EHPA Testing Regulation

Similar documents
EHPA Testing Regulation

Test Report No.: Page 2 of 14

Technical Note. EHPA Quality Label Model Range Definition Version

AIR CONDITIONERS MINIMUM ENERGY PERFORMANCE, LABELLING AND TESTING REQUIREMENTS FOR LOW CAPACITY WINDOW TYPE AND SINGLE-SPLIT

EXHAUST AIR HEAT PUMPS EVALUATED FOR NORDIC CIRCUMSTANCES

Draft COMMUNICATION FROM THE COMMISSION

The products covered by the Regulation can be classified as follows:

Technical data LA 60TUR+

ETSI Standard Environment Engineering (EE); Thermal Management requirements for outdoor enclosures

0.4 In the preparation of this standard, assistance has been derived from the following standards:

DIN EN , DIN EN , DIN EN , DIN EN

A Notification under Article 12 of Regulation (EU) No 1025/2012 1

INTERNATIONAL STANDARD

Working Document on a possible COMMISSION DELEGATED REGULATION

ENTE CERTIFICAZIONE MACCHINE

DRAFT ECODESIGN REGULATION FOR ENER LOT21 PRODUCTS

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

Energy Efficiency Requirements for Air Conditioners, Chillers and Close Control Units

Multiple split-system air-conditioners and air-to-air heat pumps Testing and rating for performance

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

Performance Rating of Heat Pump Pool Heaters

SPECIFICATIONS FOR THE NF ELECTRICITE PEFORMANCE MARK N LCIE / C AUTONOMOUS STORAGE WATER HEATER WITH ELECTRICALLY DRIVEN COMPRESSOR

HT V2 HT Split

Technical data LA 9S-TU

Daikin Altherma Selection Report

Savings and performance worth celebrating! The DHP-AQ new air source heat pump from Danfoss

Delegated Regulation (EU) 1059/2010 of 28 September 2010 supplementing Directive 2010/30/EU with regard to energy labelling of household dishwashers

ILNAS-EN 50304:2001. Electric ovens for household use - Methods for measuring the energy consumption

(Non-legislative acts) REGULATIONS

Performance Rating of Heat Pump Pool Heaters

Operating Functions Temperature Parameters

Implementation of the Construction Products Regulation (CPR) in harmonized standards - Template for Annex ZA -

Refrigerating Appliance ErP Test Report

This document is a preview generated by EVS

In accordance with the Radio Waves Act Chapter 58 Article 8(3), the document below is a

The test items passed the test specification(s).

Lawnmowers, pedestrian controlled (combustion engine powered)

INTERNATIONAL STANDARD

(Non-legislative acts) REGULATIONS

Performance Rating of Unit Ventilators

Water chillers water/water type SIGMA Technical information manual

REFRIGERAT A OR USE DF1-15 F ridge

ENVIRONMENT-FRIENDLY HEATING WITH R290 HEAT PUMPS. Dr. Joachim Maul - Brussels, 15th of October 2013

WP2 European Product Analysis, Task 2.1 Determining energy efficiency criteria, D 2.1 Periodic Criteria Papers (first set)

Heat pump systems and Chillers

ISO INTERNATIONAL STANDARD. Small craft Airborne sound emitted by powered recreational craft Part 1: Pass-by measurement procedures

INTERNATIONAL STANDARD

Energy Efficiency Schemes Brief Introduction

DRAFT TANZANIA STANDARD

nemo 5,4 30,5 kw 6,4 37,4 kw R410A PLATE water cooled chillers / heat pumps and motoevaporating units COOLING HEATING

INTERNATIONAL STANDARD

Rules for Classification and Construction Additional Rules and Guidelines

ISO INTERNATIONAL STANDARD

SA Series Startup Form

BUSINESS PLAN CEN/TC 49 GAS COOKING APPLIANCES EXECUTIVE SUMMARY

Technical description. Atec.

PAC BT LOW TEMPERATURE HEAT PUMP WITH DHW TANK INCLUDED

High efficiency air to water Heat pumps LZT series

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

COMMISSION REGULATION (EU) / of

Technical data LA 60TU

Working Document on a Draft

CO-ORDINATION OF NOTIFIED BODIES PPE Regulation 2016/425 RECOMMENDATION FOR USE

INTERNATIONAL STANDARD

COMITÉ EUROPÉEN DES ASSURANCES

THE HEAT PUMP CHOICE OF PROFESSIONALS

Technical data LA 28TBS

ANNEXES. to the. COMMISSION REGULATION (EU) No /..

Teknik Data NIBE F2120 8, 12, 16, 20

INTERNATIONAL STANDARD

Implementation of the Construction Products Regulation (CPR) in harmonized standards - Template for Annex ZA -

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

Annex 7: Harmonised Standards for Products covered by Ecodesign and Energy Labelling Regulations. Page 1 of 26

Planning guide. (2010/09) en

Household and similar electrical appliances Safety

HEAT PUMPS SiOS SYSTEM TERMINAL UNITS UNICO CONDITIONER FIXED AIR PORTABLE AIR CONDITIONER AIR COOLER DEHUMIDIFIERS HUMIDIFIERS FAN HEATERS GAS STOVES

Advance Split

Hot Water Heating Systems

Chain saws (electric mains powered and battery powered)

OJ L 239, , p. 1. OJ L 239, , p. 83, OJ L 239, , p. 136.

This presentation is posted for public use. ACEEE does not endorse any product or service.

Official Journal of the European Union L 239/1. (Non-legislative acts) REGULATIONS

MODEL URS-1: FACTORY RETROFIT PROGRAM

38-SDMS-03 SPECIFICATIONS FOR LV DIGITAL PANEL METERS

INTERNATIONAL STANDARD

Garden blowers, vacuums and blower/vacuums (electric mains powered)

Delegated Regulation (EU) 626/2011 of 4 May 2011 supplementing Directive 2010/30/EU with regard to energy labelling of air conditioners

Technical Information

Lawnmowers (pedestrian controlled electric mains-powered)

Update all extract references to NFPA documents (including NFPA 72) in Chapter 3 and related annex material to the latest editions.

Electromagnetic compatibility (EMC)

ENERGY ANALYSIS OF HEAT PUMP WITH SUBCOOLER

COMMISSION IMPLEMENTING REGULATION (EU) /... of XXX

ECB S Recommendation for Service, Repair and Modification Operations on ECB S Certified Secure Storage Units, Data Cabinets and Data Rooms

AS/NZS 3820:2009 (Incorporating Amendment 1) Essential safety requirements for electrical equipment

INTERNATIONAL STANDARD

COMMISSION REGULATION (EU) No /.. of

ISO 7183 INTERNATIONAL STANDARD. Compressed-air dryers Specifications and testing. Sécheurs à air comprimé Spécifications et essais

DESIGN & TECHNICAL MANUAL

Transcription:

EHPA Testing Regulation Testing of Heat Pumps for Domestic Hot Water Production Terms, Test Conditions and Test Method based on EN 16147 Additional requirements for granting the international quality label for heat pumps Version 1.8 Release 01.04.2016 European Heat Pump Association Rue d Arlon 63-67 B-1040 Brussels www.ehpa.org phone +32 24 00 10 17 fax +32 24 00 10 18 info@ehpa.org Page 1 / 8

Revisions of the document Version Date Main changes Clause Page Author 1.7 October 2014 Initial version - Table of modifications - page 2 M. Mondot 1.8 April 2016 Date of the applicable standards 3 page 4 Clarification on the setting of the hysteresis 5.5.1 page 5 Test report 6.3 page 7 M. Mondot EHPA_TestReg DHW-HP_V1.8.doc Version 1.8 April 2016 Page 2 / 8

Contents 1 INTRODUCTION... 4 2 SCOPE OF APPLICATION... 4 3 REFERENCE DOCUMENTS... 4 4 TERMS AND DEFINITIONS... 4 5 TESTS TO BE PERFORMED... 4 5.1 Performance test... 5 5.1.1 Test conditions... 5 5.1.2 Test method... 5 5.2 Sound power level measurement... 6 5.3 Safety tests... 6 6 TEST REPORT LEVEL 1 (DISCLOSURE STATUS: PRIVATE)... 6 6.1 General Information on the testing institute... 7 6.2 Technical data sheet... 7 6.3 Performance test... 7 6.4 Sound measurement... 7 6.5 Safety tests... 7 7 MARKING... 7 EHPA_TestReg DHW-HP_V1.8.doc Version 1.8 April 2016 Page 3 / 8

1 Introduction This regulation specifies the terms and definitions, the test conditions, the performance tests and other requirements for granting the EHPA Quality label for heat pumps for domestic hot water production. The test conditions and testing methods described in this regulation are based on the European standard EN 16147 and EN 12102 and on additional specifications referenced therein. Anything not defined in this regulation shall be proceeded regarding EN 16147. A heat pump can be awarded with the International Heat Pump Quality Label once it is successfully tested in accordance with this regulation. The process is described in the EHPA regulations for granting the international quality label for electrically driven heat pumps. This regulation has been adopted by the EHPA Quality Label Committee, changes of this regulation must also be approved by the Committee. 2 Scope of application The regulation applies to the testing of factory-made electrically driven heat pumps for domestic hot water production under the testing conditions specified in chapter 5. In order to attain the international quality label, the test specimen must be a heat pump manufactured in series production. The heat pump for DHW production can use air, water or brine as a heat source. In case of heat pumps providing both space heating and DHW production, the unit shall be tested and labelled for space heating before to be tested and labelled for DHW production. 3 Reference documents The latest edition of the reference standards (including any amendments) applies. EN 16147: 2011 Heat pumps with electrically driven compressors Testing and requirements for marking for domestic hot water units EN 12102: 2013 Air conditioners, heat pumps and dehumidifiers with electrically driven compressors Measurement of airborne noise Determination of the sound power level 4 Terms and definitions The terms and definitions given in EN 16147 and in EN 12102 apply with the followings: Defrost mode State of the unit in the heating mode where the operation is modified or reversed to defrost the outdoor heat exchanger Defrost cycle Time for which the unit is in the defrost mode 5 Tests to be performed To be granted the heat pump shall perform the following tests: a) Performance test (see chapter 5.1) b) Acoustic test (see chapter 5.2) EHPA_TestReg DHW-HP_V1.8.doc Version 1.8 April 2016 Page 4 / 8

c) Safety tests (see chapter 5.3) 5.1 Performance test Performance test shall be made fully in accordance with EN 16147 for the determination of the following characteristics: - heating up time, t h - coefficient of performance (COP DHW ), - standby power input, P es - reference hot water temperature, θ WH - maximum quantity of usable hot water, V max 5.1.1 Test conditions The performance shall be declared by the manufacturer for one (or more) of the tapping cycles described in EN 16147. Performance testing shall be performed for this(these) tapping cycle(s) and the test conditions given in EN 16147. The hysteresis shall be set according to the manufacturer s instructions in the technical documentation and the value of which is indicated in the application form. 5.1.2 Test method The testing shall be made according to EN 16147 test method with the additional following requirements: The unit shall be delivered to the test house charged with the refrigerant from the manufacturer. For units with variable capacity control, the manufacturer shall specify and declare the settings for testing (frequency or others). For DHW only function units using water or brine as heat source, the flow rate shall be specified by the manufacturer and set before the beginning of the test. For space heating and DHW HPs, the flow rate is set equal to the flow rate measured during the test in heating mode operation at 35 C leaving water temperature. According to EN 16147, the tests can be conducted with or without the supplementary heat supply, according to the manufacturer s specifications. If the manufacturer specifies that the supplementary heat supply shall be switched on during the tests, the test report shall clearly mention that the heater was on during the tests and its power input shall also be recorded. When testing brine/water heat pumps, a brine concentration of 30 % by volume of ethylene glycol, with a freezing point of -15 C shall be used. Note: The concentration shall be checked by the test laboratory against density, freezing point or other properties. In case of an air source heat pump operating in a transient regime due to defrosting, the permissible deviations on air side given in EN 16147 Table 2 shall be replaced by the deviations given in the following Table 1. EHPA_TestReg DHW-HP_V1.8.doc Version 1.8 April 2016 Page 5 / 8

Table 1 Permissible deviations from set values during transient regime Readings Air source temperature: Variations of arithmetical mean values from specified test conditions Variation of individual readings from specified test conditions Interval H Interval D Interval H Interval D - dry-bulb ± 0,6 K ± 1,5 K ± 1,0 K ± 5,0 K - wet-bulb ± 0,3 K ± 1,0 K ± 0,6 K Ambient air temperature ± 1,0 K ± 1,5 K ± 2,0 K ± 5,0 K Interval H is defined as the period when the heat pump is in heating mode, except for the first 10 minutes after termination of a defrost cycle. Interval D is defined as the period including a defrost cycle and the first 10 min after the termination of a defrost cycle when the heat pump is back operating in the heating mode. Note: Table 1 is used in EN 14511 for HPs using outdoor air as heat source 5.2 Sound power level measurement A sound power level measurement shall be performed using one of the acoustic measurement methods described in EN 12102, using Class A method with the following operation of the heat pump. 1. The settings and test conditions shall be the same as for the performance test 2. The heating up period test is performed again in order to measure the sound power level when the water outlet temperature is raised from 35 C to 45 C. The outlet water temperature is checked by small draw-offs. 3. Sound power level measurement starts when the outlet water temperature is reaching 35 C ± 2 K and ends when the outlet water temperature is 45 C± 2K. The test is performed this way for DHW only units. For units providing both space heating and DHW, the sound power level is the one determined for space heating operation. 5.3 Safety tests The safety tests check if the safety devices respond correctly to operational malfunctions and protect the heat pump from damage. The safety devices are tested by simulating operational malfunctions during normal heat pump operation. The safety tests shall be performed according to EN 16147 clause 6.8. 6 Test report Level 1 (disclosure status: private) Production of this test report by the heat pump test centre is part of the overall test procedure. The report is sent only to the manufacturer or the customer who has ordered the tests. The heat pump test centre is allowed to publish the test results only if the applicant has approved such publication with an authorized signature. This test report level 1 shall specify the version of the testing regulation and of the related standards that have been applied. It shall contain all test documents and fulfil the requirements in EN 16147 and EN 12102. In addition, the use of the supplementary heat supply during the tests if any, shall be clearly mentioned with its power input. EHPA_TestReg DHW-HP_V1.8.doc Version 1.8 April 2016 Page 6 / 8

6.1 General Information on the testing institute - Date - Name of the testing institute - Test location - Test supervisor - Test number - Test methods and reference to the EN standards - References to the EHPA regulation and version 6.2 Technical data sheet - Name of the customer (usually the manufacturer) - Machine type, designation - Serial number (if not available, compressor serial number) - Brief description of the design - Information on the components, such as compressor type, heat exchanger type, expansion valve type, etc. - Intermediate heat transfer medium flow rate for indirect systems - Fan speed, air volume flow and maximum permissible external static pressure, where applicable - Nominal volume of the storage tank - Year of production - Photos of the machine - Dimensions and weight of the heat pump - Type and charge of refrigerant: - GWP value of the refrigerant (as required by the EU Ecolabel, 2007/742/EC) 6.3 Performance test The report shall include a description of the heat pump tested and the storage tank including thermostat setting and hysteresis, pump and fan speed, capacity control settings where applicable. It shall include all data recorded as specified in EN 16147 Table 14 as well as the main results as specified in EN 16147 Table 15. 6.4 Sound measurement - Specific requirements for installation of the tested model(s), where applicable - acoustic test method - measured sound power level(s) 6.5 Safety tests - Safety tests passed or failed 7 Marking Each heat pump shall have a durable, permanently fixed marking that is easily readable when the unit is in position for use, bearing at least the information required by the safety standards. If the heat pump consists in several parts the information shall be marked on each of these parts with the model designation of the complementary parts. The name plate shall include the following information: Manufacturer or supplier Type Serial or production number Nominal volume of the tank EHPA_TestReg DHW-HP_V1.8.doc Version 1.8 April 2016 Page 7 / 8

Coefficient of performance (COP DHW ) to 3 significant figures and designation of the test conditions and tapping cycle Type and filling weight of the refrigerant Note: for heat pumps providing both space heating and domestic hot water production, the COP for each function shall be indicated and clearly identified on the nameplate. EHPA_TestReg DHW-HP_V1.8.doc Version 1.8 April 2016 Page 8 / 8