HLR 1000E Technical Specifications

Similar documents
Job Name Control Systems Description Date

Zoning System Design Manual

4. OVERVIEW OF MECHANICAL SYSTEM

Predator Controller Hardware Family

SECTION SEQUENCE OF OPERATION FOR HVAC CONTROLS PART 1 GENERAL

AIR DISTRIBUTION. C. Section Building Automation and Control System Guidelines. D. Section Fire Alarm System & Detection Systems

MiniCore Ventilator (500, 1000) Series Engineering Guide

Siemens Thermostats. RDY2000BN Thermostat

FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design

Warranty Registration

CITY OF DANA POINT. COMMUNITY DEVELOPMENT, BUILDING AND SAFETY Golden Lantern, Suite 209 Dana Point, CA

Troubleshooting the Indoor AHU as a Standard Product

photo by PFC Price Fan Column

FORM EG2 (502) FlexSys Configured Packaged Rooftop Air Conditioning Units

Power and Energy Management Solutions

INSTALLATION MANUAL CONDITIONING ENERGY RECOVERY VENTILATOR (CERV) MODEL CERV-001-PARTA, CERV-001-PARTB

Retrocommissioning Findings Summary: Building X #1 Priority: Major Comfort/Control Problems

Florida Department of Transportation

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) 2016 Q1

COMcheck Software Version Interior Lighting Compliance Certificate

The V in HVAC: Mechanical Ventilation in ENERGY STAR Certified Homes

HVAC DISTRIBUTION and DELIVERY SYSTEMS

DACC Health Sciences Building Air Handler Assessment/Study

CHAPTER 4. HVAC DELIVERY SYSTEMS

Energy Recovery with Cooling and Heating Model ERCH

Complete Ventilation, Heat Recovery and Dehumidification Packaged System by. Maintaining Your Climate for Indoor Pools and Waterparks

B. Use UT Austin specifications and equipment schedule format for HVAC equipment where available.

IAQ Building Education and Assessment Model (I-BEAM)

Topic 2. ME 414/514 HVAC Systems Overview Topic 2. Equipment. Outline

b.) Technical Information:

Introduction. Motor Types

Application Data Part Numbers: 33ZCVVTZC-01, 33ZCBC-01, 33ZCVAVTRM, 33ZCFANTRM

Multi-Zone Wireless Control Training Systems ( )

A. Base Bid: 1. Heating Contractor provide: a. Control sequences for HVAC systems, subsystems, and equipment.

Appendix 13. Categories of Cooling and Heating systems

Product Data. Features/Benefits. AirManager Control. 33AM Comfort System

COMcheck Software Version Mechanical Compliance Certificate

Alpha Aire. Dedicated Outdoor Air System, VAV, Air-Source Heat Pump with Energy Recovery

SmartStruxure Lite Small Building Systems

Technical Assignment 3 11/15/04. Executive Summary

Fan System for Drop Ceilings

DIGI-VAV APPLICATIONS

AIRFLOW MEASUREMENT AND CONTROL PRODUCT CATALOG. Phone: 877-4GNTROL ( ) - Internet: GreenTrol.com. r1f

Model 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions

Outside Air Requirements... SOLVED!

Model 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions

DEHUMIDIFICATION: Ice Arena Application & Product Guide. Design, construct and operate to control indoor humidity in ice rinks

AirCycler g2-k Installation & User s Guide

Checked By: S. Norsworthy Approved By: C. Reimer

DEMAND CONTROLLED VENTILATION WITHOUT WIRES

Energy Recovery Ventilators

Trane Family of Terminal Products

HVAC OUTDOOR AIR VENTILATION STANDARD. ASHRAE Standard ASHRAE Standard

control sequences model QST / EST Series Table 47: QST / EST Analog Electronic Control Strategies Fan Powered Air Terminals

The Creative and Performing Arts High School (CAPA) Pittsburgh, PA 11/11/2002 Andrew Tech Mechanical Option Prof. S. A. Mumma

Civil Engineering Building

INDOOR AIR QUALITY PRODUCT LINE CARD 10.18

INTRODUCTION TO: ASHRAE STANDARD 90.1, HVAC System Requirements for Reducing Energy Consumption in Commercial Buildings

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog

Clearing the Air: Ventilation. RESNET Building Performance Conference San Diego, CA February 17 th, 2015

GLOBAL FINISHING SOLUTIONS

Technical Development Program

Custom Air Handler Solutions Custom Units to Meet Your Unique Design Needs

BES-TECH TECHNOLOGY & SYSTEM INTEGRATION

Installation, Service, and Troubleshooting Instructions

Model 8142 and 8142NC Fresh Air Ventilator Installation and Operating Instructions

EADQUARTERS. Technical Report One. Stephanie Kunkel Mechanical Option

CARRIER edesign SUITE NEWS. Modeling 100% OA Constant Volume Air Systems. Volume 6, Issue 1. Page 1 Modeling 100% OA Constant Volume Air Systems

RE: Phase 2 Improvements DATE: July 1, 2016 New Administration Building Wernle Youth & Family Treatment Center 2000 Wernle Road Richmond, Indiana

DX Units. Ranging from 15 to 750 tons and 1,000 to 300,000+ CFM

AHRI Guideline W (I-P) 2014 Guideline for Selecting, Sizing, & Specifying Packaged Air-to-Air Energy Recovery Ventilation Equipment

COMcheck Software Version Mechanical Compliance Certificate

Installation and Operation. Tracer ZN521 Zone Controller CNT-SVX07C-EN

DIGI3U. Zoning Systems. Installation Guide. That s all we do. Three-Zone, Universal Controller for Gas/Electric or Heat Pump Applications

Digital Precise Air Control - DPAC

Variable refrigerant flow (VRF) systems

Multi-Path RTU-TYPE 2

Architectural Alliance Incorporated MDP CONSULTING ENGINEERS, INC N 11th Street Beaumont, TX 77702

Introduction. What is a VVT Zone controller?

Technical Report #3 Mechanical Systems Existing Conditions Evaluation

COMcheck Software Version Mechanical Compliance Certificate

AHU Air Handling Unit Fundamentals. j.ilangumaran

Air Conditioning Clinic

Your Home. Jacco & Assoc.

Ventilation Techniques. Topic 5 - Audio 53

12 Pogo Pole Hose Adapter

Premium Efficiency Heat Recovery Unit. D-AHU Modular L. Air Handling Units

Linear Floor Heaters

ASHRAE Guideline 36 Advanced HVAC Control Sequences

ACCUBLOC high performance Heat Recovery

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

Introduction. What is a VVT Zone controller?

Zoning System for Residential Communicating, Variable Air Volume Heating/Cooling Systems

BOOK 2 SPECIFICATIONS

FAARM-Underground Facility. Conceptual Design Review. Mechanical Systems. Dunham Associates, Inc.

EC-BOS-602/616 AX Security

VH Series B ENVIRO-STAC Vertical Hi-Rise Fan Coil Unit with Enhanced Humidity Control

Displacement Ventilation

American University Design Standards

Liquid desiccant dehumidification systems. Product guide

Transcription:

HLR 1000E Technical Specifications May 20, 2016 v3.1 enverid Systems. All rights reserved.

Table of Contents HLR 1000E Module Overview... 3 Weight and Dimensions... 5 System Block Diagram... 6 Electrical Panel... 6 a. Power Requirements... 6 b. Communications... 7 c. Fans & Heaters... 7 d. Required Built-in Connections... 7 e. Additional Built-in Connections... 8 f. Sensors... 8 Installation Specifications... 8 Support... 10 2

HLR 1000E Module Overview The HLR 1000E air treatment system for HVAC load reduction works in all types of buildings, HVAC configurations, and climates. Each module has the following built-in components: D. Inlets and Outlets A. Cartridge Bank E. Shunt F. Control Board B. Heater C. Fans G. Sensors (Quad Sensor) D. Inlets and Outlets H. Insulation (shown in green) A. Cartridge Bank The cartridge bank houses 12 polypropylene cartridges that contain the sorbents used to capture contaminants (CO 2, formaldehyde, VOCs and PM 2.5 ) during the sorption (cleansing) cycle and then release them during the regeneration (outdoor purge) cycle. B. Heater An integrated heater raises the internal temperature of the HLR 1000E to initiate the release of captured contaminants. During this phase, all external dampers are closed, and air is recirculated inside the HLR 1000E to accelerate the release process. C. Fans Integrated DC brushless fans control airflow through the HLR 1000E during the sorption and regeneration cycles. Speed control and active feedback from the fans verify proper operation. 3

D. Inlets and Outlets The HLR 1000E module has two circular inlets and two circular outlets controlled by dampers. The inlets that route the air during sorption are highlighted in green in the schematic above. The outlets that route the air during the purge portion of the regeneration cycle are highlighted in red. E. Shunt The internal shunt used during the heating portion of the regeneration cycle is controlled by a damper that is open only when all other dampers are closed. F. Control Board The electronic enclosure contains the HLR 1000E power supply and controller board. The power supply converts the incoming AC power to the voltages required to operate all aspects of the unit. The controller contains the systems software, all controls/relays/sensor interfaces, and all wireless and wired communication modules. G. Sensors The HLR 1000E unit contains three integrated internal multi-sensor modules used to measure temperature, humidity, CO 2 concentration, formaldehyde, and VOC levels during the sorption and regeneration cycles. The HLR 1000E has two additional temperature and humidity sensors for monitoring the incoming outside air and the supply air from the air handling unit (AHU) to the conditioned space. H. Insulation The inside walls of the HLR 1000E unit are covered in heat-reflective insulation material for improved efficiency and soundproofing. 4

Weight and Dimensions W H L Weight lbs (kg) Unit Cabinet 200 (90.7) Unit with Cartridge Set 400 (181.4) Dimensions Unit with dampers and handles Unit Length (L) 50 (128 cm) 43 (110 cm) Width (W) 27 (68 cm) 25 (63 cm) Height (H) 74 (187 cm) 68 (172 cm) 5

System Block Diagram Electrical Panel a. Power Requirements The HLR module is designed to work with single-phase AC power and can accommodate a range of line voltages and frequencies. Voltage In (Vac) MCA* MOCP* 277 30.58 35.00 240 26.66 30.00 230 25.61 30.00 220 24.55 25.00 208 34.30 35.00 *MCA - minimum current ampacity; MOCP - maximum over-current protection 6

b. Communications Each HLR 1000E module includes state-of-the-art wireless communication capabilities for ongoing monitoring and reporting of indoor air quality, sorbent performance, and system operating conditions. Communications Cellular Link 2.5G/3G Wireless Link 915 MHz c. Fans & Heaters Powerful, lightweight, digitally controlled fans and an integrated heater deliver an effective and efficient variable airflow solution. Voltage/Power Air Flow Components Fan(s) 24VDC/120W (each) Heater with PID control 277VAC/6.5kW 208V/5.5kW d. Required Built-in Connections The HLR 1000E interfaces to the AHU using the following required built-in connections: 1. Outside Air Damper Actuator The HLR 1000E must take control of the outside air (OA) damper actuator to facilitate energy savings and load management. 2. Outside Air Damper Reading The HLR 1000E must read the position signal from the OA damper in order to set it to the correct position. 3. Fire Signal The fire signal is commonly generated from the fire panel or building automation system in the event of a fire in the building. It places the outside air damper, the HLR 1000E, and other air-handling devices in a mode that inhibits smoke/fire from spreading throughout the building through the air ducts. 4. Air Handler Mode The HLR 1000E operates in conjunction with the AHU. Connections OA Damper Control Output from HLR 1000E: 2-10 VDC OA Damper Position Monitoring Fire Signal Dry Contact Input AHU Mode Input Output from HLR 1000E: 2-10 VDC 7

e. Additional Built-in Connections Connections AHU Fan Speed Input BAS* Open OA Damper Input BAS Close OA Damper Input Energy Meter Dry Contact Input Available 24V Relay Output Available Dry Contact Output Available Dry Contact Input Output from HLR 1000E 24V/1A Output from HLR 1000E 1A (max) *BAS - Building Automation System f. Sensors Sensor Function Location Measurement* Multi Sensor Measures incoming air HLR Interior T, RH, C0 2, IAQ Multi Sensor Measures outgoing air HLR Interior T, RH, C0 2 TRH Sensor - AHU Measures energy use SA Duct T, RH OA Duct T, RH Pressure Sensor Measures pressure HLR Interior P Sorbent Temp Measures temperature during regeneration HLR Interior T *Legend: T (temperature); RH (relative humidity); IAQ (Indoor Air Quality); P (pressure) Installation Specifications The HLR 1000E is designed for simple, turn-key installation with physical dimensions that enable each unit to fit through a standard doorway and in a standard elevator. The lightweight module s footprint provides for easy transport and positioning. Three Installation Requirements 1. Electrical power 2. A built-in wireless data connection (A cable must be hooked up during installation for a wired connection) 8

3. Air duct connections: Round control dampers enable quick and cost-effective installation to ducts without transitions. The HLR 1000E has a durable finish, sturdy construction, and reflective insulation, making it compatible with indoor installations. The modules can be located anywhere near the AHU, in the building s mechanical rooms. Modules can be installed vertically or horizontally for easy side-by-side retrofit to existing HVAC infrastructure. The HLR 1000E is designed to handle up to 1000 CFM (cubic feet per minute) of air in a slipstream configuration drawn from the return air path of the HVAC system. The number of modules required for any given building is determined by multiple considerations including contaminant sources, floor space, occupancy, exhaust systems, and building pressurization. A general guideline for office buildings is one HLR 1000E for approximately every 20,000 square feet of floor space; however, only a qualified HLR installation professional can determine the correct number and configuration of units required. Two Installation Options Ducted Return The HLR 1000E module is designed for a slipstream topology a unique feature of the HLR solution. Slipstream topology allows the system to go offline for regeneration or maintenance without any disruption to the building s ventilation systems. The inlet and the outlet of the HLR 1000E module are independently ducted to the indoor air ducts. The flow rate through the HLR 1000E is a small fraction of the total circulation and varies by indoor contaminant load. Plenum Return In plenum-based return air systems, the HLR 1000E module can be positioned inside the plenum with no ductwork for the indoor air. The module pulls in air from the plenum and ejects treated air back into the plenum. In this type of installation, the purge air inlets and outlets must be 9

ducted to an appropriate outside air source and exhaust, respectively. Basic Installation Steps 1. Bring the HLR 1000E and cartridges to the installation area. Note: transport the HLR 1000E and cartridge set in their separate shipping containers 2. Unpack the HLR 1000E and place the module in the orientation required for your installation. Note: the HLR 1000E operates in either a horizontal or vertical configuration. 3. Remove the upper door exposing the cartridge compartment. 4. Install the cartridges per the installation instructions. 5. Install the upper door, closing the cartridge compartment. 6. Connect the four (4) required ducts. Note: All ducts are standard round 14-inch style. 7. Connect the two (2) remote sensors to the HLR1000E unit per the installation instructions. 8. Connect AC power to the HLR 1000E unit per the power requirement instructions. 9. Turn on the HLR 1000E unit using the front panel power switch. 10. Complete the commissioning and testing procedure per the installation instructions. Consult the installation manual and any relevant national and local codes as required. Support For additional support required during installation or operation, please contact enverid Technical Support. Due to ongoing product development and improvements, the specifications contained herein are subject to change without notice. 10