Refrigerant Valves/Accessories

Similar documents
Intelligent Refrigeration Solutions

RESEARCH AND TECHNOLOGY BUILDING RENOVATION 05/18/09 SECTION REFRIGERANT PIPING AND SPECIALITIES

TECHNICAL. Series 18. Pump Packages

HYDRONIC SPECIALTIES TACO AC(F)-PAX 05/15/2008

HYDRONIC SPECIALTIES TACO AC(F)-CA 05/08/2008

REFRIGERATION PRODUCTS

Peerless Pump Company

DESIGN STANDARDS SECTION 15600

HYDRONIC SPECIALTIES TACO MPT Tank(s) 05/30/2012. A. Multi-Purpose Tank buffer tank, air separator, and hydraulic decoupler

PULSE WIDTH MODULATING VALVES

Salinas Valley Ammonia Safety Day. May 26, 2011 Salinas, CA

Essex County College - West Essex Campus Addition And Renovations dib # / SECTION HYDRONIC PIPING SPECIALTIES PART 1- GENERAL

PACKAGED AIR COOLED Product Data Catalog

Specifications, Applications, Service Instructions & Parts FROST MASTER & FROST MASTER PLUS DEFROST CONTROLLERS

Reciprocating Simplex and Duplex Tank Mount Compressor Systems Rev. 08/23/12

AUTO-PURGER AP. Noncondensible Gas (Air) Refrigerant Purger. Model APW OPERATOR INSTALLATION & INSTRUCTION MANUAL

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

CME1856W Service Parts

Industrial Refrigeration Defrost Solutions TM Package. Brochure R-222

Flow Control for Fire Protection

Pump & Trap Combinations

SECTION AIR COMPRESSORS AND ACCESSORIES

SECTION STEAM CONDENSATE PUMPS

The rotary type compressor consists of an integrally formed rotor and shaft, five vanes, and a cylinder.

CME1856W Service Parts

EFFECTIVE: MAY, American Dish Service ADS MODEL: ASQ GLASSWASHER PARTS MANUAL. 900 Blake Street Edwardsville, Kansas (913) /08

Our Know-How. Your Peace of Mind. Steam Solutions

SOLENOID VALVES FOR REFRIGERATING SYSTEMS

INSTALLATION INSTRUCTIONS

SECTION HEATING BOILER FEEDWATER EQUIPMENT

Flow Control for Fire Protection

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

water source / fan coils

SECTION 1 MOUNTING & PIPING INSTALLATION. INSTALLATION DIMENSIONS (MM) Figure 1

HORIZONTAL FIRE TUBE BOILERS Piping (HVAC) Pumping Equipment (HVAC).

APT and APT14 Automatic Pump Traps. for effective condensate drainage and removal

HVAC BASIC MATERIAL AND METHODS 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."

Section H11 BLOWDOWN SEPARATORS CONTENTS FEATURES AND BENEFITS...H11-3 PRODUCT OFFERING...H11-3 SAMPLE SPECIFICATIONS...H11-11 ILLUSTRATIONS

SECTION REFRIGERANT PIPING

Liquid Drainers LIQUID DRAINERS

Model 10AB/APRB Automatic Dishwasher

DTW Works Master Specification Version 2006 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5

TEMPERATURE & PRESSURE CONTROLS

FLO-RITE-TEMP INSTANTANEOUS WATER HEATER INSTALLATION AND ADJUSTMENT INSTRUCTIONS FOR SINGLE AND DOUBLE WALL UNITS

T E C H N O L O G I E S P R O D U C T C A T A L O G

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

Essex County College - West Essex Campus Addition And Renovations dlb # / 11-14

Direct Fired Heater Model AD Specification

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

AUTO-PURGER M OPERATOR INSTALLATION & INSTRUCTION MANUAL. ENERGY SAVER Compact, Noncondensible Gas (Air) Purger ISO For 115V and 230V Models

.2 Section Waste Management and Disposal.

SECTION METERS AND GAGES FOR PLUMBING PIPING

PowerPoint Presentation by: Associated Technical Authors. Publisher The Goodheart-Willcox Company, Inc. Tinley Park, Illinois

Hydrocarbon & Chemical Processing Solutions

SECTION COMPRESSED AIR SYSTEM. A. Pipe and pipe fittings, including valves, unions and couplings.

OPERATING AND MAINTENANCE MANUAL FOR INSTANTANEOUS STEAM FIRED WATER HEATER ELECTRIC HEATER COMPANY BASE MODEL F

REPLACEMENT PARTS MANUAL FOR MODEL: PWS 45-75, AED-2 & APK-4 SERIES

Owner's Manual. (200 Gallon Lawn Service Skid Sprayer) Technical Specifications. Operation. General Information. Warranty/Parts/Service

LABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS

SECTION AIR COOLED WATER CHILLERS

Full-line Product Overview

SECTION HYDRONIC PIPING AND SPECIALTIES

Oil burners fuel unit with solenoid valve

MCBV MOTOR CONTROLLED BALL VALVES

PT15 MATERIAL : DIMENSIONS - Nominal in inches. AVAILABLE SPARES: Disc (Packet of 5) ORDERING INFORMATION: Refer to "HOW TO ORDER" page.

Service Manual. Models 17700/17701/17703 Recovery/Recycling/Recharging Unit For R-12 Only

ACADEMIC SUCCESS CENTER THE COLLEGE AT BROCKPORT STATE UNIVERSITY OF NEW YORK PROJECT NO

Parts List. Modular Crescent Cuber. Models KM-515MAJ, MWJ, MRJ. hoshizakiamerica.com

UNIVERSITY OF MISSOURI Building Hydronic Piping and Pump Systems 2017 Q3

Air-Cooled Condensing Units with Compact Screw Compressors

Dean Pump High Temperature Chemical Process Inline Pumps

Revolutionary ETS Colibri valves Engineered to give you maximum flexibility and dependability

Sporlan Valve Division Parker Hannifan/CIC Group

Glass Washer. PERLICK Glass Washer NO ONE WORKS HARDER TO KEEP YOU COOKING. WHALEY FOODSERVICE REPAIRS ITEM PART NO. NO.

Industrial Refrigeration. Brochure R/S CB 02/10

XSTREAM Valve System With A.R.M.E.D. Technology Service & Installation Instructions Page 1

PROJ. NO SECTION REFRIGERANT PIPING

UNIVERSAL STYLE STEAM TRAPS WU450 Series

MYSTICOOL Max Valve System with Xstream and A.R.M.E.D. Technology Service & Installation Instructions Page 1

Float & Thermostatic Steam Traps for efficient condensate drainage of industrial process and HVAC equipment

Vent-Rite. Cast Iron And Steel Receivers. Simplex, Duplex, Triplex And Quadruplex Units. Pump Capacities To 150 GPM. Discharge Pressure To 75 PSI

CHILLER. Operator s & Installation Manual

Silhouette. Feedwater Heater. Boiler Feedwater

Parts List. Modular Crescent Cuber. Models KM-901MAJ KM-901MWJ KM-901MRJ/3. hoshizakiamerica.com

BBSS BASIC BOTTLE SAMPLING SYSTEM

REFRIGERANT PIPING SYSTEM

SECTION DOMESTIC WATER PIPING SPECIALTIES

University of Delaware

Diesel Exhaust Fluid Compatible Products DEF

Commercial, Residential & Institutional Pumps, Tanks, & Accessories

VALVES SECTION 15100

TM Series. Induced Draft, Counter Flow Optional Accessories

Paragon. Induced Draft, Counter Flow Optional Accessories

Wallace & Tiernan Gas Feed Systems V2000 Chlorinator

IMAGE V. Parts and Service Manual

Oil burners fuel unit with solenoid valve

ORTEC HIGH CAPACITY REFRIGERATED AIR/GAS DRYERS

Transcription:

Inline Check Valves Compact in-line (non-return) check valves for closure upon pressure reversals. Low Pressure Drop Mounts In Any Position Stainless Steel Disc Safe Working Pressure 400psig Operating Temp. 60F To +240F To order, specify: type, flange connection, style and size Refrigerant Strainers for use in liquid lines, hot gas lines, suction lines and oil lines. SS screen 60 mesh Generous flow area Groove inlet, tongue outlet Safe working pres. = 400psig Installed as either separate or closed coupled unit To order, specify: catalog number, installed as either seperate or closed coupled unit, and if flanges are necessary (size & type) Piston Type Check Valves Flanged, heavy duty, piston type check valves for closure upon pressure reversals High flow capacity Manual opening stem Bonnet servicable Rugged design To order, specify: type, flange connection, style and size Refrigerant Float Switches Used to electrically indicate or control a liquid level Rugged 10 amp switching capacity Simple,direct switch pivot arm Optional switch housing heater Safe working pres @ 400psig Operating temp -50f to +150f

Refrigerant Liquid Level Indicators Features a reflex lens which appears dark in the presence of liquid and light when liquid is absent. Frost shield is an option. Asme sa36 housing material 3.25 Long universal housing Reflex lens standard Safe working pres. @ 400psig Operating temp -60f to +240f Refrigerant Shut-Off Valves Rugged valves for industrial refrigeration featuring ball bearing swivel seats, no leak stem seal design and back seating for stem seal replacement. Using either handwheel or seal cap. Flanges ¼ to 1 ¼ using oval 2-bolt style 1 ½ to 4 size, uses 4-bolt square style To Order: Specify Flange Number Size, Flange Kit connection style and size.

Refrigerant Valves Refrigerant Solenoid Valves Designed for industrial refrigeration. High quality, compact, strong bodied and reliable. Spring closing with teflon seats Pressure drop is low One solenoid coil fits all valves 300psi MOPD 400psig safe working pressure Suitable of ammonia, R22, R134a, etc. -60F to +240f To order, specify the following: Type & Port Connection Style & Size Coil Connection Style Voltage Strainer

Refrigerant Hand Expansion Valves Featuring unique slotted plugs for accurate flow regulation along w/teflon seat discs for tight closing. Valve stems are stainless steel w/double seals to eliminate stem leakage. Defrost Controller Utilized for operation of various control valves and fan relays to quickly remove frost/ice accumulation from evaporator surfaces. Precision quartz clock 24Hour or 7 day scheduling 10AMP, SPDT relay Stepping button for trials NEMA 4 enclosure Refrigerant Gauge, Purge & Needle Valves Seal cap, bar handle or bare stem Stainless steel stem Plated forged steel body Non-removable safety stem Non-leak stem packing design Compact size For R22, R134a

Refrigerant Valves Refrigerant Pressure Regulators Designed for simple, reliable operation utilizing a series of easily changed modules(pilots) to determine regulating function(s). strong ductile iron or steel body disc-piston w/teflon seal ring V-port modulation for finer control Suitable for Ammonia, R22, R134a Safe working pressure of 400psig Temperature of 60F to +240F To order specify the following: Type & Port Connection Style & Size Voltage where applicable Special Variations Strainer if required Type Of Regulator Variations Special Variations (Pilots) On Regulators