New Wide Wired Remote Controller

Similar documents
New Wide Wired Remote Controller

SIMPLE WIRED REMOTE CONTROLLER

Weekly Wired Remote Controller

Weekly Wired Remote Controller

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

USER S MANUAL. Wired Remote Controller MWR-WS00. System Air Conditioner ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH EΛΛHNIKA RUSSIAN

OPERATING MANUAL. AIR CONDITIONER Duct Type. Indoor Unit ARTG36LH ARTG45LH ARTG54LH ARTG60LH PART NO KEEP THIS MANUAL FOR FUTURE REFERENCE

Air Conditioner. User manual. Wired remote controller MWR-WE11N

MA Remote Controller PAR-31MAA

Wired Remote Control MWR-WE10. Air Conditioner. user manual. imagine the possibilities. Thank you for purchasing this Samsung product.

CITY MULTI Control System and Mitsubishi Air Conditioners Wireless Remote Controller PAR-SL100A-E

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36

OWNER S MANUAL. R 410A Ductless Split System Air Conditioner and Heat Pump

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

AIR CONDITIONER OWNER S MANUAL ENGLISH FRANÇAIS ESPAÑOL

OPERATING MANUAL UTY-RNNYM P/N English

OPERATING MANUAL AIR CONDITIONER DUCT TYPE. ART Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N

CONTENTS SAFETY PRECAUTIONS. En-1 DANGER! CAUTION!

Indoor Unit (2 Series)

HEAT & COOL MODEL (REVERSE CYCLE)

OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump

AIR CONDITIONER INSTALLATION MANUAL

Indoor Unit (2 Series)

Air conditioner. User manual. Wireless Remote Control AR-EC03E/EH03E/EC03M/EH03M. English 1

Wired Controller XK60

Air Conditioner. installation manual. imagine the possibilities. Wired Remote Control MWR-WE10. Thank you for purchasing this Samsung product.

KSACN0101AAA Wired Remote Controller (with Timer Function) For Ductless Systems. Owner's Manual

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

R410A. AIR CONDITIONER DUCT TYPE / ART Series OPERATING MANUAL. REFRIGERANT This Air Conditioner contains and operates with refrigerant R410A.

C&H NORDIC Commercial 4 SERVICE MANUAL

INSTALLATION MANUAL RHF025EE Series RHF035EE Series RHF050EE Series RHF080EE Series RHF100EE Series

AIR CONDITIONER OPERATING MANUAL. Duct type. Indoor Unit ARTG45LDTA ARTG54LDTA ARTG60LDTA KEEP THIS MANUAL FOR FUTURE REFERENCE. PART No.

OWNER S MANUAL VMH 09/12/18/24

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

OWNER S MANUAL. High-Wall Fan Coil Unit CONTENTS

Owner's Manual TABLE OF CONTENTS

40KMC KMQ

WARNING VL-220CZGV-E. 1. Safety Precautions LOSSNAY HEAT RECOVERY VENTILATOR (RESIDENTIAL USE) Contents. Eng-1. English

LG Concealed Duct Air Conditioner OWNER'S MANUAL

WIRED REMOTE CONTROLLER

Installation and Owner s Manual

Portable Air Conditioner 6,000 BTU 8,000 BTU 10,000 BTU

SU MO TU WE TH FR SA AM PM

Utopian Split A/C. Thank you for purchasing this quality Split A/C system!

Compact Cassette Type

Buttons on remote controller

CASSETTE TYPE. AUT Series FUJITSU GENERAL LIMITED AIR CONDITIONER OPERATING MANUAL P/N KEEP THIS MANUAL FOR FUTURE REFERENCE AM PM

Variable Refrigerant Flow (VRF) System Simple Touch Remote Control SAFETY WARNING

SERVICE MANUAL UNI SPLIT SERIES. ASC-xxBI, ASD-xxBI, ASF-xxBI, ASGE-xxBI, ASGE-xxBI-3

USER S MANUAL AQV09V A Series AQV12V A Series AQV18V A Series AQV24V A Series

MS7 Single Zone Mini Split System Air Conditioners and Heat Pumps

5) Do not start or stop the unit by inserting or pulling out the power plug.

GMSG OWNER S MANUAL SPLIT-SYSTEM ROOM AIR CONDITIONER CONTENTS

42XQ 42XQA. 42XQ : Cooling only direct expansion Fan Coil Unit (Wireless Control) 42XQA : Cooling only direct expansion Fan Coil Unit (Wired Control)

AIR CONDITIONER OWNER S MANUAL ENGLISH FRANÇAIS ESPAÑOL

EMERSON BLUE Wireless Comfor t Inter face 1F98EZ-1621 HOMEOWNER USER GUIDE

Inverter Split-type Room Air Conditioner

13500 BTU RV Air Conditioner Installation and Operating Instructions

Programmable Thermostat

INSTALLATION MANUAL AIR CONDITIONER

VENSTAR T1075 FAN COIL THERMOSTAT 7 DAY PROGRAMMABLE 2 OR 4 PIPE SYSTEMS OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

OPERATING INSTRUCTIONS

VMI-1102-A SERVICE MANUAL AIRCONDITIONER DC INVERTER MULTI TYPE MSV1I-09HRDN1-M TAS-09MVHN TAS-12MVHN INDOOR VERTU DC INVERTER MULTI SERIES

Model No.: PS08-01 PS10-01 Ref: KY80 KY100

Installation Instructions

Operating Instructions High-spec Wired Remote Controller

OWNER S MANUAL Venstar Inc. 08/07

User s Manual

VIGÖR HRV PLUS AND VIGÖR ERV

PORTABLE AIR-CONDITIONER MODEL: EPAC-A4010D(WH) Owner s Manual Please read this manual carefully before operating your set.

HEAT COOL. Meets Commercial California Title 24

Fujitsu OPERATING MANUAL Air Conditioner DUCT TYPE

Owner's Manual TABLE OF CONTENTS

DEHUMIDIFIER OWNER S MANUAL. Read this manual carefully before operating the appliance and retain it for future reference.

Operating Functions Temperature Parameters

12,000 BTU Portable Air Conditioner PE3-12R-03. Model No. PE3-12R Soleus Air International

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

Portable Air Conditioner

HEAT RECOVERY VENTILATORS MODELS HRV 90H-V ECM, 90H-V

USER MANUAL. Portable Air Conditioner and Heater With Heat Pump Technology PAC18. Please read this manual carefully prior to operating the product.

Installation and Owner s Manual

Portable Air Conditioner with Heat Pump Technology PH4-10R-01, PH4-12R-01, & PH4-14R-01 Operating Instructions


SAT-3 Room Temperature Controller

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

Ducted air conditioner Operating Manual

AIR CONDITIONER. Please read this owner, s manual carefully before using the air conditioner, and keep this manual for the future reference.

Operation Manual - PC-ARF - P IMPORTANT:

LG Room Air Conditioner

HEAT CONTROLLER, INC.

Evolution Control. Zone Control Homeowner s Guide

Set & $ave. Model Programmable Thermostat. installation and operation manual

TDU Series LCD Thermostat For EFCB and EVCB Controllers. Models. Features. Functions. Onboard Sensors. Model # Temp RH CO2 Color.

CR13000-PAC OWNER S MANUAL. Portable Air Conditioner. PORTABLE AIR CONDITIONER with HEAT PUMP. Operating and Servicing Instructions

Welcome. Important Safeguards. Please read the Manual carefully before operating the machine ELECTRICAL CONNECTIONS:

USER S MANUAL AQV09J Series AQV12J Series AQV18J Series AQV24J Series

14,000 BTU Portable Air Conditioner 14,200 BTU Heat Pump Model Number: LX-140 Operating Instructions. Model No. LX Soleus Air International

PORTABLE AIR CONDITIONER

Transcription:

LG LG New Wide Wired Remote Controller Owner's & Installation Manual Models: PQRCVSL0 PQRCVSL0QW IMPORTANT Please read this owner's & installation manual completely before installing the product. Installation work must be performed in accordance with the national wiring standards by authorized personnel only. Please retain this owner's & installation manual for future reference after reading it thoroughly. P/No.: MFL690 ITALIANO ESPAÑOL FRANÇAIS DEUTSCH êìëëäàâ PORTUGUÊS

New Wide Wired Remote Controller Owner s & Installation Manual TABLE OF CONTENTS Safety Precaution... Part Description... Installation instruction... Group control...7 Installer Setting - How to enter installer setting mode...8 Installer Setting - Test Run Mode... Installer Setting - Setting Address of Central Control... Installer Setting - E.S.P.... Installer Setting - Thermistor... Installer Setting - Ceiling Height Selection...6 Installer Setting - Static ure Setting...7 Installer Setting - Remote Controller Master/Slave Setup...8 Installer Setting - Override Master/Slave Setting...9 Installer Setting - Dry Contact Mode Setting...0 Installer Setting - Zone State... Installer Setting - Celsius / Fahrenheit Switching... Installer Setting - Zone Type Setting... Installer Setting - Zone Number Setting... Installer Setting - Emergency Heater Setting... Installer Setting - Option Function Setting...7...8 Standard Operation - Standard Cooling...8 Standard Operation - Power Cooling...9 Standard Operation - Heating Mode...9 Standard Operation - Dehumidification Mode...0 Standard Operation - Fan Mode...0 Standard Operation - Auto Operation Mode... Standard Operation - Temperature Setting/Room Temperature Check... Standard Operation - Airflow Setting... Sub function - Direct Wind / Indirect Wind... Sub function - Plasma Purification...6 Sub function - Humidifier...7 Sub function - Electric Heater...8 Sub function - Energy-Saving Cooling Operation...9 Sub function - Robot Cleaning Manual Setup...0 Function setting - Child Lock... Function setting - Robot Cleaning Automatic Setup... Function setting - Filter Sign Clear... Function setting - Elevation Grill... Function setting - Vane Angle Control... Function Setting - Change Temp...6 Function setting - Zone Control...7 Function setting - Changing Current Time...8 Function setting - Auto Cleaning...0 Programming - Simple Reservation... Programming - Sleep Reservation... Programming - ON Reservation... Programming - OFF Reservation... Programming - Weekly Reservation...7 Programming - Holiday Reservation...9 Ventilation Product User Manual - Interlinked Air conditioner and Ventilation...60 Ventilation Product User Manual - Interlinked operation with general ventilation...6 Manual Conversion - ing Ventilation button in ventilation mode will manually convert...6 Ventilation Product User Manual - Interlinked Operation with Direct Expansion Ventilation...6 Ventilation Product User Manual - Single Operation with Direct Expansion Ventilation...6 Ventilation Product Additional Operations - Fast / Power Saving...6 Ventilation Product Function Settings...66 Ventilation Product Reservations Settings...67 Ventilation Product Installer Setting Functions - Entering Method...68 Different mode drive...69 Checkups before reporting breakdown...70 New Wide Wired Remote Controller Safety Precaution Installation Be sure to request to the service center or installation specialty store when installing products. It will cause fire or electric shock or explosion or injury. Do not place flammable stuffs close to the product. It will cause fire. Request to the service center or installation specialty store when reinstalling the installed product. It will cause fire or electric shock or explosion or injury. Do not allow water to run into the product. It will cause electric shock or breakdown. Safety Precaution The installation requires expert skills, and it should be installed by the service center or other shops specialized in the installation and recognized by our company. For all the problems arising after installation by someone who has no relevant qualifications, our company will not provide free service. The following safety cautions are provided to prevent unexpected dangers or losses. WARNING : If the user does not follow the mandatory items, it may result in serious injury or death. CAUTION : If the user does not follow the mandatory items, it may cause personal injury or property damage. : Warning and Caution are to call the user s attention to the possible danger. Read and follow them carefully in order to prevent a safety accident. : Warning and Caution are indicated in this guide and the product itself to help protect the users from danger. In-use Request to the service center or installation specialty store when the product becomes wet. It will cause fire or electric shock. In-use Do not clean using the powerful detergent like solvent but use soft cloths. It will cause fire or product deformation. WARNING Do not disassemble, fix, and modify products randomly. It will cause fire or electric shock. Do not give the shock to the product. It will cause breakdown when giving the shock to the product. Do not give the shock using sharp and pointed objects. It will cause breakdown by damaging parts. CAUTION Do not press the screen using powerful pressure or select two buttons. It will cause product breakdown or malfunction. Do not touch or pull the lead wire with wet hands. It will cause product breakdown or electric shock. Owner s & Installation Manual

Part Description Part Description Name and Function of Remote Controller 0 9 8 7 Please attach the inform label inside of the door. Please choose proper language depend on your country. 6 OPERATION INDICATION SCREEN SET TEMPERATURE BUTTON FAN SPEED BUTTON ON/OFF BUTTON OPRATION MODE SELECTION BUTTON 6 WIRELESS REMOTE CONTROLLER RECEIVER Some products don't receive the wireless signals. 7 AIR FLOW BUTTON 8 SUBFUNCTION BUTTON 9 FUNCTION SETTING BUTTON 0 VENTILATION BUTTON RESERVATION UP,DOWN,LEFT,RIGHT BUTTON To check the indoor temperature, press button. ROOM TEMPERATURE BUTTON SETTING/CANCEL BUTTON EXIT BUTTON Some functions may not be operated and displayed depending on the product type. Accessory Installation instruction Installation instruction. Please fix tightly using provided screw after placing remote controller setup board on the place where you like to setup. - Please set it up not to bend because poor setup could take place if setup board bends. Please set up remote controller board fit to the reclamation box if there is a reclamation box. - Install the product so as not to make a gap with the wall side and to prevent shaking after the installation.. Can set up Wired remote controller cable into three directions. - Setup direction: the surface of wall reclamation, upper, right - If setting up remote controller cable into upper and right side, please set up after removing remote controller cable guide groove. Remove guide groove with long nose. Reclamation to the surface of the wall Upper part guide groove Right part guide groove Connection Cable (EA, 0m) Screw ( EA) Owner's / Installation manual Inform label (8EA-8Languages) <Wire guide grooves> New Wide Wired Remote Controller Owner s & Installation Manual

Installation instruction. Please fix remote controller upper part into the setup board attached to the surface of the wall, as the picture below, and then, connect with setup board by pressing lower part. - Please connect not to make a gap at the remote controller and setup board s upper and lower, right and left part. - Before assembly with the installation board, arrange the Cable not to interfere with circuit parts. Installation instruction When separating remote controller from setup board, as the picture below, after inserting into the lower separating hole using screw driver and then, spinning clockwise, remote controller is separated. - There are two separating holes. Please individually separate one at a time. - Please be careful not to damage the inside components when separating. <Connecting order> Wall Side <Separating order> Wall Side Wall Side Wall Side Group control. When installing more than units of air conditioner to one wired remote controller, please connect as the right figure. If it is not event communication indoor unit, set the unit as slave. Check for event communication through the product manual. GND Signal wire V GND Signal wire When controlling multiple indoor units with event communication function with one remote controller, you must change the master/slave setting from the indoor unit. - Indoor units, the master/slave configuration of the product after completion of indoor unit power OFF and then ON the power after minutes elapsed sign up. - For ceiling type cassette and duct product group, change the switch setting of the indoor PCB. ON ON. Please connect indoor unit and remote controller using connection cable. V Signal GND Red Yellow Black 6 New Wide Wired Remote Controller Please check if connector is normally connected. Connecting cable Indoor Unit side CAUTION Installation work must be performed in accordance with the national wiring standards by authorized personnel only. Installations must comply with the applicable local/national or international standards. Apply totally enclosed noncombustible conduit (metal raceway) in case of local electric & building code require plenum cable usage.. Please use extension cable if the distance between wired remote controller and indoor unit is more than 0m. CAUTION When installing the wired remote controller, do not bury it in the wall. (It can cause damage in the temperature sensor.) Do not install the cable to be 0m or above. (It can cause communication error.) When installing the extension cable, check the connecting direction of the connector of the remote controller side and the product side for correct installation. If you install the extension cable in the opposite direction, the connector will not be connected. Specification of extension cable: 7 007 # core shield or above. 6 7 8 6 7 8 # switch OFF: Master # switch ON: Slave (Factory default setting) - For wall-mount type and stand type product, change the master/slave setting with the wireless remote controller. (Refer to wireless remote controller manual for detail) When installing remote controllers to one indoor unit with event communication function, set the master/slave of the remote controller. (Refer to remote controller master/slave selection) When controlling the group, some functions excluding basic operation setting, fan level Min/Mid/Max, remote controller lock setting and time setting may be limited.. When installing more than wired remote controllers to one air conditioner, please connect as the right picture. When installing more than units of wired remote controller to one air conditioner, set one wired remote controller as master and the others all as slaves, as shown in the right picture. You cannot control the group as shown in the right for some products. Refer to the product manual for more detail. GND Signal wire V B Y R MASTER B Y R SLAVE <When simultaneously connecting sets of wired remote controller> When controlling in groups, set the master/slaver of the remote controller. Refer to Installer setting section on how to set master/slave for more detail. GND Signal wire V Owner s & Installation Manual 7

Installation instruction Installer Setting -How to enter installer setting mode CAUTION Installer setting mode is to set the detail function of the remote controller. If the installer setting mode is not set correctly, it can cause problems to the product, user injury or property damage. This must be set by an certificated installer, and any installation or change that is carried out by a non-certificated person should be responsible for the results. In this case, free service cannot be provided. If pressing button long for seconds, it enters into remote controller setter setup mode. - If pressing once shortly, it enters into user setup mode. Please press more than seconds for sure. When you enter the setting mode initially, Function code is displayed on the bottom of the LCD screen. Function Code Some categories of the menu may not be displayed according to the function of the product, or the menu name may be different. Value <Installer Setting Code Table> ) General air-conditioner product Installation instruction No. Function Code Value Test Run 0 0:Set Address Setting 0 00~FF : Address <ESP Step> <ESP Value> <Example> 0:VeryLow 0 ~ 0:Low E.S.P. Value 0 0:Med 0:High Function Code ESP step ESP value 0:Very High 0:Remo Thermistor Ceiling Height 0 0 0:Indoor 0:TH 0:Low 0:Med 0:High 6 Static ure 06 0:Very High 0:V-H 0:F-H 0:V-L 0:F-L 7 Master Setting 07 00:Slave If only Plus series models 00 : Group setting 0:Master 0 : Single setting 8 Override Setting 08 00:Slave 0:Master 9 Dry Contact 09 00:Auto-Off 0:Auto-On 0 Release Min. Delay 0 0:Set Zone State 0:Variable 0:Fixed Celsius 00:Celsius Fahrenheit Switching 0:Fahrenheit (Optimized only for U.S.A) 00:Zone Controller Zone Type 0:Damper Controller Zone Number 0~0(Zone number) Select mode Setup Low Ambient Heating Operation Setup FAN Speed 00 : not use 0 : not use 0 : fan off Emergency Heater 8 0 : use : use compressor off(0 /-8 )/on( /- ) : fan on Setting : use compressor off( /- )/on(0 /- ) : use compressor off(0 /- )/on( /-9 ) 6 Plasma 0 7 Electric heater 8 Humidifier 9 Elevation Grill 0 Ventilation Kit Auxiliary Heater 00: Not Installed 0: Installed Some contents may not be displayed depending on the product function 8 New Wide Wired Remote Controller Owner s & Installation Manual 9

Installation instruction ) General Ventilation product No. Function Code Value Test Run 0 0 : Test Run Setup Address Setting 0 00~FF : Address of Central Control SA(Supply Air) ESP 0 <ESP level> <ESP value> <Example> 0 : Low 0~ EA(Exhaust Air) ESP 0 0 : High 0 : Super High ESP step Function Code Product Direction 0 0 : Normal 0 : Opposite 6 Quick Refresh Priority 06 0 : Supply Air First 0 : Exhaust Air First 7 Master Setting 07 00 : Slave 0 : Master 8 Override Setting 08 00 : Slave 0 : Master 9 Dry Contact 09 00 : Auto-Off 0 : Auto-On 0 Release Of Minute Delay 0 0 : Set Zone State 0 : Variable 0 : Fixed Humidification for Singular 00 : Not in Use Ventilation 0 : Use Humidification for Heat Mode 00 : Automatic Ventilation 0 : Manual Some contents may not be displayed depending on the product function ESP value Installer Setting -Test Run Mode After installing the product, you must run a Test Run mode. For details related to this operation, refer to the product manual. Function Code Set button to start. Installation instruction If pressing button long for seconds, it enters into remote controller setter setup mode. - If pressing once shortly, it enters into user setup mode. Please press more than seconds for sure. - Please cancel the right and left of wind direction for RAC product. Setup figure '0' blinks at the lower part of indication window. During the test run, pressing the below button will exit the test run. - Select operation, temperature up/down, wind flow control, wind direction, start/stop button. 0 New Wide Wired Remote Controller Owner s & Installation Manual

Installation instruction Installer Setting - Setting Address of Central Control It's the function to use for connecting central control. Please refer to central controller manual for the details If pressing button long for seconds, it enters into remote controller setter setup mode. - If pressing once shortly, it enters into user setup mode. Please press more than seconds for sure. If entering into address setup mode by using button, it indicates as picture below. Set Group No. by pressing button.(0~f) Move to Indoor No. setting option by pressing button. Indoor No. Group No Function Code Installer Setting -E.S.P. If you set ESP incorrectly, the air conditioner may malfunction. This setting must be carried out by a certificated-technician. ESP value Function code, ESP code Installation instruction This is the function that decides the strength of the wind for each wind level and because this function is to make the installation easier. If pressing button long for seconds, it enters into remote controller setter setup mode. - If pressing once shortly, it enters into user setup mode. Please press more than seconds for sure. If entering into ESP setup mode by using button, it indicates as the picture below. ESP step Function Code ESP value Select ESP fan step by pressing button. (0: very low, 0: low, 0: medium, 0: high, 0: very high) Set Indoor No. by pressing button. Move to ESP value setting by pressing button. (It is 000 when delivering from the warehouse.) 6 7 button to save. ing button will exit settings mode. After setup, it automatically gets out of setup mode if there is no button input for seconds. When exiting without pressing set button, the manipulated value is not reflected. (It is possible to setup ESP value from to, and is the smallest and is the biggest.) button to setup ESP value. When setting ESP value on the product without very weak wind or power wind function, it may not work. New Wide Wired Remote Controller Owner s & Installation Manual

Installation instruction ESP value Function code, ESP code Select ESP fan step again by using 6 button and setup ESP value, as No. and, that corresponds each wind flow 7 8 button to save. button to exit. After setup, it automatically gets out of setup mode if there is no button input for seconds. When exiting without pressing set button, the manipulated value is not reflected. Installer Setting -Thermistor This is the function to select the temperature sensor to judge the room temperature. Installation instruction If pressing button long for seconds, it enters into remote controller setter setup mode. - If pressing once shortly, it enters into user setup mode. Please press more than seconds for sure. If moving to room temperature perception sensor selection menu by pressing button, it indicates as picture below. Please be careful not to change the ESP value for each fan step. It does not work to setup ESP value for very low/power step for some products. ESP value is available for specific range belongs to the product. Set Thermistor value by pressing button. (0: Remote Controller, 0: Indoor, 0: TH) Function Code Thermistor setting button to save. ing button will exit settings mode. After setup, it automatically gets out of setup mode if there is no button input for seconds. When exiting without pressing set button, the manipulated value is not reflected. <Thermistor Table> Temperature sensor selection Function 0 Remote controller Operation in remote controller temperature sensor 0 Indoor unit Operation in indoor unit temperature sensor 0 Cooling TH Operation of higher temperature by comparing indoor unit's and wired remote controller s temperature. (There are products that operate at a lower temperature.) Heating Operation of lower temperature by comparing indoor unit's and wired remote controller's temperature. The function of TH has different operation characteristics according to the product. New Wide Wired Remote Controller Owner s & Installation Manual

Installation instruction Installer Setting -Ceiling Height Selection This function is to adjust FAN Airflow rate according to ceiling height (For ceiling type product) If pressing button long for seconds, it enters into remote controller setter setup mode. - If pressing once shortly, it enters into user setup mode. Please press more than seconds for sure. If moving to ceiling height selection menu by pressing button, it indicates as picture below. Installer Setting -Static ure Setting button for seconds to enter the installer setting mode until timer segment displays 0:0. Installation instruction This function is applied to only duct type. Setting this in other cases will cause malfunction. If pressing button repeatedly, it moves to static pressure selection menu as picture below. Select ceiling height value by pressing button. (0:Low, 0:Medium, 0:High, 0:Very high) Select static pressure by pressing button. (0:V-H, 0:F-H, 0:V-L, 0:F-L) Function Code Thermistor setting button to save. ing button will exit settings mode. After setup, it automatically gets out of setup mode if there is no button input for seconds. When exiting without pressing set button, the manipulated value is not reflected. Function Code ure button to save. ing button will exit settings mode. After setup, it automatically gets out of setup mode if there is no button input for seconds. When exiting without pressing set button, the manipulated value is not reflected. <Ceiling Height Selection Table> Ceiling Height Level Description 0 Low Decrease the indoor airflow rate step from standard level 0 Medium Set the indoor airflow rate as standard level 0 High Increase indoor airflow rate step from standard level 0 Very high Increase indoor airflow rate steps from standard level Ceiling height setting is available only for some products. Ceiling height of Very high function may not exist depending on the indoor unit. Refer to the product manual for more details. 6 New Wide Wired Remote Controller <Static ure Setting Table> ure selection Function Zone state ESP standard value 0 V-H Variable High 0 F-H Fixed High 0 V-L Variable Low 0 F-L Fixed Low Owner s & Installation Manual 7

Installation instruction Installer Setting-Remote Controller Master/Slave Setup It is a function for settings in group control, or -remote controller control. If pressing button long for seconds, it enters into remote controller setter setup mode. - If pressing once shortly, it enters into user setup mode. Please press more than seconds for sure. If pressing button repeatedly, it moves to master/slave selection menu as picture below. Installer Setting - Override Master/Slave Setting Override master/slave selection function is, since Multi-V 7 series model, the function to prevent product's different mode operation. If it setup as the slave, It blocks to change opposite run mode to outdoor unit cycle (cooling/heating) If pressing button long for seconds, it enters into remote controller setter setup mode. - If pressing once shortly, it enters into user setup mode. Please press more than seconds for sure. Installation instruction If pressing button repeatedly, it moves to override master/slave selection menu as picture below. Select Master/ Slave by pressing button. (00: Slave, 0: Master) Select Master/ Slave by pressing button. (00: Slave, 0 : Master) 8 New Wide Wired Remote Controller Function Code Master/Slave value button to save. ing button will exit settings mode. After setup, it automatically gets out of setup mode if there is no button input for seconds. When exiting without pressing set button, the manipulated value is not reflected. Remote controller Function Master Indoor unit operates based on master remote controller at group control. (Master is set when delivering from the warehouse.) Slave Setup all remote controllers except one master remote controller to slave at group control Refer to the 'group control' part for details When controlling in groups, basic operation settings, airflow strength weak/medium/strong, lock setting of the remote controller, time settings, and other functions may be restricted. Function Code Master/Slave button to save. ing button will exit settings mode. After setup, it automatically gets out of setup mode if there is no button input for seconds. When exiting without pressing set button, the manipulated value is not reflected. Override master/slave selection function is possible to use only when it is connected to the succeeding models of Multi-V 7 series. If it is set as Override Slave, icon is displayed on LCD Display Window. (See Figure ) Figure. Owner s & Installation Manual 9

Installation instruction Installer Setting-Dry Contact Mode Setting Dry contact function is the function that is possible to use only when dry contact equipment is separately purchased/setup. If pressing button long for seconds, it enters into remote controller setter setup mode. - If pressing once shortly, it enters into user setup mode. Please press more than seconds for sure. If pressing button repeatedly, it moves to remote controller dry contact mode setup menu as picture below. Installer Setting - Zone State It is the function to setup indoor unit's wind flow to variable or fixed. - Variable : Comp ON, setup airflow. Comp OFF, weak wind - Fixed : Comp ON, setup airflow. Comp OFF, setup airflow If pressing button long for seconds, it enters into remote controller setter setup mode. - If pressing once shortly, it enters into user setup mode. Please press more than seconds for sure. Installation instruction If moving to ceiling height selection menu by pressing button, it indicates as picture below. Select Dry contact setting by pressing button. (00 : Manual, 0 : Automatic) Select Zone State rate fixing mode by pressing button. (0: Variable, 0: Fixed) Function Code Dry Contact setting value button to save. ing button will exit settings mode. After setup, it automatically gets out of setup mode if there is no button input for seconds. When exiting without pressing set button, the manipulated value is not reflected. Function Code Zone State fixing mode button to save. ing button will exit settings mode. After setup, it automatically gets out of setup mode if there is no button input for seconds. When exiting without pressing set button, the manipulated value is not reflected. What is Dry Contact? Like hotel card key and body perception sensor, it is the signal of the point of contact when using air-conditioner by interlocking. Please refer to dry contact manual for more details. 0 New Wide Wired Remote Controller Owner s & Installation Manual

Installation instruction Installer Setting-Celsius / Fahrenheit Switching This function is used for switching the display between Celsius and Fahrenheit. (Optimized only for U.S.A) If pressing button long for seconds, it enters into remote controller setter setup mode. - If pressing once shortly, it enters into user setup mode. Please press more than seconds for sure. Repeat pressing Function code. Function Code Ex) Fahrengeit Setting button to select conversion mode value Select Temperature unit mode by pressing button. (00: Celsius, 0: Fahrenheit) button to save or release. Installer Setting-Zone Type Setting Installation instruction This function is only available on some products. It is possible to setup zone new type or old one of the product which is available to install the damper controller. CAUTION If you set zone number incorrectly, the product may malfunction especially in zone control. This function must carried out by a certificated-technician. If pressing button long for seconds, it enters into remote controller setter setup mode. - If pressing once shortly, it enters into user setup mode. Please press more than seconds for sure. Repeat pressing Function code. Function Code button to select Zone type value Ex) Setting the Zone Type as "New" Select Zone Type by pressing button (00:Old, 0:New) button to save or release. New Wide Wired Remote Controller button to exit or system will automatically exit after seconds without any input. Whenever press button in Fahrenheit mode, the temperature will increase/drop degrees. button to exit or system will automatically exit after seconds without any input. Owner s & Installation Manual

Installation instruction Installer Setting-Zone Number Setting This function is only available on some products. Zone Number is to set the number of installed zones. It's possible to control only in zone new type If pressing button long for seconds, it enters into remote controller setter setup mode. - If pressing once shortly, it enters into user setup mode. Please press more than seconds for sure. Repeat pressing Function code. button to select Installer Setting- Emergency Heater Setting This function is only available on some products This function will set the Emergency Heater Setting. Emergency Heater is used to heat the space in emergency case such as heat pump error. Emergency heat is in place of and does not supplement heat pump. Emergency Heater setting Function sets following conditions: ) Emergency Heater operation while in error or outdoor unit operates cooling cycle. ) Emergency Heater operation in Low Ambient temperature ) Fan speed setting during Emergency Heater operation CAUTION This function setting must be carried out by a certified-technician. Incorrect function setting can cause fire. Installation instruction Function Code Zone Number installed Ex) Setting the Zone Number for "" Select Zone Number by pressing button (0~0 : number of zone installed) If pressing button long for seconds, it enters into remote controller setup mode. - If pressing once shortly, it enters into user setup mode. Please press more than seconds for sure. Repeat pressing Function code 8. button to select button to save or release. button to exit or system will automatically exit after seconds without any input. Setting : Low Ambient Heating Operation Setting : FAN Speed Setting during Emergency Heater Operation Setting : Heater Operation while in error or outdoor unit operates cooling cycle. Function Code Setting: Heater Operation while in error or outdoor unit operates cooling cycle. Select mode of Heater Operation while in error by pressing button 00: not use 0: use If 00 is set at this stage, setting & setting will not be available New Wide Wired Remote Controller Owner s & Installation Manual

Installation instruction Move to Low Ambient Heating Operation setting by pressing button. Installer Setting - Option Function Setting Installation instruction Setting feature for indoor unit when air cleaning / heater / humidifier / Up/down grill / Ventilation KIT /Auxiliary Heater is newly installed, or installed unit is removed. button to setup Low Ambient Heating Operation. 0 : not use : use - compressor off(0 / -8 ) / compressor on( / - ) : use - compressor off( / - ) / compressor on(0 / - ) : use - compressor off(0 / - ) / compressor on( / -9 ) Emergency heater operation in Low Ambient temperature - compressor off : Emergency heater enabled - compressor on : Emergency heater disabled Move FAN Speed Setting during 6 Emergency Heater Operation by pressing button. If pressing button long for seconds, it enters into remote controller setter setup mode. - If pressing once shortly, it enters into user setup mode. Please press more than seconds for sure. If pressing button repeatedly, it moves to the selected option function code as picture below. Select existing condition of each mode by pressing button. (00: not installed, 0 : installed) Function Plasma purification Electric heater Humidifier Elevation grill Ventilation kit Auxiliary heater Code 0 7 button to setup FAN Speed during Emergency Heater Operation. Function Code Existing condition button to save. 8 9 0 : fan off : fan on button to save. button to exit or system will automatically exit after seconds without any input. ing button will exit settings mode. After setup, it automatically gets out of setup mode if there is no button input for seconds. When exiting without pressing set button, the manipulated value is not reflected. 6 New Wide Wired Remote Controller Owner s & Installation Manual 7

Standard Operation - Standard Cooling It cools the room by comfortable and clean wind. button to turn on the indoor. Standard Operation - Power Cooling It makes the room cool using pleasant and fresh air quickly button to trun on the indoor. button to select cooling operation mode. button to select Cooling operation mode. button continuously until 'Po' displayed. Adjust the desired temperature by pressing buttons. button to check the Room temperature. When setting the desired temperature higher than room temperature, only ventilation wind is blow out instead of cooling wind. Setting Temp Range : 8 C~0 C (6 F~86 F) What is Power Cooling? Desired temperature: Po (actually 8 C) It make room temperature Wind flow: power wind } drop fast by running Wind direction: fix to air-cooling position Partial product has no power air-cooling function. Standard Operation - Heating Mode It supplies warm wind to the indoor indoor. button to turn on the Heating drive only operates at the cooling and heating model. Heating doesn't operate at cooling exclusive model. button to select Heating mode. (To check the indoor temperature, press the room temperature button.) Adjust the desired temperature by pressing buttons. When setting the desired temperature lower than room temperature, there is only ventilation wind. 8 New Wide Wired Remote Controller Owner s & Installation Manual 9

Standard Operation - Dehumidification Mode It removes humidity while air-cooling weakly. button to turn on the indoor. Standard Operation - Auto Operation Mode button to turn on the indoor. button to select Dehumidification mode. The temperature setting can not be adjusted during operation this mode. the button to select airflow rate feeble weak medium strong automatic. (The initial wind powerfulness of humidity removal drive is 'weak'.) button to select Artificial intelligence Mode. You can adjust the temperature as the picture on the right for cooling and heating model. In rainy season or high humidity climate, it is possible to operate simultaneously dehumidifier and cooling mode to remove humidity effectively. The menu item of wind powerfulness might not be partially selected according to the product. Standard Operation - Fan Mode It blows the air as it is in the indoor, not the cold wind. indoor. Mode. button to turn on the button to select Fan During operating Auto Operation mode: We can use the FAN SPEED button We can change manually to other operation mode. For the case of cooling exclusive, as the picture on the right, you can adjust the temperature from hot to cold, from "-" to "" based on "00". When cold When cool When appropriate When warm When hot Every time pressing button, you can select wind flow in order of Very Low Low Medium High Very High. When running ventilation, compressor of AHU doesn't work. Ventilation drive does not release cool wind but general fan Because it releases the wind that has no temperature difference from the room, it functions to circulate the inside air. The menu item of wind powerfulness might not be partially selected according to the product. 0 New Wide Wired Remote Controller Owner s & Installation Manual

Standard Operation - Temperature Setting/Room Temperature Check Temperature Setting We can simply adjust the desired temperature. the buttons to adjust the desired temperature. : Increase Temp. per one time pressing : Decrease Temp. per one time pressing Room temp: Indicate the current room temperature. Set temp: Indicate the temperature that user want to set. Standard Operation - Airflow Setting Wind powerfulness : You can simply adjust desired wind powerfulness. Please setup desired wind powerfulness by wind powerfulness button. Every time you press wind powerfulness, you can select the wind flow in order of feeble weak weak medium medium medium strong strong power automatic. The menu item might not be partially selected according to product function. Please refer to product manual for product s detailed function. Cooling operation: - The cooling mode doesn't work if desired temperature is higher than room temperature Please lower the desired temperature. Heating operation: - The heating mode doesn't work if desired temperature is lower than room temperature Please increase the desired temperature. Room Temperature Check Whenever press button, the room temperature will be displayed within seconds. After seconds, it turns to display the desired temperature. Because of location of remote controller, the real room temperature and the this displayed value can be different Wind direction : You can simply adjust desired wind direction. Please set desired wind direction by pressing button. You can select wind direction of (comfortable wind Up/Down and Right/Left Right/Left Up/Down) by pressing button. Partial item of wind directions might not be selected according to product function. Please refer to product manual for product s detailed function. For air-cooling drive, from 8 C to 0 C, and for heating drive, from 6 C to 0 C, you can select desired temperature. C is proper for the difference between room and outside temperature. New Wide Wired Remote Controller Owner s & Installation Manual

Sub function - Direct Wind / Indirect Wind It is the function to directly or indirectly control wind direction by body perception sensor. The method to setup direct/indirect wind Please press button. The icon of direct/indirect wind blinks on the display, and then, if pressing button, direct/indirect wind icon is fixed and the function is setup. direct wind Please press button. The icon of direct/indirect wind blinks on the display, and then, if pressing button, direct/indirect wind icon is removed and the function is cancelled. The method to cancel direct/indirect wind If pressing button, it gets out of setup mode. After setup, it automatically gets out of setup mode if there is no button input for seconds. When exiting without pressing set button, the manipulated value is not reflected. indirect wind If pressing button, it gets out of setup mode. direct wind indirect wind Direct/indirect wind function is additional function and it might not be indicated or operated at the partial product. Direct/indirect wind function is possible only when product is running. New Wide Wired Remote Controller Owner s & Installation Manual

Sub function - Plasma Purification Only products with humidifying function can use this. Sub function - Humidifier Only products with humidifying function can use this. The method to setup cleaning air Repeat pressing until icon flash. button Operate or cancel Plasma Purification function by pressing button. ( icon appears/disappears on display part up to selection ) After setting, press to exit. button After setup, it automatically gets out of setup mode if there is no button input for seconds. When exiting without pressing set button, the manipulated value is not reflected. Repeatedly pressing until icon flash. button Turn on/off HUMIDIFIER by pressing button (The icon will be displayed in case of SETTING option and disappear in reverse case.) Humidification function might not be operated at the partial product. button to exit. After setup, it automatically gets out of setup mode if there is no button input for seconds. When exiting without pressing set button, the manipulated value is not reflected. Cleaning air function is additional function and it might not be indicated or operated at the partial product. Cleaning air function is possible only when product is running. If you want independent cleaning air drive, please setup cleaning air by pressing additional drive button at ventilation drive. 6 New Wide Wired Remote Controller Owner s & Installation Manual 7

Sub function - Electric Heater It is a function to strengthen the heating ability by turning on the electric heater during the heating operation. It can only be set during heating operation. Repeatedly pressing until icon flash. button Turn on/off ELECTRIC HEATER by pressing button (the icon will be displayed in case of SETTING option and disappear in reverse case.) button to exit. After setup, it automatically gets out of setup mode if there is no button input for seconds. When exiting without pressing button, the manipulated value is not reflected. Heater function is additional function and it only operates in selected models. The indoor unit product with Auxiliary Heater function set automatically displays (0) icon during the AUXILIARY HEATING OPERATION. Sub function - Energy-Saving Cooling Operation Power saving air-cooling function is the function to improve use's comfortableness and power saving capacity by adjusting desired temperature while running air-cooling Repeatedly pressing until icon flash. button Operate or cancel Energy-Saving function by pressing button. (To cancel power saving function, you move to power saving menu by pressing button, and then if pressing button, power saving icon disappears and the function is cancelled. ) button to exit. After setup, it automatically gets out of setup mode if there is no button input for seconds. When exiting without pressing set button, the manipulated value is not reflected. When using non-heat recovery out door unit, emergency heater can be turned on for simultaneous heating and cooling. Indoor unit with the emergency heater must be turned OFF for simultaneous cooling and heating Heater function is additional function and it only operates in selected models. Emergency heater can be turned on while in error code in case of emergency. Electric heater icon is displayed on LCD display window with error code when emergency heater is on while in error Exception case: Error code,,9,0 If the previous mode of the Indoor unit is COOL, DRY or FAN ONLY mode, heater must be turned on manually. Power saving function is possible to setup only when running air-cooling. Power saving function might not be operated at the partial product. 8 New Wide Wired Remote Controller Owner s & Installation Manual 9

Sub function - Robot Cleaning Manual Setup Robot cleaning function is the function for cleaner attached to the product to automatically clean the filter when using air-conditioner for the specific period of time. Repeatedly pressing until icon flash. button Function setting - Child Lock It is the function to use preventing children or others from careless using. button repeatedly until the is flashing. Turn on/off Smart Clean function by pressing button. When the cleaning is finished, the smart cleaning display disappears automatically. To cancel robot cleaning manual setup function, you move to power saving menu by pressing button, and then if pressing button, "robot cleaning" icon disappears and the function is cancelled. After setting, press button to exit. Robot cleaning manual setup function might not be operated at the partial product. When exiting without pressing set button, the manipulated value is not reflected. If moving to 'setup' icon area by using button, 'setup' icon blinks, and child lock function is setup if pressing button at that time. When cancelling lock function, if moving to 'cancel' icon by pressing button and then, pressing button, child lock function is cancelled. button to exit. After setup, it automatically gets out of setup mode if there is no button input for seconds. When exiting without pressing set button, the manipulated value is not reflected. 0 New Wide Wired Remote Controller Owner s & Installation Manual

Function setting - Robot Cleaning Automatic Setup Robot cleaning function is the function of cleaner attached to the product to automatically clean filter when using air-conditioner for the specific period of time. Set manual or automatic mode of smart cleaning. button repeatedly until the is flashing. When the flashing, press button to set/clear this function. Function setting - Filter Sign Clear This function is to clear the indicator of indoor filter cleaning. button repeatedly until the is flashing. When the is flashing, press the to clear this display Set state : Enable Auto Smart Clean function When filter is covered by dust, it will reduce cooling/heating efficiency and accumulate more electric power. Therefore. do clean the filter whenever cleaning time is expired. Clear state : Disable Auto Smart Clean function Filter cleaning indication is automatically cancelled without the separate cancellation after certain period of time. When returning to manual robot cleaning, manual function is cancelled if moving to 'manual' icon by pressing Right/Left button and then, pressing button. button to exit. After setup, it automatically gets out of setup mode if there is no button input for seconds. When exiting without pressing set button, the manipulated value is not reflected. Robot cleaning function is an additional function of the product and might not be operated at the partial product. New Wide Wired Remote Controller Owner s & Installation Manual

Function setting - Elevation Grill This function is to move the indoor filter up/down for cleaning filter. button Repeat pressing icon flash. button until Move to descent using button and press button will display descent icon and the up/down grill will descent. When up/down grill descents to the desired position, move to stop icon suing button and press button to stop up/down grill. When filter cleaning is finished, fix the filter to the up/down grill, move to ascent icon using button, and press button to ascent up/down grill. button to exit. After setup, it automatically gets out of setup mode if there is no button input for 60 seconds. When exiting without pressing set button, the manipulated value is not reflected. Elevation grill function only operates in the indoor unit with the elevation grill. Function setting - Vane Angle Control This function is to adjust angle at which airflow is blow out. Repeat pressing icon flash. button until button to select active vane : / / / / All / Standard Select Vane number using buttons. Vane number : No.,.,,, all, or standard - Selected vane is in operation. - Please verify the operating vane. - To set the angle of all the vanes, select 'all'. - To set as the factory default settings, select 'standard'. Select wind angle using button, and press button. - The boundary of wind angle settings can be changed to levels or 6 levels according to the product. - When selecting 'standard' for Vane number, the wind angle does not move. Set the wind angles for the remaining vanes as the same as above. There are products with vanes with no. and no. only according to the product types. button to exit. After setup, it automatically gets out of setup mode if there is no button input for 60 seconds. When exiting without pressing set button, the manipulated value is not reflected. button to complete and 6 active the setting process. (Airflow direction function will be released whenever setting vane angle) 7 button to exit or system will automatically release without any input after seconds. New Wide Wired Remote Controller Owner s & Installation Manual

Function Setting - Change Temp Change temperature is the function to setup air-cooling and heating drive automatically changeable according to the temperature at artificial intelligence drive mode. Repeat pressing icon flash. button until Function setting : Zone Control To turn on/off the zones by used of it Repeat pressing icon flash. button until Ex) Turn on the zone and zone. button to change. Converting temp value : ~7 button to select the zone that which one you want to turn on/off. button to complete and active the setting process. button to turn on/off zone. button to exit or system will automatically release without any input after seconds. When exiting without pressing set button, the manipulated value is not reflected. button To select other zones If you want. Then, button to turn on/off that zone as mentioned above button to exit or system will automatically release without any input after seconds. When exiting without pressing set button, the manipulated value is not reflected. 6 New Wide Wired Remote Controller Owner s & Installation Manual 7

Function setting - Changing Current Time Please press function setup button. If pressing function setup button repeatedly, it moves to time setup menu. Time setup icon is indicated at that time and date blinks at current time indication area. Ex) Changing Current Time as 'Monday / AM 0:0'. day. key to adjust the current 7 button to move to 'Minute' setting mode. (the 'Minute' segment will flash) Setting Minute value by pressing 8 button. key to move to AM/ PM setting mode (the 'AM/ PM segment will flash). 9 button to finish. Setting AM/ PM value by pressing button. button to move to 'Hour' setting mode. (the 'Hour' segment will flash) 0 In the process, press button to release and exit from setting mode. (In case of exit with incomplete information, it will return to the previous setting) When exiting without pressing set button, the manipulated value is not reflected. Setting Hour value by pressing 6 button. 8 New Wide Wired Remote Controller Owner s & Installation Manual 9

Function setting - Auto Cleaning The method to setup Automatic Drying Please press button. Move to automatic drying menu by pressing button twice. 'Automatic Drying' icon will be displayed and the current status, 'DISABLE' will blink. Programming - Simple Reservation You can set the reservation conveniently in the units of hour from hour to 7 hours. button to enter the Programming mode. (the segment flashing) Ex) Setting Simple Reservation time as ''. time. button to adjust reservation button to finish setting. If moving to ABLE icon area by using button, ABLE icon blinks, and automatic dry function is setup if pressing button at that time. button to exit. After setup, it automatically gets out of setup mode if there is no button input for seconds. When exiting without pressing set button, the manipulated value is not reflected. When returning to automatic dry no use, automatic dry function is cancelled if moving to DISABLE icon by pressing button and then, pressing button. If pressing button, it gets out of setup mode. After setup, it automatically gets out of setup mode if there is no button input for 60 seconds. When exiting without pressing set button, the manipulated value is not reflected. When simple reservation setup, product automatically runs or stops after the time that is set. Automatic dry function might not be operated at the partial product. 0 New Wide Wired Remote Controller Owner s & Installation Manual