Battery Powered Digital Mass Flow Meters for Gases

Similar documents
Battery Powered Digital Mass Flow Meters for Gases

Battery Powered Digital Mass Flow Meters for Gases

Instruction manual red-y compact series

MS4525DO SPECIFICATIONS FEATURES APPLICATIONS

86BSD Digital Output

PRODUCT TRAINING MODULE: Honeywell Zephyr Airflow Sensors HAF Series High Accuracy

Dimensions. Model Number 123. Electrical connection. Features. Indicators/operating means. Product information RMS-G-RC-NA.

Standard SPECIFICATIONS FEATURES APPLICATIONS

86BSD Digital Output

Dimensions. Electrical connection. Model Number. Features. Indicators/operating means. Product information RAVE-D. Radar sensor

MS1471 SPECIFICATIONS. PC Board Mountable Pressure Sensor 0-60 mv Output Gage and Absolute Low Cost

GMH 285 / GMH 285-BNC

Distributed By: M&M Control Service, Inc Building Technologies

More Precision. thicknesssensor // The sensor for precise thickness measurements

Pressure Transducers Ultrahigh-Purity

Accurate, cost-saving and reliable Natural gas analyzer SITRANS CV SITRANS CV. Answers for industry.

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

86BSD Digital Output

Danfoss gas detection unit Type GD Heavy Duty

4500MkIII COMPLIANCE OPACITY AND DUST MONITORING QAL 1 PS-1 ASTM D6216 PROCEDURE 3 PS-11 QUALITY CUSTOMER SOLUTIONS

SEC SIGNATURE ETO MONITOR TRAINING SENSOR ELECTRONICS CORPORATION

Sitron s CF Line of Flow Switch Monitors

LR range (solid door) LR 750 G / GG

Products and performance

Electronic Pressure Digest. Pressure and Temperature Transmitters

U86B. Urea Dosing SPECIFICATIONS FEATURES APPLICATIONS

DP86 Constant Voltage with Fitting

Figure 1 TWM1000 Electromagnetic Flow Converter. 1. Large, illuminated graphic display with intuitive operation 2. For AC and DC operation

86 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

Transmitter Series. Intelligent Transmitter Series Tailor the Measurement to Your Needs INGOLD

Dimensions. Electrical connection. Model Number. Features. Indicators/operating means. Product information RAVE-D-NA. Radar sensor

89BSD Digital Output

Scanning Laser Range Finder Smart-URG mini UST-10LN Specification

GMA 301. Operation Manual. Worldwide Supplier of Safety Solutions. Part Number

La Marche Manufacturing Company Option 46 Series. Digital Combined Accessory Package. Installation and Operation Manual

Process Alarm Module RTA 421

Rosemount 3051CFP Integral Orifice Flowmeter

Transmitter for O 2 ZD21. Operation Manual

MODEL 4000A & 4001A ACCELEROMETER

Druck DPI 705/DPI 705 IS Series

85 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

SHAKING WATER BATHS ENGLISH

METAL SHARK COMBI Flat metal detector for textile and non-woven products. Metal sensitivity from Fe 0,3 mm

ULTRA HIGH EFFICIENCY CONDENSING BOILERS MILLION BTU/HR

Multi-Gas-Controller MGC2

E²M. Innovation with Integrity. Enhanced Environmental Mass Spectrometer. Safety & Security

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

EC3-X33 Stand-alone Superheat Controller Technical Data

Frequently asked questions: Intelligent Transmitter Series

Leading Safety Standards Superior Ease of Use Reduced Cost of Ownership. Intelligent. Evaporation

MS4525 SPECIFICATIONS

SSC Series Standard Accuracy Plastic Silicon Pressure Sensors ±2 % Total Error Band, Digital Output, SMT and DIP, 1 psi to 150 psi

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel

Danfoss gas detection units

GMA4100-DP. Control Panel. Operation Manual. Worldwide Supplier of Gas Detection Solutions

Rosemount 3051CFC Compact Flowmeter

SITRANS T temperature transmitters A broad product family for every application. sitrans

Boilers Variable Fire Boilers

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010 Rev.

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...

Dependable Solutions for Gas Detection

Thermal mass fl owmeter Precise and dynamic gas measurement with Sensyfl ow

82 Constant Voltage SPECIFICATIONS. 316L SS Pressure Sensor 19mm Diameter Package 0-100mV Output Absolute and Gage Temperature Compensated

Using the DewTrak II Dew Point/ Humidity Transmitter

Specification , July 2015

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

Model D12-IR. Digital Gas Transmitter...

APPLICATION DATA SHEET

Dimensions. Model Number. Electrical connection. Features. Product information. Indicators/operating means RMS-G-RC. Radar sensor

PowerRouter application guideline

F-1100 Series Single Turbine Meters Suitable for pipe sizes 1 ¼ and larger.

RPS/DPS High Accuracy Resonant Pressure Sensor. GE Measurement & Control. Features:

AQ3000 W6560C1005 HEAT/COOL OTC UNDERFLOOR CONTROLLER INSTALLATION INSTRUCTIONS CONTENTS REVISION OVERVIEW... 2 GENERAL... 3 MOUNTING...

Key-Operated Switch GMA 41 / GMA 44 SW. Operation Manual

GM420. Digital Ground Continuity Relay For AC Systems. Technical Bulletin NAE /

FCCP 200: Fume-cupboard indicator and monitor

Oxygen (O2) Single-Point Gas Detection System

RIELLO ARRAY. High Efficiency Condensing Boiler MBH.

Touchpoint Pro Flexible Gas Control System

Sub psi SPECIFICATIONS

VAV Thermostat Controller Specification and Installation Instructions. Model TRO24T4XYZ1

intelligent solutions

M7100 Pressure Transducer

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Beam-A-Temp Portable Infrared Thermometer Measures up to 1832 F/1000 C with 50:1 distance to target ratio. Specifications

EST User Manual. (Please read this manual carefully before using)

85 Uncompensated SPECIFICATIONS FEATURES APPLICATIONS STANDARD RANGES. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage

Interactive Catalog Replaces Catalog Pages

Complete Boiler Management in a Compact, Affordable System

PTWS 120D USP/EP Tablet Dissolution Testing Instrument

Model A-5. Low Range Wet/Wet Differential Pressure Transducer DESCRIPTION FEATURES

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

86 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

Zareba Unipoint controller

86A SPECIFICATIONS. 316L SS Pressure Sensor Small Profile V High Level Output Gage, Absolute ASIC Calibrated

TPOne-B. Electronic Programmable Room Thermostat. Installation Guide. Danfoss Heating

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems

SECTION Fluorescent Dissolved Oxygen Measuring System

Leading Safety Standards Superior Ease of Use Reduced Cost of Ownership. Intelligent. Evaporation

LINETRAXX VME420. Multi-functional relay for overvoltage, undervoltage and frequency monitoring in AC/DC systems with external supply voltage

Transcription:

Next Generation red-y compact: AA Battery Powered Touch Technology Micro-UB Port Alarm Option red-y compact 2 series product information Battery Powered Digital Mass Flow Meters for Gases

Independent digital convenience: Thermal Mass Flow Meters for Gases The red-y compact 2 series mass flow meters are characterized by powerful technology, intelligent functions and innovative design. This latest generation offers a new level of ease of use: compact design with battery power and backlit touch display for great flexibility. Touch Technology The touch display offers intuitive navigation. The many variables that make the unit flexible are easily accessible Independent Operation The flow meters are powered with standard AA battery and Micro-UB power supply. Optional 24 Vdc power supply available Modular Extensions The instruments can be extended and retrofitted with different modules: battery module, power module and alarm module High Accuracy & Dynamics The devices offer high accuracy & a wide dynamic range: Accuracy up to ±1% of full scale Turndown ratio up to 1 : 100 (depending on application/measuring range) Totalizer In addition to the actual 4674 flow, the total consumption is displayed. Ideal for gas 4674 consumption measurements Instrument versions "red-y compact 2 series" Version Touch Display Power supply compact meter GCM compact regulator GCR compact switch GC compact all-in GCA Choose between multiple home screens tandard Totalizer Multigas (up to 3) Manual valve Alarm functions Option Mirco-UB power supply Battery power 24 Vdc supply 1 Device Multiple Gases One measuring device can be used for up to 3 different gases or gas mixtures Password Protection To avoid unauthorized change of settings, the menu of the new red-y compact can be locked with a password 3-Year Warranty* High-quality components ensure long and trouble-free operation *does not apply to calibration, battery, options and accessories

The new red-y compact 2 series Even more stunning features: Wide Choice of Flow Units: Choose between a large number of standardized and normalized flow units of the Imperial, U customary and I measuring systems (with user adjustable reference conditions). The units are selectable from the integrated menu both for the actual flow and the totalized flow Extended Alarm Functions: The red-y compact 2 series provides 3 configurable alarms. The following triggers are available: Low alarm, high alarm, window alarm and totalizer alarm The alarms can be configured with different parameters: Normally open, normally closed, hysteresis, auto/manual/remote reset, delay and alarm duration Device Information & Notifications Display of complete device information including all configuration settings. Alerts and notifications show up on the home screen Upgrade Device Features New device features will be available and can be updated through the built-in UB interface. tay informed on latest releases at twitter.com/vogtlinmassflow or www.voegtlin.com VA-Meters vs. Massflow Meters Many applications require a higher accuracy together with pressure and temperature compensation which cannot be realized with conventional variable area flow meters. VA-meters are extremely sensitive to pressure and temperature changes. 1 bar change in pressure can generate an error of 50% in your measurement. Our mass flow meters generate repeatability! The electronic alarm module offers many options over a single VA-meter alarm. Autonomy, precision and comfort for your application Through the application of high-precision MEM technology (CMO sensors), the thermal flow meters and controllers from Vogtlin Massflow UA set new standards in terms of response characteristics and measuring accuracy, and are characterized by maximum convenience: The devices are very compact, can be installed in any position, and are immediately ready for operation The built-in touch display with an intuitive navigation offers various settings The devices measure real mass flow, independent of changes in pressure and temperature. This provides high accuracy and repeatability to the measuring results In addition to the actual value, the total consumption is displayed. This creates transparency in supply systems The autonomous operation with a standard AA battery makes the compact a high-precision alternative to variable area flow meters High quality: All flow meters are produced and calibrated at our headquarters in Aesch, witzerland Our specialists will be happy to advise: +1 262 884 9800 or www.voegtlin.com

Technical data "red-y compact 2 series" Instrument types compact meter GCM Mass Flow Meter compact switch GC Mass Flow Meter with Alarm Functions Measuring ranges compact regulator GCR Mass Flow Meter with manual Valve compact all-in GCA Mass Flow Meter with Alarm Functions & Valve (full scale freely selectable) Type Measuring range (air) Performance data Media (real gas calibration) compact ½" versions The valve is flange mounted GCX / ¼" from 0... 27 CCM to 0... 64 LPM GCX / ½" from 0... 65 LPM to 0... 480 LPM Air, O2*, N2*, He, Ar, CO2, H2, CH4, C3H8 (other gases and gas mixtures on request) *O2 & N2 are calibrated with air Accuracy (air & equivalents) Eco: ± 2.0% of full scale; ranges > 200 LPM ± 3.0% of full scale pecial: ± 1.0% of full scale up to 50 LPM Turndown ratio Eco: 1 : 50 pecial: 1 : 100 Response time Max. 300 msec (depending on filter settings) Flow update by sensor 40 msec (battery mode 500 msec) Display update 240 msec (battery mode 500 msec) Repeatability ± 0.5% of full scale Longterm stability < 1% of measured value / year Power supply Meter & Regulator tandard AA battery (lifetime in months depending on operation) or Micro-UB power supply (DIN 62684) Option: External power +12...30 Vdc (power consumption max. 100mA) Power supply witch & All-in Operation pressure Temperature (environment/gas) Materials eals External power +12...30 Vdc (power consumption max. 200mA) or Micro-UB power supply (DIN 62684) 3-160 psia (0.2-11 bara) 32-122 F (0 50 C) Anodized aluminum, optional stainless steel electropolished FM, optional EPDM (FDA) Pressure sensitivity <0.014% / psi (<0.2% / bar) of reading (typical N2) Temperature sensitivity Warm-up time Integration Display Process connection Inlet section <0.012% F measuring range type per 1 F (<0.025% per 1 C) < 1 sec. for full accuracy Touch display 128x64 px Backlighted only with external power supply (Micro-UB or 24 Vdc) G¼" (BPP* female) up to 64 LPM, G½" (BPP* female) up to 480 LPM *British tandard Pipe Parallel None required Mounting orientation Any position (consult manufacturer above 73 psi / 5 bar or vertical mounting) / Display rotates 180 Connection cable For external power supply: 6.5 ft with fly leads afety Test pressure 240 psia (16 bara) Leak rate < 1 x 10-6 mbar l/s He Environmental protection IP50 (conforms to NEMA 1) EMC EN 61326-1 Options Panel Mounting it Vacuum Fittings Various Inlet and Outlet Fittings

Type code "red-y compact 2 series" Instrument type red-y compact 2 series (Gas) G C Function Meter M Regulator With manual valve R witch With alarm All-In With manual valve & alarm A Full scale of measuring range (Air) Divider A, up to 640 CCM, ¼" Body A X defined by manufacturer Divider B, up to 6,400 CCM, ¼" Body B X Divider C, up to 64 LPM, ¼" Body C X Divider D, up to 480 LPM, ½" Body D X Instrument version Eco (±2.0% of F / > 200 LPM ±3.0% of F, 1 : 50) E pecial (±1.0% of F, 1 : 100 / up to 50 LPM) Materials (Body, seals) Aluminum, FM A Aluminum, EPDM B tainless steel, FM tainless steel, EPDM T upply (Micro-UB always available) Battery supply B External supply 24 Vdc, 6.5 ft F Material valve (regulator, all-in) Nickel-plated brass A tainless steel No valve N Manual valve N 1.0 1 0 defined by manufacturer N 1.5 1 5 N 2.0 2 0 N 2.5 2 5 N 3.0 3 0 N 3.5 3 5 N 4.0 4 0 N 6.0 6 5 Valve not defined 8 8 Valve mounted 9 5 9 9 No valve 0 0 Type code G C Dimensions "red-y compact 2 series" 3.5 Length (inch) Length of fitting Type / Body A B C D P 0.73 1.04* * only valve units (GCR+GCA) GCM ¼" GCR ¼" GC ¼" GCA ¼" GCM ½" GC ½" GCR ½" GCA ½" 4.49 1.73 0.98 1.73 6.3 2.13 1.38 2.13 8.15 2.13 1.38 2.13 We offer a range of different inlet/outlet fittings. ee document 329-2092_en_ fittings.pdf for types and dimensions C D Micro-UB Interface (DIN 62684)

Worldwide Flow Network Vögtlin ales & ervice Hub North America: International Headquarter: Vögtlin ales & ervice Hub China: AW-Lake Company 2440 W. Corporate Preserve Dr. #600 Oak Creek, WI 53154, UA Phone +1 262-884-9800 Fax +1 262-884-9810 info@aw-lake.com www.aw-lake.com Vögtlin Instruments AG Langenhagstrasse 1 4147 Aesch BL, witzerland Phone +41 61 756 63 00 Fax +41 61 756 63 01 info@voegtlin.com www.voegtlin.com EM flow technology (Beijing) Co., Ltd. Rm. 906, Block C, Ruipu Office Bldg, No. 15, HongJunYingNan Road, Chaoyang District, Beijing 100012, China Phone +86 10 849 29567 info@kem-kueppers.cn www.voegtlin.cn Find your local Vogtlin sales partner on our website: www.voegtlin.com Vögtlin Instruments AG flow technology Langenhagstrasse 1 4147 Aesch (witzerland) Phone +41 (0)61 756 63 00 Fax +41 (0)61 756 63 01 www.voegtlin.com info@voegtlin.com 2016 Vogtlin Instruments AG witzerland subject to technical change 329_2088_en_compactus V160808