User Manual for model RK 18 RK 25 RK 34 CE 0694 RK 18_25_34 - RAD - ING - MAN.UT A - DIGITECH 2 - REGNO UNITO - EXTRAHEAT - CBD

Similar documents
User Manual for model

User Manual RBS 24. for model CE series ENERGY. Wall mounted instantaneous combi boiler room sealed chamber

User Manual for model

User Manual FLOWMAX-90. for model. Condensing water heater 85,000 BTU. Installation, operating, commissioning and maintenance instructions.

E-COMBI EVO E-SYSTEM EVO

USERS MANUAL FOR GAS BOILERS

USERS GUIDE. Esprit eco 24, 30. For installation guide see reverse of book

System s30. User Guide FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS SYSTEM BOILER

E-Combi One E-System ONE

USER GUIDE VOGUE MAX SYSTEM

GB24 & GB30. User Manual

i 24, i 30, i 35 combination boilers USER GUIDE For Installation Guide see reverse of book UIN A05 October 2017

USER GUIDE LOGIC HEAT H

USER GUIDE VOGUE COMBI GEN2 C26 C32 C40

24/30/38. E-Combi. CONDENSING WALL HUNG COMBINATION BOILER G.C.N : (24 kw) G.C.N : (30 kw) G.C.N : (38 kw)

USERS GUIDE 24, 30. For installation guide see reverse of book

The guarantee on this appliance is valid for 12 months from the first day of installation.

/2010 US/CA

WHE 2.24 / WHE 2.24 FF

Combi C30 & C35. User Guide FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS COMBINATION BOILER

Residential Gas Condensing Boiler Greenstar ZBR16/21/28/35/42-3A... ZWB28/35/42-3A...

Logic+ Combi

User's Instructions. Alpha CB50

Aqua Balance. AquaBalance TM CONTROL MODULE QUICK START GUIDE LEGEND

USERS GUIDE. LOGIC+ Combi 24, 30, 35

RKA 24.8_24_28_34 - RAD - ING - MAN.INST A - DIGITECH 2 - REGNO UNITO - EXTRAHEAT - CBD

User's Instructions. Alpha CD25X/28X. Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boilers

User's Instructions. Alpha CD24C/32C. Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boilers

INSTALLATION AND MANINTENANCE INSTRUCTIONS

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2017/09) en

TABLE OF CONTENTS. IMPORTANT Please read this manual carefully.

For the owner. Operating manual. ecotec plus 937. Gas condensing storage combination boiler VUI

CONTROL CABINET for cascade boiler systems

Residential Gas Condensing Boiler Greenstar combi 100 p / 151 p ZWB28-3A... ZWB42-3A...

ir-range 8G /03.15 Changes reserved.

Baxi Megaflo System HE IE Range. User s Operating Instructions & Important Warranty Information. Gas Fired Wall Mounted Condensing Boiler

Maximiser SE. USER S INSTRUCTIONS Natural gas only INSTALLER: TELEPHONE:

User s Information Manual

Operating instructions

PLEASE LEAVE THIS INSTRUCTION WITH THE USER ECOMFORT PLUS 25 HE. User instructions

Operating instructions

Open Vented Condensing Boilers

USER INSTRUCTIONS & CUSTOMER CARE GUIDE Si II SERIES

End User Manual ACO 35 MFFI COMBI

User manual. Logano GC 124 II. Gas boiler

INSTALLATION, AND MAINTENANCE MANUAL FOR GAS FIRED, ONLY HEATING WALL-HUNG BOILERS (SYSTEM BOILERS)

Service & Trouble Shooting Manual

TAHITI CONDENSING KR 55 - KR 85

Combi Eco Elite Range. User s Guide and Important Warranty Information


FORMAT DGT HE. User instructions. Please read the Important Notice within this guide regarding your boiler warranty

Installation and Servicing Instructions RHA 28. Gas Fired, Condensing Boilers with Storage Cylinder CE 0694 SEDBUK BAND B TG05A062.

USER'S INFORMATION MANUAL

INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS BG 2000-S (V13) RU PL DE IT ES NL EN 1 662Y0600 A

USER'S INFORMATION MANUAL

PLEASE LEAVE THIS INSTRUCTION WITH THE USER. Ecomfort 30 HE. User instructions

User Guide and Important Warranty Information. Promax System HE Plus A Range. Condensing System Boiler

Performa 24 Eco HE. User Guide and Important Warranty Information. Condensing Combination Boiler

Thermo 230 / 231 / 300 / 301 / Troubleshooting

CE 0694 RADIANT BRUCIATORI S.p.A. Montelabbate (PU) ITALY

Format System 25 HE. User instructions. Please read the Important Notice within this guide regarding your boiler warranty

iheat 25c iheat 30c iheat 35c

IE Instructions and warning book CRONO 7. Weekly digital chronothermostat

Operating instructions

INSTALLATION, USE, AND MAINTENANCE MANUAL FOR GAS FIRED, WALL-HUNG BOILERS WITH DOMESTIC HOT WATER STORAGE CYLINDER

Mikrofill Ethos Condensing combination boiler

Oil TRIANCO. EuroStar Range BURNER DETAILS TRIANCO - OIL BURNER. To be retained by householder

Ultracom 2. sxi. Instructions for Use. 12sxi. 18sxi. 30sxi. High Efficiency Condensing System Boilers. To be left with the user. G.C. No.

JUMBO INDIRECT FIRED DIESEL HEATER OPERATING INSTRUCTIONS

condens Instructions for Use Betacom 2 24 G.C. No Betacom 2 28 G.C. No

USE AND MAINTENANCE. Cm Pelet-set (60-90 kw) TECHNICAL INSTRUCTIONS

A/23 MFFI - A/27 MFFI

LIBRA DUAL INSTALLATION USE AND MAINTENANCE. Italian product. High quality IST 04 C

Operating instructions

TECHNICAL INSTRUCTIONS USE AND MAINTENANCE

SERIES. End User Manual ACO 27 MFFI G.C.N: ACO 32 MFFI G.C.N: ACO 27 RFFI G.C.N: ACO 32 RFFI G.C.

USER'S INFORMATION MANUAL

Wall-hung gas boilers. Instructions for use. English 31/08/05

GENUS HE GENUS HE 24 GENUS HE 30 GENUS HE 38. User Manual. Condensing wall hung system boiler

Operating instructions

Figure 10 or Figure 6

V.lla Pro 5200 R - Cod. M0S Edizione 1H04

BOSCH CONDENS 5000W ZSB18-2A

PROGRAMMABLE 7-DAY THERMOSTAT

Aqua Balance. User s Information Manual. WMB-155C Wall Mount Gas-Fired Combination Boiler Heating and Domestic Hot Water

User s Information Manual

Operating instructions

Servicing manual. 600 Series - 11S / 19S / 24S / 24C. Wall-mounted condensing gas boiler. For trade use

Servicing manual. Wall-mounted condensing gas boiler 600 Series - 11S / 19S / 24S / 24C /2002 GB(EN) For trade use

instructions FAN HEATER HVF3533 Please retain these instructions for future reference

DTG Eco / V130

USER GUIDE. IMAX XTRA EL kW. For Installation Guide see reverse of book

USE AND MAINTENANCE. Cm Pelet-set TECHNICAL INSTRUCTIONS. (14-35 kw) For boilers: EKO-CK P (EKO-CK 20-40) EKO-CKB P (EKO-CKB 20-40)

24CDi, 28CDi & 35CDi II COMBI

Baxi Combi 105 HE. User s Operating Instructions. Gas Fired Wall Mounted Condensing Boiler

NR-20DU. Keep this manual near this remote controller for future reference whenever maintenance or service is required.

Verdi 90 & 120 Ceiling Hood Re-Circulating and Ducted Installation & User Instructions

Planet Super4F.S. User Instructions

Ultracom cxi. Instructions for Use. High Efficiency Condensing System Boilers. To b e l e f t w i t h t h e u s e r.

USER'S INFORMATION MANUAL

Transcription:

User Manual for model RK 18 RK 25 RK 34 Premix condensing boiler User instruction CE 0694 RK 18_25_34 - RAD - ING - MAN.UT - 1104A - DIGITECH 2 - REGNO UNITO - EXTRAHEAT - CBD Technical specification by RADIANT BRUCIATORI S.p.A. Montelabbate (PU) ITALY ENGLISH

BOILER OPERATING INSTRUCTIONS Make sure that the authorised technician who tested the boiler has stamped the guarantee booklet. The installation, first start-up, regulation and maintenance operations must be carried out exclusively by qualified personnel (e.g. Radiant authorised Service Centres). Incorrect installation can cause damage to property and injury to persons or animals, for which the manufacturer will not be held responsible. During the installation, the technician must carry out the following checks: The data on the data plate must correspond to that of the mains supply networks (gas, electricity, water). The boiler must be regulated according to its designed use and performance. The flue gas exhaust and combustion air intake system must be correctly installed and operational. The exhaust gas discharge and ventilation systems must comply with the requirements of national and local standards regardless of whether the boiler is installed indoors, outdoors or in its own cabinet (see section Reference standards. General warnings If there is any doubt as to whether the appliance has been tested by an authorised technician, do not attempt to start it. All maintenance and gas conversion operations MUST BE CARRIED OUT BY PROFESSIONALLY QUALIFIED PERSONNEL, registered in accordance with current legislation. Make sure that the requirements relating to the air intake and ventilation of the room in which the boiler is to be installed have been complied with. The boilers can be installed outdoors in a partially protected location, in accordance with current standards and where the minimum external temperature does not fall below 10 C. The manufacturer will not be held responsible for installation in locations where the temperature falls to below 10 C. The boiler is fitted with an antifreeze system. If the boiler is installed in a location where there is a risk of freezing, the anti-freeze system will only come into operation if the power is on and the gas supply valve is open (the frost protection is active even with the ON/OFF switch in OFF position). The manufacturer will not be held responsible for damage to the boiler caused by non-compliance with this instruction. Should any part of the boiler freeze-up, do not attempt to light it under any circumstances, but instead call the Service Centre immediately. The Benchmark Book is an integral part of an installation. The Benchmark handbook should be filled-in each time a boiler is installed. In addition to checking the combustion, all ordinary and extraordinary maintenance operations must be reported in the booklet together with the name of the person carrying out the maintenance and, where applicable, his company. The appliance s combustion system must be checked every two years. This check includes testing the efficiency of the boiler and must be carried out by authorised personnel possessing the qualifications as required by current law. Do not obstruct the ventilation openings in rooms where there are gas-burning appliances installed (boiler, cooker, etc.). If you smell gas DO NOT ACTIVATE ANY ELECTRIC SWITCHES, TELEPHONES OR ANY OTHER DEVICE THAT MAY GENERATE ELECTRICAL DISCHARGES OR SPARKS. OPEN DOORS AND WINDOWS IMMEDIATELY TO CREATE A CURRENT OF AIR THAT WILL RAPIDLY CLEAR THE ROOM. CLOSE ALL GAS TAPS AND VALVES. CALL FOR PROFESSIONALLY QUALIFIED PERSONNEL. 1

Boiler controls - Control panel LEGEND 1. ON/OFF BUTTON 2. HEATING TEMPERATURE CONTROL KNOB 3. NOT OPERATIVE KNOB. 4. OUTSIDE TEMPERATURE DISPLAY (ONLY WITH OPTIONAL OUTDOOR SENSOR). 5. SERVICE BUTTON. 6. WINTER MODE SELECTION BUTTON. 7. TERMINAL BOARD FOR EXTERNAL WIRING. 8. TEMPERATURE, ERROR CODE AND OPERATING STATUS DISPLAY. 9. TIME CLOCK (optional) 9 8 Fig. 1 1 2 3 4 5 6 7 2

Starting - up the boiler Open the gas Isolation valve located under the boiler. Switch on the boiler by placing the ON/OFF switch (1) in the ON position (see Control panel ). The boiler will light automatically (with the WINTER mode selected and room thermostat connected). 9 8 Check that there are no flashing numbers on the display 8 (see error codes). If code H2O appears on the display 8 this denotes that there is no water in the boiler. Consequently, fill the system as described in section Filling the system. 1 Fig. 1 2 3 4 5 6 7 WINTER mode To switch boiler operation to WINTER mode, press button 6 (see fig. 1). The boiler will only work for the central heating system. The WINTER mode setting of the boiler is signalled by the symbol lit continuously on the control panel. The automatic ignition system will light the burner every time there is a demand for room heating. In this case, the symbol on the control panel will flash. Regulating the heating temperature The heating temperature is regulated by knob 2 (see fig.1). Rotating the knob anticlockwise reduces the temperature. Rotating the knob clockwise increases the temperature. The range of temperature settings for the central heating runs from a minimum of 30 C to a maximum of 80 C, or, in the case of low temperature operation, from a minimum of 25 C to a maximum of 59 C. 3

Topping-up the system with water The water pressure in the central heating circuit must be checked during the entire period of operation of the boiler. In this respect, the reading on the pressure gauge M (see fig. 2), located on the lower part of the boiler, must not be less than 1 bar. If there is insufficient water in the boiler, the code H2O will flash on the display (see Control panel ). To bring the system back up to pressure, open the external filling loop valve (see fig. 3) and use the pressure gauge M (see fig. 2) to check that the system pressure reaches 1 bar and that the code H2O lights up. When the operation is complete, close the fill valve. Diagnostics Error codes: This paragraph contains a list of error codes that the boiler may generate on the display 7 (see Control panel ) together with the relative indications and the operations that the user can carry out to reset the boiler. Fig. 2 CWI HF M OPTIONAL If the problem re-occurs after the following actions have been taken, call an authorised Service Centre. _E01 E01_ Ionisation block Code E01 lit continuously on the display. Fig. 3 12-00710 Check that the gas valve on the boiler and gas meter are open and that there is gas in the mains supply (or in the tank). Switch off then switch on the appliance using switch 1 (see Control panel ) on the control panel. When the error code on the display disappears, the boiler will restart. If the problem persists, Call the Service Centre. _E02 E02_ Safety Thermostat tripped Code E02 lit continuously on the display. Call the Service Centre. _E03 E03_ Flue Gas Thermostat tripped Code E03 lit continuously on the display. Call the Service Centre. _h2o h2o_ Water Pressure Switch tripped Code H2O lit continuously on the display. Check the water pressure in the central heating circuit. The reading on the pressure gauge M (see fig. 2), located on the lower part of the boiler, must not be less than 1 bar. If the pressure is less than 1 bar, top-up the system as described in paragraph Filling the system. The boiler will restart automatically. If the problem persists, Call the Service Centre. 4

_E05 E05_ Heating Sensor malfunction Code E05 lit continuously on the display. Call the Service Centre. _E16 E16_ Electric Fan Malfunction Code E16 lit continuously on the display. Call the Service Centre. _E22 E22_ Parameter programming request Code E22 lit continuously on the display. Call the Service Centre. _E35 E35_ Flame Detection Malfunction Code E35 lit continuously on the display. Call the Service Centre. N.B. If the boiler is to be left unused for a long period of time, the user must do one of the following: Make the boiler safe by disconnecting all the power supplies (electricity and gas), and draining the heating system and the condensate trap. Leave the boiler in standby, leaving the electricity and gas supplies connected and, consequently the anti-freeze function. 5

extraheat Limited Belmayne House Clarkehouse Road Sheffield S10 2LN South Yorkshire Phone Number 0844 3814115 Fax Number 01142 309147 E Mail: radiantboilers@extraheat.co.uk radiantcustomersupport@extraheat.co.uk Website: www.radiant.eu THE TECHNICAL DATA AND MEASUREMENTS ARE PROVIDED FOR INFORMATION PURPOSES ONLY AND ARE NOT BINDING. THE COMPANY RESERVES THE RIGHT TO APPLY VARIATIONS WITHOUT PRIOR NOTIFICATION. NEITHER WILL THE COMPANY BE HELD RESPONSIBLE FOR ANY INACCURACIES IN THIS HANDBOOK DERIVING FROM PRINTING OR TRANSLATION ERRORS. E+OEALL RIGHTS RESERVED. NO PART OF THIS DOCUMENT MAY BE REPRODUCED, MEMORISED IN ANY FILING SYSTEMS OR TRANSMITTED IN ANY FORM WHATSOEVER, INCLUDING ELECTRONIC, MECHANICAL, PHOTOCOPIES, RECORDINGS OR ANY OTHER MEANS WITHOUT THE COMPANY S PRIOR WRITTEN APPROVAL.