Cooler Manual XRC-3012-WA 3000 Watt water to air cooler

Similar documents
WL User Manual. Innovative Technology for a Connected World. global solutions: local support TM

Coolers / Chillers. Accessories for oil cooled units. Overview. Accessories for water cooled units. Industrial X-Ray

Cool IR. Model C104 - Cooling System. Instruction Manual

PROJECT MANUAL GUIDE SPECIFICATIONS FOR: PFANNENBERG SERIES CC COMPACT PACKAGED CHILLERS PART 1 GENERAL

P/N CC-100. Coolant Circulator. Operation manual

8008 CIRCULATION UNIT FOR SOLAR THERMAL SYSTEMS, FLOW AND RETURN.

INSTALLATION AND OPERATING INSTRUCTIONS General operating instructions for sample gas conditioner Model: MAK 6

Rev B, 9/2/2009. Kodiak Chiller Overview

Modern Auto Tech Study Guide Chapters 39 & 40 Pages Cooling Systems 43 Points. Automotive Service

TECHNICAL NOTICE GH/GHO/GAE V

INSTRUCTION MANUAL HETO CBN 8 / 18 / C Cooling Baths ID: IM.doc Revision 1

REMOTE COOLER AIR COOLED & WATER COOLED

Condensate FreeFlo. Condensate FreeFlo. Homeowner Guide. Installation Guide. Indicator Light. Running Costs. Product Overview

Chapter 39 Cooling System Fundamentals Test

Illustration shows item no Z Original operating manual. Operating manual. BlueMobil eco. Item no: Z-3278

A few simple steps to ensure perfect water, every time.

GLYCOL CHILLER INSTRUCTIONS IMPORTANT: BEFORE OPERATING PLEASE SEE INSTRUCTIONS ON PAGE 9

6. COOLING SYSTEM 6-0 COOLING SYSTEM MXU 500

COOLARC 46 OPERATOR S MANUAL IM /2016 REV03 ENGLISH

Installation, operation and care Wall-mounted electric boiler MP THL nr. - rev 02

Portable Ice Maker User Guide

VC-1, VC-1-SL, VC-2-L, VC-2-SL

CIRCO 6 Solar Circulation Unit

Manual OW Caution:

Engine Block Heater Service Kits (Tank Type) ROZJ 6076T and 6076A (John Deere Powered Standby Generator Sets)

KK70 Silent. Installation and Operating Instructions L V001

Product Data Sheet Refrigeration Dryer DFLO 66 (-W) bis DFLO 2400 (-W)

GLYCOL CHILLER INSTRUCTIONS IMPORTANT: BEFORE OPERATING PLEASE SEE INSTRUCTIONS ON PAGE 5

Operating instructions

Polar Air Dryer. Instructions Manual PDRCF PDRCF R E F R I G E R A T E D T Y P E C O M P R E S S E D A I R D R Y E R S

Instruction manual ROTACOOL

(PD[ $LU 'U\HU 5 ( ) 5, * ( 5 $ 7 ( ' 7 < 3 ( & ( 6 6 ( ' $, 5 ' 5 < ( 5 6 ('5&) ದ ('5&) Instructions Manual

Operation Manual. Water-Water Cooler WW Version 1.0

A few simple steps to ensure perfect water, every time.

Recirculating Chiller RC350G-RC400G RC1400G-RC3000G. Operating Manual

WATER PUMP REQUESTED INFORMATION STANDARD PROCEDURE RAM Pickup 6.7L Eng 2500 STANDARD PROCEDURE - COOLANT AIR EVACUATION

REFRIGERATED RECIRCULATORY COOLER

THERMAL SYSTEMS, INC. Installation and Operation Manual

Installation, Operation and Maintenance Manual

SECTION 1D ENGINE COOLING

OPERATION and MAINTENANCE INSTRUCTION MANUAL. ADU-12 Task Force Pneumatic Portable Dental System

Installation, operating and servicing instructions

Installing the Turbo Floor Model System

NON-SUBMERSIBLE WATER PUMP

COOLARC-50C OPERATOR S MANUAL. IM /2011 Rev. 00

User manual. - A brand of EuroCave Group -

AIRTERM DIRT AND AIRTERM MAG COMBINED SELF-CLEANING DIRT SEPARATORS / DEAERATORS

FHHT 18 3 PHASE /32A / 400V ELECTRIC HEATER PRODUCT MANUAL P

Warning: 230V / 1ph / 50Hz V / 3ph / 50Hz. Remarks: Make sure that you have enough power. (See page 15 Cable table)

Bedienungsanleitung. Ideas for dental technology. Made in Germany C

Illustration shows item no Z Original operating manual. Operating manual. BlueMobil 60. Item no: Z-3285

A few simple steps to ensure perfect water, every time.

COOLING SYSTEM. Page CO-2 TROUBLESHOOTING... CO-4 CHECK AND REPLACEMEANT OF ENGINE COOLANT... WATER PUMP... DESCRIPTION...

Operating Instructions

02 COOLING SYSTEM 02 COOLING SYSTEM COOLING SYSTEM INDEX. 1. General Specifications... 65

USER-MANUAL Tamson Cool Cube Immersion Cooler

Rothera Container 82. DSF Clean Lab. British Antarctic Survey. Royal Netherlands Institute for Sea Research. In partnership with

OPERATING INSTRUCTIONS. for. Liquid Recooling System. Compact Units 03/04

Commissioning a Solar Thermal Installation

AUTOMATIC ICE-CUBE MAKER - INSTRUCTIONS AND WARNINGS

AIR COMPRESSOR TC UTC TC UTC125502

SATK50-60 series CONTENTS. Recess Mounted Heat Interface Unit - SATK series INSTRUCTIONS FOR INSTALLATION, COMMISSIONING AND MAINTENANCE

ACT-HSC Series Heat Sink Coolers Sealed Enclosure Cooling Installation Guide

MW001 Integrated Dishwasher. Manual for Installation, Use and Maintenance

RECORD SUBMITTAL COVER SHEET

Atlas Copco Oil-injected Rotary Screw Compressors GA 15-22/GA /GA VSD (11-30 kw/15-40 hp)

Heating and Cooling Systems

RecoverX-CAR Contaminated Automotive Refrigerant Recovery System Operation and Maintenance Manual

INSTALLATION, OPERATION AND MAINTENANCE MANUAL FOR MODEL RH REMOTE HORIZONTAL AIR COOLED HEAT EXCHANGERS

OXYVD8WCOUS OXYVG8WCOUS OXY2TVD6COUS. User manual. - A brand of EuroCave Group -

OPERATING INSTRUCTIONS. for the heat press. Secabo TPD7 PREMIUM

Engine Block Heater Service Kits (Tank Type) 30RZ/33RZ/45RZ (CSG 649 Ford Powered) Standby Generator Sets

Dear Valued Customer:

FWC860 Wine Cooler Installation, Use and Maintenance

TTV 4500 / TTV 4500 HP / TTV 7000

OEM Alpha Thermostat direct Analog

General System Layout Sketch

LK Electric Boiler - 4,5

OIL-INJECTED ROTARY SCREW COMPRESSORS. GA 5-11 (5,5-11 kw/7,5-15 hp)

OIL-INJECTED ROTARY SCREW COMPRESSORS. GA 7-75 VSD+ (7-75 kw/ hp)

6. Cooling System XCITING 400i. This chapter covers the location and servicing of the cooling system components for the KYMCO XCITING 400i.

OIL-INJECTED ROTARY SCREW COMPRESSORS. GA 7-37 VSD+ (7-37 kw/10-50 hp)

PolyMax H2-24 Dutch Bucket System

Installation and User's Manual for Residential Ice Machine. Models SCCG30 and SCCP30

OIL-INJECTED ROTARY SCREW COMPRESSORS. GA 5-11 (5,5-11 kw/7,5-15 hp)

Sedan Range. Remove and destroy Bulletin 14-13, amended 10/97. Replace with this Bulletin. Revised text is marked with a bar and in bold text.

1 of 8 5/11/17, 10:01 AM

HEATFAST HF9101-V1 AMBIENT SENSING TRACE HEATING THERMOSTAT

OWNER S MANUAL. Vintage Signature Series models: AC750, AC1050, AC1100, AC1250, AC1500, AC1750. Proudly Made in the USA.

A few simple steps to ensure perfect water, every time.

PRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h

Industrial X-Ray. Cooler Manual XRC-4523-OA 4500 Watt Oil to Air Cooler

P550W Series Air Dryers

EVAPORATIVE COOLER PUMPS

CUMULUS CUMULUS. Key figures. Construction. Function Integrated chilled beams

HEATING AND VENTILATION

MAIN FEATURES ADVANTAGES BENEFITS BOSS TRANSFORMER COMBI HF 110 CHEMICAL AND PHYSICAL FEATURES PACKAGING FEATURES

SAFETY AND OPERATING MANUAL

READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

DURANGO 12V Heater HF

Transcription:

Industrial X-Ray Cooler Manual XRC-3012-WA 3000 Watt water to air cooler XRC-3012-WA, Doc.-No. 50005645 Page 1 of 13

Document history Version Date Author Amendment(s) Status 12/15/2008 St. Haferl released 1.0 07/22/2010 M. Schmid Layout / Structure 07/22/2010 St. Haferl released 3.0 05/18/2011 M. Schmid Technical Details 4.0 10/30/2012 R. Moser Storage temperature 5.0 07/01/2013 R. Moser Update Chapter 3 6.0 01/12/2015 M. Schmid New electrical drawing XRC-3012-WA, Doc.-No. 50005645 Page 2 of 13

Contents Industrial X-Ray 1 Before you start 4 2 Product Description 5 3 Technical data 6 3.1 Physical dimensions 6 3.2 Performance data 6 3.3 Environmental specifications 6 3.4 Settings 6 3.5 Performance data and overview 7 4 Installation 8 4.1 Antifreeze concentration 8 5 Maintenance 9 6 Outline Drawing 10 7 Circuit Diagrams 11 7.1 Electrical diagram 11 7.2 Block diagram 12 8 Declaration of conformity 13 XRC-3012-WA, Doc.-No. 50005645 Page 3 of 13

1 Before you start Read the manual before setting into operation! Coolant: Water or water-glycol mixture (max. 1:1 water - glycol) Power supply 230 V 50/60 Hz! Run cooling unit always with correct coolant level otherwise cooling capacity is reduced! Clean filter regularly according to maintenance instructions, otherwise damage of pump may occur! Never operate cooling unit when ball cock is closed, otherwise damage of pump may occur! Only use cooling hoses with sufficient pressure resistance and with resistance to used coolant! Never operate damaged or leaking equipment! Before starting any service work disconnect the cooling unit from the mains. XRC-3012-WA, Doc.-No. 50005645 Page 4 of 13

2 Product Description The cooling unit XRC-3012-WA is designed for the cooling of a water circuit. The coolant can be water or a mixture of water and antifreeze (water-glycol). Water circulates between the cooling unit and the heat source. The water is re-cooled by an aircooled heat exchanger. The system pressure is limited by a bypass valve. Cooling hoses are connected to the cooling unit via Walther couplings. Coolant inlet and outlet are marked with the labels: Inlet: O ; Outlet: O The water flow is monitored by an adjustable flow switch, the water temperature by a thermal switch. The contacts of the flow switch and the thermal switch are available as potential free signals on the internal terminal block: safety circuit. Both contacts are connected in series as one common error signal on the external Cannon connector. The contact is open when: The water flow is below the minimal set value The temperature of the coolant is higher than the maximal set value XRC-3012-WA, Doc.-No. 50005645 Page 5 of 13

3 Technical data 3.1 Physical dimensions Length: Width: Height: Weight: Coolant capacity: 483 mm 406 mm 481 mm 38.5 kg without filling 4.0 l 3.2 Performance data Cooling capacity: 3000 W ( T 11 K) Flow rate: 5.4 l / min at 4 bar Mains voltage: 230 V + 10% - 15% 48-62 Hz Current consumption: 2.6 A Noise level: 55 db(a) (50 Hz) distance 1m in any direction 59 db(a) (60 Hz) distance 1 m in any direction Airflow at 50Hz (60Hz): 2200 m 3 /h (2600 m 3 /h) Safety class: IP 33 3.3 Environmental specifications Operational temperature: -10 C...+ 40 C (use antifreeze if ambient temperature is below 10 C) Storage temperature: -25 C...+ 70 C (store with antifreeze) Air humidity: 20%...90% non condensing 3.4 Settings Maximum forward pressure: 6.7 bar Flow switch open: < 4.0 l/min Flow switch close: > 4.2 l/min Thermal switch open: > 50 C Thermal switch close: < 45 C This setting value is optimized for our XRS modules XRC-3012-WA, Doc.-No. 50005645 Page 6 of 13

3.5 Performance data and overview Temperature difference forward - ambient Cooling capacity (in Watt) Filler Cap Electrical Connection Water Inlet Water Outlet Water Drain Overview XRC-3012-WA, Doc.-No. 50005645 Page 7 of 13

4 Installation The cooling unit must be positioned upright with sufficient clearance for air circulation (minimum clearance of 0,5m from the ventilation grid) Connect the hoses on the cooling unit, respect the flow direction The maximum hose length is 20m provided that the cooler and the heat source are on the same level. If there is a height difference between both, it is shorter. If the unit is exposed to ambient temperature below 0 C, prepare about 4.0 l of water mixed to Glycol according to the concentration table below Open the lid and fill the cooling unit with the cooling mixture (about 4.0 l) Notice: The liquid level must be always above the fins, otherwise the cooling capacity will be reduced! Switch on the unit (main switch on the control unit of the X-ray generator). Let the cooling unit run for about 10 minutes to deaerate the water circuit then check the level and refill if required. Close the lid Connect the electrical cable to the X-ray generator, at the rear of the power unit 4.1 Antifreeze concentration It is essential that the correct antifreeze mix is added. The recommended antifreeze product is Ethylenglycol. See the table below for your guidance. Consult your antifreeze supplier for Ethylenglycol. Concentration by volume (%) Approximate freezing point (ºC) 20-9 25-12 30-15 50-25 XRC-3012-WA, Doc.-No. 50005645 Page 8 of 13

5 Maintenance Regularly check the water level and refill if necessary. Heat exchanger In order to achieve the maximum cooling capacity, keep the heat exchanger of the cooling unit clean. Regularly check it and if necessary clean it: Proceed as following: Disconnect cooling unit from the mains Remove complete cover Remove dust by forcing it out in the opposite direction from which it entered. If compressed air is available, direct the air against the inside of the heat exchanger Mount cover Pump About every 6 months check the filter of the pump for clean condition, if necessary more often. For this proceed as following: Note: If the filter is not in clean condition damage of pump and motor may occur! Proceed as following: Disconnect cooling unit from the mains Remove cover Close ball cock Unscrew filter cap (24 mm nut) Note:Some water will run out of pump. Collect the water with suitable vessel! Clean filter if necessary or replace filter Insert filter and mount cap Open ball cock Attention: Never operate cooling unit when ball cock is closed, otherwise damage of pump may occur! Mount cover Run cooling unit to deaerate cooling circuit (see Setting to work) Check water level and refill if necessary Placing out of operation/service/repair Disconnect cooling unit from the mains Remove hoses Remove cap and drain of coolant, collect with suitable vessel Mount cap XRC-3012-WA, Doc.-No. 50005645 Page 9 of 13

6 Outline Drawing XRC-3012-WA, Doc.-No. 50005645 Page 10 of 13

7 Circuit Diagrams 7.1 Electrical diagram Attention: The cooler has to be fused when used as a stand alone unit with 4A, slow blow type. The default plug is a Cannon plug. XRC-3012-WA, Doc.-No. 50005645 Page 11 of 13

7.2 Block diagram XRC-3012-WA, Doc.-No. 50005645 Page 12 of 13

8 Declaration of conformity XRC-3012-WA, Doc.-No. 50005645 Page 13 of 13