CABLEPACK & EXZHELLENT TRIPLAN. Easy installation

Similar documents
FUMEGUARD TM QUALITY APPROVED CABLES. Cables Limited MADE IN IRELAND SINCE 1934 IDH CABLES LIMITED LOW SMOKE HALOGEN FREE CABLES

High Performance LSZH Fire Resistant Cable

Telecommunication Cables

600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores)

IEC UNE DESIGN. 1. Conductor. 2. Insulation. Cross-linked polyethylene (XLPE) 3. Outer sheath. Flexible PVC, black colour.

Metal Woodprint The natural look

Catalogue Telecommunication Cables INTRODUCCIÓN

Power Cables. Introduction 3 RV 4 RVMV 5 RVSV 6 RVFV 7. ELECWIRES 2 Page

AFIREFENIX SZ1-K 0,6/1 kv PH120 (AS+)

Metal Woodprint The natural look

Manusa Automatic. Doors. Safety beyond the Standard. EN16005 Power operated pedestrian doorsets. Safety in use. Requirements and test methods.

This document is a preview generated by EVS

Caledonian Flame Retardant Coaxial Cables

Cable technology for highest safety requirements

Flexflame. Arctic Grade Cables for Extreme Conditions. Photo: Sakhalin Energy Investement Company Ltd.

GUARDIANTM QUALITY APPROVED CABLES. Cables Limited MADE IN IRELAND SINCE 1934 IDH CABLES LIMITED MECHANICALLY PROTECTED CABLES

BS /1000V XLPE Insulation LSZH Sheath Cables

ISO INTERNATIONAL STANDARD. Non-destructive testing Penetrant testing Part 2: Testing of penetrant materials

LSOH Wiring Cables. LSOH Conduit Wire (HO7Z-R) Low Voltage (450/750 V) Cable Approvals. Key Applications. Conductor. Insulation. Core Identification

CABLES FOR ALARM AND SAFETY SYSTEMS

This document is a preview generated by EVS

LSOH Flexible Cables

Traction Cable Radox 3 GKW

Catalogue Power Cables

Fire-Resistant. Automatic Doors

Sýnishorn Fire resistance test for service installations - Part 1: Ventilation ducts

For more information on Tarkett go to

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

AutoM Click to go to the page. AutoM Auto Shaker Filter

Firetuf Cables ZERO HALOGEN, LOW SMOKE (0HLS ) CABLE

Firetuf Cables ZERO HALOGEN, LOW SMOKE (0HLS ) CABLE

RAILWAY APPLICATIONS - ELECTROTECHNICAL EQUIPMENT FOR ROLLING STOCK PART 5: ELECTROTECHNICAL COMPONENTS RULES FOR HV FUSES (IEC :2003)

Camping tents (ISO 5912:2011)

This document is a preview generated by EVS

OIL & GAS INDUSTRY OTHER INDUSTRIES

Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design.

HELKAMA. Optical Fibre Cables

STANDARDS INSTALLATION. Certificate No 077m

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Photovoltaic Cables EN H1Z2Z2-K

BS FP600 achieves the maximum 120 minute rating under the BS test conditions, which is required for fire fighting applications.

speed pipe indoor system. Secure indoor networks.

CIRCA Ceiling Range. Ceiling products designed to meet a wide range of applications and compliment any ceiling décor

ENHANCED FIRE PERFORMANCE CABLE

Double insulated, electron-beam cross-linked, halogen free photovoltaic wire sunlight resistant. Single conductor, flame retardant insulation.

DNVGL-CP-0402 Edition February 2016

The Quality Connection. BETAflam Fire Resistant Safety Cables

Copper LAN cable. This specification describes the general requirements for AMP NETCONNECT* copper LAN cable.

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

AFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:

GRINNELL Rapid Installation Pivot-Bolt

The intelligent alternative for flue gas venting systems

Core identification code. J-YY...BD Indoor Cable. J-YY...BD Indoor Cable. VDE 0815 Mutual capacitance. J-YY...BD Indoor Cable. Cu conductor 0.

BS EN :2004. Test On Electric And Optical Fibre Cables Under Fire Conditions. WF Report Number. Date: 14 th November 2008.

AFUMEX LSX BASEC APPROVED LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:

COMBIFAB F Fan The flexible fan for dust extraction systems in all industries

CORFLEX. TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES

Heat Sensor Cable Alarm Units DT650L / DT950L

SPECIAL ELECTRICAL AND OPTICAL CABLES

Easy to install in ducts, tunnels and trenches by means of compressed air or pulling wire. Suitable for direct burial (crush 400 N/cm).

Total Fire Solutions. Includes BS 8519 and the updated BS :

Lloyd s Register Type Approval System Test Specification Number 3

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

BS EN :2004. Test On Electric And Optical Fibre Cables Under Fire Conditions. WF Report Number. Date: 14 th November 2008.

Author Owner Issue Authority Name: Gordon MacKenzie Title: Senior Engineer Engineering Design and Standards

Installation, operating and maintenance ARIA

Textile fire protection closures EI 30/90

Electric cables Low voltage energy cables of rated voltages up to and including 450/750 V

THE TRUE FIRE SURVIVAL CABLE

Construction Products Regulation (CPR) and BS 6701

600/1000V XLPE Insulated, LSZH Sheathed, Double steel tape Armoured Power Cables (3 Cores)

(Notices) EUROPEAN COMMISSION

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

Fire Resistant Cables

Ø 1000 * 588 mm 50 kg

This document is a preview generated by EVS

This document is a preview generated by EVS

FIRE RESISTANT CABLES

This document is a preview generated by EVS

CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES

This document is a preview generated by EVS

C6 Premium. C6 Premium Copper Systems from Infinique is premium performing Class E / Category 6 Data Communication

This document is a preview generated by EVS

FIRE PERFORMANCE CABLE

Product Specification CAT 6 UNSHIELDED PATCH CORDS

Extended Producer Responsibility A global perspective. Andrew Sweatman

Flame Retardant Overall Screened Instrumentation Cables (multicore)

Data sheet OpDAT universal cable 1x24 OM4 - bend insensitive

DNVGL-CP-0401 Edition February 2016

Installation Instructions

CONTENTS. Introduction Customer Service BS codes of practice BS Fire Performance Cable Selection Guide... 7

Shipboard & Offshore Cables

ILNAS-EN 50304:2001. Electric ovens for household use - Methods for measuring the energy consumption

Introduction.

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Energy Division Heat-shrinkable joints for halogen-free, flame-retardant and fire-resistand cables up to 1 kv

This document is a preview generated by EVS

DNVGL-CP-0399 Edition March 2016

User and maintenance manual

This document is a preview generated by EVS

Transcription:

CABLEPACK & EXZHELLENT TRIPLAN Easy installation

CABLEPACK ENERGY AND TELECOM PRE-WIRED CONDUIT CABLE SYSTEM Cablepack is a pre-wired conduit system, made of a corrugated conduit with the insulated conductors already inside, that saves time and reduces waste as it combines in one single step the operation of conduit installation and subsequent wiring of the insulated conductors within the conduit. Cablepack simplifies the process of installation by reducing labour costs and time-to-completion while at the same time avoids some of the problems related to this type of installation: wiring difficulties due to complicated and unknown conduit paths, errors in the combination of conduit and insulated conductor types, compliance with project and regulation requirements, Cablepack is the most cost effective solution as it saves material, time and labour improving the efficiency and profitability of your business. Cablepack includes solutions for energy and telecom cable installation, with a complete range that covers most of the indoor cable installation under conduit. Conduit characteristics: Cablepack complies with all requirements included in standards EN 61386-1 and EN 61386-22 (corresponding international standards IEC 61386-1 and IEC 61386-22). Resistance to compression is 750N. Characteristics Code Standards Compression resistance 3 Medium (750 N) Impact resistance 4 High (6J) Minimum temperature of installation and service 2-5ºC Maximum temperature of installation and service 2 +90ºC (1) ICTA 3422 Bending resistance 1-2-3-4 Any of the referenced codes Electrical properties 0 Not declared Resistance to penetration of solid objects 5 Protected against dust Resistance to water ingress 3 Protected against raining water Resistance to corrosion of metallic and combined tubes 2 Medium protection for inner and outer sides Resistance to traction 0 Not declared Flame retardant 1 Flame retardant Resistance to suspended loads 0 Not declared (1) For ordinary pre-wired conduits in factory fitted installations (walls, ceilings and false ceilings), a maximum installation temperature and service code 1: + 60ºC is accepted.

CABLE CHARACTERISTICS: ENERGY GENLIS Types: H07V-K H07V-R H07V-U Rated voltage: 450/750 V Design standard: HD 21.3, IEC 60227-3 Flame retardant: EN 60332-1-2, IEC 60332-1-2 Fire retardant: EN 60332-3-24 Cable approvals: COAXIAL Type: CABICTEL Coaxial Digital TV 75 ohm Flame retardant: EN 60332-1-2, IEC 60332-1-2 TELEPHONE Voltage: CABICTEL Telephone 250 V Flame retardant: EN 60332-1-2, IEC 60332-1-2 Note: Installation and current ratings for energy cables: standard IEC 60364-5-523 includes current ratings for wiring systems.

EXZHELLENT TRIPLAN, THE EASIEST SOLUTION FOR THE MOST DIFFICULT INSTALLATIONS General Cable intends to make your life easier. That s the reason why we have developed a solution that is adaptable to all your needs and facilitates the installation processes in the fastest and simplest way: EXZHELLENT TRIPLAN. EXZHELLENT TRIPLAN is composed of three insulated conductors placed inside a halogen-free non-circular extraflat conduit with individual interchangeable compartments for each insulated conductor. EXZHELLENT TRIPLAN contributes with many advantages to the electrical wiring installation: > Reduces the installation time. > Reduces waste. > Allows the installation of lighting points where the wall or ceiling forging prevents the installation of conventional conduits. > Avoids carrying out chases in walls or ceilings. > Its extra-flat shape allows easy covering with a simple layer of plaster. > Allows easy change or replacement of the inside cables. > Separate compartments isolate cables from one another. Moreover, EXZHELLENT TRIPLAN is a Low Fire Hazard product: the protective conduit and the cables inside comply with all requirements of EXZHELLENT XXI 750 V range: Flame retardant Fire retardant Halogen free low acidity low smoke EN 60332-1-2 en 60332-3-24 en 50267-2-1 en 50267-2-2,3 en 61034-2 IEC 60332-1-2 IEC 60332-3-24 IEC 60754-1 IEC 60754-2 IEC 61034-2

Conduit characteristics: The conduit is designed and complies with all requirements according to standard EN 50085-2-1 with the following minimum characteristics: Characteristic Grade Resistance to impact Resistance to compression Medium 750 N Minimum installation and service temperature -5 ºC Maximum installation and service temperature 60 ºC Electrical properties Resistance to penetration of solid objects Resistance to water penetration Resistance to flame propagation Insulation Not declared Not declared Flame resistant CABLE CHARACTERISTICS: exzhellent XXI 750 V Type: H07Z1-K Type 2 Rated voltage: 450/750 V Design standard: HD 21.15 Insulation colours: Brown, Blue and Green/Yellow Cable approvals: Edition: 11/10

ALGERIA Tel: +213 033 75 43 21/22 info@enicab.dz ANGOLA Tel: +244 2 380076/7/8/9/17 condel@snet.co.ao EGYPT Tel.: +202 263 79094 elcairo@generalcable.es FRANCE Tel: +33 (0)1 60 57 30 00 contact@sileccable.com GERMANY Tel: +49 4731 82 0 info@nsw.com ITALY Tel: +39 02 660 49494 rsalvaneschi@generalcable-it.com NORWAY Tel: +47 64 95 59 00 firmapost@generalcable.no PORTUGAL Tel: +351 219 678 500 info@generalcable-pt.com RUSSIA Tel: +7 495 617 00 05 info@generalcable-ru.com SPAIN Tel: +34 93 227 97 00 info@generalcable.es UNITED ARAB EMIRATES Tel: +971 2 6434666 sileccable@sileccable.com UNITED KINGDOM Tel: +44 1604 521 061 gward@generalcable-uk.com Casanova, 150-08036 Barcelona (Spain) www.generalcable.es