OPTISENS TUR 2000 Technical Datasheet

Similar documents
OPTIBAR DP 7060 Supplementary Instructions

SECTION Process and Immersion Turbidity and Total Suspended Solids Sensor

Turbimax CUE21 / CUE22

WIO200 Water In Oil measuring instrument

OPTIWAVE X500 Supplementary Instructions

Turbimax CUE21 / CUE22

Snifter ATEX22 VERSION. User Manual. Distributor

WIO200 Water in oil sensor

AquaLynx 200 ADX. Monitoring and Control System. Background. Operation

OPTIBAR P 1010/2010 C Supplementary instructions

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

Duct and Rough Service Carbon Monoxide Sensor

DESIGN MANUAL. The information in this doucment is applicable to sensors built in September, 2009 or later (Firmware 3.0)

LINEAR HEAT DETECTION CABLE DURÁN-SAFE

L1L2L3. 99 Washington Street Melrose, MA Phone Toll Free Visit us at

Concise catalogue Water-Industry

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

Snifter. User Manual. Distributor

Operating Manual MS220KA and MSR220KA

S304 and S305 Dust Emission Monitors. User Manual. Distributor

SAFEYE XENON 700. Hydrocarbons and ethylene detection. Heated optics. 10-year Warranty for the Xenon flash bulb. SIL 2 according to IEC 61508

Rev B, 9/2/2009. Kodiak Chiller Overview

Analyze IT Zirconia Oxygen Analyzer for Small Boiler Applications

Model Q45P/R. ph/orp Monitor...

SECTION Fluorescent Dissolved Oxygen Measuring System

URD20SE. Gas detectors Carbon dioxide (CO 2 ) ATEX certified (II 2G Ex d IIC T6) Use. Operation. Ordering

Introduction Portable Meters Transmitter Probes RELATIVE HUMIDITY

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

INSTRUCTION MANUAL & 8200 Monitor. Manual Issue 06

Inductive Conductivity

Sintrol Snifter A2 EX. Manual. Version 1.2.3

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

SET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions

SET-2000 Hi Level/Oil

Analog Room Pressure Monitor RPC Series

EKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING. Manual

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

Model 144H. Product Data Sheet , Rev DB February Content

Model Q45P/R. ph/orp Monitor...

TLS 500. Installation and Operation Manual. English Pages CEDES AG is certified according to ISO 9001: V 1.1.

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Phone: Fax:

Danfoss gas detection unit Type GD Heavy Duty

INSTRUCTION MANUAL. DECKMA HAMBURG GmbH. Type OMD-12. Oil-in-Water Monitor

CLARITY II TURBIDIMETER

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

Operating instructions

COMPACT FLAME CONTROLLER CFC 1000

LC3000 Level Controller Installation and Maintenance Instructions

TCS5JBL & TCS5JBLA. Low-Voltage Top-Up Switch

Remote alarm indicator and test combination MK2430

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

Sintrol Snifter A1+ Manual. Version 1.2.2

DESIGN MANUAL MODEL GIR900 INFRARED COMBUSTIBLE GAS SENSOR

Labkotec Ice Detector

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

TLS 600. Installation and Operation Manual. English Pages CEDES AG is certified according to ISO 9001: V 1.0.

rev3 INSTALLATION & OPERATION MANUAL OIL CIRCULATING HEATING SYSTEM MODEL OSM

! WARNING. Before using product, read and understand instructions.

INTRODUCTION / TABLE OF CONTENTS

SEC Signature Process Gas Analyzer

Danfoss gas detection units

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

ExDetector IRCO2. ExDetector IRHC. Operating and Installation Instructions. Gas Detection and Warning Systems

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

PolyGard 2-channel Gas Controller MGC-03

Process & TeMPerATUre UniversAl input DigiTAl MeTers

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

Process Alarm Module RTA 421

DL424/425 DirectLine Sensor Module for Dissolved Oxygen Probes Series DL5000 Specifications

COMPACT FLAME CONTROLLER CFC 2000

SAFETY CERTIFIED MODEL FP-700 COMBUSTIBLE GAS DETECTOR

RE-PR3-E-27 3-Phase Panel Mount 27kW

EN - english. Instructions for installation and operation. Mobile humidity meter DP 207

Micro/Ultra Filtration System StamoClean CAT 430

DMFPM-2R MULTIFUNCTIONAL

Ultrasonic Point Level Switches

Technical Information OUSTF10

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

Flameproof Manual Call Points

Rosemount 3490 Series 4 20 ma + HART Compatible Controller

QUALITY ASSURANCE/QUALITY CONTROL DOCUMENTATION SERIES OPTEC NGN-2 NEPHELOMETER AUDIT PROCEDURES (IMPROVE PROTOCOL) STANDARD OPERATING PROCEDURE

Magnetic-Inductive Flow Velocity Sensor PIT. Installation and Operating Instructions

Leakage detection sensor

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

1. Quick start-up guide

LINEAR HEAT DETECTION CABLE DURÁN-SAFE

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

Dust Alert 75. *shown with optional external keypad and display

WIO 200B and WIOI200B Water in oil sensor

OilSET-1000 (12 VDC)

CU 300. Installation and operating instructions GRUNDFOS INSTRUCTIONS

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option

ACTIVE INFRARED BARRIER

Transcription:

OPTISENS TUR 2000 Technical Datasheet Sensor for turbidity measurement in water and wastewater Rugged design for harsh applications Integrated transmitter with direct 4...20 ma output Near infrared light source and 90 measurement according ISO 7027 The documentation is only complete when used in combination with the relevant documentation for the signal converter. KROHNE

CONTENTS OPTISENS TUR 2000 1 Product features 3 1.1 Turbidity sensor for water and waste water application... 3 1.2 Design and options... 4 1.3 Measuring principle... 5 2 Technical data 6 2.1 Technical data... 6 2.2 Dimensions and weight... 7 3 Installation 8 3.1 Installation procedure... 8 3.2 Sensor use with cleaning function... 8 3.3 Sensor use without cleaning function... 9 3.4 Mounting the sensor into an assembly... 9 4 Electrical connections 10 4.1 Connecting the sensor cable to the signal converter... 10 4.2 Connecting the sensor directly to the control system... 12 4.3 Connecting the sensor to PC... 12 4.4 Connecting the power supply to the signal converter... 13 5 Order information 15 5.1 Order code... 15 2

OPTISENS TUR 2000 PRODUCT FEATURES 1 1.1 Turbidity sensor for water and waste water application Turbidity measurement is widely used in drinking water and wastewater applications. The turbidity measurement is used for filter monitoring and quality control of water in waste water plants. The turbidity sensor OPTISENS TUR 2000 from KROHNE has a standardized robust design for open channel measurement and a long lifespan. Therefore the sensor is especially designed for small and medium-sized wastewater treatment plants. The integrated spray cleaning nozzle minimize the need for manual cleaning, which means longer intervals between maintenance and calibration. Figure 1-1: OPTISENS TUR 2000 1 Process connection 2" NPT 2 Cleaning nozzle 3 Measuring windows 3

1 PRODUCT FEATURES OPTISENS TUR 2000 Highlights Precise turbidity measurement <40 FNU/NTU through the 90 scattered light method Measurement according to ISO 7027 Short response time for all applications Long-term stability due to reduced clogging by integrated spray cleaning nozzle Low cost of ownership due to an integrated transmitter Suitable for installation with telescopic rod SENSOFIT IMM 2000 Industries Waste water industry Applications Water quality control in the outlet Filter monitoring 1.2 Design and options This submersible turbidity sensor provides a 4...20 ma current loop or a RS485 output. The serial interface allows commands entered via the hyperterminal of a personal computer, the transmission of the measurement and check signal, the scale selection, the analog or digital operating mode selection, the zero and sensitivity calibration. The sensor is suitable for connection to a signal converter. The cleaning of the sensing element is performed by the injection of pressurised clean air, provided by the user. It can be easily adapted to various application requirements and can be installed directly into a basin with a telescopic rod. 4

OPTISENS TUR 2000 PRODUCT FEATURES 1 1.3 Measuring principle Turbidity is the cloudiness of a fluid caused by the presence of suspended and colloidal matter. In waterworks, a turbidity measurement is used to indicate the clarity of water. Technically, turbidity is an optical property of water based on the amount of light reflected by colloidal and suspended particles. The measuring unit for the turbidity is Nephelometric Turbidity Unit (NTU) or Formazine Nephelometric Unit (FNU). According to ISO 7027, turbidity values below 40 NTU / FNU have to be measured with the 90 scattered light method. The light source and receiver are positioned in a 90 angle to each other. The light transmitted from the source is directed in equal strength to the reference receiver and into the medium. Light is now reflected from the particles and fractions of the scattered light are received by the detector, positioned at a 90 angle. The meter now compares the light from the reference receiver and scattered light receiver and calculates the turbidity value. 5

2 TECHNICAL DATA OPTISENS TUR 2000 2.1 Technical data The following data is provided for general applications. If you require data that is more relevant to your specific application, please contact us or your local sales office. Additional information (certificates, special tools, software,...) and complete product documentation can be downloaded free of charge from the website (Downloadcenter). Measuring system Parameter Measuring principle Turbidity 90 scattered light Design Measuring principle Measuring scale Sensitivity NTU Zero NTU Nephelometric 0...4.000 NTU / FNU 0...40.00 NTU / FNU 0...400.0 NTU / FNU (default) 70...130% NTU ± 0.400 NTU all scales Sensor type Installation with MAC 100 signal converter or directly to control system via 4...20 ma Shaft diameter 60 mm / 2.36" Shaft length 166 mm / 6.5" Sensor thread 2" NPT Hose diameter 6.3...9.5 mm / 1/4...3/8" Operating conditions Temperature range -5...50 C / +23...122 F Pressure range Max. 1 bar at 25 C / 14.5 psi at 77 F Measuring range < 1% of end of measurement scale Response time t 90 < 120 seconds (small signal < 3%fs), < 40 seconds (high signal > 3%fs) Measuring cycle 2 seconds Relative humidity 0...95% non condensing Air pressure cleaning max. 3 bar / 43.51 psi Units displayed sensor NTU (= FNU) Installation conditions Ingress conditions Weight IP68 Body 420 g / 0.93 lb 10 meter cable 640 g / 1.41 lb Materials Sensor body PVC 6

OPTISENS TUR 2000 TECHNICAL DATA 2 Electrical connection Cable Voltage Analog output Load Digital output Approvals and certifications CE Electromagnetic compatibility 10 meter / 32.8 ft. 20 meter / 65.62 ft. 30 meter / 98.43 ft. 9...36 VDC 4...20 ma loop powered isolated 600 Ohm max. at 24 VDC RS485 This device fulfils the statutory requirements of the EC directive. The manufacturer certifies successful testing of the product by applying the CE mark. EMC Directive 2004/108/EC (valid until 2016/04/19) or EMC Directive 2014/30/EU (valid from 2016/04/20) EN 61326-2-3:2013 EN 55011:2009+A1:2010 2.2 Dimensions and weight e f Dimensions [mm] Dimensions [inch] a 60 2,4 b 18 0,71 c 15 0,6 d 100 3,94 e 140 5,51 f 25 0,98 7

3 INSTALLATION OPTISENS TUR 2000 3.1 Installation procedure The device is factory calibrated and the analog signals are set to the measurement range 0...400 NTU. To install the device in the correct way, follow the order and the following sections and their instructions. 1. Connect the sensor to the signal converter or directly to the control system. 2. Configure the measurement range. Verify or calibrate sensor if required. 3. Mount the sensor into the immersion assembly. (For further information refer to the manual of the assembly) 4. Install the sensor into its final measuring location. 3.2 Sensor use with cleaning function Most applications do not require the cleaning function if the sensor is installed correctly in a correct angle. When the automatic cleaning is required the device can be equipped with a cleaning hose for air cleaning. Before the device is installed into its final measuring location the following points must be observed provide hose (Ø 6.3...9.5 mm / 1/4...3/8") in suitable length prepare a connection for the cleaning hose push the hose onto the cleaning connector put the sensor cable and cleaning hose through the adequate extension pipe of the mounting assembly The pressurised air is to be provided and must be clean with a max of 3 bar. The typical cleaning time is 15 seconds and the typical cleaning fequency is 2 times/day, but this will differ from application to application. 8

OPTISENS TUR 2000 INSTALLATION 3 3.3 Sensor use without cleaning function Without a cap on the air line connector the sample might block the cleaning drilling for later use or water might flow into a closed assembly and damage the probe due to later handling. Before installation and immersion the sensor check the following order: Do not install any flexible tubing. Install a cap on the air line connector in order to avoid the cleaning drilling to be blocked for later use or water to flow through it into a closed assembly. 3.4 Mounting the sensor into an assembly All work on the electrical connections may only be carried out with the power disconnected. Do not turn the cable gland on the sensor this might cause a sensor leak and damage the electronics inside. While mounting or dismounting the sensor, the senor cable must not be fixed or trapped as this might loosen the water tight gland connection from the sensor. Recalibrate the sensor after each manual cleaning procedure. For further instructions on installation into an immersion assembly refer to the assembly manual. Use an assembly that does not fix the sensor cable or require the sensor to be screwed into the assembly. If the sensor needs to be screwed for mounting or dismounting make sure that the sensor cable is turned into the same direction. Installing procedure Insert the sensor cable through the immersion assembly. Fasten the sensor to the tip of the telescopic rod by tighteninng the 6 screws of the 2 holding plates. Connect the wires either to the control system directly (only 4...20 ma) or to the MAC 100 signal converter. For removing the sensor, repeat the steps above in reverse order. Calibrate the sensor before installing it into the assembly. 9

4 ELECTRICAL CONNECTIONS OPTISENS TUR 2000 4.1 Connecting the sensor cable to the signal converter All work on the electrical connections may only be carried out with the power disconnected. Take note of the voltage data on the nameplate! Look at the device nameplate to ensure that the device is delivered according to your order. Connect the turbidity sensor to the MAC100 for optimal configurability and process control due to following features: scale selection flexibility digital input to hold signals during cleaning process easy calibration via zero and sensitivity adjustment set minimum and maximum for alarm relays galvanic isolated 4...20 ma outputs error current R3 Figure 4-1: Sensor connection terminals on the signal converter 1 Sensor connection terminal 2 Relays 3 Terminal block A: terminals for sensors 4 Terminal block S (protective earth) Wire White Green Yellow Grey None Terminal block Pos.A J Q Y V W Wire Metal (non isolated cable) Terminal S S 10

OPTISENS TUR 2000 ELECTRICAL CONNECTIONS 4 Figure 4-2: Connecting the sensor cable The following instructions describe the connection of the sensor cable. Connecting the sensor cable to the signal converter Remove the terminal cover. Thread the sensor cable through the middle right cable gland 1. Push the wires 7 into terminal J 3, Q 4, Y5, V 6 and S 2. To remove a wire, press down the white clip 8 on the corresponding terminal and pull the wire out. 11

4 ELECTRICAL CONNECTIONS OPTISENS TUR 2000 4.2 Connecting the sensor directly to the control system Avoid cable interruptions. If necessary use adequate junction box. Keep the cable far away from power cables inside of the switch board. The device is loop powered and can be connected directly onto the control system via any junction box. Wire Green White Metal Function + current loop - current loop shield The normal operation needs just the connection of the green and white wires, which are protected against accidental inversion. The shield is not connected to the probe but it must be connected to the ground. 4.3 Connecting the sensor to PC Avoid cable interruptions. If necessary use adequate junction box. Keep the cable far away from power cables inside of the switch board. Connect the device to the converter or directly to the control system as stated in above chapters. The shield is not connected to the probe but it must be connected to the ground. Wire Shield Yellow Grey Brown Green White Function not connected A (+) RS485 B (-) RS485 not connected + current loop - current loop / COM RS485 12

OPTISENS TUR 2000 ELECTRICAL CONNECTIONS 4 4.4 Connecting the power supply to the signal converter The device must be grounded in accordance with regulations in order to protect personnel against electric shocks. Never install or operate the device in potentially explosive areas, it might cause an explosion that can result in fatal injuries! When connecting the power supply, always note the safety regulations of the current state of the art. Also note the following items to avoid fatal injuries, destruction or damage of the device or measuring errors: De-energise the cables of the power supply before you start any installation works! Always keep the housing of the device well closed if you do not perform any installation works. The function of the housing is to protect the electronic equipment from dust and moisture. Assure that there is a fuse protection for the infeed power circuit (I nom 16 A) and a disconnecting device (switch, circuit breaker) to isolate the signal converter. Check the nameplate and assure that the power supply meets the voltage and frequency of the device. You can operate the device in the range of 100...230 VAC and 8 VA with a tolerance of -15/+10% while 240 VAC +5% is included in the tolerance range (a version with a power supply of 24 VAC/DC is in preparation). A power supply outside these specifications may destroy the device! Assure that the protective earth conductor (PE) is longer than the L- and N-conductor. The manufacturer has designed all creepage distances and clearances according to VDE 0110 and IEC 664 for pollution degree 2. The power supply circuits fulfil the overvoltage category III and the output circuits fulfil the overvoltage category II. 13

4 ELECTRICAL CONNECTIONS OPTISENS TUR 2000 Before you start to connect the power supply cables, note the following drawing with the function of the terminals: 1 L1...L3 (live) 2 Neutral 3 Protective Earth (PE) Afterwards connect the power supply cables accordingly: The manufacturer strongly recommends to use a slotted screwdriver with a tip of 3.5 x 0.5 mm / 0.14 x 0.02" to push down the lever! Otherwise you could damage the lever. De-energise the power supply cables with the help of a disconnecting device (switch, circuit breaker)! Remove the cover of the power supply terminal (1) by pressing it down and pulling forwards at the same time (2 and 3), be careful and do not disrupt the retaining band (it prevents the cover from getting lost)! Use a slotted screwdriver with a tip of 3.5 x 0.5 mm / 0.14 x 0.02" to push down the lever, connect the wires to the terminals and pull up the levers again (4 and 5). Refasten the cover of the power supply terminal, close the converter housing and tighten all screws of the housing. 14

OPTISENS TUR 2000 ORDER INFORMATION 5 5.1 Order code The characters of the order code highlighted in light grey describe the standard. VGA W 4 Sensor type VGA W 4 A OPTISENS TUR 2000 Measuring range 4 0...4, 40, 400 NTU / FNU Sensor features A 1x 4...20 ma / RS 485 Process conditions 1-5...+50 C, 1 bar / +23...+122 F, 14.5 psi Enclosure type B Submersible with spray cleaning nozzle Body material 1 PVC Process connection A Submersible, 2" NPT male threat for mounting on SENSOFIT IMM 2000 telescopic rod Power supply 1 9...36 VDC loop powered Cable B Cable-TUR-W 2000 Cable features A Attached cable Cable length 3 10 m / 33 ft. 4 20 m / 65.6 ft. 5 30 m / 98.4 ft. Cable options 1 Wire end ferrule Sensor options 1 Spray cleaning nozzle Documentation 0 none 1 English 2 German 3 French 4 Spanish 15

K K K KROHNE Process instrumentation and measurement solutions KROHNE - Subject to change without notice. Flow Level Temperature Pressure Process Analysis Services Head Office KROHNE Messtechnik GmbH Ludwig-Krohne-Str. 5 47058 Duisburg (Germany) Tel.: +49 203 301 0 Fax: +49 203 301 10389 info@krohne.com The current list of all KROHNE contacts and addresses can be found at: