Accessories for SMA Inverters Fan Retrofit Kit FANKIT02-10

Similar documents
Accessories for SMA Inverters Fan Retrofit Kit FANKIT02-10

Central Inverter SUNNY CENTRAL 500-US

Installing the assembly SIMATIC. Installing the assembly. Overview 1. Installing the assembly. Getting Started A5E

20 High velocity Air

Installation Manual February Opticom Infrared System. Model 575 Confirmation Light Kit

User Manual. Juice Extractor MODEL: WJE2BSLA

Owner s Manual & Safety Instructions

Owner s Manual. PIR-1 IR Learner

ELECTRIC FIREPLACE HEATER WITH SINGLE GLASS DOOR

Coffee Machine Zia series

AE R4 July 2015 Guide for the Use of R-290 Refrigerant in Copeland Refrigeration Compressors

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

IntelliDoX Operator Manual

Retrofit Instructions for Tower Dryer Moisture Sampler Blower Kit

INSTALLATION GUIDE. AXIS A1001 Network Door Controller


POWERED ANODE SYSTEM

MAN AUTO IMPORTANT INSTRUCTIONS PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING APPLIANCE

Supplement to operating and installation manual no for the VR 81 remote control unit

Appearance and sensing characteristic Specification (temperature range) Model 10 to 70 C ES1B. 2 mm 20 mm 40 mm 60 mm. 40 dia. 60 dia.

Environmental Monitoring SmartSlot Card

Operator s Manual. Model G32-S Model G32-E Disinfection Soak Stations

Introduction... 1 System Overview... 1 System Diagram... 2

expandable led Installation & Maintenance Guide Product Description Light 48 IN 21.6W 10K/460nm Expandable Light 36 IN 15W 10K/460nm Expandable

Coffee Machine Zia series

Keysight 85025/85026 Detector Exchange Program - All Serial Numbers

Installation and operating instructions. Temperature difference controller 6 inputs, 3 outputs, integrated data logger for SD card

Use this product according to this instruction manual. Please keep this instruction manual for future reference. MODELS: ST-H15-B & ST-H30

3500 Installation and Operation Instructions

Coffee Machine Siro Touch 600 series

CARE AND USE GUIDE UNDER ARMOUR HYDRATION BOTTLES

2CKA001473B System Manual Busch-Infoline. Handicapped toilet signal set 1510 UC

Owner s Manual PUH1500. Electric Umbrella Heater. Model Number: Model Number Part Number. Quality checked by: R00

IMpORTANT SAFETy INSTRUcTIONS

Digital Heat Block User Manual

Model Number Structure

Original Operation Manual Slow Juicer

CARE AND USE GUIDE VACUUM INSULATED HYDRATION BOTTLE

AM1 alarm module. RESOL AM1 alarm module * * Mounting Connection Function. Manual

APC BC300 Series 40kW 208/450/480V User Guide

Towel Warmer. Luxurious warmth for towels, robes and blankets

PM100/PM100E PLANTER MONITOR. Operator s Manual

Installation Manual. THM-0100 Setpoint Thermostat Version THM HBX Control Systems Inc.

Installation and Operation Manual

(HSTAT Series) Instruction Manual

Remote Relay Module (RRM)

1500 Watt OIL FILLER RADIATOR INSTRUCTION MANUAL. pure indoor living MODEL BOF2001-CN

Silicone Rubber Heating Tape with Adjustable Thermostat Control (HSTAT Series) Instruction Manual

Air Purifier. User s Guide. Important! Oreck Air Purifier with HEPA Filtration. Read this manual carefully, and keep for future reference.

SolarPRO CURVE HEATER OWNER S MANUAL

Operating Instructions Edition 11/2005. Process monitoring Ex-barrier for Diagnostics Unit SITRANS DA400 7MJ2010-1AA. sitrans

Operator s Manual. Model G17-EU (International) Disinfection Soak Station for Hysteroscopes, Cystoscopes and ENT scopes

MaxLite 4, 6, 8 & 9 LED Architectural & Commercial Downlights

Towel Warmer MAKE EVERYDAY A SPA DAY

Pressurized Filter Up to 1250 gallons

Embedded Linux with VAR-SOM-MX6 Course

EXPANDABLE 0.5W LED FRESHWATER LIGHT FIXTURES

Four Post Boot & Glove Dryer

Industrial Vacuums, Inc

RTO. User guide 05/

INSTRUCTIONS. OJ-DV-Relay-Module. OJ Drives A DRIVES PROGRAMME DEDICATED TO VENTILATION SOLUTIONS. Optional module for OJ-DV motor controller

Installation and Operating instructions for. C9900-U battery pack. Version: 2.0 Date:

Application Note on Reading the Vigilohm IM400 Insulation Monitoring Device Installed in Conext Core XC and XC-NA Series Inverters

150 WATT PORTABLE CLAMP LIGHT 35149

INSTALLATION INSTRUCTIONS

AUTO SPEED BLENDER INSTRUCTION MANUAL MODEL: BLCLMB1

Installation Manual NPE-180A/240A WARNING. Add-on Controller Installation Kit

B Saneo. Saneo. Saneo BS Saneo CS Saneo BW Saneo CW. C Saneo BLP Saneo CLP. Dometic Dometic. Dometic Dometic. Dometic Dometic.

For use with models: BP , BP , BP

Safety Instructions. Be sure to observe the following instructions when using the device.

Original instructions JSNY7 Magnetic switch

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

ES2-HB-N. Ordering Information. Specifications. Temperature/Humidity Sensor ES2-THB-N. Humidity Sensor

GEM-C Wireless User & Installation Manual. Revision October Apollo Solar Electric Limited. Documentation

3-way switching valve

INSTALLATION MANUAL ICE/BEVERAGE DISPENSER MODEL: ENDURO-200/250

Warranty. Thanks. Thank you for purchasing the Oliso Smart Iron, a safer, smarter way to iron.

Fig. 1 - Unit PHD4 and WPH4

Module de relais Relay Module. Manuel de l utilisateur 301RW. User Manual ERP /07

Quick-Start Operating Guide Document No Acrylic Vacuum Chambers Copyright 2010 Terra Universal Inc. All rights reserved. Revised October 2010

Active Sport Massager

BX Series. Installation, Operation, Maintenance Instructions & Spare Parts

User s Guide HHAQ-109. Portable Multi-gas Detector. Shop online at omega.com SM

Cavitator Ultrasonic Cleaners

User Manual. Wine Cellar

Scale 0: 10 k Scale 50: 10 k (see note 2)

Installation & Maintenance Guide

Iconic Series ControlLink Pushbutton 41EPBM-VW PDL356PBSS-VW. Installation Instructions REGISTERED DESIGN

Operator s Manual. The Bullet Blender 50 BB50-AU, BB50-DX. Contents. Congratulations!

SAVE THESE INSTRUCTIONS

Packaged Heat Pumps. Owner s Guide to Operating and Maintaining Your Heat Pump

2-in-1 Corded Stick Vacuum Cleaner

Installation and Operation Manual. 445 Procedures Cart. Page 3. Page 5. Page 8. Page 10. Important Information Page 2. Installation.

C L E A N I N G / M A I N T E N A N C E WA R R A N T Y I N F O R M AT I O N CLEANING/MAINTENANCE FAN STORAGE 3 YEAR LIMITED WARRANTY INSTRUCTIONS

Thanks for shopping with Improvements! Solar Pool Heater XF Item #

TECHNICAL NOTICE GH/GHO/GAE V

Installation and operation manual DPC200 - DIFFERENTIAL PRESSURE CONTROLLER. Low pressure with PI-control-mode

Wrap-Around TOTE Tank / IBC Heaters (TOTE and TOT Series)

Owner s Information Manual

READ AND FOLLOW ALL SAFETY INSTRUCTIONS

Transcription:

Accessories for SMA Inverters Fan Retrofit Kit FANKIT02-10 Installation Manual FANKIT02-IA-US_en-10 IMUS-FANK-TL21 Version 1.0 CA US

SMA America, LLC Legal Restrictions Legal Restrictions Copyright 2013 SMA America, LLC. All rights reserved. No part of this document may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, be it electronic, mechanical, photographic, magnetic or otherwise, without the prior written permission of SMA America, LLC. Neither SMA America, LLC nor SMA Solar Technology Canada Inc. makes representations, express or implied, with respect to this documentation or any of the equipment and/or software it may describe, including (with no limitation) any implied warranties of utility, merchantability, or fitness for any particular purpose. All such warranties are expressly disclaimed. Neither SMA America, LLC nor its distributors or dealers nor SMA Solar Technology Canada Inc. nor its distributors or dealers shall be liable for any indirect, incidental, or consequential damages under any circumstances. (The exclusion of implied warranties may not apply in all cases under some statutes, and thus the above exclusion may not apply.) Specifications are subject to change without notice. Every attempt has been made to make this document complete, accurate and up-to-date. Readers are cautioned, however, that SMA America, LLC and SMA Solar Technology Canada Inc. reserve the right to make changes without notice and shall not be responsible for any damages, including indirect, incidental or consequential damages, caused by reliance on the material presented, including, but not limited to, omissions, typographical errors, arithmetical errors or listing errors in the content material. All trademarks are recognized even if these are not marked separately. Missing designations do not mean that a product or brand is not a registered trademark. SMA America, LLC 3801 N. Havana Street Denver, CO 80239 U.S.A. SMA Solar Technology Canada Inc. 2425 Matheson Blvd. E 8th Floor Mississauga, ON L4W 5K5 Canada Installation Manual FANKIT02-IA-US_en-10 3

Important Safety Instructions SMA America, LLC Important Safety Instructions SAVE THESE INSTRUCTIONS This manual contains important instructions for the following products: SB 3000TLUS-22 SB 4000TLUS-22 SB 5000TLUS-22 This manual must be followed during installation and maintenance. The product is designed and tested according to international safety requirements, but as with all electrical and electronic equipment, certain precautions must be observed when installing and/or operating the product. To reduce the risk of personal injury and to ensure the safe installation and operation of the product, you must carefully read and follow all instructions, cautions and warnings in this manual. Warnings in this document A warning describes a hazard to equipment or personnel. It calls attention to a procedure or practice, which, if not correctly performed or adhered to, could result in damage to or destruction of part or all of the SMA equipment and/or other equipment connected to the SMA equipment or personal injury. Symbol Description DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury. WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury. CAUTION indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. NOTICE is used to address practices not related to personal injury. 4 FANKIT02-IA-US_en-10 Installation Manual

SMA America, LLC Important Safety Instructions Warnings on this product The following symbols are used as product markings with the following meanings. Symbol Description Warning regarding dangerous voltage The product works with high voltages. All work on the product must only be performed as described in the documentation of the product. Beware of hot surface The product can become hot during operation. Do not touch the product during operation. Electric arc hazards The product has large electrical potential differences between its conductors. Arc flashes can occur through air when high-voltage current flows. Do not work on the product during operation. Risk of Fire Improper installation of the product may cause a fire. Observe the operating instructions Read the documentation of the product before working on it. Follow all safety precautions and instructions as described in the documentation. Installation Manual FANKIT02-IA-US_en-10 5

General Warnings SMA America, LLC General Warnings General Warnings All electrical installations must be made in accordance with the local and National Electrical Code ANSI/NFPA 70 or the Canadian Electrical Code CSA C22.1. This document does not and is not intended to replace any local, state, provincial, federal or national laws, regulation or codes applicable to the installation and use of the product, including without limitation applicable electrical safety codes. All installations must conform with the laws, regulations, codes and standards applicable in the jurisdiction of installation. SMA assumes no responsibility for the compliance or noncompliance with such laws or codes in connection with the installation of the product. The product contains no user-serviceable parts. For all repair and maintenance, always return the unit to an authorized SMA Service Center. Before installing or using the product, read all of the instructions, cautions, and warnings in this manual. Before connecting the product to the electrical utility grid, contact the local utility company. This connection must be made only by qualified personnel. Wiring of the product must be made by qualified personnel only. 6 FANKIT02-IA-US_en-10 Installation Manual

SMA America, LLC Table of Contents Table of Contents 1 Information on this Document........................... 9 2 Safety............................................. 10 2.1 Intended Use........................................... 10 2.2 Skills of Qualified Persons................................. 10 2.3 Safety Precautions....................................... 11 3 Scope of Delivery.................................... 12 4 Product Description.................................. 13 5 Installation......................................... 14 5.1 Installation Area Overview................................ 14 5.2 Installing the Fan Retrofit Kit in the Inverter.................... 14 6 Disassembly........................................ 17 6.1 Disassembling the Fan Retrofit Kit........................... 17 6.2 Disposing of the Fan Retrofit Kit............................. 18 7 Technical Data...................................... 19 7.1 Fan................................................... 19 8 Contact............................................ 20 Installation Manual FANKIT02-IA-US_en-10 7

Table of Contents SMA America, LLC 8 FANKIT02-IA-US_en-10 Installation Manual

SMA America, LLC 1 Information on this Document 1 Information on this Document Validity This document is valid for the fan retrofit kit type "FANKIT02-10". Target Group This document is intended for qualified persons. Only qualified personnel with the appropriate skills are allowed to perform the tasks described in this document (see Section 2.2 "Skills of Qualified Persons", page 10). Additional Information Links to additional information can be found at www.sma-solar.com: Document title SUNNY BOY 3000TL-US SUNNY BOY 4000TL-US SUNNY BOY 5000TL-US Document type Installation manual Symbols Symbol Explanation Indicates information that is important for a specific topic or objective, but is not safety-relevant Indicates a requirement for meeting a specific goal Desired result A problem that could occur Nomenclature Complete designation PV plant SMA America Production, LLC SMA Solar Technology Canada Inc. Sunny Boy Designation in this document PV plant SMA SMA Inverter, product Installation Manual FANKIT02-IA-US_en-10 9

2 Safety SMA America, LLC 2 Safety 2.1 Intended Use The fan retrofit kit provides supplementary cooling for inverters operating at high ambient temperatures. The fan retrofit kit is authorized for use with the following inverters only: SB 3000TLUS-22 SB 4000TLUS-22 SB 5000TLUS-22 Any other uses not recommended by SMA Solar Technology AG are not permitted. For safety reasons, it is not permitted to modify the product or install components that are not explicitly recommended or distributed by SMA Solar Technology AG for this product. The enclosed documentation is an integral part of this product. Read and observe the documentation. Keep the documentation in a convenient place for future reference. The fan retrofit kit may only be used in accordance with the specifications of the attached manual. Any other use can result in personal injury or property damage. Also observe the relevant inverter manual. 2.2 Skills of Qualified Persons The tasks described in this document must be performed by qualified persons only. Qualified persons must have the following skills: Knowledge of how an inverter works and is operated Training in how to deal with the dangers and risks associated with installing and using electrical devices and plants Training in the installation and commissioning of electrical devices and plants Knowledge of all applicable standards and directives Knowledge of and adherence to this document and all safety precautions 10 FANKIT02-IA-US_en-10 Installation Manual

SMA America, LLC 2 Safety 2.3 Safety Precautions Danger to life from electric shock due to high voltages in the inverter High voltages that can cause fatal electric shocks are present in the live components of the inverter. All work on the inverter must be carried out by qualified persons only. Prior to performing any work on the inverter, disconnect the inverter on the AC and DC sides (see inverter installation manual). Always operate the inverter with the enclosure lid closed. Danger to life from electric shock due to damaged devices Operating a damaged inverter can lead to hazardous situations that result in death or serious injuries due to electric shock. Operate the inverter only if it is technically safe and in full working order. Check the inverter regularly for visible damage. Operate the inverter only if there is no visible damage. Risk of burns from hot surfaces The surface of the inverter can get very hot. Touching the surface can lead to burns. Do not touch hot surfaces. During operation, do not touch any parts other than the lower enclosure lid of the inverter. Observe the safety messages on the inverter. Electrostatic discharge can damage the inverter Touching electronic components can cause damage to or destroy the inverter through electrostatic discharge. Ground yourself before touching any components. Do not open the upper enclosure lid. Observe local regulations All electrical installations must be made in accordance with the electrical standards applicable on-site and the National Electrical Code (ANSI/NFPA 70). Installations in Canada must be carried out in accordance with the applicable Canadian standards. Installation Manual FANKIT02-IA-US_en-10 11

3 Scope of Delivery SMA America, LLC 3 Scope of Delivery Check the scope of delivery for completeness and any externally visible damage. Contact your specialty retailer if the scope of delivery is incomplete or damaged. Figure 1: Components included in the scope of delivery Item Quantity Designation A 1 Fan with fan casing, cable and cable gland B 1 Installation manual 12 FANKIT02-IA-US_en-10 Installation Manual

SMA America, LLC 4 Product Description 4 Product Description The fan retrofit kit provides supplementary cooling for inverters operating at high ambient temperatures. Figure 2: Design of the fan retrofit kit Item A B C Designation Fan with fan casing Cable gland with nut Plug Symbol on the Product Symbol Designation Explanation Beware of dangerous voltage The product operates at high voltages. All work must be carried out by qualified persons only and in accordance with this document. Installation Manual FANKIT02-IA-US_en-10 13

5 Installation SMA America, LLC 5 Installation 5.1 Installation Area Overview Figure 3: Item A B C D Installation area in the inverter with the lower enclosure lid open and the display flipped up Designation Cable route Enclosure opening for connection of the fan retrofit kit Installation location for the controller assembly Enclosure opening for fan with fan casing 5.2 Installing the Fan Retrofit Kit in the Inverter 1. Disconnect the inverter from voltage sources (see the inverter installation manual). 2. Loosen the screws of the lower enclosure lid and remove the enclosure lid. 3. Loosen the screw on the display and flip the display up until it clicks into place. 4. Remove the cover from the enclosure opening for the fan casing. 14 FANKIT02-IA-US_en-10 Installation Manual

SMA America, LLC 5 Installation 5. Insert the fan with fan casing into the enclosure opening. The arrow on the fan casing must point towards the display. 6. Hook the detents on the right-hand side of the fan casing underneath the wall of the enclosure and press the fan with fan casing into the enclosure opening. The left-hand detents snap into place. 7. Remove the filler-plugs from left-hand enclosure opening. Retaining the filler-plug Keep the filler-plug in a safe place. It may be needed again if the the fan retrofit kit is later removed from the inverter (see Section 6.1 "Disassembling the Fan Retrofit Kit", page 17). 8. Unscrew the counternut from the supplied cable gland for the fan cable. 9. Insert the fan cable through the left-hand enclosure opening from the outside into the inverter. 10. Insert the fan cable gland in the enclosure opening and fasten from the inside to the enclosure using the counternut. 11. Fasten the swivel nut hand-tight. 12. Ensure that the fan cable is securely positioned. Installation Manual FANKIT02-IA-US_en-10 15

5 Installation SMA America, LLC 13. Insert the fan plug into the fan connection of the emergency power module. 14. Flip the display down and fasten the screw hand-tight. 15. Close the inverter and recommission it (see the inverter installation manual). 16 FANKIT02-IA-US_en-10 Installation Manual

SMA America, LLC 6 Disassembly 6 Disassembly 6.1 Disassembling the Fan Retrofit Kit 1. Disconnect the inverter from any voltage sources (see the inverter installation manual). 2. Loosen the screws of the lower enclosure lid and remove the enclosure lid. 3. Wait for the fan to stop rotating. 4. Loosen the screw on the display and flip the display up until it clicks into place. 5. Release and remove the fan plug. 6. Loosen the fan cable gland. To do this, unscrew the inside counternut. 7. Remove the fan cable along with the cable gland and the nut from the inverter. Installation Manual FANKIT02-IA-US_en-10 17

6 Disassembly SMA America, LLC 8. Insert the filler-plug into the left-hand enclosure opening. 9. Flip the display down and fasten the screw hand-tight. 10. Push both detents of the fan casing towards the fan and remove the fan along with the fan casing. 11. Close the inverter (see inverter installation manual). 6.2 Disposing of the Fan Retrofit Kit Dispose of the fan retrofit kit in accordance with the applicable disposal regulations for electronic waste. 18 FANKIT02-IA-US_en-10 Installation Manual

SMA America, LLC 7 Technical Data 7 Technical Data 7.1 Fan General Data Width x height x depth 60 mm x 60 mm x 25.4 mm Noise emission (typical) 29 db(a) Maximum operating altitude 3,000 m Volumetric flow rate 40 m 3 /h Electrical Parameters Input voltage Nominal DC current 0 V to15 V 0.2 A Climatic Conditions Temperature range 40 C to +60 C Installation Manual FANKIT02-IA-US_en-10 19

8 Contact SMA America, LLC 8 Contact If you have technical problems concerning our products, contact the SMA Service Line. We need the following data in order to provide you with the necessary assistance: Device type of the fan retrofit kit Device type and serial number of the inverter Detailed description of the problem SMA Solar Technology America, LLC 6020 West Oaks Blvd, Ste 300 Rocklin, CA 95765 Tel. +1 916 625 0870 Tel. +1 877-MY SMA TECH Tel. +1 877 697 6283 (Toll free, available for USA, Canada and Puerto Rico) Fax +1 916 625 0871 Service@SMA-America.com www.sma-america.com SMA Solar Technology Canada Inc. 2425 Matheson Blvd. E, 8th Floor Mississauga, ON L4W 5K5 Canada Tel. +1 877 506 1756 (Toll free, available for Canada) Service@SMA-Canada.ca www.sma-canada.ca 20 FANKIT02-IA-US_en-10 Installation Manual

SMA Solar Technology www.sma-solar.com SMA America, LLC www.sma-america.com