Decentralised Mechanical Extract Ventilation 2 Speed Axial Extract Fan with Humidity Enabler Installation Guide

Similar documents
Decentralised Mechanical Extract Ventilation 2 Speed Axial Extract Fan Installation Guide. Fig. 2 Fan components.

230V/24V DC SELV Surface and Semi-Recessed Mounted Domestic Fans INSTALLATION AND MAINTENANCE. n Wall mounting kit

MEV-DC. Continuous Mechanical Extract Ventilation Units Installation and Maintenance. Figure 3. Fixing screw hole.

Installation and Maintenance

FAITH (dmev) 230V / 24V DC SELV Flush Mounted Domestic Continuous Extract Fans

isense & isense-ht 230V Flush Mounted Domestic Continuous Extract Fans

Intake air from outside. Supply air to house. Extract air. from house. Extract air from house. Exhaust air from house to outside

FLAT2000L/R. Low Energy Positive Input Ventilation Unit. Installation and Maintenance. Alternative inlet position. 2.1 Spigot Inserts.

Installation and Maintenance. Opus OK / Genie NKF1 Kitchen Extract Unit. Contents IMPORTANT WARNING IMPORTANT! Introduction WARNING!

MRXBOX95-WALL. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Extract air.

XB-EFA-8L-BK & XB-EFA-8R-BK

MRXBOX95B-LOFT. Mechanical Ventilation Unit with Heat Recovery & Summer Bypass for Loft Mounting. Installation and Maintenance

ES-LCD User Control SD Card Location

Installation and Maintenance

Installation and Maintenance

MEV Ecosmart. Installation and Maintenance. Continuous Mechanical Extract Ventilation Units. 1.0 Introduction

Installation and Maintenance

Installation and Maintenance

Installation and Maintenance

ECOSMART XTRACTOR. (ESX-X/R/B) 1 phase, Direct Drive For External, Roof Mounted and Internal use Installation and Maintenance.

Installation and Maintenance

MRXBOX95-LH1/LH2. Mechanical Ventilation Unit with Heat Recovery for Loft Mounting Installation and Maintenance. Spigot 4.

DRI-ECO-HEAT-HCS Whole House Ventilation Unit with Hall Control

INDOOR USE ONLY. Installation and Maintenance XTRACTOR. (ESX) 1 and 3 phase, Direct Drive, Fans for indoor use

DRI-365 Anti-Condensation and Whole House Positive Input Ventilation Unit

ECOSMART TWINFANS. (EST) 1 phase, Direct Drive, Run & Standby Fans for indoor use. Installation and Maintenance

Natural Ventilation. e-stack A-Series Ventilation System for Buildings with Atria. Installation and Maintenance. Palletised

Installation and Maintenance. OPUS 30 and 60. Duct Mounted ('M' range) Domestic Extract Fans IMPORTANT WARNING

MRXBOX95-WH1. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Intake air from outside

DRI-ECO-LINK-HC 1.0 INTRODUCTION 4.0 DIFFUSER INSTALLATION 2.0 IMPORTANT NOTES TO INSTALLERS 3.0 LOFT INSPECTION

AP-EH500-L/RQA9837. Installation Guide

ECOSMART TWINFANS. (EST-X/R/B) 1 phase, Direct Drive, Run & Standby For External, Roof Mounted and Internal use Installation and Maintenance

MRXBOX95-WH1. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Bracket

NTD-125-*, NTD-204-* & NTD-220-* Nuaire Round & Rectangular Thermal Ducting Installation Guide

WHHR Midi & Midi Lite

MRXBOX95-WM2H. Mechanical Ventilation Unit with Heat Recovery and Integral Humidistat for Wall Mounting Installation and Maintenance

MRXBOX95-WM2. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Intake air from outside

Centrif Duo & Centrif Duo Plus

airooncentre.co.uk irconcentre.co.uk Xpelair Low Energy Wall/Window Fan Range GX6 EC2 GXC6 EC2 Quick Order Hotline or

ELIX 1003 IPX4. Energy Efficient Centrifugal Fan with EC Motor Installation and Operating Instructions

MODEL: DV72 R & L. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual

MRXBOX95AB-WH1. Mechanical Ventilation Unit with Heat Recovery & Summer Bypass for Wall Mounting. Installation and Maintenance

Ecosmart Boxer. AHU s (Fan Speed Control only) Installation and Maintenance. LPHW Heater

IF IN DOUBT, INSTALLATION SHOULD BE MADE BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH CURRENT WIRING REGULATIONS.

Lo-Carbon Quadra Centrifugal Fan

Application and Installation Guide (excluding Solar Air Collectors)

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS.

IMPROVING INDOOR AIR QUALITY IN NEW HOMES. MECHANICAL EXTRACT VENTILATION (MEV & dmev)

"WHHR125DC" Whole House Heat Recovery Unit with Low Energy DC Motor. Installation, Operating and Maintenance Instructions domestic and commercial use

Intake air from outside. Supply air to house. Extract air. from house. Extract air from house. Exhaust air from house to outside

Internal/External Wall/Window Fan Range GX6. Installation and maintenance instructions Retain for future use

Lo-Carbon Quadra SELV

DRI-ECO-HEAT-HC. Whole House Ventilation Unit with Hall Control. Installation, Maintenance and Operation

ELEGANCE IPX4 IPX7. Low Carbon Fan with EC Motor Installation and Operating Instructions. 6 models:

"Microbox" DC Models MBOX 125/2DC MBOX 125/2DC204

Lo-Carbon SELV Tempra

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

QUALITY SPACE HEATERS

Thank you for choosing EnviroVent

Lo-Carbon SOLO Plus SELV Centrifugal Bathroom/Toilet Fan

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

Warnings, Safety Information and Guidance

Lo-Carbon MULTIVENT MVDC-MS & MVDC-MS H VENTILATION SYSTEMS V~50Hz. Installation and Wiring Instructions IP22. Stock Ref.

Thank you for choosing EnviroVent

Titon HRV1 Q Plus HRV1.5 Q Plus HRV2 Q Plus Heat Recovery Ventilation Units

T-SERIES. Window & Roof Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz

HR200WK Through the wall Heat Recovery Ventilator

Purge Ventilation Unit. Product Manual. ventilation systems TP625

ECo 2 Wall INSTALLATION GUIDE FOR ENGINEER / INSTALLER

Xpelair Simply Silent TM Contour Fan

Simply Silent Contour 4 (100mm) Axial Extraction Fan

Model: Kair Whole House Ventilator Model Number: KHRVWH2000

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

MRXBOX95AB-WH2 (with automatic summer bypass)

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

Xpelair Simply Silent DX150

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit

Lo-Carbon Quadra Centrifugal Fan

Installation, Operating and Servicing Instructions

LV100 Standard LV100PC Pull Cord LV100T Timer LV100H Humidistat LV100HP Humidistat and Pull Cord LV100PIR

Unity CV2GIP Decentralised Mechanical Extract Ventilation (dmev) Installation Instructions

Titon CME1 Q Plus Mechanical Extract Ventilation Unit

DRIMASTER 2000 and DRI S Anti-Condensation & Whole House Ventilation Unit Installation and Maintenance

Integra. Integra Plus EC MVHR. Installation & Commissioning. Stock Ref. N EC Integra Plus EC PLEASE RETAIN THESE INSTRUCTIONS WITH THE PRODUCT.

T-SERIES. Wall & Panel Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz

irconcentre.co.uk airooncentre.co.uk

Cooker Hood CHIM60 CHIM70 CHIM90 CHIM101 CHIM110. Installation & User s instructions

Installation & Operating Instructions

VA 150 A, VA 150 P WINDOW EXTRACT FAN. Installation and Wiring Instructions V/1/50Hz

MRXBOX90S. Mechanical Ventilation with Heat Recovery. Installation and Maintenance

Xpelair Simply Silent DX100B

nergybulbs.co.uk Domestic AC Fans 230V Installation and Operating Guide Quick Order Hotline or

energisava 200 CEILING MOUNTED VERSION INSTALLATION GUIDE FOR ENGINEER / INSTALLER

Technical data. Bathroom/shower room installations. Water services (WRAS approved)

MEV SPIDER INSTALLATION GUIDE FOR ENGINEER / INSTALLER

Lo-Carbon T-series Window & Roof Models

CREATING A HEALTHY INDOOR ENVIRONMENT POSITIVE INPUT VENTILATION (PIV)

Centair CMEV.4 / CMEV.4e / CMEV.4eHT Mechanical Extract Ventilation (MEV) System Installation Instructions

Installation and Maintenance Instructions for the Installer. Please refer to the User Manual for instructions on how to operate the system

INTEGRA PLUS ABC. 230V~ 50Hz. Stock Ref. N. Installation and Wiring Instructions IPX2

Transcription:

.0 Introduction The dmevh is a speed axial extract fan has been designed for continuous ventilation for kitchens or wet rooms and should be installed using 00mm dia. ducting. Speed settings are fixed at either ow Speed and ow Boost or High Speed and High Boost (See Section 9.0 for Details). As a default, the fan is set to achieve low speed (4 l/s wet rooms) to adjust to high speed (6 l/s - kitchen) refer to section 9.0..0 Handling Always handle the the fan carefully to avoid damage and distortion. 4.0 Spacer installation (if required) dmevh Decentralised Mechanical Extract Ventilation Speed Axial Extract Fan with Humidity Enabler Installation Guide The EMC Directive 04/0/EU The ow Voltage Directive 04/5/EU.0 Installation The installation must be carried out by competent personnel in accordance with the appropriate authority and conforming to all statutory and governing regulations i.e. IEE, CIBSE, HVCA etc. The unit is for indoor use only, and is suitable for through wall and ceiling installation. Mount on a secure, vibration free surface away from any direct source of heat and areas where it would be subjected to water spray. The maximum permissible ambient temperature is 50 o C. dmevh Box Contents Fan unit (Including part inlet grille and fixing screws), wiring grommets ( off), a cable clamp c/w screws and spacer. Figure. Wire outlet position DMEVH & DMEV+H OY Snap off top lug (highlighted in grey) (eight lugs in total, two in each corner) Corner post once top lugs have been removed Fig. Spacer Installation Having established the mounting position for the unit, mark the centres of duct hole and four fixing points using the template provided on page 5. Core cut the centre duct hole, drill and plug mounting holes. When using surface mounted cabling select the most appropriate cable entry position and carefully trim out the inner and outer cable cut-outs. Secure spacer to the wall / ceiling (fixings supplied by others). ote: use wood screws not countersink screws to avoid distorting the skirt. Chased in Cable: Feed the cable through the spacer to pass through back plate for when installing fan. uaire: A Trading Division of Polypipe imited Western Industrial Estate Caerphilly United Kingdom CF8 A T: 09 088 59 F: 09 088 70 E: info@nuaire.co.uk W: www.nuaire.co.uk

Installation and Maintenance Decentralised Mechanical Extract Ventilation Speed Axial Extract Fan 5.0 Wall / Ceiling Installation a) Placing the Fan Unit. Having established the mounting position for your fan, you need to cut a suitable size hole through the Wall or Ceiling to accommodate the 00mm dia. Spigot on the fan unit. Place the fan unit into the hole and mark up 4 fixing points (4 corners of fan unit rear section, shown in fig a). Drill marked up holes and add suitable fixing plugs (Supplied by others). Figure a. b) Prepare wiring for the fan. Wiring can be fed through either the back or the right hand side of the fan unit rear section. Motor Cap. c) Fitting the Fan Unit. Insert 00mm dia. ducting (Pre-cut the duct length to suit the wall/ceiling that duct is going through) through the hole previously cut, then insert the fan unit into the duct and secure using suitable fixings (Supplied by others). Ensure that the wiring is fed through the fan unit rear section at the chosen exit point. Figure b. d) Wiring the Fan Unit. Please revert to section 7.0 for full wiring diagram. Ensure supply cable is clamped inside the unit (Clamp and Screws supplied). e) Setting the Humidity Trigger set point. Please revert to section 0.0 for Set point options. f) Finishing the Install. Once the unit has been wired and humidity trigger set point has been selected the front facia of the fan unit can be fitted. Once cover and rear section are slotted together, fit the fixing screws (supplied) to the bottom face, fig. b. Fixing Screws.

75 46 0 90 Installation and Maintenance Decentralised Mechanical Extract Ventilation Speed Axial Extract Fan 6.0 Dimensions Figure. dmevh fan unit. Figure 4. dmevh fan and room grille. 0 4 98.5 40 Figure 5. dmevh fan unit rear section. 5 96 Figure 6. dmevh fan and room grille side section. 7.5 50.5 U 7.0 Electrical Voltage: Frequency: 8.0 Wiring Figure 7. 0V OTE: In the event of voltage transients or other EMC interference on the mains supply the fan may go into boost for seconds or possibly for the run on time period. Operation will be restored to normal after the interference stops. If severe EMC interference causes the fan to go into permanent boost the mains power should be reset to restore functionality. If high levels of RF interference causes the fan to go into boost during the period of RF interference EMC mitigation procedures may be required. Contact uaire service dept for further support. Unit serving bathroom or kitchen (optional boost) Optional remote switch Unit serving bathroom (via light switch) S S Mains 0V amp Mains 0V Fan unit / Pole isolator Fuse A Fan unit Pole isolator Fuse A

Installation and Maintenance Decentralised Mechanical Extract Ventilation Speed Axial Extract Fan 9.0 Speed Settings The dmevh is pre-set to achieve 4 l/s Continuous and 8 l/s on boost. This can however be changed to 6 l/s Continuous and l/s on boost. To change these speed setting you will need to change the jumper position within the fan unit (fig. 8). To do this you will need to remove the fixing screws on the motor cap (shown in fig. a). Figure 8. ow High Unit is fixed speed. Select between either ow or High speed with the jumper position. i.e. Bathroom installation ow speed (Pre-set factory position). S Speed ow ow High High Setting: Continuous Boost Continuous Boost Air Flow: 4 l/s 8 l/s 6 l/s l/s 0.0 Humidity Set Point The dmevh is pre-set to boost when it senses a relative humidity (%RH) of 80% however this can be changed to suit the installation. To do this you will need to access the PCB within the unit. On the PCB you will need to alter the humidity switch (fig. 9a) configuration to suit the configurations in (fig. 9b). Figure 9a. Figure 9b. 0V Switch live 0V eutral 60% RH 0V ive 70% RH Humidity sensor Humidity switch 80% RH 90% RH Switch actuator.0 Maintenance The fan unit does not require any maintenance. However, for optimum performance, it is advisable to remove any accumulated dust with a low power vacuum cleaner. ote: Installation and Maintenance of the equipment must be as directed in the instructions provided with the unit..0 Warranty The 5 year warranty starts from the day of delivery and includes parts and labour for the first year. The remaining 4 years covers replacement parts only. This warranty is void if the equipment is modified without authorisation, is incorrectly applied, misused, disassembled, or not installed, commissioned and maintained in accordance with the details contained in this manual and general good practice. The product warranty applies to the UK mainland and in accordance with Clause 4 of our Conditions of Sale. Customers purchasing from outside of the UK should contact uaire International Sales office for further details..0 After Sales For technical assistance or further product information, including spare parts and replacement components, please contact the After Sales Department. Telephone 090 858 400 Technical or commercial considerations may, from time to time, make it necessary to alter the design, performance and dimensions of equipment and the right is reserved to make such changes without prior notice. 4

Installation and Maintenance Decentralised Mechanical Extract Ventilation Speed Axial Extract Fan 4.0 Skirt Spacer Template B Wire outlet positions A ESURE THE BASE AIGS WITH THE BASE MARKIGS O THE MOUDIG BASE ote, if printing document check scale. A = 47.8mm B = 00.7mm 5