Installation & User Manual DURAUTO. Domestic Gas Detector

Similar documents
LINEAR HEAT DETECTION CABLE DURÁN-SAFE

LINEAR HEAT DETECTION CABLE DURÁN-SAFE

(CH 4 ) METHANE GAS DETECTOR AE09/GM, AE09/GM-12, AE09/GM-24

NG-9B NATURAL GAS ALARM

Installation & User Manual

169MHz Telecare Devices Gas & Carbon Monoxide Detector

COSTER. Code Internal Alarm Pre-alarm Suitable sensor threshold threshold external sensor

User and Installation manual

169MHz Telecare Devices. Gas Detector

GAS LEAK DETECTORS FOR METHANE AND LPG P11 - P12

A series of technical features make this gas detector extremely versatile, reliable, accurate, and safe.

ModBus DE-1 INSTALLATION AND USER MANUAL

Carbon monoxide household alarm. DURAN ELECTRONICA. Tomás Bretón 50, Madrid, Spain

GAS LEAK DETECTORS FOR METHANE AND LPG P11 - P12

Gas Safety Products. Installation, operating and maintenance. Merlin Gas Detectors. Merlin Gas Detectors. Rev: 09 Date: Product Data Sheet

SENSIT HXG-2d. SENSIT TECHNOLOGIES 851 Transport Drive Valparaiso, IN Phone: (219) Fax: (219)

INSTRUCTIONS AND WARRANTY

Flammable gases Detectors. Model DAX 03F DAX 03F- C DAX 03F- H. Note for installation, use and maintenance. Version 1.2

FLAMMABLE GAS DETECTOR DAX 3F-C INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS. DAX3FC_MAN01_EN.indd Ver. V1R2

LPG STATION CONTROL PANEL - USERS MANUAL EUROPUMP. Document No : LCPUSM.02 First Release : Revision : 00

SENSIT HXG-2d Combustible Gas Detector

INSTRUCTIONS AND WARRANTY

KAE Gas Alarm Operation Manual

Instruction Manual. Electronic gas and smoke detector GRM

FUNCTIONAL SAFETY MANUAL

VENTILATION FAN WITH LED LIGHT AND HEATER MODEL RAD110LED

Manual Power relay SR853

Gas leak detection system. for heating rooms and similar environments. Description. Sensor for methane gas IP44. Sensor for LPG gas IP44

TECHNICAL CATALOGUE GAS LEAK DETECTOR AND SOLENOID SAFETY VALVES

GAS MONITOR Model Model

Model LP USER S MANUAL AND INSTALLATION INSTRUCTIONS

II 2 G. SENSIT HXG-2d. Ex ib IIB T3 IP20. Suitable for combustible gases such as Methane, Butane, Propane and Natural Gas MADE IN USA

Knowledge Objectives (2 of 2) Fuel Gas Systems. Skills Objectives. Introduction. Fuel Gas Systems (1 of 6) 12/20/2013

Gas Fire Patio Heater Lhotse-817

Operating Manual MS220KA and MSR220KA

STAINLESS STEEL FLAMMABLE GAS DETECTOR DAX 3F-I INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS. DAX3FI_MAN01_EN Ver. V1R2

Charlotte Building, 17 Gresse Street, London W1T 1QL

Gas Safety Products. Installation, operating and maintenance. Merlin Gas Detectors. Read these instructions carefully before operating or servicing.

Cooker Hood LA-72-CAN.

User and maintenance manual

WELDING, CUTTING, AND BRAZING SAFETY PROGRAM

Laser Distance Sensor Type M Analog-Output

Fire Safety Guide. Emergency Numbers:

GENERAL PROCEDURES TO FOLLOW IN CASE OF EMERGENCY SAFETY RULES TO PREVENT FIRES

INSTRUCTIONS AND WARRANTY

USE AND INSTALLATION HANDBOOK

FUNCTIONAL SAFETY MANUAL. Gassonic Observer-H and Observer-i Ultrasonic Gas Leak Detector

INSTRUCTIONS AND WARRANTY

Gas Fire Patio Heater Q9

COMBUSTIBLE GAS LEAK DETECTOR PEN

Installation and Operating Instructions. Models: T4-12LOW-9IS-1

Process Control PIP PCEA001 Fixed Gas Detection Guidelines

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2017/09) en

OPERATION & MAINTENANCE MANUAL

Ceiling-Mounted Motion Detector. 752/CD, 752/CP, 752/CU and 752/Cx180. Installation Instructions

CHCO Double Gas Detector

Safety Siren. Owner's Manual. Family Safety Products Inc. Carbon Monoxide, Propane & Methane. Model Number HS80004 HS80104 HS80204 HS80504 DETECTOR

v1.0.0 POWER SUPPLIES 2016

Propane Fume Detection System With Solenoid Valve Control

GB User and maintenance manual

Manual de instrucciones. Bedienungsanleitung. Instruction Manual. Manuel d'instructions. Manual de Instruções

Installation and Operating Instructions MODEL: MSE46W

EXPLOSION-COUNTERACTING SYSTEM «UDAR-KB» Installation Guide

Fire Safety Guide. Emergency Number:

Manual de Instrucciones Campanas Extractoras ND.3. Bedienungsanleitung Dunstabzugshauben ND.3. Instructions Manual Kitchen Hoods ND.

READ AND SAVE THESE INSTRUCTIONS GENERAL SAFETY INFORMATION

TIH 300 S / TIH 400 S / TIH 500 S / TIH 700 S / TIH 900 S / TIH 1100 S

INSTALLATION AND USER S MANUAL COOKER HOOD RS-600/A-S

Propane Fume Detection System

Vanguard. Toxic & combustible gas detector

Technical documentation WATER HEATED AIR CURTAIN MODELS: REVENTON GROUP AERIS 100WN-1P REVENTON GROUP AERIS 150WN-1P REVENTON GROUP AERIS 200WN-1P

IMPORTANT SAFETY INSTRUCTIONS DANGER: WARNING:

FUNCTIONAL SAFETY MANUAL

testo 316-EX gas leak detector Instruction manual

INSTRUCTIONS AND WARRANTY

Propane Fume Detection System With Solenoid Valve Control

Stainless Steel Chimney Extractor

I n s t r u c t i o n m a n u a l f o r b u i l t - i n h o o d. Model code: BORA600

JUMBO INDIRECT FIRED DIESEL HEATER OPERATING INSTRUCTIONS

Stainless Steel Chimney Extractor

ANNEALING FURNACE MODEL 414 User Maintenance Manual/Handbook

KAB Gas Alarm Operation Manual

INSTALLATION AND OPERATION MANUAL GAS SKILLETS MODELS: GTS-30 GTS-40

ZC450-IB-09/13-01 US. Instruction Booklet. Zonecheck 450

Autronica Fire and Security AS ID:

Stainless Steel and Glass Angled Extractor

FIRE SAFETY FOR PRE-SCHOOLS AND CHILDCARE FACILITIES GENERAL GUIDANCE COUNTY COMMITTEE LIMERICK CHILDCARE

Manual de Instrucciones Campanas Extractoras NC. Bedienungsanleitung Dunstabzugshauben NC. Instructions Manual Kitchen Hoods NC

Copying contents of this booklet or handing over to third party is strictly forbidden without written permission from Detector Oy.

INSTRUCTION MANUAL. Full Size Gas Convection Oven

Propane Flame Projector Safety instructions and operating manual

VENTILATION FAN / LED LIGHT / LED NIGHT LIGHT

OWNER S MANUAL FOR ELECTRIC FRYERS. Model Numbers PARAFRYER (240V) ELECTRIC FRYER

Glass Chimney Hood. Installation & User Instructions Please keep for future reference

2010 Fire Log Fire Log. Annual Fire Safety Report

Fire Safety Management Plan. Qube 90, Whitfield Street, W1T 4EZ. Fire Safety Management Plan & Evacuation Procedures

Installation Instructions Use and Care Guide Instructions d installation Mode d emploi et d entretien

USER MANUAL. Cooker Hood ZHG51250GA

WHAT TO DO IN AN EMERGENCY : CRANS-MONTANA COMMUNES

TECHNOSKLO Ltd. Držkov

Transcription:

Installation & User Manual DURAUTO Domestic Gas Detector

1. PRESENTATION DURAUTO is a microprocessed wall mounted detector available in 12V CC/ 230V AC and 2 different versions: Natural Gas and Butane/ Propane. It is provided of optical/acoustic alarm and a relay that permits to activate an extractor or any other electromechanical element. 2. INSTALLATION Warning: Remember that DURAUTO will look after for your safety, therefore, it must be installed by a competent person. Be advised for an authorised installer. Remember that the equipment is just indicated for domestic use: DO NOT INSTALL IT IN OTHER TYPE OF AREAS. LOCATION DURAUTO -Butane/Propane Gas-: at 30 cm from the floor. DURAUTO -Methane/Natural Gas-: at 30 cm from the ceiling. Do not install the equipment lower than 1.5 m -in vertical planeover cooking appliances, over the sink or in any outside locations. Do not install it in places with excessive humidity. Do not install it near doors and/ or windows, behind curtains or at any place where it can be covered by any object. Avoid places with airflows or adjacent to extractor fans. Do not install the equipment close to fryers or places where the grease can damage it.

MOUNTING Verify the power supply in the packaging and label, located in the back of the equipment, and connect it -12V or 230V-. After connecting the apparatus, the alarms will go off stopping after a few seconds when the sensor get the balance right. Do not drill holes in the box. 3. TECHNICAL CHARACTERISTICS SENSOR SENSOR LIFE Multi-layer Semiconductor SMD. 5 years CO, 7 years Exp approx. RESOLUTION +/-2% L.E.L. * ALARM LEVEL 20% L.E.L.* ALARM SOUND 70 db PROTECTED SURFACE 20 m 2 MEASUREMENT RANGE from 0 to 100% L.E.L.* -ajusted to 20%- VOLTAGE 230V AC 50 Hz +/-10% or 12 V CC +/-20% CONSUMPTION 1 W 230V / 175 ma 12V approx. WEIGHT -gr- 160 DIMENSIONS -mm- 120 x 65 x 41 * Lower explosive limit

4. CONNECTION The outputs of several DURAUTO can be connected as follows: -parallel connection- depending on the power supply of the lamp-siren ventilator-electrovalve, etc. maneouvre. 5. IN CASE OF ALARM If the alarm of the DURAUTO for explosive gases goes off, keep calm and follow these recomendations: Do not switch on/ off any light or electrical apparatus. Do not use a telephone where the presence of gas is suspected. Turn off all gas appliances -just in case it is not programmed as the equipment acting-. Open doors and windows to increase ventilation. Vacate the premises until the alarms stop. Notify the event to the gas emergency service and to the gas supplier to proceed to the installationchecking

6. RECOMMENDATIONS Do not manipulate the apparatus while functioning or connected, since it can exist danger of electrical shock. Do not hit the equipment. Do not use near the equipment: enamel paints, dissolvents, cleaning or paints. To clean the equipment use just a cloth dampened with water. Even the equipment has been rigorously calibrated at factory, we recommend to check it periodically as follows: Bring a lighter to the detector and give off the gas without burning the flames. The red pilot will light on and an acoustic alarm will be activated. Take the lighter away and the alarms will stop in a few seconds.

7. GARANTÍA DURAN ELECTRONICA guarantees that DURAUTO has been manufactured subject to strict quality controls. DURAUTO is guaranteed against any manufacturing defect for 2 years from the date of purchase. If during this period of time any anomaly is detected, please advise your supplier or installer. This guarantee will only be valid if the equipment has been installed by a competent person and following the specifications in this manual. Negligent use or installation will exempt DURAN ELECTRONICA from its responsibilities for damage caused to property and/ or people and from the fulfilment of the terms of this guarantee. The guarantee does not cover: Installations, periodical checks and maintenance. Repairs caused by improper handling, inappropriate use, negligence, overload, insufficient power supply or neglecting the equipment, voltage shorts, defective installations and other external causes. Repairs or adjustments carried out by personnel not authorised by DURAN ELECTRONICA. The equipment transport costs. DURAN ELECTRONICA reserves the right to carry out improvements or to include modifications to this equipment without prior notice.

I-mandurautoEXP-v01 c/ Tomás Bretón, 50 28045 MADRID, Spain Tel: +34 91 528 93 75 Fax +34 91 527 58 19 duran@duranelectronica.com www.duranelectronica.com