M LLET. Silo pressure detector. Füllstandtechnik. Operating instructions. 1. Description. 1.5 Dimensions. 1.1 Intended use. 1.

Similar documents
Manual Isolating Barrier D461R1 (Revision 01)

Manual Isolating Barrier D461 (Revision 05)

Hazardous Location Heaters. Thermostat INSTRUCTION MANUAL

Physikalisch-Technische Bundesanstalt

Operating Manual MS220Vi and MSR220Vi

Operating Manual MS220VA and MSR220VA

Instruction Manual Captive Air Level Control. Model NLP

The CE Marking Access to the European Market

Manual Power relay SR853

OPERATING INSTRUCTIONS. for the heat press. Secabo TPD7

OPERATING INSTRUCTIONS. for the heat press. Secabo TC D7

INSTRUCTION MANUAL (ATEX / IECEx)

MANUAL. for heat presses. Secabo TC5 and TC7

Smart encoders & actuators

OPTIBAR DP 7060 Supplementary Instructions

OPERATING INSTRUCTIONS. for the heat press. Secabo TCC

User manual. Explosion-safe window air conditioning system Type series AR-054. II 3 G Ex ic nac h IIC T3 Gc

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

Manual OW Caution:

Operating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA

MANUAL. for heat press. Secabo TC2

ATM Lighting sp. z o.o

Technical Data. General specifications. Rated operating distance s n 5 mm

Supplementary Installation and Operating Instructions. Category II2G

Hazardous Location Heaters. 50W and 80W Models INSTRUCTION MANUAL. Rev. I 2018 nvent P/N

OPERATING MANUAL RAY-NC 1000 SERIES

Circulation heaters for ATEX/IECEx hazardous areas or in non-atex version

OPERATING INSTRUCTIONS. for the heat press. Secabo TPD12

manual addendum DELPHI Ex

Operating Manual Distribution box

ANNEX GD-CERT-EX-EN SIT

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

Operating Instructions TSF 010. Power Failure Venting Unit PM BNE/L (0007)

Dual certification! Air handling units for potentially explosive atmospheres

OPTIBAR P 1010/2010 C Supplementary instructions

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

Technical Data. Dimensions

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 218

Translation of the assembly instructions with operating instructions and technical appendix

INSTRUCTION MANUAL (ATEX / IECEx)

Flameproof Manual Call Points Series MCP

Multipoint temperature sensor

Installation manual surface mounting plugs and socket outlets, panel mounting plugs and socket outlets with screw connection (16/32 A)

Regulated Ex-Heater HEX with internal controller, HEX with external controller II 3 G II 3 D

Immersion heaters for ATEX/IECEx hazardous areas or in non-atex version

Inductive slot sensor

Operating instructions For Vibration level switch. Model NSV

Installation manual extra-low-voltage socket outlets for panel- and surface-mounting

TRASCO ATEX Couplings

Temperature Sensor TRG Original Installation Instructions English

Installation manual surface mounting plugs and socket outlets, panel mounting plugs and socket outlets QUICK-CONNECT (63 A)

Level Electrode NRG NRG Original Installation Instructions English

1592P01. for liquids in piping DN

Drive systems for the chemical, oil and gas industry. Electric drives and systems

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version

PIT UMF2 (B) Magnetic-Inductive Flow Velocity Sensor. Operating Manual. Page 1 of 14

INSTRUCTION MANUAL (ATEX / IECEx)

Junction boxes control boxes THU 93.1 THU 93.6 THU 94.1 THU 94.9 PTB 98 ATEX March 1999

ATM Lighting sp. z o.o

A6 Safety Monitoring Device

4) Intrinsic Safety Certification

CTC EcoMiniEl. Installation- and Maintenance Manual. External electric boiler. Providing sustainable energy solutions worldwide

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

DICTATOR Hold-Open Systems for Hazardous Areas

Flameproof Manual Call Points

AD.3.XG... Atex directive ch. I Page 22 Atex classification ch. I Page 23. Tab.1 Assembly ch. I Page 25

OPTIWAVE X500 Supplementary Instructions

GTF 103-Ex. GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26. Temperature Probe for potentially explosive atmospheres

INSTRUCTION MANUAL (ATEX / IECEx)

Operating Manual MS220DA

SCHMIDT Flow Sensor SS Ex - Supplementary instructions for use in explosive atmospheres ATEX

Level Electrode NRG Original Installation Instructions English

SAFETY INSTRUCTIONS. euromotori. Safety Instructions electric motors LEX series

Sensor module. Operating instructions. Sensor module, Type 17-51P2-... Document No P2-7D0001 Version: 17 May 2011/Rev. 0

Conductivity Electrode LRG Original Installation Instructions English

INSTRUCTION MANUAL (ATEX)

Safety. Operating instructions Pilot burners ZAI, ZKIH DANGER. Contents WARNING CAUTION. Changes to edition Elster GmbH Edition 09.

Flammable gases Detectors. Model DAX 03F DAX 03F- C DAX 03F- H. Note for installation, use and maintenance. Version 1.2

NRG NRG NRG NRG

INSTRUCTION & SERVICE MANUAL

TRG 5-53 TRG 5-54 TRG 5-55 TRG 5-57

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

Betriebsanleitung / Operation manual. Druckwächtereinheit QUINGUARD / Pressurization Controller QUINGUARD

Operating Instructions

ExDetector HC-100. Data Sheet. Gas Measuring and Alarm Systems

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

ATEX Safety Switches. More than safety.

Safety instructions VEGAPULS 64

Frost Protection Thermostat

Gas cylinder scale Model GCS-1

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

EU DECLARATION OF CONFORMITY

L+T GASETECHNIK. Klöpper-Waldmann GmbH & Co. K G. Alarm unit LSG4

GESTRA Steam Systems BK 15. Installation Instructions Steam Trap BK 15, DN 40-50

EU Declaration of Conformity

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories

VERSAFLOW VORTEX Supplementary instructions

Transcription:

Operating instructions 1. Description 1.1 Intended use The pressure detector controls as limit switch the overpressure in silos and vessels. 1.5 Dimensions 1.2 Function If the pressure reaches the switching point SP, the pressure detector will give a signal. 1.3 Technical data Manufacturer MOLLET Address Industriepark RIO 103 74706 Osterburken Name Type MSDA. F1. Bulk good temperature 25 C... +80 C Ambient temperature 20 C... +70 C Signal contact Capacity of the contact Switching voltage Switching point Overpressure safety Cable connection Cable entry changeover contact, potentialfree 4 A / 250 V AC 24 V... 250 V AC or 12 V... 125 V DC 40 mbar = 0.04 bar = 400 mm WS up to 0.5 bar Scrwe M4 Cable gland M20x1.5 Type of protection IP66 acc. to DIN EN 60529 Weight Maintenance Mounting position 1.2 kg none vertical, ± 5 inclination 1.4 Material Housing Aluminium or stainless steel 316 Flange Aluminium or stainless steel 316 Ti Membrane Stainless steel 304 Flange socket Steel 1.6 Accessory (Option) Flange socket MOLLET D74706 Osterburken Tel. +49 6291 64400 Fax +49 6291 9846 Operating instructions 04/13 MSDABA

2. Installation MSDA 3. Utilization 2.1 Preparation Check the membrane of visual transport damage. Read and follow the safety instructions and the operating instructions, before handling with the device! 2.2 Mounting in the vessel Weld the flange socket (as a option) vertical (Flange is horizontal) in the silo top. Position the pressure detector (Flange is horizontal) with the gasket at the provided flange or flange socket and fix it with 4 washers and screws M8. 3.1 Commissioning Put the pressure detector into operation only, if the installation in the silo or vessel and the electrical connection have been done correctly. 3.2 Normal operation Use the pressure detector in its intended application only. Comply with the specifications on the data plate. Damaged devices have to put out of operation immediately. The pressure detector must not be modified. If there is any modification, the warranty of the manufacturer will be, cancelled. 2.3 Electrical connection Circuit diagram C 1 NO 3/4 NC 2 40 mbar P 008AP00 [ PE 1 3/4 2 3.3 Inexpert handling Ignoring of the safety instructions and the operating instructions. Not intended use. Modification at the device or of the switching point adjusting. Violation against applicable law and standards. 4. Maintenance and servicing 2.4 Cable gland After electrical connection, tighten the cable gland. Screw the cap nut, until the cable entry is closed tightly. 2.5 Cable run Run the connection cable in a way that no traction can occur at the pressure detector. 4.1 Maintenance In case of intended use, the silo pressure detector needs no maintenance. 4.2 Servicing The servicing of the pressure detector may be carried out by the manufacturer only. 2.6 Switching point The switching point is adjusted at 40 mbar. A modification may be carried out by the manufacturer only. 0080701 5. Storage Store the pressure detector dry and dustfree. Protect the membrane from damage. 6. Disposal The pressure detector can be recycled. The disposal applies to the valid environmental guidelines according to the location of the carrier and the local manufacturing conditions. 02 MSDABA 04/13 by MOLLET Operating instructions MOLLET D74706 Osterburken Tel. +49 6291 64400 Fax +49 6291 9846

MSDA Dust Explosion protection information and supplement to the operating instructions Type plate details Dust Manufacturer and address CE sign with the number of the "Notified Body" which is involved in the production control phase Model designation Dust marking Ambient temperature (Operation temperature) Vessel pressure (tested pressure) Tel. +49 62 91 64 400 MSDA1F1AB1 Typ II 1/2D Ex ta/tb IIIC T 80 C W 25 C Ta +80 C / 20 C Ta +70 C p 0,08bar...+0,08bar Stück Nr. 1234567890 01/11 AuftragNr. 1234567890 Industriepark RIO 103 D74706 Osterburken C 0044 IBExU06ATEX1069 IP66 NO NC Contact 4 A 240 V ~ oben top arriba haut ECtype examination certificate number Type of protection Connection diagram Details to loadability of signal contact Month and year of delivery Unique serial number Number which the order was handled Competence in explosion protection MOLLET D74706 Osterburken Tel. +49 6291 64400 Fax +49 6291 9846 Explosion protection information 04/13 by MOLLET MSDAEI01 01

MSDA Marking in accordance with ATEX 95 and DIN EN 600790:2009 for use on the boundary from zone 20 to zone 21. Equivalent to Directive 94/9/EG (ATEX 95) Equipment group II = everything except mining Equipment category Category 1 for zone 20, 21 and 22 Category 2 for zone 21 and 22 / = s, which are installed on the boundary between different zones Type of explosive atmosphere D = Dust the Ex symbol according to DIN EN 600790 t = Protection by enclosure a = device with very high protection standard.... for zone 20, 21 and 22 b = device with high protection standard........ for zone 21 and 22 IIIC for flammable conductive dust, flammable nonconductive dust and flammable fibres and flyings T.. C maximum surface temperature WII 1/2 D Ex ta/tb IIIC T80 C for use in zone 20. Equipment category Category 1 for zone 20, 21 and 22 WII 1 D Ex ta IIIC T80 C 02 MSDAEI02 04/13 by MOLLET Explosion protection information MOLLET D74706 Osterburken Tel. +49 6291 64400 Fax +49 6291 9846

MSDA Order code B1 Marking: II 1D / 2D Dust Equipment category appropriation by zones for use on the boundary from zone 20 to zone 21. Ambient temperatures Ta The ambient temperature Ta defines the maximum operating temperature of the detectors. Inside the vessel this is process temperature (the air or the bulk goods temperature) nearby the device. maximum surface temperature T The maximum surface temperature means the hottest point at the equipment. T 80 C The device can be installed in the walls of vessels with deviating atmospheric conditions with a difference in pressure up to Dp 80 mbar at the membran. Dp = 0,08 bar...+0,08 bar Tel. +49 62 91 64 400 Typ MSDA1F1AB1 II Ex ta/tb IIIC W 1/2D T 80 C 25 C Ta +80 C / 20 C Ta +70 C p 0,08bar...+0,08bar Stück Nr. 1234567890 01/11 AuftragNr. 1234567890 Industriepark RIO 103 D74706 Osterburken C 0044 IBExU06ATEX1069 IP66 NO NC Contact 4 A 240 V ~ oben top arriba haut 0080300 Ta = 25 C...+80 C Ta = 20 C...+70 C zone 20 zone 21 Order code B2 Marking: II 1D Dust Equipment category appropriation by zones for use in zone 20. Ambient temperatures Ta The ambient temperature Ta defines the maximum operating temperature of the detectors. Inside the vessel this is process temperature (the air or the bulk goods temperature) nearby the device. T 80 C maximum surface temperature T The maximum surface temperature means the hottest point at the equipment. Tel. +49 62 91 64 400 Typ MSDA1F1AB2 II Ex ta IIIC W 1D T 80 C 20 C Ta +70 C p 0,08bar...+0,08bar Industriepark RIO 103 D74706 Osterburken C 0044 IBExU06ATEX1069 IP66 NO NC z o n e 20 Ta = 20 C... +70 C Dp = 0,08 bar...+0,08 bar The device can be installed in the walls of vessels with deviating atmospheric conditions with a difference in pressure up to Dp 80 mbar at the membran. Stück Nr. 1234567890 01/11 AuftragNr. 1234567890 Contact 4 A 240 V ~ oben top arriba haut 0080301 MOLLET D74706 Osterburken Tel. +49 6291 64400 Fax +49 6291 9846 Explosion protection information 04/13 by MOLLET MSDAEI03 03

MSDA Special conditions and instructions for safe application 1. The installation, maintenance, initial operation, removal and repair have to be controlled resp. checked by an authorized person for explosion protection. 2. For the electrical connection you have to take notice of the local and statutory requirements and/or the VDE 0100. 3. Take notice of the specifications on the data plate. 4. A fuse (with max. 4A) has to be connected in series to the voltage supply. 5. Protect the signal contact from voltage peaks when inductive loads are connected. 6. As soon as the device will be brought into the explosion hazardous area it has to be mounted immediately at the precaused place and a cable has to be brought into the cable gland. 7. Using the device in ambient temperatures > +60 C, the applied connection cables have to be made for temperatures of min. +80 C. 8. The cable gland and the plug screw were screwed and protected at the factory. Please check if they have loosened during on the mounting or at the transport. When it is loosened, it has to be fitted again. 9. To secure the type of protection, the screw nut of the cable gland has to be fixed at the installation with a torsional force of min. 5.0 Nm. ATTENTION! If it will be fastened too strong, the IPprotection can be affected. 10. The earth connection of the device has to be installed in such a way that mechanical damage will be excluded. 11. The device may put into operation with intact capsealing and when it is closed, only. 12. Switch off the power supply, before opening the device. (touchdangerous voltage) 13. Using the in the silo wall under deviating atmospheric conditions the maximum differential pressure has not to exceed 80 mbar and the working temperature has not to exceed +80 C at the membran. 14. In case of existing combustible dusts with a minimum ignition energy less than 3 mj or with a minimum ignition temperature under +300 C (BAM assessment), the parts in contact with the dust must be made of stainless steel. 15. Take notice of the requirements of DIN EN 6007914, DIN 6007917 and DIN EN 11271, especially regarding the dust deposits and temperatures and follow the pertinent rules and regulations. 16. ATTENTION safety device! Don t modify anything at the device or at the switching point adjusting! _ 04 MSDAEI04 04/13 by MOLLET Explosion protection information MOLLET D74706 Osterburken Tel. +49 6291 64400 Fax +49 6291 9846

t EUKEMSDA Index 1 Seite/Page 1 von/of 1 EUKonformitätserklärung EUDeclaration of Conformity Wir/ We MOLLET Industriepark RIO 103 D74706 Osterburken Tel. 06291 64400 Fax 06291 9846 erklären in alleiniger Verantwortung, dass das Produkt: declares under our sole responsibility, that the product: SiloDruckmelder / Typ/Type MSDA... den folgenden Europäischen Richtlinien entspricht: conforms with the following European directives: Niederspannungsrichtlinie Low voltage directive 2014/35/EU Angewandte harmonisierte Normen oder normative Dokumente: Applied harmonized standards or normative documents: EN 610101:2010 EN 60529:1991 + A1:2000 + A2:2013 Und die Geräte mit Kennzeichnung entsprechen zusätzlich der folgenden Europäischen Richtlinie: And the devices with marking conform additional with the following European directive: ATEXRichtlinie ATEX directive 2014/34/EU Je nach Ausführungsvariante angewandte harmonisierte Normen oder normative Dokumente: Depending on the design applied harmonized standards or normative documents: EN 600790:2012 + A11:2013 EN 6007911:2012 EN 6007926:2015 EN 6007931:2014 EGBaumusterprüfbescheinigungsnummer: EUType Examination Certificate: IBExU06ATEX1069 Ausgestellt von:. Issued by: IBExU Institut für Sicherheitstechnik, 09599 Freiberg (0637) Qualitätssicherung: Quality assurance: TÜV NORD CERT, 30159 Hannover (0044) n e k r u rb e s O 6 70 4 MOLLET ExB H 7 D H b m G F ü ll s ta n d t e ch n ik Osterburken, den 10.05.2016 Wolfgang Hageleit Geschäftsführer / managing director Diese Erklärung darf nur unverändert weiterverbreitet werden. This declaration is only allowed to hand out in unchanged form. 91_EUKEMSDA_1_0516

00 00BA00 03/12 by MOLLET Operating instructions MOLLET D74706 Osterburken Tel. +49 6291 64400 Fax +49 6291 9846