RECOMMENDATIONS FOR INSTALLATION

Similar documents
AQUACALK EQUIPMENT. Description of the problem:

J-PRO-24 Pump Chlorinator. Installation & Start-Up Guide

STORAGE WATER HEATERS

9.0 Systems For Domestic Water Installations

Ultraviolet Water Sterilizer Installation and Maintenance Manual

Chanson Water USA, INC. Installation Guide for SCF-3000/SCF-6000

/2010 US/CA

AQUABION Galvanic water treatment for limescale & corrosion Frequently Asked Questions (FAQ s) June 2018

OPERATING AND INSTALLATION MANUAL

ELECTRIC BOILERS FOR CENTRAL HEATING

AQUAS POOL PACKAGE INSTALLATION INSTRUCTIONS FOR MODELS: XPN AQUAS Pool Package

WHAT LURKS BELOW THE WATERS OF YOUR CENTRAL HEATING SYSTEM?

Form 2143 Date: 4/3/03 Repl: 2/1/99 BRYAN STEAM LLC. Installation and Operating Service Manual BOILER FEED SYSTEM

INSTALLATION & SERVICE MANUAL

J-PRO-24 Soda Ash Injection Installation & Start-Up Guide

Magnetic-Inductive Flow Velocity Sensor PIT. Installation and Operating Instructions

EN Variable Temperature Electric Kettle

Step-by-Step Guide To Clean Your Own Pool

Air and dirt in closed systems

ACO Marine Advanced wastewater solutions for the marine and offshore market

EYS SEPARATOR EYS 01 G. USER MANUAL for EYS SCREW-PRESS SEPARATOR MODEL EYS 01 G. User Manual for EYS 01G Screw-Press Separator

Descaler & Prevention

Owners Instruction Manual

smardy - pure water Reverse osmosis system YR100-A 75 GPD

AQUAS POOL PACKAGE INSTALLATION INSTRUCTIONS FOR MODELS: AP AQUAS Pool Package

COMMERCIAL ELECTRIC WATER HEATER OWNER S MANUAL OPERATION AND MAINTENANCE INSTRUCTIONS

JT-SB116JH-G-NA JT-SB116JH-W-NA

INSTALLATION INSTRUCTIONS OWNERS GUIDE & WARRANTY STATEMENT

Other Things I Should Know?

HYDRAULIC OIL COOLER Installation, Operation & Maintenance Guide

EKO-LIT RECYCLING UNITS:

Summary of Conversion Steps. 1. Obtain the abandonment/conversion permit from the Department of Health.

Scale Stopper Plus Installation & Start-Up Guide

Installation and Operating Service Manual

CEHA Fall Chloride Workshop. Chloride Treatment Options Presented by Paul Hurlbut Professional Water Systems, Inc.

Operation and Maintenance Haskris LX-Series, R-Series, WW-Series, OPC-Series

CENTRA-COIL QUALITY HOT WATER SERVICE

Heating for Soft Fruit

p Permanent magnet water cooled motors Additional manual

user manual Dishwasher ESL 46510

REG NO FM BS EN ISO HEADER TANK HEAT EXCHANGER. Installation, Operation & Maintenance Guide

INSTRUCTION MANUAL HAND HELD STEAM CLEANER JQ688A-1

ProMoss TM Plant-Based Water Treatment Solves Problems in Tobacco Manufacturing Plant Air Washer Systems

ARTESIAN 220 & 340 Instantaneous Indirect Water Heater By Dunkirk Boilers INSTALLATION AND OPERATING INSTRUCTIONS ENGINEERING MANUAL

Section 1. Information before installation

Maintenance page 14 Guarantees page 15 BIO-UV Range DESCRIPTION UV10 UV20 UV30 UV40

APEX Water Filters MODEL RO 5. Treat your body to pure goodness with Apex filtered water INSTRUCTION MANUAL. pure water in every drop

HYDRAULIC OIL COOLER. Installation, Operation & Maintenance Guide

PASSIVE HEAT EXCHANGER ANTI-FOULING FOR SOLAR DHW SYSTEMS

J-PRO-22 Pump Proportional Feed Chlorinator Installation & Start-Up Guide

How about Savings in Time, Money, Energy and Longer Life?

HydroBlend TM Water Treatment Product Characteristics

MKTF CRO-Series 5-Stage Reverse Osmosis System Installation and Maintenance Manual

Web:

Operating and assembly manual: Electric instantaneous flow heater Admiral

IDL / De Longhi Appliances via Seitz, Treviso Italia

Serpentine water heater. Instruction manual

AQUAS POOL PACKAGE INSTALLATION INSTRUCTIONS FOR MODELS: OXN 400/ /802 AQUAS Pool Package

Please take time to carefully read through these guidelines before using your Kamco pump.

Installation, Operation and Maintenance Instructions for Thermax Semi-Storage Calorifier

ERGOMAX 7 INSTALLATION

Please take time to carefully read through these guidelines before using your Kamco pump.

Magnetic-Inductive Flow Velocity Sensor PIT. Device Description

INSTALLATION AND OPERATION MANUAL STEAM COIL BASE CONVECTION STEAMER MODEL SCX-16

Installation Manual. Instrucciones de instalación y manual de usuario 1

TECHNICAL MANUAL ASGX

TEMPLATE ASSISTED CRYSTALLIZATION. Presented By Ryan Lessing 11/13/2014

IDL/ De Longhi Appliances via Seitz, Treviso Italia

ELECTRIC WATER HEATER INSTALLATION & OPERATING INSTRUCTION MANUAL

Service Bulletin: TrueSTEAM Installation Best Practices Remote Installation Plumbing and Draining Water Quality

Solar water heating system

Installation & Service Guide

Frequently Asked Questions

OWNER S MANUAL. Models: AC110, AC125, AC150 made from 2003 through Proudly Made in the USA

Colt CoolStream Adiabatic Cooling & Ventilation System

Closing procedures for above-ground pools

MIXED INDUCTION / HI-LIGHT VITROCERAMIC HOB MH-F3BS

IRRIGATION EQUIPMENT LTD. The Perfect Solution for Water Filtration and Irrigation Problems

MODEL NO RUSSELL HOBBS APOLLO 1.8L DIGITAL FILTER COFFEE MAKER

O Pro electric storage water heater

Submersible Garden Pump USER'S MANUAL

OPERATING INSTRUCTIONS with safety features

How to care for your water storage tank

MONSTER FLOOR (SC1Z1) INSTRUCTION MANUAL. CUSTOMER SERVICE: (AUS) (NZ) Model #: SC1Z1 AUS, NZ

PIPING APPLICATION GUIDE

Residential Application

FULL RANGE of products for the protection of boilers and water heating loops SLUDGE FILTERS FDM-1P / FDM-2 / FDM-3

Please take time to carefully read through these guidelines before using your Kamco pump.

CLEAN WATER PUMP. MODEL No: Hippo4A OPERATION & MAINTENANCE INSTRUCTIONS. Part No:

Installation and operating manual of water boiler.

Section 2. Product overview & label familiarisation

Seaward Products OWNER S MANUAL WATER HEATERS. Serial Number:

Register your product and get support at. AC4076. User manual

Clyde Alkon 90. Floor standing condensing boilers. Natural Gas. 90 kw. LP Gas. 90 kw

WATER BOILER METOS MARINE WKI MG MW,

Chiller Tube Cleaner Buying Guide

ELECTRIC WATER HEATER HT382E55

SuperStor Glass Lined Storage Tank

INSTALLATION and OPERATION MANUAL DIRECT STEAM KETTLES MOUNTED ON ELECTRIC BOILER BASE CABINET MODELS: EMT-6 EMT-10 EMT-12 EMT-6-6 EMT-10-6 EMT-10-10

AQUAS POOL PACKAGE INSTALLATION INSTRUCTIONS FOR MODELS: XPN 400/ /802 AQUAS Pool Package

Transcription:

PHYSICAL TREATMENT DEVICES RECOMMENDATIONS FOR INSTALLATION POWEL s.r.o., Moyzesova 43, 080 01 Presov, Slovak republic, EU tel./fax: +421 51 7562171, e-mail: powel@powel.sk, www.powel.sk

CONTENTS Page water treatment units 3 General principles 3 Water treatment in family houses 3 Treatment of water from your own well 3 Treatment of water from municipal water supply system 3 Water treatment in hot water heating systems in family houses 4 Treatment of domestic hot water () 4 One-stage and two-stage flow heating of domestic hot water 5 Combined flow and accumulation heating 5 Accumulation heating of domestic hot water 5 Accumulation heating of domestic hot water using flow heater 6 Accumulation heating (stage 1) combined with flow heating (stage 2) 6 Water treatment for steam boilers 7 Small steam boilers 7 Medium-capacity steam boilers 7 Example of water treatment for medium-pressure boilers of 25 MW installed capacity 7 Water treatment in hot water heating systems 8 Water treatment in small systems 8 Water treatment in larger systems including several boilers 8 Water treatment in swimming pools 9 Where to obtain further information? 9 2

water treatment units General principles When considering water treatment using equipment you should keep in mind several general principles that altogether apply to various systems: For the treatment process also employed by units it is more convenient if the particle velocity of treated water is higher at the point of treatment, i.e. it is suitable to reduce the pipe diameter at the point of treatment if possible. It is important to treat water when it is cold or prior to heating. For this reason the point of water treatment should be located before the point of water heating. Owing to certain degradation of the positive water treatment effect due to mechanical shocks and turbulence, the point of water treatment should be located behind a pump, separator or flow meter, and as close to the point of heating as possible. Do not forget that the effect of this method of water treatment is temporary only the treated water retains its properties for the period of 72 hours (depending on the chemical composition of water, on the system and its individual components, pressure, etc.). Note that the water treatment reduces creation of incrustations in amorphous form (incrustations are not solid but muddy or slimy), however, the incrustations form after heating, especially, in the places where the particle velocity is low or close to zero. Therefore, it is necessary to equip the devises, in which muddy incrustations settle, with an efficient desludging unit (boilers, heat-exchanges, accumulation heaters, storage tanks, etc.). Unless the system (especially, closed systems) is equipped with a desludging unit, it is necessary to include such equipment into the system (e.g. a centrifugal separator or desludging filter). With respect to the occurrence of muddy incrustations it is necessary to insert pumps in the flow direction behind the centrifugal separator or a suitable desludging filter to avoid the risk of damage. When treating water of up to 90 C and hardness over 20 N, it is recommended to use a plastic insert in the place of coil installation - a KZ, KP (Descaler KZ, KP - plastic pipe with threads or flanges (KP) and wrapped coil). The piping at the point of treatment should be completely filled with water. If any air is sucked in or if the water has gasses it is recommended that degassers are used before the treatment. In the systems where the volume of refilling water is lower than twice the value of the total water volume in the system, e.g. in the domestic hot water systems, the treatment of circulation water is also recommended. The systems that use the treated water must be designed so that their piping and equipment enables desludging and flushing of the system. Water treatment in family houses Treatment of water from your own well When using a house water supply plant it is recommended to locate the water treatment at the point of piping between the pump, submerged pump and reservoir where the flow is either zero (pump off) or almost stabilized (pump on). If a small house water plant (ATS or the so-called Darling) is used for water supply, locate a treatment unit at the point of reservoir outlet. The selection of the unit depends on the pipe diameter (3/4 to 6/4 ). Fig. 1 KZ RESERVOIR INNER DISTRIBUTION alt. 2 alt. 1 Treatment of water from municipal water supply system In this case we install water treatment at the main connection piping that is basically 1. In such case we use the HE25 unit. Fig. 2 MUNICIPAL SYSTEM FLOWMETER KZ INNER DISTRIBUTION 3

Water treatment in hot water heating systems in family houses The manufacturers of the individual components that form hot water heating systems specify operational parameters for equipment (boilers, heat exchangers, etc.), especially, concerning the water content (ph, hardness, alkalinity, chlorides ). In most cases the requirements can be met only by chemical water treatment. However, under some conditions it is possible to reach very good results (hard incrustations on heat-exchanging surfaces do not form, defectless operation of regulation equipment ) also exclusively by employing physical water treatment or its combination with chemical water treatment the so-called additional water treatment. For successful application of physical water treatment in hot water heating it is necessary that the loss of circulation water is negligible or zero, i.e. the circulation water does not change in the system for a long time (over a year). It is common practice for plumbers to fill a new hot water heating system after completion with water that is available, i.e. untreated water. In most cases, in a short time, the regulation equipment will be jammed or will function incorrectly or even get damaged. Unless the water is extremely hard, in all cases after installing physical treatment units the above problems will be resolved. For this reason economical equipment with two outlets is popular in practice (one outlet for cold water treating, especially, the main water supply, and the other outlet for treatment of circulation water in the hot water heating system), and several plumbing companies install it to newly built systems. Hot water heating is a closed system mostly with forced circulation. According to general recommendations, locate a water treatment unit on the return piping prior to the boiler inlet. Due to the fact that small-capacity boilers are not equipped with a desludging unit and with respect to the fact that the system is closed, it is recommended to insert an element to the system in which the released incrustations will sediment. Such equipment may include various filters that are mostly installed in all heating systems but the disassembly of the filter components is required for its maintenance. In case the system does not have a filtration or sedimentation element, it is recommended to insert to the system e.g. some desludging filter or centrifugal separator. In order to avoid unwanted sedimentation of released incrustations e.g. in the boiler, it is good if the circulation water velocity is higher. Therefore, if possible, it is recommended that higher capacity circulation pumps are installed. In case the system is older and with accumulated incrustations it is necessary to place a separator at the point of the boiler inlet in order to gradually reduce incrustations as well as occurrence of separated larger fragments of incrustations by the treated water. It is important, especially, for modern boilers with small water volume and thin piping in which released softened incrustations can jam and harden on the hot surface. Fig. 3 OUTLET RETURN PIPING Treatment of domestic hot water () The treatment by the units depends on the heating technique. With respect to variable demand for hot water it is recommended for inlet water treatment to use the series of units PS. If water demand changes periodically within 24 or 168 hours (day or week) it is possible to use the series of units PS T in combination with a suitable switch clock (optional accessory). When treating water of up to 90 C and hardness over 20 N, it is recommended to use a plastic insert in the place of coil installation - a KZ, KP (Descaler KZ, KP - plastic pipe with threads or flanges (KP) and wrapped coil). In case the outlet does not have a storage tank for or it does not have a desludging unit it is recommended to install an desludging filter or centrifugal separator at the outlet. In case of using flow heaters it is necessary to connect the circulation inlet to the heater water inlet in order to maintain some minimum flow through flow heaters when the demand for is zero. In such cases it is recommended to use higher capacity circulation pumps in the circulation circuit. In case the existing system does not enable to increase the flow in the circulation piping it is necessary to place an additional circulation pump to the system (the broken line in Figure 5), that will be put in operation in case the demand for falls under a preset value. This solution will provide a permanent flow through the heater and will avoid depositing of muddy sludge in the heater, and will move sludge to the places where we expect it tank or separator. In case of multi-stage heating it is convenient to regulate heating at individual stages evenly to avoid the socalled thermal shocks of heated water due to excessive heating at one stage this is especially critical at the flow 4

One-stage and two-stage flow heating of domestic hot water It is recommended to use a desludging filter or a centrifugal separator in the circulation circuit, which especially applies to older (partly incrusted) systems because it removes incrustations released from the system by the effect of circulating treated water. Fig. 4 alt. TANK KP (KZ) STAGE ONE STAGE TWO CICULATION T Combined flow and accumulation heating Figure 5 shows the above-mentioned solution for continuous minimum flow at the stage one (flow water heater) that tends to be more liable to incrustations than accumulation heating. This solution can also be applied to other treatment methods. In all the cases it is necessary to ensure regular desludging of filters, separators, tanks or heat exchangers. Fig. 5 STAGE TWO Q < Q MIN KP (KZ) STAGE ONE T Accumulation heating of domestic hot water With respect to high capacity of accumulation heaters that plays the role of a sedimentation element and is equipped with efficient desludging unit (tap cock), no separator is necessary either at the outlet or the circulation circuit. Fig. 6 CIRCULATION KP (KZ) T 5

Accumulation heating of domestic hot water using flow heater The accumulation heating is implemented by the circuit with a flow heater and accumulation tank equipped with a desludging unit. In order to ensure continuous minimum flow by a flow heater the circulation circuit is connected to the flow heater inlet. For this reason it is necessary to protect the flow heater from released particles of incrustations by a desludging unit in the circulation circuit. Similarly to the previous case the storage tank thanks to its volume plays the role of a sedimentation element at the outlet. Fig. 7 KP (KZ) CIRCULATION T Accumulation heating (stage 1) combined with flow heating (stage 2) Stage one is accumulation heating using a flow heater and storage tank that thanks to its volume plays the role of a sedimentation element. From this tank the muddy incrustations are taken out during desludging. Stage two is flow heating of which inlet is connected to the circulation circuit. In case of absence of a storage tank at the outlet of stage two it is necessary to locate a desludging unit there. The reason of placing desludging unit in the circulation circuit is the same as above. Fig 8 STAGE TWO STAGE ONE CIRCULATION KP (KZ) T 6

Water treatment for steam boilers Relevant technical regulations specify the water composition for supply and additional water in steam boilers. For this reason it is necessary to understand the water treatment as additional, even if there are units placed to steam boilers, where without using any water treatment the steam boilers operate to full satisfaction of their operators. Our company also offers units for chemical water treatment. We will be glad to help you select them. Small steam boilers Small steam boilers have a separate inlet for condensate and for additional supply water. Depending on boiler capacity and the volume of used steam also the flow of supplied additional supply water changes. For these applications the following units are appropriate: HE, or PS T. It is necessary to desludge the boiler regularly. Fig. 9 CONDENSATE STEAM STEAM Medium-capacity steam boilers Figure 10 illustrates the method of water treatment for steam boilers of capacity over 1 ton/hour as well as for single inlet steam boiler (supply water inlet), where the additional water first mixes with the condensate and after desludging filter (centrifugal separation) it is treated. A desludging unit is required because released incrustations can be transported by the condensate to the inlet. Fig. 10 CONDENSATE STEAM STEAM Example of water treatment for medium-pressure boilers of 25 MW installed capacity Since water treatment for high capacity steam boilers requires individual approach this manual cannot present a general scheme. It rather gives an example of water treatment for medium-pressure BK 8 boilers of the total installed capacity of over 25 MW. In case of the solution for water treatment for steam boilers of similar capacity it is recommended to consult the suitable method of water treatment by units. The system shown in Figure 11 makes use of the original water treatment system, particularly, a reactor that functions as a sedimentation element, sand filters, decarbonised water tank and supply water tank. The feeder of polyphosphates remained as the only elements from the original system of chemical treatment in order to reduce the apparent alkalinity of supply water. Fig. 11 PRE-HEATING REACTOR CONDENSATE FEEDER OF POLYPHOSPHATES DEGASSER TANK SAND FEEDER OF POLYPHOSPHATES PK 1 PK 1 DECARBONISED TANK 7

Water treatment for hot water heating systems When using physical water treatment in large hot water heating systems it is necessary to follow a similar procedure for water treatment to the one shown in chapter Water treatment in hot water heating systems in family houses. For water treatment in closed systems it is necessary to (due to the fact the method is time restricted (about 72 hours)) to place the units in the circulation part thanks to what the treatment effect of the circulation water continuously maintains. Even though it seems to be groundless, based on our experience it is also recommended to treat also the addition water to the system especially in the cases when there are quite big losses of the water in the circulation system. Fig. 12 OUTLET RETURN PIPING Water treatment in small systems Even though the boiler is equipped with desludging it is recommended for the boilers of a small volume of heated water (flow) to put a desludging filter or centrifugal separator to the return piping because of protection of the boiler from released bits of incrustations. For higher volume boilers (accumulation) it is possible to leave the separator out the released incrustations will be desludged in the boiler. Fig. 13 Water treatment in larger systems including several boilers 1 Time effect of this treatment method is of considerable advantage in this case. With respect to the total volume of water in the system and capacity of circulation pumps it is possible to place a water treatment unit at the return piping of one of more boilers Alt. 1 (the one that is continuously in operation) or at one of return piping connected to the water-collecting header Alt. 2. For such method it is recommended to take into consideration the calculation that the total volume of water in the system should flow through the point of treatment at least once in 24 hours. Another possibility includes artificial closing of the heating circuit through a reduction valve, desludging unit (for higher water hardness or water losses in the system) and through the treatment itself. In all the alternatives it is possible to obtain a sufficient water treatment process for economically lower costs. It is important to make sure the boilers or filters used are regularly desludged. The treatment of additional water is recommended for higher water losses in the system. Heat exchangers have similar water treatment procedure to boilers. alt. 1 2 3 alt. 2 alt. 3 8

Figure 14 shows another possibility of water treatment in closed systems. The desludging filter is placed in the main return piping and the treatment is applied only to the piping of some suitable diameter. The selection of the diameter depends on the total flow Q and the amount of water in the system. Fig. 14 DN(1) S1 Q1 S DN Q S = S1 + S2 WITH DN(2) S2 Q2 3 3 Q2 [m ] > total water volume in the system [m ] / day Water treatment in swimming pools In addition to anti-incrustation effects, the water treatment in swimming pools also involves antibacterial effects, what will result in lower chlorine consumption (by 30%) and consequently improve the quality of pool water. The electromagnetic water treatment distorts bonds of incrustation-forming substances to water molecules, a small amount of hydrogen peroxide is formed and quickly dissolves in water and kills bacteria. It also forms a Fe3O 4 layer on the inner surface of piping which protects steel surface from corrosion. Fig. 15 HEATING POOL DN 150 DN 150 VALVE DN 65 DN 150 KP (KZ) DN 65 DN 65 DN 65 Figure 15 illustrates an example of water treatment in a swimming pool. In the normal swimming pool operation always only one steel pump, slide valve, is closed and all the water is treated. The so-called filter washing is usually performed once a week, when using the valves the flow direction through the filter changes. When washing, all the pumps are on in order to create necessary excess pressure and to get the pressure loss as low as possible, also a slide valve will open and as a result the water does not flow through the point of treatment. Because the entire process of filter washing takes about an hour, the water treatment in the swimming pool is not interrupted. At relatively low costs this solution can not only stop forming incrustations and improve heat transfer for pool water heating but also to reduce forming chlorine. Therefore, the return on investment to water treatment by units will even shorten more. Where to obtain further information? Any information on the individual units and accessories as well as other methods of water treatment and the prices can be obtained at: POWEL s.r.o., Moyzesova 43, 080 01 Presov, Slovak republic, EU tel.: +421 051 7562171, fax: +421 051 7562170 e-mail: powel@powel.sk, www.powel.sk 9