Cooktop Chimney Ventilation Hoods

Similar documents
Downdraft Ventilation

INSTALLATION GUIDE Fryer Module

INSTALLATION GUIDE Steamer Module

INSTALLATION GUIDE Induction Cooktops

CAUTION signals a situation where minor injury or product damage may occur if you do not follow instructions.

Multi-Function Cooktop

I NDUCTION C OOKTOP INSTALLATION INSTRUCTIONS

INSTALLATION GUIDE Dual Fuel Ranges

INSTALLATION INSTRUCTIONS

Warming Drawer Installation Guide

Pro Ventilation Hood Liners

INSTALLATION GUIDE Warming Drawers

NEW CEILING-MOUNTED HOOD DESIGN GUIDE

Undercounter Refrigeration

NEW UNDER-CABINET HOOD INSERT DESIGN GUIDE

Installation Instructions

L Series Built-In Ovens

Integrated Ventilation System

DISHWASHER INSTALLATION GUIDE SPECIFICATIONS, INSTALLATION, AND MORE

READ AND SAVE THESE INSTRUCTIONS

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

D UAL F UEL R ANGES INSTALLATION INSTRUCTIONS

Installation Instructions

Cooktop Low-Profile Ventilation Hoods

Installation Instructions. Millennia Island (Ceiling Mount) Range Hoods. Models: DHI361, DHI421, DHI482 and DHI542

PRO VENTILATION HOOD USE AND CARE GUIDE CLEANING, MAINTENANCE, AND MORE

INSTALLATION INSTRUCTIONS

Installation Instructions

Features and specifications are subject to change at any time without notice. Visit wolfappliance.com/specs for the most up-to-date information.

Installation Instructions Preference Wall Mount Range Hood

C OOKTOP V ENTILATION H OODS USE &CARE INFORMATION

Installation Instructions

Installation Instructions Remote Blowers

High Power Range Hood

INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD

GAS COOKTOPS INSTALLATION INSTRUCTIONS. Model numbers ICBCG15 ICBCG304 ICBCG365

Downdraft Raised Vent

e Bath Fan with Light User s Guide

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN

e Bath Fan with Light User s Guide

IMPORTANT INSTRUCTIONS - OPERATING MANUAL

Installation Instructions

Installation Instructions

INSTALLATION INSTRUCTIONS

For use with models: PGM304-1, versions M-B PGM365-1, versions M-E, M-F & M-G

e Bath Fan with Light User s Guide

Easy installation. EZ80N EZ Fit Ventilation Fan INSTALLATION GUIDE READ AND SAVE THESE INSTRUCTIONS. Table of Contents

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE Euro-style Range Hood ESH5200

e Heater/Exhaust Fan/Light User s Guide

RV30, RV36, RV46. 30, 36, 46 Wide, Raised Vent. Adjustable anchor legs. Front View

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

GAS COOKTOP INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

Easy installation in both new construction and retrofit. READ AND SAVE THESE INSTRUCTIONS Installer: leave this guide with homeowner.

GE Monogram. Installation. Instructions. Component Cooktop System. Models ZEW145V ZGW124EN3 ZGW125EN3 ZEW155N ZEW166Y ZEW176Y

ERV3015, ERV3615. Renaissance 30, 36 Wide, High Extension Slim Raised Vents. Top cap with vent down

SEALED BURNER RANGETOPS

Installation Instructions

Model 8140 & 8141 Fresh Air Ventilator Installation and Operations Manual

Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer

INSTALLATION INSTRUCTIONS

GE Monogram. Installation. Instructions. Professional Gas Cooktops 48" Natural Gas Models ZGU48N4GWSS ZGU48N6RWSS ZGU48N6DWSS

Installation Instructions Use and Care Guide Instructions d installation Mode d emploi et d entretien

Over-the-Range Microwave Oven Installation Instructions MVH130* MVH230* MVH330*

Microwave Oven. IMPORTANT SAFETY INSTRUCTION Never operate the oven when it is empty or without the glass turntable.

READ AND SAVE THESE INSTRUCTIONS

Over the Range Convection Microwave Oven. Installation Instructions. Model: OTR111SU TINSEB399WRRZ

Installation Instructions Dual Fuel Ranges

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer

Self-Cleaning Range Hoods

Installation Instructions

Questions? Call 800.GE.CARES ( ) or visit our Web site at: GEAppliances.com In Canada, call or visit

Use, Care, and Installation Guide

Viking Installation Guide

Installation Instructions

Installation. Professional Built-in Hoods

INSTALLATION INSTRUCTIONS

Easy installation in both new construction and retrofit RN80L RN110L READ AND SAVE THESE INSTRUCTIONS INSTALLATION GUIDE

If you want to offer a more professional look to your

COPPER INSERT INSTALLATION INSTRUCTIONS, USE AND CARE GUIDE

Questions? Call 800.GE.CARES ( ) or visit our Web site at: GEAppliances.com In Canada, call or visit

Self-Cleaning Range Hoods

Ventilating Fan FV-05VFL2 FV-08VFL2 FV-11VFL

Questions on Installation? Call: GECARES (US) or Visit our Web site at: (US) 4" DUCT CLAMPS (2) OR 4" SPRING CLAMPS (2)

Installation Electric Dryers Instructions 01

UseandCare & Installation Guide

READ AND SAVE THESE INSTRUCTIONS

CATTURA TM DOWNDRAFT MODELS D49M30SB, D49M36SB, D49M48SB

Installation Instructions Wall Ovens

HUMIDITY SENSING BATH FAN

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE Air-O Ultra Series Range Hoods

Combination. IMPORTANT: Read and save. these instructions. Par-t No W / Rev. A

RWC Issue: F. Description: ARISTON WALL CANOPY Model Numbers: ARCH90BIX. Model may vary slightly from images pictured. All measurements are in mm.

New features make cooking a greater pleasure than

Microwave Oven Hood Combination

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

READ AND SAVE THESE INSTRUCTIONS Page 1

VENTILATION FAN WITH LED LIGHT AND HEATER MODEL RAD110LED

Transcription:

INSTALLATION GUIDE Cooktop Chimney Ventilation Hoods

Contents Wolf Cooktop Chimney Ventilation Hoods.......... 3 Cooktop Chimney Hood Specifications............ 4 Cooktop Chimney Hood Installation............. 10 Service Information........................... 18 Features and specifications are subject to change at any time without notice. Visit wolfappliance.com/specs for the most up-to-date information. IMPORTANT NOTE: Throughout this guide, dimensions in parentheses are millimeters unless otherwise specified. Important Note To ensure the safe and efficient use of Wolf equipment, please take note of the following types of highlighted information throughout this guide: IMPORTANT NOTE highlights information that is especially important. CAUTION signals a situation where minor injury or product damage may occur if instructions are not followed. WARNING states a hazard that may cause serious injury or death if precautions are not followed.

Wolf Cooktop Chimney Ventilation Hoods 3 wolfappliance.com/specs Cooktop Chimney Hood Installation IMPORTANT NOTE: This installation must be completed by a qualified installer or Wolf factory certified service. Read this entire installation guide prior to installation and save for the local inspector s reference. The homeowner should keep this installation guide for future reference. This appliance must be installed in accordance with National Electrical Codes, as well as all state, municipal and local codes. The correct voltage, frequency and amperage must be supplied to the appliance from a dedicated, grounded circuit which is protected by a properly sized circuit breaker or time delay fuse. The proper voltage, frequency and amperage ratings are listed on the product rating plate. IMPORTANT NOTE: Wolf cooktop chimney hoods are recommended for use with Wolf induction, electric and gas cooktops and integrated modules. For ranges and rangetops, a Wolf pro ventilation hood is recommended. Wolf Cooktop Chimney Hood Model Number Serial Number Record the model and serial numbers before installing the ventilation hood. Both numbers are listed on the product rating plate, located inside the left wall of the hood shell, above the filter. The filter must be removed to access the rating plate. Refer to the illustration below. RATING PLATE Location of rating plate. (inside hood).

Cooktop Chimney Hood Specifications 4 Overall Dimensions 30" (762) WALL HOOD 18" (457) 12" (305) 4 1 /2" (114) min 30 1 /2" (775) TO 48 1 /2" (1232) 19 1 /8" (486) 6" (152) 6 7 /8" (175) 30" (762) 21" (533) 1 9 /16" (40) 36" (914) WALL HOOD 18" (457) 12" (305) 4 5 /16" (110) min 32 11 /16" (830) TO 50 7 /8" (1292) 19 1 /8" (486) 8 11 /16" (221) 9 1 /4" (235) 35 7 /16" (900) 21" (533) 1 9 /16" (40) 42" (1067) ISLAND HOOD 18" (457) 12" (305) 5" (127) min 33 9 /16" (853) TO 47 1 /16" (1195) 19 5 /16" (491) 12" (305) 9 1 /4" (235) 42" (1067) 27" (686) 1 9 /16" (40)

Cooktop Chimney Hood Specifications 5 wolfappliance.com/specs Hood Placement Wolf cooktop chimney wall and island hoods come with a telescopic chimney flue that allows you to reach a ceiling height of 8' (2.4 m) to 9' (2.7 m) with a finished look. A flue extension to accommodate 10' (3 m) ceilings is available through your authorized Wolf dealer. For local dealer information, visit the find a showroom section of our website, wolfappliance.com. Installation of the cooktop chimney hood should be 24" (610) to 30" (762) from the bottom of the hood to the countertop. To determine placement of the hood, you must calculate the height of the telescopic chimney flue. The minimum and maximum flue extension for each cooktop chimney hood is listed in the chart. Cooktop Chimney Hoods FLUE EXTENSION MINIMUM MAXIMUM CTWH30 30 1 /2" (775) 48 1 /2" (1232) CTWH36 32 5 /8" (829) 50 7 /8" (1292) IH4227 33 1 /2" (851) 47" (1194) D MINIMUM FLUE EXTENSION Both sections of the telescopic chimney flue must be installed in order for the chimney to be lifted for service. IMPORTANT NOTE: 8' (2.4 m) ceilings may not permit installation of the wall or island hood at 30" (762) above the countertop. A C CALCULATE CHIMNEY FLUE HEIGHT A) Height from finished floor to finished ceiling. 8' (2.4 m) or 9' (2.7 m) ceilings are typical. B B) Height from finished floor to countertop. A 36" (914) countertop height is standard. Hood placement. C) Hood mounting height (bottom of hood to countertop). Dimension C must be between 24" (610) and 30" (762). 8' (2.4 m) ceilings may not allow the maximum 30" (762) hood mounting height. D) Calculate chimney flue height: D = A (B + C). Dimension D must be between the minimum and maximum flue extension listed in the chart. Refer to the illustration.

Cooktop Chimney Hood Specifications 6 Before You Start Proper installation is the responsibility of the installer. Product failure due to improper installation is not covered under the Wolf warranty. Refer to the cooktop chimney ventilation hoods use & care information for warranty details, or visit the contact & support section of our website, wolfappliance.com. Make sure you have the tools and materials necessary for proper installation. Any required service must be performed by a Wolf authorized service center. Wolf is not responsible for service required to correct a faulty installation. Wolf cooktop chimney hoods are shipped without the blower assembly. Internal, in-line and remote blowers are available through your authorized Wolf dealer. Installation Considerations Wolf cooktop chimney hoods are recommended for use with Wolf induction, electric and gas cooktops and integrated modules. Cooktop chimney wall and island hoods are shipped without the blower assembly. Internal, in-line and remote blowers are available through your authorized Wolf dealer. For local dealer information, visit the find a showroom section of our website, wolfappliance.com. The blower will vary in size and is dictated by the cooking unit, the volume of air that needs to be moved and the length of the duct run. Refer to ventilation recommendations in the Wolf design guide. These hoods have an 8" (203) round duct with vertical discharge. IMPORTANT NOTE: Use only a Wolf blower with the cooktop chimney hood. BACKSPLASH Optional stainless steel backsplashes are available in widths to match cooktop chimney wall hoods through your authorized Wolf dealer. For local dealer information, visit the find a showroom section of our website, wolfappliance.com.

Cooktop Chimney Hood Specifications 7 wolfappliance.com/specs Electrical Requirements Wolf cooktop chimney hoods require a separate, grounded 120 V AC, 60 Hz power supply. The service should have its own 15 amp circuit breaker. Locate the electrical supply within the shaded area shown in the installation illustration for your specific model on the following pages. For wall hoods, allow a minimum of 12" (305) Romex wire from the electrical supply location on the wall for wiring connections. For the island hood, allow a minimum of 6' (1.8) Romex wire from the electrical supply location on the ceiling for wiring connections. IMPORTANT NOTE: You must follow all National Electrical Code regulations. In addition, be aware of local codes and ordinances when installing your service.

Cooktop Chimney Hood Specifications 8 Installation CHIMNEY WALL HOODS 30 1 /2" (775) TO 48 1 /2" (1232) OR 32 11 /16" (830) TO 50 7 /8" (1292) HEIGHT OF HOOD LOCATION OF ELECTRICAL 4" (102) 6" (152) 9" (229) E 21" (533) DEPTH OF HOOD 30" (762) OR 35 7 /16" (900) WIDTH OF HOOD 24" (610) TO 30" (762) TO COUNTERTOP SIDE VIEW FRONT VIEW

Cooktop Chimney Hood Specifications 9 wolfappliance.com/specs Installation CHIMNEY ISLAND HOOD LOCATION OF ELECTRICAL THROUGH TOP OF HOOD 33 9 /16" (853) TO 47 1 /16" (1195) HEIGHT OF HOOD 27" (686) DEPTH OF HOOD 42" (1067) WIDTH OF HOOD 24" (610) TO 30" (762) TO COUNTERTOP SIDE VIEW FRONT VIEW

Cooktop Chimney Hood Installation 10 Install Ductwork To reduce the risk of fire, use only metal ductwork. IMPORTANT NOTE: Cooktop chimney ventilation hoods must exhaust to the outdoors. An 8" (203) round duct is recommended for cooktop chimney hoods. Use only rigid metal ductwork, do not use flex ducting. Local building codes may require the use of make-up air. Consult your local HVAC professional for specific requirements in your area. IMPORTANT NOTE: Consult a qualified HVAC engineer for specific ducting applications. To reduce the risk of fire and electric shock, install this ventilation hood only with a Wolf blower. Decide where the ductwork will run between the wall hood and the outside. A straight, short duct run will allow the hood to perform most efficiently. Limit the number of elbows and transitions. The duct run should be no longer than 50' (15 m). There is a possibility of noise issues, if a remote blower is used with a short duct run. Wolf recommends installing a backdraft damper in all installations. A backdraft damper is included with the hood. It is built into the transition from the hood to the duct run. In cold weather installations a backdraft damper is necessary to minimize the backflow of cold air into the room. Unless you are using a remote blower, a roof or wall cap must be installed. Connect ductwork to the cap and work back towards the hood. Use duct sealing tape to seal joints between ductwork sections. Refer to the illustrations on the following page.

Cooktop Chimney Hood Installation 11 wolfappliance.com/specs Install Ductwork CHIMNEY WALL HOODS CHIMNEY ISLAND HOOD DUCTWORK INSTALLATION THROUGH ROOF DUCTWORK INSTALLATION THROUGH ROOF 30 1 /2" (775) TO 48 1 /2" (1232) OR 32 5 /8" (829) TO 50 7 /8" (1292) TELESCOPING HOOD HEIGHT DUCTWORK INSTALLATION THROUGH WALL 12" (305) 33 1 /2" (851) TO 47" (1194) TELESCOPING HOOD HEIGHT 12" (305) DUCTWORK INSTALLATION THROUGH EAVE INTERNAL BLOWER 21" (535) HOOD DEPTH 27" (686) HOOD DEPTH 24" (610) TO 30" (762) BOTTOM OF HOOD TO COUNTERTOP 24" (610) TO 30" (762) BOTTOM OF HOOD TO COUNTERTOP

Cooktop Chimney Hood Installation 12 Wall Hood Installation Locate the electrical supply for the wall hood through the wall within the shaded area shown in the illustration on page 8. Install ductwork as specified on pages 10 11. IMPORTANT NOTE: If a backsplash is to be used, it should be installed prior to mounting the wall hood. Secure the hood mounting brackets to the wall studs prior to installing the backsplash. Refer to installation instructions provided with the backsplash. INSTALL MOUNTING BRACKETS INSTALL HOOD Hang the wall hood from the brackets through the rectangular cut-outs on the back of the hood. Refer to the illustration below. The cut-outs are larger than the brackets to allow for vertical and horizontal adjustment. Use height adjustment screws to adjust the hood vertically and the depth adjustment screws to adjust the hood horizontally. Secure the hood with additional mounting screws. IMPORTANT NOTE: Wolf recommends that the bottom of the ventilation hood be installed 24" (610) to 30" (762) above the countertop. Construct wall framing that is flush with the interior surface of the wall studs. Make sure that the framing is centered in the hood installation location, and that the height of the framing will allow the mounting brackets to be secured to the framing within the dimensions shown in the illustration below. MOUNTING BRACKET After the wall surface is finished, secure the mounting brackets to the framing using the dimensions shown. RECTANGULAR CUT-OUT Install hood. FRAMING (BEHIND DRYWALL) MOUNTING BRACKET 7 1 /2" (190) CTWH30 9 3 /8" (238) CTWH36 Install mounting brackets.

Cooktop Chimney Hood Installation 13 wolfappliance.com/specs Wall Hood Installation WIRING CONNECTIONS Electrical connection at the hood: 1) Remove the cover from the rear electrical box. Remove the electrical box knockout that faces the hood's discharge collar. 2) Insert 6" (152) Romex wire through the knockout opening. Secure the Romex wire to the electrical box with an appropriate connector. Use wire connectors or wire nuts approved by UL or C/UL. 3) Make electrical connections at the hood. Connect black to black, white to white and green/yellow to green or bare wire. ATTACH CHIMNEY FLUE Use the screws and wall anchors provided to secure the upper brackets for the chimney flue to the ceiling. Position the upper brackets based on the dimensions of the chimney flue. Refer to the illustration below. Use 8" (203) round metal duct to connect the duct collar on the hood to the ductwork above. Use duct sealing tape to make all joints secure and air tight. Fasten the upper section of the telescopic chimney flue to the brackets with the screws provided. Refer to the illustration below. Nest the bottom of the chimney flue into the relief in the hood shell. 4) Place all wiring connections inside the electrical box and reinstall the cover. Make sure all wires are secure and that no wires are pinched between the cover and electrical box. Refer to page 13 15 for internal blower installation and remote blower wiring. UPPER BRACKET SCREWS Upper brackets. Chimney flue.

Cooktop Chimney Hood Installation 14 Island Hood Installation Locate the electrical supply for the island hood through the ceiling within the dimensions of the chimney flue. Install ductwork as specified on pages 10 11. INSTALL SUPPORT SYSTEM IMPORTANT NOTE: Wolf recommends that the bottom of the ventilation hood be installed 24" (610) to 30" (762) above the countertop. At the island hood installation location, install 2" (51) x 4" (102) or 3 /4" (19) plywood cross framing between ceiling joists. Refer to the island hood mounting pattern dimensions below. Finish the ceiling surface. Be sure to mark the location of the ceiling joists and cross framing. Determine the desired orientation of the island hood. Note that the front designates the control side of the hood. Secure the upper half of the support frame to the joists and cross framing with four screws (provided). Make sure that the screws are driven into the center of the joists and framing for maximum strength. Ensure the correct orientation of the support frame. Refer to the illustration below. Adjust the overall height of the support frame. Loosen and retighten the screws in the height adjustment slots as necessary. IMPORTANT NOTE: The hood height is 11 1 /4" (286) from the support frame attachment point. CONNECT CHIMNEY FLUE Secure the upper chimney flue section to the upper support frame with the screws provided. Refer to the illustration below. Temporarily hold the lower chimney flue section over the upper flue section. MOUNT HOOD TO SUPPORT FRAME Mount the hood to the support frame by aligning the four weld screws on the hood to the four holes on the support frame. Use four nuts (provided) to secure the hood to the support frame. Refer to the illustration below. Nest the bottom of the telescopic chimney flue into the relief in the hood shell. Make electrical connections. UPPER FLUE SECTION SCREW SUPPORT FRAME WELD SCREW SCREW 6 1 /2" (165) 7 13 /16" (198) Upper flue section. Mount hood to support frame. 6 1 /2" (165) 10 7 /8" (276) HEIGHT ADJUSTMENT SLOTS SUPPORT FRAME (FRONT) FRONT OF HOOD (TOP VIEW) Mounting pattern. Support frame.

Cooktop Chimney Hood Installation 15 wolfappliance.com/specs Island Hood Installation WIRING CONNECTIONS Electrical connection at the hood: 1) Remove the cover from the rear electrical box. Remove the electrical box knockout that faces the hood's discharge collar. 2) Insert 6" (152) Romex wire through the knockout opening. Secure the Romex wire to the electrical box with an appropriate connector. Use wire connectors or wire nuts approved by UL or C/UL. 3) Make electrical connections at the hood. Connect black to black, white to white and green/yellow to green or bare wire. 4) Place all wiring connections inside the electrical box and reinstall the cover. Make sure all wires are secure and that no wires are pinched between the cover and electrical box. Refer to page 13 15 for internal blower installation and remote blower wiring. Internal Blower INTERNAL BLOWER INSTALLATION IMPORTANT NOTE: Refer to installation instructions provided with the internal blower assembly for additional mounting and wiring instructions. 1) Remove the hood filters. 2) Lift the blower into position inside the hood. 3) Use four hex nuts provided with the blower to fasten the unit to four threaded studs. 4) Plug the blowers single power cord (double for 900 CFM) into the receptacle(s) inside the hood. Use the clip on the hood to keep excess power cord away from moving parts. 5) Reinstall the hood filters. IMPORTANT NOTE: Before turning the power on to the ventilation hood, make sure the blower is off. CONNECT DUCTWORK Use 8" (203) round metal duct to connect the duct collar on the hood to the ductwork above. Use duct sealing tape to make all joints secure and air tight. Slide the lower telescopic chimney flue section downward until it fits properly around the hood shell.

Cooktop Chimney Hood Installation 16 In-Line and Remote Blowers BLOWER INSTALLATION IMPORTANT NOTE: Refer to specific installation instructions provided with each blower assembly for additional mounting and wiring instructions. Locate the blower so that the length of the duct run and number of elbows and transitions are kept to a minimum. The duct run should be no longer than 50' (15 m). Remote blowers should be located between wall studs or roof rafters. Avoid pipes, wires and other ductwork. Allow enough space for transitions needed between the blower and connecting ductwork. For best performance, locate transitions nearest the blower. Refer to the illustrations below for overall dimensions of Wolf in-line and remote blowers. Installation instructions shipped with each Wolf ventilation product provide detailed specifications. These instructions can also be found on our website, wolfappliance.com/specs. IN-LINE AND REMOTE BLOWER DIMENSIONS 24 3 /8" (619) 24 7 /8" (632) 11 3 /4" (298) 18 1 /2" (470) 18" (457) 12" (305) 4 1 /2" (114) 8" (203) 21 1 /2" (546) 12 1 /4" (311) 22" (559) 18" (457) 600 CFM in-line blower. 1100 CFM in-line blower. 18" (457) 21" (533) 28 1 /4" (718) 10" (254) DIAMETER 20 3 /4" (527) 29 1 /2" (749) 10" (254) DIAMETER 10" (254) 29 1 /2" (749) 10" (254) DIAMETER 10" (254) 15 1 /2" (394) 24 1 /2" (622) 14 3 /4" (375) 29 1 /2" (749) 14 3 /4" (375) 29 1 /2" (749) 14" (356) 24 3 /4" (629) 4 3 /4" (121) 10 1 /8" (257) 22" (559) 71 /4" (184) 10 3 /8" (264) 25" (635) 71 /4" (184) 600 CFM and 900 CFM remote blower. 1200 CFM remote blower. 1500 CFM remote blower.

Cooktop Chimney Hood Installation 17 wolfappliance.com/specs In-Line and Remote Blowers IN-LINE OR REMOTE BLOWER WIRING IMPORTANT NOTE: Refer to installation instructions provided with the in-line or remote blower assembly for additional mounting and wiring instructions. Blower connection at the hood: 1) Remove the cover from the front of the electrical box. Remove the electrical box knockout that faces the hood s discharge collar. 2) Disconnect the red and black or white wires using a flat-blade screwdriver. 3) Insert 6" (152) Romex wire through the knockout opening. Secure the Romex wire to the electrical box with an appropriate connector. Use wire connectors or wire nuts approved by UL or C/UL. 4) Attach the remote blower wiring where wires were removed in step 2. Attach white to white, black to red, and ground to yellow. 5) Place all wiring connections inside the electrical box and reinstall the cover. Make sure all wires are secure and that no wires are pinched between the cover and electrical box. IMPORTANT NOTE: Before turning the power on to the ventilation hood, make sure the blower is off.

Service Information 18 Troubleshooting IMPORTANT NOTE: If the ventilation hood does not operate properly, follow these troubleshooting steps: Verify that electrical power is being supplied to the ventilation hood. Check electrical connections to ensure that the installation has been completed correctly. Refer to the troubleshooting guide in the Wolf cooktop chimney ventilation hoods use & care guide. If the ventilation hood still does not operate properly, contact Wolf factory certified service. Do not attempt to repair the hood yourself. Wolf is not responsible for service required to correct a faulty installation. Service Information If service is necessary, maintain the quality built into your ventilation hood by contacting Wolf factory certified service. For the name and number of Wolf factory certified service nearest you, check the contact & support section of our website, wolfappliance.com or call Wolf customer care at 800-222-7820. When calling for service, you will need the model and serial numbers of the ventilation hood. Both numbers are listed on the product rating plate, located inside the left wall of the hood shell, above the filter. The filter must be removed to access the rating plate. Refer to the illustration below. RATING PLATE Location of rating plate. (inside hood).

The information and images in this guide are the copyright property of Wolf Appliance, Inc. Neither this guide nor any information or images contained herein may be copied or used in whole or in part without the express written permission of Wolf Appliance, Inc. Wolf Appliance, Inc. all rights reserved. Wolf, Wolf & Design, Wolf Gourmet, W & Design and the color red as applied to knobs are registered trademarks and service marks of Wolf Appliance, Inc. Sub-Zero, Sub-Zero & Design, Dual Refrigeration, Constant Care and The Living Kitchen are registered trademarks and service marks of Sub-Zero, Inc. (collectively, the Company Marks. ) All other trademarks or registered trademarks are property of their respective owners in the United States and other countries.

WOLF APPLIANCE, INC. P. O. BOX 44848 MADISON, WI 53744 WOLFAPPLIANCE.COM 800.222.7820 820619 REV-A 11/2011