ExDetector HC-100. Data Sheet. Gas Measuring and Alarm Systems

Similar documents
SENSOR O2 O2-A

ExDetector IRCO2. ExDetector IRHC. Operating and Installation Instructions. Gas Detection and Warning Systems

SERIES 47K GAS SENSOR

Technical Data. Dimensions

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. Dimensions

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Dräger X-am 7000 Multi-Gas Detection

Technical Data. General specifications Switching element function Rated operating distance s n 8 mm

Inductive slot sensor

SITRANS T. SITRANS T Explosion protected temperature sensor. General information. Marking of the degree of protection. Range of uses.

VQ500 Series Combustible Gas Detector Elements

Technical Data. General specifications. Rated operating distance s n 5 mm

Technical Data. Dimensions

SIMRAD GD10 IR GAS DETECTOR

MICROpeL 75 Combustible Gas Sensor Part Number: PM

EC24. Operation Manual. (Type MWG 2411, MWG 2412, MWG 2413 and MWG 2414)

OLC(T) 100 FIXED GAS DETECTOR

SIMRAD GD10PE IR GAS DETECTOR

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Aluminium or Stainless Steel version

SIMRAD GD10P - IR GAS DETECTOR OPERATING MANUAL

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Ex Long & Short stroke LPI POSITION TRANSMITTER MKII For linear position measurement in compressors

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Certifications. The Fixed Gas Detection People

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Technical Data. Dimensions

Dräger X-am 5000 Multi-Gas Detection

Dräger X-am 5000 Multi-Gas Detection

Flammable gases Detectors. Model DAX 03F DAX 03F- C DAX 03F- H. Note for installation, use and maintenance. Version 1.2

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

Transmitters/Sensors. OLCT Series

Dräger Polytron 8310 IR Detection of flammable gases and vapour

Physikalisch-Technische Bundesanstalt

GAS DETECTOR ST400EC PART.NO

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

Dräger PIR 3000 Detection of flammable gases and vapours

Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device

User Manual. GPD 3000 e. gas detector

3M Oldham OLCT 100. Description. Fixed Gas Detector

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

Dräger X-am 2500 Multi-Gas Detection

ALTAIR 5X Multigas Detector Product Specification

PEPPERL+FUCHS GmbH

GTF 103-Ex. GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26. Temperature Probe for potentially explosive atmospheres

Gas leak detectors. For a quick overview. testo testo testo testo gas detector testo 316-Ex

Dräger Pac Ex 2. Elegant and smart... Explosive hazards and lack or surplus of oxygen under control

4P75 CiTipeL Combustible Gas Sensor Part Number: PM

IR1xxx Series 1, IR2xxx Series 1 Miniature Infrared Gas Sensors for Hazardous Areas and Intrinsic Safety in Mining

Dräger Polytron 8000 Stationary gas detector (EC)

3years. Detection of explosive gases, toxic gases and oxygen. Infrared XP IR version. SIL 2 high reliability IP 66.

CO warning instruments and gas spillage detectors

Dräger X-am 7000 Multi-Gas Detection

EU DECLARATION OF CONFORMITY

ATEX Installation Instructions for Micro Motion F-Series Sensors with Certificate DMT 01 ATEX E 158 X

VERSAFLOW VORTEX Supplementary instructions

Advance Optima Continuous Gas Analyzers AO2060-Caldos15, -Caldos17, -Magnos106, -Uras14 Category 2G Analyzer Modules

IRceL CH4 Methane (CH 4

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Gas leak detectors. For a quick overview. testo testo testo testo gas detector testo 316-Ex.

Dräger Polytron 8700 IR Detection of flammable gases and vapors

SENSE Instruments CO., LTD. Data sheet Gas detector Page 1 / 5. Gas detector

We measure it. testo 316-Ex CH 4 testo 316-1

Dräger X-am Dräger X-am 7000: Modular, rugged and waterproof.

Transmitter PEX 3000 Instructions for Use

Dräger Polytron 8200 Stationary gas detector (CatEx)

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Dräger Polytron 8310 Stationary gas detector (DSIR)

FLAMMABLE GAS DETECTOR DAX 3F-C INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS. DAX3FC_MAN01_EN.indd Ver. V1R2

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

Sensepoint. Fit For Purpose Flammable, toxic and oxygen versions available High performance, low cost Suitable for new and retro fit applications

OLCT 100 DETECTION DE GAZ FIXE. Certifications. Better detection. Better protection. Detection of Combustible, Toxic or Oxygen gases

Hygro/hygrothermal transducers (hygrometric)

GMA200-MT. Operation Manual. Gas detection controller for mounting rail assembly

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

OPTIBAR P 1010/2010 C Supplementary instructions

Process Control PIP PCEA001 Fixed Gas Detection Guidelines

4P-90 CiTipeL Combustible Gas Sensor Part Number: PM

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

OPTIWAVE X500 Supplementary Instructions

testo 316-EX gas leak detector Instruction manual

Dräger PEX 3000 Flammable Gas Detection

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

ATEX GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres. Directive 94/9/EC

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

Manual Power relay SR853

SAFETY MANUAL. Intelligent Sensors for H 2 S Gas Applications

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

IECEx Certificate of Conformity

Sensepoint. Fit For Purpose Flammable, toxic and Oxygen versions available High performance, low cost Suitable for new and retro fit applications

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

compact detector Detection of more than 200 flammable and toxic gases iso 9001:2008

STAINLESS STEEL FLAMMABLE GAS DETECTOR DAX 3F-I INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS. DAX3FI_MAN01_EN Ver. V1R2

Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS

Dräger X-am 2500 Multi-Gas Detector

NZQA registered unit standard version 1 Page 1 of 5. Install fixed gas detection apparatus in hazardous areas

4) Intrinsic Safety Certification

Transcription:

HC-100 Gas Measuring and Alarm Systems

HC-100 Application / Construction The HC100 series of measuring probes, used in conjunction with evaluation systems, have the following functions: Measurement and indication of the actual concentration of potentially explosive gases and vapours Monitoring and warning of these gases Triggering of safety measures - Technical: the rise in concentration is counteracted by control actions (fans, disconnections, etc.) - Organisational: visual and audible signals. Detector Controler A gas warning system consists of the following components: probe evaluation system controllable devices such as fans, warning screens and solenoid valves Product features detection of combustible gases and vapours measuring range: 0-100 % LEL measuring principle: catalytic combustion linear measuring signal 4-20 ma one-man calibration (optional operating unit) ATEX-conformity for applications in hazardous areas zone 1 and 2 3-wire technology - 24 V DC - 4-20 ma - ground types: - HC100-M: standard for wall mounting - HC100-T / HC100-K: with separate transmitter for mounting in ventilation ducts Page 2

HC-100 Operating principle The probe electronics control the operating parameters (heater voltage) of the sensor. The sensor consists of an active and an inactive element. The inactive sensor element is connected in a Wheatstone bridge circuit with the active element and compensates for environmental effects such as variations in ambient temperature. As soon as combustible gas reaches the active sensor, the sample gas is burned. The heat produced in the reaction changes the electrical resistance value and hence the bridge signal. These small voltage signals are processed and then converted to a 4-20 ma measurement signal. Operating parameters are programmed and the measuring element adjusted using the operating unit, which is also explosion protected, available as an option. This facilitates operation and maintenance, even in the hazardous area. Block diagram "Ex e" "Ex d" DC 1 Uh=const "Ex e" "Ex d" DC 2 U 4-20mA CPU # 3 # Interface U "Ex i" Technical data (gases) Areas of use Device category HC100- M HC 100-T HC 100-K Zone 1 and 2 hazardous areas Application Wall-mounting Duct-mounting Detectable gases Range Measurement principle Response time T90 Warm-up time Max. flow velocity Combustible gases and vapours 1) List of the examined gases / vapours see EC-Type-Examination BAM 03 ATEX 0003X 0-100 % LEL in air Oxygen in measuring gas 10... 20,9 vol% Catalytic combustion Dependent on sample gas (10... 60 sec) 10 sec 15 m/sec (BAM examined to 6 m/sec) Temperature range -20 C to +55 C HC 100-T: -20 C to +55 C Atmospheric pressure range Humidity range 800-1100 hpa 20-90 % rh HC 100-K: Housing: -20 C to +55 C Sensor: -20 C to +80 C Storage terms Temperature: -25 C to 60 C Pressure: 800 hpa to 1100 hpa Humidity: 20% r.f. to 90% rh 1) The service life of a catalytic combustion sensor is affected by so-called catalyst poisons. These poisonous substances include compounds of sulphur, phosphorus, silicon and lead. The anticipated service life of > 3 years is also reduced by corrosive substances which release fluorine and chlorine compounds in the course of the reaction at the measuring element. Page 3

HC-100 Technical data (installation) Field interface HC100-M HC 100-T HC 100-K 4-20 ma, max load 350 Ohm Supply voltage (probe terminal) Calibration interface Safety maximum voltage 18-32 V DC SELV / PELV max 5.5 W pre-fuse 100 ma antisurge HC 100-T: 18-32 V DC SELV / PELV max 5.5 W pre-fuse 100 ma antisurge HC 100-K: only for connection to the specified interface of the HC 100-T Pmax-= 1.6 W Umax = 12 V DC Imax = 0.5 A DC Ignition protection type Ex ib IIC; only for connection to a certified intrinsically safe circuit: Ui = 13.8 V / Pi = 432 mw / Li = 0 / Ci = 0 Um = 250 V Max. cable length 1000 m depending on the cable type 1000 m depending on the cable type Connecting cablel Suitable evaluation instruments EC-Type-Examination Directive 94/9/EC electrical safety 3 active cores, cable screened preferably H05VVC4V5-K Gasmesscomputer 8022, GMC 8022E, GMC 8364, GMC 8420 Housing/electronics: Ex de [ib] IIC T6-20 C < TA < +55 C Measuring head: Ex e IIC T4 für -20 C < TA < 80 C T6 für -20 C < TA < 55 C PTB 00 ATEX 1076U Connecting lead HC 100-T / HC 100-K: 3 m / 1.5 mm² / screened HC 100-T: Housing/electronics: Ex de [ib] IIC T6-20 C < TA < +55 C HC 100-K: Housing: Ex de IIC T6-20 C < TA < +55 C Mechanical data Protection (housing) IP54 HC 100-M HC 100-T HC 100-K Housing material Weight Sensor: stainless steel Housing: aluminium approx. 1300 g HC 100-T: approx. 1200 HC 100-K: approx. 1500 g g Cable entry Cable diameters 8-13 mm Terminals 3-way 0.5-1.5 mm2 Page 4

HC-100 Mechanical data HC 100-M 85 mm 170 mm 110 mm HC 100-T 85 mm 160 mm 110 mm HC 100-K 75 mm 90 mm 230 mm 345 mm Flange d=11 mm d=30 mm 75 mm 105 mm Page 5

HC-100 Certification EC-Type-Examination Directive 94/9/EC - Housing/electronics ( HC 100-M / -T): Ex de [ib] IIC T6 - Housing ( HC 100-K): Ex de IIC T6 - Sensor: / Ex d IIC T4 for -20 C < TA < +80 C T6 for -20 C < TA < +55 C PTB 00 ATEX 1076U Performance certification: BAM 02 ATEX 0003 X Instrument safety For authorised use of the HC100 in Zone 1 and 2 hazardous areas, compliance with the following standard ensures the highest instrument safety: EN 50270 (product standard) Electromagnetic compatibility of electrical apparatus for the detection and measurement of combustible gases, toxic gases or oxygen Accessories test gas set calibration gases operating unit type Calibrationbox-I Service Everything from one single source - from design to installation of your new gas warning system. This is guaranteed by our comprehensive sales and service network. Please ask about the personal contact for your region. Our service technicians are also available for after-sales support and advice. Bieler + Lang GmbH Gas Detection and Warning Systems Postfach 1129, D-77842 Achern Von-Drais-Str. 31, D-77855 Achern Telephone +49 (0) 78 41 / 69 37-0 Telefax +49 (0) 78 41 / 69 37-99 E-Mail info@bieler-lang.de Internet www.bieler-lang.de Technical status: 04/2014 Technical modifications possible! Page 6