WLM3 the 3 rd generation of the OJ Waterline TM Control Systems. Industry leading intelligence, control SLIDE OJ Electronics

Similar documents
OJ Waterline control system

intelligent controls for hydronic floor heating

Product Catalogue. energyefficient hydronic. floor heating and cooling in one FLOOR HEATING HYDRONIC HVAC CONTROLS & POWER FLOOR HEATING ELECTRIC

Enhance the performance of every system

WLM2 WLTA WLTD WLTP WLCT2

GIACOMINI UNDERFLOOR HEATING CONTROLS GUIDE

WLM2 Networking. WLM2 Networking O J W A T E R L I N E

Underfloor Catalogue Heating products that define the market

Roth Touchline. German quality since Quick and easy user manual 1/10

30 radiators from one central point. Simply smarter heating. living.danfoss.com. living by Danfoss heating control

NEW. Innovative heating controls. Commercial boiler control systems. Control 8000 & MX25

Installation & Operating Instructions

ECL Comfort 300 / V a.c. and 24 V a.c.

User start guide Connected wireless room thermostat Logic Combi C / Vogue Gen 2 Combi Logic Max Combi C / Vogue Max Combi Vogue Combi C / Logic Combi

ECL Comfort 310 controller, Remote Control Units ECA 30 / 31 and Application keys

evohome multi-zone system evohome

Vaillant vsmart. Sales Presentation. Search vsmart for the App, which includes a demo!

ProCon 16, 31, 47 & 75. RVA 63 Boiler and Circuit Controller Commissioning Data.

Model: Touch-RF. 1 Wireless Series

Fingertip control, optimum efficiency, total comfort and clear reporting. warmafloor.co.uk

HEAT TROL ELITE SERIES HWE-Single Stage, HWE-MOV, HWE-Mulit Stage Hot Water Reset Control for Light Commercial and Residential Applications Provides q

Description of the. controllers. Description of the. system extension possibilities. RS communication. Front panel made of glass. Control of 2 valves

2-way. One source of elements. Many opportunities for greater profits. communication

120+ Get your job done swiftly Easy selection of your application is the key. applications.

Roth Touchline. German quality since User manual quick and easy guide 1/10

ECL Comfort 210 controller, Remote Control Units ECA 30 / 31 and Application keys Designed in Denmark

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems

P20. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort P20. User's Guide. Installer's Guide *VI7BD502* *087R8014* *087R8014* *VI7BD502*

ECL Comfort 110, application 116

Operating Instructions Model: PRT-TS WiFi RF. 01/13 Version 1 Ref: PRT-TSWIFI RF

Operating Guide. ECL Comfort 210 / 296 / 310, application A247 / A Table of Contents

ECL Comfort V a.c. and 24 V a.c.

Galaxy Pulsar Plus Digital Battery Plant Controller

SYX660 Commissioning Guide V Page 1 of 55

ECL Comfort 210 controller, Remote Control Units ECA 30 / 31 and Application keys

ECL Comfort 110, application 130

Weather compensated flow temperature control of heating and boiler systems

Heating is great when you control it. USER MANUAL. Wireless Programmable Room Thermostat. Model No.: LS Scan for App

C37. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort C37. User's Guide. Installer's Guide *VI7CE602* *087R8070* *087R8070* *VI7CE602*

Installation Guide. ECL Comfort 310, application A Table of Contents

Ventilation in balance

Priceguide August 2013

CLIMAV 2.0 Thermoregulation Systems

4iE Smart WiFi Thermostat Operating Guide

Manual for the integration in BMS/GTC

Table of Contents. Product Image 1 Locking/Unlocking the neoair 24 Table of Contents 2 Frost Protection 25 What is a Programmable Room Thermostat?

Stylish Thermostats For Modern Living

One Product Numerous Applications Electronic Controllers for Heating, Cooling, Ventilation and Air Condition

Overview - Danfoss Link and living software versions

prestige Control Application Supplement - TriMax

Intelligent heating controller for your home

RACK MONITORING SYSTEM - RAMOS Ultra

Manual & Technical Documentation V1.1

Corrigo E. Second generation which contains all applications and languages

C62. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort C62. User's Guide. Installer's Guide *VIKME102* *087R8091* *087R8091* *VIKME102*

Measuring Recording Online Monitoring Regulation Alarming

Home. evohome WiFi MULTI-ZONE SYSTEM

evohome controls evohome consists of a number of quality components manufactured by the UK s leading manufacturer of home heating controls.

SAUTER EY-modulo 5. The complete building management solution.

Healthy. Atmosphere. for Pigs and Poultry. for a

Installation Guide. ECL Comfort 210, application A Table of Contents

Electronic controllers. Comfort embellishes everyday life

Hydronic & HVAC Control Systems

PRODUCT CATALOG INSTALLATION CONTROLLERS ROOM REGULATORS ZONE HEATING CONTROL FLOOR HEATING CONTROL BOILER CONTROLLERS SOLAR SYSTEMS CONTROLLERS

ECL Comfort V a.c. and 24 V a.c.

C66. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort C66. User's Guide. Installer's Guide. *vi7cc502* *087R8069* *087R8069* *vi7cc502*

Thermostats & smart controls. neohub+ UNDERFLOOR HEATING HEAT PUMPS SOLAR THERMAL

Heat Link. Technical Guide

Wired Solutions Wired Heating Control Products

Underfloor Heating and Cooling Controls RELIABLE, ENERGY EFFICIENT CONTROLS FEATURING UNIQUE

DAP III Zone Master User s Guide

SEQUENCE OF OPERATIONS

ECL Comfort V a.c. and 24 V a.c.

Specification Data. General:

Why Vaillant? Because there s smart and then there s vsmart. Vaillant vsmart. The USER Guide

SYX66x Commissioning Guide V Page 1 of 61

Dew point. Special features: Dew point monitoring DS 400. Technical data DS 400. Technical data FA 510

5.5. Other configuration parameters EXCEPTION CODES AUTO DIAGNOSTICS Zoning box control board

Modulating clock thermostat

Overview - Danfoss Link and living software versions

Heating Control Danfoss Link & Connect Thermostats

Home. evohome multi-zone, Lyric T6 programmable thermostat and Single Zone thermostat. Smart Heating Controls THE COMPLETE CONNECTED CHOICE

The ECL Comfort 110 is a universal 1-circuit controller for use in district heating substations and district heating systems as well as boilerbased

ECL Comfort 210 / 296 / 310

TPOne-B. Electronic Programmable Room Thermostat. Installation Guide. Danfoss Heating

Sun Ray Electric Radiators Stylish, Efficient, Low Energy

ProCon 16, 31, 47, 75, 77 & HT. RVA 46. Zone Controller Commissioning Data.

CONDAIR EL. Electrode boiler steam humidifier Easy maintenance with replaceable cylinders. Humidification and Evaporative Cooling

Nu-Heat. options. warm water underfloor heating. design innovation expertise service U N D E R F L O O R

Gardening the smart way. GARDENA smart system. gardena.com

Installation Manual. Zoning Kit

USER GUIDE Wireless room thermostat with hot water control (DHW & single zone CH)

prestige Control Application Supplement - ACVMax

TECHNOLOGY TECHNOLOGY

Optimize your HVAC/R application with the right Danfoss components

CS-11 LCD Timeswitch: Central Time Control of Multiple Thermostats

Added password for IP setup page : Password must be in IP format!

G a

Maglink consoles Site manager & top level software Filling stations and fuel depots management MAGNETOSTRICTIVE & WIRELESS TECHNOLOGY

4 in 1 Digital Thermostat Control

Transcription:

WLM3 the 3 rd generation of the OJ Waterline TM Control Systems Industry leading intelligence, control and operation SLIDE 1

Designed to deliver value for all. Benefits; Reliability - Fit and Forget Flexibility One system solution for any size application Homeowners Cost-savings savings - Reducing system issues Comfortable and intuitive control Supports the integrity of your business Personalised installations Maximised sales - Backward compatible with WLM2 Management of your environment. (Back-light will not be operable) Cost-savings by energy reduction. Installers Easy installation Minimise Call-backs. Suitable for all installation type domestic or commercial Promote a reliable solution SLIDE 2

The OJ Waterline TM Control System consist of two main parts; Masters Ensure optimum operation of boilers, pumps and water temperature Controllers/Sensors Ensure easy installation, high comfort, energy and cost efficiency with a high level l of flexibility SLIDE 3

These can be powered with wired, wireless or mixed connectivity Wired connection Up to 300 metres with up to 100 metres between any two unit Wireless connection Can be established by simple connecting a receiver can be added to existing wired system. Safe voltage The 2-wire system is based on a 5 Volt low voltage communication bus, and is perfectly safe for end users under all conditions SLIDE 4

OJ Waterline TM WLM3 Controllers/Sensors SLIDE 5

OJ Waterline TM WLM3 Master Product Range WLM3-xFS Digital master WLM3-xBA Standard master Universal masters For wired and wireless systems 8 actuator outputs Pump & Boiler control AO module Extensions of outputs t 6 actuator outputs Connection of room sensors/controllers Wired and wireless room sensors & controllers can be connected to the same master WLM3-xAO Add-on module Wireless function Connection of one or more external receivers Exercise function To optimize lifetime of valves and pumps, these will be exercised every 72 hours during inactive periods SLIDE 6

OJ Waterline TM WLM3 Master Features Master with eight outputs For thermal a actuators Add On module with additional six outputs Networking of Masters: Adds support for large installations. i Double output terminals for thermal actuators: Ensures easy connection of more loops to the same channel output Easy interconnections:rj14 connectors like telephone plugs - for quick connection of Add On module and Receiver to enable wireless operation Output for motorized 0-10VDC mixing valve: Enables control of supply water temperature SLIDE 7

OJ Waterline TM WLM3 Master Features Supports Radiator zones, Domestic Hot Water heating and two step heating: floor + boost unit like radiator Room sensors and controllers are designed for easy wall mounting and battery replacement Temperature on time Early start: Adaptive function ensures the desired temperature on time Advanced Cooling features: Dew point protection through optional humidity sensors prevents condensing on floors Control of connected dehumidifier, possibility for cooling and heating on different outputs Communication interface for Building Management Systems (BMS) and Gateway for remote smartphone access. SLIDE 8

OJ Waterline TM WLM3 Master Specification/Defaults Product Outputs Supply voltage Standard Master 8 230 V Digital Master 8 230 V AO-module 6 230 V Actuator output 230V WLM3-1BA WLM3-1FS WLM3-1AO Actuator output 24V WLM3-3BA WLM3-3FS WLM3-3AO Control of mixing valve No Yes, delivery incl. sensor Weather compensation No Yes, with optional Outdoor module type WLOC3-19 Temperature settings Fixed Factory settings Default settings User settings Comfort temperature 21ºC 21ºC +5/+40ºC Setback temperature 18ºC 18ºC +5/+40ºC Min. limitation 17ºC 17ºC +10/+30ºC Max. limitation it ti 27ºC 27ºC +10/+40ºC Frost protection 5ºC 5ºC +3/+8ºC SLIDE 9

OJ Waterline TM room sensor/controller product range WLTP3 non-adjustable version WLTA3 Standard Room Sensor WLTM3 & WLTD3 Room Sensor with setting mode WLDT3 Room Sensor with Display WLCT3 Room Controller with built-in clock functions Design & mounting Control of temperature Modern design line with big 3.2 inch PI-control for accurate & stable comfort backlit display Individual room temperature adjustment Surface wall mounting or to standard ±4 C compared to system set point. socket Wireless or Hard wired versions Emergency frost protection on flat batteries or loss of communication. Floor limit sensor for min. or max. limitation Automatic or manual setback temperature and frost protection. SLIDE 10

Room Sensors Sensors & Functions Setting Mode Switch Setting of Room Temperature Max. setting ± 4 C preventing excessive adjustment Automatic operation according to a Room Controller or the timer input on the Master. Fixed comfort temperature (21 C). Fixed setback temperature (18 C). Fixed operation temperature (frost protection of 5 C). SLIDE 11

WLCT3 Room Controller with built-in clock function Features Big 3.2 inch backlit display Automatic ti comfort and setback temperature t Adaptive function (optimum start) For control of room temperature and additional areas Pre-programmed 4 event timing, requires only actual time and day to be set. Programs can be changed. Floor limit sensor can be connected Example Night Time to sleep Wake The day begins Home Back from day activities Out Time to leave SLIDE 12

WLCT3 - Domestic Hot Water Control It is possible to control the domestic hot water temperature with a function in the clock thermostat to ensure optimum energy saving. A sensor from the thermostat measures the temperature in the storage cylinder. A zone valve is then controlled via the WLM master, which in turn activates the boiler on demand. The underfloor heating gpump pwill NOT be activated Boiler Hot Water cylinder Function in WLCT3 to enable control of the Hot Water Temperature 2-Wired type WLCT3-19 Wireless type WLCT3-29 Automatic day and night temperature. Pre-programmed, requires only actual day and time to be set. Programs can be changed. External Sensor (ETF1899a OR ETF522 must be connected. SLIDE 13 WLM- BA/FS Hot Water Sensor

WLCT3 - Radiator Control It is possible to control a radiator circuit room temperature with a special function in the Room Controller to ensure optimum energy saving. The thermostat measures the temperature in the room, and a 2 port spring return zone valve is then controlled via the WLM master, which in turn activates the boiler on demand. Boiler Radiator Special function in the WLCT3 to enable control of a Radiator zone 2-Wired type WLCT3-19 Wireless type WLCT3-29 Automatic comfort and setback temperature. Pre- programmed, requires only actual day and time to be set. Programs can be changed. WLM- BA/FS SLIDE 14

WLCT3-2 Stage Heating Control If there is a need for enabling a secondary heat source in a room (e.g. a back-up electrical radiator*), it is possible to use a special function in the Room Controller that will control two separate outputs. Additional heat source in the room Special function in the WLCT3 controller to enable control of a 2 step zone The second output will be activated only if the temperature cannot be achieved within a preset time period and a programmed hysteresis Automatic comfort and setback temperature. Pre- programmed, requires only actual day and time to be set. Programs can be changed. *PLEASE NOTE connection of the secondary heater must be in accordance with the electrical limits it of the WLM control or via a suitable relay or contactor. Boiler WLM- BA/FS Stage 2 Stage 1 Room with additional heat source SLIDE 15

Room Controller with built-in clock function Setting up areas with the room controller 1. Enter the Menu AREA in the WLCT3 Room Controller AREA 2. Choose the channels (rooms) that should get the set point from this Room Controller, by setting the channel number to On CH 1 On Channel 1 (Room 1) CH 2 Off Channel 2 (Room 2) CH14 ESC SLIDE 16

WLM3 - BMS/Remote Connection OJ Waterline TM Master Control System offers a standard MODBUS interface for Building Management Systems (BMS) The OJ Floor Managing System (FMS TM ) provides a total user interface for flexible local and remote monitoring and control SLIDE 17

BMS functions on FS masters The BMS function: In buildings with a Building Management System, this system can communicate with Example 1: the WLM3 system by using the versions Building Management Computer with BMS interface. This enables full communicating remote control to ensure optimal control with a standalone and energy efficiency in the building. WLM3 with BMS interface Main BMS features: Read & set all individual room & floor limit temperatures Example 2: Read all masters in a WLM3 network through the WLM3 network master. Read out status of all outputs like pumps, boiler and actuators Read & set weather compensation values Override functions to support testing Based on RS485 RTU MODBUS Read out status of all outputs like interface Example 2: Building Management Computer communicating with a network of WLM3 with BMS SLIDE 18

The OJ Waterline BMS and FMS System offers Centralised access for maintenance of building controls Masters that can be easily set, limited and activated for individual rooms and floors System balance ensuring multiple systems work together Status read-outs Override functions to support testing Communication with all masters in an OJ Waterline network through a single connection point - the OJ Waterline FS network master SLIDE 19

Intelligent temperature control for maximum comfort General features Local and remote monitoring and control MODBUS interface PC Computer type Desktop Laptop PC Computer type Tablet computer Smartphone Floor Management WLM2 FS/B Device Heating and FMS FMS Online (Internet) cooling controller FMS Mobile ios/android/blackberry Samsung/Windows phone/nokia Connection types Ethernet, web or Lan connectivity Bluetooth FMS Web Windows/Linus/iOS System requirements (underfloor heating controls) WLM3-xFS master WLM3-xFS or WLM2-xBA (networked) WLM3 Room Sensors & Controllers FMS Desktop Windows SLIDE 20

FMS TM CRESTRON General features Interface for the WLM3-xFS Desktop, laptop, tablet or smartphone access Suitable for standard homes or commercial buildings WLM2 xfs CRESTRON Floor Management Device FMS Mobile ios/android/blackberry Samsung/Windows phone/nokia Heating and cooling controller FMS FMS Online (Internet) FMS Web Windows/Linus/iOS FMS Desktop Windows Tablet Device SLIDE 21

FMS TM SIP General features Management user interface for the OJ Electronics WLM3- Waterline Master System Built in ModBus for Plug & Play installation WLM2 FS/B Trend BMS Floor Management Gateway Controlled from any PC or laptop computer via an IP connection o Ethernet, web or LAN connectivity Heating and cooling controller FMS FMS Online (Internet) FMS Web Remote monitoring / control of BMS system FMS Desktop Windows Building Management Front End System Trend 963 SLIDE 22

WLM3 Product Features SLIDE 23

Network Functions In large buildings with multiple areas it is possible to use a master to create a network of multiple zones. Circulation pump control of each string A network master could be a Digital Master for centralized control of mixed supply water or a Basic Master where no mixing is required. Slave Masters can then be added to the network to create additional zones. Slave Masters controlling a common pump are connected as a string on the network system. Boiler String 2 WLM- WLM- WLM- BA/FS 2,1 BA/FS 2,2 BA/FS 2,3 WLM-AO String 1 WLM- BA/FS 1,1 WLM- BA/FS 1,2 Network communication cable WLM-BA/ FS 1,3 Up to 15 strings, each of up to 9 masters, can be connected as a network. WLM- BA/FS 0,0 WLAC interface ID-selectors on the Masters Have to be set in order to Identify the master on the network SLIDE 24

Cooling functions In addition to controlling heating, all WLM masters have the ability to control the system for cooling. String 1 A WLAC3 module is required for the master to know that cooling is required. WLM- BA/FS 2,1 WLM- BA/FS 2,2 WLM- BA/FS 2,3 By using a WLHX3-19 humidity sensor the system handles DEW-point problems. Humidity sensors is attached to each master, and in a network the worst case situation will control the water supply temperature. If cooling is being limited due to high humidity a dehumidifier can be enabled by a master. Energy source WLM- BA/FS 0,0 Local attached humidity sensor for local dew point protection Changeover module WLAC3-19 for switching between heating and cooling When cooling is enabled the cooling set point will be pre-determined by the master and will override any settings in any clock thermostat to ensure optimum energy efficiency. Signal for cooling/heating changeover SLIDE 25

OJ Waterline TM Room Sensors/Controllers incl. Floor Sensor The Air Sensor For control of room temperature Min. temperature limitation Gives a minimum surface temperature of the floor, even when the air temperature is above the set point. Recommended for tiled floors to ensure high comfort. The Floor limit Sensor with priority is for limitation of floor temperature. Max. temperature limitation Prevents too high temperatures damaging the floor material. Recommended as protection to wood floors. SLIDE 26

Control of Room Temperature Traditional ON/OFF control Over and undershoots the room temperature meaning poor comfort and energy waste as an end user tends to increase the set point while feeling cold at the undershoot periods Advanced PI-control No over and undershooting of temperature ensures high and stable temperature comfort with a minimum energy consumption 20.5 C OFF 20.0 C 19.5 C HEAT 100% ON SLIDE 27

Adaptive Function (Optimum Start) Adaptive function (optimum start) The adaptive function allows the start time of the heating system to be automatically varied Provides energy savings, but ensures that the room will reach the correct temperature at the desired time A Room Controller is necessary on the system for the adaptive function to operate All Rooms controlled by a Room Controller can use the adaptive function Temperature Comfort mode Adaptive area Winter Summer Setback mode time SLIDE 28