For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

Similar documents
RG7D 1-Stage Heat Series

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

G6RC Series TECHNICAL SPECIFICATIONS

FG7T (C and L Series)

TECHNICAL SPECIFICATIONS

FG6T(C,L) Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

KG6TE Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS

RE9X Series Downflow, Upflow Electric Furnaces

E4EB-xxx-H Series Downflow, Upflow Electric Furnaces

E3EB-xxx-H Series Downflow, Upflow Electric Furnaces

E2 Series. Downflow, Upflow Electric Furnaces TECHNICAL SPECIFICATIONS. Features and Benefits

E3EH-xxx-H Series E3EB-xxx-H Series

Comfort, Quality and Efficiency.

TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE DESCRIPTION WARRANTY FEATURES

GAS FURNACES CLASSIC 90 PLUS HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES

Rheem Classic Series Downflow/ Horizontal Gas Furnaces

W92P- SERIES Models with Input Rates from 40 to 115 kbtu [11.72 to kw] (92% A.F.U.E. )

COMFORT CONTROL 90 PLUS WITH DUAL TWO-STAGE UPFLOW GAS FURNACES

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama ! WARNING

HIGH-EFFICIENCY FURNACES

GAS FURNACES. RGRK- SERIES Models with Input Rates 120,000 BTU/HR [35.17 kw] (All Models 90% A.F.U.E. or Above)

80% Variable Speed, Two Stage Heating Furnace. Cooling Capacity CFM in. w.c. (125 Pa)

HIGH EFFICIENCY FURNACES Built Exclusively for Manufactured Housing

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

GAS FURNACES SELECT 90 PLUS HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

Ruud Acheiver Series Upflow Gas Furnaces

Energy Saving. Space Saving.

Model GB1AAV UPFLOW GAS FURNACE. Series G SS-GB1A-04 FEATURES

TZ96MDP SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 96% A.F.U.E. )

90 HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES

90 HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES

90TJ SERIES Models with Input Rates from 45,000 to 120,000 BTU/HR [13.19 to kw] (All Models 90% A.F.U.E. or Above)

GAS FURNACES SUPER QUIET 80 TWO STAGE 80% A.F.U.E. DOWNFLOW GAS FURNACES

GAS FURNACES. ACHIEVER SERIES SUPER QUIET 80 80% A.F.U.E. DOWNFLOW GAS FURNACES w/ecm MOTOR

Multi-Position Gas Furnaces

G I E TECHNICAL GUIDE 95.5% AFUE SINGLE STAGE RESIDENTIAL GAS FURNACES MULTI-POSITION MODELS: TG9S DESCRIPTION FEATURES WARRANTY SUMMARY

Rheem Classic Plus Series Two Stage Multi position Gas Furnaces

MERIT SERIES Downflow

FORM NO. G REV. 4 Supersedes Form No. G Rev. 3

MULTI POSITION GAS FURNACE

GAS FURNACES CLASSIC 95% A.F.U.E. HIGH EFFICIENCY UPFLOW GAS FURNACES

GMS95 GAS $AVER PRODUCT SPECIFICATIONS 95% AFUE. Multi-Position, Single-Stage/Multi-Speed Gas Furnace. Heating Capacity: 46, ,000 BTUH

GAS FURNACES CLASSIC 90 PLUS HIGH EFFICIENCY UPFLOW GAS FURNACES

Rheem Classic Series Multi-position Gas Furnaces

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

TZ95MSX SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 95% A.F.U.E. )

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

Residential/Commercial Gas Condensing Tankless Models

GAS FURNACES 90 PLUS WITH DUAL COMFORT CONTROL TWO-STAGE UPFLOW GAS FURNACES

MULTI-LINK UP TO 20 UNITS COMMON VENT UP TO 8 UNITS COMPLIES WITH LEAD FREE STANDARDS SAFETY FEATURES:

Upflow/Horizontal Left, Downflow/Horizontal Right Two Stage Condensing Gas-Fired Furnace

Ruud Achiever Series Multi position Gas Furnaces

TECHNICAL GUIDE MODELS: P*UR GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW FURNACES 92 AFUE DESCRIPTION WARRANTY FEATURES Rev.

Ruud Achiever Plus Series Multi-position Gas Furnaces

GAS FURNACES. Communicating Furnace Thermostat. FORM NO. G Supersedes Form No. G RHC-TST550CMMS MID HIGH

Rheem Classic Plus Series Multi position Gas Furnaces

FEATURES. Gas Furnace provides the efficiency customers want with 78% Annual Fuel Utilization Efficiency (AFUE).

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh

MULTI POSITION GAS FURNACE

TZ96MDV SERIES Model with Input Rates from 60 to 100 kbtu [17.58 to kw] (All Models 95% A.F.U.E. )

Downflow/Horizontal Condensing, Gas-Fired Furnace XB 90 PUB. NO

Downflow/Horizontal Right Induced Draft Gas Furnace

FORM NO. G REV. 2 Supersedes Form No. G Rev. 1 GAS FURNACES

Series Two- Stage Multi-position Gas Furnaces. Ruud Achiever Plus. R96T- Series 96% A.F.U.E. * Input Rates from 40 to 115 kbtu [11.72 to 33.

Rheem Prestige Series Two-Stage Downflow Gas Furnace equipped with the Comfort Control 2. System. RGLE- Series 80% A.F.U.E. Input Rates kbtu

80% A.F.U.E. DOWNFLOW GAS FURNACES

COMPACT UNIT HEATERS Low Profile - Horizontal - 60 HZ. Steady-State Efficiency - up to 81% Input - 30,000 to 75,000 Btuh

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

GMS9/GCS9 SERIES 93% AFUE

Upflow/Horizontal Condensing, Gas-Fired Furnace XB 90 PUB. NO

ELITE SERIES Downflow - High Efficiency Blower Motor

Rheem Prestige Series Communicating Two Stage Variable Speed Multi position. Gas Furnaces

Rheem Prestige Series Communicating Two Stage Variable Speed Multi position. Gas Furnaces

Wt. Lbs Model Number (BTUH) Hz

GAS FURNACES. RGFD- SERIES Models with Input Rates from 60,000 to 120,000 BTU/HR [17.58 to kw] (All Models 92% A.F.U.E.

Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace XR 80

Upflow/ Horizontal Left, Downflow/ Horizontal Right Two Stage Condensing Gas-Fired Furnace XL 90

GAS FURNACES. RGFD- SERIES Models with Input Rates from 60,000 to 120,000 BTU/HR [17.58 to kw] (All Models 92% A.F.U.E.

VNE GAS FURNACE 2- STAGE VARIABLE SPEED UPFLOW/HORIZONTAL

GAS FURNACES SILHOUETTE II PLUS 2 LXE TWO STAGE 80% A.F.U.E. UPFLOW/HORIZONTAL GAS FURNACES

GAS FURNACES. Visit taxcredit for complete details.

Upflow/Horizontal 2-Stage, Communicating Variable Speed Gas Furnace Platinum SV

G71MPP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

Multi-Position Gas Furnaces

Air-Fuel Ratio (AFR) Sensor Exhaust & Water Temperature Safety Control Overheat Cut-Off Fuse

Cooling Capacity CFM in. w.c. (125 Pa)

Rheem Prestige Series Communicating Two-Stage Variable Speed Downflow Gas Furnace

Rheem Prestige Series Modulating Horizontal Gas Furnace equipped with the Comfort Control 2. System

Tankless Condensing High Efficiency Water Heaters with Built-In Pump

GAS FURNACES 90 PLUS COMMUNICATING MODULATING UPFLOW GAS FURNACES EQUIPPED WITH THE COMFORT CONTROL 2 SYSTEM AND CONTOUR COMFORT CONTROL

Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace XR 80

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

GME8 80% AFUE. Multi-Position, TwinComfort. Heating Input: 60, ,000 BTU/h

Upflow/Horizontal Condensing, Gas-Fired Furnace

Transcription:

TECHNICAL SPECIFICATIONS M7RL Series High Efficiency / Direct Vent Condensing Downflow Gas Furnace Induced Draft - 95%+ AFUE Input 45,000 thru 7,000 Btuh The high efficiency downflow gas furnace is especially designed for Modular Housing. It may be installed in a utility room, or enclosed in a closet. CSA design certified for use in the United States and Canada. BW Models For More Information Click Here or Call General Supply 1-844-647-8673 BWT Models FEATURES and BENEFITS 100% fired and tested: All units and each component (both mechanical and electrical) are tested on the manufacturing line. Clean and quiet operation: Due to the unique design of in-shot burners, location of inducer and use of insulation. Fixed 30 second blower delay: At burner start-up assures a warm outlet air temperature at furnace start-up. Adjustable blower off settings (60, 90, 10 and 180 seconds). Fixed 30-second post purge: Increases life of heat exchanger. Dependable, hot surface ignitor: Innovative application of silicon nitride type igniter. Utilizes proven Smartlite technology. Tubular primary heat exchanger: Heavy gauge aluminized steel heat exchanger assures a long life. Stainless steel secondary heat exchanger: Assures a long life. 90 second fixed cooling cycle blower-off delay (TDR): Increases cooling performance when matched with a NORDYNE coil. Sealed combustion approved for direct vent furnace, category IV venting system: May be vertically or horizontally vented using a two-pipe system for maximum flexibility in installation. LP convertible: Simple burner orifice and gas valve regulator change for ease of convertibility. 3 amp fuse protection against low voltage shorts: Protects transformer and control board. Low voltage terminal board: For easy field wiring. Easy open pawl latch: Secures the door firmly for transit, yet allows easy removal for access. Appliance quality door: Protects against rust and other corrosion. Baked enamel finish allows for easy cleaning. Fully insulated cabinet: Insures minimized heat loss and quiet operation. Color coded wire harness: Designed to fit the components, all with quick-connect fittings for ease of service and replacement. Multi-speed direct drive blower: Designed to give a wide range of cooling capacities. Switches on PCB, provide ultra easy motor speed selection. 40VA transformer included. Diagnostic lights for easy troubleshooting without counting flashes: Dedicated light for flame signal strength and lights in combination to indicate all other fault codes with easy to recognize states without counting flashes. Note: The M7RL will fit in the same footprint and uses the same duct connector as the M1 & M3 funaces. The design of the M7RL allows for direct substitution in place of the M1 & M3 series furnaces.

FEATURES High Efficiency Downflow 95% AFUE + Gas Furnace Downflow Furnace Exhaust Vent Pipe Blower Switch Blower Assembly Control Board Inline Drain Assembly Limit Switch Gas Valve Igniter Inducer Assembly Combustion Air Pipe 4V Transformer Main Air Limit Switch Flame Sensor Roll-Out Switch Gas Manifold & Burner Assembly ALT. FUEL LINE HOLES CL SIDE WALL FUEL LINE HOLE REAR WALL 10" C L FLOOR OPENING 3-1/4" Alcove M7RL B Cabinet Shown SPECIFICATIONS M7RL MODEL NUMBERS: 045A 060A 07A Input (BTUH)* 45000 60000 7000 Heating Capacity (BTUH) 4750 57000 68400 AFUE (%) 95.1 95.1 95.1 Blower D x W (in.) 11 x 8 11 x 8 11 x 8 Motor HP-Speed-Type 1/ - 4 - PSC 1/ - 4 - PSC 1/ - 4 - PSC Motor FLA (Amps) 8.60 8.60 8.00 Rated Ext. SP (in. WC) 0.3 0.3 0.3 Temperature Rise Range ( F) 5-55 5-55 30-60 Fuse or Breaker (Amps) 0 0 Note: All models are 1V, 60 Hz, 1 phase. Gas Connections are 1/ NPT. AFUE = Annual Fuel Utilization Efficiency * Ratings to,000 ft. Over,000 ft. reduce 4% for each 1,000 ft. above sea level. STANDARD EQUIPMENT Direct vent; draft inducer; pressure switch; redundant main gas control; hot-surface ignition; timed ON/OFF blower controls (TDR); 40VA transformer for air conditioner application; limit controls; direct drive motor; all models can be converted to use LP (propane) gas. Shipping Weights Furnace Model Shipping Weight (lbs) M7RL 045A AW 0 M7RL 045A BW* 170 M7RL 060A AW 0 M7RL 060A BW* 170 M7RL 07A AW 5 M7RL 07A BW* 175 *May include suffix - T

DIMENSIONS 1 17 3/4 1/ 1/ x 5 (Ventilaire) 3 1/ (X) 5 5/8 3/4 3 1/ 1 1/ 1 1/ 0 1/4 17 1/8 7/8 (Electric) 3/4 56 1 1/ X 3 1/ 3 1/ 1 1/ X 3 1/ 1 3/16 1 3/16 3 1/ 4 5/8 0 1 7/8 1 1/ X 3 1/ (Gas or Condensate - Typical) 1/ TYP. 1 5/8 TYP. 3/8 1 1/8 CLOSET ALCOVE ALL MODELS Inches Inches Front 1* 1* Back 0 0 Sides 0 0 Vent 0 0 Top 6 6 Duct (Plenum) w/ Coil Box 0 0 w/o Coil Box (within 3 feet) 1/4 1/4 *Note: For 1" clearance, use a fully louvered door with at least 400 square inches of free airflow area. Minimum Clearances AW Models 3

DIMENSIONS BW Top BWT Top 1 17 3/4 19 3/4 17 1/ 1/ x 5 (Ventilaire) 3 1/ (X) 3 1/ (X) 1/ x 5 (Ventilaire) 1/ 5 5/8 1/ 1/ 3/4 3 5/8 5 5/8 1 1/ 3/4 1 1/ 3 1 1 ckouts (x4) 1 1/ 1 1/ 0 1/4 0 1/4 18 1 7/8 ectric) 3/4 7/8 (Electric) 3/4 17 1/8 55 17 1/8 55 76 76 3 1/ 43 1/ 3 1/ 43 1/ 1 7/8 1 7/8 1/ X 3 1/ r Condensate) 1 1/41 1/ X 3 1/ 1 1/4 0 0 1.50 1 1/ X 3 1/ 1.50 1 1/ X 3 1/ 4 5/8 4 5/8 19 3/4 19 3/4 1 1/ X 3 1/ (Gas, Condensate, or Linesets - Typical) 1 1/ X 3 1/ (Gas, Condensate, or Linesets - Typical) 1 1/ X 3 1/ (Gas or Condensate - Typical) 1/ TYP. 3/8 1 1/8 1 5/8 TYP. 3/8 1 1/8 1 5/8 TYP. 1 5/8 TYP. CLOSET ALCOVE ALL MODELS 3/8 1 Inches 1/8 Inches Front 1* 1* Back 0 0 Sides 0 0 Vent 0 0 Top 6 6 Duct (Plenum) w/ Coil Box 0 0 w/o Coil Box (within 3 feet) 1/4 1/4 *Note: For 1" clearance, use a fully louvered door with at least 400 square inches of free airflow area. Minimum Clearances BW Models 4

BLOWER PERFORMANCE Model Number & Heating Input (BTUH) M7RL 045 45,000 M7RL 060 60,000 M7RL 07 7,000 Motor Speed External Static Pressure (Inches Water Column) 0.1 0. 0.3 0.4 0.5 CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise Recommended A/C Ton HIGH* 80 5 30 6 1485 7 1435 8 1380 9 4 MED HIGH 1355 9 1330 30 1300 30 165 31 10 3 3 MED LOW 1185 33 1165 34 1140 35 1100 36 1065 37 1/ LOW** 910 44 890 45 865 46 835 47 810 49 HIGH* 80 33 30 35 1485 36 1435 37 1380 38 4 MED HIGH** 1355 39 1330 40 1300 41 165 4 10 43 3 MED LOW 1185 45 1165 45 1140 46 1100 48 1065 50 1/ LOW 910 58 890 59 865 61 835 63 810 65 HIGH* 55 41 05 4 1460 43 1405 45 1350 47 4 MED HIGH** 1490 43 1450 44 1405 45 1355 47 1310 48 3 MED LOW 1005 63 975 65 950 67 95 69 875 7 1/ LOW 900 70 875 7 845 75 810 78 775 8 * Factory Set Cooling Speed ** Factory Set Heating Speed 1. Temperature rises ( F) in the table are approximate. Actual temperature rises may vary.. Temperature rises shaded in gray are for reference only. These conditions are not recommended. 3. Airflow performance is with a filter. ACCESSORIES Description Part Number Automatic Cavity Damper 901083 "VEE" Box Adapters (10") - 5 / carton 901985 "VEE" Box Adapters (1") - 5 / carton 90149 A/C Coil Box 911969A Side Return Air Kit 904003 Concentric Vent Termination Kit (for horizontal and vertical venting) 904953 Horizontal Exterior Vent Mounting Kit 3"PVC 90375 Neutralizer Kit - All Models 90377 PVC Isolation Kit 904063 Vent Transition Kit 904106 5

ACCESSORIES (cont.) ACCESSORY VENT KITS Vent Kits Part Number Soffit Air Inlet (for VentilAire III only) 91701 VentilAire III - Sloped 3/1 914098 VentilAire IV - Sloped 3/1 9149 IDENTIFICATION CODE Application M-Modular Home Furnace Series Comfort Model RL - Condensing Downflow M 7 R L (045) A - A W Heating Capacity Input, BTUH (000 ) Return Air Configuration Blank - Front T - Top Door Color W - White Cabinet Dimensions A - 56" x 19-3/4" x 3-3/4 B - w/coil Cavity, 76" x 19-3/4" x 3-3/4" Electrical Code A - 1PH, 60 Hz, 10 VAC 6

VENTING All models are approved for both vertical and horizontal direct ( pipe) venting applications. See Vent Table below for specified sizes and allowable lengths. Maximum Direct Vent, Dual Pipe Length (ft.)* M7RL Inputs (BTUH) Inlet / Outlet 3 in. Diameter 45,000 60 60,000 60 7,000 60 *NOTES: 1. Subtract 3.5 ft. for each additional 3" 90 degree elbow.. Two 45 degree elbows are equivalent to one 90 degree elbow. 3. One short radius elbow is equivalent to two long radius elbows 4. Do not include termination elbows in calculation of vent length 5. This table is applicable for elevations from sea level to,000 ft. For higher elevations decrease vent pipe lengths by 8% per 1000 ft. of altitude. 6. Only the listed pipe materials are approved for use with M7 condensing furnaces. 7. For Canadian applications, use ULC S636 approved material. Pipe Materials Schedule 40PVC PVC-DWV SDR-1 & SDR-6 ABS-DWV Schedule 40 ABS Foam / Cellular Core PVC ANSI/ASTM Standard D1785 D665 D41 D661 F68 F891 7

GENERAL TERMS OF LIMITED WARRANTY NORDYNE will furnish a replacement for any part of this product which fails in normal use and service within the first year of installation, in accordance with the terms of the warranty. For complete details of the Limited Warranty, including applicable terms and conditions, see your local installer or contact the NORDYNE warranty department for a copy. 718D-0511 (Replaces 718D-0411) General Supply Inc. Toll Free: (800)-479-754 Specifications and illustrations subject to change without notice and without incurring obligations. Printed in U.S.A (05/011)