Comparison of Heating Efficiency of a Heat Pump to Electric Heating Panels

Similar documents
Air Conditioning Inspections for Buildings Efficiency of Air Conditioning Systems

SECTION 8 AIR SOURCE HEAT PUMPS UNIT 43 AIR SOURCE HEAT PUMPS

Applications of Thermodynamics: Heat Pumps and Refrigerators

DEFROSTING METHODS Adapted from material originally provided by Kenneth S. Franklin, C.M., Director of Service, Hussmann Corporation

BASIC HEAT PUMP THEORY By: Lloyd A. Mullen By: Lloyd G. Williams Service Department, York Division, Borg-Warner Corporation

GLOBAL PROPERTY INSPECTIONS TECHNICAL BULLETIN August 1, 2002

PRESSURE-ENTHALPY CHARTS AND THEIR USE By: Dr. Ralph C. Downing E.I. du Pont de Nemours & Co., Inc. Freon Products Division

MSP WRAP-AROUND MULTIPLE SMALL PLATE DEHUMIDIFICATION TECHNOLOGY VS. CONVENTIONAL DEHUMIDIFICATION IN DEDICATED OUTDOOR AIR SYSTEMS (DOAS)

Geothermal Heat Pump Systems

Executive Summary. Number of Low Number of High Number of Faults , Number of OK

A/C-HEATER SYSTEM - MANUAL

Environmental Control in Poultry Laying Houses

Sustainable Techniques in Refrigerated Space

Chillers, air and water cooled, featuring centrifugal compressors with magnetic levitation, from 200 to kw

Fundamental Principles of Air Conditioners for Information Technology

Carnot. 2. (a) Discuss the advantages of the dense air refrigeration system over an open air refrigeration system?

9. ENERGY PERFORMANCE ASSESSMENT OF HVAC SYSTEMS

Small Commercial Business Energy Audits. Recognizing and addressing the special requirements of the small business market segment.

To accomplish this, the refrigerant fi tis pumped throughh aclosed looped pipe system.

Chapter 9. Refrigeration and Liquefaction

SECTION 9 DOMESTIC APPLIANCES UNIT 47 ROOM AIR CONDITIONERS

Dehumidification: Energy Efficiency Comparisons

Experiment 2: Test on Domestic Refrigerator for evaluation of EER.

Refrigerator and Heat Pump Objectives

Keep your electricity bill cool this summer

AHRI 920 Performance Rating and Comparisons of DX-DOAS Unit Efficiency

RSES Technical Institute Training Manual 2 72 hours, 72 NATE CEHs, 7.2 CEUs

Air Conditioning Inspections for Buildings Efficiency of Air Conditioning Systems

3. (a) Explain the working of a rotary screw compressor. [10] (b) How the capacity control is achieved in refrigerant compressor?

Efficiency of Non-Azeotropic Refrigerant Cycle

Unofficial Translation

AIR TO AIR HEAT PUMP SYSTEM DESIGN

How Air Conditioners Work by Marshall Brain

ENERGY SAVINGS THROUGH LIQUID PRESSURE AMPLIFICATION IN A DAIRY PLANT REFRIGERATION SYSTEM. A. Hadawey, Y. T. Ge, S. A. Tassou

Adsorption Chillers Energysmart Green Cooling

SECTION 5 COMMERCIAL REFRIGERATION UNIT 21 EVAPORATORS AND THE REFRIGERATION SYSTEM UNIT OBJECTIVES 3/22/2012 REFRIGERATION

Chapter 11. Refrigeration Cycles. Study Guide in PowerPoint

June 2001 / BULLETIN Way Valves. The right solenoid valve for any job.

Interim Report for the Period thru February 15, 2018 Submitted to Department of Business and Professional Regulations Office of Codes and Standards

Design and Operation of a Conditioning Energy Recovery Ventilator (CERV) for Passive Houses

VARIABLE HEAT RECOVERY IN DOUBLE BUNDLE ELECTRIC CHILLERS. Richard J Liesen 1, Rahul J Chillar 2 1 University of Illinois at Urbana Champaign

REFRIGERATION CYCLE Principles of Mechanical Refrigeration Level 2: Cycle Analysis

CARRIER edesign SUITE NEWS. Interpreting High (Low) Peak Design Airflow Sizing Results for HVAC. Equipment Selection.

R10. IV B.Tech I Semester Regular/Supplementary Examinations, Nov/Dec REFRIGERATION & AIR-CONDITIONING (Mechanical Engineering)

USER S GUIDE. For all Packaged Systems (Air Conditioners and Heat Pumps)

Energy Efficient Corn Drying. Kenneth Hellevang, Ph.D., P.E. Professor & Extension Engineer

KE2 EvaporatorEfficiency Theory of Operation

Improving and Comparing the Coefficient of Performance of Domestic Refgirator by using Refrigerants R134a and R600a

ME 354 THERMODYNAMICS LAB THE REFRIGERATION CYCLE

REVIEW ON HOT GAS DEFROSTING SYSTEM FOR VAPOR COMPRESSION REFRIGERATION SYSTEM

Experimental Research of Air Source Heat Pump Frosting and Defrosting in a. Double Stage-Coupling Heat Pump

H EDRICK ASSOCIATES OF GRAND RAPIDS West Michigan s Factory Representative

Institute of Aeronautical Engineering (Autonomous) Dundigal, Hyderabad B.Tech (III II SEM) MECHANICAL ENGINEERING

FS 231: Final Exam (5-6-05) Part A (Closed Book): 60 points

PowerPoint Presentation by: Associated Technical Authors. Publisher The Goodheart-Willcox Company, Inc. Tinley Park, Illinois

REPRODUCTION/DISTRIBUTION IS PROHIBITED. Energy-Savings Strategies for. Rooftop

Special Topics on Residential HVAC

HVAC Fundamentals & Refrigeration Cycle

Cork County Energy Agency

Refrigeration and Boil Off Compression Systems for NGL Export Facilities

Zero Net Energy Retrofit Projects The Domes Final Performance Assessment & Verification

Experimental Investigations of Different Types of Condensers on the Performance of Household Refrigerators

Pressure Enthalpy Charts

s. Properties for R134a are as follows : Saturated R-134a Superheated R-134a

Appendix 13. Categories of Cooling and Heating systems

Improving Heating Performance of a MPS Heat Pump System With Consideration of Compressor Heating Effects in Heat Exchanger Design

U.G. Student, Department of Mechanical Engineering, J D Engineering College, Nagpur, Maharashtra, India

Refrigeration and Air Conditioning

BASE LEVEL AUDIT REQUIREMENTS REFRIGERATION SYSTEMS 1. SITE DATA COLLECTION. Business Name. Site physical address (Street, Suburb, City)

Refrigeration System with a Capillary Tube and a Thermostat

Development of Boiler Design

(ME-225) HEATING, VENTILATION AND AIR-CONDITIONING SYSTEM

Water Jet Nozzle to reduce the operation cost in Air Conditioning unit

Air-Conditioning Buying Guide

WASTE HEAT RECOVERY FROM DOMESTIC REFRIGERATOR Soma A. Biswas 1, Sandeep M. Joshi 2 1,2 Pillai College of Engineering

ENERGY CONSUMPTION OF HOUSES AND LIFESTYLE IN COLD CLIMATIC AREA OF JAPAN

Oxyvap Evaporative Cooling Applications

In your home. l Regularly clean the dust off your light fixtures, lamps, bulbs, tube lights and fans.

Laboratory Evaluation of Hybrid and Advanced Water Heaters: Performance Overview in Hot Humid Climate

R4 Ventures LLC White Paper

Dhulapally, Secunderabad Subject: REFRIGERATION AND AIR CONDITIONING QUESTION BANK

Rational Use of Energy

An Experiment of Heat Exchanger Produces Hot Water Using Waste Heat Recovery from Air Conditioning

SIDDHARTH GROUP OF INSTITUTIONS :: PUTTUR Siddharth Nagar, Narayanavanam Road AUTONOMOUS QUESTION BANK (DESCRIPTIVE) UNIT I

Energy Efficiency Potential of Heat Pump Water Heaters in Commercial Buildings

MILK DEVELOPMENT COUNCIL

INTRODUCTION HVAC BASICS AND HVAC SYSTEM EFFICIENCY IMPROVEMENT SECTION O 4/19/2012

Technical Training Associates Presents. Commercial Refrigeration Equipment Servicing Part 1

Chapter 10. Refrigeration and Heat Pump Systems

Appendix A. Glossary of Common Terms

Performance Rating of Commercial and Industrial Unitary Air-Conditioning Condensing Units

HEAT PUMPS. Carrier Corporation GT72-01 Cat. No

FUEL TYPE relating to UK deaths from unintentional carbon monoxide poisoning from to

Indoor Thermal Environment of Residential Buildings in Three Cities of China

Air Conditioning System with Modified Condenser Ducts and Evaporative Cooling

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

CO 2 EVAPORATOR DESIGN

4/8/2015 Item #10D Page 1

[Third Reprint] ASSEMBLY, No. 516 STATE OF NEW JERSEY. 211th LEGISLATURE PRE-FILED FOR INTRODUCTION IN THE 2004 SESSION

ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3

Transcription:

South Dakota State University Open PRAIRIE: Open Public Research Access Institutional Repository and Information Exchange Bulletins South Dakota State University Agricultural Experiment Station 11-1-1962 Comparison of Heating Efficiency of a Heat Pump to Electric Heating Panels H. Winterfeld D. L. Moe Follow this and additional works at: http://openprairie.sdstate.edu/agexperimentsta_bulletins Recommended Citation Winterfeld, H. and Moe, D. L., "Comparison of Heating Efficiency of a Heat Pump to Electric Heating Panels" (1962). Bulletins. Paper 512. http://openprairie.sdstate.edu/agexperimentsta_bulletins/512 This Bulletin is brought to you for free and open access by the South Dakota State University Agricultural Experiment Station at Open PRAIRIE: Open Public Research Access Institutional Repository and Information Exchange. It has been accepted for inclusion in Bulletins by an authorized administrator of Open PRAIRIE: Open Public Research Access Institutional Repository and Information Exchange. For more information, please contact michael.biondo@sdstate.edu.

BULLETIN 512 HEATS COOLS Comparison of l-leating fficiency of a I-IEAT PUMP TO ELECTRIC I-IEATING PANELS AGRICULTURAL ENGINEERING DEPARTMENT AGRICULTURAL EXPERIMENT STATION SOUTH DA KOT A STA TE COLLEGE, BROOKINGS

CONTENTS Procedure -------------------------------- ------------------ --------------------------------------- 7 Description of Eq ui pmen t ---------------------------- 7 Results 9 Discussion ----------------------------------------------------------------------------------------- 11 Conclusions -------------- ----------------------------------------------------------------------------- 11 3

A portion of the funds used for this research was provided as a grant by the South Dakota Rural Electric Association, Inc. 4

Comparison of Heating Efficiency of a 1-HAT PUMP TO ELECTRIC HEATING PANELS By HAROLD WINTERFELD, Assistant Agricultural Engineer, and DENNIS L. MoE, Head, Agricultural Engineering Department For many years engineers have known that heat exists in outdoor air down to approximately-46 F. and have attempted to devise a practical means to extract this energy for use indoors. Usually when an attempt has been made to extract this energy, the same basic mechanisms and devices have been utilized as those involved with present refrigeration; that is, a refrigerant liquid is made to boil by releasing the liquid from a high pressure to a lower pressure. As it boils the refrigerant absorbs the heat. The vaporized refrigerant is then compressed by a motor-driven compressor to a higher pressure and temperature, where it condenses back to a liquid. As it condenses, the refrigerant releases heat. have the necessary controls to reverse the action to provide either heating or cooling. When controls are provided for either heating or cooling, the device is commonly called a heat pump. A heat pump can provide more heat to the heated space than the electrical energy input under favorable operating conditions. The ratio of heat output to electrical energy input is commonly called the C.O.P. ( coefficient of performance). For example, a C.O.P. of 1.5 means the heat output is 1.5 times the electrical input. The additional heat is extracted from outside air or other heat sources. Figure 1 shows the path of,the refrigerant through the reve'rsing During the past few years several valve for the cooling cycle. Figure manufacturers have introduced to 2 shows the path of the refrigerant the market air conditioners which for the heating cycle. Built-in re- 5

HEAT PUMP REVERSING VALVE DISCHARGE LINE COMPRESSOR t... _ OUTSIDE COIL COOLING CYCLE INSIDE COIL FIG. I RE VERSING VALVE DISCHARGE LINE COMPRESSOR SUCTION LINE OUTSIDE COIL HEATING CYCLE INSIDE COIL FIG. 2 6

Comparison of Heating Efficiency of a Heat Pump to Electric Panels 7 sistance heaters are commonly used to supply additional heat at 'colder outdoor temperatures. Several questions may be raised about the practicability of the heating feature of a heat pump. Is the heat pump as economical to operate as the ordinary air conditioner and a separate heating system? What months during the year could the heat pump be operated to the best advantage? Could the heat pump supply all the heat requirements for South Dakota conditions? Because there were so many unkp.own factors involved it was impossible to estimate the operating cost bv calculation. Therefore, the purpo;e of this study was to compare the operating efficiency of a commercially available heat pump air conditioner ( window model) with that of an electric heating panel under actual operating conditions in a single room. PROCEDURE Two methods of heating, heat pump and electric glass panel, were arranged through suitable controls and separate watt-hour meters to operate alternately, each for a 24- hour period. This gave approximately the same conditions for each method of heating during the period of this study. Switching from one heating method to the other was done each midnight, to correspond with official weather and temperature records. \Veather data were obtained from records kept by the Weather Engineering Station at South Dakota State College. The degree days used in this work were derived by taking the average of the high and low temperatures for the 24-hour period. A base of 65 F. was used to determine the heating degree days. Figure 3 shows the controls and separate meters used in the research. Research was interrupted for the 19.59-6 heating season. During the fall of 1959 the Agricultural Engineering Department moved to its new building. At this time the equipment being used for the heat pump research had to be moved from its original location to the new building. Procedure for the 196-61 heating season was generally the same?...s that for the 1958-59 work, except in 196-61 the glass panel was used instead of the built-in resistance heaters in the pump. DESCRIPTION OF EQUIPMENT The electric heating panels were typical hard glass with the conducting element on the reverse side. In the first installation three 6-watt units were mounted on the outside wall under a window. The heat pump air conditioner ( window model) was typical in appearance and size. It was rated 1 horsepower with cooling capacity of approximately 9,1 BTU's at 4 F. outdoor temperature. Features differing from an ordinary air conditioner included: ( 1) A reversing valve for the refrigerant, controlled by a thermostat in the unit, to switch from cooling to heating automatically.

8 South Dakota Experiment Station Bulletin 512 Figure 3. Control and watt-hour meters. ( 2) A defrost control which automatically switched the unit to the air conditioning cycle temporarily to melt frost built up on the outdoor coil when the unit was heating. ( 3) An outdoor thermostat which turned the compressor off when the outdoor temperature reached approximately 15 F. At the same time the thermostat turned on an 1,8-watt resistance heat unit which supplied heat as required by the room thermostat. ( 4) A smaller 1,-watt resistance heat unit, controlled by a fixed temperature thermostat that came on whenever room temperature fell below 7 F. The thermostat automatically disconnected the 1,-watt heater when the room temperature rose above 74 F. Later models by the same manufacturer omit the outdoor thermostat to turn off the compressormotor. They also omit the fixed temperature thermostat and 1,-watt heater, but substitute one larger resistance heater which is allowed to come on if the heat pump does not maintain the temperature setting of the thermostat when the outdoor temperature is below 45 F. \Nater produced in defrosting the outdoor coil is directed to the indoor side where a 2-watt resistance heater evaporates the water into the room. This has the effect of humidifying the indoor air. The amount evaporated into the room is least when outdoor temperatures are coldest and the need for humidification is greatest. For purposes of the experiment, control of both types of heating was accomplished by a wall-mounted

Comparison of Heating Efficiency of a Heat Pump to Electric Panels 9 thermostat. This was partly to produce the same room temperature by both heating methods and partly to eliminate the continuous operation of the blower on the heat pump. Intermittent operation of the blower was not nearly as objectionable to the people in the room as continuous operation. Equipment used during the 196-61 heating season was the same as that used. during the 1958-59 heating season except for a single 3,- watt glass panel unit instead of the three 6-watt glass panels. Figure 4 shows the heat pump and glass panel used. For the 196-61 season the resistance heating elements in the heat pump were disconnected. An outdoor thermostat switched operation from the heat pump to the glass panel at temperatures below 15 F. RESULTS During the heating season for 1958-59 the two heating methods were able to produce comfortable living conditions in a single room at all times, even though the building ( a relocated barracks building) was poorly constructed and not well insulated. The graph in :figure 5 gives the average consumption in kilowatt-hours per degree day from the first part of March until November. The graph in :figure 6 gives the results of the research for the 196-61 beating season. It shows the average consumption in kilowatt-hours per degree day to compare the two. heating methods. In this graph you will note that for the heat pump method part of the bar indicates the amount of kilowatt-hours per degree day the heat pump used, and the other part the amount in kilowatt-hours per degree day the heat panel used to maintain the room temperature. The total of the two represents the kilowatt-hours used in comparison to those used by the glass panel alone. The heat pump unit provided the heating requirements with less kilowatt-hours per degree day for larch, April, and May. The glass panel alone was more efficient during the colder months of November, December, January, and February. Figure 4. Heat pump ( upper half) and electric glass panel ( lower half).

.8....7.6.5 >,. 4 :.3... Q. r.2 5 J..2 i2 - - - -,- D heat panel heat pump r- r- - - r- - r- r- >,..3.8 -.7.6 O heat panel - heat pump f"s "' "" '"" "' "' - ""' K [SJ auxilary heat._ '"" "" heat pump C) cle " "" f"s '"" [\.5 - \".4 -.......... 1 :,. 2-3!..2 :,::.. - - ",-- S- t h:1 i' $:l ;s t:x:l - - I I Oct. Nov. Dec. Jon. Feb. Mar. Apr. May 19.: 6-1959 Heating Season; 7,76 Degree Days. Figure 5. Efficiency comparison of heat pump and electric glass panels. Dec. Jan. Feb. Mar. Apr. May 196-1961 Heating Season ; 6,455 Deg. Days. Figure 6. Efficiency comparison of heat pump and electric glass panels.

Comparison of Heating Efficiency of a Heat Pump to Electric Panels DISCUSSION 11 Results show that the heat pump is not as efficient as the electrical panel heating method during the cold winter season. This inefficiency would partly be explained by the fact that the blower and compressor motors on the heat pump are mounted in the outdoor air stream and the energy input to these motors is largely wasted. Also the coefficient of performance of the heat pump ( amount of heat transferred per watt input) decreases as the temperature drops. The heat pump was shut off at 15 F. when its coefficient of performance was theoretically equal to that for resistance heating. Data would seem to indicate that its coefficient of performance between the approximate temperature of 35 and 15 F. was poorer than that for the glass panel. Results indicate a possible application of the heat pump unit in conjunction with another heating system-that is, either where resistance electric heating is already in use ( using the heat pump on milder days) or where it is desired to shut down the central heating plant for a longer time during spring and fall. It would be expected that the only place where most persons would justify the cost would be where heating as well as cooling is desired. The heat pump model costs approximately 2 to 3% more than the model that does only cooling. Heating as well as cooling may be desired during the months when hot days are followed by cool evenings. The heat pump is particularly convenient during the spring and fall when it is desirable to remove the chill without starting the central heating system. It can be used in summer cottages or cabins without any other source of heat. It can be used for added-on rooms, basement and attic rooms, and offices which cannot be fully accommodated or controlled accurately with existing heating systems. CONCLUSIONS ( 1) The glass heating panel was more efficient than the heat pump during the coldest months even though on milder days, ab<)ve 15 F., it proved to be less efficient. For the two heating seasons studied the heat pump proved more efficient than the glass panels during the spring and fall. ( 2) The heat pump unit used in this study proved to be quite dependable in operation and performed well according to its design and purpose. It appears that control by a wall-mounted thermostat may be desirable in some locations to eliminate the objection to the otherwise continuous blower noise. ( 3) The heat pump air conditioner may find application in multiple occupancy buildings such as offices and apartments where central heating systems do not supply the varying temperatures desired in individual rooms. ( 4) It can serve as a supplemental heat source in homes that have a central heating system.