SEMCO CHILLED BEAMS INDOOR AIR QUALITY AND ENERGY SAVINGS FANLESS FILTERLESS SPACE CONDITIONING

Similar documents
ENERGY EFFICIENCY WITH SUPERIOR INDOOR AIR QUALITY

CONTROLLED CHILLED BEAM PUMP MODULE

PINNACLE SERIES DEDICATED OUTDOOR AIR SYSTEM ENERGY EFFICIENT DEHUMIDIFICATION

Benefits Offered by Passive Dehumidification Wheel Speed Control

CONTROLLED CHILLED BEAM PUMP MODULE

LYRA » ENERGY EFFICIENT CASSETTE CHILLED BEAM AIR DIFFUSION LYRA

HEALTHCARE SURGERY VENTILATION HUMIDITY CONTROL

EP SERIES PACKAGED ENERGY RECOVERY SYSTEM ENERGY EFFICIENT AIR COMFORT

ASCENDANT CONVENTIONAL COOLING, ACTIVE DESICCANT DEHUMIDIFICATION SYSTEM ASCENDANT LOW DEW POINT EFFICIENT & EFFECTIVE

CHILLED BEAM CASSETTE IQ STAR LYRA

A COMPLETE RANGE OF CHILLED BEAMS FOR COMFORT AND FLEXIBILITY

THE IMPORTANCE OF THE DESICCANT RESULTS OF CROSS-CONTAMINATION TESTING ON DESICCANTS

AIR DIFFUSION A COMPLETE RANGE OF CHILLED BEAMS FOR COMFORT AND FLEXIBILITY CHILLED BEAMS. iq Star Lyra II iq Star Stella Flexicool IQID

iq Star LYRA II chilled beam cassette

HAP e-help. Modeling Induction Beams in HAP v4.8 QB TIP 001

Chilled beams. TRACE 700 incorporates two chilled beam strategies: passive and active.

Modular Active. Chilled. Beams

iq Star LYRA II chilled beam cassette

Halton CPT Passive Chilled Beam

Chilled beams designed for optimum comfort

NOVEMBER 2012 THE EUROPEAN EXPERIENCE

Mechanical System Redesign. Dedicated Outdoor Air System. Design Criteria

HOTEL CHILLED BEAM IQ STAR SILENCIA

Unit heater with accessories

RITE-HITE FANS HVLS FANS A REVOLUTION. IN COST, COMFORT AND DESIGN.

LG VRF Systems. Air Conditioning Technologies

Custom Performance Climate Changer air handlers. Expertly designed and built to meet your specific requirements

ENGINEERING BULLETIN. Overview of Chilled Beam Technology. Purpose. Summary. Theory

VAV CHILLED BEAMS Pi FUNCTION DESIGN GUIDE

Liquid desiccant dehumidification systems. Product guide

NEW AR-L AR-C AND HIGH-CAPACITY LINEAR COOLING PANELS. Higher energy efficiency. Increased thermal comfort

EU Air Handling Units with SEMCO EXCLU-SIEVE

Chilled beam technology overview John Woollett 1, Jonas Åkesson 2 Swegon AB 1,2

Product Data. Features/Benefits. 36CBAC,AE,AF,AH,AQ,AN, PB,PD,PS Series Active and Passive Chilled Beams. 11 to 190 cfm

DADANCO Technical Paper

ADRIATIC VF. Active chilled beam with cooling, heating and ventilation QUICK FACTS

Novel Liquid Desiccant Systems

IDL20e (2 way discharge) IDS60e (4 way discharge) Inffusers. UDI (vertical discharge) Frequently Asked Questions

KLIMA Active Chilled Beams

ClimaFläkt. Chillers and condensing units

Units for suspended ceilings Type DID632

Chilled Beams. Getting a Warmer Reception

RoofPak Applied Rooftop Systems

D-PAC. Digital Precise Air Control System. Functionality Factory Testing Ease of Installation Ease of Maintenance Energy Efficiency

Use. Worth noting. Key figures. Installation. linx industries chilled beams. the beam is mounted on a standard T-support.

IPSUM OPTIMIZATION SYSTEM» DEMAND CONTROLLED VENTILATION OVERVIEW

DAIKIN 17 SERIES SINGLE ZONE INVERTER WALL-MOUNT SYSTEM S. Up to 17 SEER Up to 9.0 HSPF / Up to 11.5 EER HEAT PUMP AND COOLING ONLY

PRODUCTS TAO TAO PRODUCT: ADVANCING THE SCIENCE OF AIR DISTRIBUTION. temperature ambient optimizer. Redefine your comfort zone.

DSS SERIES SINGLE ZONE INVERTER WALL-MOUNT SYSTEMS. Up to 17 SEER Up to 9.0 HSPF / Up to 11.5 EER HEAT PUMP AND COOLING ONLY

The swirl comfort unit is a compact air-conditioning unit providing swirl jet air supply.

Linear Floor Heaters

Swegon PACIFIC. Integrated chilled beam PACIFIC CHILLED BEAM KEY FIGURES

DX Units. Ranging from 15 to 750 tons and 1,000 to 300,000+ CFM

Use. Worth noting. Key figures. Installation. linx industries chilled beams

Waterborne Climate Systems

Active Chilled Beams

UFAD and Displacement Ventilation. Dan Int-Hout, FASHRAE Chief Engineer Krueger Richardson, Texas

APPLICATION GUIDE BEAMS

Active Chilled Beams. Technical Data Bulkhead-Mounted Concealed Model With Horizontal Coil and Auxiliary Drain Pan

Displacement Ventilation

Data Aire LCS TM (Large Ceiling System) R-410A. 6, 8, 10, and 13 ton. ISO 9001 Certified

VH Series B ENVIRO-STAC Vertical Hi-Rise Fan Coil Unit with Enhanced Humidity Control

PFS Single stage axial fan The axial fan for modern boiler plants

ACBH/ACBV ACTIVE CHILLED BEAM INSTALLATION MANUAL. Date: 05/12 Reference # : L-50.

DAIKIN 19 SERIES SINGLE-ZONE HEATING & COOLING SYSTEMS

Data Aire LCS TM (Large Ceiling System) R-407C. 6, 8, 10, and 13 ton. ISO 9001 Certified

DRYAIR Turnkey Dry Room Standards

Chilled Beams in Labs Eliminating Reheat & Saving Energy on a Budget

Primo Hotel. General. Indoor climate units for hotel rooms

RT-OA TM Rooftop Outdoor-Air (DOAS)

Air Conditioning Clinic

LV SERIES SINGLE-ZONE HEATING & COOLING SYSTEMS

Active Chilled Beams. Technical Data Concealed Ceiling Mounted Model With Vertical Coil and Integral Drain Pan

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise VAV Terminal Units Full Spec. Prepared by: Phone Number: Prepared for:

Dehumidifying with Dedicated Outdoor Air

VARIABLE REFRIGERANT FLOW (VRF) FULL LINE CATALOG

ASHRAE Region VI CRC Track III: Session 3 Ventilation Energy Recovery. Steven T. Taylor, PE Principal Taylor Engineering

HVAC DISTRIBUTION and DELIVERY SYSTEMS

Scholar III Unit Ventilator

Designing Energy Efficient Outdoor Air Systems

Selected Laboratory Energy Efficiency Measures

recooler HP EQKR HEAT PUMP

Smoke Control Ducts and Dampers For Single Compartment Applications. Fulfilling new requirements for EN product standards for CE Marking

LV SERIES SINGLE-ZONE HEATING & COOLING SYSTEMS

Heat Recovery Units. Heat Recovery 1

AND WORRY-FREE PERFORMANCE

LENNOX MINI-VRF SYSTEMS. CONNECTING TECHNOLOGY WITH EXPERTISE.

Rooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating

Questions??????? Thank you

Daikin 19 SERIES SINGLE ZONE HEATING & COOLING SYSTEMS

ULTRA HIGH EFFICIENCY CONDENSING BOILERS MILLION BTU/HR

L E N N O X MINI-SPLIT SYSTEMS THE SOLUTION THAT WORKS WHERE OTHERS WON T.

Submittal Data Performance Data Electrical Data

Do All DOAS Configurations Provide the Same Benefits?

PoolPak MPK Series. PoolPak.com. Environmental Control Systems REDUCED FOOTPRINT & WEIGHT COMPARED TO EARLIER GENERATIONS

Rittling Induction Units Catalog

HCU Systems for Industrial Applications. Rob Smith National Accounts Manager March 7, 2011

BTBa. FLUSHLINE Ventilated chilled beam for cooling, heating and ventilation. BTBa

Modular Heating & Ventilating Unit Model IGX-HV

100% Outdoor Air Dehumidification Methods

Transcription:

FANLESS FILTERLESS SPACE CONDITIONING SEMCO CHILLED BEAMS INDOOR AIR QUALITY AND ENERGY SAVINGS

IQHC Active Chilled Beam An intelligently designed active chilled beam that has the highest industry cooling capacity with the lowest air and water pressure drop Eurovent certified performance Lowest pressure high capacity beam By utilizing low pressure coils and slots in lieu of nozzles, true energy savings is realized. SEMCO gives the building automation system the opportunity for the greatest energy turndown by placing the bulk of the cooling capacity on the coil. With SEMCO s beam capacity, the forced primary airflow can be selected for its smallest value, maximizing the reduction of fan horsepower. Reliable operation and long life expectancy DESIGNING FOR PRESSURE OPTIMIZATION The industry of chilled beams generally utilizes fixed nozzles, creating difficulties for design and commissioning with regards to air and pressure. SEMCO s approach is to utilize adjustable nozzles, allowing the engineer to design around a single termination pressure. The test and balance contractor then has an easier time of system wide balancing to one pressure.

COIL COOLING POWER: 8 BEAM (.5 Beam Pressure, 58 F Water and 76 F Room Temperature,.5 GPM) 800 5% Water Cooling Capacity (Watts) 600 400 00 000 8000 00% Industry 05% New SEMCO IQHC New SEMCO IQHC (gpm) 600 Comparison of coil cooling power provided by the previous top performing chilled beam (benchmark) against the new IQHC beam shown at the same water flow (yellow) as an industry standard, and at the same water-side pressure loss/pump energy used (green) THE UNIVERSAL BEAM After SEMCO s first 50 U.S. chilled beam installations, it became evident that designers and contractors were disadvantaged by the chilled beam industry. At the time of order, a number of items would have to be coordinated for the beams to be fabricated for successful installation. Duct location, water location, which nozzle set, what duct size... and the list continues with the options. Then, once the beams arrive, the contractor would have to spend countless hours sorting through the beams to find the exact beam for a specified room. SEMCO has implemented the Universal Beam feature to alleviate the complications, and created a configuration solution. This streamlines and simplifies the process and reduces errors. PRIMARY AIRFLOW AT.35 OF BEAM PRESSURE FOR A 8 LONG CHILLED BEAM Slot or Nozzle Setting SEMCO IQHC ( slot settings) Competitor (4 nozzle sizes) Competitor (4 nozzle sizes) 4 NA NA 8 36 30 3 4 NA NA 4 5 NA NA 5 6 55 60 6 7 NA NA 7 86 NA NA 8 00 00 05 9 4 NA NA 0 8 NA NA 4 NA NA 56 6 50 Field Adjustable? Yes No No SIMPLE FEATURES. HUGE IMPACT. To make the design and installation as simple as possible, flexibility is a key ingredient to success. Having an easily adjustable slot means that a specific nozzle set does not have to be predetermined. The duct connection is field selectable. The water location is ideally located. These features simplify the installation, as selection of the beam now only requires knowing the beam length and type of coil. 3

LYRA Cassette Chilled Beam LYRA is the new SEMCO chilled beam cassette. It offers a very low noise level combined with high flexibility and high cooling capacity. Less than 0 db sound level for a single cassette installation Less than 5 db sound level with 3 LYRA in the same room FUNCTIONS Heating and cooling Compact chilled beam Adjustable induction Flow Pattern Control OPTIONS High airflow version Integrated Control LYRA diffuses air in 4 directions. This gives a high cooling capacity as well as a high level of comfort. Like all SEMCO active chilled beams, it provides comfort with low air velocities in the room by mixing the supply air with the ambient air. With SEMCO chilled beams system, you will also reduce your investment and operating costs. VERSIONS AVAILABLE Ceiling installation, available in x and 4 x Exposed installation, available in x and 4 x High flow version, available in x and 4 x 4

FLEXIBILITY The LYRA Cassette offers the flexibility requested in our buildings nowadays. With a smart combination of functions, LYRA can adapt itself to different layouts required during the building life time. COMFORT CONTROL FUNCTION It is an adjustable induction system which fits the performances to the needs and enables to 4 diffusion directions. 3 Symmetric or disymmetric airflow Possible to change at any time 0 EASY INSTALLATION With the fastening brackets, the installation of the cassette beam is No tools required quick, safe and easy. The system is installed in two steps. FLOW PATTERN CONTROL FUNCTION The adjustable plastic blades enable optimized air diffusion. First the rods and brackets are installed, and the beam itself is installed when the building is clean. Only one person is needed No tools required to install LYRA. Possibility to adjust the throw length according to room layout CONANDA SAFETY CONTROL FUNCTION Conanda Safety Control (CSC) maintains the Conanda effect (adhesion of the air to the ceiling) while achieving the highest possible cooling power. The position of the front panel ensures a good air diffusion whatever the airflow. ±0 +5 5

FLEXICOOL CHILLED BEAM IQSA BTU/hr The Flexicool IQSA chilled beam is an integrated system for ventilation, cooling and heating, fulfilling most needs for indoor climate. These supply air beams are designed to manage high cooling effects that, because of good mixing with room air, provide comfort and low air velocities in the occupied zone. IQSA, with a covered top side, can be used for straight and slanting duct and water connections. The beam is designed for ceiling mounting and its dimensions are suited for wide ceiling panels. The chilled beam is equipped with adjusting rails, comfort control, for the adjustment of air flow, cooling effect and flow pattern. The simple adjustment of flow pattern makes it possible to adapt to changing conditions in the room. QUICK SELECTION Cooling effect in BTU/hr including supply air 4000 IQSA-300 3000 IQSA-40 000 IQSA-80 IQSA-0 000 0 0 0 40 60 80 00 Supply air flow, cfm FUNCTIONS High Air-flow Controls Lighting Comfort control Heating PRODUCT FACTS Chilled beam IQSA for ceiling mounting Suited for standard inch ceiling module Capacity and flow directions easily adjustable Bottom plate can be pushed aside to enable adjustments of capacity as well as check-up and cleaning The diagram shows the approximate cooling effect P tot in BTU/hr with water flow q w = 0.8 GPM, temperature difference between room air and supply air t = 4 F, difference between room air and average water temperature = 4 F, pressure drop 0.5 in w.g. on the air side and maximum sound pressure level L A0 = 34 db(a). Patent pending for the sound attenuator Fastening brackets for quick and easy mounting - lift up - snap on 6

SEMCO PRODUCTS TO COMPLEMENT CHILLED BEAMS NEUTON CONTROLLED CHILLED BEAM PUMP MODULE State-of-the-art active condensation control effectively eliminates condensation Zone level water control Provides load matching with only necessary amount of cooling/ heating that the space requires Variable speed pump maximizes energy savings Allows the beam coil to be dual temperature, maximizing the amount of both cooling and heating a beam can provide TRUE 3Å WHEEL Industry s highest recovery performance (AHRI Certified) and Recovery Efficiency Ratios (RER) Contaminant carry-over to less than.045% Anti-corrosion, anti-microbial antistick face coatings standard Extruded aluminum structural hub, spokes and rim system ASCENDANT SERIES Conventional cooling and active desiccant hybrid system, optimized to deliver and control low dew point air, while minimizing regeneration energy input Can produce supply air humidity levels as low as 5 grains which can be delivered at any traditional supply air temperature High operating efficiency by utilizing conventional cooling and active desiccant dehumidification where they are most beneficial PINNACLE PRIMARY VENTILATION SYSTEM Manages 00% of a building s ventilation, humidity, and temperature, while simultaneously reducing energy loads Dual wheel dedicated outside air system designed to ventilate and deliver air direct to space Ideal primary air system utilized to decouple latent load of the building with the least amount of air Supports ductwork reduction and central plant energy reduction CHILLED BEAM WITH ACTUATED SLOTS (WEGA II, NOVA II, SILENCIA) Energy Control Motorized Energy Control FPC Control and regulation equipment Heating function: water coil or electrical coils Lighting PASSIVE CHILLED BEAM Provides convective cooling to a space without requiring air duct connection Designed for pendant or ceiling grid mount Lengths available include 4, 6, 8, 0, and feet Utilized alone, or as a supplement to active chilled beams to reduce primary air required in a high sensible load room 7

SEMCO Chilled Beams BR www.semcohvac.com WE BRING AIR TO LIFE WWW.SEMCOHVAC.COM SEMCO CHILLED BEAMS 0606 SEMCO is a global leader in air management. We specialize in the design and manufacture of a wide range of air climate and air movement solutions. Our collective experience is unrivaled. Our constant aim is to provide systems that precisely deliver the best indoor air quality and performance, as well as maximize energy efficiency. SEMCO A Fläkt Woods Company Corporate Headquarters 800 East Pointe Drive Columbia, Missouri 650 USA 573 443 48 sales.semco@flaktwoods.com To learn more about SEMCO offerings and to contact your nearest representative please visit www.semcohvac.com SEMCO embraces a policy of continuous development and improvement, the right is reserved to supply products which may differ from those illustrated and described in this publication. Certified dimensions will be supplied upon request on receipt of order. SEMCO LLC 06 All Rights Reserved. The SEMCO logo is a registered Trademark of SEMCO LLC.