Deep integrated renovation the Estonian KredEx renovation grant programme experience. Jarek Kurnitski September 14, 2017 Rakvere

Similar documents
Performance of Heat Recovery Ventilation System with Ground Source Brine Heat Exchanger Pre- Heating System in the Context of nzeb

nzeb office building

Residential Heat Recovery Ventilation. REHVA European Guidebook No 25

Passivhaus. sally godber MEng CEng MIMechE WARM: Low Energy Building Practice. The first 3 in the UK.

Modular prefab integrated HVAC units: description and development of demonstration units (D2.3)

Energy Efficiency Standards

The Corbioli House is a single-family house situated

MICROCLIMATE SYSTEMS CHARACTERISTICS OF A THREE FLOOR HOTEL IN VILNIUS

Simplified Space-Heating Distribution using Radiators in Super-Insulated Apartment Buildings

Home Energy Assessment Rebate Guide

AERECO DEMAND CONTROLLED VENTILATION COMBINING INDOOR AIR QUALITY AND ENERGY SAVINGS

Energy Upgrade California Home Upgrade Offered by The Energy Network

Retrofitting a Multi-Unit Residential Building To Reduce Purchased Energy by a Factor of 10. Chris Richards

Energy consumption in properties

Gas-Fired Condensing Boilers A Green Start To Space & Water Heating

Related party disclosure: Technical Information Benchmark. 99 m² 336 kwh/m² per year 73 kg/m² per year

Indoor Environmental Quality

WORKSHOP VENTILATION- PSYCHROMETRICS-AHU

Building services installation. Sustainable retrofitting of buildings- Sub module 3

MultiFamily Ventilation Updates: ASHRAE 62.2, Best Practices and Practical Applications RESNET Conference Atlanta, GA

Technical Report Three

Mechanical Ventilation with Heat Recovery: Designing and implementing a robust and effective ventilation system

SL-1 Passive Solar, Ventilation & Shading Design

Appendix C House models for Dymola to be used in connection with the OPSYS test rig and annual simulations of the performance of heat pumps

QUALITY CONTROL Passive House Checklist

Net Zero Design for Commercial Buildings

about your house Before You Start an Energy-Efficient Retrofit Mechanical Systems

BALTIMORE GAS AND ELECTRIC COMPANY (BGE) Home Performance with ENERGY STAR Program. Rebate and Incentive Instructions

Energy Efficiency Rating

DX SYSTEM HEAT RECOVERY ENHANCED BY DEMAND CONTROLLED VENTILATION

Forum for European Electrical Domestic Safety FEEDS. Residential Electrical Safety How to ensure progress?

Solar Sustainable Heating, Cooling and Ventilation of a Net Zero Energy House

Installation and Maintenance

SMART ERV Energy Recovery Ventilator. Build It Tight / Ventilate It Right!

Pre-seen case study for Strategic level examinations Papers E3, P3 and F3. For examinations in May 2014 and September 2014

VENTILATIVE COOLING CONTROL STRATEGIES APPLIED TO PASSIVE HOUSE IN ORDER TO AVOID INDOOR OVERHEATING

Installation and Maintenance

Energy efficient swimming pools 1.1 A SMART, EFFICIENT CLIMATE SHELL REFURBISHMENT SOLUTION

BlueHealth Environmental Assessment Tool (BEAT):

Florida Department of Transportation

Massachusetts COOL SMART

Building Codes, Ventilation Rates, and Certified Performance. Ventilation Track Comfortech 2007 St Louis, MO September 27, 2007

Mary Riley Custom Build Funding Limited Financing Methods Self Build / Custom Build / Community Group Self Build

The importance of hot water system design in the Passivhaus

Performance of the Low-energy House in Sisimiut

Des Places Residence Hall

Energy Efficiency Rating

Gas-Fired Condensing Boilers A Green Start to Space & Water Heating

VentZone Systems VentZone Zoned IAQ with Heat Recovery Kits

INVESTMENT PROJECT. Implementation by: JV UKRINTERM COMPANY LIMITED

Energy Efficiency Rating

The V in HVAC: Mechanical Ventilation in ENERGY STAR Certified Homes

Larch house and Lime house review of systems design and implementation

SolarPower Europe O&M Task Force

MECHANICAL VENTILATION

Residential ventilation concepts based on the idea of displacement airflow distribution

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) 2016 Q1

Julie Klump, POAH Rick Fenuccio, Tom Hartman Marc Rosenbaum Melpet preliminary heat loss and energy model results and implications

Uniform Dwelling Code 2017 Updates SPS 323

Renovation concepts for saving 75% on total domestic energy consumption

Vertical greening systems: social and private benefits and costs

Summary of 60-Day Notice: Heating Efficiency

Energy Performance Certificate

Ventilation. Product Information

Building Regulations 2010: What it means to you.

Installation and Maintenance

Intake air from outside. Supply air to house. Extract air. from house. Extract air from house. Exhaust air from house to outside

Heating Efficiency Program COLORADO

HOTLINE:

Ventilation in Humid Climates: Data from Field Experiments

Put the V back in HVAC

The Ed Roberts Campus

Clearing the Air: Ventilation. RESNET Building Performance Conference San Diego, CA February 17 th, 2015

A NEW ALDI FOOD STORE FOR KINGSWINFORD

REBATE. Ductless Mini-Split Heat Pump

A 92 plus B C D E F 21-38

Energy Performance Certificate

2019 Smart Energy Existing Homes Program Manual

Mechanical System Redesign. Dedicated Outdoor Air System. Design Criteria

Heat Pumps and Public Swimming Pools, a Perfect Match

HEAT RECOVERY VENTILATION For healthy, energy efficient ventilation

Villa Bagatelle Technical Report

Breathe Fresh Air at Home

Greenstar The World's Best Selling Condensing Boiler System

RÉSEAU EXPRESS MÉTROPOLITAIN

INTRODUCTION OF HYBRID VENTILATION SYSTEMS OF DWELLING BUILDINGS IN LATVIA

Your Energy Management Partner

Kills bills. How Vaillant technologies reduce home heating bills

Code of Practice - Ventilation- Mechanical Extract Ventilation (MEV) + Mechanical Ventilation with Heat Recovery (MHVR)

VentZone Systems VentZone Zoned IAQ with Energy Recovery Kits

GIZ NESP intervention on promoting the use of Solar Water Heaters in Educational Buildings and Hotels

Air Conditioning Refrigeration Electrical Work TEL: 0(204) (254)

Versa- Hydro. up to 96% Efficient

Cork County Energy Agency

SBEC Residential Energy Efficiency Rebate Programs for New Homes

Overview of Paldiski Windpark land-use planning and environmental impact assessment process

Solar Air Heating Roofing and Siding for Government and Commercial Buildings

HVAC/R Repair and Maintenance In The Current Economy. How To Minimize Costs

Energy Recovery Ventilation

The solar low-energy rehabilitation includes 21 apartments. The following energy saving measures are included here:

Transcription:

Deep integrated renovation the Estonian KredEx renovation grant programme experience Jarek Kurnitski September 14, 2017 Rakvere

SMART AND CLEAN ENERGY FOR ALL State of play: Energy Efficiency 2 #EnergyUnion

Energy use in Estonia Final energy use in Estonia 33 TWh/a The share of buildings 50% (without industrial buildings) EU average about 40% J. Kurnitski et al. / Energy and Buildings 75 (2014) 51 59 3

Lõpptarbimine hoonetes, GWh/a Hoonete energiakasutus Eestis Energia lõpptarbimine Eestis ca 33 32 TWh/a (2010 2015) Hoonete osakaal kasvamas üle 50% (ilma tööstushooneteta) EL keskmine 40% Normaalaastale taandatud lõpptarbimine hoonetes: 12,000 11,264 11,705 11,107 11,579 10,889 11,403 10,000 8,000 6,000 4,633 4,537 4,584 4,730 5,044 5,596 4,000 2,000 0 2010 2011 2012 2013 2014 2015 Kodumajapidamised Äri- ja avalik sektor 4

Apartment building stock (x 10 6 ) ~65% population living in apartment buildings ~95% of apartments are in private ownership not insulated, not ventilated Net area of apartment buildings, m 2 3,5 3,0 2,5 2,0 1,5 1,0 0,5 0,0 Construction year Wood Large-block Brick Large-panel

Apartment building stock Space heating, kwh/(m 2 a) DHW, kwh/(m 2 a) Electricity, kwh/(m 2 a) Primary Energy, kwh/(m 2 a) Energy Certificate Class 211 150 136 36 27 37 58 35 32 311 263 224 G F F

Grants 15%, 25% and 40% 2015- nzeb 40% 25% 15% Current state 2020 + more strict ventilation and other requirements 2010-2014 35% 25% 15%

Main steps in the KredEx grant application process Housing association decision simple majority 50% +1 in general assembly meeting Qualified technical consultant steering the preparation Energy audit/epc of the building and investigations (stacks etc.) Detailed technical design: full set of building design documents (including calculated EPC for compliance approval) Building permit applied/issued Credit decision from bank issued Grant application to KredEx: Investigation of design documents by third party experts (KredEx) Revision of design documentation if needed (applicant) Funding decision by KredEx if all requirements met Tendering with contractors Construction (KredEx has special supervision rights) Commissioning protocols for ventilation rates and heating system Grant payment by KredEx after handing over EPC based on measured use after one year operation

Results 2010-2014 (old system) Grants - 38 million euros Total investments 135 million euros 35% grant most popular (>50% in last years) Renovated apartment buildings 663 (of total of about 20 000 apartment buildings) Renovated net area 1,9 million m 2 Average energy savings per building 43% Total annual energy savings 60 GWh

Example: Sõpruse pst 202, Tallinn 11 375 m² (162 ap. 2012-2013) Investment 2 062 000, 181 /m² Grant 35% 721 600, 63 /m² Credit 1 340 000, 20 years Measured annual savings 63%, ~500 MWh

Example: Sõpruse pst 202, Tallinn External insulation of facade + roof insulation Triple windows (+moved to the insulation layer) Heating system: exhaust air heat pump + district heating Ventilation system: ventilation radiators and old stacks for extract

Ventilation problems 2010-2014 No specific ventilation requirements were set however EN15251 indoor climate category II was required Very low ventilation rates except in centralized mechanical supply and extract ventilation systems (Central AHU): Exhaust airflow from apartment, l/s 45 40 35 30 25 20 15 10 5 Natural ventilation average 5,6 l/s EN 15251 class II Room based AHU average 6,7 l/s Mechanical exhaust ventilation average 10 l/s Central AHU 34 l/s 0 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 Apartments Natural ventilation Room based AHU Mechanical exhaust ventilation with heat pump Central AHU Hamburg, A; Mikola, A; Kõiv T-A. Analysis of renovated apartment buildings indoor climate and energy consumption and their compliance with the standards and energy audits. 12

2015-2020 KredEx grants No need for state-loan (private banks have resources, well capitalized, low interest rates) 102 M, grants 15, 25 and 40% (50% for design, technical consultants, supervision) More emphasis on preparation, ventilation, energy monitoring: More detailed building design documents (full energy calculation in addition to energy audit + because of third party verification) Investigation of building design documents by third party experts (run by KredEx having contracts with qualified experts) Technical consultants Commissioning protocols for ventilation airflow rates and heating system balancing Agreements for post-maintenance Measured EPC after one full year of operation Guarantees are still inforce

KredEx renovation grant reqs 15% financial support EPC class E 25% financial support EPC class D (EP 180 kwh/(m 2 y)) 40% financial support EPC class C (EP 150 kwh/(m 2 y)) + some additional technical requirements especially for ventilation and insulation EPC class C the same value for new and renovated (in some countries could be called as renovation nzeb) 40% grant will keep the monthly payment for the occupant roughly at the same level before and after the renovation renovated building, improved indoor climate and real estate value being a bonus 25% grant slightly less cost effective because of tight ventilation requirements

Breakdown of 40% renovation grant EPC class C requirement (150 kwh/m 2 y) Apartment building with gas heating (for district heat slightly more heating is accepted because of primary energy factor of 0.9) Applies both for renovation with 40% grant as well as for new building Energy need, kwh/m 2 Delivered energy, kwh/m 2 Primary en. factor, - Primary energy, kwh/m 2 Space heating 22 25.7 1.0 25.7 Vent. heating 14 14.7 1.0 14.7 DHW 30 31.6 1.0 31.6 HVAC aux. 9.5 9.5 2.0 19.0 Lighting 7 7 2.0 14.0 Appliances 22.5 22.5 2.0 45.0 Total 105 111 150 Energy needs of DHW, lighting and appliances are regulated values Delivered energy of DHW depends on the system (efficiencies etc., in this case no solar collectors or heat pumps are considered)

KredEx ventilation requirements 25% renovation grant: Continuous an average ventilation (for total apartment) 0.5 1/h; Supply or intake air flow rates to be at least 10 l/s in bedrooms and living rooms at sound power level no more than 25 db(a); Extract air flow rates at least 10 l/s WC, 15 l/s bathroom and 8 l/s kitchen (10 l/s in bathroom and 6 l/s in kitchen in one room flats ); Preheating of intake air generally required (ventilation radiators recommended, but intake air vents accepted); Heat recovery is NOT required (but depending on the building, EPC class D might be difficult to achieve without HR) (for the heating system, balancing and installation of thermostats is required)

KredEx ventilation requirements Additional requirements for 40% renovation grant: (The same airflow rates as in the case of 25% grant) Mechanical supply and exhaust ventilation with heat recovery OR exhaust air heat pump with ventilation radiators required It is considered that ventilation radiators with filters and heating of intake air will provide similar good indoor climate as heat recovery ventilation EPC class C requirement is easier with heat recovery ventilation, exhaust air heat pump might need additional measures depending in the building

Sizing of ventilation in typical apartments Ventilation air flow rates according to requirements: Floor Exctract airflow rate, l/s Supply airflow rate, l/s Air change area, m 2 WC Bathr. Kitchen Total Living Bed1 Bed2 Bed3 Total l/s m 2 1/h Single room 35 10 6 16 10 10 0.46 0.63 1 bedroom 55 15 8 23 10 10 20 0.42 0.58 2 bedrooms 70 10 15 8 33 10 10 10 30 0.47 0.65 3 bedrooms 80 10 15 8 33 10 10 10 10 40 0.50 0.69 To balance the ventilation, supply airflow rates are to increased in small apartments and extract airflow rates in large apartments: Floor Exctract airflow rate, l/s Supply airflow rate, l/s Air change area, m 2 WC Bathr. Kitchen Total Living Bed1 Bed2 Bed3 Total l/s m 2 1/h Single room 35 10 6 16 16 16 0.46 0.63 1 bedroom 55 15 8 23 11 12 23 0.42 0.58 2 bedrooms 70 10 15 8 33 10 12 11 33 0.47 0.65 3 bedrooms 80 12 16 12 40 10 10 10 10 40 0.50 0.69

KredEx Insulation requirements U-value and thermal bridge requirements 25% grant 40% grant External wall (opaque), W/(m 2 K) 0.25 0.22 Windows (tot value), W/(m 2 K) 1.1 1.1 Roof, W/(m 2 K) 0.15 0.12 Linear thermal bridge (windowwall) W/mK - 0.05 In the case of 40% grant, windows are to be replaced and moved to the insulation layer in order to comply with thermal bridge requirement

Some examples of ventilation solutions: Natural ventilation Loomulik ventilatsioon: Ebapiisav õhuvahetus (peale akende vahetust) Puudulik siseõhu kvaliteet Kontrollimatu toimivus Suur energiakulu Puhub peale (värske õhu klappidega) Liigniiskus

Room ventilation HR units Additional exhaust ventilation needed from toilets, bathrooms and kitchens destroying the heat recovery room ventilation principle is not suitable for residential ventilation Most of equipment too noisy especially in bedrooms If small fans, may operate as intake vents because of stack effect no heat recovery at all Defrost protection often not working in a cold climate

Mechanical exhaust, exhaust air heat pump and ventilation radiator Heat recovery of: 60-70% (to domestic hot water and return of heating) Intake air: ventilation radiators in living rooms and bedrooms Extract air: kitchen, WC, bathroom Heat pumps: rooftops or in the basement Extract ductwork: tightened stacks or new

Mechanical exhaust, exhaust air heat pump and ventilation radiator Achievement of EPC class C may need some additional measures (better insulation, PV or heat recovery from waste water) Utilization of existing stacks need to be cleaned and tightened airflow rate measurements protocols are required

Mechanical supply and extract heat recovery ventilation rooftop and facade installation no ductwork in apartments

Experience with new system Most of the applications for 40% grant, first year was slow start, but then more applications than planned Key figures for 40% grant projects: Average financial support 93 /m 2 Average renovation cost (grant included) 246 /m 2 Average renovation cost 402 000 Centralized mechanical supply and extract HRV with rooftop AHU and facade ductwork installation one of the most popular ventilation solutions

2015 innovation economic facade installation of HRV ventilation

271 232 231 291 233 272 222 213 273 211 251 212 223 282 283 252 292 293 281 253 262 261 242 241 221 263 2103 2122 2102 2121 2123 2112 2111 2101 122 111 121 123 112 131 113 132 Ventilation 2015-2017 Measurement protocols report required ventilation rates in all apartments 263-1 223-3 222-1 222-2 222-3 251-2 251-3 251-4 212-3 253-1 253-2 252-2 261-2 253-3 271-3 271-2 213-2 273-3 251-1 211-1 232-1 233-3 291-2 273-1 252-1 231-3 233-4 291-1 293-1 293-4 231-1 273-2 261-1 242-1 261-3 242-2 231-2 263-2 212-2 272-1 272-2 292-1 292-2 292-3 293-3 223-1 281-1 283-1 282-1 232-2 211-2 213-1 293-2 233-1 233-2 271-1 282-2 262-2 241-1 212-1 283-2 242-3 241-2 262-1 223-2 221-1 281-2 213-3 221-2 Sissepuhkeõhu vooluhulk toas, l/s Measured in operation, average of all apartments 0,57 h -1 According to ventilation system: Heat recovery mechanical supply and extract 0,73 h -1 Exhaust air heat pump 0,32 h -1 Mechanical exhaust 0,32 h -1 Supply and extract air flows in the rooms in adequate level: Bedrooms and living rooms 9 L/s Bathrooms and toilets 11 L/s Average per person 6 L/s, pers First time in the history renovated apartments have adequate ventilation Õhuvahetuse kordarv, h -1 1,2 1,1 1,0 0,9 0,8 0,7 0,6 0,5 0,4 0,3 0,2 0,1 0,0 25 20 15 10 5 0 Soojustagastusega SP/VT n SP/VT = 0,73 h -1 Korteri kood Soojustagastusega VTSP n SP/VT = 0,32 h -1 Nõutud õhuvahetuse kordarv - 0,5 h -1 Elu- ja magamistoa nõutud õhuvooluhulk 10 l/s Korteri kood Korteri õhuvahetuse kordarv Soojustagastuseta VT n SP/VT = 0,32 h -1

Wider scope or renovation grants Estonian studies report highly significant economic benefits from renovation: quantified tax return of 32% of renovation total cost job creation of 18 jobs in a year per 1 M renovation cost E. Pikas, J. Kurnitski, R. Liias, M. Thalfeldt. Quantification of economic benefits of renovation of apartment buildings as a basis for cost optimal 2030 energy efficiency strategies. Energy and Buildings 86 (2015) 151 160.

Cost structure of renovation projects 12% 34% 54% Material costs, Labor costs for employer, Project management costs, Labor cost of 34% includes all labor cost in design, constructin and manufacturing Project management cost of 12% includes all costs in design and construction

Tax return breakdown 32% direct return VAT return 16,7% Labor tax return 15,6% From consultancy 0,4% From construction 16,3% From consultancy 0,5% From construction 11,9% From manufacturing 3,1%

2030 energy scenarios what can be done with building stock? (Energy action plan ENMAK 2030+) Scenario S1 Scenario S2 Integrated renovation variants Min Cost optimal Renovation rate of apartment buildings, %/a Renovation rate of detached houses, %/a Renovation rate of nonresidential buildings, %/a Building stock loss (demolition), %/a New construction rate in residential buildings, %/a New construction rate in nonresidential buildings, %/a Application of nzeb requirements in new buildings, a Scenario S3 Cost optimal 0.75 1.5 2.5 0.5 1.0 2.0 0.5 0.75 1.0 0.3 0.3 0.3 1.0 1.0 1.0 1.5 1.5 1.5 2026 2021 2016 31

Results: Final energy use J. Kurnitski et al. / Energy and Buildings 75 (2014) 51 59 Decoupling from energy use increase is not easy because of continuously increasing building stock First scenario S1 did not provide energy saving 32

Kui palju maksab ja kes maksab? Riigi tulud on S1 ja S2 puhul suuremad kui riigi kulud S3 võib olla põhjendatav tööhõive, ekspordi ning majanduse stimuleerimisega Maksumus Riik, M /a Maksumus Erasektor, M /a Tulud Riik, M /a Tulud Erasektor, M /a Otsene tööhõive in-a/a S1 3.6 48.5 17.5-1.4 880 S2 40.5 130.5 57.5 61.0 2850 S3 126.2 227.7 111.8 140.4 5620 Maksumused ilma uusehituseta, mille mahtu stsenaariumid ei mõjuta Riigi tuludeks on arvestatud maksutulu rekonstrueerimisest ja sisekliima tagamisega saavutatav sääst Erasektori tulud: energiasääst ja kinnisvara väärtuse tõus 33

S3 panustav stsenaarium 330 M /a rekonstrueerimise ehitushanked Toob riigile tagasi maksutulu laekumise 32% ehitushanked ehitusmaterjalide ja toodete valmistamine projekteerimine ja järelvalve Loob 5600 töökohta aastas: 1M ehitushange loob 17 töökohta Mobiliseerib erasektori investeeringud 228 M /a Pikas et al. 2014 34

Integrated renovation: adequate ventilation and indoor climate IAQ associated DALYs = 4900 DALY = 186 M cost for Estonian goverment in every year don t save energy on the cost of indoor climate DALY/year*million disability adjusted lifeyear. Blue: outdoor sources, red: indoor sources. (IAIAQ, 2011) 35

Summary Lessons learnt 2010-2014 period poor ventilation sometimes resulting in moldy apartments the most significant problem 2015-2020 grant system requires HRV ventilation (and commissioning protocols for verification) and moving windows to insulation level in the case of 40% grant as major changes Both changes were first seen as fully impossible by stakeholders, but after 6 months experience economic solutions were found Model renovation solutions KredEx renovation manual is prepared designers can copy and customize the model solutions Win-win-win situation, occupants benefit from increased real estate value, government from tax return and economic growth, and environment from saved energy