FDC/ -B. Product information SYSTEM TECHNOLOGY FOR THE DOOR ECO

Similar documents
ECO ETS Electromotive drive

Universal operator - easy to install, reliable in operation

Product and Applications Description

csw-200 intro d u c t i o n

DFA 127. record DFA 127 automatic drive system for swing doors. record your global partner for entrance solutions

Movement-based energy control

BL 53 Security Barrier ENGINEERING SPECIFICATIONS

ABLOY DOOR AUTOMATICS Easy access for all types of swing doors

ABLOY DOOR AUTOMATICS Easy access for all types of swing doors

Security Door Closer Safe and secure by design. ASSA ABLOY Door Controls

ED 100 ED 250. Swing door drives

ABLOY DA460 SWING DOOR OPERATOR. Installation and commissioning manual

record DFA 127 The silent, energy-saving automatic swing door operator

Orthos PIL-M02 SENSOR CONTROLLED ONE-WAY CORRIDORS

ED 100 ED 250. Swing door drives

Automatic Sliding Door Systems

DC200 Rack and pinion door closer with link arm

Automated Entrance Accessories. ADA compliant door control without compromise

LZR -H110. LASER SCANNER FOR BARRIERS & GATES with max. detection range of 5.0 m x 6.5 m (16.5 ft x21 ft) User s Guide

BLG77 Rising Fenced Barrier

Automatic swing door solutions. We make access in life smart and secure.

AUTOMATIC DOOR RANGE COMFORT FOR CONNECTED PEOPLE

GEZE AUTOMATIC DOOR SYSTEMS GEZE ACTIVATION DEVICES AND SENSOR SYSTEMS PERFECTLY CONTROLLED AUTOMATIC DOOR DRIVES BEWEGUNG MIT SYSTEM

Carey Automatic Door, LLC 1 - PNEUMATIC OPERATOR FOR SINGLE SWINGING DOOR

PHA Panic Hardware for timber doors

DESIGN EASY ADJUSTMENT

LZR -FLATSCAN SW SAFETY SENSOR FOR FULL- AND LOW-ENERGY AUTOMATIC SWING DOORS. Visit website for available languages of this document.

Pedestrian Swing and sliding doors. Accessories

FLEXIBLE DOOR SOLUTIONS FOR VARIOUS BUILDING TYPES. KONE automatic sliding doors

Electrical Specifications

1 Door closers. Door closers Technical information. The global leader in door opening solutions.

Engineering Specifications

Universal Dimmer N 528D01, 2 x 300VA, AC 230 V 5WG DB01

FLEXIBLE DOOR SOLUTIONS FOR VARIOUS BUILDING TYPES. KONE automatic sliding doors

BL41 Extra-long Barrier

Datasheet - AZM 161SK-12/12RK-024

5900 SERIES Low Energy Power Operator

LZR -FLATSCAN SW SAFETY SENSOR FOR FULL- AND LOW-ENERGY AUTOMATIC SWING DOORS

SECTION AIR DUCT ACCESSORIES

Performance Specifications LSF LIFT-SMOKE-FREE

REMOTE CONTROL CAR ALARM SYSTEM

AUTOMATIC PEDESTRIAN ACCESS

DC300 Rack and pinion door closer with link arm

AUTOMATIC FIRE CURTAIN FIRE CURTAIN FM 1

Multifunctional Gate Box MGB. More than safety.

TPW-900ETS01. Product Manual. Intelligent Swing Gate Turnstile

DC340 Rack and pinion door closer with guide rail or link arm

Fire and Smoke Door Inspections Qualified Training 02/03/17

01_TT_TST_04_61_GB.qxd :30 Uhr Seite 4. Door Closers and Door Control Systems

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation

Viewguard Motion detctors PIR and DUAL detectors

Intelligent Swing Gate Turnstile Operating Manual CPW-322CS

HX-80NRAM. High Mount Outdoor Detector

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

All by design. ASSA ABLOY Door Controls

GEZE AUTOMATIC DOOR SYSTEMS GEZE ACTUATION DEVICES AND SENSOR SYSTEMS PERFECTLY CONTROLLED AUTOMATIC DOOR DRIVES BEWEGUNG MIT SYSTEM

Power Transfer Devices. Access Control Accessories. How To Order. How to Order

ABLOY FIRE DOOR CLOSING SYSTEMS

DC300 Rack and pinion door closer with link arm

DICTATOR Hold-Open Systems for Hazardous Areas

Datasheet - AZM 161SK-12/12RK-024

Engineering Guideline. pac-carriers Type for TRICON system TRICONEX TMR PLC

Infrared Wall Mount Occupancy Sensor

RA 701 B Batterie assembling. As at: 01/15/10 Time:21:19

SECTION XPRESS II INCLINED WHEELCHAIR PLATFORM LIFT. Display hidden notes to specifier by using Tools / Options / View / Hidden Text.

A. AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA) 101: Appendix Dissimilar Materials.

ARCHITECTURAL SPECIFICATIONS

CommStat 4. Controller for Redundant Telecom HVAC Systems PRODUCT DATA SHEET. Features and Benefits

STANDARDS UPDATE NOTICE (SUN) ISSUED: March 19, 2018


RITTNER FRENCH ASSOCIATES Rittner French Associates / Rittner Products, Inc.

Power Locking Installation Manual

Eclipse MC240. Double & Single Gate Controller with Eclipse Operating System (EOS) 3rd Edition. MC240 for Double and Single Gates.

SAFETY STANDARDS & SOLUTIONS MATERIAL HANDLING & INTRALOGISTICS

CONTENTS 1. SPECIFICATIONS SET-UP FOR THE OPERATOR MAINTENANCE... 34

ASSA ABLOY Door Closers. Rack & Pinion Closer DC120 HOLD OPEN DC120 NON HOLD OPEN EN 2/3/4

A. Section Masonry Assemblies: Anchor placement in masonry.

Instruction manual. Digital Radar Motion Detector with Infrared Remote Control MWD BF. FEIG ELECTRONIC GmbH Lange Straße Weilburg/Lahn

MBCE-110/230UV Flame Sensor Module

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

ELECTROPROJECT GTV-A POWER SUPPLY FOR DOOR MAGNETS

Besam SW200i-Fold Folding Door Series. Owner s Manual

DS160/161 Request To Exit PIR sensors Installation Instructions

Layout S. 6 DORMA CI-2012 Englisch Stand

Updated to. include Declaration of Performance Certificates WHICH DOOR CONTROL? Meeting the requirements of the Equality Act & Fire regulations

Instructions for Use

INFRARED MODULATED BARRIERS

operating device LOD , 144x72mm designed for retrofit

Replacement of pneumatic actuators on Ruskin negator spring dampers with Belimo FSxx Series

ELECTRIC LOCKS. Europrofile range

SIMPLY THE WIDEST FOLDING DOOR. FFT FLEX Green. Maximum clear opening widths and best thermal separation.

Catalogue: TEH_02G. Hardware for Sliding Doors (Glass)

Installation Instructions Azatrax Dual Infrared Model Train Detector MRD2 'Turnout' Edition

Products documentation (REVISION DATE: 03/10/2011) OMFP6010 (60cm PIROLITIC OVEN)

Dec Wirsbo CoSy Radio. Installation and Operating Instructions

BERNSTEIN Safety Rope Pull Switches SR and SRM

can be implemented, e. g. as counter closures and are the only fire protection roller doors authorized for higher position of installation.

Catalogue: TEH_02G. Hardware for Sliding Doors (Glass)

Meeting the requirements of the Equality Act & Fire regulations. Which Door Control?

User manual and installation instruction Control for Fire Ventilation RV / RV 24-32

Transcription:

ECO FDC/ -B Product information SYSTEM TECHNOLOGY FOR THE DOOR

FDC / -B Product characteristics FDC FDC- B Closing force Size acc. to EN (continuously adjustable) 3 6 4 6 Door width acc. to EN Dimensions (incl. mounting plate) < 1.400 mm Fire protection doors < 1.400 mm Length in mm Depth in mm Height in mm - - 530 104 530 104 104 530 Hinge side with slide rail - Hinge-opposite side with standard arm Dimensions: FDC / -B DIN left / right Opening speed adjustable Closing speed adjustable when mains operated, fixed when power failure Hold-open time adjustable 1 30s Driving power adjustable Door opening angle 70-105 Yes - No Option TÜV-certified Suitable for fire- and smoke control doors - Certified according to EU-Directive ECO FDC / -B Opened by an electric motor - Controlled closure Opened by an electric motor - controlled closure via a spring mechanism. The integrated damper unit stops the door from slamming shut. Automated door closure helps keep out airborne dust, wind gusts, odours and noise. If there is a power cut, the door can be closed by means of its spring mechanism from any position. The use of top quality components guarantees optimum performance and extended product life with minimal maintenance. ECO FDC / -B Swing-door drive units are ideal both for new installations and building upgrades. The wide range of functions creates user-friendly access, while providing individual configuration of operating functions. Lightweight doors, heavy gates and even fire-rated doors can be automated without difficulty. Power is intelligently harnessed in order to monitor the system and provide smooth operation with maximum reliability and security. Safety and security elements can include, depending on the building design, light barriers (photoelectric cells) or light scanners. Our drive mechanism is designed for the convenient, automatic operation of standard doors, and can be supplied with reliable fire-protection options when used to operate fire-rated doors. Safety sensors with configurable functions Reverse and Stop functions offer additional protection at the pinch points and in the event of oncoming traffic. Risk elimination through planning Together with the customer, ECO Schulte conducts a joint risk assessment (under consideration of the door user group and specific construction situation) in accordance with the standard DIN 18650 which describes the technical safety requirements for automatic door systems. This then forms the basis for the selection of various safety and security measures. Risk assessment is carried out during the planning phase so that the automatic door system can be installed and operated safely and reliably.

FDC / -B Order information ECO FDC / -B Product description Safe and reliable opening and closing Technical specifications: FDC Main supply 230 V, 50 Hz, 13 A Motor power consumption < W Ambient temperature 15 to +70 C Use in dry rooms max. relative air humidity 65% Door opening angle 70 105 Opening speed adjustable Closing speed adjustable with mains operation, fixed if there is a power failure Hold-open time 1 30 sec (adjustable) Driving power adjustable TÜV-certified acc. to DIN 18650 Dimensions 530 x x 104 mm Weight incl. standard arm 11,3 kg Basic planning data FDC FDC-B for fire-rated doors Door panel width max. 700-1400 mm max. 900-1400 mm Activ range Doors EN 3-6 Doors EN 4-6 Opening and closing Motor-actuated opening, closure by spring force. The spring provides improved closing power to reinforce the shutting action. Function «Closing» The door closes under full If a fire alarm or power cut is control by spring action from activated, the any position (self closure if door closes under full control power fails). from any position by means of spring action. A range of individual extra functions is also available: Reinforced closure Push and go function Adjustable opening width Safety monitoring with automatic stop/reverse mechanism Progressive regulation of opening and closing speed, hold-open time and motor power Optical/acoustic signal during movement of door mechanism Automatic closing sequence control for two-winged (bi-parting) systems Dry contact for further processing of information at a central building control point, or the connection of an electric lock, door open/shut signal, error display Article numbers Swing-door drive unit without arm Colour Article number FDC (3-6) Stainless steel 358500547000 FDC-B (4-6) Stainless steel 358500547100 Slide rail for FDC (up to 160 Colour Article number mm under-lintel depth) FDC Stainless steel 358500547120000 Standard arm for FDC and FDC-B Colour Article number (up to 250 mm under-lintel depth) FDC / FDC-B Stainless steel 358500547120 Please order safety elements which offer additional protection at squeezing points and for opposing traffic separately. Infrared sensor strips acc. to DIN 18650! Please refer to page 181 for more information.

A joint casing for both drive units is available as an optional extra. ECO FDC / -B The convenient, high-performance solution. Automation considerably enhances the user comfort of a traditional, manually-operated door. The flow of pedestrian traffic is increased. Cumbersome, difficult-to-open doors become much easier to use. A motion detector can be used to provide contact-free access. Reliable door closure prevents a loss of valuable heated or cooled air in the building, resulting in large energy savings. The swing-door drive unit supports management functions such as controlled access and fire safety. Movement is monitored by a series of standard and norm compliant safety elements. Wherever people work, travel, live, are cared for or congregate, there is a need for doors to facilitate their comings and goings. The automation of doors offers smooth access with unobstructed entry and exit. These drive mechanisms are ideal for use in public buildings, hospitals, hotels, airports, and industrial and commercial premises.

FDC / -B Cable plan FDC-B 11 1 10 2 3 8 4 5 6 7 9 Pos. Product, safety and handling elements Description cable information 1 ECO FDC-B hinge-opposite side incl. mounting plate, mounting acc. to EN 3 x 1,5 mm² to Pos.12 2 Standard arm, hinge-opposite side 3 Sensor strip, hinge-opposite side, revers Cable by ECO, cable channel by building contractor 3.1 Sensor strip, BS, Stop Cable by ECO, cable channel by building contractor 4 Flip switch inside, with surface-mounted socket 4 x 0,8 mm² 4.1. Flip switch outside, with surface-mounted socket 4 x 0,8 mm² 5 Key sense switch 4 x 0,8 mm² 6 Push button "Door close" 4 x 0,8 mm² 7 Bedis - sense switch with LED display 4 x 0,6 mm² 8 Electric opener 4 x 0,8 mm² 9 Dead bolt switch contact 4 x 0,8 mm² 10 Switch ORS 142 W 4 x 0,8 mm² 11 Celling switch ORS 142, inside 4 x 0,8 mm² 11.1 Celling switch ORS 142, outside 4 x 0,8 mm² 12 Home office socket 3 x 1,5 mm² 230 V, 50 Hz, 13A 13 Radar OKI (inside) 13.1 Radar OKA (outside)

FDC / -B Assembly FDC Assembly of ECO FDC 2 3 12 6 17 13 7 2 19 Connector block 20 21 18 1 22 5 11 10 Drive unit 4 16 15 16 14 9 23 8 1 Chassis 2 Side cover 3 Sense switch 1-0-2 4 Power cable 5 Logic cable 6 Drive unit 7 DC motor with interference electronic 8 Poly-V-belt transmission 9 Synchronous belt transmission 10 Linkage transmission 11 Driven shaft 12 Door surveillance switch 13 Controller (with Logic-Servo-Unit LOSE) 14 DIL switch 15 Potentiometer 16 Light-emitting diode (status indicator) 17 Signal buzzer 18 Connector block 19 Clamp 20 Clamps for operation and safety elements 21 Fine-wire fuse 1 AT, 5 x 20 mm 22 Reset button 23 Plug (mechanical closing)

FDC Mounting drawing FDC single-leaf door, illustration DIN right -door, DIN left laterally reversed max. 250 ~385 128 172 292 Installation on door frame with standard arm on hinge-opposite side for single-leaf doors (FDC, pushing) 45 408 72 58 14 28 72 408 45 14 28 58 292 172 128 Installation on door leaf with standard arm on hinge-side for single-leaf doors (FDC, pushing) 104 68 292 172 10-35 89 72 210 600 Installation on door frame with slide rail on hinge-side for single-leaf doors (FDC, pulling)

FDC / -B Mounting drawing FDC-B single-leaf door, illustration DIN right, DIN left laterally reversed max. 250 ~385 C 500 44 Installation on door frame with standard arm on hinge-opposite side for single-leaf doors (FDC, pushing) F Range of application FDC 400 350 300 250 200 150 50 0 Weight incl. standard arm (fire-protection version) Weight with parallel and sliding arms for interior doors too narrow for wheelchair users 0,70 0,75 0,80 0,85 0,90 0,95 1,00 1,05 1,10 1,15 1,20 1,25 1,30 1,35 1,40 max. 14 A B D Please refer to following table in order to check for the corresponding closing force: EN Door width A B C D EN 4 950 1. mm 265 378 15 135 EN 5 1.101 1.250 mm 285 348 35 85 EN 6 1.251 1.400 mm 374 413 124 61 Recommended weight of door leaf (kg) Clearance width (m)

FDC Mounting drawing FDC Double-wing door, illustration DIN right, DIN left laterally reversed 128 172 292 Y X 292 172 128 14-28 max. 250 385 58 72 408 45 45 408 360 70 70 360 56 56 Y = Hinge gap in mm; X = Y-1184 Double-wing execution with master and slave control, mounting with standard arm (hinge-opposite side) 68 292 172 Y X 172 292 68 104 89 72 210 600 600 210 10-35 56 56 300 300 Y = Hinge gap in mm; X = Y-1064 Double-wing execution with master and slave control, mounting with slide rail (hinge side)

FDC-B Mounting drawing FDC-B Double-wing door, illustration DIN right, DIN left laterally reversed C 500 Y X 500 C max. 250 max. 14 ~385 A A 44 B D D B A D D A 66 114 114 66 Y = Hinge gap in mm; X = Y-(+2xC) Double-wing execution with master and slave control or with mechanical closing sequence SR (for the use on smoke - and fire-protection doors) F Please refer to following table in order to check for the corresponding closing force: EN Door width A B C D EN 4 950 1. mm 265 378 15 135 EN 5 1.101 1.250 mm 285 348 35 85 EN 6 1.251 1.400 mm 374 413 124 61 Mechanical closing sequence system for FDC / -B The closing sequence selector ensures that in case of fire or power failure the door leafs are closing in the correct order. That means: passive leaf (1) first, active leaf (2) last. 2 1 Closing sequence selector Closing sequence selector SR Closing sequence selector SR-TS Closing sequence selector SR-EF-1S Dual locking device 1 / 2 MK Basis-1 incl. two pivot hinges, automisation of active and passive leaf incl. pivot hinge and TS-61, automisation of active leaf incl. pivot hinge and TS-61, automisation of active leaf, hold-open in passive leaf for automatic locking and unlocking of passive leaf Panic flap for full panic doors in fire protection

ECO Schulte GmbH & Co. KG Iserlohner Landstraße 89 D - 58706 Menden Telefon: +49 2373 / 9276-0 Fax: +49 2373 / 9276-40 info@eco-schulte.de www.eco-schulte.de ECO Schulte GmbH & Co. KG - Änderungen vorbehalten ECO Schulte GmbH & Co. KG - Subject to change