Bench-Top Type Temperature (& Humidity) Chamber

Similar documents
Utility. Small size & light weight. Compact design with high performance SH-661. Select your optimum chamber from a full variation

Faster Temperature (& Humidity) Chamber

Compact design for personal use Ready to network with your computer.

Environmental Stress Chamber AR series

Thermal Shock Chamber TSE 11

Compact Ultra Low Temperature Chamber

Faster Temperature (& Humidity) Chamber

Bench-Top Type Temperature (& Humidity) Chamber

Performance. TCC-150 provides uniform temperature load, and highlyrepeatable temperature change rate. Conformity to JEDEC JESD22-A104-B standard test

Liquid to Liquid Thermal Shock Chamber TSB 21 TSB 51

Series of all-purpose physical and chemical environmental cabinets meeting the diverse needs of laboratories and research facilities.

Utility. High performance by special glass. Supports high-temperature, high-humidity testing

Elmatik AS, Türi 9, Tallinn Estonia tel tel fax

Utility. Improved functionality and ease-of-use for bias testing. The chamber interior is formed for easier specimen loading

Thermal Shock Chambers TSA Series

Elmatik AS, Türi 9, Tallinn Estonia tel tel fax

Thermal Shock Chambers

Elmatik AS, Türi 9, Tallinn Estonia tel tel fax

Temperature Chamber Series

Environmental Stress Chamber

Temperature Chamber Series

Thermal Shock Chambers

Benchtop Test Chambers. Temperature and Humidity

Environmental Chambers

Chapter 5 Inspection and maintenance

Platinous J Series CAT.NO.E15110-Y1612

Environmental Stress Chamber

Battery Charge/Discharge Test System Integrated with Temperature Chamber

Environmental Chambers

Advanced Test Equipment Rentals ATEC (2832) Temperature Cycling Chambers Global-N Series

Highly Accelerated Stress Test System (HAST Chamber)

Walk-In Type Temperature (& Humidity) Chamber E Series

Platinous. temperature. and humidity. chambers. Top Quality Design. With an Easy-to-use. Touch-Screen. Programmer

Chapter 5 Inspection and maintenance

The best test chambers...

Chapter 8 Troubleshooting

Chapter 8 Troubleshooting

Refrigerated Incubators / Environmental Testing Chambers

Temperature Cycling Chambers Global-N Series

Benchtop Test Chambers Temperature and Humidity

Water Circulator (Chiller) & Cold Trap

Technical Specification of High and Low Temperature Altitude Test Chamber

Customized Industrial Products

The best test chambers...

DOUBLE DOOR FREEZER.

Walk-In Type Temperature (& Humidity) Chamber E Series

Constant climate chambers

Stability & Shelf Life

Constant climate chambers

Constant climate chamber with humidity

Technical Description. Laboratory Climate Test Chamber. System Weiss. Mat. No.: Type WKL 34/40

Constant climate chamber with ICH-compliant illumination

Daily maintenance and checks

MINI BENCH TOP CHAMBER MODEL: MI-80-A-H

Heated and Refrigerated Incubators

DAIKIN Modular Inverter Air Cooled Chiller

Products for Secondary Battery Market

Constant climate chambers

Chapter 7 Checks and Maintenance

Sterilizer. Yamato Scientific America. Contents. Innovating Science for Over 125 Years. Sterilizer Overview. Page

BLOOD BANK REFRIGERATOR - BR Series

Constant climate chambers. KBF 240 (E5.2) - Constant climate chamber. Performance features and equipment:

MOV Series Electric Ovens Dry Heat Sterilizers MOV-112F/212F MOV-112/212 MOV-112S/212S MOV-112F MOV-212

BUSINESS SOLUTIONS. Biomedical REFRIGERATORS & FREEZERS FOR BIOMEDICAL NEEDS

Thermo Scientific Heraeus Heating and Drying Ovens

Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated

ISO-9001:2008 FURNACES CATALOG. Phone: Fax: Web:

HOT AIR OVEN. NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

Laboratory Refrigerator/Deep Freezer TC 802

FAST CHANGE RATE AND DRIVE-IN CHAMBERS FOR AUTOMOTIVE TESTING. by ESPEC North America Inc

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

CLIMATRON GROWTH CABINETS

Medical Air circulated Refrigerator TC (2 independent temperature ranges), also in accordance with DIN 58345

January Engineering Data RXSQ24-60TAVJU. Heat Pump 208/230V / 60 Hz / 1 ph. Presales Manual DAIKIN NORTH AMERICA LLC

HettCube INCUBATORS SUSTAINABLE. ERGONOMIC. HIGH QUALITY. INCUBATOR. Find out more by visiting:

Drying and heating chambers. Series ED FD FED FP M

Environmental simulation chamber for complex alternating climate profiles

INSTALLATION and OPERATION INSTRUCTIONS

Sub psi SPECIFICATIONS

LABOKLAV. Autoclaves Made in Germany

All series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly.

Recirculating Coolers

Installation & Operation Manual

Protection, safety, reliability. And more.

-86ºC-Freezer. Ultra-Low Temperature Chest freezers: MDF-792 MDF-592 MDF-492 MDF-392 MDF-293 MDF-192

Climate chambers with illumination and humidity The BINDER KBWF series shines with its

Fisher Scientific Isotemp Muffle Furnace 550 Series. Instruction Manual

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

FUNCTION LINE HEATING AND DRYING OVENS

AIRSYS-P-SC-CHILLROW-E1503V01.1 CHILLROW. Row Cooling Precision Air Conditioner. Cooling Capacity: 26.2kW~68.6kW

Refrigerators. Upright Blood Bank. i.series Horizon Series

Laboratory & Pharmacy Refrigerators

Freezers. Upright Laboratory & Plasma. i.series Horizon Series

KMF Environmental test chamber for constant climate

Digital incubating/ refrigerating benchtop shakers

CONTENTS >> VACUUM OVEN. General Description. Shelves Detail. Vacuum Drying Oven. -Feature. -Specification. 350 Vacuum Drying Oven.

BATHS SHAKERS STIRRERS HOTPLATES INCUBATORS HEATING MANTLES INCUBATORS

Ultra low temperature freezers for long-term storage at -86 C UF V 500, UF V 700

TEMPERATURE AND HUMIDITY TEST CHAMBER LTHC-A1 SERIES

Vacuum drying VD VDL series

Transcription:

Bench-Top Type Temperature (& Humidity) Chamber SHSU CAT.NO.E01111-M102

Compact design for personal use, to network with your computer. The Bench-top Type Temperature (& Humidity) Chamber Series features environmental testing performance in a compact design. Available in 20L and 60L capacities, these models offer temperature ranges as low as 20, 40, or 60, and achieve excellent performance rates, as well as communication interface compatibilities to collect test data. Espec offers you the best in terms of advanced testing equipment. 1

* The viewing window is optional. 2

Utility Light and small structure The chamber structure is optimized to save space while offering a wide test area (22.5L for 1st model). Its relatively light weight allows setup almost everywhere. (78kg_ SU-221 / 241 models) Test area (60L model) Full-size chamber performance in a compact design The SH-661 model achieves 60 to 150 temperature range and 30 to 95rh for humidity in a small structure. It shows undoubtedly better performance than any other previous bench-top model. Full variation to select from With 3 different temperature range patterns (20, 40, or 60), and 2 sizes (20 and 60L), the Bench-top chamber series offers 10 models with either temperature or temperature/ humidity configurations, to fulfill customers' needs. Ion migration evaluation The Bench-top chamber can be combined with ESPEC's Ion Migration Evaluation System (AMI) to ensure even more accurate evaluation results. Stacked chambers (on stands) With its 3 temperature range patterns (to 60, 40 or 20), and 2 volumes (20 and 60L) selection, the Bench-top chambers offer 10 models in temperature or temperature/ humidity configuration, to fulfill customers' needs. 3 Example: Bench-top Type Temperature (& Humidity) Chamber connected with the Ion Migration Evaluation System (sold separately)

Eco-friendly A refrigeration system that reduces energy consumption by 55 Our exclusive refrigerator system with capacity control achieves 55 reduction in power consumption compared to our previous model. (SH/SU-221241 models) Layout arrangement thanks to additional stand (option) L and H stands are equipped with casters, and allow easy storage to optimize your testing zone. L stand is lower to fit under H stand and stack chambers. (L=Low, H =High) * It is recommended to secure stands to the floor with provided anchor bolts. Material labeling for easy recycling Plastic molded components are labeled and easily detachable to make recycling easier for future disposal of the equipment. Stands (option) Paperless recorder (option) Portable type, to record temperatures from various sources, such as test area temperature. Recording is possible on Compact Flash Card or via USB port. Cable port plug (Material marked) Paperless recorder Portable type (option) 4

User-friendly Easy wiring access The chamber features free access to the test area. Cable ports are provided on both right and left side to allow easy wiring of specimens for measurement or voltage application. Easy water supply Water is supplied from the front side tank (equipped with a level sensor). Auxiliary water tank circuit (option) is also available for extended operation time. (SH model) Right-opening door (option) The door opening can be reversed to fit your installation space. Viewing window (option) An optional viewing window can be added to check specimens and wiring during testing. (W215H215mm for 20L model, W215H315mm for 60L model) Water supply tank Right-opening door (option) Viewing window (option) 5

Control operation Key input setting Easy setting of temperature and humidity values, but also upper and lower temperature (& humidity) limit alarms, by mechanical key input. Program operation up to 9 steps Besides constant setting, program operation is available by setting different patterns (9 step/ pattern) of heat up and pull down temperatures, to meet requirements of temperature characteristic test or temperature (& humidity) cycling. The instrumentation additionally offers various functions. Flexible communication interface An RS-485 connector is equipped as standard, but RS-232C or GP-IB is also available as option. Remote control from your PC Please contact us for details on using a PC to monitor and remotely control the equipment. Description of program function Program function Step program Temperature gradient program Termination program Pattern *1 Sets a program repetition frequency between a range of 1 and 99. *2 Selects HOLD, CONST or OFF when a program is over. 1 1 *1,2 Time *1,2 Time 1.HOLD 2.CONST 3.OFF Retains value of last step END 2 3 3 4 2 4 5 5 6 6 END 7 Operation at constant temp. Chamber OFF END Time Time Time Temperature (& humidity) program indicator controller Setting Mechanical key input Display 7 segment LED display Operating mode Program operation, constant operation Control PID control : 0.1ºC Setting and indication Humid. : 1%rh (SH only) Time : 1 minute : 25 to 155ºC (SH-221, SU-221) 45 to 155ºC (SH-241/641, SU-241/641) Setting and 65 to 155ºC (SH-261/661, SU-261/661) indication ranges Humid. : 0 to 100%rh (SH only) Time : 0 to 99 hours 59 minutes, 100 to 999 hours : 0.5ºC (Typ.) Indication accuracy * Humid. : 2%rh (Typ.) (SH only) Time : within 30 sec. per month Program memory capacity 9 steps per pattern (1 to 99 times) Communication RS-485 Input-burnout detection Upper and lower temp. (& humid.) limit alarm Self-diagnostic (watchdog timer) Auxiliary functions Alarm indication Power cut protection Refrigerator capacity automatic control Battery Lithium battery 1 * At ambient temperature 23ºC 7 8 8 9 9 6

SH 7 Model SH 221 SH 241 SH 261 SH 641 SH 661 System Performance *1 Construction range *2 Humidity range *2 fl uctuation *2 Humidity fl uctuation *2 uniformity *2 20 to 150 (4 to 302) Balanced Temperature & Humidity Control system (BTHC system) 40 to 150 (40 to 302) 60 to 150 (76 to 302) 30 to 95rh 40 to 150 (40 to 302) 60 to 150 (76 to 302) 0.3 (20 to 100) 0.54 (4 to 212) 0.5 (100.1 to 150) 0.3 (40 to 100 ) 0.54 (40 to 212) 0.5 (100.1 to 150 ) 0.3 (60 to 100 ) 0.54 (76 to 212) 0.5 (100.1 to 150 ) 0.3 (40 to 100 ) 0.54 (40 to 212) 0.5 (100.1 to 150 ) 0.3 (60 to 100 ) 0.54 (76 to 212) 0.5 (100.1 to 150 ) 0.9 (212.1 to 302) 0.9 (212.1 to 302) 0.9 (212.1 to 302) 0.9 (212.1 to 302) 0.9 (212.1 to 302) 3.0 0.5 (20 to 100 ) 0.5 (40 to 100 ) 0.5 (60 to 100 ) 0.5 (40 to 100 ) 0.5 (60 to 100 ) 0.9 (4 to 212) 0.9 (40 to 212) 0.9 (76 to 212) 0.9 (40 to 212) 0.9 (76 to 212) 0.8 (100.1 to 150 ) 0.8 (100.1 to 150 ) 0.8 (100.1 to 150 ) 0.8 (100.1 to 150 ) 0.8 (100.1 to 150 ) 1.44 (212.1 to 302)1.44 (212.1 to 302)1.44 (212.1 to 302)1.44 (212.1 to 302)1.44 (212.1 to 302) Humidity uniformity *2 3.0 heat up time 20 to 150 within 55 min. 40 to 150 within 60 min. 60 to 150 within min. 40 to 150 within min. 60 to 150 within 80 min. pull down time *3 20 to 20 within 20 min. 20 to 40 within 50 min. 20 to 60 within min. 20 to 40 within 60 min. 20 to60 within 90 min. Lowest attainable temp. *3 20 (4) 40 (40) 60 (76) 40 (40) 60 (76) Exterior material Interior material Insulation Door Heater Humidifi er Refrigeration unit Cold-rolled rust-proofed steel plate 18-8 Cr-Ni Stainless steel plate (2B fi nish) Rigid polyurethane foam, glass wool Manually operated door with lock (hinge on left, handle on right) Nichrome strip wire heater Sheathed heater System Mechanical single-stage refrigeration system Mechanical cascade refrigeration system (air-cooled condenser) Refrigerator Hermetically sealed compressor Refrigerator capacity 400W [Unit 1: 400W 1, Unit 2: 400kW 1] Expansion mechanism Capillary tube system Refrigerant R404A R23, R404A Cooler Plate fi n cooler Air circulator Propeller fan Cable port ID 25mm (2), specimen power supply control terminal, temperature-humidity recorder terminal, Fittings external alarm terminal, external output terminal, power cable, water tank, drain hose, plug for humidifying tray drainage, socket for water tank level sensor drain Capacity L 22.5 64 Chamber total load resistance kg 20 Inside dimensions mm (inch) W300H300D250 (W11.81H11.81D9.84) W400H400D400 (W15.75H15.75D15.75) Outside dimensions mm (inch) W440H630D695/722 (W17.32H24.80D27.36/28.43) W440H690D785/812 (W17.32H27.18D30.91/31.97) W540H730D920/930 (W21.26H28.74D36.22/36.61) Weight kg 83 (78 for 100V type) 105 130 Allowable ambient conditions 5 to 35 (41 to 95 Utility requirements Power supply *4 100V AC 150/60Hz 13.5 A 15.0 A 18.0 A 115V AC 160Hz 13.0 A 14.5 A 200V AC 150/60Hz 10.5 A 220V AC 150/60Hz 8.0 A 9.5 A 10.0 A 230V AC 150Hz 7.5 A 9.5 A 10.0 A CE marking Noise level *5 db 55 59 61 Exhaust heat quantity 3500 (836) 4000 (955) 5040 (1204) kj/h (kcal/h) *1 At ambient temperature 23, with no specimen. Lowest attainable temperature performance guaranteed to max. 30. (ambient temp.) *2 Performance shown above conforms to JTM K01-1998 *3 At ambient temperature above 32 (30 for SH-221/241), temperature pull down performances decrease and the difference between each chamber increases. It is recommended to keep ambient temperature to a maximum of 30 (28for SH-221/241) *4 At ambient temperature 23. For SH-641/661, make sure to check the power capability of your installation beforehand. *5 Measurements are to be taken in an anechoic room at a height of 1.2m from the fl oor and a distance of 1m from the chamber front panel (ISO 1996-1:2003 _ A-weighted sound pressure level)

SU Model SU 221 SU 241 SU 261 SU 641 SU 661 System Performance *1 range *2 fl uctuation *2 uniformity *2 20 to 150 (4 to 302) Balanced Temperature Control system (BTC system) 40 to 150 (40 to 302) 60 to 150 (76 to 302) 40 to 150 (40 to 302) 60 to 150 (76 to 302) 0.3 (20 to 100) 0.54 (4 to 212) 0.5 (100.1 to 150) 0.3 (40 to 100 ) 0.54 (40 to 212) 0.5 (100.1 to 150 ) 0.3 (60 to 100 ) 0.54 (76 to 212) 0.5 (100.1 to 150 ) 0.3 (40 to 100 ) 0.54 (40 to 212) 0.5 (100.1 to 150 ) 0.3 (60 to 100 ) 0.54 (76 to 212) 0.5 (100.1 to 150 ) 0.9 (212.1 to 302) 0.9 (212.1 to 302) 0.9 (212.1 to 302) 0.9 (212.1 to 302) 0.9 (212.1 to 302) 0.5 (20 to 100 ) 0.5 (40 to 100 ) 0.5 (60 to 100 ) 0.5 (40 to 100 ) 0.5 (60 to 100 ) 0.9 (4 to 212) 0.9 (40 to 212) 0.9 (76 to 212) 0.9 (40 to 212) 0.9 (76 to 212) 0.8 (100.1 to 150 ) 0.8 (100.1 to 150 ) 0.8 (100.1 to 150 ) 0.8 (100.1 to 150 ) 0.8 (100.1 to 150 ) 1.44 (212.1 to 302)1.44 (212.1 to 302)1.44 (212.1 to 302)1.44 (212.1 to 302)1.44 (212.1 to 302) heat up time 20 to 150 within 55 min. 40 to 150 within 60 min. 60 to 150 within min. 40 to 150 within min. 60 to 150 within 80 min. pull down time *3 20 to 20 within 20 min. 20 to 40 within 50 min. 20 to 60 within min. 20 to 40 within 60 min. 20 to60 within 90 min. Lowest attainable temp. *3 20 (4) 40 (40) 60 (76) 40 (40) 60 (76) Construction Refrigeration unit Exterior material Cold-rolled rust-proofed steel plate Interior material 18-8 Cr-Ni Stainless steel plate (2B fi nish) Insulation Rigid polyurethane foam, glass wool Door Manually operated door with lock (hinge on left, handle on right) Heater Nichrome strip wire heater System Mechanical single-stage refrigeration system Mechanical cascade refrigeration system (air-cooled condenser) Refrigerator Hermetically sealed compressor Refrigerator capacity 400W [Unit 1: 400W 1, unit 2: 400kW 1] Expansion mechanism Capillary tube system Refrigerant R404A R23, R404A Cooler Plate fi n cooler Air circulator Propeller fan Fittings Cable port ID 25mm (2), specimen power supply control terminal, temperature recorder terminal, external alarm terminal, external output terminal, power cable Capacity L 22.5 64 Chamber total load resistance kg 20 Inside dimensions mm (inch) W300H300D250 (W11.81H11.81D9.84) W400H400D400 (W15.75H15.75D15.75) Outside dimensions mm (inch) W440H560D695/722 (W17.32H24.8D27.36/28.43) W440H620D785/812 (W17.32H24.41D30.91/31.97) W540H660D920/930 (W21.26H25.98D36.22/36.61) Weight kg 78 (73 for 100V type) 100 123 Allowable ambient conditions 5 to 35 (41 to 95 Utility requirements Power supply *4 100V AC 150/60Hz 11.0 A 15.0 A 18.0 A 115V AC 160Hz 10.5 A 14.5 A 200V AC 150/60Hz 10.5 A 220V AC 150/60Hz 7.0 A 9.5 A 10.0 A 230V AC 150Hz 6.5 A 9.5 A 10.0 A CE marking Noise level *5 db 55 59 61 Exhaust heat quantity 3500 (836) 4000 (955) 5040 (1204) kj/h (kcal/h) *1 At ambient temperature 23, with no specimen. Lowest attainable temperature performance guaranteed to max. 30. (ambient temp.) *2 Performance shown above conforms to JTM K01-1998 *3 At ambient temperature above 32 (30 for SU-221/241), temperature pull down performances decrease and the difference between each chamber increases. It is recommended to keep ambient temperature to a maximum of 30 (28 for SU-221/241) *4 At ambient temperature 23. For SU-641/661, make sure to check the power capability of your installation beforehand. *5 Measurements are to be taken in an anechoic room at a height of 1.2m from the fl oor and a distance of 1m from the chamber front panel (ISO 1996-1:2003 _ A-weighted sound pressure level) 8

TEMPERATURE & HUMIDITY CONTROL RANGE (SH) Relative Humidity (rh) 100 90 80 60 50 40 30 20 10 0 S - 1 10 20 30 40 50 60 80 90 100 15 Temperature () 85 * At ambient temperature 23 MODEL Temperature range2: 20 to 150 4: 40 to 150 6: 60 to 150 Capacity 2: 22.5L 6: 64.0L H: Temperature & humidity chamber U: Temperature chamber 95rh SAFETY DEVICES Leakage breaker Thermal fuse Boil dry protector (SH only) Control circuit short-circuit protective fuse Overheat and overcool protector Air circulator temperature switch Specimen power supply control terminals Refrigerator overload relay Refrigerator high pressure switch Test area door switch Upper and lower temperature (& humidity) limit alarms (Built-into temperature [humidity] controller) Burn-out detection circuit (Built-into temperature [humidity] controller) Watchdog timer (Built-into temperature [humidity] controller) Refrigerator automatic delay circuit (Built-into temperature [humidity] controller) ACCESSORIES Shelf 1 Capacity SH/ SU-221, 241, 261: 500g SH/ SU-641, 661: 5kg Max. number of shelves SH/ SU-221, 241, 261 5 (Shelf pitch 35mm) SH/ SU-641, 661 5 (Shelf pitch 50mm) Connector 2P for connecting terminal for temp. & humid. recorder SH:2/ SU:1 6P for connecting signal terminal 1 Cable port plug 2 Cartridge fuse 3A 1 Socket adapter (100V, 115V on 20L type only) 1 Wet-bulb wicks (box of 24; SH only) 1 Humidifying tray drain hose 2m 1 (SH only) Water tank drain hose 0.3m 1 (SH only) User's manual 1 DANGER Do not use specimens which are explosive or inflammable, or which contain such substances. To do so could be hazardous, as this may lead to fire or explosion. Do not place corrosive materials in the chamber. If corrosive substances or liquid is used, the life of the unit may be significantly shortened specifically because of the corrosion of stainless steel, resin and silicone materials. Do not place life forms or substances that exceed allowable heat generation. 9 CAUTION Be sure to read the user's manual before operation.

DIMENSIONS unitmm (inch) SH-221241 SH-261 1 (6.7) 1 (6.7) 300 (11.8) 250 (9.8) 300 (11.8) 250 (9.8) 440 (17.3) 695 (27.4) 27 (1.1) 510 (20.0) 630 (24.8) 90 (3.5) 440 (17.3) 175 (6.9) 250 (9.8) 18 (0.7) 300 (11.8) 440 (17.3) 150 (5.9) 510 (20.0) 690 (27.2) SH-641661 400 (15.7) 400 (15.7) 540 (21.3) 920 (36.2) 10 (0.4) 205 (8.1) 400 (15.7) 18 (0.7) 30 30 30 785 (30.9) 175 (6.9) 300 (11.8) 250 (9.8) 18 (0.7) 27 (1.1) 1 (6.7) 400 (15.7) 90 (3.5) 610 (24.0) 730 (28.7) 540 (21.3) 440 (17.3) 10

DIMENSIONS unitmm (inch) SU-221241 SU-261 300 (11.8) 250 (9.8) 300 (11.8) 250 (9.8) 440 (17.3) 695 (25.7) 27 (1.1) 30 530 (20.8) 560 (22.0) 250 (9.8) 30 440 (17.3) 18 (0.7) 300 (11.8) 18 (0.7) 440 (17.3) 785 (30.9) 27(1.1) SU-641661 400 (15.7) 400 (15.7) 30 590 (23.2) 620 (24.4) 436.5 (17.1) 250 (9.8) 300 (11.8) 540 (21.2) 920 (36.2) 10 (0.4) 630 (24.8) 660 (25.9) 536.5 (21.1) 400 (15.7) 400 (15.7) 18 (0.7) 11

OPTIONS Paperless recorder-portable type Records temperature of each section such as the temperature inside the chamber. [Temperature type] Temperature range: 100 to 200 Number of inputs (Initial setting): Temperature 1 (5 more channels can be turned ON) Data saving cycle: 5 sec Portable type External recording media: CF memory card (256MB) USB port Language support: ENG, JPN [Temperature and humidity type] Temperature range: 50 to 150 100 to 150 Humidity range: 0 to 100%rh Number of inputs (Initial setting): Temperature 1 / Humidity 1 (4 more channels can be turned ON) Data saving cycle: 5 sec Portable type External recording media: CF memory cord (256MB) USB port Language support: ENG, JPN Paperless recorder Portable type Temperature recorder (Portable type) SRJ25 100 to 200 100mm Portable type 6 dots Thermocouple type T (Copper/ Copper-Nickel) Free power supply (100V AC to 240V AC) Temperature & humidity recorder (Portable type) SRJ14 100 to 150/ 0 to 100%rh (for SH) SRJ12 50 to 150/ 0 to 100%rh (for SH) 100mm Portable type 6 dots Temperature: 5 dots Thermocouple type T (Copper/ Copper-Nickel) Humidity: 1 dot DC1 to 5V Free power supply (100V AC to 240V AC) Wet-bulb temperature detecting terminal For the test area wet-bulb temperature detection. A thermocouple type T (Copper/Copper-Nickel) or of equivalent thermoelectric capacity is used. Connector included. * Not available for SU. Viewing window SH/SU-221, 241, 261 W215H215mm SH/SU-641, 661 W215H315mm When equipped with a viewing window, chamber performance are as follow: Temperature uniformity : 1.0 (20 to 100) 1.5 (100.1 to 150) Humidity uniformity : 5.0rh heat up rate: Std rate 10 min. (or less) pull down rate: Std rate 10 min. (or less) (20 to 35) Std rate +30 min. (or less) (20 to 60) Inner door W215H215mm Glass door provided inside the chamber, to observe the conditions of the specimens. * A wiper is included for SH models. * This option is not compatible with a viewing window or right-opening door. * Used for observation of the specimens inside the chamber. Thermocouple Attached to specimens to measure specimen temperature. Thermocouple type T without ball (Copper / Copper-Nickel) * Same as accessory items SU model 12

OPTIONS Right-opening door Door can be changed for a reverse one (hinges on the right, handle on the left) * This option is not compatible with inner glass door option. Additional cable port Provided in addition / replacement of the standard cable ports. 25, 50 or 100 mm diameter, or flat cable port * Each cable port is equipped with a silicone sponge rubber plug. * Basic specification of the chamber may not be met when equipped with a cable port. Auxiliary water tank circuit (SH) Used to automatically refill the standard tank with the auxiliary water tank. Pure water supply (electrical conductivity 0.1 to 10μS/cm) Water supply pressure: 4.9 to 19.6KPa (Gauge) Auxiliary water tank (SH) Used to refill the standard tank. Tray for auxiliary tank (SH) Prevents water leakage during standard tank refill process. Shelf Equivalent to standard accessory: SH/SU-221, 241, 261 Effective size W200D150 mm Load resistance 500gr. SH/SU-641, 661 Effective size W300D300 mm Load resistance 5kg. Stand Enhances the mobility of the chamber, and facilitates load/ unload of specimens. L stand can fit under the H stand to save space. * Be sure to secure the stand to the floor with the provided anchor bolts. L stand SH/SU-221, 241: W440H450D750mm (25kg) SH/SU-261: W440H390D750mm (21.5kg) SH/SU-641, 661: W540H350D860mm (28kg) H stand SH/SU-221, 241, 261: W630H1140D815mm (36kg) SH/SU-641, 661: W730H1140D925mm (40kg) Specimen basket Equivalent to standard accessory. Material: Stainless steel (5 mesh) L stand 25mm diameter type flat type Cable port rubber plug Prevents air leakage from the cable port. Two chambers stacked (L and H stands) 13

OPTIONS Interface GPIB RS-232C * Select one, instead of standard RS-485 Some photographs listed in this catalog contain Japanese display. This product can be customized for your needs. For further information, please contact us. 14

http://www.espec.co.jp/english Head Office 3-5-6, Tenjinbashi, Kita-ku, Osaka 530-8550, Japan Tel : 81-6-6358-4741 Fax : 81-6-6358-5500 ESPEC NORTH AMERICA, INC. Tel : 1-616-896-6100 Fax : 1-616-896-6150 ESPEC EUROPE GmbH Tel : 49-89-1893-9630 Fax : 49-89-1893-96379 ESPEC (CHINA) LIMITED Tel : 852-2620-0830 Fax : 852-2620-0788 ESPEC ENVIRONMENTAL EQUIPMENT (SHANGHAI) CO., LTD. Head Office Tel : 86-21-51036677 Fax : 86-21-63372237 BEIJING Branch Tel : 86-10-646225 Fax : 86-10-646236 TIANJIN Branch Tel : 86-22-26210366 Fax : 86-22-26282186 GUANGZHOU Branch Tel : 86-20-83317826 Fax : 86-20-83317825 SHENZHEN Branch Tel : 86-755-83674422 Fax : 86-755-83674228 SUZHOU Branch Tel : 86-512-68028890 Fax : 86-512-68028860 ESPEC TEST TECHNOLOGY (SHANGHAI) CO., LTD. Tel : 86-21-68798008 Fax : 86-21-68798088 ESPEC SOUTH EAST ASIA SDN.BHD. Tel : 60-3-8945-1377 Fax : 60-3-8945-1287 Quality Management System Assessed and Registered ESPEC CORP. has been assessed by and registered in the Quality Management System based on the International Standard ISO 9001:2008 (JIS Q 9001:2008) through the Japanese Standards Association (JSA). Registration : ESPEC CORP. (Overseas subsidiaries not included) Environmental Management System Assessed and Registered ESPEC CORP. Specifications are subject to change without notice due to design improvements. W3B23C02 (The contents of this catalog is as of March, 2011.) Corporate names and trade names mentioned in this catalog are trademarks or registered trademarks.