DIVA8MG2. Compact PAVA System Master Unit. DIVA8 System

Similar documents
16 Zone Voice Evacuation VA & PA Sound System

VM-3000 SERIES INTEGRATED VOICE EVACUATION SYSTEM

WW Ability to connect standalone minives units. Integrated mini PA/VA unit. We make everyday life safer. (incl. fireman and zone microphones)

Entero Voice Alarm system.

VX-2000 SERIES INTEGRATED VOICE EVACUATION SYSTEM

Voice Alarm. Multifunctional Voice Alarm Systems. certified to EN54

Experts in PA/VA Systems

VX-2000 SERIES INTEGRATED VOICE EVACUATION SYSTEM

by Honeywell VOICE ALARM SOLUTIONS BROCHURE

Microphones VIGIL VIGIL. Unitouch. combined data sheets LEADING THE WAY TO SAFETY

Entero Voice Alarm system. User guide

DCA4. Digitally controlled Audio Matrix. Current Thinking. Product Specification March Document Number DDC DCA ACS

AE300. Integrated Voice Alarm System

Call stations and extensions

PUBLIC ADDRESS, BACKGROUND MUSIC AND VOICE ALARM SYSTEM

APPLICATION DATA SHEET

Solutions for Mass Notification Systems

Vocia VACIE. Reference Guide

VACIE REFERENCE GUIDE REVISION 1.2.6

GUARDIAN CX10 PRIORITY/EVACUATION INTERFACE USERS MANUAL

APPLICATION DATA SHEET

TABLE OF CONTENTS. HEADQUARTERS Severo Ochoa, Málaga, Spain Tel / Fax

LOCAL & GLOBAL. Voice Alarm System. Smart public address system.

Bosch Plena Public Address and Voice Alarm System The fast route to safety

SP40S-D. Kingfisher Company, inc. Features: Description:

CFDAU30 Voice Alarm System

Prem1er EVACS16. Installation Manual VOICE ALARM CONTROL PANEL 4 16 ZONES

PUBLIC ADDRESS SYSTEM

X-618 Digital Public Address and Voice Alarm System. Cherian George Product Manager PAVA systems

IEC Electroacoustic EMERGENCY WARNING SYSTEM. for a maximum of system security 79

N-8000 SERIES IP INTERCOM SYSTEM

Public Address Project Combisound System

VOICE ALARMING SYSTEM»ONE-BOX-DESIGN« EN / EN 54-4 / VDE / EN / VDE 0828 THE SIMPLE»ALL-IN-ONE«SOLUTION.

Operating Manual IMPORTANT NOTE: A A 4585 Zone Paging System. A A 4586 Paging Console (Optional)

tyco PAVA IP Audio Voice Alarm Router tyco PAVA Systems Features : K ƉƟŽŶĂůD ŽĚƵůĞƐ

ECC-50/100C. Emergency Command Center

EN ASTRO-PA/GA System. ASTRO-PAGA Digital IP Public Address & General Alarm SYSTEM for INDUSTRIAL SAFETY APPLICATIONS

PA/VA solutions for transport industry

LB3-PCx50 Premium Cabinet Loudspeakers

EvacU Emergency Warning Control and Indicating Equipment (Occupant Warning Systems) Technical Manual MAN3072-5

OPERATING INSTRUCTIONS VOICE EVACUATION SYSTEM FS-7000 SERIES

EvacU Emergency Warning Control and Indicating Equipment (Occupant Warning Systems) Technical Manual MAN3072-9

Application Guide YOGA STUDIO. Yoga Studio Zone. Page 1. JBL Commercial CS SERIES. Generic Copper Wire Mic/Line Cable

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel

NetSOLO Broadband. Voice Evacuation. Intelligent, Networked, Multi-Channel Fire Alarm Control and Emergency Voice Evacuation System

GAI-Tronics Systems NEW! Elemec3 Digitally Controlled PA and General Alarm system PA/GA

Elemec3. Networked Public Address and General Alarm System (PA/GA)

E3 Series Broadband. Description. Features. Intelligent, Networked, Multi-Channel Fire Alarm Control and Emergency Voice Evacuation System

Multi-Graphic MCPB & Series 115B, 2223R, & 2233R

Entero ESC emergency system controller

ECC-50/100(E) Emergency Command Center. General. Features. Emergency Voice Evacuation TYPICAL APPLICATIONS

E3 Series Broadband System

AUDIO- AND ALARMMANAGEMENT

Proel is a leading international company specialising in the design, production and distribution of audio, video and lighting systems for the world

TrueCom. Building Communications Systems 5115-Series , Area of Rescue Communications System. Description

GAI-Tronics Corporation. Serverless Page Party (SP2) Publication : SP2 Intelligent Intra-Plant Communication and Emergency Notification System

Autonomous control unit

Get all messages across, no matter what.

Promatrix 6000 I EN de I 1. ISO7240 PAVIRO. Installer checklist

Voice Alarm system integration

E3 Series Broadband System

EasyAlarm ELEVATOR LEITRONIC AG

Bosch Plena Public Address and Voice Alarm System The ease of amplification

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING

Intelligent addressable fire alarm control panel

POPE FRANCIS HIGH SCHOOL SPRINGFIELD, MA BID SPECIFICATION PUBLIC ADDRESS AND INTERCOM SYSTEM

SAFEPATH DoD facility communications system & expansion options

_5120_School_Intercom_Rack_Spec.doc 09/21/04

FI6000 INSTRUCTION MANUAL. Thank you for choosing another quality product from Amperes Electronics. Fire Alarm Interface

5120_School_Intercom_Rack_Spec.doc 10/10/07

ECC-50/100(E) Emergency Command Center

SAFEPATH Mass Notification System (SPMNS)

Alarm Tone Generator Model AG17

PREMIER EVACS 1-16 INSTRUCTION MANUAL: 2-ZONE NETWORKED VOICE ALARM PANEL INSTALLATION MANUAL

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

INTEGRITY VOICE ALARM ROUTING MATRIX

EXICALL EN70 EXICALL EN70MR EXICALL EN70-ATEX

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

DOCUMENTATION HANDBOOK MPA 1600 PUBLIC ADDRESS AND GENERAL ALARM SYSTEM.

The Ultimate, Digital Public Address & Voice Alarm System FLEXIBILITY UNLIMITED

SOHO X. 4" Two-way passive system

Sentry G3 Machinery Protection Monitor

Intelligent Security & Fire Ltd

Make your messages heard. Digital Public Address and Voice Evacuation system

SUPREMATouch. Modular Fire & Gas Detection System

AutroVoice voice alarm system AUTROVOICE VOICE ALARM. Loud and clear information

LB3 Premium Cabinet Loudspeakers

Sentry G3 Machinery Protection Monitor

SUPREMATouch. Modular Fire & Gas Detection System

July 14, 1999 DF C-100.

NetSOLO Classic. Voice Evacuation. Intelligent, Networked, Multi-Channel and Bulk Amplification Voice Evacuation System FEATURES & BENEFITS.

Added password for IP setup page : Password must be in IP format!

We make everyday life safer.

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

P R O D U C T D ATA S H E E T

Notification. Public Address & Voice Alarm Systems

SOUND SYSTEMS NEW PRODUCTS

RACK MONITORING SYSTEM - RAMOS Ultra

June 10, 2002 DF C S2424

LORAIN CIP 4890/48120 DC Power System

Transcription:

DIVA8MG2 Public Address - Voice Alarm Audio Distribution over IP Commercial Audio Intelligent Acoustic Solutions Intercommunication Loudspeakers Compact PAVA System Master Unit DIVA8 System DIVA8 system is a compact PAVA solution specifically designed for small to medium-scale installations. It has all the essential functionality to comply with EN 54 requirements for Voice Alarm, including full system monitoring, loudspeaker line impedance surveillance, microphone surveillance and monitored interfacing with remote devices. DIVA8 responds to Public Address and Voice Alarm requirements as stated in EN54-16, ISO 7240-16 and BS5839/8, with specific attributes for compliance in large installations.

D e l i v e r i n g Y o u r M e s s a g e

DIVA8M G2 Compact PAVA system MASTER UNIT DIVA8 system is a compact PAVA solution specifically designed for small to medium-scale installations. It has all the essential functionality to comply with EN 54 requirements for Voice Alarm, including full system monitoring, loudspeaker line impedance surveillance, microphone surveillance and monitored interfacing with remote devices. DIVA8 responds to Public Address and Voice Alarm requirements as stated in EN54-16, ISO 7240-16 and BS5839/8, with specific attributes for compliance in large installations. Main characteristics DIVA8 System Master Public address and emergency sound system control unit 8-zone system controller with individual volume controls per channel 2 channel audio distribution for Paging and BGM Combined back-up amplifier function 5 audio inputs 2 x 1000 Watt maximum load Enhanced loudspeaker line surveillance for A/B zoned installations 9 monitored control inputs 8 logic control inputs Ethernet interface for configuration, control, diagnostics and logging Third party control Connectivity The DIVA8M G2 Master unit provides enhanced digital audio processing (DSP), a digital message player, a fully monitored fireman s microphone, amplifier monitoring with switchover to backups and loudspeaker line monitoring for 16 audio lines (8 lines A/B). It can process and route one PSS-G2, CD8-G2 or CD16-G2 microphone console or up to eight cascaded PSM8-V3 paging microphones, along with two 0dB audio inputs and one mic/line input into two different channels (music + voice) using configurable priorities. The DIVA8 system utilises two external amplifier channels with a maximum capacity of 1000 W each. Pre-processing All audio inputs feature contact and VOX activation and each input is fitted with volume controls and equalisers. Up to 45 minutes of digital messaging can be stored in the unit. These are stored as WAV files and uploaded directly from a PC into the DIVA8M G2. Up to two messages can be played simultaneously in different zones for phased evacuation. Interfacing DIVA8M G2 has nine monitored alarm inputs which can be individually programmed for specific message/input routing to all or selected channels. Each DIVA8 system module has eight output zones with A/B wiring and each zone can be routed manually or automatically to one of the system s audio channels (music or voice). The number of zones can be extended up to 128 A/B zones with the addition of DIVA8S G2 Slave units (up to a maximum of 15 slave units). The music source can be selected directly from the front panel and switched into each zone separately and a rear-panel RS232 port allows third-party control and interfacing. Digital storage for up to 45 minutes of pre-recorded messaging Stores the last 999 fault events 3,5 colour touch-screen EN54-16 certified 3

DIVA8M G2 Compact PAVA system MASTER UNIT Redundancy In case of Evacuation, the amplifier music channel can be used as a second alarm channel. Each DIVA8 system requires only one 2-channel amplifier (one channel for music, one for voice). The music amplifier will also act as a backup amplifier in case of voice amplifier failure. Each channel can handle up to 1000W audio power (at 100V). From the DIVA8M G2 front panel the user can manually route the fireman s microphone signal and three digital messages into selected zones, adjust the audio level and switch (ON/OFF) the music in each zone separately. In case of evacuation, the zone attenuators are automatically bypassed. One output contact per zone can be activated each time the zone is occupied with a source that has higher priority than the music (alarm or microphone paging). Security In accordance with EN54-16, ISO 7240-16 and BS5839/8, all DIVA8 system components and peripherals are monitored. This monitoring extends from the capsule of a paging station microphone to the end of a loudspeaker line. The external cables connected to the control inputs are monitored for short and open circuit and an internallygenerated pilot tone is available for monitoring impedance on the loudspeaker lines. The master unit monitors the status of all the equipment in the system, reports status changes and stores the last 999 fault messages in the system. This log can be accessed on the master unit display or on a PC using the DIVA8 control software. DIVA8 system units operate either on mains power or on a 24V battery power supply for emergency back-up, with automatic switchover. Both power supplies are monitored. Interconnections Installation Notes 4

DIVA8M G2 Compact PAVA system MASTER UNIT Controls and indicators Front 3,5 full colour touch-screen LCD display Zone selection buttons EVAC-start Fireman s microphone Status indicators Rear Voltage selector Interconnections Front Fireman microphone Rear Mains input Battery backup input 8 EVAC inputs 9 control inputs 2 fault inputs 8 control outputs 1 remote Fireman s mic input 4 analogue line audio inputs Ethernet connection 8 zone 100 Volt outputs (A+B) 1 monitored paging console input Certifications and Approvals Region Certifications Parts Included Quantities Components 1 DIVA8M G2 Master unit 1 Fireman s microphone 1 Power cord 1 Set of connectors 1 Set of 19 rackmount brackets 1 DIVA8-system software Technical Specifications Electrical Mains power supply Voltage Power consumption Battery power supply Voltage Performance Frequency response Audio Line inputs Connector Frequency response S/N THD Input range Input impedance 115 or 230 VAC ±15%, 50/60 Hz 48 W 18-26 VDC -3 db @ 20 Hz and 20 khz 2 x 2x2 RCA (un-balanced) -3 db @ 20 Hz and 20 khz >76 db (Line-level) >78 db (Mic-level) < 0,02% @ 1 khz 770 mv (0 dbu to -60 DBU) 10 kohm Monitor loudspeaker Frequency response S/N THD Signal Amplifier lines in Max rated output power Frequency response Input level Loudspeaker lines out -3 db @ 200 Hz and 10 khz >70 dbu < 5% @ 1 khz @ 8ohm 16 dbu 2 x 100 V 1000 W (cont. at 40 C) -3 db @ 50 Hz and 18 khz 16 dbu 16 x Rated load resistance 100 ohm (100 V) Rated power Mechanical Dimensions (H x W x d) for 19 rack use, with brackets Weight DIVA8M G2 Mounting Colour Environmental Operating temperature Storage temperature 100 W (cont. at 40 C) 88 x 483 x 338 mm 7.5 kg (16,5 lb) 19 -rackmount RAL7016 Relative humidity 15% to 90% -5 ºC to +55 ºC (+23 ºF to +131 ºF) -40 ºC to +70 ºC (-40 ºF to +158 ºF) Europe CE CE 0359 (Intertek) Immunity according to EN50103-4 PAVA EN54-16 certified 2012 Fireman s microphone Connector Frequency response 1 x 5-pin locking-din -3 db @ 200 Hz and 10 khz Ordering information DIVA8M G2 Master unit S/N >70 dbu THD < 1% @ 1 khz Signal -40 to -30 dbu Output impedance 10 kohm 5

DIVA8M G2 Compact PAVA system MASTER UNIT 1. Global EVAC 2. Power indicator 3. Navigation buttons 4. RESET button 5. 3.5 touch-screen 6. Navigation buttons 9. All Call & Cancel button 10. ALERT & TEST button 11. BGM control and selection buttons 12. System status indicators 13. Zone attenuator rotary knobs 14. Zone selection buttons 7. Zone status indicators 8. Fireman s microphone on hook 15. Monitor loudspeaker (behind fireman s mic) (Audible warning) 1. Control inputs 2. Evacuation inputs 3. RS232 connector 4. Ethernet connector 5. Power MAINS 6. Logic outputs 7. EVAC & FAULT contacts 8. Amplifier I/O 9. 100 V signal links 10. Speaker zone outputs (A+B lines) 11. Paging console input 12. Master Slave link 13. Remote Ext. connector 14. Mic/Line input 15. Music inputs 16. External fireman s mic Input 17. 24 VDC backup supply input 6

DIVA8S G2 Compact PAVA system SLAVE UNIT DIVA8 system is a compact PAVA solution specifically designed for small to medium-scale installations. It has all the essential functionality to comply with EN 54 requirements for Voice Alarm, including full system monitoring, loudspeaker line impedance surveillance, microphone surveillance and monitored interfacing with remote devices. DIVA8 responds to Public Address and Voice Alarm requirements as stated in EN54-16, ISO 7240-16 and BS5839/8, with specific attributes for compliance in large installations. Main characteristics DIVA8-System Master Public address and emergency sound system slave unit 2 channel audio distribution for Paging and BGM combined back-up amplifier function 5 audio inputs 2 x 1000 Watt amplifier inputs Enhanced loudspeaker line surveillance for A/Bzoned installations 9 monitored control inputs 8 logic control inputs Ethernet interface for configuration, control, diagnostics and logging EN54-16 certified Connectivity The DIVA8S G2 Slave unit is an extension unit for the DIVA8M G2 Master. It increases the number of paging zones by 8 zones for each slave unit added in the system. Up to 15 slave units can be added per DIVA8 system and must be used in conjunction with the DIVA8M G2 Master. A complete DIVA8 system provides up to 128 zones (A/B). Slave units are linked to the system master via shielded CAT-5 cable (max. length 100m). The DIVA8S G2 Slave handles the same 1000 W power capacity as the master unit (at 100V) on each amplifier channel (music + voice). Each zone can be routed manually or automatically to either channel. For maximum flexibility connected amplifiers can distribute their power across multiple slaves or additional amplifier channels can be added to the system to assist where more output power is needed. The 100 V amplifier signal is simply linked to the slaves to create a 100 V signal bus. Interfacing DIVA8S G2 extends the number of input and output contacts available in the system. It includes nine alarm inputs triggered either by dry contact or relay (software-selectable), eight logic contact inputs, two external fault contact inputs and eight contact outputs. Redundancy In case of Evacuation, the amplifier music channel can be used as a second alarm channel. Each DIVA8 system requires only one 2-channel amplifier (one channel for music, one for voice). The music amplifier will also act as a backup amplifier in case of voice amplifier failure. Each channel can handle up to 1000 W audio power (at 100 V). From the DIVA8M G2 Master unit front panel the user can manually route the fireman s microphone signal and three digital messages into selected zones, adjust the audio level and switch (ON/OFF) the music in each zone separately. In case of evacuation, the zone attenuators are automatically bypassed. One output contact per zone can be activated each time the zone is occupied with a source that has higher priority than the music (alarm or microphone paging). 7

DIVA8S G2 Compact PAVA system SLAVE UNIT Interconnections Security In accordance with EN54-16, ISO 7240-16 and BS5839/8, all DIVA8 system components and peripherals are monitored. This monitoring extends from the capsule of a paging station microphone to the end of a loudspeaker line. The external cables connected to the control inputs are monitored for short and open circuit and an internallygenerated pilot tone is available for monitoring impedance on the loudspeaker lines. The master unit monitors the status of all the equipment in the system, reports status changes and stores the last 999 fault messages in the system. This log can be accessed on the master unit display or on a PC using the DIVA8 control software. DIVA8 system units operate either on mains power or on a 24V battery power supply for emergency back-up, with automatic switchover. Both power supplies are monitored. Installation Notes Single amplifier with single back-up Multiple amplifier with single back-up Single amplifier set Multiple amplifier sets 1000 Watt System 3 x 1000 Watt System 1000 Watt System 3 x 1000 Watt System 8

DIVA8S G2 Compact PAVA system SLAVE UNIT Controls and indicators Front Zone selection buttons Zone status indicators Interconnections Rear AC Mains input 24 V DC Battery backup input 9 EVAC inputs 8 control inputs 2 fault inputs 8 control outputs Master to Slave link 8 zone 100 Volt outputs (A+B) Certifications and Approvals Parts Included Quantities Components 1 DIVA8SG2 Slave unit 1 Power cord 1 Set of connectors 1 Set of 19 mounting brackets Technical Specifications Electrical Mains power supply Voltage 115 or 230 VAC ±15%, 50/60 Hz Power consumption 35 W Battery power supply Voltage 18-26 VDC Performance Frequency response -3 db @ 20 Hz and 20 khz Amplifier lines in Max rated output power Frequency response Input level 2 x 100 V 1000 W (cont. at 40 C) -3 db @ 50 Hz and 18 khz 16 dbu Loudspeaker lines out 16 x Rated load resistance 100 ohm (100 V) Rated power 100 W (cont. at 40 C) Mechanical Dimensions (H x W x d) for 19 rack use, with brackets Weight DIVA8SG2 Mounting Colour 44 x 483 x 277 mm 3.9 kg (8.6 lb) 19 -rackmount RAL7016 Region Certifications Europe CE CE 0359 (Intertek) Immunity according to EN50103-4 PAVA EN54-16 certified 2012 Environmental Operating temperature -5 ºC to +55 ºC (+23 ºF to +131 ºF) Storage temperature -40 ºC to +70 ºC (-40 ºF to +158 ºF) Relative humidity 15% to 90% Air pressure 600 to 1100 h Pa Ordering Information DIVA8SG2 Slave unit 9

DIVA8S G2 Compact PAVA system SLAVE UNIT 1. Power indicator 2. Zone status indicators 3. Zone selection buttons 1. Control inputs 2. Evacuation inputs 3. Master Slave link 4. 24 V DC backup input 5. Speaker zone outputs (A+B lines) 6. 100 V signal links 7. Terminator switch (Last slave in the line) 8. Slave-ID rotary switch 9. Logic outputs 10. AC power input 10

D e l i v e r i n g Y o u r M e s s a g e

Public Address - Voice Alarm Audio Distribution over IP Commercial Audio Intelligent Acoustic Solutions Intercommunication Loudspeakers DIVA8S G2 Compact PAVA System Slave Unit ATEÏS Europe B.V. Sydneystraat 42-3047 BP - ROTTERDAM - NETHERLANDS Phone: +31 (0)10 2088690 - Fax: +31 (0)10 2088699 www.ateis-europe.com info@ateis-europe.com ATEÏS reserve the right to change specifications without notice HELPROD.COM - Product pictures, Robert Peek Fotografie - Fotolia