WH7016E Thermostat Product Manual

Similar documents
SA-3841 User Manuel. 1U 4 Fans Unit with Thermostat Sensor. Version 1.1 Copyright All Rights Reserved

WILLHI WH1436H Digital Humidity Controller Manual (NEW VERSION)

Toll Free: Tel: Fax:

Plug-n-Play Humidity Controller. IHC-200 User Manual. Version 1.3s. Inkbird Tech. Co., Ltd.

Refrigerated air dryers

JDDT1 - Single Stage Digital Thermostat

Programmable Outlet Thermostat. User Manual. Version 1.5s. Inkbird Tech. Co., Ltd.

ST710-KHJV.03. Wiring diagram. Product description. Temperature controller. Order number

Refrigeration and Air Conditioning Technical leaflet. Electronic controller EKC 201 and EKC 301

ST Wiring diagram. Product description. Four-stage controller. Order number

FX BLAST CHILLER ISO ISO 9001

MODEL URS-1: FACTORY RETROFIT PROGRAM

Connect the power supply and equipment to supply to the controller is displayed for the

ST Wiring diagram. Product description. Standard temperature controller. Order number

TDF 15 MICROPROCESSOR-BASED DIGITAL ELECTRONIC THERMOCONTROLLER. OPERATING INSTRUCTIONS Vr. 01 (ENG) - cod.: ISTR TECNOLOGIC S.p.A.

5 Parts. The Manual Is Divided Into. 1 Quick Gide to Use. Part. Part 2 Temperature Controller manual. Part 3 Programmable Temperature

Table 1. Serie of Digital Room Thermostats.

Parts introduction FRONT BACK

Commercial Refrigerator Service Manual

URS-1 SERVICE AND PARTS MANUAL SERIAL NUMBERS: UP TO

Dixell Installing and Operating Instructions release 7.0

Temperature-Relay TR210

ETN-24-SUPER-SF Series

Electronic Controls Handbook Programming Flow Charts & Parameter Lists for

Commercial Freezer Service Manual

IN NOURISHING SECURITY.

MINITOP Refrigerated Self-Service Display underneath

DIMENS. MIN TYPICAL MAX A 71.0 (2.795) 71.0 (2.795) 71.8 (2.826) B 29.0 (1.141) 29.0 (1.141) 29.8 (1.173)

OMNITOP Refrigerated Display with Ventilated Cooling

XC1008D -XC1011D- XC1015D and VGC810

Thermometers and temperature controllers

ER52 - Evaporator Controller

Ocean Breeze Model QU700 Programmable Digital Touchscreen Climate Control

INTELLIGENT ROOM THERMOSTAT

DIGITAL TEMPERATURE RELAY TR-100

OPERATING INSTRUCTIONS. G214 Software - Version 4

Ocean Breeze Model QU700 Programmable Digital Touchscreen Climate Control

XWA11V. Walk-In Temp / Door /Alarm / Light Module

Instruction FH-CWP Thermostat

Settings and Maintenance of the CombinAir

Wall Hung Boiler Room Thermostat OR30 OT Thermostat

User Guide. Stainless Steel Filter Housing Heater

Sf2+HF2 Sf2 Sf1 + Hf1 Sf1. 1 ON Fan1 enabled (only for XC30CX) 2 ON Fans enabled (only for XC30CX) kpa. Time

BWAC Steuerung. Kochendwasser- Energiesparreinigung. Art.-Nr Version 1.0

EC 6-295P220S001. smart guide 2 OPERATION. 2.1 How to turn the instrument ON/OFF. If you have to turn the instrument ON/OFF:

SAT- 3 Installation Setup Guide

T-32-TS Touchscreen Thermostat. Installation Manual

Instructions of use and maintenance page 2 Electric and refrigerating diagrams page 3 Manual of the thermostat page 4 Spare parts page 6

GreenCon On/Off Room Thermostat

XC10CX and XC30CX. Digital controller for CDU management 1. GENERAL WARNING 4. FRONT PANEL COMMANDS 2. GENERAL DESCRIPTION

OPERATION MANUAL RK-2006LPP AUGER FITTED SOLID FUEL BOILER TEMPERATURE CONTROLLER. Version DC19

GreenCon On/Off Room Thermostat

Operating Instructions XWA11V XWA11V. Walk-In Temp / Door /Alarm / Light Module

CAREL IR33+ CONTROLLER

TOQUE BLANCHE GRANDE CARTE

Installation & User s Instructions

The new generation of cold room solutions. CAMAlarm Alarm Alarm

12. NOTES. SC-20 TEMPERATURE CONTROLLER. 2.0 version

Comfort System T-21-P Touchscreen Thermostat Installation Manual

Smart Temp. ApolloP/n Installation Manual. Version 1.0

ECH 985. Electronic controller for heat pumps used in residential hot water application

Instruction Manual for HX-DX and HX-DXHP Heat Exchangers 3 / 2017

1 measurement signal input 4-20 ma for connection to an external gas sensor 5 freely programmable alarm switching points per measuring point

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

SECURIT 700L USER MANUAL

DPC-1 Programmable digital thermostat with communication Versión 2.0. Technical Information. Ref: N

Janfire Pellet Burner Boiler. for single / double burner management (Version 1.1)

ETN-24-SUPER-PROG (US Program - Celsius)

Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications

GREEN LEAF PROGRAMMABLE THERMOSTAT FOR ELECTRICAL FLOOR HEATING INSTALLATION INSTRUCTIONS. EN-RaychemGreenLeaf-IM-EU0209 THERMAL BUILDING SOLUTIONS

XR60C ,QVWDOOLQJDQG2SHUDWLQJ,QVWUXFWLRQV. Digital controller with defrost and fans management 1. GENERAL WARNING 4. FRONT PANEL COMMANDS

INSTALLATION MANUAL. Need Help? This manual covers TopTech models: TT-N-721 and T721. Power Type. Thermostat Applications Guide.

Installer Manual KNX Touchscreen Thermostat

Sf2+HF2 Sf2 Sf1 + Hf1 Sf1. DLT Prb. Ground

Introduction. OM-THA2

CAREL CONTROLLER. Programming Instructions HOW TO CHANGE LEVEL 1 CONTROL SETTINGS HOW TO CHANGE LEVEL 2 CONTROL SETTINGS

Temperature and moisture controller for cold room store

XWA11V-KIT Walk-In Temp / Door /Alarm / Light Module with Mounting Box and Wiring

Quickheat 30 weather compensated boiler control

DataSheet. Thermocouple Logger

OPERATION AND MAINTENANCE MANUAL

Operating Instructions XWA11V. XWA11V-KIT Walk-In Temp / Door /Alarm / Light Module with Mounting Box and Wiring

Dough Retarder Prover. Service Manual

OPERATION MANUAL RK-2001W2 SOLID FUEL FIRED BOILER TEMPERATURE CONTROLLER. Version 9A15

DataSheet. Thermocouple Logger

Semi flush-mount room thermostats

Declaration of Conformity no. 56/2012

PL-1 Thermostat User s Guide

TV2 Clean Room Monitor

INSTALLATION & USER MANUAL

KONTROL INVIKTA Double

TV2 Room Pressure Monitor Quick Start Guide

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

Dohse Aquaristik GmbH & Co. KG. T-Control Pro. Item no Status: 03/2013. Dohse Aquaristik GmbH & Co. KG

dixel Installing and Operating Instructions PRELIMINAY

Label Displayed temperature Pb1 if the P4 parameter is set to 0, 1 or 2, room temperature if the P4 parameter is set to 3, incoming air temperature

Digital Controller XR70CX. Operating Manual. 5/10 Rev. B

INSTALLATION MANUAL. Need Help? This manual covers the following models: T725. Power Type. Thermostat Applications Guide. Page.

TH146-N-2H1C. 1. Introduction. 2. Installation. 1.1 Applications. 2.1 Control Module (CT280-2H1C) 1.2 Supplied Parts. 1.

Electronic Pellet Burner Controller NPBC-V3-1

Transcription:

WH7016E Thermostat Product Manual Shenzhen Willhi Electronics Co., Ltd. Tel :0755-29539385 Fax :86-0755 -2953 9395 Technical support: Engineer Tian

1 Installation opening size: 2 Wiring diagram: 1 2 3L Power dont touch NTC 4N 5 6 7 8 load heat eg mat SENSOR 220v Terminals 1 and 2: Normally opened contact of relay Terminals 3 and 4: Connect the power Terminals 5 and 6: The factory parameter settings of thermostat can be locked after a short circuit, the user can not modify. Terminals 7 and 8: Temperature connection sensor Note: The load refers to the heating or cooling equipment on control. 3 Electrical performance: Temperature measurement range: -9.9 ~ 99.9 Temperature control range: -9.9 ~ 99.9 Temperature measurement error: ± 0.5 Sensor Type: NTC (10K/3435) Control accuracy: 1 Working voltage: AC/DC12V AC220V AC110V Working current: <2W Relay contact point current: AC 7A/220V Data storage : Yes Working temperature: 0 ~ 50 Storage temperature: -10 ~ 60

4 Key Instructions: 1. RST: Press RST key to switch on and off, press the RST key on the power-off state once to turn on, on the power-on state, press the RST key for three seconds and hold on, then it will be off. 2. SET: A: Press the SET key once to enter the temperature control setting, press or button to adjust, press or button for three seconds and hold to enter the fast adjusting mode, press the SET key again to exit setting mode. B: Press and hold SET key for three seconds to enter the system menu settings, press the or key to select the adjustment menu, press SET key once to enter the appropriate parameter settings, press or to adjust the parameters needed to be modified, after being adjusted, press the RST key to exit, or exit as the system delay for 5 seconds. : Up key : Down key Operating Instructions: 5 LED Status Description: The WORK lights at the left side of the screen is used as working indicator lights, flashing is to indicate the delay of cooling or heating, if the LED is always on,it indicates it is on the status of cooling or heating. The SET light at the left side of the screen lights is used as setting indicator lights, if the LED is always on,it indicates it is on the status of setting.. Function Instructions: Press RST key to open the thermostat, on the running status, press this key for 3 seconds, then the thermostat can be turned off. Cooling, heating function: Cooling Mode: When the measured temperature is higher than or equal to the set value + hysteresis, the relay picks up to start the output; When the measured temperature below the set value, the relay off and close the output. Heating mode: When the measured temperature is higher than or equal to the set value, the relay off, turn off the output; When the measured temperature below the set value - hysteresis, the relay picks up to start the output. Example for Setting: If it is set to heating mode, set the temperature to 25 degrees, hysteresis is set to 5, then when the measured temperature is higher than or equal to 25 degrees, the relay is off, close the output. When the temperature is below 20 degrees, pick up the relay again, to start the output. Example for Setting: If it is set to cooling mode, set the temperature to 25 degrees, hysteresis is set to 5, then when the measured temperature is below 25 degrees, the relay is off, close the output. When the temperature is higher than or equal to 30 degrees, pick up the relay again, to start the output. Cooling, heating mode setting: the screen appears "HC" code, press the "SET" key to display the working mode, press the " " or " " to adjust the display, C means cooling mode; H means heating mode. Hysteresis function: Hysteresis setting limits the maximum interval between the opening and stopping, this machine minimum interval between the opening and stopping is

1, the maximum is 15. Hysteresis settings: with " " or " " key adjusted to the screen, appearing "D" code, press the "SET" key to display the hysteresis set value, press " "Or" "key to adjust the parameters. Temperature calibration funtion: When there is deviation between the measuring temperature and standard temperature, use the temperature calibration function, make the machine measurements value consistent with the standard temperature, the after calibration temperature= the before calibration temperature + calibration value (calibration value can be positive number, negative number, and 0). Temperature calibration settings: with " " or " " key adjusted to the screen, appearing "CA" code, press the "SET" key to display the temperature calibration settings, press " "Or" "key to adjust the parameters. For example: When we measure the probe temperature was 25 degrees,it displays 25 degrees as the CA is 0, it displays 26 degrees as the CA is 1, it displays 24 degrees as the CA is -1. This function is generally applied when the probe can not measure directly the measured object. For example, we place the probe at the outside of a cup to measure its water temperature, we need to adjust the CA parameters because of the heat loss of the cup, so that the display temperature can be in accordance with cup temperature. Delay Protection Funtion: In the cooling mode, the first power on, when the measured value above the set value + hysteresis value, the machine will not immediately start cooling, it needs to set the delay time, then the machine can run to start cooling; once the interval between two cooling is larger than the delay time, the machine immediately starts cooling, once the interval between two cooling is less than the delay time, the machine must run the remaining delay time to start cooling. The delay time is started to calculate from stopping the machine. The delay time of heating mode is as same as the cooling mode. Note: It is recommended that only the device that use compressor cooling can use the delay start function, the user who don't need delay start function please set this parameter to 0. Delay Protection Setting: with " " or " " key adjusted to the screen, appearing "PT" code, press the "SET" key to display the delay setting value, then press the " "or " "key to adjust the parameters. Upper and lower limit functions: The setting of HS and LS limit the set range of control temperature point, for example: HS is set to +15, LS is set to -10, the control temperature can only be adjusted between -10 and +15, when the control temperature to -10 then press " " key, the display will remain on the status of -10 and not decrease; when the control temperature to +15 then press " " key, the display will on the status of 15 and not incease. If the set point outside this range, it needs to firstly change the value of HS and LS, then it can be achieved. Upper and lower limit settings:

with " " or " " key adjusted to the screen, appearing "HS" or "LS" code, press the "SET" key to display the upper or lower limit set value, Then press " " or " " key to adjust the parameters. HS means upper limit. LS means lower limit. For example: the upper and lower limits are used to limit the range of control temperature that can be set, such as: LS is 10, HS 20, then press the SET key to adjust the temperature control, it can only be varied between 10 and 20. High temperature alarm: If the measured temperature> set temperature + AH alarm output relay. Thermostat alarm will sound, the display alternately shows H and the current temperature. Alarm, press any key to stop the alarm and relay output. High temperature alarm settings: Press "SET" button and hold more than 3 seconds to enter the menu display, with " " or " " button transferred to the screen appears "AH" code, press the "SET" key to display the high-temperature alarm settings, press " "or" "key to adjust the parameters Low temperature alarm function: If the measured temperature "set temperature-al when the alarm output relay. Thermostat alarm will sound, the display alternately shows L and the current temperature. Alarm, press any key to stop the alarm and relay output. low temperature alarm settings: Press "SET" button and hold more than 3 seconds to enter the menu display, with " " or " " button transferred to the screen appears "AL" code, press the "SET" key to display the low temperature alarm settings, press " "or" "key to adjust the parameters Menu code selection: Symbol Details Setting Factory Units range settings HC Heating / H/C C cooling D Hysteresis 0.1~15 1.0 LS The minimum -9.9~99.9-9.9 set limit HS The maximum -9.9~99.9 99.9 set limit CA Temperature -5.0~+5.0 0.0 calibration PT Delay time 0~10 1 Minutes AH High temperature 0~15 1.0 alarm AL low temperature alarm settings 0~15 1.0 6 fault tips: 1)When the sensor disconnected, the screen displays --- and close the heating wire 2)When the sensor detects the temperature is below -9.9 degrees, the screen displays LLL 3)When the sensor detects a temperature higher than 99.9 degrees, the screen displays HHH 7 Caution for using: Cooling, heating load must not exceed the output contact capacity, or it may result in machine damage and cause a fire.

Various connecting wire must be well connected with the terminal, otherwise, it would result in reducing the reliability of machine. When connecting the wire, please separate power supply, relays, sensors, otherwise it will damage the machine.