INSTALLATION and OPERATION INSTRUCTIONS

Similar documents
INSTALLATION AND OPERATION INSTRUCTIONS CONCESSIONAIRE PORTABLE DISPENSERS MODEL NOS.

INSTALLATION and OPERATION INSTRUCTIONS

INSTALLATION AND OPERATION INSTRUCTIONS STANDARD BACK BAR COOLERS, SELF CONTAINED MODEL NOS.

INSTALLATION and OPERATION INSTRUCTIONS

INSTALLATION and OPERATION INSTRUCTIONS

INSTALLATION and OPERATION INSTRUCTIONS

INSTALLATION AND OPERATION INSTRUCTIONS CUSTOM BACK BAR CABINET SELF CONTAINED AND REMOTE

Installation & Operation Manual

INSTALLATION and OPERATION INSTRUCTIONS

Installation & Operation Manual

INSTALLATION and OPERATION INSTRUCTIONS

INSTALLATION and OPERATION INSTRUCTIONS

(rev. 07/01/14)

Technical Manual and Replacement Parts List. f Real Freezers

DIRECT DRAW BEER COOLERS Installation, Operation and Maintenance Instructions

INSTALLATION AND OPERATION INSTRUCTIONS ARCTICPOUR ADVANCED REFRIGERATION TECHNOLOGY

L24TWS. Beverage Tower Kit Components. L24TWD Lynx Beverage Kits Model L24TWS Single Tower and L24TWD Double Tower

Refrigerators. Technical Manual and Replacement Parts List FORM NO REV H MODEL SKTTR7FW MODEL SKC1220W

Operation & Installation Manual

Preparing the Cabinet

4.9 CU.FT. BEER KEG COOLER INSTRUCTION MANUAL. Model No.: MCKC490S

Beer Keg Dispenser User s Manual

IMPORTANT PLEASE RETAIN FOR YOUR RECORDS

SERIES NAV S Display Merchandisers

(rev. 10/04/12)

INSTALLATION AND OPERATION INSTRUCTIONS ARCTICPOUR ADVANCED REFRIGERATION TECHNOLOGY

BOTTOM MOUNT REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

INSTALLATION AND OPERATION INSTRUCTIONS 4400 SERIES POWER PAKS

BACK BAR REFRIGERATION Installation, Operation and Maintenance Instructions

BOTTOM MOUNT REFRIGERATORS & FREEZERS Installation, Operation and Maintenance Instructions

USE/INSTALLATION INSTRUCTIONS VRBD/VUBD 24 W. BEVERAGE DISPENSER

Viking Use/Installation Guide

CR24 INSTALLATION INSTRUCTIONS

Technical Manual and Replacement Parts List. Mobile Freezer

INSTALLATION MANUAL. Series 322 Ice Cube Machine SPECIFICATIONS UNPACKING. Series 322 Ice Cube Machine Installation Instructions

SERIES NIM. Low Temperature Merchandisers PLEASE READ THIS MANUAL BEFORE USING THE PRODUCT

SBC490Bi(All Versions) UNDER-COUNTER FULLSIZE BEER DISPENSER

Outdoor Beer Dispensers

User Manual. Commercial School Milk Cooler User s Manual. Commercial School Milk Coolers: MC34, MC49, MC58

BOTTLE COOLERS SLIDE TOP INSTALLATION AND OPERATION INSTRUCTION MANUAL MODEL SERIES BC24- BC36- BC48- BC72- BC96-

COMMERCIAL GRADE UNDER COUNTER REFRIGERATION RANGE

Hoshizaki America, Inc.

UDD1, UDD1S, UDD2448, UDD2448S, UDD2460, UDD2460S, UDD2472, UDD2472S

SAN RAPHAEL PRESSURE LITE VITREOUS CHINA SIPHON JET TOILET

SERVICE MANUAL BEVERAGE CENTER II

InstructIon Manual KrEs EQuIPMEnt stands

INSTRUCTION MANUAL COMMERCIAL GRADE KEGERATOR MODEL:XCK-1

Glass Door Merchandiser Refrigerator and Freezer

Agency-certified for outdoor use o Stainless steel exterior cabinet surrounds unit and forms a waterresistant

INSTALLATION and OPERATING. INSTRUCTIONS for. SMZP26 Series. elf-contained Freezers

Chef Base Refrigerators

FAGOR BAR EQUIPMENT. Manual for installation, use and maintenance.

INSTALLATION INSTRUCTIONS

Hoshizaki America, Inc.

REFRIGERATED DROP-INS (2-6)FT-DI Installation and Operating Manual

ref. com Owner s Manual for models: A Step Above the Standard Thank you for choosing EVEREST

G-10f/GCG-10f UPRIGHT COOLER

OUTDOOR BEER DISPENSERS Installation, Operation and Maintenance Instructions

Sandwich/Salad Table Under-counter Refrigerator Worktop Refrigerator

GLYCOL CHILLER INSTRUCTIONS IMPORTANT: BEFORE OPERATING PLEASE SEE INSTRUCTIONS ON PAGE 5

Solid Door Top Mount Reach-In Freezer

Water Boilers ME10EN, ME15EN. Table of Contents

COUNTER TOP REFRIGERATION MODEL SERIES HUBM-2RB/HUBM-2FB/HUBM-3.5RB/HUBM-3.5FB HUBM-2R/HUBM-2F/HUBM-3.5R/HUBM-3.5F

Operation Manual and Parts Directory

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features.

GCG-10. Instruction Manual. G-Series Cooler. Manual is for the following models: GCG-10-N33EB G-10-N33EB UPRIGHT COOLER

ice provided below the model number and serial number nce. They are located on the model number plate on the FULL ONE-YEAR W_ ON BEER DISPENSER

SAFETY PRECAUTIONS Read all of the instructions before using this appliance. When using this appliance, always exercise basic safely precautions,

ICE CREAM TOPPING CABINETS REFRIGERATOR or FREEZER Installation, Operation and Maintenance Instructions

ICE MAKER Use & Care Guide. Table of Contents... 2

User Manual / Installation Instructions

Daikin Water Cooling, Heating, and High Capacity Booster Coils

Glass Washer. PERLICK Glass Washer NO ONE WORKS HARDER TO KEEP YOU COOKING. WHALEY FOODSERVICE REPAIRS ITEM PART NO. NO.

CHEF BASE CABINETS Installation, Operation and Maintenance Instructions

CHEF BASE CABINETS Installation, Operation and Maintenance Instructions

PLEASE READ THIS MANUAL BEFORE USING YOUR APPLIANCE. KEEP THIS MANUAL IN A SAFE PLACE FOR FUTURE REFERENCE.

Technical Manual and Replacement Parts List. Cream Dispenser

GENERAL LABORATORY REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

Hoshizaki America, Inc.

CC-2222C-PL, CC-2222C-PRL, CC-2222C-PR-2, CC-2222C-PL-2,

UNDERCOUNTER REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

Installation and Operation Guide For

Hoshizaki America, Inc.

Turbo Air Speed up the Pace of Innovation TBB-4SB CAUTION! PLEASE KEEP POWER SWITCH ON BEFORE OPERATING THIS EQUIPMENT

G-7s. Instruction Manual. G-Series Cooler COUNTERTOP COOLER. Part No.11IPA

English. Your Model Number is: HD1500 IMPORTANT

ELECTRIC COMPACT DECK OVEN INSTALLATION - OPERATION - MAINTENANCE

SELF-CONTAINED FLAKER

Hoshizaki America, Inc.

MERCURY HD-22 AUTOSCRUBBER Safe Operations

Installation & Operation Manual. 24" C-Series Refrigerator Wine Reserve Beverage Center

OPERATING INSTRUCTIONS

INSTRUCTION MANUAL COMMERCIAL GRADE KEGERATOR MODEL:XCK-2448/XCK-2460/XCK-2472

Model:WHS-109FB1/WHS-109FW1/WHS-109FSS1

TROUBLESHOOTING VANGUARD

Ice Cube Machine. User s Manual. Be sure the ice machine has been standing upright for at least 24 hours prior to plug-in.

Hot-1 Hot Water Dispenser

INSTALLATION INSTRUCTIONS

UNDERCOUNTER LABORATORY REFRIGERATORS and FREEZERS Installation, Operation and Maintenance Instructions

G-10s. Instruction Manual. G-Series Cooler UPRIGHT COOLER. Part No.11IPA

Transcription:

INSTALLATION and OPERATION INSTRUCTIONS MODEL NOS. DC90ACLT IMPORTANT INFORMATION To register your product, visit our web site at (www.perlick.com). Click on Commercial, then Service. You will see the link to Warranty Registration Form. You must complete and submit this form or the installation date will revert back to the ship Date. The unit comes with a one year parts warranty. This manual has been prepared to assist you in the installation of your and to acquaint you with its operation and maintenance. We dedicate considerable time to ensure that our products provide the highest level of customer satisfaction. If service is required, your dealer can provide you with a list of qualified service agents. For your own protection, never return merchandise for credit without our approval. We thank you for selecting a Perlick product and assure you of our continuing interest in your satisfaction. WARNING: When lifting, the full weight of the cabinet must be supported. Lift from the cabinet base and not from the top. Improper lifting can result in severe damage to the cabinet. Table of Contents Preparing the Cabinet for Use Specifications...2 Initial Setup...3 Electrical...3 Tapping Connecting the Keg Coupler...4 Tapping the Keg/Priming the System...4 Connecting the Regulator...5 Adjusting Gas Flow...5 CO2 Leak Test...5 Replacing a CO2 Gas Cylinder...5 Handling CO2 Gas...5 Cleaning Cleaning the Beer Lines...6 Cleaning the Cabinet...6 General Information How to Pour a Perfect Glass of Beer...7 Wiring Diagrams...8 Glycol Loop Diagrams...9 Preventative Maintenance...10 8300 West Good Hope Road Milwaukee, WI 53223 Phone 414-353-7060 Fax 414-353-7069 Toll Free 800-558-5592 E-Mail: Perlick@Perlick.com www.perlick.com

Installation and Operating Instructions Specifications, * Model Nos. DC90ACLT keg capacity 2 Keg CABINET Length Inches. (mm) 923/4 (2311) Dimensions Including Depth Inches. (mm) 261/2 (673) Bumpers Height Inches. (mm) 5513/16 (1354) condensing unit H.P. 1/3 HP Ship wt lbs. (kg) 805 (366) Interior Door sill: High strength polyethylene. Door pan and ceiling: High impact polystyrene. Walls and Floor pan: Stainless steel. exterior Stainless steel top and doors. Choice of stainless steel or galvanized back and sides. Bottom galvanized. Refrigeration R-134a expansion valve system. Epoxy coated aluminum fin and copper tube evaporator, coil. Digital temperature control. Self-defrosting. glycol mixture 1/3 propylene glycol to 2/3 distilled water. Ventilation All sides of unit must be unobstructed to ensure adequate ventilation. Plumbing Evaporator condensate and beer waste is pre-plumbed to a waste tank located in the CO2 compartment. electrical Unit is furnished with 3-prong (NEMA) 5-15 plug, 9 foot long power cord that requires a dedicated 15 amp circuit of 115 volt, 60Hz, 1 phase AC electricity. Disconnect power cord before servicing. Insulation Foamed-in-place environmentally friendly polyurethane; 2 walls, 11/2 top and floor. OPTIONS & Options: Two single faucet dispensing heads or one dual faucet head. ACCESSORIES Accessories: Keg couplers Regulators Faucet locks * This product is intended for the storage of non-potentially hazardous canned and bottled products only. R23 1/16 [586] 92 3/4 [2355] 19 7/8 [504] DOOR OPENING 18 3/4 [476] BACK OF LINER TO INSIDE OF DOOR PAN 26 1/2 [673] 12 [305] 24 1/16 [610] 14 [356] 24 [610] 44 [1118] 42 15/16 [1091] 33 [837] 91 [2311] 24 3/4 [629] 12 11/16 [322] NOTE: Shown with optional two single faucet draft arms. 10 1/2 [267] 3 3/16 [81] 8 5/8 [220] 7 1/2 [191] 43 1/16 [1094] 55 13/16 [1417] 35 9/16 [904] 27 1/2 [698] DOOR OPENING 2

Preparing the Cabinet for Use Uncrating and Inspection Remove all crating material before operating. Carefully inspect cabinet for hidden damage. If damage is discovered, file your claim immediately. Perlick is not responsible for damage in transit. Ensure that the unit is on a level surface and that the brakes on the casters are engaged. It is important that the unit is unobstructed on all sides to provide adequate ventilation for the refrigeration decks. Blocking the ventilation louvers may damage the compressor and void the warranty. Remove the bottom front grille to access the machine compartment. Connect the power cord to a separate dedicated circuit as described in the electrical section of this manual. Turn on the rocker switch labeled circulating pump and check for glycol leaks. Next, turn on the rocker switch labeled condensing unit. The flash chill heat exchangers and evaporator coil circuit will pull down to operating temperature in less than 1 hour in most conditions. Electrical The power cord is a 15 amp cord that requires 115 VAC, 60Hz, and 1 phase electricity. Refer to the wiring diagram included in this manual for a detailed schematic. WARNING: Always disconnect power cord before servicing. DUMP TANK CO2 CYLINDER ACCESS DOOR REMOVABLE DUMP TANK DRAIN TUBE FROM DRAINER CABINET ACCESS HOLE CHAIN FOR SECURING CO2 CYLINDER CO2 TANK (Must Be Secured When Moving Cabinet) 3

Installation and Tapping Tapping a Single Valve Keg (Sankey) Be sure beer faucet is in closed position. Align keg lugs with lug openings on bottom of coupler. Turn clockwise 1 4 turn. Pull handle out and down. Keg is now tapped. Open shut-off valve on CO2 distributor located inside of the cabinet. Important: Be sure to close this valve when untapping keg. CAUTION: Do not use keg coupler as a handle to lift keg. Single Valve Keg Coupler Step 2 Step 1 Step 3 OUT DOWN Priming the Beer System Plug in top refrigeration deck, (15-amp plug), and allow condensing unit to cycle at least once, (circulation pump will run continuously), before tapping the keg. Couple beer keg to system. Beer temperature in keg should not exceed 42 F. Apply 14-17 PSIG carbon dioxide gas. Open faucet and pour for approximately 15 seconds. Close faucet and wait for at least 15 minutes to allow beer system to pack. You are now ready to tap beer. 1/4 TURN 4

PERLICK Installation and Tapping Connecting the Regulator to the CO2 Cylinder Remove blue plug from regulator fitting. (Note: Do not remove the carbonic washer). Screw regulator onto gas cylinder valve. Tighten with wrench until vertically straight. Be sure that shut-off valve (black lever) on regulator is in the OFF (horizontal) position. Place a screw clamp over end of red air line and push onto regulator tailpiece. Tighten clamp with a screwdriver. CO2 PRESSURE GAUGE FITTING FOR RED AIR HOSE Adjusting the CO2 Gas Flow Turn regulator adjusting screw counterclockwise until it turns freely. Turn hand valve counterclockwise on CO2 cylinder to the fully open position. Turn regulator adjusting screw clockwise until desired pressure is reached (approximately 12-15 lbs.). The desired pressure may vary based on location/elevation. Tighten stop nut on adjusting screw. Open shut-off valve on bottom of regulator. CO2 Leak Test 10 50 SHUT-OFF VALVE (BLACK LEVER IN CLOSED POSITION) 0 30 20 40 PSI 60 REGULATOR ADJUSTING SCREW VALVE CO2 GAS DRUM Dilute a small amount of liquid dish washing soap and rub the soapy mixture around each connection. If bubbles appear, tighten connection. Replacing CO2 Gas Cylinder Turn CO2 hand valve clockwise until seated and close shut-off valve on regulator. Unscrew regulator from cylinder fitting. Replace carbonic washer (Part No. 157F2P), if needed and reattach regulator to filled cylinder. Turn CO2 hand valve counterclockwise until fully open. Turn regulator shut-off valve to open position. Adjust CO2 gas flow as required, turning clock wise for higher pressure. Proper CO2 Handling always... Connect a regulator (reducing valve) to CO2 cylinder. Secure cylinder in upright position whether in storage or in use. Keep cylinder away from heat. Rupture disc vents at 122 F. maximum. Ventilate room after high pressure gas leakage. Check the last DOT test date on cylinder neck before filling. If more than five years old, the cylinder must be retested to DOT specifications. Be sure CO2 cylinder outlet fitting is free of dust or dirt before attaching regulator. Store CO2 cylinder and regulator assembly upright. Allow only properly trained and experienced personnel to handle high pressure gas. never... Connect cylinder directly to a keg without a regulator (reducing valve). Drop or throw regulator or CO2 cylinder. Transport CO2 cylinder in a closed vehicle. Apply oil to a regulator. Shut off CO2 cylinder when not in use. You will not save gas by doing so! Allow untrained, inexperienced personnel to handle high pressure gas. Failure to heed this warning could result in personal injury or death. 5

Cleaning the Beer System The entire beer system, to include the faucet, flexible beer line and tapping devices must be cleaned at regular intervals. We recommend flushing the entire system with fresh water immediately after a keg has been emptied. Every two weeks or before each use the system should be cleaned chemically. It is recommended that you purchase Perlick s Pump Type Cleaning Kit. It is equipped with an adapter that attaches directly to the faucet shank, jar with pump, cleaning solution, faucet brush and spanner wrench. Cleaning the draft beer system will help to eliminate the buildup of the following materials: Bacteria: Beer is an excellent food for bacteria (none of which is harmful). Proper conditions may begin the growth of bacteria in draft beer and on the beer faucet. By regular cleaning, we prevent this bacterial buildup and maintain the quality of the draft beer. Greenish or yellowish colored material on the faucet may indicate bacterial growth. Yeast: All domestic draft beers contain a small amount of yeast which remains in the beer from the fermentation process. When the temperature of draft beer exceeds 50 a process of secondary fermentation may take place. The beer faucet may exhibit a white colored substance (yeast build up) if not cleaned on a regular basis. Beer Stone: All beer contains calcium which is present from the grains used in the brewing process. It is an important natural material in draft systems in that as it oxidizes it coats the internal parts of the beer lines and equipment. The beer stone will continue to build if the system is not cleaned properly or regularly and can cause drawing problems if it begins to flake off. Beer stone is present if one can see a brownish color on the faucet or inner wall of the beer line, or tobacco- like flakes in the beer. Cleaning the Cabinet Use a mild detergent and water to clean the inside and outside of the cabinet. Dry thoroughly. Never use a scouring pad or abrasive cleanser. Note: An industrial strength, commercial cleaner can be used to clean the outside of painted cabinets. 6

Pouring a Perfect Glass of Beer Step 1 Start with a clean glass. Place the glass at a 45 angle, one inch below faucet. Do not let the glass touch the faucet. Open the faucet all the way. Step 2 After the glass has reached half full, gradually bring the glass to the upright position Step 3 Let the remaining beer run straight down the middle of the glass. This ensures proper release of CO2 by producing a 3 4 to 1 foam head. Step 4 Close the faucet quickly and completely. 7

Wiring Diagrams 8

Glycol Loop Diagrams PUMP REFRIG. DECK GLYCOL TANK TUBE IN TUBE TUBE IN TUBE CABINET HEAT EXCHANGER EVAPORATOR FIN COIL FLASH CHILL/FIN COIL CIRCUIT 9

Preventative Maintenance ArcticCold Draft Dispenser Cleaning the Condenser The condensing coil should be inspected before each operation and cleaned if necessary. The condensing coil can be accessed by removing the louvered cover located on the customer side of the cabinet. The coil can be adequately cleaned with a vacuum, stiff bristled brush, or forced air. Please use care to ensure that the fins of the condenser are not bent or damaged. Glycol Level The glycol system should be checked before each operation to ensure an adequate level. The glycol reservoir can be accessed by removing the louvered cover on the refrigeration deck. The reservoir is located at the right rear of the deck, (see figure A). Remove the sponge insulation and unscrew the cover. While using a mirror, ensure the glycol level is at the visible seam inside the reservoir located approximately 2" below the threads. Contact the Perlick Corporation for proper glycol solution if needed. Pump Motors Sleeve-bearing pump motors should be oiled at least once per year, (see figure A). Casters The casters should be greased at least once every 6 months. This may be required more often if the unit is used in dusty environments. There is a grease fitting located on each caster. 26 1/2 92 3/4 91 24 3/4 43 1/16 53 3/8 10

11

8300 West Good Hope Road Milwaukee, WI 53223 Phone 414-353-7060 Fax 414-353-7069 Toll Free 800-558-5592 E-Mail: Perlick@Perlick.com www.perlick.com 12