INLINE MIXED FLOW FANS IN SOUND INSULATED CASING VENTS TT SILENT M USER MANUAL

Similar documents
CENTRIFUGAL FANS user's manual. model VENTS VK.

INTELLIGENT AXIAL FAN user's manual

INLINE MIXED-FLOW FANS VENTS TT SERIES USER'S MANUAL.

AXIAL FANS USER S MANUAL

AXIAL FANS user's manual. model Quiet

AXIAL DOMESTIC FANS. User manual LARUS LIBELLA FENESO CYCNUS CICONUS SIGILA SIGILA MOTION

Turbo. Service Instructions

Wind. Service instruction

Calm. Service Instructions

AXIAL FAN User s manual. Quiet-dMEV 100 DC.

Aero. Service Instructions

Smart Smart IR. Service instruction SALES DATE MANUFACTURED ON (DATE): APPROVAL MARK SOLD. model (check applicable) is recognized as serviceable

РУКОВОДСТВО USER ПО MANUAL ЭКСПЛУАТАЦИИ CENTRIFUGAL INLINE FANS VKM / VKMZ / VC SERIES

INLINE CENTRIFUGAL FAN. Centro-M OPERATION MANUAL

AXIS-QA G TUBO-M/MZ AXIAL FANS. Axis / Tubo OPERATION MANUAL

OPERATION MANUAL CENTRIFUGAL INLINE FAN WITH ELECTRONICALLY COMMUTATED MOTOR VKM EC SERIES. F88EN-02.indd :07:11

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

USER S MANUAL. VKP Series INLINE FAN

Axial intelligent fan USER S MANUAL

USER'S MANUAL INLINE CENTRIFUGAL FANS IN SOUND-INSULATED CASING VS, VS EC SERIES

Centrifugal inline fans

USER S MANUAL. VCU/VCUN Series CENTRIFUGAL FAN IN SCROLL CASING

USER S MANUAL. Centrifugal inline fan. VKMz 100 Q VKMz 100 VKMz 125 Q VKMz 125. VKMz 250 Q VKMz 250 VKMz 315 Q VKMz 315

USER S MANUAL. Heat Recovery Ventilator. Vents Brig HRV 200 Vents Brig HRV 300

SOUND-INSULATED FAN. Iso-B OPERATION MANUAL

CENTRIFUGAL FAN IN SCROLL CASING. Helix S-Vent OPERATION MANUAL

HEAT RECOVERY VENTILATOR

Turbo Inline Fan, White - Non Illuminated Art no.33500

White - Non Illuminated Art no White - Cool White LED Art no.32600

Inline mixed-flow fans with the air capacity up to 1850 m 3 /h

Inline mixed-flow fans with the air capacity up to 450 m 3 /h

HEAT RECOVERY AIR HANDLING UNIT

CENTRIFUGAL CEILING EXTRACT FAN

USER S MANUAL. Heat (Energy) Recovery Ventilator. Vents Frigate HRV 120 S Vents Frigate ERV 120 S

Air handling unit. BlauAir RH USER S MANUAL

USER'S MANUAL PS

CENTRIFUGAL CEILING EXTRACT FAN

USER'S MANUAL. Single-room reversible energy regeneration ventilator. TwinFresh R-50 TwinFresh RA-50 TwinFresh R-50-2 TwinFresh RA-50-2

SINGLE-ROOM REVERSIBLE UNIT WITH HEAT AND HUMIDITY RECOVERY VENTO V50-1 OPERATION MANUAL

USER S MANUAL DN-2. Drain pump

USER S MANUAL NKP. Duct heater for supply air pre-heating with external control

Issue5 07/13 USERS MANUAL IN-LINE MIXED FLOW

VUT 350 H VUT 500 H VUT 530 H VUT 600 H VUT 1000 H VUT 2000 H HEAT RECOVERY AIR HANDLING UNIT

SINGLE ROOM HEAT RECOVERY AIR HANDLING UNIT

AIR HANDLING UNIT WITH HEAT RECOVERY

HEAT RECOVERY AND HEAT AND HUMIDITY RECOVERY AIR HANDLING UNIT

USER MANUAL. Air handling unit with heat recovery. VUT 300 EVK mini EC VUT 300 EV mini EC VUT 301 EVK mini EC VUT 301 EV mini EC

Offices. Conference halls. Kindergartens Libraries. Restaurants. Schools. Sport halls. Shops

USER S MANUAL UET CONTROL UNIT FOR THE AIR HEATING UNIT WITH ELECTRIC HEATER AOE SERIES

User s Manual RA-3030SS RA-3036SS. NOTE: This unit was designed for indoor residential use and DUCTED operation only.

USER S MANUAL VUT 160 P2B EC A14 VUT 160 PB EC A14 VUT 350 P2B EC A14 VUT 350 PB EC A14 HEAT RECOVERY AIR HANDLING UNIT

USER S MANUAL VUT V(B) EC А14 VUE V(B) EC А14. Heat/heat and humidity recovery air handling unit

Installation manual Mini Comfort 50 S/L 07/ V EN

PH1000T PH1500T PH2000T

User s Manual WALL MOUNT SERIES TABLE OF CONTENTS RA7730SS/RA77B30SS RA7736SS/RA77B36SS RA7742SS/RA77B42SS RA7748SS/RA77B48SS.

User s Manual WS-69TB30 / WS-69TB36 (22 ) WS-69TB42 / WS-69TB48 (22 ) WS-69TS30 / WS-69TS36 (18 ) WS-69TS42 / WS-69TS48 (18 )

USER S MANUAL AiR duct heater with integrated temperature control UNit or A control UNit

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS.

User s Manual ISLAND SERIES TABLE OF CONTENTS RA-7630SS RA-7636SS RA-7642SS RA-7648SS. Table of Contents. Safety Information...

Centrif Duo & Centrif Duo Plus

Store Name: Location: Date Purchased: Serial Number (located on back of unit):

Remote Tower Fan USER INSTRUCTIONS. Product Code: MY146. IMPORTANT Installers and Users please note:

User s Manual. NOTE: This unit does not support ducted operation. For ducted operation, please refer to model WS208L30SS or WS208L36SS

User s Manual WS-62N30SS WS-62N36SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

IN-LINE CENTRIFUGAL FAN VENTS VKP PS 125. User`s manual.

HGW-308R Wall Mountable Micathermic Heater w/ Remote. Model No. HGW-308R Soleus Air International

AH-600 Baseboard Heater

User s Manual WS-4830SS WS-4836SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

IMPORTANT SAFETY INFORMATION:

WALL MOUNT RANGE HOOD. This manual is made with 100 % recycled paper. Electronic version of this manual is available at:

User s Manual WS-63TB36SS WS-63TB42SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

DR-180 Through the Wall Exhaust Fan PRODUCT MANUAL & INSTALLATION GUIDE

Lo-Carbon Quadra Centrifugal Fan

"Microbox" DC Models MBOX 125/2DC MBOX 125/2DC204

Instructions for use PHPC 6.4F AM X

Series VENTS VUT R WH ЕС

READ AND SAVE THESE INSTRUCTIONS GENERAL SAFETY INFORMATION

USER MANUAL. Frigate HRV 120 SR Frigate ERV 120 SR. Heat (energy) recovery ventilation unit

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

BASEBOARD MICATHERMIC HEATER

INSTALLATION AND USER S MANUAL COOKER HOOD RS-600/A-S

MV 2. Operating Instructions. Before first use of the unit read these operating instructions and act in accordance with them.

Model No. CZ2011O Oak Finish CZ2011C Cherry Finish CZ2011W Walnut Finish CZ2011B Black Finish DIGITAL QUARTZ INFRARED HEATER OWNER S MANUAL

General safety precautions English

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

Table of Contents. Safety Information Content Checklist Measurements Preparation Installation

ISLAND MOUNT RANGE HOOD. This manual is made with 100 % recycled paper. Electronic version of this manual is available at:

USER'S MANUAL. Micra 150 HEAT RECOVERY UNIT

ISLAND MOUNT RANGE HOOD. This manual is made with 100 % recycled paper. Electronic version of this manual is available at:

Lo-Carbon SELV Tempra

User s Manual WS-3230SS WS-3236SS WS-3242SS WS-3248SS

KKKKKKKCOOKER HOOD INSTRUCTION MANUAL

IMPORTANT INSTRUCTIONS READ & SAVE

Classic Electric Stove

EH1210. airooncentre.co.uk. Peltier Dehumidifier Déshumidificateur Peltier. The Award Winning Ventilation Specialists

Cooker Hood LA-72-CAN.

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

DIGITAL QUARTZ INFRARED HEATER. Model No.: SPP1500SBH

Low Profile. Baseboard Heater

Transcription:

IIE MIED FOW FAS I SOUD ISUATED CASIG VETS TT SIET M USER MAUA www.ventilation-system.com 2013

! WARIG Disconnect the fan from power mains prior to any connection, servicing and repair operations. Mounting and maintenance are allowed for duly qualified electricians with valid electrical work permit for electric operations at the units up to 1000 V after careful study of the present user's manual. The single phase power mains must comply with the acting local electrical norms and standards. The fixed electrical wiring must be equipped with an automatic circuit breaker. The fan must be connected to power mains through an automatic circuit breaker integrated into the fixed wiring system with the gap between the breaker contacts on all poles not less than 3 mm. Check the fan for any visible damages of the impeller and the casing before starting installation. The casing internals must be free of any foreign objects which can damage the impeller blades. Misuse of the device or any unauthorized modification is not allowed. The fan is not to be used by children and persons with reduced physical, mental or sensory capacities, without proper practical experience or expertise, unless they are controlled or instructed on the product operation by the person(s) responsible for their safety. Do not leave children unattended and do not let them play with the product. Take steps to prevent ingress of smoke, carbon monoxide and other combustion products into the room through open chimney flues or other fire protection devices. Sufficient air supply must be provided for proper combustion and exhaust of gases through the chimney of fuel burning equipment to prevent back drafting. Transported medium must not contain any dust or other solid impurities, sticky substances or fibrous materials. Do not use the fan in the environment containing hazardous or explosive materials and vapours, i.e. spirits, gasoline, insecticides, etc. Do not close or block the fan intake or extract vents in order to ensure the most effective air passage. Do not sit on the fan and do not put objects on the fan. Fulfil the requirements stated in this user's manual to ensure long service life of the product. Recycle at the end of the service life. Do not dispose the product with unsorted municipal trash. 2

Read the present user's manual carefully before proceeding with installation works. Compliance with the manual requirements ensures reliable operation and long service life of the product. Keep the user's manual available as long as you use the product. You may need to re read the information on the product servicing.! WARIG DEIVERY SET The delivery set includes: 1. Fan 1 item; 2. Screws and dowels 4 items; 3. Plastic screwdriver (only for modifications with timer) 1 items; 4. User's manual; 5. Packing box. SHORT DESCRPTIO The product described herein is a mixed flow inline fan for supply or extract ventilation of premises heated during winter time. The fan is rated for connection to 100, 125, 150, 160, 200, 250 and 315 mm. The fan is equipped with a two speed motor. VETS TT Silent M basic model; VETS TT Silent M V model with a built in speed switch; VETS TT Silent M RV model with a built in speed switch, power cable and plug, fig. 40; VETS TT Silent M T model with a turn off delay timer adjusted from 2 to 30 minutes, fig. 39; VETS TT Silent M U(U1) model with a speed controller with an electronic thermostat, a built in temperature sensor and a power cable with a plug, fig. 41; VETS TT Silent M Un (U1n) model with a speed controller with an electronic thermostat, an external temperature sensor fixed on 4 m cable and a power cable with a plug, fig. 41; VETS TT Silent M P model with a speed controller and a power cable with a plug, fig. 42. fan size (100, 125, 150, 160, 200, 250 or 315 mm). Due to constant improvements the design of some models may slightly differ from those ones described in this manual. OPERATIO RUES The fan is designed for connection to AC 220 to 240 V, 50/60 Hz power mains. The fan is designed for continuous operation always connected to power mains. Air motion direction in the system must match the pointer on the fan casing. Ingress protection rating against access to hazardous parts and water ingress IP4. The fan is rated for operation at the ambient temperature ranging from +1 C up to +45 C. The transported air temperature must not exceed +60 C. The fan is rated class II electrical appliance. 3

EECTROICS COTRO OGIC The fan TT Silent M T is turned into operation after control voltage is supplied by the external switch (e.g., by the light switch) to the input terminal T. After the control voltage is off the fan continues to operate within the timer period set by the timer from 2 to 30 minutes. To adjust the turn off delay time rotate the potentiometer control knob T clockwise to increase and counter clockwise to decrease the off delay time respectively (fig. 39). WARIG! The timer circuit is under mains voltage. Cut power supply to the fan off prior to any adjustments with the timer. The fan delivery set includes a specially designed plastic screwdriver for fan settings adjustments. Use the screwdriver to change the turn off delay time. Do not use a metal screwdriver, knife, etc. for adjustment operations not to damage the circuit board. The fan model TT Silent M U(U1) is equipped with electronic TSC module (speed controller with electronic thermostat) for automatic fan speed (air flow) control depending on air temperature (fig. 41). 2 control knobs on the electrical compartment cover are used: for setting the motor speed; for setting the thermostat set point. The ED light of the thermostat is placed on the fan cover. The fan has a temperature and timer dependent operating logic: temperature dependent control logic (TT Silent M U): to maintain air temperature with accuracy to within 2 C. The fan changes its speed rarely. As air temperature rises up to the set point, the fan switches to high speed. As air temperature drops down 2 C below the set point or if the initial temperature is below the set temperature point, the fan operates at low set speed from the start. timer dependent control logic (TT Silent M U1): to maintain air temperature with high accuracy. The fan changes its speed more often as compared to the previous control logic, but the minimum operating time at one speed is not less than 5 minutes. As air temperature rises up to the set point, the fan switches to maximum speed. Synchronously, the speed switch delay timer is activated for 5 minutes. As air temperature drops down below the set point, but only after 5 minutes countdown after switching to high speed, the fan switches to lower set speed. If the initial temperature is below the set temperature point, the fan operates at low set speed from the start. 4

The fan TT Silent M P (fig. 50) is equipped with a speed controller that enables switching the fan on/off, smooth speed (air flow) control from minimum to maximum value. MOUTIG The fan is suitable for top and vertical installation on the floor, on the wall or on the ceiling (fig. 2). While mounting the fan provide extra protection against water ingress, such as: 1. For the top mounting: install an outer protecting hood above (fig. 3). 2. For any mounting position: connect an air duct on both sides of the fan (fig. 3). Mounting sequence for various fan models are shown in fig. 4 8 and 21 38. Wiring diagrams for various fan models are shown in fig. 9 20. Terminal designations: 1 low speed terminal; 2 high speed terminal; automatic circuit breaker; S external speed switch; S1 external switch (e.g., light switch); input terminal. Designation of the automatic circuit breaker on wiring diagram Designation of the external switch on wiring diagram Automatic circuit breaker S External on/off switch/speed switch S/ST 1 MAITEACE Clean the product surfaces regularly (once in 6 months) from dust and dirt (fig. 43 46). Disconnect the fan from power mains prior to any maintenance operations. To clean the fan use a soft cloth and a brush wetted in a mild detergent solution. Avoid water dripping on the electric components (fig. 60). Wipe the surfaces dry after cleaning. STORAGE AD TRASPORTATIO RUES Transportation is allowed with any vehicle provided that the product is protected against mechanical and weather damage. Store the delivered product in the manufacturer's original packing box in a dry ventilated premise with the temperature range from +5 C up to + 40 C and relative humidity less than 80%. The storage environment must not contain dust, acid or alkali vapours that may cause corrosion of the product parts. 5

WARRATY The fan is manufactured at the factory of "Ventilation systems" PrJSC (hereinafter referred to as the Manufacturer). By purchasing this product the customer confirms to have read and agreed to the terms, rules and requirements related to operation, storage, transportation, mounting, adjustment, connection, maintenance and repair as well as warranty obligations with respect to this product as set forth in the manufacturer's accompanying documentation to the product. The manufacturing company sets forth the warranty period (service life) of the product as 24 months following the sale date via retail network subject to the customer's ensuring compliance with the rules of transportation, storage, mounting and operation of the product. In case of any malfunction of the product through the fault of the Manufacturing company within the warranty period (service life), the customer shall have the right to elimination of the manufacturing defects by means of warranty servicing performed free of charge. The warranty servicing implies performance of activities related to elimination of defects in the product aimed to provide intended use of the product by the customer. The defects are eliminated either by replacing or repairing such a product or a part (component) thereof. ATTETIO! With the purpose of performing warranty servicing you please produce User Manual or other relevant substituting document and the payment document as an evidence of the purchase with indication of the sale date. The product model shall comply with that one specified in the User Manual or other relevant substituting document. With the purpose of performing warranty servicing please contact the trade company where you purchased the product. If warranty servicing on the spot proves impossible, you will be provided with the necessary information regarding rendering of this service. Manufacturer's warranty shall not be applied in the following cases: in case the customer fails to provide the product in complete according to the package contents specified in the User Manual or other relevant substituting document, including any components disassembled by the customer; in case of incompliance of the model or marking of the product with data specified on the product packaging and in the User Manual or other relevant substituting document; in case of non timely technical maintenance of the product by the customer (dust, mud, oil condensate, foreign particles); in case of causing external damage to the product by the customer ('damage' shall not apply to external changes of the product required for the product mounting); in case of altering the product design or further reworking of the product; in case of replacing and using parts, units and components of the product not prescribed by the manufacturing company; in case of the product misuse; in case of the customer's violating product operation rules; in case of connecting the product to electric mains of voltage exceeding voltage value specified in the User Manual; in case of step voltage that resulted in the product failure; in case of the customer's performing unauthorised repair of the product; in case of performing repair of the product by third persons unauthorized by the manufacturing company; in case of warranty period (service life) expiry; 6

in case of the customer's violating transportation rules assuring prevention of damaging and/or destruction of the product; in case of the customer's violating product storage rules; in case of performing unlawful actions by third persons with respect to the product; in case of force majeure (fire, flood, earthquake, war, hostilities of any kind, blockade); in case of absent seals, provided such seals are prescribed by the User Manual or other relevant substituting document; in case of unavailable warranty card; in case of unavailable payment document to confirm the purchase with indication of the sale date. The manufacturing company shall be responsible for defects arising through its fault prior to the moment of transferring the product to the ownership of the customer. The manufacturing company shall not be responsible for defects arising after transferring the product to the customer and caused by the customer's violating the rules of transportation, storage, assembly and operation of the product, or by actions of third persons, an accident or force majeure circumstances. The manufacturing company shall not be responsible for damage to health and property of the customer caused by the customer's violating the User Manual or other relevant substituting document; other use of the product by the customer other than its intended use, or by failure of the customer to comply with warnings and other information on the product specified in the User Manual or other relevant substituting document, or by the customer's violating the rules of transportation, storage, mounting, maintenance and operation of the product. 7

2 3 8

ТТ Silent-М 100/125/150/160/200/250/315 4 5 5 6 7 8 9

ТТ Silent-М 100/125 10 MA 1 MA / MI 1 2 16 11 2 9 2 1 S MI 12 ТТ Silent-М 150/160/200/250/315 2 14 MA 15 10 MI MA / MI 1 2 13 1 S 16 1 2

ТТ Silent-М 100/125/150/160/200/250/315 Т ST T ST T 2 17 MA terminal block for 4 contacts terminal block for 5 contacts ST T S 2 1 ST T S 1 terminal block for 4 contacts terminal block for 5 contacts 18 MA / MI ST T ST 1 19 MI T 1 terminal block for 5 contacts terminal block for 4 contacts 2 1 20 11

ТТ Silent-М 100/125 12 21 22 23 24 25 26

ТТ Silent-М 150 27 28 29 30 31 32 13

ТТ Silent-М 160/200/250/315 14 33 34 35 36 37 38

- Х + 2 min 30 min 39 MI STOP MA 40 15

thermostat control knob speed control knob 41 speed control knob 42 16

ТТ Silent-М 100/125/150/160/200/250/315 43 44 45 46 17

18

The fan is duly recognized as serviceable ACCEPTACE CERTIFICATE Approval mark ÒÒ Silent-Ì 100 ÒÒ Silent-Ì 125 V ÒÒ Silent-Ì 150 RV ÒÒ Silent-Ì 160 T ÒÒ Silent-Ì 200 U ÒÒ Silent-Ì 250 P Manufactured on (date): 1 ÒÒ Silent-Ì 315 n Sold (name and stamp of the trade company) Date of sale (mark the proper model) www.ventilation-system.com V97E-02