TABLE OF CONTENTS ERHQ BAV3

Similar documents
TABLE OF CONTENTS ERSQ-AAY1

EEDEN technical data ERHQ AA. Altherma. Altherma

EEDEN technical data ERHQ AA

TABLE OF CONTENTS RMXS-E8V1B

technical data air conditioning systems RMXS-E7V3B1 Super multi plus Split Sky Air

Heating. Technical Data. Daikin Altherma low temperature split EEDEN ERLQ-CW1

EEDE06-9. technical data. Altherma ERYQ A EKHBH007A / EKHBX007A EKSWW

EEDEN technical data. air conditioning systems RZQS-DV1. Split Sky Air

TABLE OF CONTENTS EBLQ01-016AA6V3

technical data air conditioning systems RZQ B8W1B Split Sky Air

EEDEN technical data. air conditioning systems RZQ-DV1. Split Sky Air

TABLE OF CONTENTS EDLQ AA6V3

EEDEN technical data. air conditioning systems RZQS71-140C7V1B. Split Sky Air

1 Features. Outdoor Units R-410A RYN-E3V1B. Split Sky Air Outdoor Units

technical data air conditioning systems Indoor Units FBQ-C7VEB

Air Conditioning Technical Data RZASG-MV1

Air Conditioners. Technical Data FBQ-C

Air Conditioning Technical Data RZAG-MV1

Heating. Technical Data. Daikin Altherma low temperature monobloc EEDEN EBLQ-BB6W1

Heating. Technical Data. Daikin Altherma low temperature monobloc EEDEN EDHQ-BB6V3

EEDEN technical data. Altherma ERHQ AD EKHBH/X008AA ERHQ AA EKHBH/X016AB EKHWS(U) EKSOL

EEDEN technical data. Altherma ERHQ AA EKHBH007AC / EKHBX007AC EKSWW

EEDEN technical data. Altherma ERHQ AD EKHBH/X008AA ERHQ AA EKHBH/X016AB EKHWS(U) EKSOL

technical data air conditioning systems RZQ-B Pair/Twin/Triple/Double Twin Application, Inverter Controlled Unit Split Sky Air

technical data air conditioning systems RZQ-B9V3B_RZQ-B8W1B Pair, Twin, Triple, Double Twin, Application, Inverter Controlled Split Sky Air

Air Conditioners. Technical Data. Heating only hydrobox for VR V HXHD-A

technical data air conditioning systems RR-B8V3B_RR-B8W1B Pair, Twin, Triple Application Split Sky Air

Air Conditioning. Technical Data EEDEN AZQS-BV1

EEDEN technical data. Altherma TM

Air Conditioning Technical Data AZAS-MY1

EDUS Heat Pump - D-Series

technical data air conditioning systems RZQ C7Y1B Split Sky Air

General Outline: Altherma

DESIGN MANUAL Version 1.0

Service Manual. Air Cooled Refrigeration Condensing Unit

DACA-EEDEN technical data. Engineering Data. DaikinAltherma

technical data air conditioning systems FDKS-CVMB Concealed ceiling, Inverter Controlled Unit Split Sky Air

Air Conditioning. Technical Data. VRV IV heat recovery EEDEN14-200_4 REYQ-T

Heating. Technical Data EEDEN ERRQ-AY1

technical data air conditioning systems FDXS-CVMB Concealed Ceiling, Inverter Controlled Unit Split Sky Air

technical data air conditioning systems FHYCP-B7 4-way Blow Ceiling Mounted Cassette (950x950) Split Sky Air

Heating Nom. dba 50 (5) 50 (5) 50 (5) Cooling Nom. dba 50 (5) 50 (5) 50 (5) Anti freeze heater (optional) W Expansion vessel Volume l 6 6 6

EDUS D Engineering Data RXYQ-TAYCU, 575 V. Heat Pump 60 Hz

Air Conditioning. Technical Data EEDEN RZQSG-L(3/8)V1

technical data air conditioning systems FHYP-B Ceiling Suspended Unit Split Sky Air

technical data air conditioning systems FHYKP-B Ceiling Mounted Corner Cassette Split Sky Air

Air Conditioning. Technical Data EEDEN RZQG-L8/7V1

technical data air conditioning systems FTXG-C Wall Mounted, Inverter Controlled Unit Split Sky Air

technical data air conditioning systems Indoor Units FCQ-C8VEB

Air Conditioning. Technical Data. Multi model application EEDEN MXS-E

Air Conditioners. Technical Data RZQG-L

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

Air Conditioning. Technical Data. Pair, Twin, triple, double twin EEDEN RZQ-C

Digital Inverter 4 series 8 & 10HP

Air Conditioning. Technical Data. High temperature hydrobox for VRV EEDEN HXHD-A8

technical data air conditioning systems FVXS-FV1B R-410A Split Sky Air

Air Conditioning. Technical Data EEDEN RZQSG-L(8)Y1

SERVICE MANUAL MUFZ-KJ50VE - E1, E2, ER1, ER2, ET1, ET2 MUFZ-KJ35VE OUTDOOR UNIT. No. OBH667. Models HFC

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624 REVISED EDITION-E. Models HFC

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624. Models HFC. Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624.

technical data air conditioning systems FT(Y)S-B Wall Mounted Unit Split Sky Air

PUHZ-SHW140YHA PUHZ-SHW230YKA

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

technical data air conditioning systems FH(Y)B-FK7 Concealed Ceiling Unit Split Sky Air

PURY-P200YMF-C, PURY-P250YMF-C CONTENTS

Chillers. Technical Data. Air Cooled Chiller ECDEN10-403A EUWA*-KBZW1 EUWY*-KBZW1

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

MUH-24RV - MSH-30RV -

TECHNICAL DATA & SERVICE MANUAL

Air Conditioners. Technical Data FTXS-G

PMFY-P-VBM-E. Ceiling cassette (1-way flow type) R410A Data G8 1. SPECIFICATIONS EXTERNAL DIMENSIONS CENTER OF GRAVITY 1-100

DESIGN & TECHNICAL MANUAL

technical data air conditioning systems FTKS/FTXS-C FTKS/FTXS-B Wall Mounted, Inverter Controlled Unit Split Sky Air

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

SERVICE MANUAL MUZ-SF25VE MUZ-SF25VEH MUZ-SF35VE MUZ-SF35VEH MUZ-SF42VE MUZ-SF42VEH MUZ-SF50VE MUZ-SF50VEH OUTDOOR UNIT. No. OBH629 REVISED EDITION-E

3.2 E1 Outdoor Unit PCB Abnormality E4 Actuation of Low Pressure Sensor E5 Compressor Motor Lock 3 52

TABLE OF CONTENTS EKHWS

SERVICE MANUAL MUZ-EF25VE MUZ-EF25VEH MUZ-EF35VE MUZ-EF35VEH MUZ-EF42VE MUZ-EF50VE. No. OBH590 REVISED EDITION-F. Models HFC

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

TECHNICAL & SERVICE MANUAL. Ceiling Concealed

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

SERVICE MANUAL OUTDOOR UNIT. No. OBH629 REVISED EDITION-A. Models HFC. Revision A: MUZ-SF25/35/42VE - E2 have been added. Please void OBH629.

DESIGN & TECHNICAL MANUAL

SERVICE MANUAL OUTDOOR UNIT. No. OBH530. Models MU-GE50VB- E1 MUH-GE50VB- E1 HFC SPLIT-TYPE AIR CONDITIONERS R410A

DESIGN & TECHNICAL MANUAL

Air Conditioning. Technical Data. VRV IV S-series compact heat pump EEDEN RXYSCQ-TV1

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

SERVICE MANUAL MUZ-HC25VA - E1 MUZ-HC35VA - E1 MUZ-HC35VA - E2 MUZ-HC35VAB - E1 MUZ-HC35VAB - E2 OUTDOOR UNIT. No. OBH467.

SERVICE MANUAL MXZ-2A40VA - MXZ-2A52VA - MXZ-3A54VA - MXZ-3A54VA - MXZ-4A71VA - MXZ-4A71VA - MXZ-4A80VA - E1 OUTDOOR UNIT. No. OB377 REVISED EDITION-A

EEDEN technical data EKSOLHWAV1

TECHNICAL DATA & SERVICE MANUAL DISEGNO MACCHINA

SERVICE MANUAL MXZ-A18WV - MXZ-A26WV - MXZ-A32WV - E1 HFC. Inverter-controlled multi system Models SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS. No.

Air Conditioning. Technical Data EEDEN RXS-F8

SERVICE MANUAL MUZ-GE50VA - E1 MUZ-GE50VAH - E1 MUZ-GE60VA - E1 MUZ-GE71VA - E1

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

AIR-CONDITIONER TOSHIBA SERVICE MANUAL SPLIT TYPE, HEAT PUMP COOLING ONLY FILE NO. A Tel: Fax:

Transcription:

TABLE OF CONTENTS ERHQ006-016BAV3 1 Features........................................................... 134 2 Specifications..................................................... 135 Nominal Capacity and Nominal Input............................. 135 Technical Specifications........................................... 135 Electrical Specifications........................................... 138 3 Capacity tables................................................... 140 Cooling capacity tables............................................ 140 Heating capacity tables............................................ 141 Cooling/Heating capacity tables................................... 143 4 Dimensional drawing & centre of gravity...................... 144 Dimensional drawing............................................... 144 Centre of gravity................................................... 145 5 Piping diagram.................................................... 146 6 Wiring diagram.................................................... 147 Wiring diagram..................................................... 147 7 Sound data........................................................ 148 Sound pressure spectrum.......................................... 148 Sound pressure spectrum quiet mode............................. 150 8 Installation......................................................... 152 Installation method................................................. 152 Operation range.................................................. 154 Heating Daikin Altherma 133

2 Specifications 2-1 NOMINAL CAPACITY AND NOMINAL INPUT ERHQ011BAV3 ERHQ014BAV3 ERHQ016BAV3 ERHQ006BAV3 ERHQ007BAV3 ERHQ008BAV3 For combination indoor units + outdoor units Indoor Units EKHBH016BA EKHBH016BA EKHBH016BA EKHBH008BA EKHBH008BA EKHBH008BA Condition 1 Heating capacity Minimum kw 4.36 4.36 4.36 Nominal kw 11.2 14.0 16.0 5.75 6.84 8.43 Maximum kw 7.45 8.7.58 Heating PI Nominal kw 2.46 3.17 3.83 1.26 1.58 2.08 COP Nominal 4.55 4.42 4.18 4.56 4.34 4.05 Nominal Capacity Heating capacity Minimum kw 3.87 3.87 3.87 For combination indoor units + outdoor units Nominal kw 10.3 13.1 15.2 5.03 6.10 7.64 Maximum kw 6.68 7.8 8.76 Heating PI Nominal kw 3.06 3.88 4.66 1.58 1.5 2.54 COP Nominal 3.37 3.38 3.26 3.18 3.13 3.00 Indoor Units EKHBX016BA EKHBX016BA EKHBX016BA EKHBX008BA EKHBX008BA EKHBX008BA Condition 1 Heating capacity Minimum kw 4.36 4.36 4.36 Nominal kw 11.2 14.0 16.0 5.75 6.84 8.43 Maximum kw 7.45 8.7.58 Cooling capacity Minimum kw 4.82 4.82 4.82 Nominal kw 13. 17.3 17.8 7.20 8.16 8.37 Maximum kw 7.20 8.50 8.1 Heating PI Nominal kw 2.46 3.17 3.83 1.26 1.58 2.08 Cooling PI Nominal kw 3.7 5.78 6.77 2.27 2.78 2.7 COP Nominal 4.55 4.42 4.18 4.56 4.34 4.05 EER Nominal 3.67 2. 2.63 3.17 2.4 2.82 Nominal Capacity Heating capacity Minimum kw 3.87 3.87 3.87 Nominal kw 10.3 13.1 15.2 5.03 6.10 7.64 Maximum kw 6.68 7.8 8.76 Cooling capacity Minimum kw 3.67 3.67 3.67 Nominal kw 10.0 12.5 13.1 5.12 5.86 6.08 Maximum kw 5.12 6.13 7.10 Heating PI Nominal kw 3.06 3.88 4.66 1.58 1.5 2.54 Cooling PI Nominal kw 3.60 5.2 5.5 2.16 2.5 2.75 COP Nominal 3.37 3.38 3.26 3.18 3.13 3.00 EER Nominal 2.78 2.36 2.20 2.37 2.26 2.21 Notes Condition 1: cooling Ta 35 C - LWE 18 C - heating Ta DB/WB 7 C/6 C - LWC 35 C ( DT = 5 C ) Condition 1: cooling Ta 35 C - LWE 18 C - heating Ta DB/WB 7 C/6 C - LWC 35 C ( DT = 5 C ) Condition 1: cooling Ta 35 C - LWE 18 C - heating Ta DB/WB 7 C/6 C - LWC 35 C ( DT = 5 C ) Condition 1: cooling Ta 35 C - LWE 18 C (DT = 5 C) - heating Ta DB/WB 7 C/6 C - LWC 35 C (DT = 5 C) Condition 1: cooling Ta 35 C - LWE 18 C (DT = 5 C) - heating Ta DB/WB 7 C/6 C - LWC 35 C (DT = 5 C) Condition 1: cooling Ta 35 C - LWE 18 C (DT = 5 C) - heating Ta DB/WB 7 C/6 C - LWC 35 C (DT = 5 C) Condition 2: cooling Ta 35 C - LWE 7 C ( DT = 5 C ) - heating Ta DB/WB 7 C/6 C - LWC 45 C ( DT = 5 C ) 2 2-2 TECHNICAL SPECIFICATIONS ERHQ011BAV3 ERHQ014BAV3 ERHQ016BAV3 ERHQ006BAV3 ERHQ007BAV3 ERHQ008BAV3 Casing Colour Ivory white Material Painted galvanised steel plate Painted galvanised steel plate Painted galvanised steel plate Polyester painted galvanised steel Polyester painted galvanised steel Dimensions Unit Height mm 1,170 1,170 1,170 735 735 735 Polyester painted galvanised steel Width mm 00 00 00 825 825 825 Depth mm 320 320 320 300 300 300 Packing Height mm 1,34 1,34 1,34 77 77 77 Width mm 80 80 80 60 60 60 Depth mm 420 420 420 30 30 30 Heating Daikin Altherma 135

2 Specifications 2 2-2 TECHNICAL SPECIFICATIONS ERHQ011BAV3 ERHQ014BAV3 ERHQ016BAV3 ERHQ006BAV3 ERHQ007BAV3 ERHQ008BAV3 Weight Unit kg 103 103 103 57 57 57 Packed Unit kg 114 114 114 62 62 62 Packing Material EPS Wood Wood Wood PE (Straps) PE (Straps) PE (Straps) Weight kg 11 11 11 5 5 5 Heat Exchanger Dimensions Length mm 857 857 857 845 845 845 Carton Nr of Rows 2 2 2 2 2 2 Fin Pitch mm 1.4 1.4 1.4 1.8 1.8 1.8 Nr of Passes 6 6 6 Face Area m² 0.8 0.8 0.8 Nr of Stages 52 52 52 32 32 32 Tube type Hi-XSS(8) Hi-XSS(8) Hi-XSS(8) Hi-Xa(8) Hi-Xa(8) Hi-Xa(8) Fin Type WF fin Treatment Anti-corrosion treatment (PE) Fan Type Propeller Air Flow Rate (nominal at 230V) Quantity 2 2 2 1 1 1 Heating High m³/min 0 0 0 Cooling High m³/min 6 100 7 Fan Discharge direction Horizontal Motor Quantity 2 2 2 1 1 1 Model Brushless DC motor Brushless DC motor Brushless DC motor Output W 53 53 53 Motor Speed (nominal) Steps 8 8 8 Heating rpm 760 760 760 Cooling rpm 800 850 830 Fan Motor Output W 70 70 70 Drive Direct drive Direct drive Direct drive Compressor Quantity 1 1 1 1 1 1 Motor Model JT100G-VD JT100G-VD JT100G-VD 2YC63BXD#C 2YC63BXD#C 2YC63BXD#C Type Hermetically sealed scroll compressor Hermetically sealed scroll compressor Hermetically sealed scroll compressor Hermetically sealed swing compressor Hermetically sealed swing compressor Hermetically sealed swing compressor Motor Output W 2,200 2,200 2,200 1,20 1,20 1,20 Starting Method Inverter driven Inverter driven Inverter driven Motor Crankcase Heater Output W 33 33 33 Operation Range Heating Min CWB -20-20 -20-20 -20-20 Max CWB 35 35 35 25 25 25 Cooling Min CDB 10 10 10 10 10 10 Max CDB 46 46 46 43 43 43 Sanitary water Min CDB -20-20 -20-20 -20-20 Max CDB 43 43 43 43 43 43 Sound Level (nominal) Heating Sound Power dba 64 64 66 61 61 62 Sound Level (Night quiet) Sound Pressure dba 4 51 53 48 48 4 Cooling Sound Power dba 64 66 6 63 63 63 Sound Pressure dba 50 52 54 48 48 50 Heating Sound Pressure dba 42 42 43 Cooling Sound Pressure dba 45 45 46 Refrigerant Type R-410A Charge kg 3.7 3.7 3.7 1.7 1.7 1.7 Control Expansion valve(electronic type) Nr of Circuits 1 1 1 1 1 1 Refrigerant Oil Type Daphne FVC68D Daphne FVC68D Daphne FVC68D FVC50K FVC50K FVC50K Charged Volume l 1.0 1.0 1.0 0.75 0.75 0.75 136 Heating Daikin Altherma

2 Specifications 2-2 TECHNICAL SPECIFICATIONS ERHQ011BAV3 ERHQ014BAV3 ERHQ016BAV3 ERHQ006BAV3 ERHQ007BAV3 ERHQ008BAV3 Piping connections Liquid (OD) Quantity 1 1 1 Defrost Method Defrost Control Capacity Control Method Safety Devices Type Flare connection Diameter (OD) mm,52,52,52 6,35 6,35 6,35 Gas Quantity 1 1 1 Type Flare connection Diameter (OD) mm 15, Drain Quantity 3 3 3 1 1 1 Type Hole Hole Hole Socket Socket Socket Diameter (OD) mm 26 26 26 18 18 18 Piping Length Minimum m 5 5 5 3 3 3 Maximum m 75 75 75 30 30 30 Equivalent m 5 5 5 Chargeless m 30 30 30 Additional Refrigerant Charge kg/m See installation outdoor unit 4PW3776-1B Installation height difference See installation outdoor unit 4PW3776-1B See installation outdoor unit 4PW3776-1B Maximum m 30 30 30 0.02>10m 0.02>10m 0.02>10m Max. internunit level difference m 20 20 20 Heat Insulation Both liquid and gas pipes Pressure equalising Fan motor thermal protector Both liquid and gas pipes Pressure equalising Fan motor thermal protector Both liquid and gas pipes Pressure equalising Sensor for outdoor heat exchanger temperature Inverter controlled Fan motor thermal protector Fuse Fuse Fuse High pressure switch High pressure switch High pressure switch Reverse cycle Reverse cycle Reverse cycle 2 Heating Daikin Altherma 137

2 Specifications 2 2-2 TECHNICAL SPECIFICATIONS ERHQ011BAV3 ERHQ014BAV3 ERHQ016BAV3 ERHQ006BAV3 ERHQ007BAV3 ERHQ008BAV3 Standard Accessories Item Tie-wraps Tie-wraps Tie-wraps Installation Notes Installation Quantity 2 2 2 1 1 1 Item Installation Installation Installation Installation Drain plug Drain plug Drain plug Quantity 1 1 1 1 1 1 The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. Down to 3m with recharging of the outdoor unit. Refer to the installation of the outdoor unit. The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. Down to 3m with recharging of the outdoor unit. Refer to the installation of the outdoor unit. The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. Down to 3m with recharging of the outdoor unit. Refer to the installation of the outdoor unit. See operation range drawing The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. See operation range drawing The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. See operation range drawing The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. 2-3 ELECTRICAL SPECIFICATIONS ERHQ011BAV3 ERHQ014BAV3 ERHQ016BAV3 ERHQ006BAV3 ERHQ007BAV3 ERHQ008BAV3 Power Supply Name V3 Phase 1~ Frequency Hz 50 50 50 50 50 50 Voltage V 230 230 230 230 230 230 Voltage range Minimum V -10% Maximum V +10% 138 Heating Daikin Altherma

2 Specifications 2-3 ELECTRICAL SPECIFICATIONS ERHQ011BAV3 ERHQ014BAV3 ERHQ016BAV3 ERHQ006BAV3 ERHQ007BAV3 ERHQ008BAV3 Current Minimum Ssc value kva Equipment complying with EN/IEC 61000-3-12: European/ International Technical Standard setting the limits for harmonic currents produced by equipment connected to public lowvoltage systems with input current >16A and <=75A per phase Equipment complying with EN/IEC 61000-3-12: European/ International Technical Standard setting the limits for harmonic currents produced by equipment connected to public lowvoltage systems with input current >16A and <=75A per phase Equipment complying with EN/IEC 61000-3-12: European/ International Technical Standard setting the limits for harmonic currents produced by equipment connected to public lowvoltage systems with input current >16A and <=75A per phase Equipment complying with EN/IEC 61000- S-12 (1) Equipment complying with EN/IEC 61000- S-12 (1) Equipment complying with EN/IEC 61000- S-12 (1) Starting current Heating A 11 11 11 Maximum running Current Cooling A 11 11 11 Heating A 18 18 18 Cooling A 22.8 27.4 31. 16.25 16.25 16.25 Recomended fuses A 32 32 32 20 20 20 Wiring connections For Power Supply Quantity 3 3 3 Power Supply Intake Notes For connection with indoor Remark See installation outdoor unit 4PW3776-1B See installation outdoor unit 4PW3776-1B See installation outdoor unit 4PW3776-1B Quantity 4 4 4 Remark See installation outdoor unit 4PW3776-1B Outdoor unit only See installation outdoor unit 4PW3776-1B Outdoor unit only See installation outdoor unit 4PW3776-1B Outdoor unit only Included earth wiring (1) European/ international technical standard setting the limits for harmonic currents produced by equipment connected to public lowvoltage system with input current > 16A smaller than or equal to 75A per phase. Included earth wiring (1) European/ international technical standard setting the limits for harmonic currents produced by equipment connected to public lowvoltage system with input current > 16A smaller than or equal to 75A per phase. Included earth wiring (1) European/ international technical standard setting the limits for harmonic currents produced by equipment connected to public lowvoltage system with input current > 16A smaller than or equal to 75A per phase. 2 Heating Daikin Altherma 13

3 Capacity tables 3-1 Cooling capacity tables ERHQ011-016BAV3 Maximum Cooling Capacity Model Tamb 20 25 30 35 40 45 LWE [ C] CC [kw] PI [kw] CC [kw] PI [kw] CC [kw] PI [kw] CC [kw] PI [kw] CC [kw] PI [kw] CC [kw] PI [kw] 3TW57752-1C 3 CC HC PI LWE LWC Tamb SYMBOLS : Cooling capacity at maximum operating frequency, measured acc. Eurovent 6/C/003-2006 (kw) : Heating capacity at maximum operating frequency, measured acc. Eurovent 6/C/003-2006 (kw) : Power input (kw), measured acc. Eurovent 6/C/003-2006 (kw) : Leaving Water Evaporator temperature ( C) : Leaving Water Condensor temperature ( C) : Ambient temperature ( C) RH=85% NOTES 1 Cooling capacity Capacity is according to Eurovent rating standard 6/C/003-2006 and valid for chilled water range Dt = 3 8 C Capacity values may not be extrapolated below 7 C leaving water temperature 2 Heating capacity Capacity is according to Eurovent rating standard 6/C/003-2006 and valid for chilled water range Dt = 3 8 C 3 Power input Power input is total of indoor and outdoor unit, except the circulation pump; according to Eurovent rating standard 6/C/003-2006. Pump power input to be added = 0 W (according EN14511). For ERHQ011-16AAW1 models only: if Tamb < 4 C: bottom plate heater power input to be added = 5 W Notes: - For the model with heatertape (*RLQ): when ambiernt temperature becomes lower than [F-02] (default = 3 C) bottom plate heater power input to be added = 5W - [F-02] = BPH ON temp for more details see installation of indoor unit. 140 Heating Daikin Altherma

3 Capacity tables 3-2 Heating capacity tables ERHQ011-016BAV3 Maximum Heating Capacity (Peak values) Model LWC [ C] 30 35 40 45 50 55 Tamb HC [kw] PI [kw] HC [kw] PI [kw] HC [kw] PI [kw] HC [kw] PI [kw] HC [kw] PI [kw] HC [kw] PI [kw] Maximum Heating Capacity (integrated values) Model LWC 30 35 40 45 50 55 Tamb HC PI HC PI HC PI HC PI HC PI HC PI 3 CC HC PI LWE LWC Tamb SYMBOLS : Cooling capacity at maximum operating frequency, measured acc. Eurovent 6/C/003-2006 (kw) : Heating capacity at maximum operating frequency, measured acc. Eurovent 6/C/003-2006 (kw) : Power input (kw), measured acc. Eurovent 6/C/003-2006 (kw) : Leaving Water Evaporator temperature ( C) : Leaving Water Condensor temperature ( C) : Ambient temperature ( C) RH=85% Conditions 3TW57752-1C 1 Cooling capacity Capacity is according to Eurovent rating standard 6/C/003-2006 and valid for chilled water range Dt = 3 8 C Capacity values may not be extrapolated below 7 C leaving water temperature 2 Heating capacity Capacity is according to Eurovent rating standard 6/C/003-2006 and valid for chilled water range Dt = 3 8 C 3 Power input Power input is total of indoor and outdoor unit, except the circulation pump; according to Eurovent rating standard 6/C/003-2006. Pump power input to be added = 0 W (according EN14511). For ERHQ011-16AAW1 models only: if Tamb < 4 C: bottom plate heater power input to be added = 5 W Notes: - For the model with heatertape (*RLQ): when ambiernt temperature becomes lower than [F-02] (default = 3 C) bottom plate heater power input to be added = 5W - [F-02] = BPH ON temp for more details see installation of indoor unit. Heating Daikin Altherma 141

3 Capacity tables 3-2 Heating capacity tables ERHQ011-016BV3 Capacity in function of field piping length for inverter Capacity (%) Field piping length ( m ) COOLING HEATING 3TW542-1A 3 142 Heating Daikin Altherma

4 Dimensional drawing & centre of gravity 4-1 Dimensional drawing ERHQ006-008BV3 unit (mm) Drain outlet (I.D. J 15. hose for connection) Minimum space for air passage Wall height on air outlet side = less than 1200 In case of removing stop valve cover 4 x holes for anchor bolts (M8 or M10) Brand name label Name plate Wiring inlet Terminal strip with earth terminal Outdoor air temperature thermistor Liquid stop valve (J6.4 CuT) Service port Gas stop valve (J15. CuT) 3D06028 4 ERHQ011-016BV3 Hole for anchor bolt 4-M12 j1 Gas pipe connection J15. flare j2 Liquid pipe connection - J.5 flare j3 Service port (in the unit) j4 Grounding terminal M5 (in switch box) j5 Refrigerant piping intake j6 Power supply wiring intake (knock out hole J34) j7 Control wiring intake (Knock out hole J27) j8 Drain outlet 3TW57764-1B 144 Heating Daikin Altherma

4 Dimensional drawing & centre of gravity 4-2 Centre of gravity ERHQ006-008BV3 The position of foundation bolt 4D042258R ERHQ011-016BV3 4 4TW216-4A Heating Daikin Altherma 145

5 Piping diagram ERHQ006-008BV3 Outdoor unit Heat exchanger Outdoor air temperature thermistor Capillary tube 1 Heat exchanger thermistor Capillary tube 2 Capillary tube 3 Muffler with filter Refrigerant flow Cooling Heating Capillary tube 4 Filter Propeller fan Motor operated valve Filter Four way valve on : heating Muffler with filter Muffler Field piping Muffler Liquid stop valve Field piping Discharge pipe thermistor Compressor Accumulator Gas stop valve with service port 3D052750H ERHQ011-016BV3 5 Filter Electronic expansion valve Filter Heat exchanger 4-way valve Low pressure sensor High pressure switch Field piping J.5 C 1220T-0 Compressor Service port 5/16* Field piping J15. C 1220T-0 Accumulator Indoor unit Stop valve (with service port 5/16 flare) Outdoor unit Heating Cooling Check valve Flare connection Screw connection Flange connection Pinched pipe Spinned pipe 3TW57765-1A 146 Heating Daikin Altherma

6 Wiring diagram 6-1 Wiring diagram ERHQ011-016BV3 Position of compressor terminal Wire entrance Option Wiring dependent on model Indoor El. comp. Assy (Position of elements) Outdoor (Note 4) A1P A2P A3P A4P BS1 BS4 C1 C4 DS1 E1H E1HC F1U, F3U, F4U F6U F7U, F8U H1P 7P (A2P) HAP (A1P) K1R K4R K10R K11R L1R M1C M1F M2F PS Q1DI R1 R2 R1T R2T R3T R4T R5T R6T RC R10T S1NPH S1PH TC V1R V2R, V3R V1T X1M Y1E Y1S Z1C Z3C Z1F Z4F Optional connector X1Y Printed circuit board (Main) Printed circuit board (INV) Printed circuit board (Noise filter) Printed circuit board Push button switch Capacitor DIP switch Bottomplate heater Crankcase heater Fuse (T 6.3A/250V) Fuse (T 5.0A/250V) Fuse (F 1.0A/250V) Light emitting diode (service monitor orange) Prepare, Test --------- Flickering Malfunction Detection -- Light up Light emitting diode (service monitor green) Magnetic relay (Y1S) Magnetic relay (E1HC) Magnetic relay Magnetic relay Reactor Motor (Compressor) Motor (Fan) (upper) Motor (Fan) (lower) Switching power supply Earth leakage circuit breaker Resistor Resistor Thermistor (Air) Thermistor (Discharge) Thermistor (Suction) Thermistor (Heat exchanger) Thermistor (heat exchanger middle) Thermistor (Liquid) Signal receiver circuit Thermistor (Fin) Pressure sensor Pressure switch (High) Signal transmission circuit Power module Diode module IGBT Terminal strip (Power supply) Electronic expansion valve Solenoid valve (4 way valve) Noise filter (ferrity core) Noise filter Connector (Back) (Front) Notes: 1 This wiring diagram only applies to the outdoor unit 2 L: Live N:Neutral g: Field wiring 3 D : Terminal strip F : Connector T : Connection R : Protective earth (screw) : Relay connector p : Noiseless earth G : Terminal 4 Refer to the option, for connecting wiring to x6a. 5 Refer to the Wiring diagram sticker (on back of front plate) on how to use BS1 BS4 and DS1 switch. 6 Do not operate the unit by short-circuiting protection device S1PH 7 Colors: BLK: black, RED: red, BLU: blue, WHT: white, YLW: yellow, ORG: orange, BRN: brown, GRN: green 8 Confirm the method of setting the selector switches by service. When the unit is shipped by factory all switches are set to be off. 2TW5556-1A ERHQ006-008BV3 Power supply 6 To indoor unit Sheet metal Indoor g Field wiring (outdoor) (discharge) (Condenser) Outdoor Z1C Z7C : Ferrite core X1M, X2M : Terminal strip Y1E : Electronic expansion valve coil V2, V3, V5, V, V100 : Varistor SA2 : Surge arrester FU1, FU2, FU3: : Fuse AC1, AC2 U, V, W, X11A, X12A E1, E2 HR1, HR2 : Connector MRM10, MRM20 MRC/W : Magnetic relay R1T R3T : Thermistor S2 S102 : Connector LEDA : Pilot lamp L : Live N : Neutral SW1 : Forced operation on/off switch SW (SW1) SW4 : Local setting SW (SW4) M1C : Compressor motors M1F : Fan motor L1R : Reactor Q1L PM1 PCB1,2 Y1R Sheet metal : Overload protector : Power module : Printed circuit board : Reversing solenoide valve coil : Terminal strip fixed plate 3D05226E Heating Daikin Altherma 147

7 Sound data 7-1 Sound pressure spectrum ERHQ006BV3 COOLING ERHQ007BV3 COOLING ERHQ008BV3 COOLING Octave band center frequency (Hz) Octave band center frequency (Hz) Octave band center frequency (Hz) Notes: 1 Data is valid at free field condition (measured in a semi-anachoic room) 2 dba = A-weighted sound power level (A-scale according to IEC) 3 Reference acoustic pressure 0dB = 20µPa 4 If sound is measured under actual installation conditions, the measured value will be higher due to environmental noise and sound reflections. Microphone Location of microphone 3TW57557-3 ERHQ011BV3 COOLING ERHQ014BV3 COOLING ERHQ016BV3 COOLING 7 Octave band center frequency (Hz) Octave band center frequency (Hz) Octave band center frequency (Hz) Notes: 1 Data is valid at free field condition (measured in a semi-anachoic room) 2 dba = A-weighted sound power level (A-scale according to IEC) 3 Reference acoustic pressure 0dB = 20µPa 4 If sound is measured under actual installation conditions, the measured value will be higher due to environmental noise and sound reflections. Measuring location (discharge side) 3TW57767-1B 148 Heating Daikin Altherma

7 Sound data 7-1 Sound pressure spectrum ERHQ006BV3 HEATING ERHQ007BV3 HEATING ERHQ008BV3 HEATING Octave band center frequency (Hz) Octave band center frequency (Hz) Octave band center frequency (Hz) Notes: 1 Data is valid at free field condition (measured in a semi-anachoic room) 2 dba = A-weighted sound power level (A-scale according to IEC) 3 Reference acoustic pressure 0dB = 20µPa 4 If sound is measured under actual installation conditions, the measured value will be higher due to environmental noise and sound reflections. Microphone Location of microphone 3TW57557-4 ERHQ011BV3 HEATING ERHQ014BV3 HEATING ERHQ016BV3 HEATING 7 Octave band center frequency (Hz) Octave band center frequency (Hz) Octave band center frequency (Hz) Notes: 1 Data is valid at free field condition (measured in a semi-anachoic room) 2 dba = A-weighted sound power level (A-scale according to IEC) 3 Reference acoustic pressure 0dB = 20µPa 4 If sound is measured under actual installation conditions, the measured value will be higher due to environmental noise and sound reflections. Measuring location (discharge side) 3TW57767-2B Heating Daikin Altherma 14

7 Sound data 7-2 Sound pressure spectrum quiet mode ERHQ011BV3 COOLING ERHQ014BV3 COOLING ERHQ016BV3 COOLING Octave band center frequency (Hz) Octave band center frequency (Hz) Octave band center frequency (Hz) Notes: 1 Data is valid at free field condition (measured in a semi-anachoic room) 2 dba = A-weighted sound power level (A-scale according to IEC) 3 Reference acoustic pressure 0dB = 20µPa 4 If sound is measured under actual installation conditions, the measured value will be higher due to environmental noise and sound reflections. Measuring location (discharge side) 3TW57767-3A 7 150 Heating Daikin Altherma

7 Sound data 7-2 Sound pressure spectrum quiet mode ERHQ011BV3 HEATING ERHQ014BV3 HEATING ERHQ016BV3 HEATING Octave band center frequency (Hz) Octave band center frequency (Hz) Octave band center frequency (Hz) Notes: 1 Data is valid at free field condition (measured in a semi-anachoic room) 2 dba = A-weighted sound power level (A-scale according to IEC) 3 Reference acoustic pressure 0dB = 20µPa 4 If sound is measured under actual installation conditions, the measured value will be higher due to environmental noise and sound reflections. Measuring location (discharge side) 3TW57767-4A 7 Heating Daikin Altherma 151

8 Installation 8-1 Installation method ERHQ-BV3 Outdoor unit Installation guidelines / precautions Daikin Altherma Installation location (General) n The equipment is not intended for use in a potentially explosive atmosphere. n The equipment is not intended for use in a potentially explosive atmosphere. n Choose a place solid enough to bear the weight and vibration of the unit, where the operation noise will not be amplified. n Choose a location where the hot/cold air discharger from the unit or the operation noise will not cause a nuisance to the neighbours of the user. n Avoid places near a bedroom and the like, so that the operation noise will cause no trouble. n There must be sufficient space for carrying the unit into and out of the site. n There must be sufficient space for air passage and no obstructions around the air inlet and the air outlet. n The site must be free from the possibility of flammable gas leakage in a nearby place. n Locate the unit so that the noise and the discharged hot/cold air will not annoy the neighbours. n Install units, power cords and inter-unit cables at least 3 m away from television and radio sets. This is to prevent interference to images and sounds. n Depending on radio wave conditions, electromagnetic interference may still occur even if installed more than 3 m away. n In coastal areas or other places with salty atmosphere of sulfate gas, corrosion may shorten the life of the outdoor unit. n Since drain flows out of the outdoor unit, do not place anything under the unit wicht must be kept away from moisture. Installation location (in cold climates) n To precent exposure to wind, install the outdoor unit with its suction side facing the wall. n Never install the outdoor unit at a site where the suction side may be exposed directly to wind. n To prevent exposure to wind, install a baffle plate on the air discharge side of the outdoor unit. n Unit shoud be installed in a way that a minimum of 10 cm free space is assured below the unit s bottom plate at all conditions, e.g.: heavy snowfall (if necessary construct a pedestal). n In heavy snowfall areas it is very important to select an installation site where the snow ill not affect the unit. If lateral snowfall is possible, make sure that the heat exchanger coil is not affected by the snow (if necessary construct a lateral canopy). (See figure) 8 Figure 1: construction of canopy and pedestal 4TW571-7 152 Heating Daikin Altherma

8 Installation 8-1 Installation method ERHQ011-016BV3 A. Non stacked installation Legend unit (mm) Suction side obstacle Discharge side obstacle Left side obstacle Right side obstacle Top side obstacle Obstacle is present This situation is not allowed. 1 In these cases, close the bottom of the installation frame to prevent discharged air from being bypassed. B. Stacked installation 1. Obstacles exist in front of the outlet side 2. Obstacles exist in front of the air inlet 2 In these cases, only 2 units can be installed. C. Multiple-row installation Do not stack more than one unit. About 100mm is required as the dimension for laying the upper outdoor unit s drain pipe. Get the portion A sealed so that air from the outlet does not bypass. 1. Installation of one unit per row 2. Installing multiple units (2 units or more) in lateral connection per row 8 Relation of dimensions of H, A, and L are shown in the table below. L H H < L L A 0 < L 1/2 H 250 1/2 H < L 300 Installation not allowed 3TW2673-4 Heating Daikin Altherma 153

Operation range Outdoor temp. ( CDB) Pull down area Cooling mode Leaving evaporator Water temperature ( C) Outdoor temp. ( CDB) Units with optional back up heater Heating mode leaving condensor Outdoor temp. ( CDB) Water temperature ( C) Booster heater operation only Sanitary mode Units with optional back up heater or booster heater operation only Water temperature sanitary tank (C ) 4TW57783-1 154 Heating Daikin Altherma

Operation range ERHQ011-016BV3 Outdoor temp. ( CDB) Cooling mode Leaving evaporator Water temperature ( C) Outdoor temp. ( CDB) No heat pump operation, back up heater only Heating mode *RLQ units include special equipment (insulation heater sheet,...) to ensure good operation in areas where low ambient temperature can occur together with high humidity conditions. In such conditions the *RHQ models may experience problems with severe ice build up on the aircooled coil. In case such conditions are expected, the *RLQ must be installed instead. These models contain countermeasures (insulation, heater sheet,...) to prevent freeze up. leaving condensor Water temperature ( C) Outdoor temp. ( CDB) Domestic hot water mode Booster heater operation only Domestic hot water tank temperature (C ) 4TW57753-1C Heating Daikin Altherma 155