YARWAY PROCESS THERMODYNAMIC STEAM TRAPS SERIES 40/40D AND C250/260

Similar documents
The right trap for the right application.

Series 151 and AV5. A wide range of process thermostatic steam traps is available to match almost any application need.

YARWAY PROCESS THERMOSTATIC STEAM TRAPS SERIES 151 AND AV5

Yarway Repairable Drip and Tracer Steam Traps Series 751/761, 711/721, 731/741, 500/546, 460/515/D3

Economical and simplified solutions that offer quality and optimum steam trap service.

YARWAY NON-REPAIRABLE DRIP AND TRACER STEAM TRAPS SERIES PB, 29, 129Y AND 29S

Wide range of steam traps that provide consistent performance in less than perfect conditions.

NICHOLSON STEAM TRAP THERMODYNAMIC STEAM TRAPS

Yarway Narvik Steam Desuperheater Series 4300 TempLow

THERMOSTATIC STEAM TRAPS

FT600 & FT601* Steam Traps Float & Thermostatic Steam Trap. Float & Thermostatic STEAM TRAPS

Liquid Drainers LIQUID DRAINERS

LIQUIDATOR UMT-TD Series Thermodynamic

THERMODYNAMIC STEAM TRAPS

PT15 MATERIAL : DIMENSIONS - Nominal in inches. AVAILABLE SPARES: Disc (Packet of 5) ORDERING INFORMATION: Refer to "HOW TO ORDER" page.

STEAM TRAPS

THE THERMOSTATIC STEAM TRAP

THERMODYNAMIC STEAM TRAPS

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD

TABLE OF CONTENTS STEAM TRAPS INVERTED BUCKET SERIES PAGE FLOAT AND THERMOSTATIC SERIES PAGE THERMOSTATIC THERMODISC B0 26. How to Select All 107

LIQUIDATOR 450 SERIES

Hoffman Specialty General Catalog

Mini Pump Trap. Features: n Low maintenance - No leaking seals, impeller or motor problems reducing maintenance and downtime.

Bringing Energy Down to Earth

Armstrong J Series Float, Thermostatic Steam Traps, Condensate Controllers & Liquid Drainers Installation and Maintenance Manual

WHY THE REMOVAL OF NONCONDENSABLE GASES AND AIR IS CRITICAL IN A STEAM SYSTEM

Float & Thermostatic Steam Traps for efficient condensate drainage of industrial process and HVAC equipment

BASICS OF STEAM TRAPS BASICS OF STEAM TRAPS

THERMODYNAMIC STEAM TRAP

Inverted Bucket Float & Thermostatic Radiator Traps STEAM CONTROL PRODUCTS STEAM TRAPS

Steam Conservation Guidelines for Condensate Drainage Steam Trap Sizing and Selection.

ESCO. Committed. Group of Companies. to help conserve Steam Energy

Steam Traps and Steam Specialties

Hydrocarbon & Chemical Processing Solutions

STEAM CONSERVATION GUIDELINES

Product. Add Efficiency To Your Steam Investment... Steam Traps Drain Traps Air Vents & Eliminators Accessories Piping Assemblies Replacement Kits

Chapter 2.3: Steam System

Steam Trap Presentation for IDEA Distribution Workshop. Presenter: Joe Radle

Armstrong Steam System Solutions for the Hydrocarbon and Chemical Processing Industries

PIP PNE00004 Steam Trap Guidelines

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT

Steam Conservation Guidelines for. Drainage. Mead O'Brien (800) LP Steam. Condensate. HP Steam RECEIVER TANK HEATER

Ball Float Controlled. Thermo Dynamic(TD) Trap Safety Valve Condensate Pump Flash Vessel Moisture Separators Deaerator Head Steam Injector Sight Glass

APT and APT14 Automatic Pump Traps. for effective condensate drainage and removal

Steam Traps. . Chambered valves such as; bleeding & venting valves and steam traps. Float Valves using a free fl oat

Inverted Bucket Steam Traps. for efficient condensate drainage of industrial and HVAC equipment

How to Trap: Rotating Dryers Requiring Syphon Drainage

How to Trap: Trap Selection and Safety Factors

Essex County College - West Essex Campus Addition And Renovations dib # / SECTION HYDRONIC PIPING SPECIALTIES PART 1- GENERAL

Silhouette. Feedwater Heater. Boiler Feedwater

How to Trap: Process Air Heaters

Removal of Non-condensable Gases and Air Is Critical In A Steam System

Catalog. Self-operated Regulators Volume 2 Temperature Regulators

Main Steam Vents. Hoffman Specialty Regulators. How to Select Steam Vents

ø D ø g ø k Max. service [barg] pressure [psig] H 1 96 L BK 45 with butt-weld ends End connections Screwed Socket-weld

UNIVERSAL STYLE STEAM TRAPS WU450 Series

FLOAT AND THERMOSTATIC STEAM TRAPS FLT17 (DN 1/2 to 1 ; DN15 to DN25)

opening trap 30 mm Space required for Space required for opening trap 30 mm MK 45-1 with flanged ends (to DIN)

UFGS (May 2010) UNIFIED FACILITIES GUIDE SPECIFICATIONS

How to Trap: Steam Tracer Lines

Armstrong Steam System Solutions for the Hydrocarbon and Chemical Processing Industries

Condensate Pumps Jones Boulevard Limerick Airport Business Center Pottstown PA Tel:

KEEP YOUR TRAP SHUT OR GET THE CONDENSATE OUT

Pumps. Pressured-powered pump catalog. The more reliable and efficient way to pump condensate and other liquids.

Installation, Operation and Maintenance Guide. Steam Coil Installation, Operation and Maintenance. steam coils

Steam Site Guide. Steam Site Guide. Heat Exchange Applications - SI Units

S and SF Inverted Bucket Steam Traps Installation and Maintenance Instructions

Air Vents AV-392. Proven Same proven, free-floating all stainless steel mechanism as used in Armstrong steam traps.

Our Know-How. Your Peace of Mind. Steam Solutions

INDUSTRIAL HEAT EXCHANGERS

UNIFIED FACILITIES GUIDE SPECIFICATIONS

VENTS. Main Steam Vents. How to Select Steam Vents. For Steam Vent selection information, please refer to Selection Guidelines on page 133.

COMMERCIAL ITEM DESCRIPTION TRAPS, STEAM

Pump & Trap Combinations

Installation and Maintenance "L" and "LS" Series

International Reactor Bulletin 1100 Corporation. Standard and Custom Reactors for the Chemical Process Industries

MODELS N150/300/675/900/1500/2500/2600 INSTALLATION, SERVICING AND MAINTENANCE INSTRUCTIONS

SECTION REFRIGERANT PIPING

INSTALLATION, OPERATION

Model AV Alarm Valve With and Without Model RC-1 Retard Chamber European Conformity Valve Trim General Description

TECHNICAL DATA. Wet 26a. February 22, 2009

Steam Trap Selection

D-8 OUTLINE SPECIFICATION FOR HTHW HEAT EXCHANGERS

CD-33/CD-33S Controlled Disc Steam Traps

Technical Data CONDENSATE COMMANDER PUMP SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 9902D

HEAT GENERATION 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS. B. Section HVAC Basic Materials and Methods

Documento Descargado desde:

A. This Section includes the following domestic water piping specialties:

How to Trap: Troubleshooting

Series 1140 and 1141 Temperature Regulators

MFP14 Automatic pumps for condensate and other industrial fluids

MAXIFLO EJECTOR SYSTEM AN INNOVATIVE APPROACH TO STEAM CONSERVATION LEVEL 4 BEE ACCREDITED

Steam trap checking WHY WE NEED TO CHECK STEAM TRAPS METHODS OF CHECKING TRAPS ADVANTAGES AND DISADVANTAGES PRACTICAL DEMONSTRATION

Pamphlet A2404. Mechanical Pump & Pump/ Trap. GP Series GT Series

SERVICE MANUAL. For Service & Parts please call APK THERMAL at or SAFETY INSTRUCTION

High Capacity Instantaneous Steam Fired Water Heater

Inverted Bucket Steam Traps

Oil burners fuel unit with solenoid valve

MFP14 Automatic pumps. for condensate and other industrial fluids

AIR CONDITIONING. Carrier Corporation 2002 Cat. No

Transcription:

SERIES 40/40D AND C250/260 Designed for a variety of high pressure and high capacity applications found in utility, industrial and marine service FEATURES Designed to fail open. Designed for superheat steam. Unaffected by corrosive condensate, freezing and water komma. In-line maintenance. Designed to response to load charges. Excellent air handling. Small lightweight design. Performance testing per ASME PTC-39.1, ISO 7841 and 7842. GENERAL APPLICATION For condensate removal in high pressure industrial and steam systems. The C250 is typically smaller than other mechanical traps for high pressure applications. TECHNICAL DATA TECHNOLOGY: THERMODYNAMIC PISTON AND LEVER Size: NPS ½, ¾, 1, 1½,2,3 DN 15, 20, 25, 40, 50, 80 Temperature: Max. design 750 F [400 C] Pressure rating: 2 to 1500 psig [0.14 to 103 bar] Capacity: Up to 80,000 lb/hr [36,000 kg/hr] Connections: Socket weld, Threaded, Flanged Materials: Chrome moly Emerson.com/FinalControl 2017 Emerson. All Rights Reserved. VCTDS-02343-EN 15/06

GUIDELINES FOR TYPICAL PROCESS APPLICATIONS Depending on the application, a process steam trap will probably have to handle heavy startup loads, often followed by smaller running loads. The trap s function is to drain the process equipment and thus ensure that effective heat transfer is achieved (through latent heat). A few guidelines for optimum results include: Provide an adequate size process connection from equipment. Locate trap below the equipment (water runs downhill). Use good piping practice to ensure that clean condensate is presented to the trap. Include air vents and vacuum breakers as necessary for effective equipment operation. PROFILE OF A PROCESS APPLICATION - GRAVITY DRAINAGE, SHELL AND TUBE HEAT EXCHANGER Tubes, coils or jackets are used with heat exchangers, tanks or vats for heating liquids in either batch or continuous operation, typical of shell and tube heaters. Equipment is generally protected from the weather and typically features a single coil. Heavy startup loads, followed by smaller running loads are to be expected, but without the extreme swings of weather-exposed equipment. Adequate air venting is most important as the equipment is often run on daily or weekly schedules. Tendency is for total shutdown of equipment following completion of run or batch. Air in a heating system significantly reduces its efficiency. Air is a very poor conductor of heat and air filming on pipes and heat exchanger tubes reduces the heat transfer rate through their metal walls. Also, steam mixed with air contains fewer BTUs at a given pressure than steam alone. It is the function of a steam trap to aid in venting air from a steam system, but auxiliary thermostatic air vents are often required. Open to cooler air and closed to hotter steam they greatly speed up the air purging process. When frequent startups and shutdowns are the rule, rapid air purging is a significant factor. Yarway lever style thermodynamic traps are often favored for their excellent air handling characteristics on startup. PROFILE OF A PROCESS APPLICATION - SYPHON/LIFT DRAINAGE ROTARY DRIER (USING LEVER TRAPS) In this application, continuous drying of materials is being performed by exposure to the heated surfaces of rotating cylinders or drums. Commonly used in the manufacture of felt, rubber, textiles, paper and other sheet or fibrous materials, including foods and slurries of chemicals. Higher start-up loads and moderate running loads are typical. When several dryers are in series, the first will have the highest load while those toward the end have progressively smaller loads. Each dryer should be trapped individually to prevent flooding. Syphon drainage is standard practice. CAUTION! Condensate moving up the syphon from the outer rim to the center of the drum is subject to reheating and flashing. Flashed condensate can break the siphon (steam binding). Therefore, steam traps must have hot discharge and fast response with the ability to handle flash steam by means of a small bleed passage. Air venting capability is an important requirement during start-up when drums or cylinders contain large amounts of air. Shell and tube heater Steam line Auxiliary air vent A Rotating cylinder dryer (syphon drained) Steam Autoclave Trap 2

THE RIGHT TRAP FOR THE RIGHT APPLICATION Why choose a thermodynamic steam trap? Thermodynamic traps are phase detectors in that they can discriminate between condensate and steam. The working principle is simple and, with only one moving part, these devices are small and rugged. There are three basic types of thermodynamic traps which differ from one another by the configuration of the valve they use to open and close a port. Each is well-adapted to a particular set of service conditions. The main thermodynamic feature that is desirable in process applications is the hot-running design and responsiveness to load changes. Thermodynamic traps also handle air very well, which is essential to an efficient heat transfer rate. This requires an understanding that steam mixed with air contains fewer BTUs at a given pressure than pure steam. Variable orifice traps These traps are designed for a variety of high pressure applications found in utility, industrial and marine service. Typical applications include: fuel oil heaters, air heaters, reboilers, soot blower drains, steam separators, and shell and tube heat exchangers. The small lightweight design and broad range of operating pressures are among the many advantages when compared to mechanical traps of the same pressure rating. Yarway variable orifice traps offer the following advantages: Moderate capacity Excellent air handling Designed to fail open Designed for superheat In-line renewable Long life materials Broad range of pressure class Integral screen Compact and lightweight Factory set and assembled internals Optional blow-off valve connection End connections - socketwelding standard Seaworthy - shock and vibration tested Lever style traps These traps are especially suited for outdoor service and freezing environment, and where the equipment has siphon or lift drainage. The built-in control orifice prevents steam binding as well as promoting excellent air handling. Among the typical applications are air blast heating coils, batch stills, autoclaves, reboilers, rotating cylinder dryers, and shell and tube heaters. All Yarway lever valve traps deliver consistent features such as: High capacity - replaces traps of larger physical size Excellent air handling Fail-safe in the open position to help maintain production Lever valve is only moving part Stainless steel internals Unaffected by corrosive condensate, freezing, and water hammer In-line maintenance - factory matched repair kit installed in minutes Full range operation - without adjustment High temperature discharge How it works - lever style design On startup, air is handled through a control orifice. Only cool condensate or a mixture of condensate and air, will open the valve lever. As steam temperature condensate reaches the trap, flashing begins in the outlet orifice, building up pressure in the chamber above the lever. The lever closes as the chamber pressure increases. A small control flow permits quick response to inlet conditions. A slight drop in condensate temperature, for instance, reduces the chamber pressure, quickly opening the lever. Lever traps are designed for applications having large condensate loads and where rapid discharge of condensate is a requirement. Lever valve Strainer Inlet valve Control orifice Upper chamber Outlet orifice Chamber Valve Control orifice How it works - variable orifice design Variable orifice traps differentiate between the energy in cool condensate and flashing condensate as well as gases. Cool condensate opens the valve because the pressure in the chamber above the valve is low. The cool condensate readily drains through the control orifice from the chamber. Hot flashing condensate chokes the flow in the orifice and raises the chamber pressure. The increased chamber pressure closes the valve. When the valve is closed, a small amount of condensate continuously drains through the control orifice, making the trap responsive to changes in condensate load. 3

SERIES C-250 AND C-260 HIGH PRESSURE TRAPS (VARIABLE ORIFICE) The Yarway high pressure integral strainer trap is designed with Quick Change Trim (QCT) using the proven variable orifice (piston) internals. These traps are designed for a variety of high pressure applications found in utility, industrial and marine service. Typical applications include: fuel oil heaters, air heaters, reboilers, soot blower drains, steam separators, and shell and tube heat exchangers. The small lightweight design and broad range of operating pressures are among the many advantages when compared to mechanical traps of the same pressure rating. In addition, the QCT design is renewable in-line with factory set and assembled internals. Back pressure ratings Back pressure to 25% as factory set; (to 55% with removal of split washer, based on absolute pressure, C-250 only). Ordering 1. Designate size of end connections. 2. Designate figure number. 3. Designate trap internals (capacities curve and selector guide). 4. Designate R for commercial. Example: 1½ C-250ESWR. Applicable codes and standards Pressure ratings per ANSI/FCI-69-1. Performance testing per ANSI/ASME PTC-39.1, ISO 7841 and 7842, FCI 69.1 and 85.1. End connections per ANSI B16.11. How to interpret the curves For optimum service life limit the C-250 to 100 bar operation and the C-260 to 103 bar operation. Traps will operate above recommended pressure (C-250 up to 69 bar, C-260 up to 207 bar). However, the service life may be reduced. How to specify and order Typical specification the trap shall be Piston Valve, Quick Change Trim, Integral Strainer, Impulse Trap and shall require neither bucket, bellows nor bimetallic element for operation - (option ½ socketweld blow-off connection). CONDENSATE CAPACITY NEAR STEAM TEMPERATURE (FOR STEAM TRAP SIZING) PRESSURE/TEMPERATURE RATINGS Steam trap flow rate, lb/hr 15,000 10,000 4 250 3 2 8 7 6 5 4 3 2 Steam trap inlet pressure, bar 10 20 250/260 30 40 50 60 70 100 200 C-250 G internals 6000 5500 5000 4500 4000 3500 3000 2500 2000 1700 1400 1100 Consult press.-temp.curve 1,000 500 56789 100 2 3 4567891,000 2 3 45 260 Nominal pressure ranges Steam trap inlet pressure, psi C-250, C260 E Internals 300 800 Steam trap flow rate, kg/hr Max. pressure, psi 4000 3500 3000 2500 2000 1500 1000 500 All liquid phase Saturation curve 0 0 100 200 300 400 500 600 700 800 900 1000 1100 Max. temperature ( F) All super-heat Series C-250 Series C-260 4

SERIES C-250/C-260 14 4 9 15 1 6 5 7 8 18 11 2 12 D C B 10 13 E A 3 17 16 G H MATERIALS AND SPECIFICATIONS Item Part Material 1 Body Cast chrome moly ASTM A-217 Gr. WC6.15 Max C (body) 2 Trap bonnet Cast chrome moly ASTM A-217 Gr. WC6.15 Max C (body) 3 Strainer bonnet Cast chrome moly ASTM A-217 Gr. WC6.15 Max C (body) 4* Lock nut Stainless steel AISI Series 400 5* Control cylinder Stainless steel AISI Series 400 mod 6* Control cylinder adapter Stainless steel AISI Series 400 7* Seat Steel AISI Series 400 heat treated 8* Valve piece Stainless steel AISI Series 400 heat treated 9* Lock pin Brass (C-250) Monel (C-260) 10* Screen Stainless steel AISI Series 300 (0.020 perf.) 11* Bonnet gasket (trap) Inconel spiral wound non-asbestos 12* Seat gasket Inconel spiral wound non-asbestos 13 Bonnet gasket (strainer) Inconel spiral wound non-asbestos 14 Stud (trap bonnet) Steel ASTM A-193 B-16 15 Nut (trap bonnet) Steel ASTM A-194 Gr. 7 16 Stud (strainer bonnet) Steel ASTM A-193 B-16 17 Nut (strainer bonnet) Steel ASTM A-194 Gr. 7 18* Split washer Brass (C-250 only) * Supplied in a renewal kit DIMENSIONS/WEIGHTS Dimensions, in. (mm) Weight Series Size A B C D E G H lb. (kg) C-250 1 (25) 11½ (292) 5 (127) 5 (127) 7½ (190) 4⅛ (105) 1.335 (34) ½ (15) 39 (18) C-250 1½ (40) 11½ (292) 5 (127) 5 (127) 7½ (190) 4⅛ (105) 1.915 (48) ½ (15) 39 (18) C-260 1 (25) 14⅜ (365) 5½ (140) 5⅛ (130) 7½ (190) 5¼ (133) 1.335 (34) ½ (15) 62 (28) C-260 1½ (40) 14⅜ (365) 5½ (140) 5⅛ (130) 7½ (190) 5¼ (133) 1.915 (48) ½ (15) 62 (28) C-260 2 (50) 14⅜ (365) 5½ (140) 5⅛ (130) 7½ (190) 5¼ (133) 2.406 (61) ⅝ (16) 62 (28) 5

SERIES 40/40D LEVER VALVE TRAPS The Series 40/40D is designed for use in industrial process applications for pressures up to 100 bar and condensate loads to 36.300 kg/hr. Applicable codes and standards Pressure ratings per ANSI/FCI-69-1. Performance testing per ANSI/ASME PTC-39.1. End connections per ANSI B1.20.1. for threaded ends, per ANSI B16.11 for socketwelding ends, and per ANSI B16.5 for flanged ends. How to size Required steam trap flow rate = maximum expected condensate load (lb/hr) x Safety load factor. A safety load factor of 2-4 is usually recommended. Then select a trap from the condensate capacity chart. Do not size based on end connection. How to specify, order and install Typical specification The trap shall be thermodynamic lever valve type requiring neither bucket, float, bellows, nor bimetallic element, with stainless steel internals and chrome moly body and bonnet. Ordering Specify trap size and series. Threaded end connections are standard; socketwelding or flanged ends are available. Repair kits are supplied as sets of matched parts (lever valve, seat, gaskets). Order by size and series. Installation nstall trap bonnet up in a horizontal position. Pitch lines to and from trap for gravity drainage. CONDENSATE CAPACITY (FOR STEAM TRAP SIZING) Steam trap inlet pressure, bar Steam flow rate, lb/hr Steam flow rate, bar Steam trap inlet pressure, psi RATINGS (DESIGN - FCI CLASS 600) Pressure Max. temperature, Back pressure Series Size in (DN) range psi (bar) F ( C) 40D ½, ¾ 2-600 750 (15, 20) (0.14-42) (400) 40D 1 5-600 750 (25) (0.34-42) (400) 40 1-½, 2, 3 20-600 750 (40, 50, 80) (1.38-42) (400) NOTE Operates against back pressure at trap outlet up to 40% of pressure at trap inlet. Based on absolute pressure when trap is discharging. 6

SERIES 40D / SERIES 40 DIMENSIONS/WEIGHTS SERIES 40D Size* Dimensions, in. (mm) Weight (DN) A B C D E lb. (kg) ½ 3-⅛ 2 3 /16 1 9 /16 2 1 3 /16** 2 (15) (79) (56) (40) (51) (48) (0.91) ¾ 4 2 13 /16 2 1 /16 2⅝ 1½** 3¾ (20) (102) (71) (52) (67) (38) (1.71) 1 5 3 9 /16 2 11 /16 3½ 1¾** 8 (25) (127) (90) (68) (89) (44) (3.6) * NPT Standard. Socketwelding or flanged end connections also available. Consult Yarway. ** Hex. DIMENSIONS/WEIGHTS SERIES 40 Size* Dimensions, in. (mm) Weight (DN) A B C D E lb. (kg) 1-½ 7 4⅞ 3 9 /16 4⅜ Ø 2⅝ 14 (40) (178) (124) (90) (111) (67) (6.4) 2 7⅝ 5⅞ 4 5 /16 5⅛ Ø 3⅛ 22 (50) (194) (149) (110) (130) (79) (10.0) 3 10⅝ 8 3 /16 6 1 /16 7⅜ Ø 4⅝ 65 (80) (270) (213) (154) (187) (117) (29.5) * NPT Standard. Socketwelding or flanged end connections also available. Consult Yarway. MATERIALS AND SPECIFICATIONS SERIES 40D Item Part Material 1 Body Forged Cr-Moly steel ASTM A182 F22 2* Bonnet Forged Cr-Moly steel ASTM A182 F11 3* Lever valve Stainless steel Type 410, heat treated 4* Seat Stainless steel Type 410, heat treated 5* Inlet valve Stainless steel Type 410, heat treated 6* Bonnet gasket Monel 7* Body gasket Monel 8* Outlet port gasket (1 size only) Monel 9 Cap screw Alloy steel heat treated 10 Nameplate Stainless steel 11 Drive screw Stainless steel 12* Inlet valve rivet Stainless steel Type 410 13 Spring pin Stainless steel Type 303 * Denotes available repair kit MATERIALS AND SPECIFICATIONS SERIES 40D Item Part Material 1 Body Cast Cr-Moly steel ASTM A182-F22 (size 1½ and 2 ) A217-WC9 (size 3 ) 2 Bonnet Cast Cr-Moly steel ASTM A182-F11 (size 1½ and 2 ) A217-WC6 (size 3 ) 3* Lever valve Stainless steel Type 410 4* Seat Stainless steel Type 410, heat treated 5* Inlet valve Stainless steel Type 410, heat treated 6* Outlet valve Stainless steel Type 410, heat treated 7* Body gasket Stainless steel spiral wound (non-asbestos) 8* Bonnet gasket Stainless steel spiral wound (non-asbestos) 9* Outlet port gasket Stainless steel spiral wound (non-asbestos) 10 Outlet port bushing Stainless steel Type 304 11 Cap screw Alloy steel heat treated 12 Drive screw Stainless steel 13 Nameplate Stainless steel * Denotes available repair kit 7

8