TFI Report Reaction to fire test

Similar documents
TFI Report Classification

TFI Report Classification

Analysis Report

BS EN ISO : 2010

Report VNLF Test Report

BS EN ISO : 2010

BCTC CARPET TECHNICAL CENTRE

Analysis Report

BS EN ISO : 2010

BS EN ISO : Fire Tests For Determination Of The Burning Behaviour of Floorings. WF Report Number. Date: 16 th November 2009.

Test Report No

Classification Report Reaction to fire of building elements DIN EN :2007. Class E

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Reaction to fire testing of Vescom vinyl wall covering with a Fibre Structure, a total weight of 550 g/m 2 according to EN 13823:2002

IMO Resolution MSC 61(67): Annex 1: Part 2

Forbo Flooring Attn. Mr. A. Tijhof Postbus AA Krommenie. Report. Sponsor : Contractor, manufacturer : Forbo Flooring. Lot. No. : 66869/3877.

IMO Resolution MSC 61 (67) 1996; Annex 1, Part 2. Smoke & Toxicity Test. WF Report Number: Date: 13 th August Test Sponsor:

Classification of reaction to fire performance in accordance with BS EN : A1: 2009 on Sandwich Panel, WP 50.

ISO INTERNATIONAL STANDARD. Reaction to fire tests for floorings Part 1: Determination of the burning behaviour using a radiant heat source

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Test Report: ICL/H18/9039 Rev 1

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Test Report: ICL/CR15/11/087

Classification of reaction to fire performance in accordance with EN : A1: 2009 on Superfoil SFNC. Prepared for:

EN : A Report To: Poliuretanos S.A. Document Reference: (Issue 2), (Issue 2) & (Issue 4) Date: 13 th February 2015

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

BS EN ISO 1716: Determination Of The Heat Of Combustion For Building Products

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Reaction to fire classification report No C

~~oeti. Report VN71 O Classification Report. Reference

~,oeti. Report VN Classification Report. Reference

WARRES No Page 1 of 27. Fire Resistance Test Generally In Accordance With BS 476: Part 22: 1987, Clause 5, on an Insulated Fabric Barrier

CERTIFICATE OF APPROVAL No ME 5085

Test report. NanoPhos coating system EPR and EEN. Name of client: NanoPhos SA. Date: Pages: 5 Encl.: 1 Ref: BP / KTO

Fire Testing of Foams

Reaction to fire classification report No C-rev.1

Classification of Fire Performance of Wall and Ceiling Lining Materials

BS EN 13823: A Report To: Contra Vision. Document Reference: Date: 25 th November Issue No.: 1

ISO INTERNATIONAL STANDARD. Reaction to fire tests for floorings Part 1: Determination of the burning behaviour using a radiant heat source

1.0 INTRODUCTION. Shaw Industries Group 2 SwRI Project No c

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

REACTION TO FIRE TESTS FOR BUILDING PRODUCTS DETERMINATION OF THE HEAT OF COMBUSTION ACCORDING TO STN EN ISO 1716: 2003

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

Ad-hoc IEC Ad-hoc investigation to determine the fire performance of a cable junction box, using the principles of IEC

Centrum stavebního inženýrství a.s.

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

Title: Fire resistance test utilising the general principles of BS 476: Part 20: 1987 on four specimens of Uninsulated Air Valves.

TNO report. Centre for Fire Research Van Mourik Broekmanweg 6 P.O. Box AA Delft. T F

NF X : Parts 1, 2, 3, 4 & 5

Review Fire Test Report

Contact person Date Reference Page Richard Johansson P (2) Fire Research

Report VNNF Test Report

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

BS 476: Part 7: 1997 on K-Flex IN Clad Foil. Prepared for: L'Isolante K-Flex Srl Via Leonardo da Vinci, RONCELLO (MB) Italy

ASTM F25 SEMINAR Fire Testing for SOLAS and Navy Vessels New Test Procedures and Materials Approval Process

FRANCE M & F RANKING ACCORDING TO NF F

ISO/TR TECHNICAL REPORT. Reaction-to-fire tests Full-scale room tests for surface products Part 2: Technical background and guidance

BS 476: Part 3: External Fire Exposure Roof Test. WF Report Number: Date: 28 th April Test Sponsor: Tapco Europe Limited

ISO INTERNATIONAL STANDARD. Reaction to fire tests for floorings Part 1: Determination of the burning behaviour using a radiant heat source

Tech Notes. TESTING PROTOCOL Fire Retardant Gel Coats. INTERPLASTIC CORPORATION Thermoset Resins Divison ISSUE 5

Test Report No. AJHG FB Date: FEB.17, 2015 Page 1 of 13

BS 476: Part 6: 1989+A1:2009

Test on extruded rigid PVC profile for concrete formwork at 50 kw/m² irradiance in

CAN/ULC-S102 Surface Burning Characteristics of "Digitally Printed Aluminum Siding" Coated Aluminum

Global flammability standards.

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

FIRST-CLASS IN TRAINS

Additional Reaction to Fire Classification Report

Ad-hoc IEC Ad-hoc investigation to determine the fire performance of a cable junction box, using the principles of IEC

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Test Report Reg.no 12.

BS EN : 2001 & IEC :2000

SOUTH AFRICAN NATIONAL STANDARD

New European Fire Testing Classification for Construction Products

ISO 5657 INTERNATIONAL STANDARD. Reaction to fire tests Ignitability of building products using a radiant heat source

European Technical Assessment ETA-14/0176

Procedure for the Approval of New Fire Detection and Alarm Technologies

TEST REPORT DATE: TEST NUMBER: DESCRIPTION OF TEST SAMPLE

Classification report

In Search of Standard Reference Materials (SRMs) for ASTM E05 Fire Standards by. Norman Alvares & Harry Hasegawa

BS 476: Part 6: 1989+A1:2009

BS EN 13823: A Report To: Durabuild Technologies Pvt. Limited. Document Reference: Date: 22 nd February Issue No.

BS 476: Part 3: External Fire Exposure Roof Test. WF Report Number: Date: 13 th October Test Sponsor: Tapco Europe Limited

CAN/ULC-S102 Surface Burning Characteristics of "8 mm Fire Rated High Pressure Laminate Phenolic Panel"

List of tests (2018)

Title: Indicative fire test. WF Report No: /A. Prepared for: Hoody Speaker Hoods Ltd

MANSION A HAND-PICKED COLLECTION FOR LUXURY LIVING

Annex to the Accreditation Certificate D PL according to DIN EN ISO/IEC 17025:2005

Annex to the Accreditation Certificate PL according to DIN EN ISO/IEC 17025:2005

Benefiting Government, Industry and the Public Through Innovative Science and Technology. Barry L. Badders, Jr. P.E.

ISO INTERNATIONAL STANDARD

Fire Test Methods ASTM NFPA UL ISO IEC

ASSESSMENT OF FIRE BEHAVIOUR OF TIMBER PARTITION MATERIALS WITH A ROOM CALORIMETER

Fire Safety Fire Resistant Building Components

MEDIUM-DENSITY HOUSING # 7. Fire safety

Centrum stavebního inženýrství a.s.

In accordance with: Period of Fire Resistance: 180 minutes (3 hours) integrity (single) 120 minutes (2 hours) integrity (overlapped)

SHAW CONTRACT DESCRIPTION OF TEST SAMPLE

Transcription:

TFI Report 450740-07 Reaction to fire test For the classification according to EN 13501-1:2010 Customer GÜLSEVEN HALI GÜLSEVEN TEKSTIL KIMYA GIDA SAN. TIC. LTD. STI Ahi Evran Sanayi Sitesi Istiklal Caddesi No:41 45900 Demirci/Manisa TURKEY Product textile floor covering ELITE Responsible at TFI Dipl.-Ing. Ulrike Balg Tel: +49 241 9679 133 u.balg@tfi-online.de Aachen, 29 May 2015 This report includes 2 pages and 3 annexes. This report is a transcription of test report no. 450740-05. The present document is provided with a qualified electronic signature and is valid without autograph signature. This report only applies to the tested specimens and has been established to the best of our knowledge. Only the entire report shall be reproduced. Under no circumstances, extracts shall be used. Furthermore, we apply the General Terms and Conditions for the Execution of Contracts of the Textiles & Flooring Institute GmbH, also with regard to the order execution.

450740-07 1 Transaction Test order Order date 22 April 2015, 29 May 2015 Your reference Product designation Reaction to fire test for construction products according to EN ISO 9239-1:2010 B. Gülseven ELITE TFI sample number 15-05-0013 Date of manufacture not specified Date of sample receipt 04 May 2015 Sampling performed by 2 Product Specification cf. annex KT 3 Results Customer Burning behaviour using a radiant heat source according to EN ISO 9239-1:2010 Average critical heat flux [kw/m²] 7.9 Integrated smoke density [% x min] 44 Adhesion Substrate according to EN 13238:2010 none fibre cement board This test report is the basis for a classification report according to EN 13501-1:2010. The test results relate to the behaviour of the test specimens of a construction product under the particular conditions of the test; they are not intended to be the sole criterion for assessing the potential fire hazard of the construction product in use. 4 Annexes Photographs F 450740-07 Characteristics of the construction product a KT 450740-07 Reaction to Fire a RP 450740-07 The annexes marked a are based on tests accredited in accordance with EN ISO/IEC 17025. Page 2 of 2

F 450740-07 Annex F - Photographs 1 Transaction Product designation ELITE TFI sample number 15-05-0013 Testing period 27 May 2015 2 Test Method / Requirements -not specified- 3 Results 3.1. Specimen 1, in production direction 3.2. Specimen 2, in production direction Page 1 of 2

F 450740-07 3.3. Specimen 3, in production direction 3.4. Specimen 4, cross production direction Page 2 of 2

KT 450740-07 Annex KT Characteristics of the construction product 1 Transaction Product designation ELITE TFI sample number 15-05-0013 Testing period 26 May 2015 2 Test Method / Requirements ISO 1765:1986 ISO 8543:1998 Deviation Machine-made textile floor coverings Determination of thickness Textile floor coverings Methods for determination of mass Indication of mean values instead of individual results 3 Results Parameter Manufacturer's data TFI results Type of manufacture woven woven Type of surface cut pile cut pile Backing woven textile backing (jute and polyester cotton compound) finish Pattern - none - multicoloured, patterned Colour - none - blue, beige, red, dark blue Use surface 100 % wool not tested Type of delivery broad loom broad loom Total thickness [mm] 15 16.0 Thickness of pile above the substrate [mm] 12 not tested Total mass per unit area [g/m²] 4200 ± 5 % 4043 CV= 0.6 % CV=Coefficient of Variation Page 1 of 1

RP 450740-07 Annex RP Reaction to Fire 1 Transaction Product designation ELITE TFI sample number 15-05-0013 Testing period 27 May 2015 2 Test Method / Requirements EN ISO 9239-1:2010 Part 1 Determination of the burning behaviour using a radiant heat source Substrate according to EN 13238:2010 Fibre cement board Adhesion - none - Joint according to EN ISO 9239-1:2010 No Conditioning Conditioning to constant mass according to EN 13238:2010 Deviation - none - 3 Results cf page 2-5 Page 1 of 5

RP 450740-07 (page 2 of 5) Annex RP - Burning behaviour Sample designation 15-05-0013 Sample Sample No.: 1 Direction: in production direction Observation molten/singed during pre-radiation up to 210 mm buckled/contracted from pilot flame area up to 0 mm penetration of flame through substrate - transitory flaming - blistering - glowing, after flame has extinguished - Results Position Time Heat Flow [mm] [min:s] [kw/m²] 50 02:06 12.44 100 02:26 11.42 150 02:39 10.40 200 03:02 9.38 250 04:05 8.30 300 - - 350 - - 400 - - 450 - - 500 - - 550 - - 600 - - 650 - - 700 - - 750 - - 800 - - 850 - - 900 - - 950 - - 1000 - - Time Position Heat Flow [min:s] [mm] [kw/m²] 10:00 275 7.74 20:00 - - 30:00 - - [%] 100 80 60 40 20 0 Smoke density 0 3 6 9 12 15 18 21 24 27 30 Zeit [min] CHF [kw/m²] 7.74 HF_30 [kw/m²] 0.00 Smoke density integral [%*min] 47.5 Flame extinguished after [min:s] 12:02 max. burnt distance [mm] 275 max. light attantuation [%] 23.0

RP 450740-07 (page 3 of 5) Annex RP - Burning behaviour Sample designation 15-05-0013 Sample Sample No.: 2 Direction: in production direction Observation molten/singed during pre-radiation up to 210 mm buckled/contracted from pilot flame area up to 0 mm penetration of flame through substrate - transitory flaming - blistering - glowing, after flame has extinguished - Results Position Time Heat Flow [mm] [min:s] [kw/m²] 50 02:05 12.44 100 02:11 11.42 150 02:31 10.40 200 02:48 9.38 250 03:25 8.30 300 - - 350 - - 400 - - 450 - - 500 - - 550 - - 600 - - 650 - - 700 - - 750 - - 800 - - 850 - - 900 - - 950 - - 1000 - - Time Position Heat Flow [min:s] [mm] [kw/m²] 10:00 262 8.03 20:00 - - 30:00 - - [%] 100 80 60 40 20 0 Smoke density 0 3 6 9 12 15 18 21 24 27 30 Zeit [min] CHF [kw/m²] 8.03 HF_30 [kw/m²] 0.00 Smoke density integral [%*min] 46.8 Flame extinguished after [min:s] 12:54 max. burnt distance [mm] 262 max. light attantuation [%] 24.3

RP 450740-07 (page 4 of 5) Annex RP - Burning behaviour Sample designation 15-05-0013 Sample Sample No.: 3 Direction: in production direction Observation molten/singed during pre-radiation up to 210 mm buckled/contracted from pilot flame area up to 0 mm penetration of flame through substrate - transitory flaming - blistering - glowing, after flame has extinguished - Results Position Time Heat Flow [mm] [min:s] [kw/m²] 50 02:05 12.44 100 02:12 11.42 150 02:30 10.40 200 02:58 9.38 250 03:32 8.30 300 - - 350 - - 400 - - 450 - - 500 - - 550 - - 600 - - 650 - - 700 - - 750 - - 800 - - 850 - - 900 - - 950 - - 1000 - - Time Position Heat Flow [min:s] [mm] [kw/m²] 10:00 257 8.14 20:00 - - 30:00 - - [%] 100 80 60 40 20 0 Smoke density 0 3 6 9 12 15 18 21 24 27 30 Zeit [min] CHF [kw/m²] 8.14 HF_30 [kw/m²] 0.00 Smoke density integral [%*min] 38.8 Flame extinguished after [min:s] 12:32 max. burnt distance [mm] 257 max. light attantuation [%] 21.7

RP 450740-07 (page 5 of 5) Annex RP - Burning behaviour Sample designation 15-05-0013 Sample Sample No.: 1 Direction: cross production direction Observation molten/singed during pre-radiation up to 210 mm buckled/contracted from pilot flame area up to 0 mm penetration of flame through substrate - transitory flaming - blistering - glowing, after flame has extinguished - Results Position Time Heat Flow [mm] [min:s] [kw/m²] 50 02:08 12.44 100 02:13 11.42 150 02:22 10.40 200 02:43 9.38 250 03:13 8.30 300 - - 350 - - 400 - - 450 - - 500 - - 550 - - 600 - - 650 - - 700 - - 750 - - 800 - - 850 - - 900 - - 950 - - 1000 - - Time Position Heat Flow [min:s] [mm] [kw/m²] 10:00 272 7.81 20:00 - - 30:00 - - [%] 100 80 60 40 20 0 Smoke density 0 3 6 9 12 15 18 21 24 27 30 Zeit [min] CHF [kw/m²] 7.81 HF_30 [kw/m²] 0.00 Smoke density integral [%*min] 45.5 Flame extinguished after [min:s] 13:16 max. burnt distance [mm] 272 max. light attantuation [%] 23.7