M Series Fan Filter Units

Similar documents
F116 (Series 16000) Self-Contained Ductable Commercial Air Cleaner

Operating Instructions & Parts Manual Models 99533, 99532

M-11 Series. Installation and Service Manual

Model CAC 500M Media Air Cleaner

Operating Instructions & Parts Manual. Silent Low-Profile Ceiling Fans. Models 3DPE2A, 3DPE3A, 1UBH6B, 1UBH7B, 1UBH8A, 5AE68B, 5AE69A

User s Manual and Operating Instructions

MN908 No. 282C Replaces 282B LB7013

READ AND SAVE THESE INSTRUCTIONS. Air Boss Model T5200 Custom Packaged Electronic Air Cleaner. TRION

F114 and F115 Ceiling Surface Mounted Media Air Cleaners

Insulated Ventilators. Operating Instructions & Parts Manual

USER S OPERATING AND INSTRUCTION MANUAL

MODEL CDB8 INSTALLATION INSTRUCTIONS

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

CELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual. CELDEK Evaporative Cooler

DBF 4XL Dryer Booster Fans

Hawkins 44 in Ceiling Fan Owner s Manual. Hawkins Ventilador de Techo de 1,12 m Manual del Propietario

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

Parts and Service Manual BURNISHER MODEL: MR , MR , MR , MR

THE BARCLAY HUGGER CEILING FAN INSTALLATION INSTRUCTIONS

AC6 & AC8 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions

TITAN FLOW CONTROL, INC.

MaxLite LED Round Pendant Highbay Series

ALL WEATHER SL-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER INSTALLATION USE & CARE MANUAL

Instruction Manual. Dogeroo, Super Dogeroo, and Mini Dogeroo

MANUAL 8/12/05. Model BKP TM 100 INSTALLATION, OPERATION & MAINTENANCE. Commercial High Efficiency Heat Pipe Dehumidifier

Installation Manual. Models 99168, 99169, 99170

Warnings 2. Installation Instructions 3. Wiring Instructions 3. Mounting Instructions 4. Replacement Element Installation 5. Replacement Parts 5

Installation & Maintenance Instructions

24 & 30 Quiet Design Oscillating Wall Mount Fan

ADVANTAGE SERIES KXRP28 AIR-TO-AIR HEAT EXCHANGER

Bathroom Exhaust Fan

CAR-MON DUST COLLECTORS SERIES 207, 2410, 3015

INSTALLATION & OPERATING INSTRUCTIONS & PARTS MANUAL

INSTALLATION USE & CARE MANUAL ALL WEATHER SL-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER

Decorative Low Profile Integrated Kit

Rev. E 2013 Pentair Technical Products P/N Distributed by: McLean Parts

KPHE24 SERIES WATER-TO-AIR HEAT EXCHANGER

User s Manual and Operating Instructions

OKB, OKD, & OKH Series

e Bath Fan with Light User s Guide

Roanoke 48 in Ceiling Fan Owner s Manual. Roanoke Ventilador de Techo de 1,22 m Manual del Propietario

WET/DRY VACUUM. QUEST for Continuous Improvement Windsor s Quality Management System is Certified ISO MODEL: T1. Operating Instructions (ENG)

W Model 1RKU2 w/optional Wall mount. Unit Model Weight (Lbs) Kilowatts Volts- Phase Amps Fan Output Heat Output

e Bath Fan with Light User s Guide

Warnings 2. Installation Instructions 3. Wiring Instructions 3. Mounting Instructions 4-5. Replacement Element Installation 5. Replacement Parts 5-6

User s Manual and Operating Instructions

FES - Series Portable Electric Heaters. YES - Series Suspended Electric Heaters CONTENTS

ELECTRIC FIREPLACE HEATER WITH SINGLE GLASS DOOR

KNHE48 SERIES WATER-TO-AIR HEAT EXCHANGER

Integra Family. Operations Manual. Models: Integra TX SS, Integra HD, Integra DS, Integra DS LA, Integra UHS, Machine Name: Serial Number:

e Bath Fan with Light User s Guide

Thank You & Congratulations On Your Purchase of: ARBE Model # SS-206 Table Top Dust Collector

SPACESAVER INSTRUCTION MANUAL WARRANTY CERTIFICATE

installation, operation & Maintenance manual Floor-mounted Induction units acb 30/35

Panel Mounted Heat Exchangers by Dantherm, Inc.

Static Pressure Alarm For Hazardous Location Fume Hoods

USER GUIDE. This manual covers the description, cautions, operation and maintenance of Super Vac confined space electric ventilators CONTENTS

FLCH4R Garage and Utility Electric Heater

XT Series Thermostats

92831 TEL: (714) FAX:

MODEL NO CRIMPING AND BEADING MACHINE OPERATION, PARTS & MAINTENANCE MANUAL

Installation, Operation, and Maintenance Manual

The Da-Lite Difference.

Instruction Manual. Nacho Cheese Dispenser and Warmer

KPHE32 SERIES WATER-TO-AIR HEAT EXCHANGER

User s Manual and Operating Instructions

Installation & Maintenance Instructions

VENTILATION FAN. MFG Model : VFB80HLED2/VFB080C4L2 /VFB080C4LED2/ VFB100HLED2/VFB100C4LED1 READ AND SAVE THESE INSTRUCTIONS

KNHE30 SERIES WATER-TO-AIR HEAT EXCHANGER

Air Storm Fans. Air Storm 54 Fiberglass Fan Installation and Operation Manual

Desiccant / Pump Dehumidification System. Model Operating Manual

DEDPV-705, DEDPV-705 Hi Alt Dryer Exhaust Duct Power Ventilator (DEDPV)

OPERATION & MAINTENANCE MANUAL MODEL SC-924A SELF-CONTAINED ELECTRONIC AIR CLEANER IMPORTANT: PLEASE READ MANUAL BEFORE OPERATING UNIT

VSA/VSB & KSA/KSB Series Air Doors

Cat 5 Pro Vacuum OPERATOR S MANUAL

CRV Clean Room Vacuum

(3 plastic wire connectors,blade balancing kit, 2 extra mounting screws #10-32 for outlet box.)

THE DAVENPORT CEILING FAN INSTALLATION INSTRUCTIONS

TQ Series. Electronic Control Pump Instruction Manual. 50Hz. ISO 9001 Certified Walrus Pump Co., Ltd.

Service Parts, Kits and Accessories

RP, GP, XP Pro Series Installation Instructions

Instruction Manual. 36 in. and 42 in. Popcorn Staging Cabinets

WMWLB / WMWFM / WTWLB / WTWFM Series Hydronic Heating Unit

OPERATION & MAINTENANCE MANUAL MODEL SC SELF-CONTAINED ELECTRONIC AIR CLEANER IMPORTANT: PLEASE READ MANUAL BEFORE OPERATING UNIT

INSTALLATION USE & CARE MANUAL ALL WEATHER W-SERIES AND WD-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER

Installation & Maintenance Instructions

MaxLite 4, 6, 8 & 9 LED Architectural & Commercial Downlights

ProAir CR43 INSTRUCTION MANUAL FOR: McLean Thermal Business Park Blvd. N Champlin, MN Tel: Fax:

BESF Box Ventilator. Installation & Operating Manual USA CAN READ AND SAVE THESE INSTRUCTIONS

THE ALTON CEILING FAN INSTALLATION INSTRUCTIONS

INSTALLATION, OPERATION AND MAINTENANCE

CLIMAGUARD Air-to-Air Outdoor Heat Exchangers INSTRUCTION MANUAL. Rev. H 2015 Pentair Equipment Protection P/N

THE VALOR CEILING FAN INSTALLATION INSTRUCTIONS

15-Year Limited Warranty

Easy installation in both new construction and retrofit. ZB90C ZB110C X2 Multi-Speed Ventilation Fan INSTALLATION GUIDE

INSTALLATION INSTRUCTIONS FOR DUCTED WHOLE HOUSE FANS

FAN POWERED VAV TERMINALS

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

VENTILATION FAN / LED LIGHT

IMPORTANT INFORMATION - PLEASE READ CAREFULLY

Transcription:

M Series Fan Filter Units Product Specifications... 2 Safety Instructions... 3 Receiving and Unpacking... 3 Pre-Installation Instructions... 3-4 Installation Instructions... 4 Electrical Installation Instructions... 5 Operation Instructions... 6 Troubleshooting Guide and PM Instructions... 7 When to Change the HEPA or ULPA Filter... 8 Wiring Diagram... 9 Warranty... 10

Motor Data Motor Volt. HZ Amps Start-Up Amps Low Med High Low Med High 1/5 115 60 1.45 1.95 2.85 1.70 2.60 5.0 HP 1/5 HP 277 60.52.71 1.1.60.85 1.5 (1) Line voltages can affect actual start-up amperage (2) Use standard NEC tables for sizing circuits M Series Filter Data: The HEPA Filter is designed for 90 FPM average face velocity @ initial 0.47 w.g. and has a rated efficiency of 99.99% @ 0.3 micron or larger. Optional Access Port: This port is located in the center of the filter element face and is used for introducing an upstream challenge or measuring static pressure. Air Flow: 400 to 750 CFM Range for a 2 x 4 unit and 250 to 400 CFM Range for a 2 x 2 unit. At 90 FPM, CFM is nominal 632 on a 2 x 4 and 300 on a 2 x 2 unit. Ceiling Size: All 2 x 4 models are designed to fit a nominal 2 x 4 ceiling grid with a 22.5 x 46.5 standard opening Sound Level: 50-52 dba with less than 45 dba of ambient sound @ 90 FPM measured 30 from face of filter.

Safety Instructions Before servicing or cleaning this unit you need to switch the power off at the service panel, and then lock the service disconnecting means to prevent the power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. The M Series Fan Filter Units are suitable for commercial and industrial use only. They are designed for suspended installation or installation in T-Grid Ceiling Systems for Vertical Flow. Do not place anything on top of the units or restrict the flow of air into the unit, and never expose them to water, ice, snow, or extensive moisture. Receiving and Unpacking All shipments are FOB Ship Point. This means once goods are picked up and signed for by the driver, they are the responsibility of the freight company. When the shipment is delivered and signed for by your receiving personnel, the ownership and responsibility is transferred to the receiving company. Bennett & Bennett Inc. inspects each product before packaging and does not ship damaged goods. Inspect the incoming shipment with the freight carrier driver present. Note any suspected damage on the receiving papers and immediately inspect the damaged carton(s). Note damages on the receiving documents and file a freight claim with the transportation company. Bennett & Bennett does not take responsibility for damages caused by the freight company. If damage is discovered after the carton is opened, it is the buyer s/receiver s responsibility to file a freight claim. Keep all incoming cartons and the product for inspection. Do not send back to Bennett & Bennett. Pre-Installation Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction. M Series Fan Filter Units operate on 115 Volts, 277 volts at 60 Hz. Check the label on the front of the unit for voltage, current and frequency of operation. Verify the rating of the branch circuit wiring prior to installation 3

and electrical connection to the unit. Certain models are provided with an optional flexible power cord with plug. Do not use any type of adapter that will allow the unit to be plugged into an outlet that is not grounded. Do not plug the unit into an outlet that is controlled by an on/off wall switch or by a facility house lighting control switch. Caution: To reduce the risk of injury to persons, install the unit at least 7 feet above grade or in ceiling. Installation Instructions HEPA and ULPA filter media is fragile and can be damaged easily. Special precautions must be taken during unpacking and installation of M Series Fan Filter Units to avoid damage to the filter media. TOUCH ONLY THE FRAME AND DO NOT PLACE HANDS OR ANY OTHER OBJECTS ON THE FILTER SURFACE. Commercially available 1 or 1-1/2 T-Grid suspended ceiling systems are not designed to support the weight of any fan powered filter units. Bennett & Bennett supplies 2 T-Grid systems for softwall and hardwall cleanrooms that do provide the support necessary for direct mounting of M Series Filter Fan Units. If 2 T-Grid system is not installed, it is mandatory that M Series Fan Filter Units be suspended independently from these suspended ceilings Mechanical installation of Suspended Vertical Flow Units: M Series Fan Filter Units are equipped with attachment points to make the installation hanging process easy. Units may be supported with flexible or rigid hangers. Use at least 12-gauge hanging wire for the equivalent light chain or cable on each corner to support the unit. Mechanical Installation of Units in 2 T-Grid Systems: Install 2 T-Grid system in accordance with site plan and manufacturers instructions. Install seal gaskets (if provided) in pre-designated locations. Carefully place M Series Fan Filter Unit into the grid opening taking care to not damage the filter media while handling the units. 4

Electrical Installation Provision of electrical branch circuit supply to the appropriate location within close proximity to the M Series Fan Filter Units is the responsibility of the customer s electrical installer. If local or national electrical codes or the customer s installation specifications require the provision of metal conduit directly to the unit it is recommended that UL Listed flexible metal conduit be provided. M Series Fan Filter Units may be supplied with optional flexible power cords with grounded plug, optional 2 x 4 or 4 x 4 metallic wiring boxes with covers, with or without a power switch mounted in the wiring box or optionally within the pre-filter frame housing. When a power switch is provided, field connections are to be made directly to the open supply of terminals of the switch. When a power switch is not provided, field connections are to be made to the non-connected pigtail leads within the metallic wiring box or pre-filter frame. CAUTION: When making field wiring connections within the Pre-Filter Frame, make sure that all field installed wiring is routed away from moving motor and fan parts and is secured in place to prevent inadvertent damage to wires. Start-up Check List-Before Applying Power: Check the voltage on the Name Plate and verify that the power supplied to the unit is the same as that listed on the Name Plate. Remove the Pre-Filter and determine if the fan is free to rotate and has not been misaligned during shipment or installation. Check nuts, bolts, screws, and electrical connections for tightness. CAUTION: If the unit is provided with a square perforated metal barrier over the opening to the Pre-Filter Frame, it must be installed again prior to application of power and startup of the Fan Filter Units. Apply power and check that the wheel is rotating in the correct direction. Looking through the Pre-Filter Frame the fan must be rotating in a clockwise direction. 5

Operation Instructions M Series Fan Filter Units are self-contained, low profile, electric powered, motor-fan driven HEPA or ULPA Filter, air filtering appliances. The units are heavy-duty units suitable for many industrial / commercial applications where clean air is needed. This is accomplished by maintaining a flow of filtered air to remove airborne particles within an enclosed room or chamber. Where manufacturing and assembly processes require Federal Standard 209 or ISO Classification clean rooms, multiple M Series Fan Filter Units can provide a sufficient number of filtered air changes to maintain a positive pressure of clean air within the controlled environment. Because of the unique variety of sizes and options offered, M Series Filter Fan Units can be incorporated into many different areas such as Softwall Cleanrooms, new Hardwall Cleanroom designs, and facility upgrades over conveyors or free standing machinery. They may also be incorporated into custom workbench constructions providing concentrated filtered air to meet critical clean air process requirements. Method of Operation Unfiltered air is drawn into the air inlet at the top of the unit through an optional 20 x 20 Pre-Filter. This air is puled through the motor / blower assembly into a plenum designed to evenly distribute air over and through the entire receiving surface of the HEPA Filter. Thus, M Series Fan Filter Units efficiently and quietly deliver the desired volume of cleaned air to the controlled environment. The volume of air delivered can be adjusted by means of a factory installed 3-speed switch. 6

Troubleshooting Guide: Problem: Blower Doesn t Run Possible Solution: 1. Make sure the unit is properly connected to the power source. 2. Make sure the 3-speed switch is in the high, medium, or low position. 3. Verify that there is power running to the outlet. 4. Check the capacitor for loose connection. Problem: Blower is running, but no or very little air flow is being generated: Possible Solution: 1. Make sure the blower is running clockwise as viewed through the Pre-Filter Frame and Blower Opening. 2. Pre-Filter is dirty and should be replaced. 3. HEPA Filter is dirty and should be replaced. Preventive Maintenance (PM) Instructions To ensure optimum safe performance and maximum product life you should have a preventative maintenance program. 1. Inspect the Pre-Filter, HEPA or ULPA Filter after the first three (3) months of operation. Based on the findings, schedule periodic inspections and maintenance for changing the Pre-Filter and the HEPA or ULPA Filters. 2. Pre-Filters should be changed at least every six ( 6) months. 3. Cleaning the fan wheel is required to ensure smooth quiet operation. Periodic cleaning of all fan equipment is strongly recommended because dirt accumulation on the propeller can cause vibration increases stress and load on motor bearings. 4. Order replacement filters from Bennett & Bennett on the web or contact us toll free at (888) 423-6638 7

When to Change the HEPA or ULPA Filter Static pressure can be measured with a Magnehelic gauge or manometer. If the resistance to pressure drops across the filter at twice the original resistance it is time to change the filter. Tools Required: 1. Power driver, 1/4 socket bit 2. Standard slotted screw driver How to Change the HEPA or ULPA Filter: 1. Remove the M Series Fan Filter Unit from th ceiling, and place it on a solid surface. 2. Use a power driver and 1/4 socket bit or, Phillips head screwdriver, remove twelve Self-Piercing Screws located on the plenum flange. 3. Separate the plenum hood assembly from filter. 4. Clean the plenum flange surface. 5. Place plenum hood assembly on top of the replacement filter. 6. Install all Self-Piercing Screws and place the M Series unit back into the ceiling. 8

Wiring Instructions 9

Bennett & Bennett Product Warranty Bennett & Bennett warrants this equipment to be free from defects in material and workmanship for a period of one (1) year from the date of shipment. No other warranty is herein expressed and none shall be implied. If failure appears within one (1) year from date of purchase, the buyer must notify Bennett & Bennett immediately. Documentary proof of length of service (which shall include date of purchase) must be furnished to Bennett & Bennett if the date of manufacture was more than one (1) year prior to the date of alleged failure. Defective product may be delivered freight prepaid to the nearest Bennett & Bennett authorized location. Bennett & Bennett shall, at its option, correct the defect, or supply a replacement. The liability of Bennett & Bennett shall not in any case exceed either the cost of correcting defects in the product or supplying a replacement for that, whichever shall be less, and upon the expiration of one (1) year from the date of shipping by Bennett & Bennett all such liability shall terminate. Bennett & Bennett is not responsible for damage to the product due to abuse, improper installation, use other than for which it was sold, or through operation above rated load, either intentionally or otherwise of any party. Under no circumstances will Bennett & Bennett be responsible for any freight (in or out), installation, or removal costs. The foregoing warranty is in lieu of all other warranties, express or implied, with respect to the product, including any implied or statutory warranty of merchantability or fitness for purpose. Bennett & Bennett shall not be liable by virtue of this warranty, or otherwise, for any consequential, incidental or special loss or damage resulting from the use or loss of use of the product. 10