K Series Modular air conditioners. With direct expansion coil With chilled water coil

Similar documents
TECNAIR LV C series Close control air conditioners

TECNAIR LV C series Close control air conditioners

YORK Close Control units

YORK YC-P Series Close Control Air Conditioners

H Series Surgical room air conditioners. with direct expansion coil: OHA series with chilled water coil: OHU series

Precision air handling cabinets Ciatronic MICRO/EXPAIR

EXPAIR. Use. Precision air handling cabinets. Reducted footprint Dual-wall construction

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

> Refrigerant R-410A. Uniflair LE TDER-TUER kW. Energy-saving units with backward-curved fans. Perimeter cooling for medium/large data center

Vertical self-contained air conditioner

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

SELF CONTAINED HORIZONTAL AIR CONDITIONERS WATER COOLED CONDENSER (COAXIAL REFRIGERANT-WATER HEAT EXCHANGER)

Next P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB


Dehumidification and ventilation for residential, industrial radiant systems and swimming pools

NEXT EVO DXR410A NEXT EVO DX NEW SOFTWARE. rcgroupairconditioning

CIATCOOLER LJA. Chilled water production units USE. Attractive design, Compact and quiet

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

CATALOGUES SUMMARY - WCHBZ Pages WCHZ Pages 19-42

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

Split-system cooling units and heat pumps SERIES. Outdoor unit. Indoor unit OPERATING LIMITS. Inlet air conditions Cooling Heating.

BETA ECHOS. Air/water cooled chillers and heat pumps kw. General BETA ECHOS is a range of chillers and ductable air-water heat pumps.

VariCool VAV Engineering Guide

MAGISTER. Compact and attractive design Energy savings with EC motor and self-regulating control. Easy to install. Use. Chilled water operation

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

Next MTR kw. technicalcatalogue. Air conditioners for Metrology Labs with upflow air delivery T_NXTMTR_0511_GB

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

50CO. Close Control Unit. Wide range of chilled water cabinets. Compact and attractive design. EC motor for energy savings. Auto-adaptive control

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

FHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions

HIGH EFFICIENCY POOL DEHUMIDIFIER AND CONDITIONER WITH HIGH HEAT RECOVERY RATES. Air treatment unit. Swimming pool waste air 28 C-65%

2013 Product Range Precision Air Conditioners (CRAC)

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES

next evo cw next evo cw rcgroupairconditioning

DATATECH. Precision air conditioners for technological environments 6 220

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

GHE Dehumidifiers for radiant cooling systems with heat recovery

GHE GHE. Dehumidifiers for radiant cooling systems with heat recovery VERSIONS ACCESSORIES

Galletti Water chillers and heat pumps catalogue

AIRSYS-P-SC-CHILLROW-E1503V01.1 CHILLROW. Row Cooling Precision Air Conditioner. Cooling Capacity: 26.2kW~68.6kW

Chilled Water Precision Air Conditioner for Critical Application

Control Systems. Design & Manufacturing. Eco-Friendly. High Performance

SPLIT System. SPLIT System Simple and flexible direct expansion solutions for the commercial sector and industry

LZT High efficiency air to water heat pumps with E.V.I. compressors

Flexible & Innovative. Cooling Solutions

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS

Process glycol chillers

GHE. Dehumidifiers for radiant cooling systems with heat recovery. Display

next p dw next p dw rcgroupairconditioning

RC GROUP. MULTIPLO.A.STD/ELN G Multifunctions air cooled liquid chillers with Scroll compressors and axial fans R407C. SCROLL compressors kw

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR

20-120RT Multi-functional Modular Combination High Efficiency & Energy Saving Keeping Technology Cool

COOLROW Close control air conditioners for In-Row installation Cooling Capacity: kw

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

NEXT DL NEXT DL. rcgroupairconditioning

air systems Large Rooftop DIC-BIH-DIG 360 to 480 G

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

AQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual

Series PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS. Features:

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

DATATECH PFW kw. Quick facts

Большая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10

FLOWAY. Floway Range. The dual-flow air handling unit with heat recovery guaranteeing an Economical and Durable solution. use.

Chiller units and air-water heat pumps RANGE OPERATING LIMITS

PRODUCT DOCUMENTATION

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

york airside products Tailored air conditioning solutions Introducing the YORK YPRE range of custom air-to-air packaged roof top units

i-chiller 181 to 210 kw ic770 to ic780 ABOUT THE i-chiller RANGE RELIABILITY: ENERGY & PROCESS EFFICIENCY: EASE OF OPERATION & MAINTENANCE:

ED.X F Kc DIRECT EXPANSION CLOSE CONTROL UNITS WITH REMOTE CONDENSERS AND ADDITIONAL CHILLED WATER FREE COOLING COIL

Water chillers water/water type SIGMA Technical information manual

Packaged air conditioning unit condensed by air model RTC 07L to 30L. Technical information. Ref.: Y-R

Packaged air conditioning unit condensed by air model RTC 07L to 30L. Technical information. Ref.: N

All series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly.

condenciat cl Condensing units Outdoor condensing unit Variable speed propeller fan Use Description for direct expansion applications

Dehumidification and ventilation for residential, industrial radiant systems and swimming pools

DC Inverter Smart VRF Products(R410A)

PRODUCT DOCUMENTATION

LDK LDK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump

E U R O V E N T CERTIFIED PERFORMANCE

4,5 22,5 kw. technicalcatalogue. Air-conditioned server-racks for direct installation into the room T_CLSEVO_0113_GB

pyxis pyxisa NEW rcgroupairconditioning

High temperature air-to-water heat pumps

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw. Scroll Compressors SCAEY-FC DE 98

LSK LSK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

GEA Ultra-Denco. GEA Heat Exchangers / HVAC Systems. Close Climate Control for IT Environments. Reliability with low power consumpstion

Air treatment units 0932EN October 2017 Dehumidifier unit for radiant systems Flush-mounting installation in false ceilings

Series. Packaged Rooftop Units, heat pumps and Outdoor air handling Units. Features:

TECAM S.A. harmony. 5PZA Direct Expansion. Air Conditioning Equipment Manufacturer. R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz. Tecnología Ambiental

Air Cooled Scroll Chiller

Hi-Pres. Self Contained A/C Unit HI-PRES MARINE & OFFSHORE

CLOSE CONTROL AIR CONDITIONERS

Integrated VarIable refrigerant flow ahu/pau (r410a)

IT COOLING CLOSE CONTROL AIR CONDITIONERS PRECISION AIR CONDITIONERS WITH INVERTER TECHNOLOGY FOR STABLE ROOM CONDITIONS

Transcription:

K Series Modular air conditioners With direct expansion coil With chilled water coil

K Series Modular air conditioners With direct expansion coil With chilled water coil Designed for precision and comfort applications K Series modular air conditioners are available in the following versions: of the units with downflow air discharge (UK) are equipped with hydrophilic aluminium fins, which eliminate any possible condensate entrainment in the airflow and avoid the lower part of the coil from getting full of water, so reducing the heat exchange and therefore the capacity delivered by the air conditioners. H : (high air flow), with high airflow compared to the cooling capacity. They are designed for air conditioning of central offices, computer centres, high-automated offices, and special close control uses. L : (low air flow), with low air flow compared to the cooling capacity, suitable for application into common business and tertiary environments, such as conference rooms, restaurants, libraries, and museums. Their modularity allows coping with increasing cooling demand by installing additional units beside the original ones. The use of the ecologic refrigerant HFC R407C contributes to the conservation of the environment (unit with R 22 available on request) The high aeraulic efficiency of the units with downflow air discharge is due, for the units equipped with direct expansion circuit, to the fan which is positioned centrally, instead of in the base, with a downflow duct that partially recovers the dynamic pressure, improves the system effect, and involves lower fan energy consumption. Thanks to its larger surface, the filter on the coil allows lower crossing speed, which results in lower pressure drop. The lower energy consumption of these air conditioners, at the same efficiency, results in a very reduced TEWI (Total equivalent warming impact). Silent functioning, energy efficiency, and ecological impact The scroll compressors of K series air conditioners with direct expansion coil are more silent than the alternative ones; they are contained as well into an acoustically insulated compartment, outside the air flow, which improves its working soundlessness still further. The scroll compressors have energy consumptions much lower than the other compressors, so limiting the ecological impact. Both the chilled-water and direct-expansion cooling coils Minimum foot print and front maintenance Space inside technological rooms is always a precious thing. This is why Tecnair LB s modular air conditioners are specially designed for minimising their footprint. All ordinary and extraordinary maintenance activities, barring exclusively the replacement of heat-exchange coils, are executed from the front side of the unit, so allowing installing several units close one each other and not sacrificing precious side space to this purpose. The hinged front doors make the access to the inside parts easy and quick.

Features and performance Microprocessor regulation The µac microprocessor allows managing all the typical air-conditioning functions cooling, heating, humidification, dehumidification, and filtering very accurately and timely. It assures a regular and optimised functioning as to both performance and consumption; it also provides for alarm management and self-diagnosis. If you need to install any component requiring analogical control (modulating valve or electronic hot-gas by-pass valve), the pco 2 microprocessor (optional) shall be installed in lieu of standard µac. Local network management or remote control Series K air conditioners can work in local-network mode, that is, with several units (up to 6) in the same room. A unit slaves all the others, in such way as to intervene in case of a peak load or of an emergency. All master units become slave in turn on a regular basis (e.g. every 12 or 24 hours) in order to equalise the number of running hours. In remote control mode, up to 64 units can be controlled even from remote positions, via modem, both through a special supervisory program by Tecnair LB and through a Gateway and a Modbus or Bacnet communication protocol, by any BMS. Cooling circuit The air conditioners with direct expansion coil have a frigorific circuit equipped with: scroll compressor with all necessary protective devices: high pressure (manual reset) and low pressure (automatic reset) switches, thermal expansion valve, dehydrating filter with refrigerant sight glass. OKA UKA models for pairing with remote condensers, and OKE UKE models for pairing with remote condensing units, are already equipped with a pressurised refrigerant charge. The definitive charge, and the oil top-up (if required), shall be made by the installer on site. OKW & UKW air conditioners self-contained type with built-in water-cooled condenser, are supplied with full refrigerant and oil charge. Modulating regulation of the cooling capacity (units equipped with frigorific circuit) An electronically controlled hot gas injection valve (optional) allows obtaining a perfectly modulating regulation from 50% to 100% of the cooling capacity of the frigorific circuit. In case of necessity of a modulating regulation from 5% to 100% with very low tolerance, on the room temperature even with a high outdoor air flow, a further electronically controlled valve for refrigerant expansion shall be installed (option).

Both these application requires absolutely the pco 2 microprocessor (optional) instead of standard µac. Pressostatic regulation of the cooling capacity (units equipped with frigorific circuit) A mechanical hot gas injection valve allows obtaining a modulating regulation from 70% to 100% of the cooling capacity of the frigorific circuit. The valve regulation is made on the refrigerant suction pressure and overheating, and therefore the use of the pco 2 microprocessor (optional) is not mandatory. One or two parallel or independent compressors All the air conditioners have one frigorific circuit with one compressor compartimentated from the air flow, excluding these models: Size 131.2 is equipped with two scroll compressors tandem connected with a single cooling circuit allowing a remarkable increase of working C.O.P. with partial thermal loads, which are the most frequent during the life of the system, and therefore great operating cost saving. Installation costs are reduced too, thanks to the single external condenser connecting circuit. Sizes 101, 131 and 151 are equipped with one scroll compressor connected with a single cooling circuit. In this execution the compressor is not compartemented from the air flow. Conversely, sizes 72, 102, 132, and 152 are equipped with two scroll compressors and two independent cooling circuits, which assure the utmost working safety.

Hydraulic circuit Air conditioners with chilled water coil: OKU and UKU, include a finned coil and a three-way throttling motorised valve for water flow regulation. The hydraulic circuit is provided with copper tubes with anti-condensate insulation. The throttling valve (3 points) allows good modulation of the cooling capacity produced as a function of the environmental conditions, especially with constant thermal loads, as it responds quite slowly to their quick changes. Depending on the application, four-row coil units are available for water 7/12: in such case, the last number of the code is 4; alternatively, six-row coils are available too, for higher water temperatures: in this case, the last number is 6. Units with 6 rows cooling coil cannot have hot water ones. Modulating regulation of the cooling capacity (units equipped with chilled water coil) On the contrary, if a very precise regulation and response speed are required, a modulating valve (optional) can be installed in lieu of the throttling one. However, the modulating valve needs an analogue signal, not digital, so the installation of the pco 2 microprocessor (optional) is absolutely required. Fans The fan section is made of one or several centrifugal direct-driven single speed fans with double air-suction, mounted on antivibration supports functioning soundlessness. The static pressure available is suitable for most applications. However, external transmission is

available too on request (optional), if higher static pressure is required. Electric board All units are equipped with a complete electric board with main shutter-block switch. Magnetothermic switches, contactors, and all necessary protections are provided as well, as required by the Regulations in force. The electric board of the units equipped with compressors ( A or W as third letter of the identification code) have a standard phase sequencer, which prevents the compressor from getting damaged when counter running. Also, the board has two clean terminals for remote indication of a cumulative alarm, as well as two terminals for starting up and stopping the unit from remote position. The electric panel doesn t include the variator of the revolution number of the fans of the air cooled remote condensers (winter control). This device is standard included in the CEA and CEA/LN air cooled condensers from Tecnair LB. Anyhow should you decide to match the unit with a condenser from another Manufacturer, the variator can be ordered as accessory. Large surface filters The units are equipped with regenerative self-extinguishing class-g3 filters. The filters are installed inclined before the cooling coil in order to offer a larger surface and allow lower air crossing speeds, with lower energy consumption. Alternatively, efficiency-g4 filters can be installed too (optional). Design suitable to civil environments K Series air conditioners have a nice and functional design, suitable for installation in civil environments. Their structure consists of an anodised-aluminium plate frame onto which special galvanised-steel plate panels are hinged. These panels are coated with a light-grey PVC layer, thermo-acoustically insulated by a 25mm-thick polyurethane layer, and further coated with a plastic film. Two versions are available for up flow units (OK): front grille & top air discharge (standard), or blind front panel, suction from the bottom and top discharge (optional). For downflow units too there are two versions: suction from top and discharge from the bottom (standard) or suction from front panel and always discharge from the bottom one (optional). Fittings Electronic immersed-electrode modulating humidifier and dehumidification control Two-row hot-water heating-rehating coil with floating (three-way) adjusting valve One- or two-step thermally-protected low-heat-inertia heater- rehater Pressostatic two-way valves (OKW & UKW) Pressostatic three-way valves (OKW & UKW) Single phase variator of the revolution number of the condenser fans. Max. 8A Three-way modulating valve, in lieu of the floating one (units with only pco 2 only) pco 2 microprocessor in lieu of the standard µac Hot-gas injection and expansion electronic valves for a perfectly modulating cooling capacity regulation: 50% 100% (units with only pco 2 only) Additional electronic expansion valve for 5%- 100% regulation Pressostatic hot gas injection valve for cooling capacity regulation. G4 efficiency air filters in lieu of standard G3 Variable belt-drive and -pulley fans in lieu of standard direct driven fans. Power factor correction condenser for compressor Air discharge or suction plenum (h=450 mm) with front grille Air discharge or suction plenum (h=450 mm) with front and side grilles Adjustable under base. Specify the height dimension. Adjustable under base with air conveyor. Specify the height dimension. Sound damped hood (h=450 mm) for air discharge or suction. Allows approx. 4 db (A) reduction of unit SPL. Layer lead plate sound damping panels. Allow approx. 2 db (A) reduction of unit LPS (up flow air discharge models) (series OK), and approx. 4 db (A) reduction of unit LPS (downflow air discharge models) (series UK) Double skin panels with 25 mm insulation inside. Blind front panel (OK) and open base for bottom air intake Grilled front panels for UK units for front air intake. Gravity over-pressure dampers (series OK) on the air discharge mouth Motor-driven over-pressure dampers (series UK) on the air suction mouth Humidity sensor and modulating board for dehumidification control only, or remote humidifier control (not supplied by Tecnair) Clock board for time band control RS 485 communication board Water alarm (supplied loose) Out-of-range air active discharge temperature alarm

Special versions Free cooling, using renewable energy sources OKW - UKW/FC air conditioners (from model 71L) are equipped with a Free cooling system consisting of an additional chilled-water cooling coil integrated in the aluminium fins of the unit's direct expansion coil, with a three-way modulating valve controlled by the microprocessor. As long as the outside conditions allow the water to respond totally or partially to the cooling request, the microprocessor cuts out or minimises the compressors intervention, so reducing substantially the energy consumption. The three way pressostatic valve installed on the condenser allow constant water flow in the circuit so that the use of a variable speed pump is not requested. The pumps and the expansion tank are not included in Tecnair LB s supply. Units in free cooling version cannot install the option hot water heating coil, but only the electric one, and have as standard the pco 2 microprocessor The system widely uses the outdoor air a renewable energy source in lieu of or in addition to the mechanical cooling. FREE COOLING SYSTEM SPRING-AUTUMN WORKING (Direct expansion + chilled water) DRY COOLER DRY COOLER DRY COOLER FREE COOLING SYSTEM SUMMER WORKING (Direct expansion) FREE COOLING SYSTEM WINTER WORKING (Chilled water)

Two seasons, using excess of energy This system (available from model 71L) consists of the same chilled-water cooling coil as the Free cooling, but unlike those ones, this one is fed by the building water chiller. However, in this case too, the compressors are stopped or partially operated as long as the system cooling capacity is available. The excess of cooling power of the central system can be recovered for nearly all the year, so the direct expansion system is only used for summer peaks or in winter, when the system is either at the end of its capacity or out of order: The result is a remarkable reduction of both consumption and running costs. Units in two seasons cannot install the option hot water heating coil, but only the electric one, and have as standard the pco 2 microprocessor This system can also use the direct-expansion coil circuit as primary cooling source, and, in case of an emergency, the chilled-water coil connected with the city water network. AIR COOLED CONDENSER AIR COOLED CONDENSER TWO SEASON SYSTEM Working (chilled water) TWO SEASON SYSTEM Working (Direct expansion)

Technical characteristics OKA / UKA models with air- or water-cooled remote condenser 31-L 31-H 41-L 41-H 51-L 51-H 71-L 71-H 81-L 81-H 101-L 101-H 131-L 131-2L 131-H Cooling cap. total, kw 8,2 8,5 10,8 12,2 13,9 15,8 18,1 18,9 24,1 26,2 30,5 32,9 35,6 35,9 37,8 - sensitive, kw 7,0 7,0 9,9 11,0 11,8 15,8 16,4 17,9 22,2 24,7 26,2 31,7 32,0 33,1 38,4 Abs. power kw 2,0 2,0 2,9 2,9 3,8 3,6 5,2 5,3 6,8 7,0 8,2 8,3 10,2 10,3 9,9 Airflow, m3/h 1.830 2.360 2.360 3.230 3.230 4.960 4.950 5.780 5.780 7.260 7.260 9.880 9.880 9.880 11.700 S.P.L.: db (A): UK/OK 45/46 47/48 47/48 48/50 48/50 50/53 51/54 50/53 52/56 52/55 52/55 52/57 52/57 58/60 54/59 Characteristics referring to: Refrigerant R 407C; condensing temp. 45 C; inlet air temp. 24 C, 50% R.H., Static pressure 30 Pa S.P.L. at 2 mt in free field with ducted air discharge. OKW / UKW models with incorporated water-cooled condenser 31-L 31-H 41-L 41-H 51-L 51-H 71-L 71-H 81-L 81-H 101-L 101-H 131-L 131-2L 131-H Cooling cap. total, kw 8,4 9,3 11,3 12,6 14,5 16,3 20,2 19,3 24,8 27,0 32,4 34,4 37,8 36,7 39,8 - sensitive, kw 7,3 7,3 8,3 11,4 12,3 16,1 17,5 19,0 22,5 25,1 27,0 32,0 33,5 34,0 37,3 Abs. power kw 1,8 1,8 2,7 2,7 3,4 3,4 5,0 5,2 6,5 6,7 8,0 8,1 9,9 10,0 9,7 Airflow, m3/h 1.830 2.360 2.360 3.230 3.230 4.960 4.960 5.780 5.780 7.260 7.260 9.880 9.880 9.880 11.700 S.P.L.: db (A) UK/OK 45/46 47/48 47/48 48/50 48/50 50/53 51/54 50/53 52/55 52/55 51/56 52/57 52/57 58/60 54/59 Characteristics referring to: Refrigerant R 407C; condensing temp.40 C, water in temp. 30 C; air temp. 24 C, 50% R.H., Static pressure 30 Pa S.P.L. at 2 mt in free field with ducted air discharge. Mod Puiss. sensib Puissa Débit N.S.: d OKE / UKE models to be matched to remote condensing unit 31 41 51 71 81 101 131 151 Cooling cap. total, kw 9,8 11,4 14,3 22,5 29,7 38,5 31,2 57,3 - sensitive, kw 7,6 9,8 11,9 18,9 22,4 30,3 31,7 45,2 Airflow, m3/h 1.830 2.360 3.230 4.960 5.780 7.250 9.880 11.710 S.P.L.: db (A) UK/OK 44/45 46/47 46/48 49/52 49/52 51/54 53/56 55/58 Characteristics referring to: Refrigerant R 407C; evaporation temperature: 4.2 C; air temp. 24 C; 50% R.H., Static pressure 30Pa S.P.L. at 2 mt in free field with ducted air discharge. OKU / UKU models with chilled water coil 44 46 54 56 74 76 84 86 104 Cooling cap. total, kw 8,0 10,7 15,4 17,5 18,6 20,7 28,8 32,3 39,4 - sensitive, kw 7,7 8,6 13,1 14,0 16,4 17,8 23,2 26,0 31,0 Airflow, m3/h 2.420 2.360 3.300 3.230 4.960 4.750 5.780 5.650 7.260 S.P.L. db (A) UK/OK 44/45 44/45 45/48 45/48 49/52 49/52 48/52 48/52 51/54 Characteristics referring to: Chilled water temp. 7/12 C; inlet air temp. 24 C, 50% R.H. Static pressure 30 Pa S.P.L. at 2 mt in free field with ducted air discharge. Note: The above performances do not consider the power absorbed by the fan, which must be added to the thermal load of the system. Dimensions and weights OKA /UKA /OKW/ UKW models, dimensions in mm 31-L 31-H 41-L 41-H 51-L 51-H 71-L 71-H 81-L 81-H 101-L 101-H 131-L 131-2L 131-H Width 750 750 750 750 750 750 750 900 900 1.190 1.190 1.460 1.460 1.460 1.720 Depth 600 600 600 600 600 750 750 850 850 850 850 850 850 850 850 Height 1.960 1.960 1.960 1.960 1.960 1.960 1.960 1.990 1.990 1.990 1.990 1.990 1.990 1.990 1.990 Net weight kg 165 175 195 206 215 265 270 305 315 340 350 400 405 420 450 OKU / UKU models, dimensions in mm 44 46 54 56 74 76 84 86 104 106 Width 750 750 750 750 750 750 900 900 1.190 1.190 Depth 600 600 600 600 750 750 850 850 850 850 Height 1.960 1.960 1.960 1.960 1.960 1.960 1.990 1.990 1.990 1.990 Net weight kg 160 156 180 185 230 240 280 290 330 340 OKE / UKE models, dimensions in mm 41 51 71 81 101 131 151 Width 750 750 750 900 1.190 1.460 1.720 Depth 600 600 750 850 850 850 850 Height 1.960 1.960 1.960 1.990 1.990 1.990 1.990 Net weight kg 150 180 230 290 310 380 420

Series K air conditioners 131-2H 151-L 72-H 102-L 102-H 132-L 132-H 152-L 37,6 47,5 25,8 29,3 32,1 36,9 37,6 47,5 37,6 41,5 24,3 25,7 31,5 33,1 37,6 41,5 12,6 13,8 5,8 7,2 7,2 12,3 12,6 12,9 11.710 11.710 7.260 7.260 9.880 9.880 11.710 11.710 58/60 58/60 51/54 52/55 54/57 58/60 58/60 58/60 Basic models OK - UK / H : high airflow units for central office and computer centre application. OK - UK / L: low airflow units for comfort application. èles 131-2H 151-L 72-H 102-L 102-H 132-L 132-H 152-L Frigorif. totale, kw 38,2 48,1 25,9 30,1 32,8 36,9 38,1 48,8 le, kw 38,0 42,0 24,6 26,3 31,8 35,6 37,8 41,9 nce absorbée kw 12,2 13,5 5,6 6,9 7,0 12,0 12,2 12,5 d air m3/h 11.710 11.710 7.260 7.260 9.880 9.880 11.710 11.710 B(A): UK/OK 58/60 58/60 51/54 52/55 54/57 58/60 58/60 58/60 102 132 152 38,5 34,2 57,3 30,3 31,7 45,2 7.260 9.880 11.710 51/54 53/58 55/58 106 134 136 154 156 44,5 56,4 60,8 56,3 62,4 34,9 43,2 48,1 45,2 48,9 7.080 9.880 9.710 11.710 11.430 51/54 53/58 53/58 55/58 55/58 Air discharge OK: up flow air discharge and front or downflow air suction. UK: downflow air discharge and front or up flow air suction. Direct expansion OKA - UKA To be matched to air- or water-cooled remote condenser, with R407C or R22 refrigerant. OKA/TS- UKA/TS Equipped with "two season" system, and to be matched to air- or water-cooled remote condenser, with R407C or R22 refrigerant. OKW - UKW With incorporated water-cooled condenser, with R407C refrigerant. 131-2H 151-L 72-H 102-L 102-H 132-L 132-H 152-L 1.720 1.720 1.190 1.190 1.460 1.460 1.720 1720 850 850 850 850 850 850 850 850 1.990 1.990 1.990 1.990 1.990 1.990 1.990 1.990 485 490 360 370 420 425 485 490 134 136 154 156 1.460 1.460 1.720 1.720 850 850 850 850 1.990 1.990 1.990 1.990 350 395 450 460 102 132 152 1.190 1.460 1.720 850 850 850 1.990 1.990 1.990 290 300 400 OKA/FC-UKW/FC Equipped with "Free cooling" system and incorporated water-cooled condenser, with R407C refrigerant. OKE-UKE To be matched to remote condensing unit, with R407C refrigerant. Chilled water OKU - UKU With chilled water coil, to be matched to a remote water chiller.

76210207A.0202 TECNAIR LB S.r.l. 21040 Uboldo - Varese - Italy Via Caduti della Liberazione, 53 Phone 0039 02 9699111 Fax 0039 02 96781570 E-mail: sales@tecnairlb.it www.tecnairlb.it