Rotary Oil Burner Construction

Similar documents
Module 5: Combustion Technology. Lecture 38: Combustion Burners

High Performance Diesel Fueled Cabin Heater. Abstract

Pumps SELECTION OF A PUMP

B.Tech. First Semester Examination Basics of Mechanical Engineering (ME-101F)

ROTARY DRYER CONSTRUCTION

PIPING SYSTEM EQUIPMENTS

FAS Fresh Air Supply Units

COPYRIGHTED MATERIAL. Chapter 1. Oil Burners

SECTION HEATING BOILERS

(12) United States Patent (10) Patent No.: US 6,647,932 B1

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

DESCRIPTION, CAPACITIES, SPECIFICATIONS, APPLICATIONS

Multistage Centrifugal Pumps with Shaft Sealing Type HZ / HZA / HZAR

ASSSIGNMENT 3. Textbook Assignment: Boilers, chapter 4, pages 4-1 through 4-15, and Steam Turbines, chapter 5, pages 5-1 through 5-1.

NOZZLE MIX COMBINATION BURNER NMC200 SERIES

ASE 7 - HVAC. Module 2 AC Compressors

Heat Exchanger. The purpose may be either to remove heat from a fluid or to add heat to a fluid.

ProMinent ProMus Hydraulic Diaphragm Metering Pumps

DS series STERLING PUMPS. Industrial End Suction Pumps ISO/DP

KRAL Screw Pumps. L Series.

Direct Fired Heater Model AD Specification

GA Gas Unit Heater Assemblies Technical Guide

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

Boiler Draft Equipment

Installation & Service Instructions for Jackson & Church Flexaire Packaged Furnaces SDF-125 thru SDF-400 Gas Firing

International Reactor Bulletin 1100 Corporation. Standard and Custom Reactors for the Chemical Process Industries

Product Information. Model: HG, HL, HLG Burner Sizes: 10, 13, 15, 17, 20, 21, 25 GENERAL DESCRIPTION U.L. STANDARD EQUIPMENT

COOLING SYSTEM 1. Section V CONTENTS DATA AND SPECIFICATIONS. Page. Fluid Fan Drive (Silent Flite) 3. Water Pump 4. Radiator 5

PUMPS FOR LIVESTOCK WATERING SYSTEMS. This Factsheet outlines the design and operation of pumps that are suited for livestock watering systems.

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

CENTRIFUGAL PUMPS. STATE the purposes of the following centrifugal pump components:

LN series STERLING PUMPS. Horizontal Split Case Pumps. Double Volute. Single Stage.

Line Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas

Design and Construction Standards SECTION PLUMBING EQUIPMENT

BURNERS/ FLARES. VAREC BIOGAS 244W Series WASTE GAS BURNER & IGNITION SYSTEM

PhiloWilke Partnership Addendum No. 2 A/E Project No April 2016

TGIF-1. Indirect Fired Heating Systems. Technical Guide for: IF Indoor Installations. IFW Outdoor Installations. Applied Air. Keeps You.

PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS

Air Conditioning Components

Homework Chapter2. Homework Chapter3

Rail car driven by steam

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

Fan Motor. user manual INSTALLATION - OPERATION - MAINTENANCE

Module 7: Air Supply System

Copy Right By: Thomas T.S. Wan

GIRTON CABINET WASHER MODEL 794A

Heating Systems. Brooders, Space Heaters and QuadRadiant Heaters

PREVIEW COPY. Compressors. Table of Contents. Introduction to Compressors...3. Lesson Two Reciprocating Compressors...21

Heating, Air Conditioning, Ventilation. Отопление-Кондиционеры-Вентиляция. MTM 8-30 kw UNIVERSAL OIL HEATER OPERATING MANUAL

V-Series. Oil Lubricated Rotary Vane Vacuum Pumps

Burner Comparisons. Typical Competitor s Burner

380 Series Multi-Stage Centrifugal Pumps

PVE SERIES POWER VENTER SYSTEM MANUAL

SECTION PLUMBING EQUIPMENT

APS Chiller Seminar. Don Brandt, CEM-AEE, BEAP-ASHRAE ASHRAE and IEEE Life Member 3/16/2017

Steam Generator (Boiler) & Steam Turbine. Steam Generator (Boiler) ME 268. Model Lab

batch Chargers I N N o V a t I o N e N g I N e e r e d I N g e r M a N Y

MCV - MCH - MCHZ Multistage pumps

VENTLESS DOOR-TYPE DISHWASHER

IV SEMESTER DIPLOMA EXAMINATION, JANUARY-2013 THERMODYNAMICS

NMG NOZZLE MIX GAS BURNERS

POWER VENTER SYSTEM. Model: PVO-300, PVO-600

Agitation and Mixing

COOPERATIVE PATENT CLASSIFICATION

Model CB-LE. Packaged Boiler HP. Operation, Service, and Parts Manual /09. and Model CB Ohio Special HP

Vertical In-line Self-Priming liquid ring Centripetal pump TYPE - STP

USER S INFORMATION MANUAL

PGF SERIES 7-1/2 Ton. Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

product Industrial burners Industrial burners sizes 30 to 70 flexible and reliable Information on oil, gas and dual fuel burners

V-Series Oil Lubricated Rotary Vane

HOW TO SELECT AN INDIRECT THERMAL TECHNOLOGY FOR INDUSTRIAL MATERIALS PROCESSING

SHP High Pressure Radiant Gas Brooder Series

INSTRUCTION MANUAL FOR OIL BURNER MODELS

The pump. A pump is a device that moves fluids (liquids or gases), or sometimes slurries, by mechanical action.

AFUE 95% Heating Input 50,000 to 200,000 Btuh

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

FAIRBANKS NIJHUIS SOLIDS HANDLING PUMPS.

POWER VENTER. Model: PVE Series

MULTIPLEX SELF RECUPERATIVE gas burner

PDHonline Course M140 (3 PDH) Pumps. Instructor: Lawrence J. Marchetti, P.E. PDH Online PDH Center

Solutions to Pollution

Oil burners fuel unit with solenoid valve

DIFFERENT SPRAYERS AT A GLANCE

MAXIMUM SERIES. Maximum Series portable chillers can be used on a variety of process applications that require 20 F to 70 F chilled water.

MCF 500 CENTRIFUGAL FAN FOR AIR, FOR BIOGAS, LANDFILL AND NATURAL GAS

SKYPAK II, 3 Ton Series, gives you a

AM SELECT DISHWASHER STANDARD FEATURES MODEL OPTIONS AT EXTRA COST ACCESSORIES VOLTAGE. Item # Quantity C.S.I. Section AM15

Downtime Instructions

21 20 LITER GAS FRYER FFA3200 INSTALLATION AND SERVICING.

"NP" & "RG" AIRFLO. In-duct firing line burner

Fans: Features and Analysis

MECHANICAL ENGINEERING ME.2017 FUNDAMENTAL OF REFRIGERATION AND AIR CONDITIONING. Sample Questions and Answers

INSTRUCTION MANUAL FOR OIL BURNER MODELS

Zeeco, Inc. Doc. No Tulsa, Ok Cover Page GLSF-14 Free-Jet and RWSF-4 Radiant Wall Burners. Range Fuels Soperton Plant, LLC

cooling tower downtime instructions

HORIZONTAL FIRE TUBE BOILERS Piping (HVAC) Pumping Equipment (HVAC).

RL/1 SERIES. One Stage Light Oil Burners FIRING RATES LIGHT OIL RL 34/1 MZ kw

INSTRUCTION MANUAL FOR OIL BURNER MODELS

following distribution into ampoules led to the development of the freezing

Roots TM Blowers, Compressors & Controls

Transcription:

Rotary Oil Burner Construction 133 CHAPTER 17 Rotary Oil Burner Construction The construction of this type burner whose basic principles and essential elements were presented in the preceding chapter are here given by showing various details of both the nozzleand cup forms as actually made. Nozzle Type Burner Construction.-This type of rotary burner is sometimes called a wall flame burner. The burner employs a vertical motor that rotates an oil nozzle or distributor and fan, the oil being projected radially by centrifugal force. In place of motor drive, some designs have a propeller energized by a blast of air from the draught fan. In either type air and oil are propelled radially from the center of the fire box. The mixture of air and oil is thrown outward against a target of refractory material which gets red hot and vaporizes the fuel. Rotary Cup Burner Construction.-An example of cup burner construction is here given in fig. 1 with names of parts in text under the cut. In construction upon a hollow alloy steel shaft, there are assembled the rotor, annular ball bearings, pump driving worm gear, fan and atomizing cup of a type to give flame shape desired to fit the boiler combustion chamber.

134 Rotary Oil Burner Construction Lubrication is constant from oil reservoir below bearings an worm. A variety of interchangeable cups, as shown in figs. 5 to 11, available for the various burner sizes. Cups are long to allow cent Rotary Oil Burner Construction 135 Fig. 12 shows the semi-automatic type burner swung open on hinge also showing mounting plate with bolts to boiler front PETRO MODEL W Genoral Sectional View (Manual Type) - Fics. 2 to 11 Details (Model 'N) shaft assembly, ball bearings and rotary cups. 44 Fic. i Sectional view of rotary cup oil burner model W, manual type. 1. Oil metei valve (manual type shown to simplify drawing); 2, stationary oil tube; 3, oil distribui head; 4, rotary distribution cup; S, motor cooling induced air passages; 6, primary control; 7, air fan; 8, primary air pass; 9, turbulator air nozzle; 10, induced air to burner front plate and sleeve; 11, electric motor armature; 12, field core; 13, fieldwi ings; 14, shaft; ball bearings; 16, worm pump drive; 17, worm gear; 18, lubricating reservoir; 19, motor wiring junction box; 20, sleeve. fugal action to create a thin film of oil for uniform distribution the thin cup rim where primary air and oil meet. mounting plate ic. 12 Mode W semi-automatic burner mounted on hinge showing which bolts to boiler front plate providing heavy shield which protects nozzle assembly when in firing position.

Rotary Oil Burner Construction 136A Preferred Utilities Model BR Combination Oil-Gas Burner. This is a horizontal rotary burner of the nozzle mix type. It offers automatic change from one fuel to the other, and is designed for light or heavy oils, and for natural, mixed or L.P. gas. Regulated gas pressure can be as low as 3 ins, on 1050. B.t.u. gas of.65 specific gravity. Slightly higher pressure is required on lower B.t.u. xos. 13 and 14 Two views of turbulator for model W, burner. ELEC 0 P11 OIL FU TUBE ri 15--Diagran-t.of combined electric steam system for pre-heating heavy fuel oil. Fm. 15a. Preferred Utilities Model BR combination oil-gas burner nozzle mix type.

136B F Rotary Oil Burner Construction The primary air used to atomize the oil is also used to create turbulance and the mixing of the gas that is discharged from the port around the burner nozzle with the air required for combustion. A special gear drive assembly that provides manual disconnect of the fuel oil pumps on the burner is standard on #6 oil and available for #5 oil. A series of gas jets control the flow of gas from the manifold to the circular gas port surrounding the burner nozzle. These jets are factory sized to meet the requirements of the gas to be burned. A manual throw over switch permits full automatic operation on oil or gas. An automatic switch operated by an outdoor thermostat can be employed to change from one fuel to the other. Rotary Oil Burner Construction 137 Ray Horizontal Rotary Oil Burners. They are built to iie every available fuel oil from light Diesel oil (C.S.G. No. 2) to bunker C (C.S.G. No. 6). Ques. Describe the burner unit construction. Ans. The burner consists of a hollow shaft on which are mounted the rotating units of an electric motor, a fan and a Mpraying cup. 2 4 7 lic. 16. Ray angular vane nozzle. isil, :( Fic.I: Johnson.omhina tionol I and gas burner. The annular gas distributing chamber 1, surrounds the oil burner atomizer 2. Gas enters this annular chamber through rigid and permanent connections in the, fire hole plate and is discharged through the multiple orifices 3, directly across the primary air stream 4, to obtain a combustible mixture. Burner can be swung out of firing position without using a gas swivel, and without disconnecting oil or gas pipe lines. The unit rotates on two ball bearings. A stationary fuel tube within the rotating hollow shaft delivers the fuel oil to the burner cup as in fig. 16. The complete unit is enclosed and the motor is cooled by radiating fins on all but the largest sizes. Ray Angular Vane Nozzle. Primary air is furnished by the burner fan and is forced through the angular vane nozzle in a swirling rotary motion opposite to that imparted to the oil as it leaves the rim of the cup, as in fig. 16. Ques. What is the effect of this arrangement?

138 Rotary Oil Burner Construction Rotary Oil Burner Construction 138A Ans. By this means the primary air and the thin film of oi spun off the rim of the cup at high speed are intimately mixed for efficient combustion. These angular vane nozzles are made in different angulations to shaju the flame to fire-box requirements. Ray Dual Pump and Reservoir. As shown in fig. 17 the are two constant speed gear type PUmPS submerged in a reservo' 4 404 Preferred Utilities Belt Driven Horizontal Rotary Jlurner. These burners are made in capacities of 12 to 175 gallons. The burner has such features as: Dual oil feed pump; "Voluvalve" fuel regulation; electric to gas ignition; air oil control and high speed belt drive, as here described. A \. TARA Olt I 7. Ray dual pump and reservoir. Ques. Describe the operation of these pumps. Ans. The primary pump draws oil from the storage tan into the reservoir containing a gallon or more of oil and tli secondary pump delivers a constant volume of oil to a speci automatic viscosity valve. 1' The viscosity valve supplies a constant controlled metered volume oil which is unaffected by changes in the viscosity of the oil. The vi cosity valve maintains a uniform oil feeding rate which can be varic by a special regulating valve to meet changing load adjustments. H FIG. 18. Preferred Utilities standard Volu-valve in reservoir. 1, voluvalves; 2, pressure gauge; 3, temperature gauge; 4, pump; 5, equalizing valve; 6, electric heater; 7, reservoir.

138B Rotary Oil Burner Construction Rotary Oil Burner Construction 138C Since the discharge pump is always submerged, it maintains a constani discharge volume. An electric heater, also submerged, keeps the oil in th reservoir and cored passages in the burner at the proper temperature i1. all times for dependable starting. Below the burner and mounted to it by flange is an oil well containhi l l a line voltage, thermostatically controlled, electric heater. The heater warms the oil consumed by the burner until the external oil supply and oil heating system come into operation. This heater in conjunction with the one in the reservoir keeps all oil in the burner at the proper startin temperature. Discharge flows through two proportioning valves, one admitting oil to the burner, the other to a return line. Both valves are interconnected through an outside lever so that the ports of one open as the ports of the other close, in exact ratio to the turn of the lever. A thermometer, pressure gauge and pressure relief valve are built into the "Voluvalve" reservoir. Electric to Gas Ignition. An electric to gas ignition pilot with overhead mounting provides a gas enveloped oil spray which speeds up oil ignition and minimizes puff-back starting. An ignition wire is conducted to the igniter along with a gas line through a common flexible tube bracketed on the front plate. There is no possibility of radio interference. Operation is from a remotely located transformer. Gas is introduced from a remotely located gas valve which opens with the motor circuit. The dependability of this arrangement makes only one large igniter necessary. High Speed Belt Drive. The employment of belt drive permits an extra large hollow shaft which provides room for a large diameter fuel tube for oil delivery to the cup. The cup is driven at 4,700 r.p.m. which gives better spraying especially with the new catalytic residual oils. The low intake line intake and high return line outlet act primarily to minimize the amount of external piping on the burner, thus permitting oil in the burner assembly to be kept heated during shut down periods. FIG. 19. Diagram of optional equalizing valve used in conjunction with standard valve. A thermostat in the control circuit prevents starting and contin running until the proper oil temperature is obtained. "Voluvalve" Fuel Regulation. This device is placed at, the top of the reservoir and consists of a fuel volume delivery control valve which is designed in conformity with Poiseuil1e' Law. It meters a predetermined quantity of residual oils regardless of changes in temperature, pressure or viscosity. Burning Heavy Oils. Although the heavy oils (No. 5 and 6) contain more B.t.u.'s per gallon than the lighter oils, and generally cost less, their use has been hampered by their unreliable performance in burners not designed to burn these heavy oils. The main problem has been to maintain a steady, even flow of oil to the burner head. Heavy oils are subject to wide fluctuations in viscosity. When hot they may flow as readily as stove oil, and when cold may approach the sluggishness of tar. The viscosity factor is not constant. Heavy oils are residue oils the left overs after the refining process is completed. Oils obtained at different

138D Rotary Oil Burner Construction times from the same source may contain varying amounts of the viscoul elements. It is therefore difficult to control viscosity by means of tel perature control, even if it were practical to maintain oil temperaturn within a very narrow range. Even with thermostatically controlled oil heaters, fluctuations of 10 degress or more may occur under normal boiler room conditions a temperature variation sufficient to materially affect the viscosity of heavy oil. Ques. Mention an important requirement and why imj portant? I Rotary Oil Burner Construction 138E Ans. Accurate metering of oil to the burner head is very important, as it is obvious that a steady, even flame under perfect control can be maintained only by a steady flow of oil. Ques. Describe the conventional method of oil control. r END OF PISTONS CYLINDER- PISTONS- \ SPRING HELD BLOCK AGAINST PLATE (Rotating) \ ' OIL DISCHARGE SIDE I AKE SIDE L ANGLE OF PLATE CONTROLS LENGTH OF PISTON STROKE AS PISTON ASSEMBLY ROTATES, METERING OIL VOLUME Fig.?Q. Ray rotary oil burner for heavy fuel direct drive type AR-134 illustrating dual ignition. lie. 21. Iron Fireman oil volumeter. Ans. It comprises an adjustable valve or port, often with an automatic device for changing the opening to compensate for changes in viscosity. Since the viscosity factor is not controllable, it is held that the only reliable means of precision control of oil was to meter it by volume. Ques. What has been done to secure this precision control?

s ro u e s t 138F Rotary Oil Burner Construction Ans. Various metering devices have been developed by ti different manufacturers as here described and known by ii dustrial trade names. Iron Fireman "Volumeter." In this feeding device, oil is metered to the burner head not by changing the size of the hole through which it flows or by varying the pressure, but by multiple piston feeding. Completely submerged in the oil reservoir, a multi-piston cylinder block revolves, pulling oil into each cylinder in turn, and a half-revolution later ejecting it into the feed line. The multiple cylinders assure a steady, controllable flow of oil. There are no adjustable valves or ports to open or close. The oil feeds smoothly automatically. The oil volumeter is submerged in the oil reservoir, constantly operating under an ample head of oil. The construction is shown in figs. 21 and 22. o sp th Fic. 22. Sectional view of Iron Fireman volumeter. The diagramatic view of the reservoir shows circulation gear pump and oil volumeter mechanism. Arrows indic direction of oil flow in system that provides for oil circulation through indirect steam hot water oil heater. s