REMOTE CONTROLLED BIOETHANOL BURNER USER GUIDE

Similar documents
WARNING! For your safety

SMART BIO ETHANOL ELECTRONIC BURNER

Instruction Manual for Wall Mounted Fireplace, Models: ARC 103A & VAGUE 101A

CHESNEY S. Bio-Ethanol Installation & User Manual. model: EFB1200. Issue 01

CHESNEY S. Bio-Ethanol Installation & User Manual. model: EFB750. Issue 01

CHESNEY S. Bio-Ethanol Installation & User Manual. model: EFB1200 with resevoir. Issue 01

TAB. Ventless Ethanol Fireplace. User s Manual

User s Manual & Safety Instructions Read Carefully Before Use

ATER SS. Ventless Ethanol Fireplace. User s Manual Installation Instructions

LIMA. Ventless Ethanol Fireplace. User s Manual Installation Instructions

LATA. Ventless Ethanol Fireplace. User s Manual Installation Instructions

Instruction manual Safety instructions. Bio-fireplace

Vigo Ventless Tabletop Bio Ethanol Fireplace. User s Manual. Model: GF301801

USER S MANUAL LINCOLN PF Manufactured by: Planika Sp. z o.o. ul. Bydgoska Brzoza Poland

OPERATING INSTRUCTIONS BIO ETHANOL FIREPLACES

Cavo Tabletop Ventless Bio Ethanol Fireplace. User Manual. Model: GF301900BK (BLACK) GF301900W (WHITE)

Braga Free Standing Floor Indoor Outdoor Ethanol Fireplace User s Manual Model: GF202100

Avila Contemporary Indoor Outdoor Ethanol Fireplace. User s Manual. Model: GF201500

USER S MANUAL. WallFire. Manufactured by: Planika Sp. z o.o. ul. Bydgoska Brzoza Poland

USER S MANUAL. Fire Line Automatic 3. Manufactured by Planika Sp. z o.o. ul. Bydgoska Brzoza Poland. I0773#05 of

Computer Controller. The Bio-Burner has user regulated settings as well as built-in safety features to protect you and your burner.

Gas Fire Patio Heater Q9

2 BURNER LP GAS STOVE OPERATING INSTRUCTIONS

Operation & Maintenance Manual

OPERATING INSTRUCTIONS AND SAFETY INFORMATION FOR BIOETHANOL FIREPLACES. models ASOLO TREVISO - VERONA

Model No: Little Devil II (inc ss)

User Manual FLOWMAX-90. for model. Condensing water heater 85,000 BTU. Installation, operating, commissioning and maintenance instructions.

INSTALLATION MANUAL. FLA 2 model E#4 L=1290 FLA 2 model E#4 REMOTE L=1290. Automatic fuel pump

Renovator Range Firebox 900SS

SPECIFICATIONS PART NAME

PartyQ USER S GUIDE Rev. 1.1 for Ver. 1.0 Firmware

USE AND CARE GUIDE WARNING WARNING WARNING WARNING

Operating manual UNIQUE UNIQUE [HAZER]

Renovator Range Firebox XL 1200SS

Cooker Hood LA-72-CAN.

Housing Fact Sheets. Home Fire Protection

2245 Wyecroft Road #5, Oakville, Ontario Canada L6L 5L7 Ph: Toll Free: Fax:

2245 Wyecroft Road #5, Oakville, Ontario Canada L6L 5L7 Ph: Toll Free: Fax:

Alice. In Wall Recessed Electric Fireplace Model Number: (EF172B, EF173B, EF174B, EF175B, EF176B) OWNER S MANUAL

Viper 2.6 Viper deluxe

ELECTRIC FLAT PANEL FIREPLACE HEATER. Model# : BG-36B BG-45B BG-50B BG-60B BG-72B BG-100B OWNER S MANUAL

Standard models feature Burner One. - please refer to specific Model Specification.


Standard models feature Burner One. - please refer to specific Model Specification.

TK Torch Match Lit WARNING: FOR OUTDOOR USE ONLY

Operating manual ORKA & ORKA/CASE. a Look Solutions 1 product

VERNON ELECTRIC FIREPLACE

NO VENTING REQUIRED 120V AC;

FAR INFRARED RAYS HEATER

Flammable and Combustible Liquids Checklist

Important: Read all instructions and warnings carefully before starting installation. INSTALLATION INSTRUCTIONS GENERAL

Operating manual. Viper nt. a Look Solutions 1 product

PARSIFAL INOX PARSIFAL VETRO

Dayton Electric Infrared Fireplace User Manual

installation & operating instructions

ELECTRIC FIREPLACE OWNER S MANUAL

Operating manual. Viper S USA. a Look Solutions 1 product

DIGITAL QUARTZ INFRARED HEATER. Model No.: SPP1500SBH

fire without limitation!

PORTABLE ENGINE HEATER AND EXTERNAL BATTERY CHARGER. Specifications: Benefits: IN: NC:

INFRARED PARAFfIN / KEROSENE / model No: ir20.v2 1. SAFETY INSTRUCTIONS RECOMMENDED FUSE RATING: 5AMP

220V 3200 WATT COMMERCIAL SINGLE INDUCTION COOKTOP OPERATION MANUAL

Owners Manual OWNERS MANUAL. Australia s original Outdoor brand. Part No. Comp827. SAI Global Cert. SAI AS

Gas Fire Patio Heater Lhotse-817

Operating manual. viper nt. a Look Solutions 1 product

USER GUIDE. Hot Water Dispenser. KA-HWD02 Series. Contents ,

for Assembly, Operating & Maintenance of THIS GAS UTILITY STOVE IS DESIGNED FOR OUTDOOR USE ONLY.

ZCR 3824 SAFETY INFORMATION AND OPERATIONS MANUAL

Fire Safety. Fire safety seminars. Fire safety plans

Electric Digital Kettle

Installation and Operation Instructions ELECTRIC FIREPLACE X56WMEF1BLK X56WMEF1WHT

model No: ir20.v2 FUSE

VERNON ELECTRIC FIREPLACE

INFRARED QUARTZ HEATER

INSTALLATION AND OPERATING MANUAL

Good Ideas For Propane Safety

CERT 7795 Fully certified to AS2658:2008. Part No. COMP825 OWNERS MANUAL

INFRARED QUARTZ HEATER

Table Top Patio Heater

OWNER S MANUAL ELECTRIC FIREPLACE INSERT. Model No.: WESTERN (EF42D-45D) WARNING CAUTION

Gas Fire Patio Heater Kongur-500

OWNER S MANUAL. FLAT PANEL FIREPLACE HEATER Model Number: Serena (EF202A) WARNING CAUTION

OWNER S MANUAL KPD-105 DTN11 KPD-140 DVN11 KPD-140 DTN11 KPD-160 DTN11 KPD-52 DVR11

INFRARED PARAFFIN/KEROSENE/ DIESEL HEATER 28/37kW 230V

TECHNICAL INSTRUCTIONS USE AND MAINTENANCE

TecnoAirSystem OPERATING INSTRUCTIONS AND SAFETY INFORMATION FOR BIOETHANOL FIREPLACES. models ASOLO TREVISO - VERONA

Owners Manual OWNERS MANUAL. Australia s original Outdoor brand. Part No. Comp830Li. SAI Global Cert. SAI AS

TOUR-HAZER II Short manual

HAMILTON ELECTRIC STOVE HEATER MODEL EF-BLT01 / EF-BLT04 / EF-BLT07 / EF-BLT08 OPERATION MANUAL

OWNER'S MANUAL WARNING WARNING WARNING WARNING WARNING. Factory No.: HYFP Style No.: WARNING WARNING READ BEFORE USE!

APPUZO RANGE HOOD INSTALLATION

Propane Flame Projector Safety instructions and operating manual

INSTRUCTIONS for installation and use

IDE 20 D / IDE 30 D / IDE 50 D / IDE 60 D / IDE 100 D

Owner s Manual. Middle Static Pressure Duct Type MEU-18MPH2 MEU-24MPH2 MEU-36MPL2 MEU-48MPL2 MIDDLE STATIC PRESSURE DUCT TYPE AIR CONDITIONER

MULTI-SPLIT SYSTEM AIR CONDITIONER / HEAT PUMP. YN-M Series. Inverter++ Models. Two, Three, Four, and Five Zones (Dual, Triple, Quad, and Quint Multi)

Electrical Fireplace Stove with Heater

THC 85N / 175N INDUSTRIAL / COMMERCIAL SPACE HEATER

PVE SERIES POWER VENTER SYSTEM MANUAL

POWER VENTER. Model: PVE Series

Transcription:

REMOTE CONTROLLED BIOETHANOL BURNER USER GUIDE Item Number: BIO332, BIO333, BIO334, BIO335, BIO336, BIO337, BIO338 1. Warning 2. Technical details 3. Preparation before use 4. Power supply connection 5. Filling of the tank 6. Instruction of use 7. Error and function messages 8. Maintenance and cleaning

1. Warning Before any use, the device must be installed accordingly to paragraph 3 & 4. This apparatus is manufactured to have intermittent functioning. Ignoring these instructions could result in death or injury. Use your device only in well-ventilated areas. Always observe the rules for the provision of combustion and ventilating air for unvented heaters. Installing the fireplace horizontally (check it with a spirit level). Fix it strongly against the wall or on the ground. Respect the local and national laws regarding the use of fireplaces. Safety advice Every room where the apparatus is used must be provided with a sufficient fresh supply of oxygen (accordingly to the local rules and regulation). Do not use the device near flammable objects. Never use your device to heat or boil water or as a cooking appliance. It is forbidden to use this device in caravans because of safety reasons. A safety system prevents the ignition when the apparatus is hot. Do not hinder its functioning. Do not move the device when it is lit or cooling down. If the power cable supplied with the fire is damaged, please contact your supplier for a replacement from the manufacturer. Never put your hand, touch or lean on the fireplace when it is functioning or during the cooling period. It is advisable to have a powder or CO2 extinguisher near your fireplace in case of emergencies. Before igniting the fireplace you must be in the same room as the fireplace. Keep the fireplace permanently under surveillance as soon as the fire has started. Keep children away. Never use accessories which are not of origin of stamped by the manufacturer. Never leave any objects on the device. Remove these objects before the ignition. Never use in a room with drafts. Combustible warning Only use denatured Ethanol (Ethyl-Alcohol) 95% vol. minimum. Never use other fuel or combustible. Never store the fuel for the device in your living areas. The addition of another additive (essential oil, perfumes) in the fuel is forbidden. Do not throw anything into the fuel that burns. (cigaret, match, etc.) During the filling, ventilate the room, do not smoke and do not switch on/off your mobile phone. The filling of the tank has to be made when the fire is put out (safety against the fire). An electronic security system prevents the tank door from opening by locking it while the burner is running or is still at high temperature. When the burner is cold, you can press on the trap door switch for refueling. Never dispose the fuel in the water pipelines nor in nature. Respect the environment. Do not store bioethanol near the fireplace.

2. Technical details Item Number Output (Watts) Consumption (Liter/hour) Tank capacity (Liters) Dimensions L x W x H cm Weight (Kgs) Minimum volume* (m 3 ) BIO332 2850 0.4 2.7 50*24*13.5 10.5 42 BIO333 3750 0.6 4.0 66*24*13.5 14 59 BIO334 6200 0.9 5.7 100*24*13.5 20 99 BIO335 7500 1.1 12.4 120*24*21.5 30 120 BIO336 10000 1.56 15.7 150*24*21.5 40 160 BIO337 12400 1.9 19 180*24*21.5 50 197 BIO338 14800 2.2 20.5 200*24*21.5 65 230 *Minimum volume of room advised (m 3 ) Device equipped with an adapter 12 volts-110/240 V AC 50-60 Hz (7A and10a). Device equipped with an infrared remote control (Batteries not supplied). Device equipped with an outside connector (dry contact) allowing a remote switch On/Off. Never start an device which will be unattended afterwards.

3. Preparation before use Remove the packaging of your device. Verify that there is no object in the burner. Remove it if necessary. Devices MUST BE fixed on the ground or built-in. Check that the fireplace has a completely horizontal level using a spirit level. Special precaustions for installation Do not cover the device. Do not put objects on the device while it is burning. Leave a free access to the control buttons. Do not leave curtains or lace curtains within 1 meter of the device. Do not use in a room with draught. Warn people around you, particularly children, of the dangers of fire. Never let them approach the device. 4. Power supply connection An adapter is provided with your device: INPUT 100-240 volts 50/60 Hz and OUTPUT 12V/7A. Before positioning, the device must be connected with the supplied adapter to the power supply. If you want to connect your device to a remote command (home automation, etc.), you must use the dry contact connection. WARNING: This connection is without polarity and electric tension (0 volt) and amperage (0 A). Warning if you use a tension the electric board will be damaged.

5. Filling of the tank To open the door of the tank, press on the left switch near the LCD screen and open the door immediately. (the right one is for ignition) NEVER fill the burner directly. ALWAYS fill the tank from the tank door. Use only the recommended fuel, minimum 95%, delivered in a packaging of safety. Fill the tank carefully without overflowing. Do not smoke near the fireplace. If the burner is too hot, the door will not open (Error message:e2 or E3). Wait until the temperature decrease. Close the bottle and store it away far from the fireplace. Stop the filling once the maximum level is reached: a BIP is emitted by the electronic gauge. If ever some ethanol spills out the reservoir, wipe it completely with a cloth or an absorbing paper before starting the fireplace. Check that no ethanol trace remains outside of the tank door before ignition. You absolutely need to close the tank trap door if you want to ignite your ethanol fireplace. For security reasons, a system will check and lock the trap door before ignition. It is recommended to completely fill the tank on the first use! 6. Instruction of use a) Buttons and LCD display Button 1: Trapdoor Control Button 2: Switch ON/OFF 1 2

b) Ignition Ignite and shut the device only with the switch ON/OFF Button or the remote control or Dry Contact. Leave the remote control out reach of children. Press the Button ON/OFF on the unit for FIVE SECONDS or press on the remote control, the pump will automatically fill up the fireplace. After a few seconds an automatic ignition will take place. If the first ignition is failed, there will be a second one. If the fireplace failed to be lit up, please consult the Error Message on the LED screen and read the paragraph Error Message. Never directly fill up the burner tray. c) Shutting Shut down the device with the switch ON/OFF on the unit or press on the remote control only, The pump will stop. Wait for the flame to stop completely before leaving the room. For security reasons, it is not possible to relit the device just after its extinction. The temperature of the fireplace must have cooled down under 60 o C:140 o F before restarting. Please wait a few minutes.

7. Error and function messages Message Anonaly and functions Solutions Er00 The tank is empty Fill up the tank Er01 The tank is full Stop filling Er02 The temperature of the fireplace (display side) is over 60 o C - 140 o F Wait until the temperature decrease Er03 The temperature of the fireplace (Tank door side) is over 60 o C - 140 o F Wait until the temperature decrease Er04 Failure of ignition (display side) Remove the ethanol from the burner and try again. After 3 attempts contact your retailer Er05 Failure of ignition (tank door side) Remove the ethanol from the burner and try again. After 3 attempts contact your retailer Er06 The trap door of the tank is open Close the trap door of the tank Er07 Er08 Temperature of the device is too high (display side) Temperature of the device is too high (tank door side) Check that there is no flame inside the safety tray. If yes contact your supplier. Chech that there is no flame inside the safety tray. If yes contact your supplier. WARNING: Your device works with automatic safeties, if an error message appears, you can restart the device only if the error has been corrected.

8. Maintenance and cleaning All the operations of cleaning and maintenance must be done with a dead fire and cold device. Clean the burners with a soft rag or cloth. Some components are determining the safety and the functioning of your device. Their replacement may modify the performances of your device. Only original components must be used during the operations of maintenance, or reparations. This maintenance must only be operated by specialists. Failure to observe this operating manual and its operating instructions as well as unauthorized tampering with the device releases us from any liability and also invalidates the warranty covering the devices and accessories. Thank you for reading