ABSOLUTE Temperature Control System

Similar documents
Mark 25 Ultrapure Water Conductivity Analyzer

Liquid Helium Level Instruments

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...

OG5000 Ozone Generator Model OG5000B-A. User Manual

Oxygen (O2) Single-Point Gas Detection System

Centro-Matic Automated Lubrication Systems System Controls

Model Super TJE. Ultra Precision Pressure Transducer DESCRIPTION FEATURES

PARAGON Commercial Refrigeration Controls

OPERATION MANUAL. THE JENCO MODEL 6230 MICROCOMPUTER BASED ph/mv/temp PORTABLE METER JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISION INSTRUMENTS

Duct and Rough Service Carbon Monoxide Sensor

JENCO INSTRUMENTS, INC. JENCO ELECTRONICS, LTD ARJONS DR., SUITE C P.O. BOX LINKOU-117

Analog Input Module IC670ALG630

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

573 Dew Point Mirror. Industrial Chilled Mirror Hygrometer. Typical applications:

MANUAL. OEM (Unit) OZONE GENERATOR (100VA, 200VA and 300VA) INDEX

Datasheet: K-22 LO Sensor

ECW-GF, ECW-GF-DP DIGITAL ELECTRONIC CONTROLLERS AND REMOTE DISPLAY PANEL PRODUCT OVERVIEW

PUV, PIR and PFO Series BROCHURE

tcm100, tcm101 Series Temperature Control Modules and PTS100, PTS100/3 Pipe Temperature Sensors Operations Manual

Analog Room Pressure Monitor RPC Series

RH & T Sensors & Humidistats. RH-DT Duct Mount RH & T Sensors. Description

RTD TEMPERATURE SENSING SYSTEM

T7984 A,B,C Electronic Modulating Control Thermostats

VAV Thermostat Controller Specification and Installation Instructions. Model TRO24T4XYZ1

Modules and Accessories. Table of Contents. Theta Optical Tensiometer. I - Mandatory modules 2. II - Accessories 4

THERMAL MANAGEMENT SOLUTIONS

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

MODEL A5-2 SOLVENT & WATER RECOVERY SYSTEMS (EXPLOSION PROOF UNITS)

ELECTRONIC FLAME SUPERVISION MULTI-BURNER

INSTRUCTION MANUAL Portable Refrigerator Units MODEL 15-LITER Including the Standard Battery Backup System (BBS)

Rooftop Thermostat Controller Specification and Installation Instructions. Model TRT2422

Model gffoz Process Ozone Sensor (In-Line)

0 C to 50 C ( 32 F to 122 F ) 0% to 95% R.H. non-condensing. 30 to 95% R.H. Dry contact across terminal BI1, BI2 & UI3 to Scom

Model A-5. Low Range Wet/Wet Differential Pressure Transducer DESCRIPTION FEATURES

Combustible Gas Detection and Control System

OKM 801INFANT INCUBATOR

Durafet II and Meredian II Combination ph/orp Electrodes for Honeywell 7777 Mountings Series 7777 Specifications

A New Standard of Excellence

THERMAL MANAGEMENT SOLUTIONS

Series 9000 Total Hydrocarbon Analyzer

The LC-100 s valved manifold controls the flow of air and allows the LC-100 to accurately monitor liquid levels with a minimal air usage.

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

UC INSTRUMENTS GM8036 LASER SWEEP OPTICAL SPECTRUM ANALYZER (1525 ~ 1610 nm) Technical Specifications v1.01 March, 2011

ProRadiant Controls, Valves and Actuators

F-1100 Series Single Turbine Meters Suitable for pipe sizes 1 ¼ and larger.

MODEL A18 SOLVENT RECOVERY SYSTEMS (EXPLOSION PROOF UNITS)

Heated and Refrigerated Incubators

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies.

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies.

Series 3300 TELEDYNE ANALYTICAL INSTRUMENTS. The 3300 series of low cost, microprocessorbased

Read and save these instructions. VAPOR-LOGIC 3. Microprocessor-based humidifier control system Installation and operation manual

Thermo Scientific Round Top Hotplate Stirrers. Make safety and accuracy part of your routine

DFM. flow pressure temperature MULTI PARAMETER DIGITAL MASS FLOW METERS. Totalizer. Interface

LDRA6 ARCHITECT AND ENGINEER SPECIFICATIONS. RLE TECHNOLOGIES Rev

DIMENS. MIN TYPICAL MAX A 71.0 (2.795) 71.0 (2.795) 71.8 (2.826) B 29.0 (1.141) 29.0 (1.141) 29.8 (1.173)

Isotemp. Improve the productivity of your laboratory with accurate, efficient temperature control products from Fisher Scientific.

Modules and Accessories

Automatic Isokinetic Sampler ST5

Accuracy by Design Products for the HVAC Professional

MODEL 4100-LEV. Level Monitor. User Manual

Hotplates, Magnetic Stirrers and Stirring Hotplates

4000TOC Sensor. Continuous On-Line Measurement Total Organic Carbon Monitoring. THORNTON Leading Pure Water Analytics

Sensor Interface Module Installation/Operation Instructions

Package Contents. Dry Block Heater Power Cord Instruction manual Warranty Card. Serial Number: Date of Purchase: Supplier: Table of Contents

0-10 V Wall & Duct Humidistat Installation Instructions

Sensors in Ventilators

Two-Channel Gas Controller

MEMS Accelerometer ICs. AMR Magnetic Sensor ICs. Gas Flow Modules. Differential Pressure Sensors. Tilt Modules. Current Sensors

LD1000 ARCHITECT AND ENGINEER SPECIFICATIONS. RLE TECHNOLOGIES Rev

DT968C C.T. BATH CONTROLLER

Line Isolation Monitor (LIM) LIM2000plus

Analyze IT Zirconia Oxygen Analyzer for Small Boiler Applications

HP727S. Single speed swimming pool heat pump controller Operation manual TABLE OF CONTENTS

Eclipse Self-Check UV Scanner

MODEL QTS-1800 SERIES WALL MOUNT DIGITAL AND ANALOG TRANSMITTER/SENSOR

Oxygen Analyzer Manual

DGC-500 DIGITAL GENSET CONTROLLER

Sierra Model 951 Digital Flo-Box. Instruction Manual Part Number IM-951 Revision A 09-05

XWA11V. Walk-In Temp / Door /Alarm / Light Module

KIT IOM

Installation Instructions for the Honeywell Force Sensors FSA Series Compensated/Amplified

ELECTRONIC HUMIDISTAT: H270

Carbon Monoxide (CO) Gas Detectors with (0)2-10 Vdc or (0)4-20 ma Output

ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL

RANGE. 2600/1950 Watts. 240/208 Volts BAKE ELEMENT /2100 Watts. 240/208 Volts. 90 degree BAKE ELEMENT Watts.

ESSEX ENGINEERING CORPORATION

Lynergy Comfort Control SCR Electric Heater Application Guide

Precise Temperature Control; Compact Footprint

PT101. General. Full Stroke Range Options. Potentiometer Cycle Life Maximum Retraction Acceleration. Electrical

300/400 UNITS - MODULAR CONFIGURATION

Submittal. Date: September 04, Customer P.O. Number: Customer Project Number:

Using the Model 1500 Portable Chilled Mirror Hygrometer

ACS-30 MULTIPOINT COMMERCIAL HEAT-TRACING SYSTEM PRODUCT OVERVIEW. ACS-30 System

Refrigerated Incubators / Environmental Testing Chambers

ELECTRONIC HUMIDISTAT: H200

Black Body Calibration Source User Manual

Heidolph Vacuum System. Heidolph Vacuum System. Vacuum pumps. Vacuum accessories. ROTAVAC valve control. VAC control automatic. ROTAVAC vario control

TRUERH Series HE-67xx Humidity Element with Temperature Sensor

SLATE. UV Ampli-Check Flame Amplifier INSTALLATION INSTRUCTIONS R8001S1071

Transcription:

Temperature Control System DESCRIPTION The ABSOLUTETM Temperature Control System provides accurate and stable temperature control of liquid source chemicals. Five different models provide temperature control through the range of 10-90 C, with an accuracy of ± 0.2 C. FEATURES AND BENEFITS Modular design for easy installation Microprocessor-based control circuitry for accurate and stable temperature control Electronic and visual (sight glass) level sense (for monitoring chemical levels) Removable source cup permits safe container installation from the front of the unit Full range of safety interlocks DDC interface for remote control and monitoring Holds 1500cc quartz or 1.2 liter stainless steel containers Stainless steel versions incorporate level sense and integrated lid heater Trans-LC version eliminates all spark sources and reduces over temperature cutout interlock APPLICATIONS Temperature control for CVD source chemicals (i.e. TEOS, ZTOMCATS, LTO-410, TMB,TMPI) Temperature control for diffusion and oxide passivation source chemicals (i.e. Trans-LC, TCA, POCl3, and PBr3 and BBr3) RELATED PRODUCTS Delivery Containers 1500cc Quartz Breakseal Containers 1.2 liter Stainless Steel Containers Delivery Equipment Serves as temperature controller for the V MDOT Delivery System Refill Equipment Transfill II Automated Chemical Refill System UltraFillTM Automated Chemical Refill System ATCS with 1500cc patented breakseal quartz bubbler.

ABSOLUTE SYSTEM SPECIFICATIONS PERFORMANCE Temperature Control: Standard Temperature Model: 10 C* to 60 C High Temperature Model: 40 C to 90 C Trans-LC Model: 10 C to 22 C LIQUID LEVEL SENSE * Minimum cooling capability is 15 C below ambient temperature. ** Add a minimum of 78mm (3in) to depth measurements for cable connection clearance. *** Overall height = 62.5mm (2.5in) + source height. **** Not including weight of source and chemical. Temp Accuracy: ± 0.2 C of setpoint Temp Stability: ± 0.1 C Readout Resolution: 0.1 Temp Cutout (std): 70 C Temp Cutout (Trans-LC): 50 C Temp Cutout (high temp): 110 C Quartz Breakseal Container: Discrete level sensors at 100%, 50%, 25% and 15%. Backlit sight glass for visual inspection of liquid level. Stainless Steel Container: Discrete level sensors for indications at 100%, 75% and 15%. S Liquid Level Alarm: Alarm activated when liquid level reaches 15% full. Temperature Alarm: Alarm is activated when the sensed temperature is not within ± 2 C of the temperature setpoint. (± 5 C for Trans-LC unit) Alarm Indicators: All alarm conditions generate an audio alarm, flashing LED display with alarm condition, and an alarm output through the DDC interface. (The audio alarm can be silenced for 30 minute intervals.) DIMENSIONS ABSOLUTE Electronics Module: ABSOLUTE Base Unit Height: 233.7mm (9.20 in) Height: 233.7mm (9.20 in) Width: 63.5mm (2.50 in) Width: 209.6mm (8.25 in) Depth**: 260.4mm (10.25 in) Depth**: 262.9mm (10.35 in) Source elevation***: 62.5mm (2.5 in) WEIGHT ABSOLUTE Base Unit: 6.7kg**** (14.9 lbs) ABSOLUTE Electronics Module: 4.8kg (10.5 lbs) MOUNTING ABSOLUTE must be mounted on a level, low vibration surface. ABSOLUTE base unit should be secured to mounting surface to prevent it from sliding when removing and installing the source cup. ABSOLUTE electronics module can be remoted up to 4.84 meters (16 feet) away from the base unit. POWER REQUIREMENTS 90-154VAC 50/60 Hz 275VA max 180-264VAC 50/60 Hz 275VA max DDC INPUTS Analog Temperature Setpoint

THERMISTOR BRIDGE ERROR GAIN/BALANCE TO DDC VISUAL DISPLAY SOURCE CONTROLLER PRECISION REFERENCE SET POINT DDC MANUAL CONTROL CONTROL HEATER CONTROL LIQUID LEVEL AUDIO VISUAL DISPLAY TO DDC DDC OUTPUTS Analog Temperature Output Analog Level Output Temperature Alarm Liquid Level Alarm Any Alarm CABLE LENGTH DDC Cable 20 Conductor Shielded: 6.10 meters (20ft) 20-conductor shielded ABSOLUTE Interconnect Cable: 456.85mm (18in) standard Cable lengths up to 6.10 meters (20ft) are available upon request. SOURCE CONTAINERS The ABSOLUTE is fully compatible with Schumacher 1500cc quartz and 1.2 liter stainless steel containers. 1.2 Liter stainless steel container:* Standard Configuration (BK1200SS Series) Manual inlet/outlet valves VCR inlet/outlet connectors Level Sense Probe Integral Lid Heater Configuration (BK1200SSV) Pneumatic outlet valve 1/2" male VCR outlet connector Level sense probe TransFill Host Container (BK1200SSR) Designed for automatic refill Pneumatic valves, VCR connectors Continuous and discrete level sense probes included 1500cc Quartz Containers: D-Series Quartz Container (BK3D1) Teflon inlet/outlet valves 1/4" inlet and 3/8" outlet connectors (for teflon tubing) R-Series Quartz Container (BK3R1) Designed for Automatic Refill Pneumatic Teflon Control Valves Continuous and discrete level sense probes included S-Series Quartz Container (BK3S1, BK3S2) SS VCR adaptors * Refer to 1.2 liter Stainless Steel Product Data Sheet for additional information on specific configurations.

PRODUCT PART SOURCE DESCRIPTION NUMBER RANGE CONTAINER ABSOLUTE Std ATCS15 10 to 60 C 1500cc Quartz Temp (BK3D1, BK3S1/2) Quartz ABSOLUTE Std Temp ATCS15-SS 10 to 60 C 1.2 liter SS SS System (BK1200SS Series) ABSOLUTE High Temp ATCS15HT 40 to 90 C 1500cc Quartz Quartz System (BK3D1, BK3S1/2) ABSOLUTE High Temp ATCS15HT-SS 40 to 90 C 1.2 liter SS SS System (BK1200SSV Series) ABSOLUTE Trans-LC ATCS15TLC 10 to 22 C 1500cc Quartz Quartz System (BK3D1) APPLICATION SUPPORT Schumacher maintains an active research program aimed at developing improved source chemicals, processes and delivery equipment. Our technical staff is available to assist you with process problems and safety concerns. For more information please call 1-760-931-9555 or 1-800-545-9242. ORDERING INFORMATION Please contact your Schumacher sales representative for ordering information or call Schumacher at 1-760-931-9555 or 1-800-545-9242.

For More Information If you would like additional information or technical assistance in preparing specific formulations, write or call Air Products and Chemicals, Inc. at the following location. Schumacher 1969 Palomar Oaks Way Carlsbad, CA 92011 Tel: (800) 545-9241 www.airproducts.com/electronics tell me more http://www.airproducts.com/electronics Air Products and Chemicals, Inc., 2001 26-02-106-US-May04