Data Sheet. Abacus intruder alarm systems

Similar documents
Advantage 6 Alarm Panel

Securit 7 Alarm Panel

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation

CONTENTS. 1 INTRODUCTION 2 Planning the installation 2 Nexus 8 installation example 3

HARDWIRED CONTROL PANELS

M800, M800iD Plus, M1000 and M3000. User's Guide

PARAGON PLUS USER INSTRUCTIONS USER INSTRUCTIONS J?>5 J?>5 J?>5 J?>5 J?>5 J?>5 B??=

INSTALLATION GUIDE. For products. Gardtec 370 & 581

Contents. Glossary Introduction to the IDS Notes Understanding the Keypad Indicators Operation of the Keypad...

TS400 & TS410. Intruder Alarm Control Panels. Operating Instructions

2200 and 2200L ALARM CONTROL SYSTEMS

USER MANUAL CEF AP28 CONTROL PANEL

Security Alarm System Owner's Guide 8 sector CDS Dialler 8-24 sector Control Dialler 8-24 sector Control Securitel Version 1.0 lcopm.

Watchguard WGAP864 User Manual

IDS816 User Manual H Issued January 2009

User Guide. Contents. About this guide. i-on Style Security System

2000 SERIES DIAGNOSTIC ALARM CONTROL SYSTEM

Intruder Alarm Advice for Domestic Properties

SECURIT 700L USER MANUAL

PYRONIX LIMITED, Pyronix House, Braithwell Way, Hellaby Rotherham South Yorkshire S66 8QY England

8 plus and16 plus. User s Guide * # ent. esc GALAXY 16+ V2.XX TUE 30 JUN. IU ZST 962 Issue 2. A u B u

LS800S Intruder Alarm System. Engineering Manual

IDS800 USER MANUAL. Summary of Operation. + [ ] 2 IDS800 USER MANUAL NO K ISSUED APR 2003 VER 1.44

Master Code Arming Auto-Bypass Option - Home-Away Arming Entry Delay Off Arming

User s Information Guide R2A

A Beginners Guide to Inner Range Systems

U ser's Guide PC6010

Contents. Glossary

IDS S E C U R I T Y IDS816. User Manual MANUAL NO C ISSUED APRIL 2005 VERSION 2.00

Scantronic Leading the way in security

Elite 16D Version 16 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

Condominium Security Management System

Intruder alarm system Operating Instructions

INTRUDER ALARM GUIDE

INSTALLATION MANUAL SECURIT 802 CONTROL PANEL

Alarm Control Panel WIC-16Z4P WIC-5Z2P. User Instructions

SECURIT 700L PLUS ENGINEERING MANUAL

Version 1.03 January-2002 USER S MANUAL

Solution Ultima 862 Operators Manual ISSUE 1.10

HARDWIRED CONTROL PANELS

IDS S E C U R I T Y IDS816. User Manual MANUAL NO B ISSUED DEC 2004 VERSION 2.00

Elite 16D Version 16 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

Accenta/Optima. User Guide. UK Security Panels. Servicing Organisation (Installer) name: Telephone Number: Date of Installation: Account Number:

Master User Guide Premier Elite Series

Welcome to. Welcome to Security and Peace of Mind CASTLE CARE TECH CARE TECH CARE TECH CARE TECH

Intruder alarm system Operating Instructions

Introduction. When using an LED keypad for Abacus 6P (or some older Abacus panels) refer to the LED Operator instructions guide (Part No. Y6055).

Intruder - Fire - Water Combined Alarm

TS2500. Intruder Alarm Control Panel. SYSTEM OPEN 17:30 01 Jan ENT ESC. Setting the System. Unsetting the System RE SET

USER GUIDE HARDWIRED CONTROL PANELS

PROGRAMMING PROCEDURES (Table 3)

INSTRUCTION MANUAL PC255O

Manager Guide. Indications on the system. Using System. Indications

2-ZONE EASYFIT INTRUDER ALARM

INSTRUCTION MANUAL PC255O

IDS S E C U R I T Y IDS816. User Manual. MANUAL NO A ISSUED November 2004 VERSION 1.00

PowerWave-16. Users Operating and Programming Guide Version P/N Rev. B N.A July 2002

Racal-Guardall. Countess. User Instructions. Countess

Warning: Mains voltages are present inside control unit. No user serviceable parts inside.

PARAGON USER INSTRUCTIONS J?>5 J?>5 J?>5 J?>5 B??= CD1DEC;5I* 5-5>DBI5H9D1-1335CC9-9==5491D5?-?=9DD54 5 < * 1 < < 1 C *

POWERBRICKALARM. User Manual. For Customers PB300. Version 1.36b

CONQUEROR USER INSTRUCTIONS J?>5! J?>5 J?>5 J?>5 B??= CD1DEC;5I* 5-5>DBI5H9D1-1335CC9-9==5491D5?-?=9DD54 RINS 061 ISSUE-1

L900 series USER MANUAL

USER GUIDE WIRE-FREE HOME PROTECTION SYSTEM AG100+ CONTENTS

DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Intelligent Security & Fire Ltd

GARDTEC 580. Installation Instructions

5 Sounds and Indications

SECURIT 703 USER MANUAL

TS5160. Installation & User Guide. Compatible Equipment. CPA6 0M - Output Module Loudspeaker DC54/58 - Digital Communicators (Stand Alone Only)

THANK YOU FOR VOTING TEXECOM USER GUIDE. Security Control Panels

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE

Solution 844 Operators Manual ISSUE 1.10

Summit 3208GLD USER MANUAL. Electronics Line

TS700. Intruder Alarm Control Panel OPEN ENT 0 ESC

OPERATING GUIDE FOR YOUR RP1054D KEYPAD

THANK YOU FOR VOTING TEXECOM THANK YOU FOR VOTING TEXECOM USER GUIDE. Security Control Panels 1 INS167

Solution Ultima Series Operators Manual ISSUE 1.00

Elite 64 Version 64 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

Destiny Destiny Owners Manual

Microprocessor Intruder Alarm System User Guide

Scantronic Leading the way in security

SPECIAL CODES AUXILIARY CODES SYSTEM NOTES

SCORPION Z16040C, Z8040C and Z5120C

SPECIAL CODES AUXILIARY CODES SYSTEM NOTES

NESS 5000 SERIES DIALLER

Property of Monitronics Inc

KP600F/L LED/LCD KEYPADS. Owner's Manual. Use with AV6500 & SP850 Control panels

USER GUIDE HARDWIRED CONTROL PANELS

Gen4 Domestic Intruder Panels RELIABLE AND FLEXIBLE INTRUDER PANELS. Domestic applications

HOME SECURITY. 2 - Basic security

SECURITY SYSTEM NOTES SPECIAL CODES ENTRY / EXIT DELAY TIMES ARM / DISARM CODES ZONE DESCRIPTIONS

ALARM CONTROL PANEL AND DIALLER USER S MANUAL. Revision 4.5 A$15.00 INC GST. Ness D8 control panel User s manual

Contents. Introduction... 2 Mains Safety... 2 Good Working Practice... 2

EC-P Zone Intruder Alarm System

Power Wave LCD Keypads. Users Operating and Programming Guide Version 2.00

ALL YOU NEED TO KNOW ABOUT THE NEW STANDARDS IN ONE HANDY POCKET GUIDE. Updated for 2016 to include IA1501. Brought to you by: In association with:

Total Protection Alarm System

INSTRUCTION MANUAL FOR: WIRELESS SECURITY STARTER KIT MODEL NO: SWSKIT

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Transcription:

Data Pack Issued March 2001 232-4336 Data Sheet bacus intruder alarm systems n intruder alarm system is a secondary form of protecting a property. here is little or no point in fitting a system if you have not first considered physical protection. Locks, bolts and on some commercial properties even bars can be a very good form of protection and deterrent. lso remember that a large number of burglaries are carried out with access being gained by the front door. herefore cut down any high trees or bushes, to ensure that the vulnerable entry points cannot be worked on by the intruder without being noticed by neighbours. If the physical protection and a little pruning is carried out, then backed up with electronic protection this makes a very secure unattractive target. Before investing in a system it is very worthwhile carrying out a detailed survey of the premises. he best way to start is to draw a sketch plan of the building. hen you should be looking for vulnerable points of entry such as secluded side windows and upper level windows that are accessed by a nearby flat roof. Once the number of areas for protection have been considered, the type of detectors, warning device, and intruder alarm panel can be selected using the considerations covered in this data sheet. he bacus range of panels available from RS is designed to meet the requirements of BS4737 (Intruder alarm systems in buildings, available from HMSO or BSI) when correctly installed and programmed. larm systems explained First, some basic concepts about alarm installations in general, and how they feature in the bacus system. Operational principles You will need to divide your premises into a number of zones for alarm purposes. Each zone will be protected by an alarm detector. In certain circumstances zones may have been further divided into two alarm detector circuits (ircuit and ircuit B). Exit ime and Entry ime is the time allowed to permit the user to leave and enter the premises respectively without causing an alarm condition. One of the alarm zones must be programmed as a final exit zone. his is the last zone to be closed on exit and the first zone to be opened on entry (normally the front door). In most alarm installations one or more of the remaining alarm zones will be programmed as an Exit/Entry Route Zone. his is the area of your premises that you require to pass through after setting the alarm panel on exit or before unsetting the panel on entry (typically, the entrance hall). When a zone is programmed as an Exit/Entry Route Zone the user has free access within the zone during the Exit and Entry time without causing an alarm. Final exit and entry routes n important concept in all security alarm installations is the Final Exit and also the Entry/Exit Route. If the contact (sensors) on the final exit door is triggered when the system is set, the Detectors along the entry/exit route are programmed not to react instantaneously into an larm condition. Instead, they have a pre-set delay which gives the user time to turn off the alarm. If you deviate from the Entry/Exit Route, the alarm will Fully activate, triggering the external and internal sounders. Nite zones and day mode he alarm system is normally Set to protect the premises whilst they are unoccupied, historically this is usually at night. herefore the term Nite has been coined to describe this condition. However, zones set as Fire or Personal ttack give continuous 24 hour protection. he term Day is used to describe the condition when the panel is unset, with the 24 hours circuits in operation.

Part setting or going to bed In a domestic environment the concept of a Part-set system is very important. It is highly desirable that, during the night the unoccupied part of the house is fully protected, but free movement is allowed throughout the occupied area, for example, Upstairs. Under this Part-set condition the Staircase/Hall detector, if fitted, becomes the Final Exit Detector on your route downstairs. It is therefore programmed to delay the alarm by the Exit/Entry time allowing you to go downstairs and turn off the alarm. Bells, strobes Whatever the alarm condition, it is communicated to the immediate neighbourhood through the local audible Bell, this could also be a siren or visual Strobe (flashing light). he primary purpose of the external bell and strobe light is to attract attention in the event of an intruder entering or attempting to enter a protected zone while set. he bell/strobe unit is normally mounted at a high level outside the premises at a point which is easily heard and seen by passers by. he external bell/strobe housing will, in effect, act as a deterrent to burglary, since a potential intruder can see immediately that an intruder alarm system is fitted. Since the bell/strobe housing is normally located at the front of a premises (in order to attract attention), evidence of an alarm system may not be visible from the back of the premises. For this reason, it is normal practice to fit one or more Dummy bell housings around the premises. In certain circumstances, several Dummy bell housings can be effective (particularly on large premises). Noise batement legislation determines that an alarm bell shall not ring continuously for more than 20 minutes (maximum). For this reason, all intruder alarm bells are programmed to switch off after a preset period (up to 20 minutes). he strobe light will however, continue to operate until the alarm system is reset by you, the occupier. Zones and sensors Buildings are divided into Zones which are monitored or guarded by Sensors, also known as detectors or PIRs. hese are connected to the ontrol Panel (bacus) by wired ircuits. he bacus system allows for varying amounts of zones, see chart below. (ll bacus panels are supplied with a minimum of six zones.) Maximum Maximum number of number of RS Model zones detection points stock no. bacus 6 and 6R 6 12 627-920 bacus 8P 8 16 740-477 System components It is important that you are familiar with the various components that go to make up an alarm system, together with their function and the reason for the location selected for each component. bacus control panel he basic bacus system comprises a control panel complete with at least one keypad (on board or remote). he control panel monitors the status of the detectors and tamper loop 24 hours a day. Dependent on the mode of operation (i.e. alarm set, chime mode, entry/exit, etc.) it will produce an output condition (i.e., sounder/strobe operating, panel and keypad chime, etc.) either locally at the panel or keypad, or remotely at the sounder unit. o enable the user to operate the alarm system at convenient locations throughout the premises, up to six additional remote keypads can be fitted to the system, in addition to the main control panel. he alarm system responds to simple commands which are entered through the numeric keys on the control box or, if fitted, small unobtrusive keypads. he remote keypad allows the user to perform all user functions, as if at the main control panel. he responding messages are displayed on a 2 character (LED) screen or a 32 character (2 line) screen (LD). hese messages are highly informative and personalised, and this makes the system intelligent and user-friendly. he remote keypads have a Help Button feature, comprising two separate push buttons. When pressed simultaneously will perform a pre-selected function. he remote keypad Help buttons can be programmed by the installation engineer as Fire, Medical, Panic alarms or Set, Part Set or select the chime function. Detectors wide range of detectors is available to detect the presence of an intruder in your premises or attempting to gain unauthorised access. he type of detectors selected will depend on the type of premises, the level of protection required, the general environment surrounding the property. For normal domestic and commercial environments, these types of detector are in common use. 1. Door contacts set of magnetic contacts (switches) installed on a protected door (or a window) which will signal to the bacus alarm panel if the door is opened, (RS stock nos. 335-536, 333-192, 337-396, 333-158). 2. Vibration detector small security device fitted to a protected door, window or wall to signal to the bacus alarm panel if a large amount of vibration is detected, such as an intruder forcing a hole through a door, (RS stock no. 740-483). 3. Movement detectors For example, passive infra red or PIR. security device normally fitted at head height within a room or corridor to detect the presence of an intruder within the area covered by the detector, (RS stock no. 303-4999). 4. Panic buttons Push button devices strategically situated throughout the premises and connected to the bacus panel which signal a Duress alarm when pressed. he panic buttons are always armed and will therefore operate regardless of whether the panel is set or unset. Pressing a panic button will create a full alarm condition (External and Internal sounders). Once pressed the panic buttons normally require resetting by a special key, provided with the unit, (RS stock no. 156-6668). 2

5. Pressure pad switches hese are usually mounted underneath carpet to detect the presence of a person walking across. he most typical position is mounted under stair carpets, (RS stock nos. 317-140 and 821-942). 6. Passive Infra Red Detectors hese products detect movement in a specified zone. For further information see the PIR detectors data sheet. System layout he system layout shown below is a guide to typical positions of the system components. his will obviously vary depending on the premises and level of protection to be afforded. However the general rules given cover all installation layouts. 3

General rules 1. Final exit doors should have magnetic contact switches fitted to ensure that the premises cannot be vacated with the doors left open and also to protect against forced entry. Figure 1 Ground floor view Zone 2 Field of view Zone 3 Zone 1 final P exit Lounge Entry/ Exit route Hall Garage lternative panel position Zone 3B Dining Room Kitchen Zone 4 Zone 5 S Key: Door contacts PIR S Vibration detector P Personal attack switch Panel Note: Zone 6 may be a PIR on the first floor landing. 2. PIR detectors are best fitted where an intruder has to pass through an area to gain access (i.e. halls and landings) or to protect specific valuable items (i.e. lounge). are should be taken in siting to avoid direct sunlight, strong lighting and heat sources (hence the vibration detectors in the kitchen) as these may cause nuisance tripping. hey are best sited so the intruder cuts across the field of view, (Figure 1) (some products are specifically designed for long corridors in this instance this rule 3. does not apply), hence a corner position is usually adopted. 3. PIR, vibration detectors, etc. all have complex electronics. hese are best given their own zone as in the event of a fault occurring isolating the fault will be quicker and nuisance tripping quickly eliminated. Magnetic door contacts tend to be very reliable if installed well within their magnetic actuation limit. Hence these can be put in series together on a loop if appropriate. hey are also easier to test if faulty. 4. Wiring is best concealed where possible to prevent damage and tampering. ry to avoid running alongside mains cables as interference may occur. 5. he sounder/strobe unit should be fitted well above head height to avoid tampering. he wiring should pass directly through the wall behind the bell to make it inaccessible. 6. he control panel requires a 23ac power source. n unswitched fused spur preferably direct from the consumer unit on its own fuse wired in accordance with the current IEE regulations should be provided. Using the above general rules you should plan your installation on your sketched drawing considering the panel siting, how the cable runs can be minimised, where different types of detector will be fitted and which zone they will be on. When you have finalised your plan you can begin installation. However lets consider types of wiring first so you may select the correct cable for the installation. 4

Wiring Figure 4 3 (5) wire connection General he conventional wiring from an alarm panel consists of the detector circuit, the tamper circuit, and where the detector requires it, a 12Vdc supply, (Figure 2). Figure 2 amper circuit, B and = Detectors 12Vdc Supply to detectors{ D Systems supply amper larm 3k9 + N/ N/ N/ N/ N/ N/ B Detector circuit amper circuit + Figure 5 2 (4) wire connection Hence for a magnetic door switch 4 core cable would be required and for a PIR, 6 core cable. he detector usually has 2 sets of integral contacts both normally closed (N/) as illustrated in Figure 2 by, B and. he tamper contacts are usually activated by removal of the cover of the detector. he alarm system will give an alarm irrespective of the system setting when a tamper contact is opened. he detector contacts open when an intruder is detected. full alarm condition will only be given if the alarm is set. Note: himes may be given if the panel is programmed to do so if the alarm is not set. bacus wiring Detectors he bacus range of panels is compatible with conventional 4 and 6 wire devices, (Figure 3). However, to reduce cabling, the bacus range of panels can be wired in 3 or even 2 wire protocol (Figure 4 and Figure 5) with the simple addition of some resistors on the detectors. Figure 3 onventional 4 and 6 wire devices D Systems Supply Zone splitters s it is good practice to install one detector per zone you can soon find that you have exhausted the zones available. In order to overcome this without the need for a more expensive panel the bacus zones can be divided into and B (e.g. zone 1 and 1B etc.). his can be achieved with a Zone splitter: (RS stock no. 627-958) he zone splitter enables connection of conventional detectors as illustrated in Figure 6 using 3 wire connection to the splitter. Figure 6 Zone splitter amper 3k9 larm Zone splitter II 8k9 + B LOOP LOOP MP PIR No connection required supply amper larm + + 2 Zone ommon tamper Zone 1 Zone 1 B + Magnetic Switches 5

larm programming he bacus range of panels can easily be programmed with entry/exit routes, part setting, chime zones, fire zones, etc. Each panel is supplied with a comprehensive instruction leaflet detailing how to achieve this. s long as you have planned your layout and work carefully you will have no problem in being successful. ssociated security products It is recommended that the RS alarm control panel is used in conjunction with the products specifically designed for security applications. his data sheet has been written assuming RS security products have been used throughout. list of suitable security products is given below. Product RS stock no. 4-core signal cable 365-571 6-core signal cable 365-587 amper proof 6 way terminal block 424-361 Flexible jumper loop 424-377 Pressure pad switch (small) 317-140 Pressure pad switch (large) 317-156 Flush mounting reed proximity switch 333-158 Flush mounting reed proximity switch 337-396 Surface mounting reed proximity switch 333-192 Surface mounting reed proximity switch 335-536 Roller shutter reed proximity switch 625-671 Personal attack switch 299-4676 Zone splitter 627-958 Vibration detector 740-483 12V 3.0h lead acid battery 591-938 LD keypad 627-936 RS omponents shall not be liable for any liability or loss of any nature (howsoever caused and whether or not due to RS omponents negligence) which may result from the use of any information provided in RS technical literature. RS omponents, PO Box 99, orby, Northants, NN17 9RS elephone: 01536 201234 n Electrocomponents ompany RS omponents 1998