ESRB and ESRN Installation & Safety Instructions

Similar documents
SERVICE BY QUALIFIED PERSONNEL ONLY

GTD20A Installation Instructions BRANCH CIRCUIT TRANSFER SWITCH/LIGHTING CONTROL DEVICE

I-320 SERIES AC EMERGENCY LIGHTING EQUIPMENT

Installation Instructions

MODEL RLY-DIM-D INSTALLATION INSTRUCTIONS

ILB-CP TBTS A MOUNTING DESIGN EMERGENCY LIGHTING EQUIPMENT FOR LED

Bdl60u Fluorescent Emergency Ballast

ILB-CP TBTS B MOUNTING DESIGN EMERGENCY LIGHTING EQUIPMENT FOR LED Patented. See iotaengineering.com/patents for more details

ILB-CP TBTS A MOUNTING DESIGN EMERGENCY LIGHTING EQUIPMENT FOR LED

INSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following:

MODEL LUT-ATS-D (EPC-D-F-ATS) INSTALLATION ! IMPORTANT SAFEGUARDS!

BACKUP BATTERY INSTALLATION INSTRUCTIONS

CDL8 LED Architectural

INSTALLATION INSTRUCTIONS - POWER SENTRY CONTROL POWER SENTRY CONTROL UNIT PSBCEB2 INSTALLATION INSTRUCTIONS

MODEL EPC-D-F-ATS INSTALLATION INSTRUCTIONS ! IMPORTANT SAFEGUARDS!

TSLED STAIRWELL INSTALLATION INSTRUCTIONS

MaxLite LED Round Pendant Highbay Series

1 Description. 2 Specifications. HP600ULM Access Control Power Supply/Charger with Power Distribution Controller PN 52393:A 1/05/06 ECN

Installation Instructions

LUCE 1 TL. specifications: internal. specifications: external. ordering logic. builder. Job/Location:

Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.

SECTION LOW VOLTAGE LIGHTING CONTROLS

A. This Section includes the following lighting control devices:

LED Emergency Battery Backup

Firefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL

DRC12FR DRC12FR347. Dynalite. Install Guide

INSTALLATION INSTRUCTIONS - PS1055LCP & PS1555LCP LED EMERGENCY DRIVER PS1055LCP & PS1555LCP

LED Emergency Battery Backup Installation Instructions Ordering Code: EB23UQ

Douglas Lighting Controls. Bluetooth Fixture Controller & Sensor. Installation Manual BT-FMS-A. *Patent Pending. Installation Guide BT-FMS-A v7

Relay Panel and Relay Panel Module Wiring and installation manual Light is OSRAM

SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL

SECTION LIGHTING CONTROL DEVICES

AUTO RESET ALARM RELEASE BOX MODEL AR-C INSTRUCTION MANUAL

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

Cold Deck Canopy and Shelf Lights and Retrofit Kit

Operating Instructions. For. Alarm Control Module. Model SSR 500

A. This Section includes the following lighting control devices:

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL

IN2 Lighting Control Devices

600 Watt Dimmer Install Guide

Cold Deck FIT. Canopy and Shelf Lights and Retrofit Kit. Installation Guide for General Information. Tools and Accessories Recommended

TS0 Series Portable Bulb and Capillary

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option

Ultrasonic Wall Switch Occupancy Sensor Single Circuit

Freeze Protection Thermostat TRACON MODEL GPT 3 Installation and Operation Manual

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

Dual Input ph/orp Analyzer

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

MODEL B2 INSTALLATION MANUAL

MaxLite LED Vapor Tight Linear Fixture

THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL

Honeywell Durafit LED Retrofit Kit

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

Power Supply Display Module PSDM. Installation and Operation Manual

THE "SS90" SERIES RELEASE DEVICES MODEL B2 INSTALLATION MANUAL

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

Tri-Stack Smart System

Innovative Lighting R-Series Overhead LED Conversion Kits

DHL-LP-LED Low Profile LED Linear High/Low Bay

Installation Instructions. PS902 Power Supply. These instructions cover the following parts: PS902 Power Supply Specifi cations:

UC700 EMERGENCY TRANSFER SYSTEM SPECIFIER S HANDBOOK. 40 Dale Street West Babylon, NY Ph: Fx:

LIGHTING CONTROL DEVICES

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

Albeo TM LED Luminaire Accessory (Emergency Battery Backup Module)

SECTION LIGHTING CONTROLS

HighLINER 2. General Information: FOR YOUR SAFETY. Installation Guide for C1I75, L1C1I75, C2I75, L135C2I75

Passive Infrared (PIR) Wall Switch Occupancy Sensor Dual Circuit

Dual Input ph/conductivity Analyzer

1 General Description

SECTION 26 NX DISTRIBUTED INTELLIGENCE LIGHTING CONTROL SYSTEM HUBBELL CONTROL SOLUTIONS

GCW SERIES Gas Cylinder Warmers

MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL

F series. Complete Room Controller. echoflex Powered by ETC. Product Overview ERDRC-FC

WARNING. Installation Tip: Try out this unit before installing onto a fire door system. Test and learn the release INTRODUCTION

SERIES VAC Microprocessor-Based Hot Surface Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION AGENCY CERTIFICATIONS

MADE IN THE U.S.A. ADVANCE FIRE CONTROL MODEL LM21-AFC MANUAL RELEASE DEVICES TEST WEEKLY TO ASSURE PROPER OPERATION OF RELEASE DEVICE/CONTROL PANEL

MaxLite LED VAPOR TIGHT LINEAR FIXTURES

S5JB Quick Setup Guide. Refer to the instructions on the following pages for complete details on the steps outlined below.

Installation Instructions

Multilift Vertical Platform Lift OWNER S MANUAL

Innovative Lighting R-Series Vertical Refrigeration

Innovative Lighting R-Series Horizontal Case Canopy LED Conversion Kits

INSTALLATION INSTRUCTIONS

20W and 45W Dimmable LED Power Supply INSTALLATION GUIDE. Copyright ASP Holdings, Inc.

Application Note. Using XPoint Wireless Devices with Emergency Lighting. 1 of 16

Installation Instructions for W2H Series Signals

Dual Technology Wall Switch Occupancy Sensor. Manual & Specification

Cold Door 2 LED Retrofit Kit Lighting System

Emergency Lighting Transfer System Model: ELTS2 Installation and User Operation Manual

SERIES VAC Microprocessor-Based Direct Spark Ignition Control with Inducer Blower Relay FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

for combining TwO gas furnaces for PARAllel OPeRATIONs using The Rccl-cOIl (heating ANd AIR conditioning)

SERIES VAC Microprocessor-Based Direct Spark Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION. Export Information (USA)

YP7999A1000 ControLinks Fuel Air Ratio Control Panel

MODELS SafeSite LED Linear, Class I Div. 1 2 & 4 Versions

MODEL GPT-130 SINGLE POINT HEAT TRACE CONTROL THERMOSTAT

SAVE THESE INSTRUCTIONS INSTALLATION INSTRUCTIONS EMERGENCY FLUORESCENT BATTERY PACK MODEL PS300, PS600, PS1400

INSTRUCTION MANUAL. AlarmGard Chain Operator (Model FCA) AlarmGard Crank Operator (Model FKA)

OPERATION MANUAL. CLASSIC 10 and CLASSIC 18 SERIAL NUMBER FROM JANUARY 2009 (0109) TO PRESENT

CRESTRON: GREEN LIGHT NETWORK LIGHTING CONTROLS 1

Transcription:

B1784 ESRB and ESRN Installation & Safety Instructions IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following: READ AND FOLLOW ALL SAFETY INSTRUCTIONS ALL SERVICING SHOULD BE PERFORMED BY QUALIFIED PERSONNEL This product is intended for use with lighting fixtures controlled by an panel. Any switching between Backup Power and Power must be done upstream of this device. All wiring connections and mounting styles must be in accordance with the National Electical Code (NEC), National Fire Protection Association (NFPA), National Electrical Safety Code, state and local codes, and any other regulations set forth by the local Authority Having Jurisdiction (AHJ). Per NFPA 70E, the use of Personal Protective Equipment (PPE) may be required. Check state and local codes. The load s operating voltage must be the same as the Power Input voltage. To reduce the risk of electrical shock, fire, and injury to persons: 1. Disconnect all sources of power before servicing, 2. Mount this device in locations and at heights where it will not be readily accessible to tampering by unauthorized personnel, 3. Do not mount near gas or electric heaters, 4. Do not let any wires touch hot surfaces, and 5. Do not use outdoors (NEMA 1 rating only) The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition. Do not use this device for other than intended use. SAVE THESE INSTRUCTIONS 1

Specifications Electrical Specifications (ESRB, ESRN) Power Supply Voltage Power Current Draw Power Operating Frequency Power Supply Voltage Power Current Draw Power Operating Frequency 120-277Vac 24mA max 50/60Hz 120-277Vac 118mA max 50/60Hz Remote Test Input (Class 2, Dry Contact) ESRTB or other switching method ¹, ² Feedback/Dimmer Contact Switching Capability (Dry Contact Output) Relay Contact (ESRN) SPST Relay Contact (ESRB) SPST 130mA @ 250V max 20A Magnetic Ballast @ 277V 16A Electronic Ballast @ 277V 10A Tungsten @ 120V 10A Magnetic Ballast @ 277V 10A Electronic Ballast @ 277V 10A Tungsten @ 120V 1: If not using the ESRTB Remote Test Button (sold separately), switching methods should be rated for at least 24Vdc. External voltage should not be supplied to this input. No specific current rating is required. 2: To maintain Class 2, a maximum of 45 total test inputs (ESRB and/or ESRN) can be wired in parallel per ESRTB. Mechanical Specifications Housing: Wire: Weight: Operating Temperature: Humidity Range: Approvals: UL accepted for use in Plenum, NEMA 1 16 600V Rated 0.675 lbs. (ESRN) 0.40 lbs (ESRB) -30 to 140 F (-35 to 60 C) 5 to 95% (noncondensing) Rated for dry and damp locations only UL listed, UL924, C-UL, 2

Installation ALL INSTALLATIONS AND WIRING SHOULD BE DONE BY QUALIFIED PERSONNEL ESRB Steps 1. Remove all sources of power. 2. Remove ballast channel cover. 3. Mount ESRB as shown in Figures A and B. 4. Wire the ESRB using an illustration from the Typical Applications section on page 4 or similar setups for different application. 5. Before applying power, review the Important Safeguards at the beginning of this document. 6. Finish installation as required by the NEC, NFPA, state, local, and other codes. Test the ESRB using the Test Procedure on page 6. Ballast Ballast Channel Cover Figure A Figure B ESRN Steps 1. Remove all sources of power. 2. Remove wiring compartment cover. 3. Mount ESRN (a couple of mounting options are shown in Figures C and D ). 4. Wire the ESRN using an illustration from the Typical Applications section on page 4 or similar setups for different application. 5. Install the wiring compartment cover. 6. Apply all sources of power to the fixture. 7. Test the ESRN using the Test Procedure on page 6. Operation Figure C The ESRB and the ESRN will activate an lighting load automatically upon the loss of Power. If Power is absent, the status of the load cannot be overridden. However, if the Power is present, the lighting load can be controlled by other means in order to use it as a Lighting load, depending on the wiring setup. When used as Lighting, a two second delay will keep the Load on, even after Wall Switch is turned off, to perform a Self-Test on the unit. When Power is present, a status contact will automatically close. Therefore, when Power is absent, the status contact will open (perfect for 0-10V dimming controls). A red LED indicates the Power is available. A Green LED indicates that Power is present. A Yellow LED copies the status of the load; if the LED is on, the load is on. Figure D Load Maintenance No routine maintenance is required for the ESRB or ESRN. Occasionally, this device should be tested to ensure that it works correctly in accordance with national and local codes. 3

Typical Applications Using Lighting as Lighting Automatic Transfer Switch Breaker Brown R ESR Y Blue / Lighting Breaker Wall Switch Yellow * White/Black Black G Control Circuitry Violet or Terminal 1 Violet or Terminal 2 White/Red or Terminal 3 Power Feedback Status (Dry Contact Output) Red White/Blue or Terminal 4 ^ * The White/Black wire must be on the same branch circuit as the Black wire. To use Remote Test Input, the White/Black wire must be de-energized. Input can also be sent to a controller. Lighting ^ Class 2 Remote Test Input (N/O) for button, controller, or fire alarm panel Remote Test Button (Model ESRTB) sold separately When not using the Remote Test Input, cap off the White/ Red and White/Blue wires individually (if present). Overriding a 0-10Vdc Dimmer Automatic Transfer Switch Brown Yellow R ESR Control Circuitry Y Blue Violet or Terminal 1 Violet or Terminal 2 / Lighting Black G White/Red or Terminal 3 Red White/Blue or Terminal 4 ^ * The White/Black wire must be on the same branch circuit as the Black wire. To use Remote Test Input, the White/Black wire must be de-energized. Input can also be sent to a controller. * White/Black Lighting ^ Class 2 Remote Test Input (N/O) for button, controller, or fire alarm panel Remote Test Button (Model ESRTB) sold separately When not using the Remote Test Input, cap off the White/ Red and White/Blue wires individually (if present). H N + - 0-10V Dimmer Control 4

Wiring Descriptions Wire Color Description Notes BLACK WHITE/BLACK RED BROWN BLUE Wall Switch Input (Self-Test Input) or other Phase Switched to load YELLOW or other Phase N/A WHITE/BLUE (ESRB) Terminal Screw 4 (ESRN) WHITE/RED (ESRB) Terminal Screw 3 (ESRN) VIOLETS (ESRB) Terminal Screws 1,2 (ESRN) Remote Test Input (Class 2, Dry Contact Input) Feedback/Dimmer Contact (Dry Contact Output) N/A Must be from same branch circuit as Black and Red. When switched off, a two second delay keeps the load on to test Power. Does not test Feedback/ Dimmer Output. N/A N/A Switches out the voltage put in on Brown When wiring multiple units together, White/Blue or Terminal Screw 4 must be a shared common. Test is performed when Input is CLOSED. OPEN when Power is Absent or Remote Test Input is CLOSED. CLOSED when Power is Present or Remote Test Input is OPEN. Wall Switch Input does not test this output. 5

Testing and Troubleshooting Test Procedure: Four options to test the ESRB and ESRN after installation: Initial Test for Correct Wiring Apply Power to the Power Input and Power to the Power Input. (If using the Wall Switch Input, apply Power to the switch also, but keep the switch OFF/OPEN.) a. The Red LED ( Power available) should be ON. b. The Green LED ( Power available) should be ON. c. The Yellow LED (Load Status) should be OFF. d. The Load should be OFF. e. The Feedback/Dimmer Contact should be CLOSED. Local Test Button 1. Turn switched circuit OFF. light should be OFF. 2. Press and hold Local Test Button 3. light should turn ON. 4. Release Local Test Button and emergency light should turn off. Remote Test Button (Model ESRTB - sold separately) 1. Turn switched circuit OFF. light should be OFF. 2. Press and hold Remote Test Button 3. light should turn ON. 4. Release Remote Test Button and emergency light should turn off. Wall Switch 1. Turn ON wall switch if not already on. 2. light should turn ON. 3. Turn wall switch OFF. 4. light will remain on for two seconds before turning off. To test the ESRB and ESRN periodically, repeat the appropriate Test Procedure above in accordance with national and local codes. Troubleshooting Condition Action Red LED is OFF Check Power Input wiring (Brown and Yellow wires) and voltage. Green LED is OFF Yellow LED is ON but Load is OFF Load is ON but Yellow LED is OFF Yellow LED and Load do not turn on when being tested. Yellow LED and Load will not turn OFF Check Power Input wiring (Black and Red wires) and voltage. Check bulbs and ballast. Check Load wiring (Blue wire and Load s neutral). Verify Load s operating voltage is the same as the Power Input Voltage. Replace unit. Replace unit. Check bulbs and ballast. Check wiring connections if using a remote test option. Press local test button on the unit. Replace unit. Verify status of Power Input. Open Wall Switch Input. Verify that no test inputs are stuck closed. (i.e. Remote Test Input is not closed). 6