W) 2000 bulb (W) 1500 Temperature Pt 100 Interior Stainless steel #304 Exterior Stainless steel #304 Insulation Polyurethane foam 100mm (3.94 ) Door Capacity Water quality Interior (mm / inch) Exterior (mm / inch) Electronic sensor - Free of drying a wet pack and good reaction time Glass wool Tangent blower (90W) 15L (0.53cu ft) - Cartridge type ph6.2 to 7.2 / Electrical conductivity 20 /cm to below 500 630 600 / 19.7 24.8 23.6 1025 1035 1530 / 40.4 40.7 60.2 600 630 800 / 23.6 24.8 31.5 1120 1070 1730 / 44.1 42.1 68.1 600 850 800 / 23.6 33.5 31.5 1120 1240 1730 / 44.1 44.8 68.1 Viewing windows (mm / inch) 200 330 / 7.9 13.0 Net weight (kg / lbs) 310±10 / 683.4±22.0 375±10 / 826.7±22.0 400±10 / 881.8±22.0 Cable Port Basically one hole provided / Ø50mm (2.0 ) Optionally max. two holes available / Ø50 or 80mm (2.0 or 3.2 ) Interface Port Basically RS-232C [RS-485(Maximum 9 Units Control)-Optional] Electrical Requirements (230V, 60Hz) 1ph / 23.0A AAH80111 AAH80121 AAH80131 Electrical Requirements (230V, 50Hz) 1ph / 23.0A AAH80112 AAH80122 AAH80132 Electrical Requirements (380V, 50Hz) 3ph / 7.7A AAH80118 AAH80128 AAH80138 119 1) Technical data. (according to DIN 12880, IEC 60068) Permissible ambient Condition : Temperature 18 to 30 (64.4 to 86 ), Maximum relative humidity 85% All specifications are under ambient temperature 20 (68 ), no load.

Temperature & Chambers Specifications & Ordering Informations 120 Model TH-GU-300 Chamber volume (L / cu ft) 300 / 10.6 Control system Controller Temperature Time Refrigeration Cooler Heater Sensor Air flow Range ( / ) Fluctuation 1) (± / ) at 40 / 60%RH Variation 1) (± / ) at 40 / 60%RH Heating - without humidity (Min.) Cooling - without humidity (Min.) Range (%RH) BDBC2 system - Balanced Dehumidifying & Bath Cooling control Programmable, Touch screen type controller (5.7 Color monitor) -60 to 150 / -76 to 302 without humidity *best programmable control range : -50 to 140 / -58 to 284 0.3 / 0.54 0.5 / 0.9 60 From -60 to 120 (-76 to 248 ) 65 From 20 to -60 (68 to -76 ) on singe point control 40 to 85 at 15 (59 ) 25 to 98 at 25 to 80 (77 to 176 ) 25 to 80 at 90 (194 ) Fluctuation 1) (±%RH) 3 Variation 1) (±%RH) 3 System Mechanical single stage refrigerator system (air-cooled condenser) Refrigerant R-404A / R-23 Capacity (W) 3000 Plate fin cooler Ni-Cr Wire Heater / SUS sheath Heater Drying bulb (W) 2000 bulb (W) 1500 Temperature Pt 100 Electronic sensor - Free of drying a wet pack and good reaction time Interior Stainless steel #304 Exterior Stainless steel #304 Insulation Polyurethane foam 100mm (3.94 ) Door Glass wool Tangent blower (90W) Water supply Capacity 15L (0.53cu ft) - Cartridge type Water quality ph6.2 to 7.2/ Electrical conductivity 20 / cm to below Interior (mm / inch) 600 630 800 / 23.6 24.8 31.5 Dimensions Exterior (mm / inch) 1120 1070 1730 / 44.1 42.1 68.1 (W D H) Viewing windows (mm / inch) 200 330 / 7.9 13.0 Net weight (kg / lbs) 395±10 / 870.8±22.0 Cable Port Basically one hole provided / Ø50mm (2.0 ) Optionally max. two holes available / Ø50 or 80mm (2.0 or 3.2 ) Interface Port Basically RS-232C [RS-485(Maximum 9 Units Control)-Optional] Electrical Requirements (230V, 60Hz) 1ph / 23.0A AAH80321 Electrical Requirements (230V, 50Hz) 1ph / 23.0A AAH80322 Electrical Requirements (380V, 50Hz) 3ph / 7.7A AAH80328 1) Technical data. (according to DIN 12880, IEC 60068) Permissible ambient Condition: Temperature 18 to 30 (64.4 to 86 ), Maximum relative humidity 85%. Upon request, other sizes of chambers are available. Please contact with us. All specifications are under ambient temperature 20 (68 ), no load.

Temperature Chambers Specifications & Ordering Informations 122 Model TC-GU-300 Chamber volume (L / cu ft) 300 / 10.6 Control system Controller Temperature Time Refrigeration Cooler Heater Range ( / ) Cooling fuzzy control system Programmable, Touch screen type controller (5.7 Color monitor) -60 to 150 / -76 to 302 without humidity *best programmable control range : -50 to 140 / -58 to 284 Fluctuation 1) (± / ) at 40 0.3 / 0.54 Variation 1) (± / ) at 40 0.5 / 0.9 Heating (Min.) Cooling (Min.) System Refrigerant 60 From -60 to 120 (-76 to 248 ) 65 From 20 to -60 (68 to -76 ) on singe point control Mechanical single stage refrigerator system (air-cooled condenser) R-404A (1st step), R-23 (2nd step) Capacity (W) 3000 Plate fin cooler Ni-Cr Wire Heater Drying bulb (W) 2000 Temperature Sensor Pt 100 Interior Stainless steel #304 Exterior Stainless steel #304 Insulation Polyurethane foam 100mm (3.94 ) Door Glass wool Air flow Tangent blower (90W) Interior (mm / inch) 600 630 800 / 23.6 24.8 31.5 Dimensions Exterior (mm / inch) 1120 1070 1730 / 44.1 42.1 68.1 (W D H) Viewing windows (mm / inch) 200 330 / 7.9 13.0 Net weight (kg / lbs) 375±10 / 870.8±22.0 Cable Port Basically one hole provided / Ø 50mm (2.0 ) Optionally max. two holes available / Ø 50 or 80mm (2.0 or 3.2 ) Interface Port Basically RS-232C [RS-485(Maximum 9 Units Control)-Optional] Electrical Requirements (230V, 60Hz) 1ph / 24.3A AAH81521 Electrical Requirements (230V, 50Hz) 1ph / 24.3A AAH81522 Electrical Requirements (380V, 60 / 50Hz) 3ph / 8.3A AAH81528 1) Technical data. (according to DIN 12880, IEC 60068) Permissible ambient Condition: Temperature 18 to 30 (64.4 to 86 ), Maximum relative humidity 85%. All specifications are under ambient temperature 20 (68 ), no load.