M-SERIES SUBMITTAL DATA: MSZ-FH0NA & MUZ-FH0NA,000 BTU/H WALL-MOUNTED HEAT PUMP SYSTEM Job Name: System Reference: Date: Electrical Power Requirements 08 / 30V, -Phase, 0 Hz ACCESSORIES: Unit Unit: MSZ-FH0NA Wireless Remote Controller : MUZ-FH0NA Condensate Pump (BlueDiamond X87-7/7; 5/30V) Condensate Pump (Sauermann SI30-5/30; 5/30V) Replacement Platinum Deodorizing Filter (MAC-3000FT-E) Replacement Anti-allergy Enzyme Filter (MAC-330FT-E) Air Discharge Guide (MAC-889SG) Base Pan Heater (MAC-0BH-U) Drain Socket (MAC-80DS) Controls Wireless Controller (MHK) Wired Remote Controller PAR-3MAA (Requires MAC-333IF-E) Wireless Interface for kumo cloud (PAC-WHS0WF-E) Thermostat Interface (PAC-USCN-) SPECIFICATIONS: Rated Conditions (Capacity / Input) Btu/h / W,000 / 35 at 7º F Btu/h / W 8,700 / 55 Capacity Range Minimum Maximum Btu/h,700 9,000 at 7º F Btu/h,00,000 at 7º F 3 Btu/h - 0,700 at 5º F Btu/h - 8,700 : 80º F(7º C)DB / 7º F(9º C)WB; Outdoor: 95º F(35º C)DB / 75º F(º C)WB * at 7ºF : 70º F (º C)DB / 0º F (º C)WB; Outdoor: 7º F (8º C)DB / 3º F (º C)WB * 3 at 7º F : 70º F(º C)DB / 0º F(º C)WB; Outdoor: 7º F(-8º C)DB / 5º F(-9º C)WB * at 5º F : 70º F (º C)DB / 0º F(º C)WB; Outdoor: 5º F(-5º C) DB / 5º F(-5º C)WB * Rating Conditions per AHRI Standard: Operating Conditons ( Intake Air Temp.) (Max./ Min.) 90º F (3º C) DB / 7º F (9º C) DB 80º F (7º C) DB / 70º F (º C) DB Operating Conditons (Outdoor Intake Air Temp.) (Max./ Min.) 5º F (º C) DB / º F (-0º C) DB 75º F (º C) DB / -3º F (-5º C) DB** 5 Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. ** System cuts out at -8º F (-8º C) to avoid thermistor error and automatically restarts at -º F (-º C). AHRI Efficiency Ratings SEER / HSPF 33. / 3.5 COP at 7 o F / 7 o F.8 / 3. Energy Star Yes ENERGY STAR products are third-party certified by an EPA-recognized Certification Body. Minimum Circuit Ampacity (MCA) / Outdoor A / Unit Blower Motor (ECM) F.L.A. 0.7 Blower Motor Output W 30 SHF / Moisture Removal 0.9 / 0. pt./h Field Drainpipe Size O.D. 5/8 (5) Compressor Fan Motor (ECM) F.L.A. 0.50 Airflow Rate (Lo - Med - Hi - Super Hi - Powerful) () () DRY CFM DC INVERTER-driven Twin Rotary 37-7--30-38 WET 7-3-90--38 DRY 0-7-5-35-37 Outdoor,50 /,80 Sound Pressure Level (Lo - Med - Hi - Super Hi - Powerful) Outdoor External Dimensions (H x W x D) Outdoor (H x W x D) Net Weight db(a) 7 0-3-9-3-0 0--9-3- 8 Lbs.(kg) + / x 3-7/ x 9-3/ (305 +7 x 95 x 3) -5/8 x 3-/ x -/ (550 x 800 x 85) 9 () Outdoor 8 (37) External Finish Munsell.0Y 9. / 0. Outdoor Munsell No. 3Y 7.8 /. Refrigerant Refrigerant Piping (Flared) Liquid (High Pressure) R0A; lb. 9 oz. / (.35) Gas (Low Pressure) 3/8 (9.5) Pipe Length (Height Diff.) Pipe Length (Length.) Ft. (m) 0 () 5 (0) 0 Mitsubishi Electric US, Inc.
DIMENSIONS: MSZ-FH0NA & MUZ-FH0NA MSZ-FH0NA MSZ-FH09NA MSZ-FHNA MSZ-FH5NA MSZ-FH8NA MSZ-FH8NA MSZ-FH0NA MSZ-FH0NA MSZ-FH09NA MSZ-FHNA MSZ-FH5NA MSZ-FH8NA MSZ-FH8NA (MSZ-FH0/09/NA) (MSZ-FH5/8NA/8NA) (MSZ-FH0/09/NA) (MSZ-FH5/8NA/8NA) MUZ-FH0NA MUZ-FH0NAH MUZ-FH09NA MUZ-FH09NAH MUZ-FHNA MUZ-FHNAH MUZ-FH0NA REQUIRED SPACE * in. (00 mm) when front and sides of the unit are clear in. (00 mm) clear * in. (00 mm) (MUZ-FH0/09/NA) (MUZ-FH0/09/NAH) 8 in. (00 mm) * in. (350 mm) * When any sides of left, right and rear of the unit are clear x hole 3/8 x 3/ Liquid refrigerant pipe joint Refrigerant pipe (flared) Ø / Gas refrigerant pipe joint Refrigerant pipe (flared) Ø 3/8 OBH83D OBH83D 30 Satellite Boulevard. Suwanee, GA 300 Toll Free: 800-33-8 www.mehvac.com FORM# MSZ-FH0NA ~ MUZ-FH0NA - 003 0 Mitsubishi Electric US, Inc.
M-SERIES SUBMITTAL DATA: MSZ-FH09NA & MUZ-FH09NA- 9,000 BTU/H WALL-MOUNTED HEAT PUMP SYSTEM Job Name: System Reference: Date: Electrical Power Requirements 08 / 30V, -Phase, 0 Hz ACCESSORIES: Unit Unit: MSZ-FH09NA Wireless Remote Controller Condensate Pump (BlueDiamond X87-7/7; 5/30V) Condensate Pump (Sauermann SI30-5/30; 5/30V) Replacement Platinum Deodorizing Filter (MAC-3000FT-E) Replacement Anti-allergy Enzyme Filter (MAC-330FT-E) Air Discharge Guide (MAC-889SG) Base Pan Heater (MAC-0BH-U) Drain Socket (MAC-80DS) Controls : MUZ-FH09NA- Wireless Controller (MHK) Wired Remote Controller PAR-3MAA (Requires MAC-333IF-E) Wireless Interface for kumo cloud (PAC-WHS0WF-E) Thermostat Interface (PAC-USCN-) SPECIFICATIONS: Rated Conditions (Capacity / Input) Btu/h / W 9,000 / 50 at 7º F Btu/h / W 0,900 / 70 Capacity Range Minimum Maximum Btu/h,700,000 at 7º F Btu/h,00 8,000 at 7º F 3 Btu/h -,00 at 5º F Btu/h - 0,900 : 80º F(7º C)DB / 7º F(9º C)WB; Outdoor: 95º F(35º C)DB / 75º F(º C)WB * at 7ºF : 70º F (º C)DB / 0º F (º C)WB; Outdoor: 7º F (8º C)DB / 3º F (º C)WB * 3 at 7º F : 70º F(º C)DB / 0º F(º C)WB; Outdoor: 7º F(-8º C)DB / 5º F(-9º C)WB * at 5º F : 70º F (º C)DB / 0º F(º C)WB; Outdoor: 5º F(-5º C) DB / 5º F(-5º C)WB * Rating Conditions per AHRI Standard: Operating Conditons ( Intake Air Temp.) (Max./ Min.) 90º F (3º C) DB / 7º F (9º C) DB 80º F (7º C) DB / 70º F (º C) DB Operating Conditons (Outdoor Intake Air Temp.) (Max./ Min.) 5º F (º C) DB / º F (-0º C) DB 75º F (º C) DB / -3º F (-5º C) DB** 5 Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. ** System cuts out at -8º F (-8º C) to avoid thermistor error and automatically restarts at -º F (-º C). AHRI Efficiency Ratings SEER / HSPF 30.5 / 3.5 COP at 7 o F / 7 o F.5 / 3.33 Energy Star Yes ENERGY STAR products are third-party certified by an EPA-recognized Certification Body. Minimum Circuit Ampacity (MCA) / Outdoor A / Unit Blower Motor (ECM) F.L.A. 0.7 Blower Motor Output W 30 SHF / Moisture Removal 0.9 / 0. pt./h Field Drainpipe Size O.D. 5/8 (5) Compressor Fan Motor (ECM) F.L.A. 0.50 Airflow Rate (Lo - Med - Hi - Super Hi - Powerful) () () DRY CFM DC INVERTER-driven Twin Rotary 37-7--30-38 WET 7-3-90--38 DRY 0-7-5-35-37 Outdoor,50 /,80 Sound Pressure Level (Lo - Med - Hi - Super Hi - Powerful) Outdoor External Dimensions (H x W x D) Outdoor (H x W x D) Net Weight db(a) 8 0-3-9-3-0 0--9-3- 9 Lbs.(kg) + / x 3-7/ x 9-3/ (305 +7 x 95 x 3) -5/8 x 3-/ x -/ (550 x 800 x 85) 9 () Outdoor 8 (37) External Finish Munsell.0Y 9. / 0. Outdoor Munsell No. 3Y 7.8 /. Refrigerant Refrigerant Piping (Flared) Liquid (High Pressure) R0A; lb. 9 oz. / (.35) Gas (Low Pressure) 3/8 (9.5) Pipe Length (Height Diff.) Pipe Length (Length.) Ft. (m) 0 () 5 (0) 0 Mitsubishi Electric US, Inc.
DIMENSIONS: MSZ-FH09NA & MUZ-FH09NA- MSZ-FH0NA MSZ-FH09NA MSZ-FHNA MSZ-FH5NA MSZ-FH8NA MSZ-FH8NA MSZ-FH09NA MSZ-FH0NA MSZ-FH09NA MSZ-FHNA MSZ-FH5NA MSZ-FH8NA MSZ-FH8NA (MSZ-FH0/09/NA) (MSZ-FH5/8NA/8NA) (MSZ-FH0/09/NA) (MSZ-FH5/8NA/8NA) MUZ-FH0NA MUZ-FH0NAH MUZ-FH09NA MUZ-FH09NAH MUZ-FHNA MUZ-FHNAH MUZ-FH09NA- REQUIRED SPACE * in. (00 mm) when front and sides of the unit are clear in. (00 mm) clear * in. (00 mm) (MUZ-FH0/09/NA) (MUZ-FH0/09/NAH) 8 in. (00 mm) * in. (350 mm) * When any sides of left, right and rear of the unit are clear x hole 3/8 x 3/ Liquid refrigerant pipe joint Refrigerant pipe (flared) Ø / Gas refrigerant pipe joint Refrigerant pipe (flared) Ø 3/8 OBH83D OBH83D 30 Satellite Boulevard. Suwanee, GA 300 Toll Free: 800-33-8 www.mehvac.com FORM# MSZ-FH09NA ~ MUZ-FH09NA- - 003 0 Mitsubishi Electric US, Inc.
M-SERIES SUBMITTAL DATA: MSZ-FHNA & MUZ-FHNA-,000 BTU/H WALL-MOUNTED HEAT PUMP SYSTEM Job Name: System Reference: Date: Electrical Power Requirements 08 / 30V, -Phase, 0 Hz ACCESSORIES: Unit Unit: MSZ-FHNA Wireless Remote Controller Condensate Pump (BlueDiamond X87-7/7; 5/30V) Condensate Pump (Sauermann SI30-5/30; 5/30V) Replacement Platinum Deodorizing Filter (MAC-3000FT-E) Replacement Anti-allergy Enzyme Filter (MAC-330FT-E) Air Discharge Guide (MAC-889SG) Base Pan Heater (MAC-0BH-U) Drain Socket (MAC-80DS) Controls : MUZ-FHNA- Wireless Controller (MHK) Wired Remote Controller PAR-3MAA (Requires MAC-333IF-E) Wireless Interface for kumo cloud (PAC-WHS0WF-E) Thermostat Interface (PAC-USCN-) SPECIFICATIONS: Rated Conditions (Capacity / Input) Btu/h / W,000 / 870 at 7º F Btu/h / W 3,00 / 950 Capacity Range Minimum Maximum Btu/h,500 3,00 at 7º F Btu/h 3,700,000 at 7º F 3 Btu/h - 3,00 at 5º F Btu/h - 3,00 : 80º F(7º C)DB / 7º F(9º C)WB; Outdoor: 95º F(35º C)DB / 75º F(º C)WB * at 7ºF : 70º F (º C)DB / 0º F (º C)WB; Outdoor: 7º F (8º C)DB / 3º F (º C)WB * 3 at 7º F : 70º F(º C)DB / 0º F(º C)WB; Outdoor: 7º F(-8º C)DB / 5º F(-9º C)WB * at 5º F : 70º F (º C)DB / 0º F(º C)WB; Outdoor: 5º F(-5º C) DB / 5º F(-5º C)WB * Rating Conditions per AHRI Standard: Operating Conditons ( Intake Air Temp.) (Max./ Min.) 90º F (3º C) DB / 7º F (9º C) DB 80º F (7º C) DB / 70º F (º C) DB Operating Conditons (Outdoor Intake Air Temp.) (Max./ Min.) 5º F (º C) DB / º F (-0º C) DB 75º F (º C) DB / -3º F (-5º C) DB** 5 Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. ** System cuts out at -8º F (-8º C) to avoid thermistor error and automatically restarts at -º F (-º C). AHRI Efficiency Ratings SEER / HSPF. /.5 COP at 7 o F / 7 o F. / 3.3 Energy Star Yes ENERGY STAR products are third-party certified by an EPA-recognized Certification Body. Minimum Circuit Ampacity (MCA) / Outdoor A / Unit Blower Motor (ECM) F.L.A. 0.7 Blower Motor Output W 30 SHF / Moisture Removal 0.83 /.9 pt./h Field Drainpipe Size O.D. 5/8 (5) Compressor Fan Motor (ECM) F.L.A. 0.50 Airflow Rate (Lo - Med - Hi - Super Hi - Powerful) () () DRY CFM DC INVERTER-driven Twin Rotary 37-7--30-398 WET 7-3-90--3 DRY 0-7-5-35-5 Outdoor,90 /,30 Sound Pressure Level (Lo - Med - Hi - Super Hi - Powerful) Outdoor External Dimensions (H x W x D) Outdoor (H x W x D) Net Weight db(a) 9 --9-3- --9-3- 5 Lbs.(kg) + / x 3-7/ x 9-3/ (305 +7 x 95 x 3) -5/8 x 3-/ x -/ (550 x 800 x 85) 9 () Outdoor 83 (38) External Finish Munsell.0Y 9. / 0. Outdoor Munsell No. 3Y 7.8 /. Refrigerant Refrigerant Piping (Flared) Liquid (High Pressure) R0A; lb. 9 oz. / (.35) Gas (Low Pressure) 3/8 (9.5) Pipe Length (Height Diff.) Pipe Length (Length.) Ft. (m) 0 () 5 (0) 0 Mitsubishi Electric US, Inc.
DIMENSIONS: MSZ-FHNA & MUZ-FHNA- MSZ-FH0NA MSZ-FH09NA MSZ-FHNA MSZ-FH5NA MSZ-FH8NA MSZ-FH8NA MSZ-FHNA MSZ-FH0NA MSZ-FH09NA MSZ-FHNA MSZ-FH5NA MSZ-FH8NA MSZ-FH8NA (MSZ-FH0/09/NA) (MSZ-FH5/8NA/8NA) (MSZ-FH0/09/NA) (MSZ-FH5/8NA/8NA) MUZ-FH0NA MUZ-FH0NAH MUZ-FH09NA MUZ-FH09NAH MUZ-FHNA MUZ-FHNAH MUZ-FHNA- REQUIRED SPACE * in. (00 mm) when front and sides of the unit are clear in. (00 mm) clear * in. (00 mm) (MUZ-FH0/09/NA) (MUZ-FH0/09/NAH) 8 in. (00 mm) * in. (350 mm) * When any sides of left, right and rear of the unit are clear x hole 3/8 x 3/ Liquid refrigerant pipe joint Refrigerant pipe (flared) Ø / Gas refrigerant pipe joint Refrigerant pipe (flared) Ø 3/8 OBH83D OBH83D 30 Satellite Boulevard. Suwanee, GA 300 Toll Free: 800-33-8 www.mehvac.com FORM# MSZ-FHNA ~ MUZ-FHNA- - 003 0 Mitsubishi Electric US, Inc.
M-SERIES SUBMITTAL DATA: MSZ-FH5NA & MUZ-FH5NA 5,000 BTU/H WALL-MOUNTED HEAT PUMP SYSTEM Job Name: System Reference: Date: Electrical Power Requirements 08 / 30V, -Phase, 0 Hz ACCESSORIES: Unit Unit: MSZ-FH5NA Wireless Remote Controller : MUZ-FH5NA Condensate Pump (BlueDiamond X87-7/7; 5/30V) Condensate Pump (Sauermann SI30-5/30; 5/30V) Replacement Platinum Deodorizing Filter (MAC-3000FT-E) Replacement Anti-allergy Enzyme Filter (MAC-330FT-E) Air Discharge Guide (MAC-88SG-E) Base Pan Heater (MAC-BH-U) Drain Socket (MAC-85DS) Controls Wireless Controller (MHK) Wired Remote Controller PAR-3MAA (Requires MAC-333IF-E) Wireless Interface for kumo cloud (PAC-WHS0WF-E) Thermostat Interface (PAC-USCN-) SPECIFICATIONS: Rated Conditions (Capacity / Input) Btu/h / W 5,000 /,00 at 7º F Btu/h / W 8,000 /,300 Capacity Range Minimum Maximum Btu/h,50 9,000 at 7º F Btu/h 5,50,000 at 7º F 3 Btu/h - 8,000 at 5º F Btu/h - 8,000 : 80º F(7º C)DB / 7º F(9º C)WB; Outdoor: 95º F(35º C)DB / 75º F(º C)WB * at 7ºF : 70º F (º C)DB / 0º F (º C)WB; Outdoor: 7º F (8º C)DB / 3º F (º C)WB * 3 at 7º F : 70º F(º C)DB / 0º F(º C)WB; Outdoor: 7º F(-8º C)DB / 5º F(-9º C)WB * at 5º F : 70º F (º C)DB / 0º F(º C)WB; Outdoor: 5º F(-5º C) DB / 5º F(-5º C)WB * Rating Conditions per AHRI Standard: Operating Conditons ( Intake Air Temp.) (Max./ Min.) 90º F (3º C) DB / 7º F (9º C) DB 80º F (7º C) DB / 70º F (º C) DB Operating Conditons (Outdoor Intake Air Temp.) (Max./ Min.) 5º F (º C) DB / º F (-0º C) DB 75º F (º C) DB / -3º F (-5º C) DB** 5 Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. ** System cuts out at -8º F (-8º C) to avoid thermistor error and automatically restarts at -º F (-º C). AHRI Efficiency Ratings SEER / HSPF / COP at 7 o F / 7 o F.0 / 3.9 Energy Star Yes ENERGY STAR products are third-party certified by an EPA-recognized Certification Body. Minimum Circuit Ampacity (MCA) / Outdoor A / Unit Blower Motor (ECM) F.L.A. 0.7 Blower Motor Output W 30 SHF / Moisture Removal 0.70 /.0 pt./h Field Drainpipe Size O.D. 5/8 (5) Compressor Fan Motor (ECM) F.L.A. 0.93 Airflow Rate (Lo - Med - Hi - Super Hi - Powerful) () () DRY CFM DC INVERTER-driven Twin Rotary 5--30-355- WET 9-5--305-35 DRY 0-5-37-39-97 Outdoor,0 /,0 Sound Pressure Level (Lo - Med - Hi - Super Hi - Powerful) Outdoor External Dimensions (H x W x D) Outdoor (H x W x D) Net Weight db(a) 7-3-35-39- 5-9-3-39- 55 Lbs.(kg) + / x 3-7/ x 9-3/ (305 +7 x 95 x 3) 3-5/8 x 33-/ x 3 (880 x 80 x 330) 9 () Outdoor (5) External Finish Munsell.0Y 9. / 0. Outdoor Munsell No. 3Y 7.8 /. Refrigerant Refrigerant Piping (Flared) Liquid (High Pressure) R0A; 3 lb. 7 oz. / (.35) Gas (Low Pressure) / (.7) Pipe Length (Height Diff.) Pipe Length (Length.) Ft. (m) 50 (5) 00 (30) 0 Mitsubishi Electric US, Inc.
AND DIMENSIONS A MSZ-FHNA MSZ-FH5NA DIMENSIONS: MSZ-FH8NA MSZ-FH5NA MSZ-FH8NA& MUZ-FH5NA MSZ-FH5NA MSZ-FH0NA MSZ-FH09NA MSZ-FHNA MSZ-FH5NA MSZ-FH8NA MSZ-FH8NA (MSZ-FH5/8NA/8NA) (MSZ-FH0/09/NA) (MSZ-FH5/8NA/8NA) MUZ-FH5NA MUZ-FH5NAH MUZ-FH8NA MUZ-FH8NAH MUZ-FH8NA MUZ-FH8NAH 3 MUZ-FH5NA Air in -7/ Air in -7/ Air in Drain hole -9/ Drain hole -9/ * 0 in. (500 mm) when front REQUIRED and sides of the SPACE unit are clear -5/8-3/ REQUIRED SPACE * 0 in. (500 mm) when front and sides of the unit are clear -5/8 in. (00 mm) in. (00 mm) Clear * Clear * in. (00 mm) in. (00 mm) 3 Air in Air out -7/8 9-/ Air out -7/8 9-/ 33-/ -5/ 33-/ -5/ -3/ x hole 3/3 x 3/ x hole 3/3 x 3/ 3-3/ 3-3/ 0 in. (500 mm) * in. (350 mm) in. (350 mm) * When any sides of left, right and rear of the unit are clear 0 in. (500 mm) * * When any sides Service of left, panel right and rear of the unit are clear Service panel Liquid refrigerant pipe joint Refrigerant pipe (flared) Ø / 3-5/8 Liquid refrigerant pipe joint Refrigerant pipe (flared) Ø / 3-5/8 7-5/3 7-5/3 OBH83D FORM# MSZ-FH5NA / MUZ-FH5NA - 003 -/ 3-9/3 -/ 3-9/3 7-/ 7-/ 35 35 Gas refrigerant pipe joint Refrigerant pipe (flared) Ø / Gas refrigerant pipe joint Refrigerant pipe (flared) Ø / 30 Satellite Boulevard. Suwanee, GA 300 Toll Free: 800-33-8 www.mehvac.com 0 Mitsubishi Electric US, Inc.
M-SERIES SUBMITTAL DATA: MSZ-FH8NA 8,000 BTU/H WALL-MOUNTED INDOOR UNIT FOR MXZ-C MULTI-ZONE HEAT-PUMP SYSTEMS Job Name: System Reference: Date: SPECIFICATIONS: Rated Capacity* Btu/h / W 7,00 at 7º F Btu/h / W 0,300 Unit: MSZ-FH8NA Wireless Remote Controller ACCESSORIES: Unit Condensate Pump (BlueDiamond X87-7/7; 5/30V) Condensate Pump (Sauermann SI30-5/30; 5/30V) Replacement Platinum Deodorizing Filter (MAC-3000FT-E) Replacement Anti-allergy Enzyme Filter (MAC-330FT-E) Controls Wireless Controller (MHK) Wired Remote Controller PAR-3MAA (Requires MAC-333IF-E) Wireless Interface for kumo cloud (PAC-WHS0WF-E) Thermostat Interface (PAC-USCN-) Rating Conditions per AHRI Standard: : 80º F(7º C)DB / 7º F(9º C)WB; Outdoor: 95º F(35º C)DB / 75º F(º C)WB at 7º F : 70º F (º C)DB / 0º F (º C)WB; Outdoor: 7º F (8º C)DB / 3º F (º C)WB For data on specific indoor units (all ducted, all non-ducted, and both ducted and non-ducted) combinations, see the MXZ Technical and Service Manual. Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. Electrical Power Requirements Minimum Circuit Ampacity (MCA) 08 / 30V, -Phase, 0 Hz A Blower Motor (ECM) F.L.A. 0.7 Blower Motor Output W 30 Field Drainpipe Size O.D. 5/8 (5) Airflow Rate (Lo - Med - Hi - Super Hi - Powerful) DRY CFM 5--30-355-37 WET 9-5--305-37 DRY 0-5-37-39-5 Sound Pressure Level (Lo - Med - Hi - Super Hi - Powerful) db(a) 7-3-35-39- 5-9-3-39- External Dimensions (H x W x D) + / x 3-7/ x 9-3/ (305 +7 x 95 x 3) Net Weight Lbs.(kg) 9 () External Finish Munsell.0Y 9. / 0. Refrigerant Piping (Flared) Liquid (High Pressure) / (.35) Gas (Low Pressure) / (.7) 05 Mitsubishi Electric US, Inc.
Piping Ø O.D Ø3/8 9-/ (Flared connection Ø3/8) Ø/ 7-/ (Flared connection Ø5/8) Insulation Ø-/8 Connected part Ø5/8 O.D MSZ-FH8NA MSZ-FHNA MSZ-FH5NA MSZ-FH8NA MSZ-FH09NA Unit: mm (in.) 7/ -/ Oblong hole unit -5/8-3/ 5-9/ -/ 0-/8 3-9/ Wall hole Ø3 Air in 9-3/ 7-/ -9/ -5/ / Air out -3/ -3/8 Piping / / 9-5/8-3/8 3-5/ Installation plate -5/8 3/8 8-/8 3/ -3/ -/ 7/8 8-7/8 8-/ 3/8 9-5/ 0-3/ 35-5/8-7/8 3-7/ 8-7/8 9-/ 7/ 3/ Oblong hole Installation plate -/ 8-/ -9/ -7/8 -/ -/ -/ Insulation Liquid line Gas line Drain hose DIMENSIONS: MSZ-FH8NA -3/ -9/ Drain hose -5/8-5/8 Piping (MSZ-FH09/NA) Insulation Liquid line Gas line Drain hose Ø-7/ O.D Ø/ 9-/ (Flared connection Ø/) Ø3/8-5/ (Flared connection Ø3/8) Insulation Ø-/8 Connected part Ø5/8 O.D -/ (MSZ-FH5/8NA) Piping 7-5/8 5-3/ Insulation Liquid line Gas line Drain hose Ø-7/ O.D Ø/ 9-/ (Flared connection Ø/) Ø3/8-5/ (Flared connection Ø/) Insulation Ø-/8 Connected part Ø5/8 O.D 9 30 Satellite Boulevard Suwanee, GA 300 Toll Free: 800-33-8 www.mehvac.com FORM# MSZ-FH8NAFOR MXZ-C MULTI-ZONE SYSTEMS - 003 05 Mitsubishi Electric US, Inc.