Series LV AIRFLO. In-duct firing line burner

Similar documents
"NP" & "RG" AIRFLO. In-duct firing line burner

V-Line. Nozzle-mix line burner

"HC" AIRFLO. In-duct firing line burner

APX. Nozzle-mix line burner

DELTA-TE III. Nozzle-mix line burner

INDITHERM. Low temperature gas burners

ECLIPSE AH-MA BURNERS. Air Make-Up Burners. Designed for trouble-free make-up or process air heating. Ready for the world

ECLIPSE AIR HEAT BURNERS Series AH, DAH, TAH & CAH

Specifications of V-Line burners

INDITHERM. Low temperature gas burners

Lanemark Midco HMA2A Series Air Heating Burner and DB Duct Burner System Application Manual

Eclipse AirHeat Burner

LOW NOx MODULATING GAS BURNERS

Eclipse AirHeat Burners

Ecomax. Direct-Fired Self-Recuperative Metallic Gas Burner. Features

TUBE-O-THERM Low Temperature Gas Burners

Specifications of MULTIFIRE burners

The AST Dryer

BURNERS/ FLARES. VAREC BIOGAS 244W Series WASTE GAS BURNER & IGNITION SYSTEM

RS /E-EV C01 SERIES

Bosch Uni 7000F Cast Iron Hot Water Boiler

RS /E-EV C01 SERIES

1 - High-velocity gas burners

25 Years IBS GmbH. Innovative and taylormade burner systems

RIELLO 40 GS/M SERIES

INDUSTRIAL MICRODIFFUSION OIL BURNERS

PBG PACKAGED GAS BURNER

HOT AIR GENERATOR WITH GAS BURNER NA11.45 A GGS. Installation Operation Commissioning Maintenance

Trends for Radiant Tube Heated Strip Lines

PROFIRE -E SERIES BURNERS

TOWER DRYERS TOTA TOT L VA AL V LUE. TOTA ALUE. TOT L SYSTEMS. AL SYSTEMS.

Ronald Sigmond 26 Oct 2016 FLAME MONITORING, GAS HANDLING SYSTEMS AND BURNERS

Hybrid Series. Innovative Heating Solutions continentalheatingandcooling.com

Seasonal Efficiency Longevity Part-Load Efficiency Condensing Operation Fast ROI MODULEX BOILERS MLX-1060 MLX-909 MLX-757

Hybrid Series. Innovative Heating Solutions continentalheatingandcooling.com

Boiler Technical Specifications (2013)

LAARS MIGHTY THERM 2. High Efficiency Boilers and Volume Water Heaters

Direct Fired Heater Model AD Specification

LOW-NOX BURNER RETROFIT CHALLENGE

PYRO-LINE BURNERS 126LX 6LE 12LS DESCRIPTION MODEL: 3201

Boiler Basics. Design and operation

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

GAS-FIRED PRESSURIZED LOW INTENSITY INFRARED HEATERS SERIES TLP

Madhu Honap HONEYWELL THERMAL SOLUTIONS INTRODUCTION

Design and Application Details

High Performance Diesel Fueled Cabin Heater. Abstract

Products & Services. DISTRIBUTOR & FOREHEARTH SYSTEMS

TECHNICAL DATA MOBILE WASTE INCINERATOR

Module 5: Combustion Technology. Lecture 38: Combustion Burners

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

fans & heaters SIMPLE, ROBUST AND RELIABLE

COMBUSTION APPLIANCE SAFETY INSPECTION FOR VENTED APPLIANCES*

Product Data BW9 WATER BOILER SERIES B

LAARS PENNANT. Economical efficiency for greater savings

Eclipse AirHeat Burners AH Series version 2.00 (Patent Pending)

Commercial Tankless Rack System

Pulse Jet Baghouse ASTEC PULSE JET BAGHOUSE. for Asphalt Facilities

We offer ceramic radiant heaters and infra-red radiant tubes.

Commercial Tankless. Rack System TANKLESS WALL MOUNT LIGHTWEIGHT EXPANDABLE REDUNDANCY EASY FIELD INSTALLATION EASILY INTEGRATE STORAGE WARRANTY

Fire Risks in our Woodshops. Sam Altshuler January 2018

Gas Safety. Syllabus. For 120kW. Class B gas fitter. Certificate of qualification examination

HYBRID SERIES FURNACES. napoleonheatingandcooling.com

OIL AND GAS INDUSTRY

Commercial Tankless Rack System

Technical Document Condensing hot water boilers

MYdens T 5WARRANTY 1:20. Ti TITANIUM. commercial gas condensing boilers. boilers from 60 to 280 kw AISI 316 YEARS WORKING PRESSURE HEAT EXCHANGER

Design Guide 111 9/25/2008. Eclipse Winnox Burners WX Series Version 1

Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B TYPE B 23

FLAT FLAME AND EXCESS AIR BURNERS

Design Guide /12/2008. Eclipse RatioAir Burners RA Series Version 1

Originators of the Flexible Water Tube design

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

Originators of the Flexible Water Tube design

PETRO-CANADA OIL AND GAS. FIRE-TUBE IMMERSION HEATER OPTIMIZATION PROGRAM & Field Heater Audit Program

Process Heat Equipment & Combustion Field Services Guide

C. Shop Drawings: For boilers, boiler trim, and accessories. Include plans, elevations, sections, details, and attachments to other work.

SOLID. STATE. Commercial Tankless. Rack System TANKLESS WALL MOUNT LIGHTWEIGHT EXPANDABLE REDUNDANCY EASY FIELD INSTALLATION EASILY INTEGRATE STORAGE

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

Commercial Tankless Rack System

wall-mounted boilers, water heaters and pool heaters from 15 kw to 140 kw

A. American National Standards Institute (ANSI): Establishes requirements applicable to certifying direct gas-fired heaters.

Revitalize Building Mechanical Systems (4619)

GAS AND PELLET BURNERS

F-Series Tower Drying

Table Top Patio Heater

PROPOSED October 15, 2013

AGUAdens TM 100% residential condensing D.H.W. wall-mounted water heaters ( litres) AISI 316 D.H.W. WORKING PRESSURE TITANIUM CONDENSING

Engineering Bulletin. Gas Heat. for M-Series and T-Series Climate Changer Air Handlers CLCH-PRB010-EN. March 2004

Commercial Tankless Rack System

FGR. Installation, Operation and Startup Instruction Manual FOR FLUE GAS RECIRCULATION SYSTEM. FGR-8 through FGR-22 (25 HP to 1000 HP)

ecodry Figure 1 - Process Diagram ecodry B General Process Description

CONDENSING HIGH EFFICIENCY BOILERS

CHAPTER 15: FIRE PREVENTION & AWARENESS POLICY

MULTI-LINK UP TO 20 UNITS COMMON VENT UP TO 8 UNITS COMPLIES WITH LEAD FREE STANDARDS SAFETY FEATURES:

EXCESS AIR BURNERS XNM SERIES FEATURES APPLICATIONS DESCRIPTION. Bulletin E3502 rev05 31/01/00

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER

OnePlus. Packaged Air Handling Units for Ducted Installations. Caring for the environment!

INTRODUCING THE BRADFORD WHITE 24/7 EXPERT SUPPORT CENTER. TABLE OF CONTENTS. Technical Support: Warranty Support:

VPC Gas Cabinet Heater Range Architects of your environment. heating ventilation air conditioning

SECTION DIRECT GAS-FIRED INDUSTRIAL HEATING AND VENTILATING UNITS

Transcription:

Series LV AIRFLO In-duct firing line burner Duct burners - LV AIRFLO 4-21.4-1 Series LV AIRFLO burners provide stable, efficient, raw gas operations in air streams with relatively low duct velocities. Duct static pressure drops may be as low as 0.5 mbar. Produces clean and odor-free combustion with natural or propane gases. Air stream temperatures upstream of a Series LV AIRFLO burner can be up to 566 C. Low air stream oxygen levels can be tolerated without a need to add primary combustion air to the system. Modular burner design provides burner assembly configurations and total heat release for maximum application flexibility. 17 varieties of Series LV AIRFLO burners available, each optimized in materials and/or performance factors to match your specific application requirements.

4-21.4-2 Product description Series LV AIRFLO principle 1) Fresh air 2) Gas 3) Hot air MAXON Series LV AIRFLO burners are designed for heating process air in motion. An iron or aluminum bronze body which serves as the gas manifold is drilled to discharge the fuel gas between diverging mixing plates. The entire burner assembly is mounted inside a process air duct directly in the air stream being heated. The air stream passes across the burner and through the mixing plates and is used as combustion air. Carefully controlled mixing plate aeration patterns give progressive mixing, superior cross-ignition and flame retention across the entire burner assembly length. The Series LV AIRFLO burner burns clean and odor-free with low levels of NOx production. Correctly sized process air ducts and the resulting duct static pressure drop across the burner are the keys to successful operation. Normal capacities vary widely with the application and the duct pressures. The fuel used and the design velocities will affect the burner turndown. Modular design permits the burner shape and total heat release to match the application needs. Performance data varies depending upon temperature of air upstream and downstream of the burner assembly, the percentage of oxygen (by volume) in the passing air stream, and the allowable duct static pressure drop across the Series LV AIRFLO burner.

4-21.4-3 Available product sizes Several varieties of Series LV AIRFLO burners are offered. Each type is optimized for a specific type of application. All varieties can be used as raw gas type systems or partial air/gas premixture for applications where higher upstream temperatures and/or lower oxygen levels are involved. LV-NP1 AIRFLO burner with its gray iron body and #321 stainless steel mixing plates is the most economical choice for a raw gas burner system for fresh air heating with low heat release per lineal foot and outlet temperatures up to 540 C. For upstream process air temperature up to 315 C. LV-3G AIRFLO burners have gray iron bodies and #321 stainless steel mixing plates. Four different versions are available, either for raw gas burner applications or those requiring a partial air/gas premixture system and/or outlet temperatures up to 540 C. For upstream process air temperature up to 315 C. LV-4D AIRFLO burners have a ductile iron body and #310 stainless steel mixing plates for applications with outlet temperatures up to 815 C. For upstream process air temperature up to 540 C. LV-5D AIRFLO burners complement their ductile iron bodies with Hastelloy-X mixing plates for use in applications with up to 930 C outlet temperature requirements. For upstream process air temperature up to 540 C. LV-5B AIRFLO burners have an aluminum bronze body casting with Hastelloy-X mixing plates for use with applications requiring up to 930 C outlet temperatures. For upstream process air temperature up to 565 C. Typical burner data Fuel: natural gas at 15 C with 10.9 kwh/nm 3 HHV - sg = 0.6 [1] Combustion air: 15 C - 21% O 2-50% humidity - sg = 1.0 [1] Stated pressures are indicative. Actual pressures are a function of air humidity, altitude, type of fuel and gas quality. Burner size LV-NP1 LV-3G LV-4D LV-5D LV-5B Maximum capacity per foot [2] kw 175 730 730 730 730 Minimum capacity per foot [2] kw 9 22 22 22 22 Natural gas differential pressure [3] mbar 10 70 70 70 70 Flame length [4] m 0.3 2 2 2 2 Pressure drop process air [5] mbar 0.5-6.2 [1] sg (specific gravity) = relative density to air (density air = 1.293 kg/nm 3 ) [2] Maximum and minimum capacities are highly dependent upon the application. Check Specifications of LV AIRFLO burners for more information. [3] Natural gas differential pressure at burner inlet at maximum stated burner capacity. The stated values are valid for burners with standard gas drillings. Refer to Specifications of LV AIRFLO burners for gas differential pressures to be used with alternative gas drillings. [4] Flame length at highest capacity and highest process air pressure drop across the burner when firing on fresh air. The flame length and flame aspect are highly dependent upon factors such as process air velocity and process air oxygen content. Refer to Specifications of LV AIRFLO burners for more information. [5] Stated process air pressure drop across the burner should never exceed the specified range in this table. In some specific applications, the process air pressure drop range could be even more narrow.

4-21.4-4 Applications Series LV AIRFLO burners are designed for stable, efficient, raw gas operations in air streams with relatively low duct velocities. Duct static pressure drops may be as low as 0.5 mbar or up to 6.2 mbar. Elevated air stream temperatures approaching the Series LV AIRFLO burner can be as high as 565 C. Reduced oxygen levels as low as 12% (by volume) are tolerated without a need to add primary combustion air. For applications with low oxygen levels, a partial premixture must be added through the system. Typical applications include thermal incinerators, cogeneration, spray dryers, hot air generators with variable flows, rotating drum dryers and calciners. 1) LV AIRFLO burner 2) Combustion chamber 3) Gas pipe train 4) MAXON shut-off valves 3500 kw hot air generator with 9 ft LV-4D AIRFLO burner to be used for the production of titanium dioxide

4-21.4-5 Dimensions and weights LV-NP1 AIRFLO burners 1 3 1) LV-NP1 AIRFLO burner 2) LV-NP1 12 inch straight section 3) Typical end view for LV-NP1 burner sections 2 B A D C E LV-3, -4, -5 AIRFLO burners 1) LV-3, -4 & -5 AIRFLO burner 2) LV-3 12 inch straight section 3) Typical end view for LV-3, -4 & -5 burner sections 1 2 A 3 B C E F D Dimensions in mm unless stated otherwise Burner size A B C D E F Weight kg LV-NP1 12 straight section 305 174 178 27 86 --- 6 LV-3, -4 & -5 12 straight section 305 189 190 49 105 66 10

4-21.4-6 Typical emissions MAXON Series LV AIRFLO burners are especially designed to meet the high demands of most of the local standards on air quality of direct fired process air heating applications worldwide. If correctly used within the performance limits as described on page 4-21.4-7, both CO and NOx will remain far below the limits as determined in most standards. Exact emissions performance may vary in your application. Contact MAXON for information on installation specific estimates or guarantees. No guarantee of emissions is intended or implied without specific written guarantee from MAXON. Read Specifications of Series LV AIRFLO burners for complete information on these burner types.