ELFOENERGY LARGE 2 TECHNICAL BULLETIN HIGH EFFICIENCY AIR-COOLED LIQUID CHILLER FOR OUTDOOR INSTALLATION WSAT-XEE SERIES

Similar documents
ELFOEnergy Extended Inverter

ELFOEnergy Duct Inverter

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

SPINchiller 3. Technical Bulletin. R-410A modular scroll technology. Two independent refrigeration circuits. Partial recovery of the condensing heat

ELFOEnergy SHEEN. Technical Bulletin. Air source inverter heat pump for outdoor installation. WSAN-XSi RANGE HIGH SEASONAL EFFICIENCY

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

ELFOEnergy Ground. Technical Bulletin. Water cooled heat pump for indoors installation WSHN-EE RANGE

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

WSAN-XEE AIR TO WATER HEAT PUMP FOR OUTDOOR INSTALLATION

ELFOEnergy Extended Inverter

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

Packaged air cooled liquid chillers for outdoor installation kw. technicalcatalogue T_EGL_1012_GB

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS

WSAT-EE AIR COOLED WATER CHILLER FOR OUTDOOR INSTALLATION

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

ELFOEnergy Ground Medium 2 - Multifunction

WATER TO AIR DUCTABLE INDOOR HORIZONTAL HEAT PUMP

VERSATEMP EQV-X TECHNICAL BULLETIN DIRECT EXPANSION HIGH EFFICIENCY PACKAGED AIR CONDITIONER EQV-X 3-21 SERIES WATER-AIR HEAT PUMP

AIR TO WATER HEAT PUMP FOR OUTDOOR INSTALLATION. Size

kw COOLING kw HEATING

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw. Scroll Compressors SCAEY-FC DE 98

ELFOEnergy Magnum - Heat pump

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

Water chillers water/water type SIGMA Technical information manual

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw. Scroll Compressors SCAEY-FC DE 98

kw. technicalcatalogue

44,9 202,0 kw. technicalcatalogue

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

EKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

Blue Box Epsilon Echos +

EQSL TECHNICAL CATALOGUE AIR COOLED WATER CHILLER UNITS AXIAL FANS. Models: 300 V2 F V2 F16. Cooling capacity: 299 to 1310 KW

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

Air cooled chillers. Air cooled chillers with brushless oil-free compressors. RAC. Ka Series - 1 or 2 cooling circuits capacity from 300 to 1400 kw

Galletti Water chillers and heat pumps catalogue

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

EQEF TECHNICAL CATALOGUE AIR COOLED WATER CHILLERS AXIAL FANS WITH FREE-COOLING SYSTEM

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

BRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.

HYDRONIC System. HYDRONIC System. The complete range of chillers, heat pumps and air handling units in large installations

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10

BRH. Climaveneta Technical Bulletin. Water-cooled liquid chillers ,5-35,1 kw. Versatile High efficiency Maximum silent-running

LCP kw. Outdoor monobloc air-water unit. Total heat recovery multi-purpose units LCP PLUS

pyxis pyxisa NEW rcgroupairconditioning

BETA ECHOS. Air/water cooled chillers and heat pumps kw. General BETA ECHOS is a range of chillers and ductable air-water heat pumps.

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 9 to 18 KW

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

pyxis cla pyxis cla A-CLASS NEW rcgroupairconditioning

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

pyxis u pyxis ua NEW rcgroupairconditioning

GLIDER EVO FREE GLIDER EVO FREE GLYCOL FREECOOLING. rcgroupairconditioning

Modular Air-cooled Chillers

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient

RTA TECHNICAL MANUAL AIR-WATER CHILLERS AND HEAT PUMPS FOR OUTDOOR INSTALLATION O L S E A F RA N

Air-to-water scroll chillers

CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw

LSK LSK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

Next P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB

LDK LDK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

Aquaflair TRAC-TRAF-TRAH

PYXIS U PYXIS U. rcgroupairconditioning

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

KELVIN Clim F497. Kelvin air conditioning

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

ERAH MC Ka. Range kw. AIR COOLED CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS FOR OUTDOOR INSTALLATION (Standard line)

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

LER kw. Indoor motor-driven evaporating units. Motor-driven evaporating units LER PLUS

black Thermal power (A7:W45) kw Cooling power (A35;W7) kw

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

VULCAN AIR TO WATER HEAT PUMP FOR OUTDOOR INSTALLATION

GLIDER EVO GLIDER EVO. rcgroupairconditioning

O L R E RGA ST RA N AIR-WATER CHILLERS AND HEAT PUMPS FOR OUTDOOR INSTALLATION TECHNICAL MANUAL

AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw

LSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES

LZT High efficiency air to water heat pumps with E.V.I. compressors

GLIDER EVO CLA GLIDER EVO CLA HIGHEFFICIENCY ACLASS. rcgroupairconditioning

CRIMSON & CRIMSON MAX


PRODUCT GUIDE

SMARTPACK is the high efficiency packaged roof top air conditioning unit designed to provide make-up air and the energy recovery in the served zone.

SPLIT System. SPLIT System Simple and flexible direct expansion solutions for the commercial sector and industry

COOLROW Close control air conditioners for In-Row installation Cooling Capacity: kw

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw

AQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual

EQPHU PACKAGED HEAT PUMP AIR/ WATER LIQUID CHILLER FOR OUTDOOR INSTALLATION

pyxis hp "u" pyxis hp "u" IDEA NEW rcgroupairconditioning

Technical Catalogue. Multi-Scroll Air-Cooled Liquid Chillers. Nominal cooling capacity: kw 50 Hz

1

CIATCOOLER LJA. Chilled water production units USE. Attractive design, Compact and quiet

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

30RH B Nominal cooling capacity kw Nominal heating capacity kw

Transcription:

TECHNICAL BULLETIN ELFOENERGY LARGE HIGH EFFICIENCY AIR-COOLED LIQUID CHILLER FOR OUTDOOR INSTALLATION WSAT-XEE SERIES Nominal cooling capacity from to kw ELFOEnergy LARGE is a highly energy efficient liquid chiller which is equipped with Scroll compressors, large heat-exchange surfaces and electronically controlled fans. Thanks to its excellent partial-load performance, its ESEER seasonal efficiency is at the top of its category, enabling great savings on management costs over the entire annual cycle. Furthermore, the standard EXCELLENCE version is in energy efficiency Class A at full-load. ELFOEnergy LARGE is also available in the PREMIUM compact version, which has been optimized to reduce on the initial investment. It can be equipped with several built-in accessories, like pump groups, an energy recovery device and an inertial buffer. ELFOEnergy LARGE is, therefore, the centralised solution for all applications which require high performance, working continuity and management costs reduction. BTC00GB-0

ELFOENERGY LARGE COST OR RELIABILITY? THE DILEMMA OF MODERN SYSTEM ENGINEERING APPLICATIONS Air-conditioning systems in trade centres influence both the starting investment and monthly management costs, for the whole of their working lives. This theme is even more relevant in residential applications with centralised systems. Furthermore, maximum working flexibility requirements should be added to that, in serving different users while avoiding wasting energy and thus, money. Finally, there are several industrial applications which require chilled water as service fluid, process fluid or vector fluid for operator comfort and for conserving goods and enabling cycles to function correctly. Furthermore, in all these cases, the working reliability of the system is decisive. THE HIGH EFFICIENCY HYDRONIC SYSTEMS ARE EXTREMELY VERSATILE, RELIABLE AND WIDESPREAD Despite their apparently low costs, split, multi-split and VRF direct expansion systems have a lot of limits in these applications. For example, they require a separate system for primary air treatment. The pipes that contain the refrigerant cross the served rooms and therefore they are subject to restrictions and use limitations. They cannot operate in the freecooling mode, the high efficiency and convenient mode that allows energy savings. the hydronic systems are certainly more complete and versatile. They make it possible to adopt various types of terminals in the served environment, from fan coil units exposed or integrated in the furnishings, up to radiant or induction systems. They are also irreplaceable in the service and process industrial applications. The main component performances, like air-cooled liquid chiller, are checked and certificated by Eurovent. CLIVET CHILLERS REDUCE CONSUMPTION AND ARE COMPACT AND RELIABLE With over twenty years of technological evolution, Clivet liquid chillers and heat pumps represent the state of the art in air-conditioning in residential, trade and industrial environments. Their success is based on high energy efficiency, compactness and management and maintenance simplicity, with wide versatility in the choice of the most suitable model for the specific use. BTE00GB-0

ELFOENERGY LARGE ELFOEnergy LARGE PROVIDES ALL CLIVET TECHNOLOGICAL DEVELOPMENTS FOR THEIR MEDIUM CAPACITY HYDRONIC SYSTEMS High-efficiency Scroll compressors, high-performance heat exchangers, electronically-controlled fans, completely automatic functions: this is just is some of the technology available in ELFOEnergy LARGE, in a range of models which are ideal for trade, residential and industrial medium capacity air-conditioning. The two available versions enable the best combination to be chosen between initial investment and entire life cycle system costs. The EXCELLENCE version has a very high energy efficiency while working both at partload and full-load (Eurovent class A certificate at full load) The PREMIUM version has a high-level of compactness and high-efficiency at partial load. Furthermore, ELFOEnergy Large with its numerous configurations, can be completed with most common system options built-in. COMPETITIVE ADVANTAGES High efficiency all year round ELFOEnergy LARGE reduces the annual energy consumption thanks to its high partial load efficiency, or the more frequent operating conditions in the system life cycle. So the value of the building served increases. The main components are manufactured in large numbers on industrial scale, with the maximum structural reliability and spare parts availability series. System simplification All of the features are provided by Clivet already assembled and tested onboard, differently then other manufacturers who make numerous additional components available to be installed on site. Compact and versatile Suitable for all types of terminals, from the fan systems to the radiant and chilled beams, also ELFOEnergy LARGE has a extremely low noise configuration, hat energy recovery for the production of free domestic hot water, Master-Slave management devices. BTE00GB-0

ELFOENERGY LARGE ELFOEnergy LARGE TECHNOLOGY IS THE ENERGY REFERENCE POINT FOR LIQUID CHILLERS MAXIMUM EFFICIENCY IS ASSURED BETWEEN THE % AND THE % OF THE SYSTEM LOAD For maximum loads taking place only for a few hours of functioning per year. The high efficiency at partial loads of ELFOEnergy LARGE makes it much more competitive and efficient than other solutions. THE MODULAR SCROLL IS THE EXCELLENT SOLUTION FOR PARTIAL LOAD * EUROVENT (ESEER) supply times reference and ARI (IPLV) reference for seasonal efficiency calculations. ELFOEnergy LARGE uses Scroll-type high-efficiency compressors, with optimized spirals. Main advantages are: Compressors manufactured in large numbers at industrial level, with strict quality checks and highest reliability thanks to the elevated production volumes. With two different-sized compressors, in order to achive more adjustment steps. So it is possible to supply for usage only the energy that is actually require. Efficiency increases by over 0% when operating at partial loads, thanks to the larger heat exchange surfaces available. The electronic expansion valve contributes to the excellent performance (EEV) it adapts rapidly and precisely to the actual load required for usage, and the high performance heat exchangers. Example refers to a WSAT-XEE, EXCELLENCE. Version. External temperature equal to C / 0 C / C, respectively. VERY HIGH HEAT EXCHANGE EFFICIENCY Thanks to the external ELFOEnergy LARGE coils, equipped with wide frontal surfaces and reduced depth, the following is obtained: An improvement in the working temperature of the chiller circuit and, therefore, its efficiency, since the approach between the air temperature and the temperature of the chiller fluid inside the exchanger is reduced; A reduction in consumption by the fans, thanks to the reduced depth of the exchanger which decreases air flow renewal drops. Furthermore, the automatic fan speed control, supplied in series, minimises the air renewal air requirement to function correctly and therefore further reduces consumption; A decrease in the sound level, since greater surfaces enable slower air speed in the exchangers. ECOBREEZE ELECTRONICALLY-CONTROLLED FAN TECHNOLOGY The external axial fans are equipped with an innovative Winglet blade profile with an integrated deflector, which is able to increase aerodynamic efficiency. This results in a % reduction in consumption. The average acoustic emission is db less then traditional fans. Using ECOBREEZE the external rotary electric motor is operated by a continuous magnetic switching of the stator, induced by integrated electronic control. The advantages are: 0% increase in efficiency thanks to the brushless technology and the special electricity supply; Increase in the working life, thanks to the elimination of the brush wear; Reduction in the electrical consumption by the system, thanks to a drastic reduction of the inrush current for the fans obtained using the integrated Soft start function. Note: ECOBREEZE is supplied as standard in the EXCELLENCE version COMPLETELY AUTOMATIC FUNCTIONING The microprocessor controller manages functioning automatically in line with maximum efficiency criteria, enables up to units to be coordinated in a local network (Master-Slave function) and includes numerous safety functions and the management of any alarms. The interface terminal is equipped with a backlit graphic display and a multifunction access keyboard. The multi-level menu is protected by passwords which are differentiated by different user types. The daily / weekly clock programmer function is standard. Thanks to its attractive design, the interface terminal can also be positioned inside the rooms being serviced or in a special system control room. BTE00GB-0

ELFOENERGY LARGE ELFOEnergy LARGE TECHNOLOGY ENABLES THE SYSTEM TO BE INDUSTRIALISED ELFOEnergy LARGE can be supplied complete with system components which are often provided as external to units. Thus reducing: Design time: all the accessories are created to guarantee the best overall performance; Installation costs: the accessories which are already connected manually, electrically wired and individually checked are ready to start working immediately; Dimension: integration of system members into the unit reduces technical spaces and increases the space available for other uses. The slim line structure enables it to be positioned even on terraces or in external service corridors. THE ON-BOARD PUMPS ARE VERSATILE, READY-FOR-USE AND RELIABLE The various solutions available are: Standard pump, with a wide range of available heads. Standard pump with emergency pump. The on-board microprocessor balances its working hours and in case of any breakdown signals the fault and automatically activates the reserve pump. HYDROPACK, the modular solution with two parallel pumps. Automatically reduces water flow in critical conditions, avoiding blocks due to overloading and consequential interventions by specialised technical personnel. It is very useful during start-up, during re-start after a pause in working (e.g. a weekend) or after a long period of inactivity. In case of any pump breakdowns, the unit continues to function with 0% of the nominal flow. EVEN THE STORAGE TANK AND THE PRIMARY CIRCUIT CAN BE INTEGRATED ON-BOARD A connection to the secondary use circuit is all that's needed. In this way, the system results even more simple and reliable. The units are complete with rapid connections on the hydraulic side, which further reduces set-up times by eliminating pipe threading operations. Furthermore, other system components are also available as accessories, such as hydraulic attachments reported on the external walls of the unit (as standard with pumps and/or storage tank) and the required water filter. ELFOEnergy LARGE MAY INCLUDE MOST OF SYSTEM COMPONENTS STANDARD RAPID CONNECTIONS Gasket Housing Groove Bolt/Nut FREE HOT WATER Condensation heat recovery: Partial: recovers around 0% of the available heat (desuperheater); Total: recovers 0% of available heat. Free hot water production for : Supplying hot-water coils for post-heating; Producing domestic hot water (with the intermediate exchanger); Other processes or operations. IT EXPLOITS EXTERNAL AIR FOR COOLING WITHOUT ACTIVATING THE COMPRESSORS In the FREE-COOLING configuration, as soon as the external conditions enable it, the unit is able to cool the liquid reducing compressor functioning up to their complete withdrawal. This configuration is particularly useful in applications with a high number of room loads, since it notably reduces unit energy consumption and compressor wear. BTE00GB-0

ELFOENERGY LARGE INDEX OF THE TECHNICAL SECTION EXCELLENCE Version - Soundproof compressor configuration (SC) General technical specification - Electrical data Pag. Operating limit (COOLING) - Sound level Pag. COOLING performance Pag. - Internal exchanger pressure drop - Admissible water flow rate Pag. EXCELLENCE Version - Extremely low noise configuration (EN) General technical specification - Electrical data Pag. Operating limit (COOLING) - Sound level Pag. COOLING performance Pag. - Internal exchanger pressure drop - Admissible water flow rate Pag. PREMIUM Version - Soundproof compressor configuration (SC) General technical specification - Electrical data Pag. Operating limit (COOLING) - Sound level Pag. COOLING performance Pag. - Internal exchanger pressure drop - Admissible water flow rate Pag. PREMIUM Version - Extremely low noise configuration (EN) General technical specification - Electrical data Pag. 0 Operating limit (COOLING) - Sound level Pag. COOLING performance Pag. - Internal exchanger pressure drop - Admissible water flow rate Pag. CONFIGURATIONS Pag. - HYDRONIC GROUP ACCESSORIES Pag. - HYDROPACK Pag. - ACCESSORIES Pag. - FOULING CORRECTION FACTOR - CALIBRATION - EXCHANGER OPERATING LIMITS Pag. OPTION COMPATIBILITY Pag. 0- DIMENSIONAL Pag. - CONFIGURATION CODE () () () () () () WSAT-XEE EXC - - - SC PED EXC - - - SC PED PRM D R B FCD EN CLV () VERSION EXCELLENCE (EXC) standard PREMIUM (PRM) () ENERGY RECOVERY Energy recovery: not required (-) standard Partial energy recovery (D) Total energy recovery (R) () LIQUID LOW TEMPERATURE Liquid low temperature : not required (-) standard Liquid low temperature (B) () FREE-COOLING Direct FREE-COOLING: not required (-) standard Direct FREE-COOLING (FCD) () ACOUSTIC CONFIGURATION Acoustic configuration with compressor soundproofing (SC) standard Extremely low noise acoustic configuration (EN) () HEAT EXCHANGERS APPROVALS Heat exchangers approvals CE = PED (European Testing) (PED) standard Heat exchangers approvals C = CLIVET (Internal Testing) (CLV) standard BTE00GB-0

ELFOENERGY LARGE TECHNICAL UNIT FEATURES - EXCELLENCE VERSION COMPRESSOR Hermetic orbiting scroll compressor complete with motor over-temperature and over-current devices and protection against excessive gas discharge temperature. Fitted on rubber antivibration mounts and complete with oil charge. A oil heater is automatically switched on at the compressor shut-down to prevent oil dilution by the refrigerant. The compressors are connected in tandem on a single refrigerator circuit. They have bi-phase equalization of the oil and are equipped with cut-off bibcock. STRUCTURE Supporting structure realised in galvanised steel sheet able to supply excellent mechanical features and long-lasting resistance to corrosion. PANELLING External panels in pre-painted aluminium especially indicated in outdoor installation due to its superior resistance to corrosion avoiding periodic painting. Side panels are easily removable and allow complete access to unit components. Internal sound proof lining reduces sound pressure levels. INTERNAL EXCHANGER Direct expansion heat exchanger, braze-welded AISI stainless steel plates with large exchange surface and complete with external heat and anticondensate insulation. The exchanger comes complete with: - differential pressure switch, water side - antifreeze heater to protect the water side exchanger, preventing the formation of frost if the water temperature falls below a set value. EXTERNAL EXCHANGER Finned exchanger, made from copper pipes arranged in staggered rows and mechanically expanded for better adherence to the collar of the fins. The fins are made from aluminium with a special corrugated surface, set a suitable distance apart to ensure maximum heat exchange efficiency. The coils are complete with integral subcooling circuit which assures the correct refrigerant feeding of the expansion valve. FAN ECOBREEZE device (STD) Helical fans with sickle-shaped blades with "Winglets" at the end, coupled directly to electronic control (IP ), driven by the magnetic commutation of the stator. The brushless technology and the special supply increase both the life expectancy and the efficiency. As a result the electric consumption is reduced up to 0%. Fans are housed in aerodynamically shaped structures to increase efficiency and reduce noise level. The assembly is protected by accident prevention guards. The fans have the variable speed control. REFRIGERANT CIRCUIT The circuit is complete with: - replaceable anti-acid solid cartridge dehydrator filter - sight glass with moisture indicator - electronic expansion valve - high pressure switch - low pressure switch - high pressure safety valve - low pressure safety valve - liquid line shut-off valve - compressor discharge shut-off valve ELECTRICAL PANEL The Power Section includes: - main door lock isolator switch - isolating transformer for auxiliary circuit power supply - compressor circuit breaker - fan overload circuit breakers - compressor control contactor The control section includes: - interface terminal with graphic display - display of the set values, the error codes and the parameter index - ON/OFF and alarm reset buttons - proportional + integral water temperature control - antifreeze protection on the water side - compressor overload protection and timer - pre-alarm function for water anti-ice and high refrigerant gas pressure - self-diagnosis system with immediate display of the error code - automatic compressor start rotation control - compressor operating hour display - remote ON/OFF control - relay for remote cumulative fault signal - input for demand limit (absorbed power limit according to an external signal 0 V or 0mA) - Master-Slave function - serial port RS with Modbus protocol TECHNICAL UNIT SPECIFICATIONS - PREMIUM VERSION Technical specifications like EXCELLENCE version, except fan FAN Helical fans with sickle-shaped blades with "Winglets" at the end, coupled directly to a three phase electric external rotor motor with thermal protection incorporated in version IP. Housed in aerodynamically shaped nozzles to increase efficiency and minimize noise levels. They are fitted with protective safety guard grilles. The fans have the variable speed control. CONSTRUCTIVE CONFIGURATIONS - D Partial Energy recovery - R Total Energy recovery - B Low temperature liquid - SC Acoustic configuration with compressor soundproofing - EN Extremely low noise acoustic configuration - FCD Direct FREE-COOLING ACCESSORIES - HYDRONIC GROUP - Standard pump (note: different type of pumps are available according to the head) - Standard pump with a reserve pump (note: are type of pumps are available according to the head) - HYDROPACK (note: type of pumps are available according to the head) - Storage tank - Storage tank with primary circuit on board (note: only for unit with standard pump / standard pump with reserve pump ) - hydraulic couplings on external panel (note: only for unit with standard pump / standard pump with reserve pump / Hydropack and/ or Storage tank) - stainless steel mesh mechanical filter (separately provided accessory) (note: The filter must be installed in the exchanger inlet. Clivet declines all responsibility and the warranty on the equipment automatically expires if it is not provided an suitable mechanical filter within the unit). ACCESSORIES - Finned coil protection grilles - Anti-hail protection grilles - Copper/aluminium condenser coil with acrylic coating - Copper/aluminium condenser coil with Fin Guard (Silver) treatment - Copper/copper condenser coil - Spring antivibration mounts (separately provided accessory) - Electrical panel ventilation - Electrical heating (for electrical panel heating) - Phase monitor - Power factor correction capacitors (cosfi > 0.) - Breakaway current reducing device (soft start) - High and low pressure gauges - Shut-off valve on compressor suction and discharge - Device for fan consumption reduction of the external section with variable speed (phase-cutting) (only for the EXCELLENCE version) - Free contacts for compressor state - Free contacts for compressor state and for operation in local/remote mode - Set point compensation with 0- V signal - Set point compensation with -0 ma signal - Set point compensation with outside temperature probe - Set point compensation according to the outside enthalpy - Kit for remote microprocessor remote control interface (separately provided accessory) - BACnet Converter - LonWorks serial converter kit TEST All the units are factory-tested in specific steps, before shipping them. After the approval, the moisture contents present in all circuits are analyzed, in order to ensure the respect of the limits set by the manufacturers of the different components. BTE00GB-0

ELFOENERGY LARGE VERSION: EXCELLENCE ACOUSTIC CONFIGURATION: SOUNDPROOFING COMPRESSOR (SC) ELFOEnergy LARGE GENERAL TECHNICAL SPECIFICATIONS (SERIES WSAT-XEE) SIZE 0 0 0 0 0 COOLING Cooling capacity kw, Compressor power input kw,,, 0,, 0,,, Total power input kw,,,,,,, 0, Heating capacity total recovery kw Heating capacity partial recovery kw,,,,,,, 0, EER,,,,,,,,, ESEER,,,,,,,,, COMPRESSOR Type of compressors Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll N. of Compressors Nr Nominal capacity HP 0 0 0 0 0 Standard capacity steps Nr Oil charge l Refrigerant circuits Nr INTERNAL EXCHANGER Type of internal exchanger PHE PHE PHE PHE PHE PHE PHE PHE PHE Water flow rate (Internal Exchanger) l/s,,,,,,,,, Internal exchanger pressure drop kpa 0 0 0 0 0 Water content l EXTERNAL SECTION FANS Type of fans AX AX AX AX AX AX AX AX AX Number of fans Nr Standard air flow l/s CONNECTIONS Water fittings " / " / " / " / " / " / " / " / " / POWER SUPPLY Standard power supply 00/~/0 00/~/0 00/~/0 00/~/0 00/~/0 00/~/0 00/~/0 00/~/0 00/~/0 DIMENSIONS Length mm 0 0 0 0 0 0 0 0 0 Depth mm Height mm STANDARD UNIT WEIGHTS Shipping weight kg 0 Operating weight kg 0 0 () data referred to the following conditions : - internal exchanger water = / C - external exchanger air intake C () According to EUROVENT the Total Power Input does not consider the pump share, required to overcome the pressure drop for the solution circulation inside the exchangers. () Option. recovery exchanger water = 0 / C () PHE = plates () AX = axial-flow fan ELECTRICAL DATA ELFOEnergy LARGE (SERIES WSAT-XEE) SIZE 0 0 0 0 0 F.L.A. - FULL LOAD CURRENT AT MAX ADMISSIBLE CONDITIONS F.L.A. - Total A, 0, 0,,,, F.L.I. FULL LOAD POWER INPUT AT MAX ADMISSIBLE CONDITION F.L.I. - Total kw,,,,,,, M.I.C. MAXIMUM INRUSH CURRENT M.I.C. - Value A,,,,,, 0, 0,, Voltage unbalance: max % Power supply: 00//0 Hz +/-% Electrical data refer to standard units; according to the installed accessories, the data can suffer light variations. BTE00GB-0

To ( C) SIZE ELFOENERGY LARGE VERSION: EXCELLENCE ACOUSTIC CONFIGURATION: SOUNDPROOFING COMPRESSOR (SC) OPERATING LIMITS (COOLING) SIZE 0 0 0 0 0 EXTERNAL EXCHANGER Max air intake temperature C Max air intake temperature C 0 0 0 0 0 0 0 0 0 Min. air intake temperature C - - - - - - - - - Min. air intake temperature C - - - - - - - - - Min. air intake temperature C - - - - - - - - - Min. air intake temperature C INTERNAL EXCHANGER Max water inlet temperature C Min. water outlet temperature C Min. water outlet temperature C - - - - - - - - - Data referred to the following conditions : - internal exchanger water = / C - external exchanger air C - still air Warning: the still air condition is meant as absence of air flow to the unit. Any wind condition can let air pass through the condenser coil thus worsening the operating limits of the unit. In case of predominant winds, windbreak barriers are necessary. Note. For correct maintenance (not functioning) with external air temperatures at less than - C, the Standard unit (not the FREE-COOLING configuration) must be equipped with the "Electric panel anti-freeze protection" option and be continuously supplied with electricity. The hydraulic circuit must be filled with an adequate percentage of anti-freeze. In this condition, the minimum external air-temperature which is permitted depends on the chosen model of "Electric panel anti-freeze protection" option, up to a limit value of - C. The functioning mode can also be extended up to external air temperatures of less than - C, but only with a FREE-COOLING configuration which is complete with an adequately sized "Electric panel anti-frost protection" option. In the Standard unit (not the FREE-COOLING configuration) with an empty hydraulic circuit, which has no electricity supply, correct maintenance (not functioning) is possible up to an external air temperature of -0 C. () Max inlet temperature - unit at full load () Max inlet air temperature - Unit at partial load () Min inlet air temperature - Unit at full load and still fresh air () Min inlet air temperature - Unit at partial load and still fresh air () Min inlet air temperature - unit at partial load and air speed of 0. m/s. () Min inlet air temperature - unit at partial load and air speed of m/s. () Standard unit without low temperature liquid device and external exchanger air intake C () Unit with low temperature liquid device and external exchanger air intake C Fluid with ethylene glycol of 0%. 0 Graph informed to size. The detail of each size is shown in tabular date. Ta = external exchanger air intake temperature (dry bulb) To ( C) = internal exchanger water outlet temperature 0 -. Standard unit: (not with Low temperature liquid ). Low temperature liquid unit (with ethylene glycol of 0%). Partial-load unit (automatic capacity control). Full-load unit (automatic air flow modulation) - - - - 0 0 0 Ta ( C) SOUND LEVELS Sound Power Level (db) Sound pressure level Sound pressure level Sound power level 0 00 00 000 000 000 db(a) db(a) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 The sound levels refer to the unit at full load, in the rated test conditions. The sound pressure level refers to a distance of m from the external surface of the units operating in an open field. Measures, according to ISO regulations, are carried out on a reflecting surface, with respect to the EUROVENT / certification. Data referred to the following conditions: - internal exchanger water = / C - outdoor air temperature C BTE00GB-0

ELFOENERGY LARGE VERSION: EXCELLENCE ACOUSTIC CONFIGURATION: SOUNDPROOFING COMPRESSOR (SC) COOLING PERFORMANCE SIZE 0 0 0 To (ºC) EXTERNAL EXCHANGER AIR INTAKE TEMPERATURE (ºC) HEAT DROP C 0 0 kwf kwe kwf kwe kwf kwe kwf kwe kwf kwe kwf kwe,0,,,,,,0,,,,,,, 0,0,,,0,,,,,,,,,,,,,,,,,,,,,,0 0,,, 0,0,,,,,0,0,,,,, 0,,,,,,,,,,, 0, 0,,,,,,,,,, 0,,,,,,,,,,,,, 0,0,0,,,,,,,,,,,,,,,,,,,,0,0,,, 0,,,,,,,0,,,,,,, 0,,,,,,,,,0,,,,,,0, 0,,,,,,, 0,,,,,0,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,0,,,,,,, 0,,0,,,,, 0,,,0,,0,,,0,,,,, 0,0,,,,,0,,,,,0,,,,,,,,,,,,,,,,,0,,,,,,, 0,0,,0,,,, 0,,,,, 0,,0,,,, 0,0,,0 0,,, 0,,,,,, 0,,,,,,,,,,,,,,,0,,,,,,,, 0,,,, 0,,,,,,, 0,,,,,,,,,,,, 0,,,,,,,,,,,, 0,,,,,,0,,,,,,0,0,,0,, - -,,,,,,,,,,,,,,0,,,,,,,, 0,,,,,,,,,,,,,,,,, 0,,,,,,,,,,,0, 0,,0,,,,, - -,0,, 0,,,,,0,, - -,0,0,,,,,,,,,,,,,,,0 0,,,,,,,,,,,, 0,,,,,,,,,,,, 0,,,, 0,,, 0,,,0,,,,,,0 0,,,,,0 00,,,,,,,0 0,,, kwf = Cooling capacity in kw kwe = Compressor power input in kw To = Internal exchanger water outlet temperature in C BTE00GB-0

P [kpa] ELFOENERGY LARGE VERSION: EXCELLENCE ACOUSTIC CONFIGURATION: SOUNDPROOFING COMPRESSOR (SC) COOLING PERFORMANCE SIZE 0 0 To (ºC) EXTERNAL EXCHANGER AIR INTAKE TEMPERATURE (ºC) HEAT DROP C 0 0 kwf kwe kwf kwe kwf kwe kwf kwe kwf kwe kwf kwe 0,,, 0,0,,, 0,,,,,,, 00, 0,,,, 0,,,,,,, 0, 0,,,,,,,,,,,,, 0,,,,,,,, 0,0,,, 0,,,,,,0,,,,,,,, 0,,,,, 0,0,,,, 0,,,,,,,,,,,,0,, 00,,,,,,,,,,,, 0,,,,,,,,,,,,,, 0,,,,,,,,,,, 0,0 0,, 0,0,,,0 0,,,,, 0,,, kwf = Cooling capacity in kw kwe = Compressor power input in kw To = Internal exchanger water outlet temperature in C INTERNAL EXCHANGER PRESSURE DROP 0 0 0 0 0 0 0 0 0 0 THE AIR SIDE PRESSURE DROPS ARE RELATIVE TO THE MEDIUM AIR TEMPERATURE OF C Q = AIR FLOW [l/s] DP = PRESSURE DROP [kpa] 0 0 THE WATER FLOW RATE CAN BE CALCULATED WITH THE FOLLOWING FORMULA: 0 Q [l/s] = kwf / (, x DT) 0 kwf = COOLING CAPACITY [kw] DT = TEMPERATURE DIFFERENCE BETWEEN WATER INLET / OUTLET 0 Q [l/s] To the internal exchanger pressure drops must be added the pressure drops of the steel mesh mechanical filter that must be placed on the water input line. It is a device compulsory for the correct unit operation, and it is available as Clivet option (see the HYDRONIC GROUP ACCESSORIES). If the mechanical filter is selected and installed by the Customer, it is forbidden the use of filters with the mesh pitch higher than, mm, because they can cause a bad unit operation and also its serious damaging. ADMISSIBLE WATER FLOW RATE Min. (Qmin) and max. (Qmax) water flow-rates admissible for a correct unit operation. 0 0 0 0 0 Qmin [l/s],,,,,,,,, Qmax [l/s],0,,,,,,,, BTE00GB-0

ELFOENERGY LARGE VERSION: EXCELLENCE ACOUSTIC CONFIGURATION : EXTREMELY LOW NOISE (EN) ELFOEnergy LARGE GENERAL TECHNICAL SPECIFICATIONS (SERIES WSAT-XEE) SIZE 0 0 0 0 0 COOLING Cooling capacity kw, 0 Compressor power input kw,,,,,,, Total power input kw,,,,, 0,,, Heating capacity total recovery kw Heating capacity partial recovery kw 0 EER,,,,0,,,,, ESEER,,,,,,,,, COMPRESSOR Type of compressors Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll N. of Compressors Nr Nominal capacity HP 0 0 0 0 0 Standard capacity steps Nr Oil charge l Refrigerant circuits Nr INTERNAL EXCHANGER Type of internal exchanger PHE PHE PHE PHE PHE PHE PHE PHE PHE Water flow rate (Internal Exchanger) l/s,,,, Internal exchanger pressure drop kpa Water content l EXTERNAL SECTION FANS Type of fans AX AX AX AX AX AX AX AX AX Number of fans Nr Standard air flow l/s CONNECTION Water fittings " / " / " / " / " / " / " / " / " / POWER SUPPLY Standard power supply 00/~/0 00/~/0 00/~/0 00/~/0 00/~/0 00/~/0 00/~/0 00/~/0 00/~/0 DIMENSIONS Length mm 0 0 0 0 0 0 0 0 0 Depth mm Height mm STANDARD UNIT WEIGHTS Shipping weight kg 0 Operating weight kg 0 0 () data referred to the following conditions : - internal exchanger water = / C - external exchanger air intake C () According to EUROVENT the Total Power Input does not consider the pump share, required to overcome the pressure drop for the solution circulation inside the exchangers. () Option. recovery exchanger water = 0 / C () PHE = plates () AX = axial-flow fan ELECTRICAL DATA ELFOEnergy LARGE (SERIES WSAT-XEE) SIZE 0 0 0 0 0 F.L.A. - FULL LOAD CURRENT AT MAX ADMISSIBLE CONDITIONS F.L.A. - Total A, 0, 0,,,, F.L.I. FULL LOAD POWER INPUT AT MAX ADMISSIBLE CONDITION F.L.I. - Total kw,,,,,,, M.I.C. MAXIMUM INRUSH CURRENT M.I.C. - Value A,,,,,, 0, 0,, Voltage unbalance: max % Power supply: 00//0 Hz +/-% Electrical data refer to standard units; according to the installed accessories, the data can suffer light variations. BTE00GB-0

To ( C) SIZE ELFOENERGY LARGE VERSION: EXCELLENCE ACOUSTIC CONFIGURATION : EXTREMELY LOW NOISE (EN) OPERATING LIMITS (COOLING) SIZE 0 0 0 0 0 EXTERNAL EXCHANGE Max air intake temperature C Max air intake temperature C Max air intake temperature C 0 0 0 0 0 0 0 0 0 Min. air intake temperature C - - - - - - - - - Min. air intake temperature C - - - - - - - - - Min. air intake temperature C - - - - - - - - - Min. air intake temperature C INTERNAL EXCHANGE Max water inlet temperature C Min. water outlet temperature C Min. water outlet temperature C - - - - - - - - - Data referred to the following conditions : - internal exchanger water = / C - external exchanger air C - still air Warning: the still air condition is meant as absence of air flow to the unit. Any wind condition can let air pass through the condenser coil thus worsening the operating limits of the unit. In case of predominant winds, windbreak barriers are necessary. Note. For correct maintenance (not functioning) with external air temperatures at less than - C, the Standard unit (not the FREE-COOLING configuration) must be equipped with the "Electric panel anti-freeze protection" option and be continuously supplied with electricity. The hydraulic circuit must be filled with an adequate percentage of anti-freeze. In this condition, the minimum external air-temperature which is permitted depends on the chosen model of "Electric panel anti-freeze protection" option, up to a limit value of - C. The functioning mode can also be extended up to external air temperatures of less than - C, but only with a FREE-COOLING configuration which is complete with an adequately sized "Electric panel anti-frost protection" option. In the Standard unit (not the FREE-COOLING configuration) with an empty hydraulic circuit, which has no electricity supply, correct maintenance (not functioning) is possible up to an external air temperature of -0 C. () Max inlet temperature - unit at full load () Max inlet air temperature - Unit at partial load () Min inlet air temperature - Unit at full load and still fresh air () Min inlet air temperature - Unit at partial load and still fresh air () Min inlet air temperature - unit at partial load and air speed of 0. m/s. () Min inlet air temperature - unit at partial load and air speed of m/s. () Standard unit without low temperature liquid device and external exchanger air intake C () Unit with low temperature liquid device and external exchanger air intake C Fluid with ethylene glycol of 0% 0 Graph informed to size. The detail of each size is shown in tabular date. 0 - Ta = external exchanger air intake temperature (dry bulb) To ( C) = internal exchanger water outlet temperature. Standard unit: (not with Low temperature liquid ). Low temperature liquid unit (with ethylene glycol of 0%). Partial-load unit (automatic capacity control). Full-load unit (automatic air flow modulation) - - - - 0 0 0 Ta ( C) SOUND LEVEL Sound Power Level (db) Sound pressure level Sound pressure level Sound power level 0 00 00 000 000 000 db(a) db(a) 0 0 0 0 0 0 0 0 0 0 0 0 The sound levels refer to the unit at full load, in the rated test conditions. The sound pressure level refers to a distance of m from the external surface of the units operating in an open field. Measures, according to ISO regulations, are carried out on a reflecting surface, with respect to the EUROVENT / certification. Data referred to the following conditions: - internal exchanger water = / C - outdoor air temperature C The sound levels indicated sideways are valid only for the operating range of the Extremely low noise EN configuration; with fresh air temperatures higher and in any case into the operating range of the Compressor soundproofing SC configuration, consider the sound levels of the Compressor soundproofing configuration. BTE00GB-0

ELFOENERGY LARGE VERSION: EXCELLENCE ACOUSTIC CONFIGURATION : EXTREMELY LOW NOISE (EN) COOLING PERFORMANCE SIZE 0 0 0 To (ºC) EXTERNAL EXCHANGER AIR INTAKE TEMPERATURE (ºC) HEAT DROP C 0 0 kwf kwe kwf kwe kwf kwe kwf kwe kwf kwe kwf kwe,,,,,, 0, 0,,,,,,,,,,0,, 0,,,,,,,,,0,,,0,0,,,,,,0 0,,,,,,,,,,,,,0,,,,,,,,,,,,, 0,0,,,,,,,0,,,,,0,,,,,,,,,,,,,,,,,,,,,, 0,,,,,,,,,0,,, 0,,, 0,,0,,,,,,, 0,,,,,,,,,,,, 0,,,,,,0,0,,, 0,,,,0,,0,,,,,, 0,,,,,, 0,,,,,,,,0,,,0, 0,,0,,,,,,,,,,0 0,,,,,,0,,,,,, 0,,,,, 0,,,0,,, 0, 0,,,0,, 0, 0,,,,,0, 0,,,0,,,0 0,,,,,,0 0,,0,,,,,,,,,,,,,,,,,,,,,,,,,,,,, 0,,,,,,,,,0,,,,,,,,,,,,, 0,,,,,,,0,,,,,0,,,, 0,,,,,,,,,0,,,,,0,,0,, 0,0,,,,,,, 0,,,0,,,,0,,0,,,,, 0,,, 0,,,,,,,0,0,,, 0, 0,,0,,,,,,,,,,,,,,,,,, 0,,,,,,,,,,,0, 0,,,,,,,,,,, 0, 0,,,,,,,0,0,,,,,0,,,,,,,,,,,0,,,,,,,,,,,,,,,,,,,,,,,,0,0, 0,,,,,,,,,,,, 0,,,,,,,0,,,,, 0,,,,,,,,,,,,,,, 0,,,,,,,,,,,, kwf = Cooling capacity in kw kwe = Compressor power input in kw To = Internal exchanger water outlet temperature in C BTE00GB-0

P [kpa] ELFOENERGY LARGE VERSION: EXCELLENCE ACOUSTIC CONFIGURATION : EXTREMELY LOW NOISE (EN) COOLING PERFORMANCE SIZE 0 0 To (ºC) EXTERNAL EXCHANGER AIR INTAKE TEMPERATURE (ºC) HEAT DROP C 0 0 kwf kwe kwf kwe kwf kwe kwf kwe kwf kwe kwf kwe,0,,0,,,,,,,,,,,,,,,,,,,,, 0,,,,,,,,,,,,,, 0,,,,,0,,,,,,, 0,,,,,,,,,0 0,, 0,0,, 0,,,,,,, 0,,, 0,,,,,,,,,,,,,0, 0,,,,,,0,,0,0, 0, 0, 0,,,0,,,,,,,,0 0,,, 0,,,,,,,,,,,0, 0,, 0,0, 00,0,,, 0,,,,,,,, 0,0 0, kwf = Cooling capacity in kw kwe = Compressor power input in kw To = Internal exchanger water outlet temperature in C INTERNAL EXCHANGER PRESSURE DROP 0 0 0 0 0 0 0 0 0 0 THE AIR SIDE PRESSURE DROPS ARE RELATIVE TO THE MEDIUM AIR TEMPERATURE OF C Q = AIR FLOW [l/s] DP = PRESSURE DROP [kpa] 0 0 0 THE WATER FLOW-RATE CAN BE CALCULATED WITH THE FOLLOWING FORMULA Q [l/s] = kwf / (, x DT) 0 kwf = COOLING CAPACITY [kw] DT = TEMPERATURE DIFFERENCE BETWEEN WATER INLET / OUTLET 0 Q [l/s] To the internal exchanger pressure drops must be added the pressure drops of the steel mesh mechanical filter that must be placed on the water input line. It is a device compulsory for the correct unit operation, and it is available as Clivet option (see the HYDRONIC GROUP ACCESSORIES). If the mechanical filter is selected and installed by the Customer, it is forbidden the use of filters with the mesh pitch higher than, mm, because they can cause a bad unit operation and also its serious damaging. ADMISSIBLE WATER FLOW-RATE Min. (Qmin) and max. (Qmax) water flow-rates admissible for a correct unit operation. 0 0 0 0 0 Qmin [l/s],,,,,,,,, Qmax [l/s],0,,,,,,,, BTE00GB-0

ELFOENERGY LARGE VERSION: PREMIUM ACOUSTIC CONFIGURATION: SOUNDPROOFING COMPRESSOR (SC) ELFOEnergy LARGE GENERAL TECHNICAL SPECIFICATIONS (SERIES WSAT-XEE) SIZE 0 0 0 0 0 COOLING Cooling capacity kw, 0 Compressor power input kw,,, 0,,, 0,, Total power input kw,,,,,, 0,,, Heating capacity total recovery kw 0 Heating capacity partial recovery kw 0,, 0,,,, 0,, EER,,,,,,,,, ESEER,0,,0,,,,0,, COMPRESSOR Type of compressors Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll N. of Compressors Nr Nominal capacity HP 0 0 0 0 0 Standard capacity steps Nr Oil charge l Refrigerant circuits Nr INTERNAL EXCHANGER Type of internal exchanger PHE PHE PHE PHE PHE PHE PHE PHE PHE Water flow rate (Internal Exchanger) l/s,,,,,,,,, Internal exchanger pressure drop kpa Water content l EXTERNAL SECTION FANS Type of fans AX AX AX AX AX AX AX AX AX Number of fans Nr Standard air flow l/s 00 CONNECTION Water fittings " / " / " / " / " / " / " / " / " / POWER SUPPLY Standard power supply 00/~/0 00/~/0 00/~/0 00/~/0 00/~/0 00/~/0 00/~/0 00/~/0 00/~/0 DIMENSION Length mm 0 0 0 Depth mm Height mm STANDARD UNIT WEIGHTS Shipping weight kg Operating weight kg 0 (() data referred to the following conditions : - internal exchanger water = / C - external exchanger air intake C () According to EUROVENT the Total Power Input does not consider the pump share, required to overcome the pressure drop for the solution circulation inside the exchangers. () Option. recovery exchanger water = 0 / C () PHE = plates () AX = axial-flow fan ELECTRICAL DATA ELFOEnergy LARGE (SERIES WSAT-XEE) SIZE 0 0 0 0 0 F.L.A. - FULL LOAD CURRENT AT MAX ADMISSIBLE CONDITIONS F.L.A. - Total A, 0, 0,,,,,, F.L.I. FULL LOAD POWER INPUT AT MAX ADMISSIBLE CONDITION F.L.I. - Total kw,,,,, 0,,, 0, M.I.C. MAXIMUM INRUSH CURRENT M.I.C. - Value A,,,,, 0,, 0, Voltage unbalance: max % Power supply: 00//0 Hz +/-% Electrical data refer to standard units; according to the installed accessories, the data can suffer light variations. BTE00GB-0

To ( C) SIZE ELFOENERGY LARGE OPERATING LIMITS (COOLING) VERSION: PREMIUM ACOUSTIC CONFIGURATION: SOUNDPROOFING COMPRESSOR (SC) SIZE 0 0 0 0 0 EXTERNAL EXCHANGER Max air intake temperature C Max air intake temperature C 0 0 0 0 0 0 0 0 0 Min. air intake temperature C - - - - - - - - - Min. air intake temperature C - - - - - - - - - Min. air intake temperature C - - - - - - - - - Min. air intake temperature C INTERNAL EXCHANGER Max water inlet temperature C Min. water outlet temperature C Min. water outlet temperature C - - - - - - - - - Data referred to the following conditions : - internal exchanger water = / C - external exchanger air C - still air Warning: the still air condition is meant as absence of air flow to the unit. Any wind condition can let air pass through the condenser coil thus worsening the operating limits of the unit. In case of predominant winds, windbreak barriers are necessary. Note. For correct maintenance (not functioning) with external air temperatures at less than - C, the Standard unit (not the FREE-COOLING configuration) must be equipped with the "Electric panel anti-freeze protection" option and be continuously supplied with electricity. The hydraulic circuit must be filled with an adequate percentage of anti-freeze. In this condition, the minimum external air-temperature which is permitted depends on the chosen model of "Electric panel anti-freeze protection" option, up to a limit value of - C. The functioning mode can also be extended up to external air temperatures of less than - C, but only with a FREE-COOLING configuration which is complete with an adequately sized "Electric panel anti-frost protection" option. In the Standard unit (not the FREE-COOLING configuration) with an empty hydraulic circuit, which has no electricity supply, correct maintenance (not functioning) is possible up to an external air temperature of -0 C. () Max inlet temperature - unit at full load () Max inlet air temperature - Unit at partial load () Min inlet air temperature - Unit at full load and still fresh air () Min inlet air temperature - Unit at partial load and still fresh air () Min inlet air temperature - unit at partial load and air speed of 0. m/s. () Min inlet air temperature - unit at partial load and air speed of m/s. () Standard unit without low temperature liquid device and external exchanger air intake C () Unit with low temperature liquid device and external exchanger air intake C Fluid with ethylene glycol of 0% 0 Graph informed to size. The detail of each size is shown in tabular date. Ta = external exchanger air intake temperature (dry bulb) To ( C) = internal exchanger water outlet temperature 0 -. Standard unit: (not with Low temperature liquid ). Low temperature liquid unit (with ethylene glycol of 0%). Partial-load unit (automatic capacity control). Full-load unit (automatic air flow modulation) - - - - 0 0 0 Ta ( C) SOUND LEVEL Sound Power Level (db) Sound pressure level Sound pressure level Sound power level 0 00 00 000 000 000 db(a) db(a) 0 0 0 0 0 0 0 0 0 0 The sound levels refer to the unit at full load, in the rated test conditions. The sound pressure level refers to a distance of m from the external surface of the units operating in an open field. Measures, according to ISO regulations, are carried out on a reflecting surface, with respect to the EUROVENT / certification. Data referred to the following conditions: - internal exchanger water = / C - outdoor air temperature C BTE00GB-0

ELFOENERGY LARGE VERSION: PREMIUM ACOUSTIC CONFIGURATION: SOUNDPROOFING COMPRESSOR (SC) COOLING PERFORMANCE SIZE 0 0 0 To (ºC) EXTERNAL EXCHANGER AIR INTAKE TEMPERATURE (ºC) HEAT DROP C 0 0 kwf kwe kwf kwe kwf kwe kwf kwe kwf kwe kwf kwe,,,,,0,,, 0, 0,,,,,,,,,, 0,0,0, 0,,,,,0,,,,0 0,,,,,,,,,,, 0, 0,,,,,,,,,,0,, 0,,0,,,,,,,,,,,0,,0,,,,, 0,,,,,,,,,,,,0 0,,,,,,,,,,,, 0,,,,,,,,,,,,0,,, 0,,,,,,0 0,,,,,,,, 0,,0,,,,0,,,,,,,, 0,,, 0,,,,,,,, 0,,,,,,,,,,,, 0,,,,,,,,,,,,,,, 0,,,,,,, 0,,,,,,,,,,,, 0,,,,0,,, 0,,,,,0,0,,,,,,,,,,,,,,,,,,0,,,,,,,,,,,,,,, 0,0,,,,,0, 0,,,0,, 0, 0,,,,,,,,0,,,0 0,,, 0,,,,,, 0,,,,0,,,, 0,,0,,,,0,,,,,,,,0,0,,,,,,, 0,,,,,,,,,,,,0,,,,,,, 0,,,0,,,,0,,,,, 0,,,,,,,, 0,,,, 0,,0,,,,,, 0,,0,,0,,,, 0,,,,,, 0,,,0,,,,,,,,, 0,,,,,,,,,,,,,,,0,,,,0,,,,,,,,,,,,,,,,0,,,0,, 0,,,,,,,,,, 0,,,,,, 0,,,,,, 0,,,,,, 0,,,,,,,,,0,,, 0,,0,,,,,0,,,0,,,,,,,,,,,, 0,,,,,,,,,0,,,,,,,, kwf = Cooling capacity in kw kwe = Compressor power input in kw To = Internal exchanger water outlet temperature in C BTE00GB-0

P [kpa] ELFOENERGY LARGE VERSION: PREMIUM ACOUSTIC CONFIGURATION: SOUNDPROOFING COMPRESSOR (SC) COOLING PERFORMANCE SIZE 0 0 To (ºC) EXTERNAL EXCHANGER AIR INTAKE TEMPERATURE (ºC) HEAT DROP C 0 0 kwf kwe kwf kwe kwf kwe kwf kwe kwf kwe kwf kwe,,,,,,,,,0,,,, 0,,,, 0,,,,,,, 0,0 0,,0,, 0,,,,,,,,0,0 00,,,,,0,,,,,,0, 0,,,,,,,,, 0,,,0,, 0,0,,,,,, 0,,, 0,,,,,,,,,, 0,, 0,,0,,,,,,,,,,,, 0,,,,,,,,,0,,,, 0, 0,,,,0,,,,,,,,0 0,, 0,, 0,0,, 0,,,0,,,,,, 0,, kwf = Cooling capacity in kw kwe = Compressor power input in kw To = Internal exchanger water outlet temperature in C INTERNAL EXCHANGER PRESSURE DROP 0 0 0 0 0 0 0 0 0 0 THE AIR SIDE PRESSURE DROPS ARE RELATIVE TO THE MEDIUM AIR TEMPERATURE OF C Q = AIR FLOW [l/s] DP = PRESSURE DROP [kpa] 0 0 THE WATER FLOW RATE CAN BE CALCULATED WITH THE FOLLOWING FORMULA: 0 Q [l/s] = kwf / (, x DT) 0 kwf = COOLING CAPACITY [kw] DT = TEMPERATURE DIFFERENCE BETWEEN WATER INLET / OUTLET 0 Q [l/s] To the internal exchanger pressure drops must be added the pressure drops of the steel mesh mechanical filter that must be placed on the water input line. It is a device compulsory for the correct unit operation, and it is available as Clivet option (see the HYDRONIC GROUP ACCESSORIES). If the mechanical filter is selected and installed by the Customer, it is forbidden the use of filters with the mesh pitch higher than, mm, because they can cause a bad unit operation and also its serious damaging. ADMISSIBLE WATER FLOW RATE Min. (Qmin) and max. (Qmax) water flow-rates admissible for a correct unit operation. 0 0 0 0 0 Qmin [l/s],,,,,,,,, Qmax [l/s],,,,0,,,,, BTE00GB-0

ELFOENERGY LARGE VERSION: PREMIUM ACOUSTIC CONFIGURATION : EXTREMELY LOW NOISE (EN) ELFOEnergy LARGE GENERAL TECHNICAL SPECIFICATIONS (SERIES WSAT-XEE) SIZE 0 0 0 0 0 COOLING Cooling capacity kw,, Compressor power input kw 0, 0,,,, 0,,, Total power input kw,,,,,,,, Heating capacity total recovery kw 0 Heating capacity partial recovery kw 0 EER,,,,,,,,, ESEER,,,,,0,0,,, COMPRESSOR Type of compressors Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll N. of Compressors Nr Nominal capacity HP 0 0 0 0 0 Standard capacity steps Nr Oil charge l Refrigerant circuits Nr INTERNAL EXCHANGER Type of internal exchanger PHE PHE PHE PHE PHE PHE PHE PHE PHE Water flow rate (Internal Exchanger) l/s,,,,,,, Internal exchanger pressure drop kpa Water content l EXTERNAL SECTION FANS Type of fans AX AX AX AX AX AX AX AX AX Number of fans Nr Standard air flow l/s CONNECTION Water fittings " / " / " / " / " / " / " / " / " / POWER SUPPLY Standard power supply 00/~/0 00/~/0 00/~/0 00/~/0 00/~/0 00/~/0 00/~/0 00/~/0 00/~/0 DIMENSION Length mm 0 0 0 Depth mm Height mm STANDARD UNIT WEIGHTS Shipping weight kg Operating weight kg 0 () data referred to the following conditions : - internal exchanger water = / C - external exchanger air intake C () According to EUROVENT the Total Power Input does not consider the pump share, required to overcome the pressure drop for the solution circulation inside the exchangers. () Option. recovery exchanger water = 0 / C () PHE = plates () AX = axial-flow fan ELECTRICAL DATA ELFOEnergy LARGE (SERIES WSAT-XEE) SIZE 0 0 0 0 0 F.L.A. - FULL LOAD CURRENT AT MAX ADMISSIBLE CONDITIONS F.L.A. - Total A, 0, 0,,,,,, F.L.I. FULL LOAD POWER INPUT AT MAX ADMISSIBLE CONDITION F.L.I. - Total kw,,,,, 0,,, 0, M.I.C. MAXIMUM INRUSH CURRENT M.I.C. - Value A,,,,, 0,, 0, Voltage unbalance: max % Power supply: 00//0 Hz +/-% Electrical data refer to standard units; according to the installed accessories, the data can suffer light variations. BTE00GB-0 0

To ( C) SIZE ELFOENERGY LARGE VERSION: PREMIUM ACOUSTIC CONFIGURATION : EXTREMELY LOW NOISE (EN) OPERATING LIMITS (COOLING) SIZE 0 0 0 0 0 EXTERNAL EXCHANGER Max air intake temperature C 0 0 0 0 Max air intake temperature C Max air intake temperature C 0 0 0 0 0 0 0 0 0 Min. air intake temperature C - - - - - - - - - Min. air intake temperature C - - - - - - - - - Min. air intake temperature C - - - - - - - - - Min. air intake temperature C INTERNAL EXCHANGER Max water inlet temperature C Min. water outlet temperature C Min. water outlet temperature C - - - - - - - - - Data referred to the following conditions : - internal exchanger water = / C - external exchanger air C - still air Warning: the still air condition is meant as absence of air flow to the unit. Any wind condition can let air pass through the condenser coil thus worsening the operating limits of the unit. In case of predominant winds, windbreak barriers are necessary. Note. For correct maintenance (not functioning) with external air temperatures at less than - C, the Standard unit (not the FREE-COOLING configuration) must be equipped with the "Electric panel anti-freeze protection" option and be continuously supplied with electricity. The hydraulic circuit must be filled with an adequate percentage of anti-freeze. In this condition, the minimum external air-temperature which is permitted depends on the chosen model of "Electric panel anti-freeze protection" option, up to a limit value of - C. The functioning mode can also be extended up to external air temperatures of less than - C, but only with a FREE-COOLING configuration which is complete with an adequately sized "Electric panel anti-frost protection" option. In the Standard unit (not the FREE-COOLING configuration) with an empty hydraulic circuit, which has no electricity supply, correct maintenance (not functioning) is possible up to an external air temperature of -0 C. () Max inlet temperature - unit at full load () Max inlet air temperature - Unit at partial load () Min inlet air temperature - Unit at full load and still fresh air () Min inlet air temperature - Unit at partial load and still fresh air () Min inlet air temperature - unit at partial load and air speed of 0. m/s. () Min inlet air temperature - unit at partial load and air speed of m/s. () Standard unit without low temperature liquid device and external exchanger air intake C () Unit with low temperature liquid device and external exchanger air intake C Fluid with ethylene glycol of 0% 0 0 - Graph informed to size. The detail of each size is shown in tabular date. Ta = external exchanger air intake temperature (dry bulb) To ( C) = internal exchanger water outlet temperature. Standard unit: (not with Low temperature liquid ). Low temperature liquid unit (with ethylene glycol of 0%). Partial-load unit (automatic capacity control). Full-load unit (automatic air flow modulation) - - - - 0 0 0 Ta ( C) SOUND LEVEL Sound Power Level (db) Sound pressure level Sound pressure level Sound power level 0 00 00 000 000 000 db(a) db(a) 0 0 0 0 0 0 0 0 0 0 0 The sound levels refer to the unit at full load, in the rated test conditions. The sound pressure level refers to a distance of m from the external surface of the units operating in an open field. Measures, according to ISO regulations, are carried out on a reflecting surface, with respect to the EUROVENT / certification. Data referred to the following conditions: - internal exchanger water = / C - outdoor air temperature C The sound levels indicated sideways are valid only for the operating range of the Extremely low noise EN configuration; with fresh air temperatures higher and in any case into the operating range of the Compressor soundproofing SC configuration, consider the sound levels of the Compressor soundproofing configuration. BTE00GB-0

ELFOENERGY LARGE VERSION: PREMIUM ACOUSTIC CONFIGURATION : EXTREMELY LOW NOISE (EN) COOLING PERFORMANCE SIZE 0 0 0 To (ºC) EXTERNAL EXCHANGER AIR INTAKE TEMPERATURE (ºC) HEAT DROP C 0 0 kwf kwe kwf kwe kwf kwe kwf kwe kwf kwe kwf kwe,,,,,,,,,,0,0,,,,0,,,,,,,,,,,,,,,, 0,0,0,,,,,,, 0,0,, 0,,,,, 0,,,,,,, 0,,,,,,,0,,,,, 0,,,0,,,,,,0,, 0,,,0,,,,,,,,,,0,,,,,, 0,0,,,,,,,,,,, 0,,,0,,,,,,,,, 0,,,,, 0,,0,,,,,,0,,,,,,,,,,,,,,0,,,0,,,,,,,,,,,,, 0,,0,,,,,,,,, 0,,,,,,,,,,,, 0,,,,,0,,,0,,,, 0,,0,,0,,,,,,0,,0,,,,,,,0,,,0,,,,,0,,,, 0,,, 0,,0,,,,,,,,, 0, 0,,,,,,,,,,,,,0,,,,,,,, 0, 0,,,,,,,0,,0 0,,,,0 0,,,,,,0,,,,,,,,,,,0,,,0,,,,,, 0,,,,, 0,,,,,,0,,,,,,,,,,,0,,,,,,,,,, 0,,,,,,,,,,, 0,,,,,,,,, 0,,,,,,,, 0,,,, 0,,,0,,,,,,,,,,,,,,0,, 0,,,,,,,,,,,0, 0,,,0,,,,0,,,,,0,,, 0,,,,,,,,,,,,,,,,,,,,,,,,,,,,, 0,,,,0,0,,,,,,, 0,,,,,, 0,,,,,0,,,,,,, 0,,0,,,,,,,0,,, 0,,0,,0,,,,0,,,,,0,,,,0 kwf = Cooling capacity in kw kwe = Compressor power input in kw To = Internal exchanger water outlet temperature in C BTE00GB-0

P [kpa] ELFOENERGY LARGE VERSION: PREMIUM ACOUSTIC CONFIGURATION : EXTREMELY LOW NOISE (EN) COOLING PERFORMANCE SIZE 0 0 To (ºC) EXTERNAL EXCHANGER AIR INTAKE TEMPERATURE (ºC) HEAT DROP C 0 0 kwf kwe kwf kwe kwf kwe kwf kwe kwf kwe kwf kwe,,,,, 0,,,,,,0,,,,,, 0,,,,,, 0,0,,0,,,,,,,0,, 0,,0,,,,,,,,,0,, 0,,, 0,,,,,0,,,, 0,,, 0,,,0,0,, 0,,,0 0,,,,0,,,,,,,0,0,,0 0,,0 00, 0,,0,,,0, 0,,, 0,, 0,,,,0,,,,0,,,,,, 0,,,,,,,,0, 0,,, 0,, 0,0,,,,,, 0,,,,, 0,,,, kwf = Cooling capacity in kw kwe = Compressor power input in kw To = Internal exchanger water outlet temperature in C INTERNAL EXCHANGER PRESSURE DROP 0 0 0 0 0 0 0 0 0 0 THE AIR SIDE PRESSURE DROPS ARE RELATIVE TO THE MEDIUM AIR TEMPERATURE OF C Q = AIR FLOW [l/s] DP = PRESSURE DROP [kpa] 0 0 THE WATER FLOW RATE CAN BE CALCULATED WITH THE FOLLOWING FORMULA: 0 Q [l/s] = kwf / (, x DT) 0 kwf = COOLING CAPACITY [kw] DT = TEMPERATURE DIFFERENCE BETWEEN WATER INLET / OUTLET 0 Q [l/s] To the internal exchanger pressure drops must be added the pressure drops of the steel mesh mechanical filter that must be placed on the water input line. It is a device compulsory for the correct unit operation, and it is available as Clivet option (see the HYDRONIC GROUP ACCESSORIES). If the mechanical filter is selected and installed by the Customer, it is forbidden the use of filters with the mesh pitch higher than, mm, because they can cause a bad unit operation and also its serious damaging. ADMISSIBLE WATER FLOW RATE Min. (Qmin) and max. (Qmax) water flow-rates admissible for a correct unit operation. 0 0 0 0 0 Qmin [l/s],,,,,,,,, Qmax [l/s],,,,0,,,,, BTE00GB-0

Δ P [kpa] ELFOENERGY LARGE CONFIGURATIONS Consult the appropriate table, shown in the final section, to verify the compatibility between the different options. B - WATER LOW TEMPERATURE Configuration also known as "Brine". Enables a non-freezable solution to be cooled (for instance, water and ethylene glycol in appropriate quantities) up to a temperature of between + C and C. Includes: - Appropriate exchangers, complete with thick closed-cell insulation; - Electronic-type expansion valve, functional calibration and safety devices adapted to the particulars of use. In the selection phase, it is necessary to indicate the type of function required, and the unit will be optimised with: - Unit with single working set-point (only at low temperature) - Unit with double working set-point. The unit in this configuration have a different operation field, indicated on the previous pages. In the low temperature operation, some partialisation degrees could be not available. For more information, contact our Sales Department. D - PARTIAL ENERGY RECOVERY Configuration which allows hot water production free-of-charge during the cooling function, thanks to the recovery of part of the condensation heat which would otherwise be disposed of into the external heat source. This configuration is also known as "desuperheating coil". It is made up of brazed-plate exchanger in AISI stainless steel which is ideal for recovering around a quarter of the heating capacity of the unit (equal to the sum of the cooling capacity and the absorbed power input of the compressors). EEV D T T RW in 0 C RW out C AE C The partial recovery device is considered to be working when it is supplied by the flow of water to be heated. This condition improves the unit performance, since it reduces the condensation temperature: in nominal conditions, the cooling capacity increases indicatively by,% and the absorbed power input from the compressors is reduced by,%. TW out C TW in C When the temperature of the water to be heated is particularly low, it is opportune to insert a flow regulation valve in the hydraulic circuit, to maintain the recovery output temperature at higher than C and thus avoid refrigerant condensation in the partial energy recovery device. D - Partial recovery device. Internal exchanger. Compressors. Recovery exchanger. External exchanger. Electronic expansion valve TW in Chilled water Inlet TW out Chilled water Outlet RW in Recovery water inlet RW out Recovery water outlet AE Outdoor air INTERNAL EXCHANGER PRESSURE DROP - PARTIAL ENERGY RECOVERY 0 0-0 -0 0-0 0 0 0,,,,,, Q WATER FLOW RATE [l/s] DP PRESSURE DROP [kpa] Q [l/s] BTE00GB-0

ELFOENERGY LARGE R - TOTAL ENERGY RECOVERY Configuration which allows hot water production free-of-charge during the cooling function, thanks to the total recovery of the condensation heat which would otherwise be discharge into the external heat source. This solution increases the overall efficiency of the system in all cases in which a high-level of hot water production is requested. It is made up of Stainless steel brazed plate heat exchanger, which is ideal for recovering the entire unit heating capacity (equal to the sum of the cooling capacity and the absorbed power input of the compressors), from the on-of type solenoid valves, the temperature sensors for the hot water circuit supply and return and the relative integrated logic controller with two partialisation steps. La disponibilità di acqua calda è sempre subordinata alla produzione di acqua refrigerata. Si veda il seguente esempio:. Cooling capacity request = 0% / Heat capacity request = 0% Cooling capacity production only.. Cooling capacity request = 0% / Heat capacity request = 0% Cooling capacity production and heat capacity production by recovery.. Cooling capacity request = 0% / Heat capacity request = 0% Cooling capacity production and heat capacity production by recovery, equals 0% of the requested heat capacity. To avoid constant switching in the cooling circuit should be added to a adequate capacity storage tank in the hot water circuit of the system. If the hot water circulation is not present on the heat recovery exchanger, the maximum inlet air temperature decreases of about C compared to units without 'Total Energy Recovery'. TOTAL ENERGY RECOVERY OPERATING When hot water is required, the condensing coil is turned off. The condensation takes place entirely in the recovery circuit. TOTAL ENERGY RECOVERY NOT OPERATING When the set-point recovery is fulfilled, the coil is reactivated. In this condition the total recovery circuit operates as a partial recovery (desuperheater). T RW in 0 C AE C T RW in C AE C EEV R T RW out C EEV R T RW out C TW out C TW in C TW out C TW in C R - Total recovery device Internal exchanger Compressors Recovery exchanger Total recovery enabling valve External exchanger enabling valve External exchanger Electronic expansion valve T Temperature probe TW in Chilled water inlet TW out Chilled water outlet RW Recovery water inlet RW out Recovery water outlet AE Outdoor air INTERNAL EXCHANGER PRESSURE DROP - TOTAL RECOVERY ENERGY ΔP [kpa] 0 0 0 0 0 0 0 0 0 Q [l/s] Q WATER FLOW RATE [l/s] DP PRESSURE DROP [kpa] BTE00GB-0

ELFOENERGY LARGE FCD - DIRECT FREE-COOLING Configuration which enables great savings on the management costs of the system in applications which require chilled water even during cold seasons like, for instance, industrial processes, data centres, telecommunications, technological applications and trade centres. When the external air temperature is less than the temperature of the return water in the system, the FREE-COOLING system recovers coolness from outdoor and reduces the compressor working up to their being withdrawn completely. The higher the temperature of the chilled water in the system (e.g. - C instead of - C), the greater the field of application of the FREE-COOLING system and, therefore, the energy saving. USING UNFREEZABLE SOLUTIONS The FREE-COOLING configuration is particularly indicated in buildings where, at least at certain times of the year, the external air temperature also reaches very low values. For this reason, the liquid must be protected from the risk of freezing, typically by adding an appropriate anti-freeze substance such as ethylene glycol. The percentage of glycol in the solution depends on the minimum temperature value foreseen in the installation area, and in any case, remains within the main parameters of the system design. TECHNICAL DESCRIPTION In comparison with standard units, Clivet units in the direct FREE-COOLING configuration also include: three-way switching valve with on/off regulation Finned water-air COIL exchanger (FREE-COOLING coil) additional outdoor air temperature sensor and control logic dedicated flush hydraulic connections. MANAGEMENT LOGIC There are three main function modes, which can be differentiated in essence by the position of the three-way switching valve and by the number of active compressors. T AE C (A) SUMMER SEASON In the summer, with external air temperatures greater than the return temperature of the system liquid, the three-way valve is switched in such a way as to exclude the FREE-COOLING coils. The cooling of the liquid is referred to the direct expansion circuit, via the workings of the compressors as in a traditional chiller. (B) INTERMEDIATE SEASON During the intermediate season, or rather when the external air temperature is a little less than the temperature of the return water in the system, when the system senses that the external air temperature conditions are favourable: it switches the position of the three-way valve forcing the solution to transit through the FREE-COOLING coils before reaching the evaporator; it puts the fans to their maximum speed to exploit as much as possible the solution cooling using the outdoor air ; it undertakes the initial cooling of the solution in a "natural and free" way; it supplies any missing capacity through the chiller cycle, using the compressors functioning partially (the absorbed power input is proportional to the level of partialisation). In case of an increase in the external air temperature, the microprocessor automatically converts the unit functioning to the summer setting, guaranteeing the conditions requested by the user at all times. EEV TW out C EEV TW in C T A AE C (C) WINTER SEASON During the winter season, with the temperature of the external air lower than the temperature of the return water in the system, the system senses that conditions are favourable for the FREE-COOLING function: the three-way valve is switched as in the previous case, forcing the solution to transit through the FREE-COOLING coils before reaching the evaporator; the external air temperature brings the solution to the FREE-COOLING coil output already at the temperature requested by the user; the microprocessor management totally deactivates all the compressors supplying all the requested cooling capacity AT NO COST, in contrast to traditional chillers. The difference between the outdoor air temperature and that requested by the user can also be such as to lower the solution temperature at the FREE-COOLING coil output to below the set-point requested for this use. This is a condition which does not compromise unit safety thanks to the presence of anti-freeze in the solution. The microprocessor modulates the fan speed until their withdrawal. If, with all the fans switched off, the temperature continues to go down, the three-way valve automatically positions itself in the summer setting, thus enabling the set-point to be maintained. TW out C EEV TW out C TW in C TW in C T B AE 0 C C D - Partial recovery device. Internal exchanger. Compressors. Recovery exchanger. External exchanger. Electronic expansion valve TW in Chilled water Inlet TW out RW in RW out AE Chilled water Outlet Recovery water inlet Recovery water outlet Outdoor air BTE00GB-0

DT [ C] ELFOENERGY LARGE UNIT PERFORMANCES IN THE DIRECT FREE-COOLING CONFIGURATION The unit performance in the direct FREE-COOLING configuration also depends on the antifreeze percentage used in the circuit and are shown below in two main operating modes. OPERATING MODE: DEACTIVATED DIRECT FREE-COOLING To consider the standard unit performance at the requested conditions and apply the following correction factors. Percentage weight of ethylene glycol % 0% 0% 0% Cooling power factor 0, 0, 0, 0, Compressor input factor,00,0,00,0 EXAMPLE Determine the performance of the following units : WSAT-XEE FCD 0 SC EXC (EXCELLENCE version, direct FREE-COOLING configuration), with water = / C / 0% glycol / Outdoor air C Reference: WSAT-XEE S 0 SC EXC Cooling capacity =, kw / Electric compressor capacity =, kw Calculation: WSAT-XEE FCD 0 SC EXC (Direct FREE-COOLING) Cooling capacity =, x 0, = 0, kw / Electric compressor capacity =, x,0 =, kw OPERATING MODE: ACTIVATED DIRECT FREE-COOLING Size (SC / EN Version) 0 0 0 0 0 Free-cooling nominal capacity () kw 0 Temperature wih Free-cooling at 0% () C 0, -0, -,0 0,0-0, -,0 -, 0,0 -, () Data referred to the following conditions: - water temperature: C inlet / C outlet - glycol percentage 0% When the outside air temperature increases, the cooling capacity of FREE-COOLING decreases (at the same temperature of water on returning from). If you know the cooling capacity required by the system, you can calculate the maximum outside air temperature from which the cooling capacity is available through FREE-COOLING. Below this temperature, the required power is supplied only by modulation of the air flow fans. 0-0 0-0- --0 0% 0% 0% 0% 0% 0% 0% 0% 0% % FC KEY DT %FC Approach between the system outlet water temperature and the outdoor air FREE-COOLING percentage (compared with the FREE-COOLING nominal capacity) EXAMPLE Determine the performances with outdoor air = + C for the following unit: WSAT-XEE FCD 0 SC EXC, EXCELLENCE version, Direct FREE-COOLING configuration), with water at / C / 0% glycol. Reference: WSAT-XEE FCD 0 SC EXC FREE-COOLING nominal capacity = 0 kw (from table - Water / C / 0% glycol / outdoor air temperature 0 C) Calculation: Approach between the system outlet water temperature and the outdoor air = C - C = C From the graph: FREE-COOLING percentage = % FREE-COOLING capacity at + C of outdoor temperature = 0 x % =, kw BTE00GB-0

ELFOENERGY LARGE HYDRONIC GROUP ACCESSORIES PUS - STANDARD PUMP Option supplied built-in. Centrifugal electro-pump, with AISI type 0 stainless steel body and rotor. Mechanical seal using ceramic, carbon and EPDM elastomer components. Three-phase electric motor with an IP protection. Complete with thermoforming insulating shell, rapid attachments with insulating shells, non-return valve, safety valve, manometers, system load safety pressure switch, stainless steel anti-freeze immersion heaters set on inlet and supply. The different available models can be set apart by the useful prevalence of the system. PUSB - STANDARD PUMP WITH EMERGENCY PUMP Option supplied built-in. Two centrifugal electro-pumps one of which is in stand-by, with AISI type 0 stainless steel body and impeller. Mechanical seal using ceramic, carbon and EPDM elastomer components. Three-phase electric motor with an IP protection. Complete with thermoforming insulating shell, rapid attachments with insulating shells, non-return valve, safety valve, manometers, system load safety pressure switch, stainless steel anti-freeze immersion heaters set on inlet and supply. The built-in microprocessor controller balances the working hours and in case of any breakdown signals the fault and automatically activates the reserve pump. The different available models can be set apart by the useful prevalence of the system The PUS and PUSB options are supplied as standard with a hydraulic connection kit on the system return (to be installed externally to the unit, by the Customer). The kit is made up of: no. cast-iron butterfly shut-off valve, complete with activating handle and mechanical calibration lock no. rapid connection A00 / A00-00 / 00 LITRES STORAGE TANK Option supplied built-in. Stainless steel storage tank complete with double-sheeted coating with closed-cell insulation, stainless steel anti-freeze immersion heater, bleed valve, discharge cock, cast-iron butterfly shut-off valve with rapid attachments and activating handle with mechanical calibration lock at the evaporator output, rapid attachments with insulation shells. The available models have different static pressure. The A00 and A00 options are supplied as standard with the hydraulic connection kit on the system return (to be installed externally to the unit, by the Customer). The kit is made up of: no. cast-iron butterfly intercept valve, complete with activating handles and mechanical calibration lock no. rapid connection STANDARD PUMP / STANDARD PUMP WITH EMERGENCY PUMP STORAGE TANK STANDARD PUMP / WITH EMERGENCY PUMP AND STORAGE TANK TW out C TW in C TW out C TW in C TW out C TW in C A A IFWX IFWX IFWX Internal exchanger Shut-off valve Bleed valve Storage tank with antifreeze heater Drain valve Shut-off valve with rapid connection Steel mesh filter water side Manometer Safety valve ( Bar) Closed couple pumps with high efficiency impellers Non-return valve Safety pressure switch system load (Prevents the operation of the pumps in case of lack of water) TW in Cooling water inlet TW out Cooling water outlet - - - Standard Hydraulic connection Kit The gray area indicates additional optional components. BTE00GB-0

0 0 0 0 0 ΔP [KPa] 0 0 0 0 0 ΔP [KPa] ELFOENERGY LARGE PUS / PUSB PERFORMANCE OPTIONS VERSION: EXCELLENCE 0 0 0 00 0 0 0 0 0 0 0 0 PU PU PU PU PU PU,,,,,,,,, Q [l/s] VERSION: PREMIUM 0 0 0 00 0 0 0 0 0 0 0 0 PU PU PU PU PU PU,,,,,,,,, Q [l/s] Attention: to obtain the values of available head, the heads represented on these charts must be decreased by: Evaporator pressure drop IFVX Accessory - Steel mesh filter water side (if supplied) SINGLE PUMP TECHNICAL FEATURES PUMP NOMINAL CAPACITY [kw] NOMINAL CURRENT [A] PU,, PU,, PU,, PU,, PU,, PU,, BTE00GB-0

P [kpa] ELFOENERGY LARGE A00RPS / A00RPS - 00 / 00 LITRES STORAGE TANK WITH PRIMARY CIRCUIT BUILT-IN Option supplied built-in. Simplifies system design and manufacture. Available only with PUS option - Standard pump or PUSB - Standard pump with emergency pump. This accessory includes components designed for the A00 / A00 option and: Primary circuit, already built and tested on the unit cast-iron butterfly shut-off valve, with rapid connection and activating handle and mechanical calibration lock in evaporator outlet and on the pump suction A00RPS / A00RPS options are available only with Low head pump option. TW out C TW in C A Internal exchanger Shut-off valve Bleed valve Storage tank with antifreeze heater Drain valve Shut-off valve with rapid connection Steel mesh filter water side Manometer Safety valve ( Bar) Closed couple pumps with high efficiency impellers Non-return valve Safety pressure switch system load (Prevents the operation of the pumps in case of lack of water) TW in Cooling water inlet TW out Cooling water outlet The gray area indicates additional optional components. IFWX IFWX - STEEL MESH FILTER WATER SIDE The device prevents fouling of the exchanger by any impurities in the hydraulic circuit. The mechanical filter mesh stainless steel should be placed on the water inlet. It is easily removed for periodic maintenance and cleaning. Also includes: cast-iron butterfly shut-off valve, with rapid connection and activating handle and mechanical calibration lock; rapid connections with insulating protection. STEEL MESH FILTER PRESSURE DROP 0 0 STEEL MESH FILTER CHARACTERISTICS SIZE 0 Diameter / Filtering degree, mm 0 Q = WATER FLOW [l/s] Q [l/s] DP = PRESSURE DROP WATER SIDE[kPa] Pressure drop with clean filter Installation by the User, outside the unit Check the presence of the necessary hydraulic shut off valve on the system, to the periodic maintenance Accessories supplied separately BTE00GB-0 0

ELFOENERGY LARGE ABU - FLUSH HYDRAULIC CONNECTIONS Option which simplifies the hydraulic connections which otherwise occur within the unit (by the Customer). Includes from internal piping to the external unit panel, two rapid flush connections, two "welding" pipes for connecting to the system by the Customer. The accessory is supplied built-in. A - STANDARD UNIT B - UNIT WITH ABU OPTION IMPORTANT! The flush hydraulic connections are supplied as a standard in the unit complete with the following options: Direct FREE-COOLING configuration Standard pump / Standard emergency pump Storage tank Storage tank with a primary circuit built-in HYDROPACK Scheme, not in scale GENERAL NOTE It is also opportune to provide for the following system components, which are not included in the Clivet supply. Shut-off valve, where it is not already provided for in the Clivet supply. Support devices for the piping and anti-vibration flexible joints. Expansion vessel (example for closed-circuit system) Supply control thermometer Additional vent and discharge valves where necessary BTE00GB-0

ELFOENERGY LARGE HYDROPACK PM - HYDROPACK WITH TWO PUMPS Option supplied built-in. Pumping station made up of two parallel electro-pumps, with modular self-adapting activation logic. Enables an automatic reduction in liquid flow in critical conditions, avoiding blocks due to overloading and consequential interventions by specialised technical personnel. Centrifugal electro-pump, with AISI type 0 stainless steel body and impeller. Mechanical seal using ceramic, carbon and EPDM elastomer components. Three-phase electric motor with an IP protection. Three-phase electric motor with an IP protection grade. Complete with thermoforming insulating shell, rapid connections with insulating shells, non-return valve, safety valve, manometers, system load safety pressure switch, stainless steel anti-freeze immersion inlet and supply resistances. The different available models can be set apart by the useful prevalence of the system. The PM option is supplied as standard with the hydraulic connection kit on the system return (to be installed externally to the unit, by the Customer). The kit is made up of: no. cast-iron butterfly intercept valve, complete with activating handles and mechanical calibration lock no. rapid connection The PM option is supplied with a kit made up of blind rapid connections, for the removal of a pump in case of maintenance. The PM option is: compatible with the A00 / A00 option - 00 / 00 litre storage tank not compatible with the A00RPS / A00RPS option - 00 / 00 litres storage tank with a primary circuit built-in. HYDROPACK HYDROPACK WITH STORAGE TANK TW out C TW in C TW out C TW in C IFWX IFWX Internal exchanger Compressors Recovery exchanger Total recovery enabling valve External exchanger enabling valve External exchanger Electronic expansion valve T Temperature probe TW in Chilled water inlet TW out Chilled water outlet RW Recovery water inlet RW out Recovery water out - - - Standard Hydraulic connection Kit The gray area indicates additional optional components. BTE00GB-0

0 0 0 0 0 ΔP [KPa] 0 0 0 0 0 ΔP [KPa] ELFOENERGY LARGE PERFORMANCES OF THE PM OPTION (HYDROPACK) VERSION: EXCELLENCE 0 0 0 00 0 0 0 0 0 0 0 0 x PU x PU x PU x PU x PU,,,,,,,,,,, Q [l/s] VERSION: PREMIUM 0 0 0 00 0 0 0 0 0 x PU x PU x PU 0 0 x PU x PU 0,,,,,,,,,,, Q [l/s] Attention: to obtain the values of available head, the heads represented on these charts must be decreased by: Evaporator pressure drop IFVX Accessory - Steel mesh filter water side (if supplied) SINGLE PUMP TECHNICAL CHARACTERISTICS PUMP NOMINAL CAPACITY [kw] NOMINAL CURRENT [A] PU x, x, PU x, x, PU x, x, PU x, x, PU x, x, BTE00GB-0

ELFOENERGY LARGE ACCESSORIES PGFC - FINNED COIL PROTECTION GRILL This accessory is used to protect the external coil from the accidental contact with external things or people. Ideal for installation in places where is possible the passage of people such as parking, terraces, etc. The accessory is supplied built-in. PGCCH - ANTI-HAIL PROTECTION GRILLES This accessory is used to protect the external coil from hail. The hail can deform the fins of the Exchange worsting heat exchange with air. The accessory is supplied built-in. CCCA - COPPER / ALUMINIUM CONDENSER COIL WITH ACRYLIC LINING Batteries with copper tubes and aluminium fins with acrylic paint. They can be used in the presence of saline concentrations in the air and other weathering agents moderately aggressive. Option is not suitable for application in sulphureous ambient. CCCA - COPPER / ALUMINIUM CONDENSER COIL WITH FIN GUARD (SILVER) TREATMENT Treatment that offers an optimum heat exchange and guaranteed over time and protects against corrosion finned heat exchangers. They can be used in the presence of saline concentrations in the air and other aggressive chemical agents, keeping the performance of the exchanger constant over time. CCCC - COPPER / COPPER CONDENSER COIL Exchange with copper tubes, copper fins and brass shell. They can be used in the presence of saline concentrations in the air and other weathering agents moderately aggressive. Option is not suitable for application in sulphureous ambient. AMMX - SPRING ANTIVIBRATION MOUNTS The spring anti-vibration devices are fastened in housings on the longitudinal members. They reduce the vibrations caused by the machine, reducing the noises transmitted by the support structures. Accessory is supplied separately BTE00GB-0

ELFOENERGY LARGE FANQE - ELECTRICAL PANEL VENTILATION This option is necessary for very hot climates, where the external temperature can be between +0 C and +0 C. It is made up of a forced ventilation system, activated by a thermostat, which provides for the correct usage temperature to be maintained by the components inside the electrical panel. The option includes a thermostat which activates forced ventilation when necessary. The device is installed and tested built-in. This accessory functions at all times even when the unit is switched off as long as the electricity supply is maintained and the unit is not isolated. In order to guarantee that the correct unit operation, the temperature inside the unit must not exceed 0 C. Therefore, during storage or when the unit is already installed but not powered, it is necessary to avoid exceeding the above-indicated temperature. When the unit has been installed, the protection and safety devices are only active with the power supply switched on and the unit not isolated. RE-0 / RE- / RE-0 / RE- / RE- - PROTEZIONE ANTIGELO QUADRO ELETTRICO This option is necessary for very cold climates, where the external temperature can be between - C and - C. It includes thermostat self-regulating heaters which are able to protect the electric panel from condensation and frost, guaranteeing its correct operation. The selection of devices is carried out based on the minimum temperatures reached at the unit installation site. The device is installed and tested built-in. This accessory is necessary for the correct unit operation in the FCD (FREE-COOLING) configuration with external temperatures below C. Furthermore, it is necessary for the units to be maintained correctly in all the remaining configurations (not functioning). This addiction element stay always switch on also when the unit is switch off as long as to keep the supply power on. This accessory does not lead to substantial variations in the electrical data of the unit declared in the section Electrical Data. PM - PHASE MONITOR The phase monitor makes it possible to check the correct connection of the phases and their imbalance in units powered with a tri-phase system. If the connection of the phases is not correct, or the threshold of phase imbalance is exceeded, or the voltage is too high or too low for a certain amount of time, the monitor acts on the control circuit and orders the unit to be shut down. As soon as nominal line conditions are restored, the unit is automatically reset. As soon as nominal line conditions are restored, the unit reset is manual. The device is installed and tested built-in. PFCP - POWER FACTOR CORRECTION CAPACITORS The component is necessary to lower the phase difference between current and voltage in the electromagnetic components of the machine, such as asynchronous motors. By re-phasing it is possible to reduce the intensity of the line current by reducing a part of the power of the mains (reactive power). This often leads to an economic benefit which the energy provider grants to the final user. The component makes it possible to bring the cosfi power factor to values which on average are greater than 0.. The device is installed and tested built-in. SFSTR - BREAKAWAY CURRENT REDUCING DEVICE Option also known as 'Soft starter'. Electronic device that automatically and gradually starts the compressors reducing the start-up current of about 0% in comparison with the nominal value. It follows that the electrical power and its protective devices can be sized with lower parameters, so with a lower cost of initial investment. I Nominal operating point The device is installed and tested built-in. RPM - - - CURRENT ABSORBED WITHOUT SFSTR OPTION CURRENT ABSORBED WITH SFSTR OPTION ELFOEnergy LARGE ELECTRICAL DATA (SERIES WSAT-XEE) WITH SFSTR OPTION SIZE 0 0 0 0 0 M.I.C. MAXIMUM INRUSH CURRENT M.I.C. - Value (EXCELLENCE VERSION) A 0 M.I.C. - Value (PREMIUM VERSION) A 0 0 BTE00GB-0

ELFOENERGY LARGE MHP - HIGH AND LOW PRESSURE GAUGESMANOMETRI Although the standard unit permit already to show the digital parameters of pressure of the refrigeration circuit, this option allow the analogic measures of the refrigerant pressures on suction and compression, giving a most easy way to check the work parameters from specialists in the field. The two liquid pressure gauges and corresponding pressure sockets are installed on the machine in an easily accessible location. The device is installed and tested built-in. SDV - SHUT-OFF VALVE ON COMPRESSOR SUCTION AND DISCHARGE This option integrates the shut-off valve, supplied as standard. The presence of the shut-off valve also on the inlet enables the compressors to be isolated and substituted without discharging the refrigerant from the entire chiller circuit. Extraordinary maintenance activities are thus eased. The device is installed and tested built-in. Compressors Shut-off valve Safety valve SDV option CREFP - DEVICE FOR FAN CONSUMPTION REDUCTION OF THE EXTERNAL SECTION WITH VARIABLE SPEED (PHASE-CUTTING) (ONLY EXCELLENCE VERSION) External axial fan option. This device is installed as an alternative to the ECOBREEZE that is standard on the EXCELLENCE version. It provides the three-phase electric motor with external rotor and built-in thermal protection, running IP. It is equipped with variable speed control. The device is installed and tested built-in. KRIX - KIT FOR REMOTE MICROPROCESSOR REMOTE CONTROL INTERFACE This accessory permits to be install keyboard in a remote position. It includes the compartment and the power transformer. To be connected during commissioning of the unit at a maximum distance of 00 m. Unit connection. Shielded cable. Power input x 0. mm MAX 00 m 0//0 The compartment must be installed on a wall using appropriate anchors. It can also be mounted on wall box universal 0 (installation by the costumer) The transformer is designed for DIN rail. It must be powered at 0//0 and electrically connected to the multifunction keypad compartment (installation by the costumer) Separately provided accessory BTE00GB-0

ELFOENERGY LARGE CFSC - FREE CONTACTS FOR COMPRESSOR STATE Option to display the compressor operating status from the remote location. The contacts are available in a special terminal block. CLSCLR - FREE CONTACTS FOR COMPRESSOR STATE AND FOR OPERATION IN LOCAL/REMOTE MODE - + MAX V A Option to display the compressor operating status from the remote location. The contacts are available in a special terminal block. The three-position selector allows the following actions: Sequential unit switching off that allows its next correct restarting Enabling to the unit starting from the built-in multifunction keypad. Enabling to the unit starting via serial port from remote supervisor. SELECTOR POSITION UNIT STATUS 0 OFF LOCAL ON FROM SERIAL - + MAX V A 0 SPC - SPC - SET POINT COMPENSATION WITH 0- V SIGNAL The device allows variation of the set-point pre-set by an external signal of type 0 V. Set-Point [ C] 0 Input [V] SPC - SET POINT COMPENSATION WITH -0 ma The device allows variation of the set-point pre-set by an external signal of type 0 ma. Set-Point [ C] 0 Input [ma] SPC - SET POINT COMPENSATION WITH OUTSIDE TEMPERATURE PROBE The device allows the automatic adjustment of the setpoint pre-set depending on outside air temperature. It provides the sliding temperature of the liquid, that is variable depending on external conditions, for the benefit of saving energy of the system. Set-Point [ C] The device is installed and tested built-in. 0 0 Air Temperature (dry bulb) [ C] BTE00GB-0

ELFOENERGY LARGE SPC - SET POINT COMPENSATION ACCORDING TO THE OUTSIDE ENTHALPY The device allows the automatic adjustment of the unit set-point according to the external enthalpy. It provides the sliding temperature of the liquid, that is variable depending on external conditions, for the benefit of saving energy of the system. The device is installed and tested built-in. CMSC - BACnet SERIAL CONVERTER KIT It allows serial connection of supervision systems, using BACnet or SNMPv.0 as the communication protocol. It allows access to the complete list of operating variables, controls and alarms. The device has the following communication ports: serial ports configurable as RS or RS protocols available for MODBUS and BACnet MSTP; RJ Ethernet port for BACnet IP, SNMPv, TCP / IP. ETHERNET The device configuration is done through the integrated Web Server Linux can be done from a PC connected to the network. The device is installed and tested built-in. The configuration and management of the BACnet network are by the Customer CMSC - LonWorks SERIAL CONVERTER KIT It allows serial connection of supervision systems, using LonWorks as the communication protocol. It allows access to a list of operating variables, control and alarms compliant with the Echelon standard. The device is installed and tested built-in. The configuration and management of the LonWorks network are by the Customer The LonWorks technology uses LonTalk protocol for the communication between network nodes. Contact your service provider for more information BTE00GB-0