IMPORTANT CONSIDERATIONS

Similar documents
INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 870 SERIES INDUSTRIAL CONTROL PANELS

Specification Sheet. Equipment Model: BVAC-1200 Vacuum Furnace. Type. Chamber. Maximum Temperature 1250 C. Hot Zone

Vacuum Oil Purifier (VOP) (5 Pages. June 2017)

BURNERS/ FLARES. VAREC BIOGAS 244W Series WASTE GAS BURNER & IGNITION SYSTEM

PRODUCT REVIEW Honeywell HC900 Hybrid Vacuum Furnace Control System

LQ AQ SQ. Air-cooled and water-cooled portable chillers

Vacuum furnaces for brazing

WATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2

DIVISION FINNED WATER-TUBE WATER HEATERS

1.0 Denton Thermal Evaporator

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

LQ AQ SQ. Air-cooled and water-cooled portable chillers

General. Applications and Accessories for Oil Diffusion Pumps. leybold. Application. Accessories LEYBOJET 630 DIP DIP DIP DIP 30000

DIVISION FINNED WATER-TUBE BOILERS

Installation Requirements for Models:

PORTER INSTRUMENT COMPANY, INC. 245 TOWNSHIP LINE RD. P.O. BOX 907 HATFIELD, PA USA [215] / FAX [215]

WATER-TUBE POOL HEATERS

When reliability is vital. Alemite Carbon Shield TM Systems deliver

thermal management features such as temperature setpoint control, temperature ramp rate control, and process heating.

Fast Cycle Water Vapor Cryopump

Desiccant Air Dryers. ABP Series. Blower Purge Desiccant Air Dryer 70-8,000 scfm

INSTALLATION AND SERVICE INSTRUCTIONS. Tuthill atlantic fluidics OSR-5, 10,15 & 20. Oil sealed liquid ring vacuum pump

SECTION DOMESTIC WATER PRESSURE BOOSTING SYSTEMS (VFD) PART 1 - GENERAL 1.1 SUMMARY

WATER-TUBE POOL HEATERS

DIVISION COMMERCIAL, GRID-TYPE, FINNED-TUBE, GAS DOMESTIC WATER HEATERS

IQ/OQ Protocol Installation Qualification/ Operation Qualification zz FreeZone Stoppering Tray Dryer & Bulk Tray Dryer Freeze Dry Systems

Premium Efficient OIL-FREE Compressors

Fast Cycle Water Vapor Cryopump

Leica EM ACE600 Carbon & Iridium Coating System

DIVISION FINNED WATER-TUBE WATER HEATERS

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS DU/DUH DUAL OUTPUT RANGE INFRARED TUBE HEATERS

PILOT-15 CENTRIFUGAL MOLECULAR DISTILLATION SYSTEM

Heat up ramp rate 100 degrees C per minute - empty chamber.

Bench Series Ovens Models 21 / 31 / 51 Operating Manual

Furnaces. High Temperature Box Furnaces Deluxe Muffle Furnaces Economy Muffle Furnaces... 38

GEN II Linear Planar Magnetron Sputtering Sources

Design and Construction Standards SECTION PLUMBING EQUIPMENT

Heat Les Desiccant Compressed Air Dryers. DSE Series DSS Series DHD Series

Packaged Heat Pumps. Owner s Guide to Operating and Maintaining Your Heat Pump

Tempco s process controllers provide integrated solutions to manage your thermal loop system.

Scientific vapor pumps

DLCLRA. INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 TABLE OF CONTENTS

VACUUM OVEN. Model: VPX9-2. Installation and Operation Manual

A. Operation and Maintenance Data: For pumps to include in emergency, operation, and maintenance manuals.

AccuJet Electrostatic systems

Improved Dryer Control

SECTION AIR COMPRESSORS AND ACCESSORIES

Descaling Improvements at Charter Steel Cleveland Ohio. Presented by Chris Speckman IRD Conference April 2018

FSS-Series Heavy-Duty Flat panel Emitter Electric Overhead Infrared Heaters

HR Heated HB Blower. Smart Solutions for Drying Compressed Air. Dual Tower Heat Reactivated Desiccant Air Dryer

Aquapurification.com. Ozone. Ozonation Process: SGA Series: Ozone/Oxygen Systems:

WD7664 / WD7663 Maxon Burner Ellis Whisper Dryer Installation & Start UP

Vacuum System Troubleshooting Author: Keith Webb, P.E. Application Engineering Manager

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

Operation Manual R205BV, R209BV

LABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS

Vacuum Pumping process for Large Camera Dewars supplied by PixelVision of Oregon

ON-LOAD CLEANING FOR HEAT EXCHANGER FOULING. Optimising heat transfer on petrochemical plants and oil refineries

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

FAIRBANKS NIJHUIS SOLIDS HANDLING PUMPS.

Temptek Auxiliary Equipment

WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS

Forked Pyrolytic Platforms

Fig. 1 - Unit PHD4 and WPH4

! The Caution Symbol (exclamation point) alerts you to a "CAUTION", a safety or

Roots TM Blowers, Compressors & Controls

Bench-Top Vacuum Oven with 28 segments programmable controller

WATLOW IND. WATROD Circulation Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 6/11/2008 Rev: 2.00

CARBON MONOXIDE CO SS SOLID STATE ELECTROCHEMICAL SENSORS

Competitor Series Dryers

Fig. 1 - Unit PGD4, PGS4, WPG4

Gast Hazardous Duty Regenair Blowers

WKS 2200 SERIES (USA only) --INSTALLATION INSTRUCTIONS--

Band Heaters W A T L O W. Special Mica Barrel and Nozzle

SPECIFICATIONS MODEL EHV X VACUUM OIL PURIFIER

HS Dryer. Smart Solutions for Drying Compressed Air. Single Tower Heat Reactivated Desiccant Air Dryer. Engineered Air Products

SPECIFICATIONS MODEL E859C MINI DEHYDRATOR

DIVISION FINNED WATER-TUBE BOILERS

XRD XRD-1500 High-Temperature Oven. Innovation in Material Science...

Owner s Information Manual

twin tower desiccant compressed air dryers flow capacity: 200-9,000 scfm (340-15,300 Nm3/hr)

SECTION PLUMBING EQUIPMENT

26 Mesh Belt Brazing Annealing Furnace. Continuous Mesh Belt Brazing Furnace

MODEL MPM-2 MPM-9 MPM-18 MPM-50 LIQUID COLOR PRE-MIXER

OPERATING INSTRUCTIONS

WD7664 / WD7663 Maxon Burner. Ellis Whisper Dryer Installation & Start UP

Dual Tower Heat Reactivated Desiccant Air Dryer

DEEP VACUUM: ITS PRINCIPLE AND APPLICATION

Installation Instructions

RECOMMENDED LOCATION STEP BY STEP INSTALLATION. MODEL S 200P, 800BP and 97 POWER HUMIDIFIERS

Owner s Information Manual

Installation Instructions Owner s Manual

Removing the moisture contents of coal using solar drying

AGILENT VS SERIES LEAK DETECTORS

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

Vacuum Systems & Thin Films (Jaeger 6, Campbell 10&12, Ruska 7) Deposition of thin films involves vacuum system Direct Deposition from Source

DIVISION FINNED WATER-TUBE BOILERS

VAC-U-DRY VACUUM DEHYDRATOR

Maintenance and Troubleshooting of Oil Diffusion Pumps

Transcription:

NUMBER 6 SER VACUUM FURNACE REFERENCE I E S IMPORTANT CONSIDERATIONS When Purchasing a Vacuum Furnace

Important Considerations When Purchasing A Vacuum Furnace There are many factors that should be considered when investing in a new vacuum furnace. Although price is obviously important, there are many detailed design and other technical considerations buyers should evaluate to ensure that they select the best equipment for their requirements. A) HOT ZONE EFFECTIVE WORK AREA AND WEIGHT CAPACITY 1) Effective Work Area The effective work area should be selected based on the maximum part or load size to be processed. Do not purchase a larger furnace than required as operating cost will escalate and result in an unacceptable situation for the economics of the investment. Also, remember that with a circular hot zone, wider or taller parts can be accommodated. 2) Hearth Weight Capacity Normally, weight capacity of a furnace is specified based on maximum projected load weights that can be processed for a given work size and at a specific operating temperature. It is important that maximum load weight at a particular elevated temperature be included to assure proper furnace hearth design.

B) TEMPERATURE CONSIDERATIONS 1) Maximum Temperature Most manufacturers rate their furnaces to operate up to 2400 F. Solar Manufacturing builds their furnaces with capability to operate up to 2650 F. This is important for clean up cycles which help insure long term operation of the hot zone. Also, should a specific higher temperature requirement be necessary for a given process, the added temperature capability is available. 2) Temperature Uniformity It is important to state complete operating uniformity across the furnace operating range as there could be applications for the lower ranges. Solar Manufacturing states the following for our furnaces: a) +/ 20 F, 300 600 F, Conforms to AMS 2750D, Class 4 b) +/ 15 F, 600 900 F, Conforms to AMS 2750D, Class 3 c) +/ 10 F, 900 2500 F, Conforms to AMS 2750D, Class 2 3) Hot Zone Temperature Uniformity This is obviously dictated by insulation design and required openings necessary for various hot zone components and gas flow patterns. Some hot zone designs have difficulty meeting uniformity due to unacceptable gaps or openings especially on rear, baffled gas exit ports. Also, due to the inconsistency of the heat losses from the front to the back of a hot zone, it is essential to have a minimum of three zones of heating for proper trimming and adjusting power input. C) HOT ZONE CONSTRUCTION 1) Insulation Package Based on power loss studies for various insulation combinations, Solar Manufacturing has determined that the most acceptable insulation package consists of 0.040 Flexshield facing backed by 4 layers of ½ graphite felt all housed in a 0.090 thick 304 stainless steel support structure. Some furnace manufacturers use carbon steel for their support structure which we have found, from many years of experience, will eventually lose its shape and become severely oxidized or rusted and cause moisture absorption within the furnace, especially during humid summer operation. Note: For certain applications, especially for long cycles at elevated temperatures, we will add a fifth layer of graphite felt to further minimized hot zone losses and reduce power consumption.

2) Heating Elements Solar Manufacturing uses curved graphite type, ISO 63, resistance balanced and matched both on the original and replacement elements. It is most important that the elements be properly resistance matched to minimize potential temperature uniformity problems. Some other designs use bar elements that have been roughly sawed from a solid graphite block resulting in non uniform thicknesses. These often include a sharp bend or angle which could cause a stress point due to thermal expansion and contraction. 3) Work Support Rails These normally consist of heavy duty graphite rails supported by Molybdenum vertical members. The rails are top slotted to allow for Molybdenum rod inserts to minimize possibility of load contact reactions. Also, adequate clearance is provided under and between the rails for loading truck operation. 4) Heating Element Insulators Solar Manufacturing uses a U.S. patented design with excellent and proven electrical isolating results. Insulators are protected from contaminating vapors. Some other furnace manufacturers use molybdenum covers to protect the insulators. Our experience tells us that at elevated temperatures, this design will cause molybdenum vaporization resulting in serious insulation, metallization and short circuit problems. 5) Heating Element Indicators Solar Manufacturing provides front panel mounted current and volt meters for each heating zone of the hot zone. This allows for simple and easy proportional trimming when required on the furnace. Some other furnace manufacturers do not provide these important indicators.

6) Ground Light Indicators Solar Manufacturing provides these indicators for simple service checking of elements and electrical hot zone insulators. D) VACUUM PERFORMANCE FOR VACUUM FURNACES The values and times stated below should be required and used for basis of establishing furnace performance: 1) Ultimate Vacuum For a diffusion pumped furnace ultimate vacuum will be in the 10 6 Torr range. For furnaces using mechanical pump/blower only combinations, ultimate vacuum will be 20 Microns Hg or better. 2) Operating Vacuum With a diffusion pump, operating vacuum will be 10 5 Torr range. Without a diffusion pump, operating vacuum will be in the 50 60 Micron Hg range. Other furnace manufacturers state higher operating ranges. 3) Pump down Time To High Vacuum Cross over approximately 10 minutes. 4) Pump down Time To 1 x 10 4 Torr approximately 15 Minutes. Some other furnace manufacturers do not specify pump down time. 5) Furnace Leak Rate less than 5 Microns per hour. It is most important that the leak rate on any furnace be specified and guaranteed for proper and clean operation.

E) VACUUM SYSTEM COMPONENTS 1) Mechanical Pump Although there are several available manufacturers, Solar Manufacturing highly recommends Stokes Mechanical Pumps. This is primarily because they are designed in the U.S. and provide a much larger oil reservoir on the pump. The larger reservoir greatly improves operation during hot and humid days where water vapor is of great concern and must be removed via the mechanical pump. Other brands of pumps will not perform as well under these conditions. 2) Vacuum Blower Pump Again, we recommend Stokes for their U.S. design and proven reliability. 3) Diffusion Pump We prefer to use diffusion pumps made in the U.S. and recommend Varian as the manufacturer. They have been in the industry for many years and are highly respected for their equipment and performance. 4) Main Vacuum Valve poppet, right angle type. 5) Vacuum Roughing Port Solar furnaces provide direct pumping to the chamber. Although this means an extra port on the furnace chamber, it provides direct pumping access without going through the diffusion pump high vacuum valve.

F) FURNACE CHAMBER DESIGN 1) Basic Construction The chamber is manufactured using A36 Grade Steel and built to conform to ASME Code Section 8. It includes a standard double wall design allowing for proper water circulation throughout the main structure and heads. 2) Chamber Door Design Solar Manufacturing uses an autoclave type design with a rotating ring and standard Buna N type O rings. Protective shields are provided on the autoclave movement for personnel safety concerns. The door is operated manually and allows the operator to see what is happening as the door is closed. Other designs incorporate a powered door which can be useful but could be a personnel safety concern. They also use a rotating door seal which could be subject to dirt collection and seal failure. This design also makes it very difficult to replace the seal.

G) GAS COOLING SYSTEM 1) Internal/External Solar Manufacturing builds both types of cooling systems. There are plusses and minuses with each design. The external cooling system provides for easier access to the heat exchanger and drive motor but does use additional floor space. Our internal gas cooling systems are all housed within the vacuum confines and eliminate the need for any drive motor shaft rotating seals. Rotating seals are subject to leaks, early failure and are very difficult to replace. We also use a standard model drive motor. 2) Step down Transformer We use this 460V to 230V transformer to minimize possibility of arcing problems with a 460 Volt motor. 3) Gas Nozzles Solar Manufacturing uses machined tapered graphite nozzles throughout the main section of the hot zone and the front door. These very rugged nozzles are tapered to accelerate gas flow and are easily removable if one has to be replaced. Other designs use round Molybdenum sheet formed types which tend to lose their shape after a short time becoming brittle and nearly impossible to replace. H) POWER SUPPLY 1) Power Supply Type Solar Manufacturing normally uses a SCR type dry power supply with power trim controls within the control cabinet. Other equipment often includes a VRT water cooled type power supply. Although both systems perform satisfactorily for given applications, the dry system eliminates the possibility of water contamination and any resulting flow problems within the power transformer.

I) ELECTRICALS AND CONTROLS 1) Control Cabinet Solar Manufacturing prefers to house electrical controls in one standard 6 x 6 Standard NEMA 12 Cabinet which meets NFPA 70 Standard and includes an integrated main electrical switch interlock. Other designs often split the controls into many, various smaller cabinets thus making it more difficult to co ordinate operation and trouble shooting. 2) Controls and Instrumentation to simplify the operation and capabilities of our vacuum furnaces, we developed the SolarVac 4000/5000 systems of controls. Both incorporate user friendly touch screen capability to continually control and monitor furnace status and operation. Allen Bradley PLC equipment is provided with other front panel mounted instruments including a programmable controller, an over temperature controller, a paperless graphic recorder and a vacuum gauge controller, all housed within one cabinet. Other designs provide similar equipment, but usually use Siemans Type PLC systems which we have found to be much more difficult to program and modify. Other systems also often do not include auto tune or PID down load features which are very desirable for broad range temperature control. 3) Thermocouples We, and most other manufacturers, have standardized on Type S thermocouples for control and over temperature. Usually Type K thermocouples with appropriate jack panels are included for work monitoring and survey.

J) OTHER CRITICAL AREAS 1) Gas Backfill Valve Solar Manufacturing uses a standard ASCO type valve. It is important to specify this for proper gas backfill considerations and reliability. 2) Partial Pressure Operation Proper control of partial pressure is most important on many process cycles. Our furnaces are designed for auto control from 500 Microns Hg to 10 Torr. Equipment from other manufacturers often limits control to 1 Torr. Control above 1 Torr is important on processes where it is desirable to reduce chrome and copper evaporation at process temperatures over 1800 F. 3) Water Cooling Requirements Any equipment specification should state the required rates of water flow required during heating and cooling segments of a cycle. Pressure regulators should be included on furnace and supporting piping. Also, water flow sight indicators should be provided on all critical lines. 4) Heating and Cooling Rates The time to heat the empty furnace from ambient to 2000 F should be stated. We normally specify 5 minutes. In addition, an empty furnace cooling rate should be defined. We normally state a 5 minute time from 2000 F to 200 F. 5) Short Circuit Current Rating (SCCR) It is important that the furnace shall be designed and rated to accept possible short circuit current plant conditions. Installation of electrical equipment that has a short circuit rating (SCCR) lower than the available fault current of the electrical service is both a safety hazard and a violation of National Electrical Code.

K) PRE-SHIPMENT TESTING Every furnace must be manufactured to fully meet customer requirements and expectations. These requirements are normally written in an Equipment Specification document which becomes part of the overall purchase order documentation. The specification should not only highlight the various required hardware components but also highlight the overall performance expected of the equipment. In order to demonstrate that the furnace will perform as expected by the customer, Solar Manufacturing does a thorough and complete test of the system. These tests include: 1) Complete electrical check-out and debugging of all related components and systems. 2) Heating of equipment to demonstrate optimum heating temperature (bake-out). 3) A complete Temperature Uniformity Survey (TUS) to illustrate uniformity throughout the hot zone. 4) A gas cooling demonstration to confirm cooling rates required of the furnace. 5) Other specific tests required by the specifications. Please note that many manufacturers are unable or reluctant to perform these tests prior to shipping the equipment.

ATMOSPHERES Solar Atmospheres Eastern PA Plant A 1969 Clearview Road, Souderton, PA 18964 p. 800.347.3236 Solar Atmospheres Eastern PA Plant B 255 Township Line Road, Hatfield, PA 19440 p. 800.347.3236 Solar Atmospheres Western PA 30 Industrial Road, Hermitage, PA 16148 p. 866.982.0660 Solar Atmospheres CA 8606 Live Oak Avenue, Fontana, CA 92335 p. 866.559.5994 www.solaratm.com Copyright 2012 Rev. 9/12 1983 Clearview Road, Souderton, PA 18964 p. 267.384.5040 www.solarmfg.com