Thermostatic Steam Traps

Similar documents
Hoffman Specialty General Catalog

TABLE OF CONTENTS STEAM TRAPS INVERTED BUCKET SERIES PAGE FLOAT AND THERMOSTATIC SERIES PAGE THERMOSTATIC THERMODISC B0 26. How to Select All 107

We are working toward the goal of repairing all F&T traps made by all manufacturers, as we have done with thermostatic traps.

Inverted Bucket Steam Traps. for efficient condensate drainage of industrial and HVAC equipment

Documento Descargado desde:

APT and APT14 Automatic Pump Traps. for effective condensate drainage and removal

NICHOLSON STEAM TRAP THERMODYNAMIC STEAM TRAPS

THERMODYNAMIC STEAM TRAPS

LIQUIDATOR UMT-TD Series Thermodynamic

Main Steam Vents. Hoffman Specialty Regulators. How to Select Steam Vents

Technical Data CONDENSATE COMMANDER PUMP SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 9902D

Air Vents for Hot and Chilled Water Systems

Spirax-Sarco Industrial Thermostatic Steam Traps

THERMODYNAMIC STEAM TRAPS

YARWAY NON-REPAIRABLE DRIP AND TRACER STEAM TRAPS SERIES PB, 29, 129Y AND 29S

THERMOSTATIC STEAM TRAPS

MODEL P. 2 ft. NPSH Cast Iron Bronze Fitted Low NPSH Centrifugal Pumps. BULLETIN 112 Revised 7/09. PH (Horizontal Flange Mounted)

LIQUIDATOR 450 SERIES

Catalog No. 108-C. Steam Traps

Comparison Chart Macon Controls Specifications Helpful Heating Hints E-Z Fit Conversion Kits Macon Controls - Warranty

Float & Thermostatic Steam Traps for efficient condensate drainage of industrial process and HVAC equipment

Economical and simplified solutions that offer quality and optimum steam trap service.

Steam Water Washdown Unit

VENTS. Main Steam Vents. How to Select Steam Vents. For Steam Vent selection information, please refer to Selection Guidelines on page 133.

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD

THE PRESSURIZED CONDENSATE RECOVERY SYSTEM:

The. Steam ONE-PIPE STEAM SYSTEMS

A M E M B E R O F T H E K E N D A L L G R O U P

HEATING & HYDRONICS ZOELLER PUMPS HOUSTON ORLANDO GREENVILLE 800/ / / TOTAL MAINTENANCE SOLUTIONS

INDOOR, SUSPENDED, STEAM OR HOT WATER HYDRONIC UNIT HEATER FOR VERTICAL OR HORIZONTAL CONFIGURATION

Condensate Boiler Feed Water Make-Up

MD-170 Installation/Operator's Manual

"SXDDR" Series Steam Heat Exchanger Humidifiers

What is a Secondary Pressure Drainer?

Pumps. Pressured-powered pump catalog. The more reliable and efficient way to pump condensate and other liquids.

VERTICAL STEAM AND HOT WATER UNIT HEATERS

Case 15 Refrigeration System for Chemical Fertilizer Plant Ammonia Storage

Electric Pumps. Introduction. W4100, W4200 & W4300 Condensate Pumps. Typical Condensate Pump Features

STEAM AND TRAP FUNDAMENTALS

FT600 & FT601* Steam Traps Float & Thermostatic Steam Trap. Float & Thermostatic STEAM TRAPS

SECTION STEAM AND STEAM CONDENSATE SPECIALTIES

Steam Trap Presentation for IDEA Distribution Workshop. Presenter: Joe Radle

Hoffman Specialty Pump Products

Wide range of steam traps that provide consistent performance in less than perfect conditions.

Silhouette. Feedwater Heater. Boiler Feedwater

STEAM TRAP HEALTH MONITORING SERVICE EXECUTIVE SUMMARY

UNIVERSAL STYLE STEAM TRAPS WU450 Series

Mini Pump Trap. Features: n Low maintenance - No leaking seals, impeller or motor problems reducing maintenance and downtime.

Yarway Repairable Drip and Tracer Steam Traps Series 751/761, 711/721, 731/741, 500/546, 460/515/D3

APPLICATION GUIDELINES STEAM MAIN DRAINAGE

STEAM TO STEAM HUMIDIFIER

Domestic Pump Condensate Transfer Equipment

YARWAY PROCESS THERMODYNAMIC STEAM TRAPS SERIES 40/40D AND C250/260

Spiratec R16C Automatic Steam Trap Monitor

Series 151 and AV5. A wide range of process thermostatic steam traps is available to match almost any application need.

FM 517 San Leon, TX Toll Free: Office: (281) Fax: (281)

Inverted Bucket Steam Traps

RA2000 Thermostatic Radiator Valves

WATER HEATERS / BOILERS GSB8-E. Gas-Fired Steam Boiler PRODUCT SPECIFICATIONS. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB E

A complete, compact steam heat exchange solution for process and domestic water heating requirements.

GSB8. CONSERVATOR Gas-Fired Steam Boiler. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB S MODEL NUMBER IDENTIFICATION FEATURES

5. CONDENSATE PUMPS/UNITS

Cascade Refrigeration System for LPG Subcooling. Related Technical Data and Information for the Case:

Liquid Drainers LIQUID DRAINERS

NHS Sustainable Development: 14 th February Reduce Energy Consumption Through Steam System Modernisation. National Key Account Manager

Case 8 Basic Performance of Screw Compressor

YARWAY PROCESS THERMOSTATIC STEAM TRAPS SERIES 151 AND AV5

General Purpose Ventilation Fan - Venturi-Style Blower PSIG

Pressure Steam Humidifiers LS SERIES. humidity.com

HEAT EXCHANGER FORMULAS & EXAMPLE

WELCOME TO THE AWT REGIONAL TRAINING PROGRAM

Armstrong J Series Float, Thermostatic Steam Traps, Condensate Controllers & Liquid Drainers Installation and Maintenance Manual

The. Steam TWO-PIPE STEAM & PUMPED RETURN

IMPROVING EFFICIENCY AND QUALITY USING A PERMANENT ORIFICE STEAM TRAPPING SYSTEM

A hydronic system controls comfort by delivering heated or cooled fluid to the conditioned space through pipes.

Inverted Bucket Float & Thermostatic Radiator Traps STEAM CONTROL PRODUCTS STEAM TRAPS

Armstrong Steam System Solutions for the Hydrocarbon and Chemical Processing Industries

Armstrong Steam System Solutions for the Hydrocarbon and Chemical Processing Industries

Pressure Steam Humidifiers. Designed to deliver reliable humidity from facility steam boilers. Live Steam

heating liquids PENBERTHY JET PUMP TECHNICAL DATA Section 1000 Bulletin 1400 Issued 6/87 Replaces 6/85

Published by. $19.95 per copy. Copyright 2017 by Spirax Sarco, Inc.

AIR CONDITIONING. Carrier Corporation 2002 Cat. No

How to Trap: Steam Tracer Lines

SECTION SECTION DESIGN REQUIREMENTS

HEATING & HYDRONICS TOTAL MAINTENANCE SOLUTIONS

MODEL M5M. High-Efficiency Packaged Watertube Boiler MMBTU

MECHANICAL STEAM TRAPS

Residential & Commercial

/ / Take the technological step into MODERN Condensate Handling Equipment for steam systems MANUFACTURED IN AMERICA with craftsmanship and quality.

Series 1156F, 1450F ( 1 2") Feed Water Pressure Regulators and Dual Controls for Hot Water Boilers

THE PIVOTROL PUMP (Patented) Featuring Reliable PowerPivot Technology

WAL-RICH CORPORATION SINCE 1950

Insty-Pac Steam Humidifiers

AD-410 Models AD-410 NON-TILT* 1 DOOR GAS MODEL AD-410 NON-TILT* 1 DOOR STEAM MODEL

Date: Project #: Engineer: Prepared By: Bid Date:

Industry Best 10 Year Commercial Warranty

THE THERMOSTATIC STEAM TRAP

Product Family Overview

AD-236 AD-330. AD-360x2 AD-4545

SECTION. Hot Water ARMSTRONG PRODUCT CATALOGUE

Transcription:

Hoffman Specialty Thermostatic Series 7 alanced Pressure The Series 7 alanced Pressure Thermostatic Steam Traps are for institutional, commercial and residential heating system applications such as schools, hospitals, apartment buildings, homes or others where low or moderate water hammer may occur. elimination of flash steam losses on low pressure systems NPT and SPT ngle, Vertical NPT Swivel NPT and SPT ngle, Vertical " NPT and SPT ngle Replaceable Dura-Stat module -Year Warranty Meets Mil specification --6000 Type V, Style, lass and 2 Maximum operating pressure 25 psig (.7 bar) Model 7 ngle (with short nipple) Model 7 ngle Model 7 ngle Model 7 ngle " Model 7 Vertical Model 7 Swivel Model 7 Straightaway 20

Hoffman Specialty Series 7 alanced Pressure Size Model Pattern in. 7-S-2-25 ngle (w/short Nipple) 2 2 27 2 (72) 4 (2) 7--2-25 ngle 2 4 (8) 4 (2) 7-V-2-25 Vertical 2 4 2 2 (20) 2 8 (54) 7-SV-2-25 Swivel 2 4 (8) 5 6 (24) 6 (46) 7---25 ngle 4 8 (79) 2 (8) 7-S--25 Straightaway 4 5 2 (80) 8 (29) 5 8 (4) 7--4-25 ngle 7 2 (82) 4 (45) cross Trap psi (bar) 4 2 2 2 5 0 5 25 (.07) (.04) (.069) (.0) (.4) (.5) (.7) (.0) (.7) Series apacity lb/hr (kg/hr) 7 42 5 6 72 77 02 25 40 62 (9) (2) (29) () (5) (46) (57) (64) (7) Series 7 capacities are based on 40 F (22 ) subcooling. old capacity is approximately 4 times capacity shown. SHEM Series cross Trap psi 4 2 2 2 5 0 5 25 apacity sq. ft. EDR* 7 85 20 65 200 25 70 50 640 800 * Ratings are in accordance with recommended standards established by the Steam Heating Equipment Manufacturers association (SHEM). sq. ft. EDR is equivalent to a heat emission of 240 TU per hour with 2 psig steam filling a radiator surrounded by 70 F ambient air. To convert sq. ft. EDR to lbs. of condensate, or steam per hour, divide the sq. ft. rating by 4. NPT SPT NPT SPT Pressure Model Model Size Part Part Rating Weight Number Number in. Number Number psi (bar) lbs. (kg) 7-S-2-25 ngle (w/short nipple) 2 40542 25 (.7).2 (.54) 7-2-25 ngle 2 4056 25 (.7).2 (.54) 7-V 2-25 Vertical 2 4055 25 (.7).2 (.54) 7-SV-2-25 Swivel 2 40545 25 (.7).2 (.54) 7---25 ngle 7--J-25 ngle 4 402006 40204 25 (.7).5 (.7) 7-S--25 Straightaway 4 4020 25 (.7). (.6) 7--4-25 ngle 40202 25 (.7) 2. () 2

Hoffman Specialty Thermostatic (continued) Series 8 alanced Pressure The Series 8 alanced Pressure Thermostatic Steam Traps are for institutional and commercial heating system applications or others that require high capacity operation. NPT and SPT ngle NPT and SPT ngle or Straightaway elimination of flash steam losses on low pressure systems Model 8 ngle Replaceable Dura-Stat module -Year Warranty Meets Mil specification --6000 Type V, Style, lass - 4 Maximum operating pressure 25 psig (8.6 bar) Model 8 ngle Model Pattern Size 8 ngle 2 2 27 2 (72) 4 (2) 8 ngle 4 8 (79) 2 (8) 8 Straightaway 4 5 2 (80) 8 (29) 5 8 (4) Model 8 Straightaway NPT SPT NPT SPT Pressure Model Model Size Part Part Rating Weight Number Number in. Number Number psi (bar) lbs. (kg) 8--2-25 ngle 8--2J-25 ngle 8---25 ngle 8--J-25 ngle 8-S--25 Straightaway 2 402002 402008 25 (8.6).5 (.7) 4 40200 402009 25 (8.6).5 (.7) 4 402004 25 (8.6).5 (.6) cross Trap psi (bar) Series 4 2 2 2 5 0 5 25 50 00 25 (.07) (.04) (.069) (.0) (.4) (.5) (.7) (.0) (.7) (.5) (6.9) (8.6) apacity lbs./hr (kg/hr) 8 0 50 20 255 00 480 760 950 50 200 500 4200 (50) (68) (95) (6) (6) (28) (45) (4) (62) (95) (590) (905) Series 8 capacities are based on 0 F (7 ) subcooling. old capacity is approximately 2 times capacity shown. 22

Hoffman Specialty Thermostatic (continued) Series 9 alanced Pressure The Series 9 are for institutional and commercial heating system applications or others that require high capacity operation. elimination of flash steam losses on low pressure systems. " NPT ngle Replaceable Dura-Stat module -Year Warranty Meets Mil specification --6000 Type V, Style, lass - 4 Maximum operating pressure 25 psig (8.6 bar) Model 9 ngle " NPT Model Pattern Size 9 ngle 7 2 (82) 4 (45) NPT NPT Pressure Model Size Part Rating Weight Number in. Number psi (bar) lbs. (kg) 9--4-25 ngle 402005 25 (8.6) 2. () cross Trap psi (bar) Series 4 2 2 2 5 0 5 25 50 00 25 (.07) (.04) (.069) (.0) (.4) (.5) (.7) (.0) (.7) (.5) (6.9) (8.6) apacity lbs./hr (kg/hr) 9 0 50 20 255 00 480 760 950 50 200 500 4200 (50) (68) (95) (6) (6) (28) (45) (4) (62) (95) (590) (905) 2

Hoffman Specialty Thermostatic (continued) ompetitive brand changeover to Hoffman Specialty Model 7 Hoffman Dimensions in. (mm) Specialty Model ear Trap Manufacturer Number Part Number arnes & Jones 22 (76) 4 (2) 4056 Dunham ush /Mepco E-P 8 (79) 8 (29) 4056 Erwell R0 4 (8) 2 (8) 4056 Illinois G, GS 2 7 8 (7) 8 (29) 40542 MG Spirax Sarco TS-25 2 6 (7) 6 (0) 40542 Sterling 7-50 4 (8) 4 (2) 4056 Trane 4 (8) 6 (27) 4056 Warren Webster 502, 702 2 4 (70) 8 (29) 40542 Hoffman Specialty 7 4 (8) 4 (2) 4056 w/std. nipple Hoffman Specialty 7 2 27 2 (72) 4 (2) 40542 w/short nipple Dura-stat Replacement Modules For arnes & Jones, Dunham-ush, Illinois, Spirax-Sarco, and Hoffman Specialty Thermostatic. The all Stainless Steel Dura-stat Replacement Module should be used to upgrade thermostatic steam traps. The Dura-stat is durable and water hammer resistant. Selection NPT Size Dura-stat Trap Manufacturer in. Model Number Part Number: Hoffman Specialty 2 7 600084 Spirax-Sarco 2 T-25, TH-25, TS-25, H 600056 arnes & Jones 2 22 60005 Dunham-ush/Mepco 2, E 600052 Illinois 2 G 600056 Warren Webster 2 02H, 502 600250 24