Several Ideas on Fire Detecting Alarm for Power Supply and Distribution System

Similar documents
A Study into the Standardization of Using Fire Detectors in Rail Vehicles for China

The Development of Automatic Fire Alarm Standards and Related Products in China

Design of Humidity Monitoring System Based on Virtual Instrument

Simulation of Full-scale Smoke Control in Atrium

2012 International Symposium on Safety Science and Technology Factor analysis of high-rise building fires reasons and fire protection measures

A Numerical study of the Fire-extinguishing Performance of Water Mist in an Opening Machinery Space

Full-scale Experiment of Longitudinal Ventilation Smoke Control System and Central Smoke Exhaust System in City Underwater Tunnel

ScienceDirect. Development progress of critical equipment in the CSNS cryogenic hydrogen system

Available online at ScienceDirect. Procedia Engineering 84 (2014 )

Hot Water Making Potential Using of a Conventional Air- Conditioner as an Air-Water Heat Pump

Available online at ScienceDirect. Procedia Engineering 135 (2016 )

Thermodynamic analysis of air cycle refrigeration system for Chinese train air conditioning

Construction of Wireless Fire Alarm System Based on ZigBee Technology

A study of Transient Performance of A Cascade Heat Pump System

Two-Pipe Fiber Bragg grating Temperature Sensor Applied in Cable Trench and Cable Pit

Ecological Landscape Planning and Design of an Urban Landscape Fringe Area: A Case Study of Yang an District of Jiande City

The study of sewage sludge thermo-drying efficiency

Study of Numerical Analysis on Smoke Exhaust Performance of Portable Smoke Exhaust Fan

Construction of An Automatic Power Switch using Infrared Motion Sensor

NFPA 85 COMPLIANCES OF BMS: A CASE STUDY OF BOILER CONTROL AT SBM OFFSHORE MALAYSIA COMPANY 1. AHMED ABOUELRISH 2 Universiti Teknologi Petronas

Heat transfer enhancement in an air process heater using semi-circular hollow baffles

NATIONAL STANDARD OF THE PEOPLE'S REPUBLIC OF CHINA. Code for Design of electrical installation For explosive and fire hazardous Atmospheres

OPERATIONAL GUIDELINE. Office of the Fire Commissioner O.G.# Revision #1 TITLE: ISSUING ORDERS Page 1 of 8

Available online at ScienceDirect. Procedia Engineering 135 (2016 )

( )

The Effect of Quantity of Salt on the Drying Characteristics of Fresh Noodles

The Development of Fire Risk Assessment Method for Heritage Building

Procedia - Social and Behavioral Sciences 195 ( 2015 ) World Conference on Technology, Innovation and Entrepreneurship

Monitoring Operator Guide. Access Control Manager Software Version

Material Factor for the Beauty of Modern Architecture Decoration in Harbin

Code for Design of Clean Room

Available online at ScienceDirect. Procedia Engineering 135 (2016 )

Available online at ScienceDirect. Procedia Engineering 121 (2015 )

Simulation of Evacuation Process in a Supermarket with Cellular Automata

Addressable Fire Alarm System Fire Alarm Training System

Simulation study of evacuation in high-rise buildings

Development of Bionic Air Cooler Used in High Temperature Coal Mine

Investigation, Analysis and Solution of Higher Noise of Heat Pump Water Heater

Available online at ScienceDirect. Energy Procedia 91 (2016 ) 35 41

Available online at ScienceDirect. Physics Procedia 67 (2015 )

INDOOR HUMAN THERMAL COMFORT OPTIMAL CONTROL WITH DESICCANT WHEEL COOLING SYSTEM

ARTICLE 25. FUEL GAS CODE

Grower Summary PO 005

AS/NZS :2008

New fire control system design for fire fighting and rescue equipment Jianguo LUO1, a, Zehao BU2, b

A Novel Online Cleaning System for Shell and Tube Oil Heat Exchanger

GASTEC QA. Approval Requirements 31-2

Simplex Panel Interface Guide

ISO INTERNATIONAL STANDARD. Road vehicles Four-pole electrical connectors with pins and twist lock Part 2: Tests and requirements

A three-pole dead-tank SF 6 circuit-breaker incorporating one interrupter per pole in single-pole enclosures with a common operating mechanism

GASTEC QA. Approval Requirements 31-1

Investigation of Separating Small Impurities and Heavy Compounds Using the Cotton Separator Equipment

Fire Situations and Prevention Measures of residential building

Please think twice about printing this matrix. You can it, along with your ballot to or

HYDROCARBONENGINEERING June June 2015

Performance Analysis of Water-Water Heat Pump System of 100 kw Scale for Cooling Agricultural Facilities

Performance-based Fire Design of Air-supported Membrane Coal Storage Shed

Available online at ScienceDirect. Procedia Engineering 89 (2014 )

Dispute over the requirement for fire door signage to hotel suites at 124 Devon Street West, New Plymouth

Global and China Glass Fiber Industry Report, Nov. 2011

4th International Conference on Sensors, Measurement and Intelligent Materials (ICSMIM 2015)

Safe Operation Manual. Honeywell IQ Force Gas Detector

Design of Multi-Sensors Cooperation Control System for Intelligent Building

The Design of MLX90621 Based Intelligent Lighting Control System Hui-jiao Wang*, Meng-meng Liu and Cong-cong Shi

Design of the Fiber-optic Fence Warning System with Distributed Video Real-Time Display Function Qiang-yi YI and Zheng-hong YU *

A Study on Smart City Development Project for Regional Innovation: Co-creation and Design Thinking Approach

UNDERSTANDING ELECTRICAL SAFETY RISKS

Development and Application of the Rail-type Inspection Robot used in Substation Rooms

Open Access Operation Modes and Energy Analysis of a New Ice-Storage Air- Conditioning System

Research on Evaluation of Fire Detection Algorithms

A preliminary analysis of the waterscape in face of the shortage of water

Available online at ScienceDirect. New Framework of Intelligent Evacuation System of Buildings

Basically, the instruction handbook shall contain the following information:

Implementation of the Construction Products Regulation (CPR) in harmonized standards - Template for Annex ZA -

LEARNING SPECIAL HAZARD DETECTION TYPES

BUSINESS PLAN CEN/TC 305 POTENTIALLY EXPLOSIVE ATMOSPHERES EXPLOSION PREVENTION AND PROTECTION EXECUTIVE SUMMARY

AOYUE. Int 852A+ pro Int 852A++ pro. SMD Rework Station INSTRUCTION MANUAL. (Centigrade / Fahrenheit switchable)

Research on fire protection methods and a case study "Futurum"

Structure Fires in Hotels and Motels

Installer Manual KNX Touchscreen Thermostat

G3 Electric Lubrication Pump For Series Progressive and Injector-based Systems

Available online at ScienceDirect. Procedia Engineering 146 (2016 )

Protecting our future! Advanced fire protection for pupils, teaching staff and physical assets

Effective Alarm Management for Dynamic and Vessel Control Systems

Fire Dynamics Simulation and Evacuation for a Large Shopping Center (Mall), Part II, Evacuation Scenarios

Research on the Monitor and Control System of Granary Temperature and Humidity Based on ARM

SAFETY CODES COUNCIL ORDER. BEFORE THE FIRE TECHNICAL COUNCIL On June 21, 2012

Lena s Garden. by Heather Clay. illustrated by Mary DePalma. HOUGHTON MIFFLIN Harcourt

Focused Evaluation of Rainwater Harvesting: A Case Study in Sandakan, Sabah, Malaysia

Australian Standard. Degrees of protection provided by enclosures (IP Code) AS IEC Ed 2.1:2001 AS 60529

Property risk solutions

SURVEY ON FIRE SERVICE INSTALLATIONS FOR OFFICE BUILDINGS IN HONG KONG

Application Note on Reading the Vigilohm IM400 Insulation Monitoring Device Installed in Conext Core XC and XC-NA Series Inverters

ABB Medium Voltage Days MEA 2016 Proactive safety ABB medium-voltage switchgear

COST-EFFECTIVE FIRE-SAFETY RETROFITS FOR CANADIAN GOVERNMENT OFFICE BUILDINGS

NATIONAL COMPETENCY STANDARD

Proceedings Design, Fabrication and Optimization of a Silicon MEMS Natural Gas Sensor

Electrical Hazards and NFPA-70E: Protecting Your Employees

***** 2. Rev.1 is to be uniformly implemented by IACS Members from 1 July 2004.

Using BIM model for Fire Emergency Evacuation Plan

Transcription:

Available online at www.sciencedirect.com Procedia Engineering 11 (2011) 75 79 The 5 th Conference on Performance-based Fire and Fire Protection Engineering Several Ideas on Fire Detecting Alarm for Power Supply and Distribution System DING Hong-jun a,b, LIU Xiao-lu a,b,* a School of Information Engineering, Wuhan University of Technology, Wuhan 430070, China b Shenyang Fire Research Institute, Ministry of Public Security, Shenyang 110031, China Abstract Through the cases of fire in the power supply and distribution system for iron and steel enterprises, the basic causes and the main fire parts for the fire in the power supply and distribution system have been analyzed. Types of fire in the power supply and distribution system are summarized. Several ideas for prevention of fire that will occur in the power supply and distribution system are put forward. 2011 Published by Elsevier Ltd. Open access under CC BY-NC-ND license. Keywords: power supply and distribution system; electrical fire; monitoring of electrical fire; leakage current; detection alarm 1. Fire case analysis Management Group of National standards Code of design on fire protection and prevention for iron & steel metallurgy enterprises GB50414-2007 counted Fire examples occurred over the past decade in iron & steel metallurgy enterprises, statistical results in table 1. Table 1.Statistics of fires * Corresponding author. Tel.: +86-24-31535976; fax: +86-24-31535979. E-mail address: liuxiaolu@syfri.cn. 1877 7058 2011 Published by Elsevier Ltd. doi:10.1016/j.proeng.2011.04.629 Open access under CC BY-NC-ND license.

76 DING Hong-jun and LIU Xiao-lu / Procedia Engineering 11 (2011) 75 79 Fire sites and fire types Times Percentage % Fire in Cable sandwich, Electrical basement, Cable tunnel, Cable shaft, etc. 27 36 Fire in Transformer, Control room, etc. 12 16 Combustible liquid fire based on High flash point oils in hydraulic station, lubricating oil station, oil storage room, oil pipeline corridor, etc. 11 14.67 Combustible gases or dust explosion 11 14.67 Fire on raw material transport belt, such as coal, etc. 6 8 Production facilities fire in Stainless steel cold rolling mill, grinding machine, hot rolling mill, etc. 4 5.33 Low flash point Easy-combustible fire of benzene, Coating, etc. 2 2.67 Fire in Office building, Laboratory building, etc 2 2.67 Total 75 100 As shown in the table 1, fires occurred 75 times in steel enterprises, 39 fires related to fault of power supply and distribution system, taking a ratio of 52%. According to fire statistics from the Ministry of Public Security, the incidence of electrical fires account for about 27% of the total number of fire. Thus it is clear that Prevention of electrical fires can not be ignored not only in the steel industries but also in other industries. The following three typical cases of fires cited in power supply and its distribution system of steel enterprises. Case 1 Fire occurred in department of converter steel of a steel company a on February 28, 2000. Burnt area is 1295.4m 2, part of the electrical control system and some equipments were burnt, it made the converter stopped, and 6.157 million Yuan RMB was lost directly. 22 days were spent to repair the system, 50 million Yuan RMB was cost per day. Reason of the fire was verified after investigation, that is the cable connecting to the 3 # converter, after it get out of the cable silo, a part of it located on the ground and was bit by a small animal, this accident produced an arcing fault with a high temperature which made of combustible materials burnt. Case 2 Fire occurred in a substation s cable tunnel of a steel plant on November 8, 1978. It forced the plant shutdown for 36 hours, 13 substations stopped producing too. The total loss is more than 3,800 million Yuan RMB. Reason of the fire is the long-term accumulation of water in Cable tunnel witch caused the insulation performance reduced, at the same, the cable had been working overload for a long time. Finally, a cable was got short-circuit breakdown and shot, it caused cable fire, then the fire spread over the hole cable tunnel, all the cables inside tunnel were burnt out. Case 3 A welding slag caused a cable tunnel fire in a hot rolling factory of steel enterprises on April 19,1994 during its construction. It caused the factory had to stop operation more than 20 days. Although different reasons caused the three typical fires in power supply and distribution system, there is a same scene among these three fires. That is no fire alarm system were installed, then failed to detect a fire, leading to such consequences. These teach us a profound lesson. The loss caused by fire directly, and the loss caused by stop production due to fires, and the social costs of pollution to the environment, etc. had to be considered and to be faced. It gives a serious issue to fire professionals, that is, how to solve fire detection and alarm for power supply and distribution system, how to avoid the fire and the development of fire for the normal production of escort. 2. Fire reasons analysis in power supply and distribution systems From the statistical results of fire cases in iron and steel industry, it can be seen that there are two major fire reasons in power supply and distribution systems: Fire caused by power supply and distribution system itself, including aging, overloading, some unqualified parts, and local current leakage of electricity, etc. Fire caused by external factors of power supply and distribution system, including invasion of external fire source and insulating layers broken by small animals or faults during constructions, etc. Evidently, these fire reasons exist not only in the power supply and distribution systems of iron and steel industry, but also in the power supply and distribution systems of other industry. The rate of incidence of electric fires in our country is around 27%, which is 10 times of the rate of Europe and America. This is a shocking figure that deserves us to consider. After further analysis, the following points are worth for us to consider.

DING Hong-jun and LIU Xiao-lu / Procedia Engineering 11 (2011) 75 79 77 Part of existing power supply facilities cannot satisfy the current power usage demand, which created potential danger of electric fires. In recent years, due to fast economy development and fast growth of living standard in our country, the electricity consumption grows dramatically. Thus, some existing power supply facilities cannot satisfy the fast growth of the electricity consumption, which causes the current power supply lines to overload in a long period of time, causes the insulation layer to age quicker so that the leaking current at some parts of lines starts to increase, ignite the surrounding combustibles and cause fire. The lack of relevant regulations and unqualified construction create the potential danger of electric fires. Due to the lack of necessary regulations on power construction and detection, many power supply and distribution systems are subject to unqualified construction, and external insulation of some electric wires and cables were broken during construction (there are also some unqualified products), which afterwards led to too much leaking current and potential danger of electric fire when being in use. It is determined by the above two factors that under current national conditions effective fire prevention effort has to be made for power supply and distribution systems. However, currently this is not part of our national fire prevention regulations, which also becomes potential danger of electric fires. 3. Approaches to reducing the possibility of electric fires Based on the analysis of the electric fire reasons for power supply and distribution systems, the writer proposes two approaches to reducing the possibility of electric fires in our country. Add fire prevention requirements for power supply and distribution systems in current fire prevention regulations. The national standards Code of design on fire protection and prevention for iron & steel metallurgy enterprises and Code for design of automatic fire alarm system (in revision) have elaborated fire detection and alarm regulations for power supply and distribution systems. Relevant requirements need to be put into other business regulations as well. Configure alarm and control system for electric fire protection scientifically to ensure normal operation of power supply and distribution systems. Alarm and control system for electric fire protection is a fire detection and alarm system which exclusively provides fire prevention safeguard to power supply and distribution systems. The design regulations for automatic fire alarm system, being in revision, requires that alarm and control system for electric fire protection needs to be configured based on building property level, electric fire risk level, and level of target to be protected. It is also required that an alarm and control system for electric fire protection shall consist of part or all of the monitoring equipments, which are leakage current-based electric fire monitoring detector, temperature-based point-type electric fire monitoring detector, line-type heat detector and electric fire monitoring equipments. Leakage current-based electric fire monitoring detector is used to detect leaking current in circuits. The detector will send alarm signal once the leaking current reaches the preset alarming threshold. This detector effectively prevents electric fires from happening when lines are old, insulations are broken or wire terminals discharge irregularly to the ground. This kind of detector shall be installed at the output terminals of the first or the second grade switchboard based on power distribution conditions in a building. Point-type temperature-based electric fire monitoring detector is used to detect the temperature change at the connection part of lines. The detector will send alarm signal once the temperature reaches preset alarming threshold. Because the resistance of the connection part is higher than that of cables, the temperature at the connection part increases most evidently when the line is overloaded. Therefore, electric fire can be forecasted quickly by detecting the temperature change at the connection part. The detector can be mounted in switchboard outside the cable tunnels or at other connection parts. Line-type temperature sensing fire detector can be deployed together with cables due to its continuous detecting characteristic. The detector can not only detect temperature change of cable, but also detect the invasion of external fire source timely. In order to quickly detect fires of case 1 and 3, those fire detectors with smaller effective detection length needs to be selected to use. The national standard fire prevention regulations for steel and metallurgical industry design and design regulations for automatic fire alarm system require that such a detector should responds to fires with diameters of less than 10cm in order for this detector to be able to detect fires of case 1 and 3. When protecting the cables, the line-type temperature sensing fire detector can be connected to the electric

78 DING Hong-jun and LIU Xiao-lu / Procedia Engineering 11 (2011) 75 79 fire monitoring equipment, and not to the fire alarm controller. However, alarm and control units for electric fire protection should be able to send alarm signal to the fire control room. The author believes that the use of electrical fire control system play an active role in reducing the incidence of electrical fires. Here's a case of using alarm and control system for electric fire protection. As had electrical fires before, a furniture city in Beijing installed alarm and control system for electric fire protection. During debugging process of system, the system displays the leakage current is too large more than ten locations. Construction enterprises found leaks according to the system display, Found more than ten locations had the traces of discharge and ignition, the reason is non-standard fittings and the damaged cable insulation around the metal body discharge during Construction process. Think, if you have not installed the system, these risks are hard to find, it would be difficult to avoid the fire. 4. Final sentences Fire is fiercer than a tiger. Too many families lost their family members in fires, and too many properties lost in fires in the past years. The dead people will not alive again, the lost properties will loss forever. The lessons fulfilled with blood teach us to try our best to do a job in fire protection. I believe, combined with implement of Fire Law of the People s Republic of China, with the improvement of the technical specifications in fire, with the improvement of the people s awareness on fire, the ability to fire prevention will increase continually, and the fire rates will decline day after day. 4.1. Structure Files should be in MS Word format only and should be formatted for direct printing. Figures and tables should be embedded and not supplied separately. Please make sure that you use as much as possible normal fonts in your documents. Special fonts, such as fonts used in the Far East (Japanese, Chinese, Korean, etc.) may cause problems during processing. To avoid unnecessary errors you are strongly advised to use the spellchecker function of MS Word. Follow this order when typing manuscripts: Title, Authors, Affiliations, Abstract, Keywords, Main text (including figures and tables), Acknowledgements, References, Appendix. Collate acknowledgements in a separate section at the end of the article and do not include them on the title page, as a footnote to the title or otherwise. Bulleted lists may be included and should look like this: First point Second point And so on Ensure that you return to the Els-body-text style, the style that you will mainly be using for large blocks of text, when you have completed your bulleted list. Please do not alter the formatting and style layouts which have been set up in this template document. As indicated in the template, papers should be prepared in single column format suitable for direct printing onto A4 paper (8.3in x 11.7in/210mm x 297mm). Do not number pages on the front, as page numbers will be added separately for the preprints and the Proceedings. Leave a line clear between paragraphs. All the required style templates are provided in this document with the appropriate name supplied, e.g. choose 1. Els1st-order-head for your first order heading text, els-abstract-text for the abstract text etc. 4.2. Tables All tables should be numbered with Arabic numerals. Headings should be placed above tables, left justified. Leave one line space between the heading and the table. Only horizontal lines should be used within a table, to distinguish the column headings from the body of the table, and immediately above and below the table. Tables must be embedded into the text and not supplied separately. Below is an example which authors may find useful. Table 1. An example of a table

DING Hong-jun and LIU Xiao-lu / Procedia Engineering 11 (2011) 75 79 79 An example of a column heading Column A (t) Column B (T) And an entry 1 2 And another entry 3 4 And another entry 5 6 4.3. Construction of references References should be listed at the end of the paper, and numbered in the order of their appearance in the text. Authors should ensure that every reference in the text appears in the list of references and vice versa. Indicate references by numbers in square brackets [??] in the text. The actual authors can be referred to, but the reference number(s) must always be given. Some examples of how your references should be listed are given at the end of this template in the References section which will allow you to assemble your reference list according to the correct format and font size. There is a shortened form for last page number. e.g., 51 9, and that for more than 6 authors the first 6 should be listed followed by et al. 4.4. Section headings Section headings should be left justified, with the first letter capitalized and numbered consecutively, starting with the Introduction. Sub-section headings should be in capital and lower-case italic letters, numbered 1.1, 1.2, etc, and left justified, with second and subsequent lines indented. You may need to insert a page break to keep a heading with its text. 4.5. Footnotes Footnotes should be avoided if possible. Necessary footnotes should be denoted in the text by consecutive superscript letters. The footnotes should be typed single spaced, and in smaller type size (8pt), at the foot of the page in which they are mentioned, and separated from the main text by a short line extending at the foot of the column. The Els-footnote style is available in this template for the text of the footnote. 5. Copyright All authors must sign the Transfer of Copyright agreement before the article can be published. This transfer agreement enables Elsevier to protect the copyrighted material for the authors, but does not relinquish the authors' proprietary rights. The copyright transfer covers the exclusive rights to reproduce and distribute the article, including reprints, photographic reproductions, microfilm or any other reproductions of similar nature and translations. Authors are responsible for obtaining from the copyright holder permission to reproduce any figures for which copyright exists. References [1] GB50414:2007. Code of design on fire protection and prevention for iron & steel metallurgy enterprises [2] GB50116 (Revised draft):. Code for design of automatic fire alarm system