Sensall Sapphire. Thermo MeasureTech ULTRASONIC POINT LEVEL SYSTEM

Similar documents
Sapphire ULTRASONIC POINT LEVEL SYSTEM

Sapphire. Ultrasonic Point Level System User Guide P/N Part of Thermo Fisher Scientific. Revision C

Ultrasonic Point Level Switches

Ultrasonic Switches. Features & Benefits

Brooks MT3600 Series Metal Tube Variable Area Flowmeters

Electronic Flow Switches

Glass Tube Variable Area Flowmeter

Installation and Operating Instructions

High Pressure Conductivity Monitor

E C H O T E L C O N T A C T U L T R A S O U N D

ECHOTEL 961/962. Ultrasonic level switches. Worldwide level and flow solutions DESCRIPTION. Loop or line powered FEATURES AGENCY APPROVALS

Metal Tube Variable Area Flowmeter with Optional Electronics based on Smart Meter Manager Technology

Brooks Models MT 3809 and 3819 Metal Tube Variable Area Flowmeters with Optional Electronics based on Smart Meter Manager TM Technology

ABB MEASUREMENT & ANALY TICS DATA SHEET. RS85 Vibrating fork level switch

Sanitary Pressure Transmitter

Enraf Servo Gauge 854 ATG

Rosemount 752 Fieldbus Remote Indicator

Enraf Servo Gauge 854 XTG

VIBRATION TRANSMITTER MODEL 140T INSTALLATION The mounting orientation can be in any position. This position should be in an area for the best vibrati

Ar-Mite TM Low Flow Armored Flowmeter

Certificate of Compliance

AM54. Armored Variable Area Flowmeter Series AM54331/32 Series AM54371/72/73/74 Series AM54431/32 Series AM54471/72/73/74

Rosemount 2090F Hygienic Pressure Transmitter

Certificate of Compliance

Annubar Flowmeter Series

Rosemount 2090F Sanitary Pressure Transmitter with HART Protocol

Series 155. Mass Flow Computers TECHNICAL SPECIFICATIONS

ULTRA-SAFE Explosion-proof Duct Heaters

Ramsey Series Motion Monitoring Systems Accurate Sensing of Speed Conditions on Rotating Shafts and Machinery

Sitron s CF Line of Flow Switch Monitors

Rosemount 3100 Series Ultrasonic Level Transmitters

"ESDDR" Series Electric Humidifier

Instruction Manual Model A

Rosemount 3100 Series Ultrasonic Level Transmitters

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR PIPE THREAD IMMERSION HEATERS USED IN HAZARDOUS LOCATIONS

CERTIFICATE OF COMPLIANCE HAZARDOUS LOCATION ELECTRICAL EQUIPMENT PER CANADIAN REQUIREMENTS

Rosemount 3095MFC Compact Orifice Mass Flowmeter

CLARITY II TURBIDIMETER

TABLE OF CONTENTS Flow Detect 1000 Specifications 3 Description 4 Principle of Operation 4 Detection Through Walls 4 Sensing Beam Shape 4 Installation

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A

Rosemount 4500 Hygienic Pressure Transmitter. Start

Certificate of Compliance

UW Purchase Specification Section Steam Condensate or Hot Water Meter Page 1 of 9

MEAS CAL ALARM CONF APT2000 CC ENCLOSURE TYPE 2

Absolute and Gage Pressure Transmitter

Thermo Scientific Ramsey TM Series Sensing Speed Conditions on Rotating Shafts and Machinery

Certificate of Compliance

RF Admittance Technology FACTS

ULTRA-SAFE Explosion-proof Duct Heaters

EXCELLENCE in Solutions Products Service

DIGITAL METERS Large Display Temperature Meters Instruction Manual

vibration switch

Rosemount 2090P Pulp and Paper Pressure Transmitter

Oxygen (O2) Single-Point Gas Detection System

Multi-Spectral, Digital, Infrared Electro-Optical. FSC Model No. s. Unitized, Two Stage, Quick Response Flame Detectors.

Certificate of Compliance

Ramsey Motion Monitoring Systems

CR Series Command Relays

Pioneer-R16 Gas Monitor Operator s Manual

Rosemount 2100 Series

Schneider Electric Erie T155 Series

Model D12-IR. Digital Gas Transmitter...

Model 144H. Product Data Sheet , Rev DB February Content

SEC SIGNATURE ETO MONITOR TRAINING SENSOR ELECTRONICS CORPORATION

SAFETY MANUAL. Multispectrum IR Flame Detector X3301

Rosemount 2120 Vibrating Fork Liquid Level Switch

Rosemount 2120 Vibrating Fork Liquid Level Switch

Level Measurement Continuous level measurement Ultrasonic transmitters

D SYSTEM CONTROL DWG. APPROVED BY. OrCAD 6 ROSEMOUNT 2410

SEC Signature Process Gas Analyzer

Ring Detect Relays. Model RDR. Installation & Operation. Ph: \ \

MEAS CAL ALARM WASH CONF APT4000 CC ENCLOSURE TYPE 2

Certificate of Compliance

Model 6650SP. Filber Optic-Based UV-Fluorescence Oil-in-Water Analyzer

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

SNA-SKID Series - Preassembled Safety Shower Heater Skid Tankless Water Heating Solutions

PUV, PIR and PFO Series BROCHURE

Brooks MT3750 Low Flow Armored Flowmeter

Ring Detect Relays. Model RDR. Installation & Operation. Ph: \ \

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

Page. 1-2 Sepra-Lite Integral Optic Level Switches. 3-5 Electro Optic Level Systems: Probe and Controller

Rosemount 4500 Hygienic Pressure Transmitter

The Sub-Mini Hermet. OEM Pressure Switches Sub-Mini-Hermet and Omni

Model Q45P/R. ph/orp Monitor...

SAFETY MANUAL. X2200 UV, X9800 IR, X5200 UVIR SIL 2 Certified Flame Detectors

GG-EM ENTRANCE MONITOR. Installation and Operation Manual

YTA Series Temperature Transmitters [Style: S3] EN :2006, -11:2007, -26:2007. Supply circuit: Ui=30 V, Ii=165 ma,

WFDE Series Waterflow Detector

The Clark-Reliance Corporation TWIP System Installation and Maintenance Instructions - Form E112 -

ANNUNCIATOR INSTRUMENTS Model PD141AFO Instruction Manual

air.iq Moisture Analyzer Packaged Solution GE Measurement & Control Applications Features

Certificate of Compliance

Model Q45P/R. ph/orp Monitor...

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

Differential pressure gauge with electrical contact type Model: P650 series

Dräger Polytron 5100 EC Detection of toxic gases and vapors

MagMaster MFE flowmeters feature an innovative multifrequency

Certificate of Compliance

Transcription:

ULTRASONIC POINT LEVEL SYSTEM Introduction Compliance with growing government regulations mandates tighter level controls with advanced diagnostics to avoid releases, overspills and costly environmental clean-ups. Using anything but the most reliable and dependable point level switch for high level alarms and spill prevention has become unacceptable. Advancements in acoustical design and materials combined with Sensall Sapphire s patented Time-Gate technology have produced the most reliable and technically advanced level switch of its type. Sensall Sapphire performs exceptionally well in aerated, attenuative, viscous, corrosive, and even more severe applications. From the originators of the ultrasonic point level Gap switch technology, Sensall Sapphire is the industry standard for reliable point level measurements. Sensall took 30 years of level experience and developed Sapphire s unique measurement technique with superior selftesting capabilities. The continuous self-test feature automatically checks system integrity including electronics, sensor, and crystal disbonding, without the need for additional crystals or sensors mounted electronics. Sensall Sapphire s dual compartment housing provides quick and easy access to field wiring connections while protecting the electronics from exposure to harsh environments, damage, or leaky connections. During system installaion, electronics do not require removal and are safely protected while pulling wire and making field terminations. Sensall Sapphire systems carry Factory Mutual Research Corp. (FMRC) and Canadian Standars Asso. (CSA) approvals including Features & Benefits Single & Dual Point Systems Unmatched Reliability Superior Self-Testing Capabilities Variable System Qualification Time New Manual Loop Test Dual-compartment Housing (Single Point) Lowest Total Installed Cost Broad Range of Sensor Materials Broader Hazardous Location Approvals 3A Sanitary Finish and Fittings Dual Point Switch with completely independent electronics Dual point with up to 10 ft. or more separation Two Year Product Warranty NEMA 4X, intrinsically safe, explosion-proof, nonincendive, and dust/ignition-proof ratings. Installation and life cycle costs are reduced significantly with the use of loop powered intrinsically-safe outputs, elimination of poured seals at the electronics in Division 1 areas and elimination of rigid conduit and poured seals in Division 2 areas. A Thermo Electron business Thermo MeasureTech

Time Gate Technology Time Gate Technology starts by activating a transit crystal on one side of the measurement Gap and listening with a receive crystal on the opposite side. Since high frequencies of ultrasound travel readily through fluids but not air, liquid presence is determined by ultrasonic transmission within the measurement Gap. The signals from the receive crystal are analyzed at specific time intervals or windows controlled by the Time Gate. This method raises the system s sensitivity beyond the capabilities of previously available systems. Sapphire s patented Time Gate technology provides two important user benefits: 1. Reliable detection of the broadest possible range of process liquids including aerated, attentuative, viscous, corrosive, and more severe applications. 2. Self-tests are performed continuously and automatically. Sensall Sappire systems are available in either Gap or Slot configuration. Gap sensors perform exceptionally well in most applications, including aerated and attenuative liquids. The Slot s higher sensitivity provides reliable operation in even more severe applications. Continuous Self-Test Time Gate technology also incorporates a unique selftest function which it performed continuously and automatically. It verifies the system integrity including electronics, sensor and the crystal bond to the sensor body. Sensall Sapphire s self-test design does not involve the use of special self-test crystals or electronics inside the sensor probe. The simpler selftest design and the unique ability to detect disbonded crystals raises the level of Sapphire s dependability and reliability. System Qualification Time The System Qualification Time is the amout of time that process liquid must be continuously present or absent within the measurement Gap (in high-level operation) before the process alarm will be indicated. Sensall Sapphire qualifies that the new level condition is continuously present instead of a momentary occurence. This assures that the actual liquid level has reached the measurement Gap, instead of a wave fluctuation due to agitation or turbulence. Manual Loop Test The use of spill prevention devices such as Sensall Sapphire for high level alarms is on the rise. There are a number of environmental regulations that govern the overfill protection of above ground storage tanks (e.g., EPA, API, OSHA, etc.). In many cases, these regulations require written testing procedures, automatic verification, and on-demand testing of the complete spill prevention system. The Manual Loop Test is standard to verify field wiring, control integrity and operation of spill prevention systems without the need for filling tanks or costly system removal for testing. Manual Loop Test will change the outputs to the opposite state when the systems is not in the self-test or fault condition. The Manual Loop Test is momentarily activated as long as the Sensall supplied magnet is placed over the housing cover at the location marked Loop Test Materials and Mounting Gap sensors are available in a broad range of materials which include 316 stainless steel, Hastelloy C, Monel, Hastelloy B and Carpenter20. Slot sensors are available in 316 stainless steel only. Both the Gap and the Slot sensors can be delivered with a 150 grit (32 micro inch) or better, sanitary 3A finish and 316L stainless steel Tri-Clover (16 AMP) fittings that assemble and disassemble quickly for fast cleaning. Sapphire is the only ultrasonic point level system available with 3A symbol authorization. Sapphire systems are available with either 3/4 NPT mounting, various flange sizes, Tri-Clover fittings, or remotely mounted electronics. Sensall Sapphire Relay Operation The Sensall Sapphire relay models provide one Process relay for process level indication and a second Auxiliary relay for self-test fault indicationn. Both relays utilize gold plated contacts for reliable switching of lower current and voltage levels eliminating the need for DCS users to install interposing relays. Sensall Sapphire systems can be field selected for either high-level or low-level fail-safe operation. When high-level operation is selected, the Process relay is energized when the sensor is dry and de-energized when wet (e.g. in alarm). When low-level operation is selected, the Process relay is energized when the sensor is wet and de-energized when dry (e.g. in alarm). In both cases, the Process relay is always deenergized upon process alarm, self-test fault or power loss. The Auxiliary relay always de-energizes on self-test fault or power loss. The Auxiliary relay can be field selected to mimic the Process relay. When Mimic is selected, the Auxiliary relay will de-energize when a

In addition, the SPST Auxiliary relay output is field selectable for either NC or NO operation. Performance Specifications - Relay Operation Supply Voltage: 15-35 VDC (Electronics Model F) 115 VAC, ±10%, 50/60 Hz (Model G) 230 VAC, ±10%, 50/60 Hz (Model S) Power Consumption: 4 Watts maximum (2 Watts typical) Process Relay: SPDT relay with gold plated contacts. De-energizes on process alarm, self-test or power loss Maximum contact rating: 5 Amps at 115/250 VAC or 5 Amps at 30 VDC Minimum contact rating: 100 ma at 5 VDC or 15 ma at 24 VDC Auxiliary Relay: SPST (field selectable for either NC or NO operation) relay with gold plated contacts. De-energizes on selftest, power loss (and process alarm when mimic operation is field selected). Maximum contact rating: 5 Amps at 115/250 VAC or 5 Amps at 30 VDC Minimum contact rating: 100 ma at 5 VDC or 15 ma at 24 VDC Sensall Sapphire Two-Wire Operation The Sensall Sapphire two-wire, 4-20 ma DC model provides loop powered intrinsically-safe operation and lower installed costs to users with two-wire instrumentation. Two-wire systems use a fixed milliamp output to indicate process level (wet or dry sensor) and self-test fault. The wet and dry conditions can be indicated with either an 8 or 16 ma DC output. A self-test fault is indicated by an output of either 19 or 5 ma DC, depending on whether field selected for high-level or low-level operation, respectively. Performance Specifications - Two-Wire Operation: Supply Voltage: 12-55 VDC (Model J) Power Consumption: 1.1 Watt maximum Analog Ouput (±1 ma) 5 ma Self-Test Fault (low-level mode) 8 ma Dry, 16 ma Wet (field-selectable) 8 ma Wet, 16 ma Dry (field-selectable) 19 ma Self-Test Fault (high-level mode) Sensall Sapphire Relay and Two wire Operating Specifications Self-Test Feature Continuous. Automatically checks operation of electronics and sensor, including crystal bond to sensor body. Manual Loop Test: All output conditions momentarily change to the opposite state (except when in a fault condition) by placing the Sensall-supplied magnet (XB4353) over the housing covers at the location marked Loop Test. System Qualification Time: 0.3 to 12.0 seconds, field selectable Repeatability: ±0.1 inches Enclosure Dual-compartmetn NEMA 4X (ANSI 250 Type 4X) Enclosure 4 housing. Low copper aluminum; Polyurethane paint; Buna-N O-rings. Electrical Connections: Dual 1/2-inch NPT conduit connections. Wire range is 22 to 12 AWG. Operating Temperature Range: Electronics: -40 to 158 F (-40 to 70 C) Metal Sensors: -40 to 320 F (-40 to 160 C) -310 to 212 F (-190 to 100 C) Humidity: 10-95 RH, non-condensing Weight (with 3/4 NPT, 1.0 inch A dimension): 4 lbs. (1.8 Kg) Current Loop Loads: Rload, max = (V supply-12) x 50 Ohms

SENSALL SAPPHIRE ENCLOSURE DIMENSIONS Sensall Sapphire 4.25 (108.0) 4.10 (104.1) STAINLESS STEEL CUSTOMER TAG (OPTIONAL) 1/2 NPT (2 PLACES) 0.69 (17.5) Place Loop Test Magnet Here 6.60 (167.6) NOTE 2 CONNECTION SIDE 6.15 (156.2) APPROVAL LABEL (IF APPLICABLE) PRODUCT IDENTIFICATION LABEL Circuit Side NOTES: 1. Dimensions are in inches (millimeters), nominal, and are for reference only. 2. Dimensions increase in 3 inches (76.2 mm) with installation of optional thermal isolator (3/4 NPT fitting only). SENSALL SAPPHIRE SENSOR DIMENSIONS STANDARD GAP SENSOR STANDARD SLOT SENSOR TRI-CLOVER GAP SENSOR A DIMENSION A DIMENSION A DIMENSION 1.44 (36.6) 2.75 (69.9) 1.44 (36.6) 0.88 (22.4) DIA 0.94 (23.9) 0.88 (22.4) DIA 0.30 (7.6) 0.88 (22.4) DIA 0.94 (23.9) NOTES: 1. Dimensions are in inches (millimeters), nominal, and are for reference only. 2. Dotted lines represent optional fitting & flange types. 3. Total sensor length is equal to the A Dimensions plus the remaining sensor length.

Factory Mutual (FM & Canadian Standards Association (CSA) Approved): Explosion Proof: Class I, Division 1, Groups B (FMRC only ), C, & D Intrinsically Safe (Entity) Class I, Division 1, Groups A, B, C, & D. T4 Temperature cods (135 C) when installed in accordance with I/S wiring diagram of Instruction Manual, section 4, page 4-4. Entity parameters: Vmax = 55V, Imax = 118 ma, Ci = 0.024uF, Li = 0 mh. Dust/Ignition Proof: Class II, Division 2, Groups E, F, & G Class III, Hazardous Locations Sensor Style Gap Non-incendive: Class I, Division 2, Groups A, B, C, & D. T4A Temperature Code (120 C) Suitable for Class II, Groups E & G. Suitable for Class III, Hazardous Locations Remote sensor and field wiring are approved as N/I field wiring when installed in accordance with Class I, Division 2 wiring diagram of Instruction Manual Indoor/Outdoor Use: NEMA 4X (ANSI 250 Type 4X) Enclosure 4 Stainless Steel Tagging Each Sapphire can be labeled with up to 15 characters of user-specified 1/16 text located on the product s identification label. An optional stainless steel tag (part #620-000530), located on top of the electronics housing, can provide four lines of 1/8 text (two lines for remote systems) with a maximum of 24 characters per line. Slot Materials of Construction Carpenter 20 Hastelloy C Monel Hastelloy B 316SS 316 SS Min. Sensor A Dimension 1 inch (25 mm) 4 inches (102mm) Max. Sensor A Dimension Remaining Sensor Length Sensor Operating Temperature 1 Maximum Operating Pressure 2 Proof Pressure 2 120 inches (3,048 mm) 1.44 inches (36.6 mm) -40 to 320 F (-40 to 160 C) -310 to 212 F (-69 to 100 C) -10 to 1,000 psig (-69 to 6,895 KPa) 1,500 psig (10,342 KPa) 120 inches (3,048 mm) 0.30 inches (7.6 mm) -40 to 320 F (-40 to 160 C) -310 to 212 F (-190 to 100 C) -10 to 1,000 psig (-69 to 6,895 KPa) 1,500 psgi (10,342 KPa) NOTES 1. The Thermal Isolator is required for 3/4 NPT unit when process temperatures exceed 275 F (135 C). Flanged and remote mounted units do not require the use of the Thermal Isolator. 2. Pressure ratings are for 3/4 NPT units. NOTES 1. Order in 5/10 inch or 10 millimeter increments, because manufacturing tolerances are ±2/10 inch (±5 mm) for metal sensors. 2. When specifiying sensor lengths, be sure to take into consideration that the total installed sensor length is equal to the A dimension plus the remaining sensor length. 3. Tri-Clover fittings are available with integral mounted Sapphire systems only; Tri-Clover fittings are not available with remote mounted systems. A 1 Tri-Clover is the same size as a 1-1/2 Tri-Clover fitting.

SENSALL SAPPHIRE INTEGRAL MOUNT PRODUCT NOMENCLATURE Code F C G Remote Electronics Factory Mutual (FM) Approved Canadian Standards Association (CSA) certified Non-approved units Code Electronics J F G S 12-55 VDC input, 4-20 ma (intrinsically safe/ep/dip/ni) 15-35 VDC input, Relay output, NO or NC user-selectable Auxiliary Fault Relay 115 VAC input, Relay output, NO or NC user-selectable Auxiliary Fault Relay 230 VAC input, Relay output, NO or NC user-selectable Auxiliary Fault Relay Code O T Sensall Sapphire Mounting Configuration Integral electronics and Sensor Thermal Isolator (required for 3/4 NPT units with process temperatures above 275 F (135 C) Code Sensor Type G Gap S Slot (316SS Only) Code Sensor Material (See Notes 1 and 5) S 316 Stainless Steel (Gap & Slot) H Hastelloy C (Gap only) U Monel (Gap only) B Hastelloy B (Gap only) Q Carpenter 20 (Gap only) Code Measurement for A Dimensions (See Note 2) T Inches, 0.5 increments M Millimeters, 1.0 mm increments Code Sensor A Dimensions ( See Notes 2 & 3) #### Sensors are available in 0.5 inch increments only 0010-1200 for Gap Sensors (e.g., 0010 is 1.0 inch) 0040-1200 for Slot Sensors (e.g., 1200 is 120.0 inches) #### Sensors available in 10 millimeter increments only 0025-3048 for Gap Sensors (e.g., 0025 is 25 millimeter) 0102-3048 for Slot Sensors (e.g., 3048 is 3048 millimeter) Code Fitting / Flange (See Note 4) N 3/4 NPT (material same as sensor F Flange 150 lb. ANSI Raised Face (Metal same as sensor) G Flange 300 lb. ANSI Raised Face (Metal same as sensor) T Tri-clover (16 AMP) sanitary fitting & 150 grit polished sensor Code Fitting / Flange Size 00 3/4 NPT only 10 1 Flange/Tri-clover 15 1-1/2 Flange / Tri-clover 20 2 Flange / Tri-clover 25 2-1/2 Tri-clover only (Flange not available) 30 3 Flange / Tri-clover 40 4 Flange / Tri-clover 60 6 Flange only (Tri-clover not available) Code Fitting / Flange Material (See Sapphire Ref. Notes 1 & 4) S 316 Stainless Steel (Gap & Slot) H Hastelloy C (Gap only) U Monel (Gap only) B Hastelloy B (Gap only; consult factory for availability) Q Carpenter 20 (Gap only; consult factory for availability) V 316L Stainless Steel (Tri-Clover fitting only) F G O G S T 0060 N 00 S Typical Integral Nomenclature 103-100031 10/01 Thermo MeasureTech Austin 2555 North IH 35 P.O. Box 800 Round Rock, Texas 78680-0800 512-388-9100 800-736-0801 (v) 512-388-9200 (f) Thermo MeasureTech Canada 14 Gormley Industrial Avenue, Unit 14 Gormley, Ontario LOH 1G0 905-888-8808 (v) 905-888-8828 (f) www.thermomeasuretech.com sales@thermomt.com Thermo MeasureTech Chicago 1400 Business Center Drive, Suite 100 Mt. Prospect, IL 60056 847-803-5100 800-323-7594 (v) 847-803-5466 (f)