Domestic AC Fans 230V Installation and Operating Guide. eco. 230V AC Base Models: icon eco icon icon icon

Similar documents
nergybulbs.co.uk Domestic AC Fans 230V Installation and Operating Guide Quick Order Hotline or

9 inch and 12 inch Axial Fans Models MV230P, MV230AR and MV300AR Instructions for installation, maintenance and safe use.

Installation & Operating Instructions

IF IN DOUBT, INSTALLATION SHOULD BE MADE BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH CURRENT WIRING REGULATIONS.

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

Lo-Carbon Quadra Centrifugal Fan

Lo-Carbon Quadra SELV

Installation & Operating Instructions

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS.

Centrif Duo & Centrif Duo Plus

MODEL: BV400 Part No:

Lo-Carbon SELV Tempra

"Microbox" DC Models MBOX 125/2DC MBOX 125/2DC204

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

Vent-Axia Svara Multifunctional app controlled fan. Important Information 2 Installation and Wiring Instructions 3-11 Accessories 12 Pin Code 12

Lucci Designer Hi Flow Exhaust Fan

VA100 SELV 12 RANGE. Installation and Wiring Instructions IPX7

Flue Dilution Fans. Specialists in Air Movement Technology. IMPROVED GBDF MK5 Now includes a Pressure Safety Switch and easier Electrical Connections

Lo-Carbon T-series Window & Roof Models

T-SERIES. Wall & Panel Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz

MODEL: DV72 R & L. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual

T-SERIES. Window & Roof Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz

Silhouette Installation and Wiring Instructions

Lo-Carbon Quadra Centrifugal Fan

BLOW DRY & GO HAIR KIT

Lo-Carbon SOLO Plus SELV Centrifugal Bathroom/Toilet Fan

WHHR Midi & Midi Lite

airooncentre.co.uk irconcentre.co.uk Xpelair Low Energy Wall/Window Fan Range GX6 EC2 GXC6 EC2 Quick Order Hotline or

YOUR SAFETY & INSTRUCTION MANUAL PLEASE READ CAREFULLY HAIR CARE GIFT SET MODEL C85003

"Microbox" Continuous Mechanical Extract Ventilation Units. Installation, Operating and Maintenance Instructions

"WHHR125DC" Whole House Heat Recovery Unit with Low Energy DC Motor. Installation, Operating and Maintenance Instructions domestic and commercial use

Lo-Carbon MULTIVENT MVDC-MS & MVDC-MS H VENTILATION SYSTEMS V~50Hz. Installation and Wiring Instructions IP22. Stock Ref.

Glass Chimney Hood. Installation & User Instructions Please keep for future reference

INDEX WARNINGS AND RECOMMENDATIONS 2 COMPLIANCE DECLARATIONS 3 RANGE AND SIZES 3 ELECTRICITY SUPPLY 3 INSTALLATION 4 INSTRUCTIONS FOR UNINSTALLING

200W Frostwatch Radiant Heater Operation Manual

EXTRACTOR HOOD. Please read all the instructions carefully before starting the installation. 230 / 240V 50Hz

EKF. EC kitchen extract fan range. Installation and Wiring Instructions. Stock Ref. N EKF355E1 EKF400E1 EKF450E1 EKF450E3 EKF500E3 EKF560E3

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

ELIX 1003 IPX4. Energy Efficient Centrifugal Fan with EC Motor Installation and Operating Instructions

Model: Kair Whole House Ventilator Model Number: KHRVWH2000

CoCo LoCo BLOW & GO NUTS DRYER. LSHD24 Instruction Manual

INSTALLATION USE AND MAINTENANCE MANUAL. ATC Evolution ATC EVOLUTION. Class I - IP55 INFRARED HEATER ATC ELECTRICAL & MECHANICAL

PH1000T PH1500T PH2000T

Whole Room Dryer WRD, WRD/110

Simply Silent Contour 4 (100mm) Axial Extraction Fan

Installation & User Instructions: Model: e600s e600gf e700s e1000s e1000gf e1030gf/2/3 e1500gf/2/3

Internal/External Wall/Window Fan Range GX6. Installation and maintenance instructions Retain for future use

Wiring the fan correctly...

HOTLINE:

Residential Carbon Friendly Ventilation SAP Q Eligible. ventilation

YOUR SAFETY & INSTRUCTION MANUAL PLEASE READ CAREFULLY HAIR DRYER MODEL C80002

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

ProAction. Paper Shredder. Installation & User Instructions Please keep for future reference 903/1537

Unity CV2GIP Decentralised Mechanical Extract Ventilation (dmev) Installation Instructions

Trimbox Mixed Flow Fans. Product Manual. ventilation systems TP220T TP221T TP222T TP223T

KADO LUX LED EXHAUST FAN 200

Integra. Integra Plus EC MVHR. Installation & Commissioning. Stock Ref. N EC Integra Plus EC PLEASE RETAIN THESE INSTRUCTIONS WITH THE PRODUCT.

HS&S Alert No: 103 Date: 9 March 2017

Installation & User Instructions:

User Instruction Manual

MEV-DC. Continuous Mechanical Extract Ventilation Units Installation and Maintenance. Figure 3. Fixing screw hole.

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN

Autofill wall mounted water. boiler. Getting the best from your water. boiler. Please read and keep these instructions

KADO LUX 3-IN-1 HEAT LIGHT EXHAUST

isense & isense-ht 230V Flush Mounted Domestic Continuous Extract Fans

USER S MANUAL BUCKET FAN SERIES BUCKET FAN WHISPER SERIES

Wiring the fan correctly...

CMX-S. Company name: Contact: Tel: Central Mechanical Extract Ventilation (cmev) appliance. Installation and Operating Instructions

01 Safety. IMPORTANT Be sure to have read and understood these instructions before beginning the installation process.

Sentinel. Kinetic MVHR and Kinetic Plus MVHR. Operation & Monitoring. Stock Ref. N

WHHR125DC - Aera. Whole House Mechanical Ventilation with Heat Recovery - MVHR

User Manual for your GEH6017 & GEH9017 Cooker Hood

Paper Shredder. Installation & User Instructions Please keep for future reference 913/0153

Centrifugal extract and condensation control fans

Turbo Lite Corded Handheld Stick Vacuum

FAITH (dmev) 230V / 24V DC SELV Flush Mounted Domestic Continuous Extract Fans

Autofill counter top water boiler

identity installation & maintenance instructions customer/technical services guarantee

e Bath Fan with Light User s Guide

User and Installation Instructions C6R/75, C6R/100, C6R/105, C6R/125, C6R/130, D6R/100, D6R/125, D5R/100, D5R/125, D3R/100

CAUTION - READ THESE INSTRUCTIONS BEFORE USING THE MACHINE

10L Dehumidifier. Model Number: LDH V AC 50/60Hz 290W

Green Line CMX. Central Mechanical Extract Ventilation (cmev) appliance. Installation and Operating Instructions. Model: CMX

MEV SPIDER INSTALLATION GUIDE FOR ENGINEER / INSTALLER

A4 Laminator. Installation & User Instructions Please keep for future reference 908/6197

Academy The Straightener IM.indd 1 24/06/ :10. Instruction Manual LSHS16

Xpelair Simply Silent TM Contour Fan

LOW TEMPERATURE DEHUMIDIFIER DES 80 OWNER S MANUAL

e Heater/Exhaust Fan/Light User s Guide

VA 150 A, VA 150 P WINDOW EXTRACT FAN. Installation and Wiring Instructions V/1/50Hz

MAKING MODERN LIVING POSSIBLE INT INT EFIT 550. User Guide and Installation Manual. Danfoss Heating

100 FLUEBOOST

Easy Duct Tastic. User Guide. Model: Triumph Easy Duct Smart Switch Model: Sensation Easy Duct Smart Switch

s l it l on for Infrared Heaters

FLCH4R Garage and Utility Electric Heater

Ci95 ULTIMATE REM IFU Ci76_22L.indd 1 19:47: Guido Krölls ADVANCED CERAMIC. with REAL PEARL 8x smoother 5x longer lasting

PERFORMANCE SLIMMING BELT

Issue5 07/13 USERS MANUAL IN-LINE MIXED FLOW

BWT6.3GL Cooker Hood 60 cm Glass chimney hood

MRXBOX95-WALL. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Extract air.

Transcription:

Domestic AC Fans 230V Installation and Operating Guide eco 230V AC Base Models: ico eco15 72683501 ico15 72591501 ico30 72591601 ico60 72591701

ico Domestic Fan 230V Installation, Maintenance and Use ico Domestic Fans are available in 3 model sizes and can be fitted to a wall or ceiling. Each fan requires a suitable size hole through the wall or ceiling which connects into a duct venting to the outside. The external opening should be covered by a suitable external grill, available separately from Airflow Developments td. Airflow ico / ico eco Model Options 72683501 - eco15-100mm Axial Fan with maximum capacity of 19 l/sec. 72573602-15 -100mm Axial Fan with maximum capacity of 19 l/sec. 72591601-30 -100mm Mixed Flow Fan with maximum capacity of 32 l/sec 72591701-60 -150mm Mixed Flow Fan with maximum capacity of 72 l/sec The ico range can be used as a simple extract fan operated by a remote switch, or can be fitted with an internal control module, available separately to give a range of control options including timer, humidity, motion sensor, pull cord, trickle speed or combinations of these functions. Optional modules are available separately and can be fitted at the time of installation or retrofitted. The ico Fan has an IP X4 rating housing and is suitable for mounting in Zone 1 or 2 in bathrooms, toilets, kitchens, utility rooms and inside shower cubicles as defined in Section 701 BS7161:2008 (IEEE wiring standards, 17 th Edition ). They also comply with the latest Building Regulations. Do not place the ventilator near direct heat sources, e.g. radiant heaters, or where temperatures can exceed 40 C (104 F). Page 2 of 8

The Fan requires a 230V 50Hz single phase supply. Class II equipment. BS E 60417. An external 3A fuse is required for each fan unit. ote: Switches for fans should be selected and sited in accordance with BS7161:2008 All electrical installation to be carried out by an approved electrician in accordance with Part P U.K. Building Regulations and to the latest IEEE standards, or the appropriate regulations in the country of installation. AWAYS ISOATE THE POWER SUPPY UIT AD FA UIT FROM THE POWER SUPPY BEFORE REMOVIG THE COVER. Mechanical Installation ico Domestic Fan can be recessed in a wall or ceiling. A mounting skirt is provided for surface mounting the ico 30 and ico 60. To avoid the backflow of condensation into the fan in a ceiling installation it is good practice to fit a CODESATIO TRAP to the outlet duct of the fan. CODESATIO TRAP Ensure free running of the fan impeller and that flexible duct connections are not over tightened to the fan outlet spigot. Airflow recommend that rigid ducting is used instead of flexible ducting, this will ensure maximum performance Front Cover Removal UDO THE RETAIIG SCREW AT THE BOTTOM EDGE OF COVER USIG A SCREWDRIVER. The front cover fan has a bayonet type fitting. To remove, undo the retaining screw at the bottom edge of the cover using a screwdriver, then rotate the cover a few degrees anticlockwise and remove. To refit, reverse the above procedure. Page 3 of 8

Recessing Fans in the Wall The ico 15 and ico eco15 requires a 110mm diameter hole through the wall lined with a 100mm id (internal diameter) duct. The ico30 requires a 110mm diameter hole through the wall, counter bored 160mm to a depth of 75mm. The 110mm hole should be lined with a 100mm id duct. The ico60 requires a 160mm diameter hole through the wall, counter bored 190mm to a depth of 75mm. The hole should be lined with 150mm id duct. Surface Mounting Fans on the Wall When surface mounting the ico30 and ico60 the supplied mounting skirt should be used. The ico30 requires a 110mm diameter hole through the wall lined with a 100 mm id duct and the ico60 requires a 160mm diameter hole through the wall, lined with a 150 mm id duct Recessing Fans in the Ceiling POSSIBE CABE ROUTIG DUCT JOIST CEIIG PYWOOD When recessing fans in the ceiling, a plywood support (min 18mm thick) should be mounted between the ceiling joists. Fans should not be fitted to unsupported plaster board. Page 4 of 8

The ico 15 and ico eco15 requires a 110mm diameter hole through the ceiling. The fan should be fixed, with the screws provided, through the plaster board into the support. The ico30 will require a 160mm diameter hole and the ico60 a 190mm hole. Surface Mounting Fans on the Ceiling POSSIBE CABE ROUTIG DUCT JOIST MOUTIG SKIRT PYWOOD When surface mounting the ico30, the mounting skirt should be used. The ico30 requires a 110mm diameter hole through the ceiling and the ico60 a 170mm diameter hole. The surface mounted skirt to be fixed, with the screws provided, through the plaster board into the support. The fan is then fitted into the skirt. Where flexible duct is used the diameter must be maintained. Page 5 of 8

Electrical Installation All electrical installation to be carried out by an approved electrician in accordance with Part P U.K. Building Regulations and to the latest IEEE standards, or the appropriate regulations in the country of installation. ico Domestic Fans require a 230V 50Hz supply, it is double insulated so therefore does not require an earth. For fans mounted in Zones 1 & 2 as defined in section 701 BS7161:2008 Additional protection must be provided by a Residual current device (RCD) with a rated residual operating current not exceeding 30mA. Wiring with no control module fitted. RCD 3 AMP SWITCHED FUSE Optional Modules for ico and ico eco 230V Wiring for control modules with external switching A RCD 3 AMP SWITCHED FUSE S Wiring for control modules with no external switching B RCD 3 AMP SWITCHED FUSE Refer to instructions supplied with (optional) modules for further information. Page 6 of 8

Maintenance SAFETY FIRST: AWAYS ISOATE THE FA UIT FROM THE POWER SUPPY BEFORE REMOVIG THE COVER. Warranty only covers the fan, not the reinstallation of this if required. When installed according to these instructions the ico Domestic Fans are completely safe. The materials used do not constitute a hazard. The module covers are made of a flame retardant material. Cleaning The external housing of the fan can be wiped with a damp cloth. Do not use household cleaners containing abrasives. Cleaning of the internal parts such as the impeller should be carried out using a soft brush. ote: Always ensure that the fan unit is isolated from the power supply before inserting the brush into the impeller duct. ever clean any parts of the fan assembly by immersing in water or using a dishwasher. Trouble shooting Tip: Take care not to over tighten the duct connection to the fan spigot. This can result in restricting the free rotation of the impeller and a thermal overload of the motor could occur causing short term fan failure. In the event of this occurring loosen the duct connection so that the impeller rotates freely within the spigot. The motor is fitted with an automatic reset after approximately 15 minutes and will restart the fan when reconnected to the module controller and mains supply. Warranty Applicable to units installed and used in the United Kingdom. Airflow guarantees the ico, ico eco fan units and ico modules for 2 YEARS from date of purchase against faulty material or workmanship. Extended to 3 when registered @ airflow.com. Warranty only covers the fan, not the reinstallation of this if required. In the event of any defective parts being found, Airflow Developments td reserve the right to repair or at our discretion replace without charge provided that the unit: 1. Has been installed and used in accordance with the fitting and wiring instructions supplied with each unit. 2. Has not been connected to an unsuitable electrical supply. 3. Has not been subjected to misuse, neglect or damage. 4. Has not been modified or repaired by any person not authorised by Airflow Developments td 5. Has been installed in accordance with latest Building Regulations and IEEE wiring regulations. Airflow Developments shall not be liable for any loss, injury or other consequential damage, in the event of a failure of the equipment or arising from, or in connection with, the equipment excepting only that nothing in this condition shall be construed as to exclude or restrict liability for negligence. This warranty does not in any way affect any statutory or other consumer rights. Page 7 of 8

9041548 Issue 4 07/13 Range of Optional Modules Available Choose the 230V Module PCM Pull Cord: 72573602/B TM Adjustable Timer: 72612601/B HTM Humidity, Pull cord with Timer Overrun: 72687103/B PRTM Passive Infra Red with Timer Overrun: 72573903/B or 72687104/B PRHTM Passive Infra Red/Humidity/Timer: 72573901/B or 72687102/B CVM30 Continuous Ventilation ico30: 72631802 CV2 Continuous Ventilation: 72675701B DTM Delayed Timer start AC: 7265702B 2SHM 2 Speed /Humidity/ Pull Cord boost AC: 72675703B Choice of Anthracite, Sandstone, Chrome and Silver covers ico 15 cover Anthracite 52634503B ico 30 cover Silver 52634507B ico 15 cover Silver 52634504B ico 30 cover Sandstone 52634508B ico 15 cover Sandstone 52634505B ico 60 cover Anthracite 52634509B ico 15 cover Chrome 52634502B ico 60 cover Silver 52634510B ico 30 cover Anthracite 52634506B ico 60 cover Sandstone 52634511B UK Head-Office AIRFOW DEVEOPMETS imited Aidelle House, ancaster Road Cressex Business Park High Wycombe Buckinghamshire HP12 3QP United Kingdom Tel: +44 (0) 1494 525252 Fax: +44 (0) 1494 461073 Email: info@airflow.com Web: airflow.com Czech Republic AIRFOW UFTTECHIK GmbH o.s. Praha Hostýnská 520 108 00 Praha 10 Malešice Czech Republic Tel: +42 (0) 2 7477 2230 Fax: +42 (0) 2 7477 2370 Email: info@airflow.cz Web: airflow.cz Germany AIRFOW UFTTECHIK GmbH Postfach 1208 D-53349 Rheinbach Germany Tel: +49 (0) 222 69205 0 Fax: +49 (0) 222 69205 11 Email: info@airflow.de Web: airflow.de AIRFOW DEVEOPMETS imited reserve the right in the interest of continuous development to alter any or all specifications without prior notice. Page 8 of 8

Addendum 10/2016 The Building Regulations 2010, Statutory Instrument Part 9, paragraph 42, imposes a requirement that testing and reporting of mechanical ventilation performance is conducted in accordance with an approved procedure. Compliance with this requirement by an assessed and registered Competent Person should follow a Best Practice process and adopt air flow measurement, Method A The Unconditional Method using a suitable UKAS certified measuring instrument. Generically referred to as a Zero Pressure Air Flow Meter or Powered Flow Meter. Further information on this method is detailed in HBC Building Regulations Guidance ote G272a 10/13 and BSRIA A Guide to Measuring air flow rates document BG46/2015